the effect of beam depth on the shear behavior of...

11
Article Advances in Structural Engineering 2016, Vol. 19(11) 1769–1779 Ó The Author(s) 2016 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav DOI: 10.1177/1369433216649386 ase.sagepub.com The effect of beam depth on the shear behavior of reinforced concrete beams externally strengthened with carbon fiber–reinforced polymer composites Rajai Z Al-Rousan 1,2 and Mohsen A Issa 3 Abstract The primary objective of this article is to study the effect of beam depth on the performance of shear-deficient beams externally strengthened with carbon fiber–reinforced polymer composites. The investigated parameters include overall behavior up to failure, the onset of the cracking, crack development, and ductility. The experimental results showed that externally bonded carbon fiber– reinforced polymer increased the shear capacity of the strengthened reinforced concrete beams significantly depending on the vari- ables investigated. The use of carbon fiber–reinforced polymer composites is an effective technique to enhance the shear capacity of reinforced concrete beams. For the beams tested, as the depth of the reinforced concrete beams was increased from 225 to 450 mm which is equivalent to a/d ratio of 2.7–1.2, respectively, there was corresponding 15%–19% increase in contribution of the carbon fiber–reinforced polymer strips in terms of ultimate load. The impact of the beam depth is more pronounced on the ultimate load than the corresponding deflection of the control and strengthened beams. The results indicated that the beam depth has an influence on the angle at which primary cracking angle varied from 33, 44, 50, and 54 for beam of a/d of 2.7, 1.9, 1.5, and 1.2, respectively. If the shear crack crossed carbon fiber–reinforced polymer strips above its development length, the carbon fiber–reinforced polymer strips could not be expected to reach its ultimate strength and was thus only partially effective as observed in beams with different depths. Keywords beam depth, carbon fiber–reinforced polymer composites, externally, reinforced concrete beams, shear behavior, strengthened Introduction The deterioration of civil engineering infrastructures such as buildings, bridge decks, girders, offshore struc- tures, and parking structures is mainly due to aging, poor maintenance, corrosion of steel reinforcement, defects in construction/design, demand in the increased service loads, exposure to harmful environments and damage in case of seismic events, and improvement in the design guidelines. These deteriorated structures are deficient to take the load for which they are designed. A large number of structures constructed in the past using the older design codes in different parts of the globe are structurally unsafe according to the new design codes and hence need upgradation of the exist- ing structures. Also, increases in traffic volume, traffic loads, and corrosion-induced deterioration are necessi- tating significant expenditures to strengthen and reha- bilitate existing structures (Noel and Soudki, 2011). Of the 163,000 single-span concrete bridges in the United States, 23% are considered structurally deficient or functionally obsolete (Mabsout et al., 2004). The shear failure of a reinforced concrete (RC) beam is distinctly different from the flexural one in that the flexural is ductile in nature, whereas the shear one is brittle and catastrophic. When the RC beam is deficient in shear, or when its shear capacity is less than the flexural capacity after flexural strengthening, shear strengthening of the beam must be considered. It is critically important to examine the shear capacity of RC beams which are intended to be strengthened in flexure. Fiber-reinforced polymers (FRPs) have emerged as promising material for rehabilitation of 1 Department of Civil Engineering, Jordan University of Science and Technology, Irbid, Jordan 2 Department of Civil and Infrastructure Engineering, American University of Ras Al Khaimah, Ras Al Khaimah, United Arab Emirates 3 Department of Civil and Materials Engineering, The University of Illinois at Chicago, Chicago, IL, USA Corresponding author: Rajai Z Al-Rousan, Department of Civil Engineering, Jordan University of Science and Technology, PO Box 3030, Irbid 22110, Jordan. Email: [email protected]

Upload: dinhkien

Post on 07-Sep-2018

228 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

Article

Advances in Structural Engineering2016, Vol. 19(11) 1769–1779� The Author(s) 2016Reprints and permissions:sagepub.co.uk/journalsPermissions.navDOI: 10.1177/1369433216649386ase.sagepub.com

The effect of beam depth on the shearbehavior of reinforced concrete beamsexternally strengthened with carbonfiber–reinforced polymer composites

Rajai Z Al-Rousan1,2 and Mohsen A Issa3

AbstractThe primary objective of this article is to study the effect of beam depth on the performance of shear-deficient beams externallystrengthened with carbon fiber–reinforced polymer composites. The investigated parameters include overall behavior up to failure,the onset of the cracking, crack development, and ductility. The experimental results showed that externally bonded carbon fiber–reinforced polymer increased the shear capacity of the strengthened reinforced concrete beams significantly depending on the vari-ables investigated. The use of carbon fiber–reinforced polymer composites is an effective technique to enhance the shear capacity ofreinforced concrete beams. For the beams tested, as the depth of the reinforced concrete beams was increased from 225 to 450 mmwhich is equivalent to a/d ratio of 2.7–1.2, respectively, there was corresponding 15%–19% increase in contribution of the carbonfiber–reinforced polymer strips in terms of ultimate load. The impact of the beam depth is more pronounced on the ultimate loadthan the corresponding deflection of the control and strengthened beams. The results indicated that the beam depth has an influenceon the angle at which primary cracking angle varied from 33, 44, 50, and 54 for beam of a/d of 2.7, 1.9, 1.5, and 1.2, respectively. If theshear crack crossed carbon fiber–reinforced polymer strips above its development length, the carbon fiber–reinforced polymer stripscould not be expected to reach its ultimate strength and was thus only partially effective as observed in beams with different depths.

Keywordsbeam depth, carbon fiber–reinforced polymer composites, externally, reinforced concrete beams, shear behavior, strengthened

Introduction

The deterioration of civil engineering infrastructuressuch as buildings, bridge decks, girders, offshore struc-tures, and parking structures is mainly due to aging,poor maintenance, corrosion of steel reinforcement,defects in construction/design, demand in the increasedservice loads, exposure to harmful environments anddamage in case of seismic events, and improvement inthe design guidelines. These deteriorated structures aredeficient to take the load for which they are designed.A large number of structures constructed in the pastusing the older design codes in different parts of theglobe are structurally unsafe according to the newdesign codes and hence need upgradation of the exist-ing structures. Also, increases in traffic volume, trafficloads, and corrosion-induced deterioration are necessi-tating significant expenditures to strengthen and reha-bilitate existing structures (Noel and Soudki, 2011). Ofthe 163,000 single-span concrete bridges in the UnitedStates, 23% are considered structurally deficient orfunctionally obsolete (Mabsout et al., 2004).

The shear failure of a reinforced concrete (RC)beam is distinctly different from the flexural one inthat the flexural is ductile in nature, whereas the shearone is brittle and catastrophic. When the RC beam isdeficient in shear, or when its shear capacity is lessthan the flexural capacity after flexural strengthening,shear strengthening of the beam must be considered. Itis critically important to examine the shear capacity ofRC beams which are intended to be strengthened inflexure. Fiber-reinforced polymers (FRPs) haveemerged as promising material for rehabilitation of

1Department of Civil Engineering, Jordan University of Science and

Technology, Irbid, Jordan2Department of Civil and Infrastructure Engineering, American

University of Ras Al Khaimah, Ras Al Khaimah, United Arab Emirates3Department of Civil and Materials Engineering, The University of Illinois

at Chicago, Chicago, IL, USA

Corresponding author:

Rajai Z Al-Rousan, Department of Civil Engineering, Jordan University of

Science and Technology, PO Box 3030, Irbid 22110, Jordan.

Email: [email protected]

Page 2: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

existing RC structures and strengthening of the newcivil engineering structures because of their severaladvantages such as high strength-to-weight ratio, highfatigue resistance, flexible nature, ease of handling,and excellent durability. Therefore, the recent advance-ment of FRP composites as a repair and strengtheningmaterial for RC beams, slabs and columns in struc-tural engineering applications has increased over thepast 20 years (American Concrete Institute (ACI),2007; Bank, 2006; Cao et al., 2005; Chaallal et al.,1998; Khalifa et al., 1998; Triantafillou, 1998;Triantafillou and Antonopoulos, 2000). The non-corrosive properties and high strength-to-weight ratioof FRP materials make them a very viable repair mate-rial and can result in longer service life of structures(Noel and Soudki, 2011). The advancement of newmaterials and technologies has led researchers to inves-tigate various designs and materials to increase thestrength of shear critical RC beams (Ascione and Feo,2000; Garden and Hollaway, 1998; Sim et al., 2005;Taljsten and Elfgren, 2000; Yao et al., 2005). Variousmaterials, configurations, wrapping techniques, andmechanical anchors have been explored to increase thecapacity of existing RC members and postpone ordelay the debonding process in externally bonded FRPmembers (Adhikary and Mutsuyoshi, 2004;Bousselham and Chaallal, 2008; Bukhari et al., 2010;Chaallal et al., 2002; Chen et al., 2010, 2012; Chen andTeng, 2003; Deniaud and Cheng, 2001; Khalifa andNanni, 2000; Kim and Smith, 2009a, 2009b; Ortonet al., 2008; Quinn, 2009; Smith and Kim, 2008). Thebeam depth, shear span-depth ratio, and beam sizeparameters had a strong impact on the behavior of theRC beams strengthened in shear with FRP Strips(Islam et al., 2005; Leung et al., 2007; Li and Leung,2015).

It is observed from the existing literature that thepotential use of carbon fiber–reinforced polymer(CFRP) strips in strengthening the RC rectangularbeams is reported without taking into account theeffect of beam depth. Based on the critical review ofthe existing literature, the main objective of this workis to study the effect of beam depth on the shear beha-vior of RC beams externally strengthened with CFRPcomposites.

Description of experimental program

Ingredient properties

Concrete. All the specimens were made from the samebatch of normal weight concrete and conventional fab-rication and curing techniques were used. The maxi-mum size of coarse aggregate was 19 mm crushedlimestone. Type I Portland cement and admixture were

used for all concrete mixes. Table 1 shows the mixturedesign proportions of concrete used in this study. Theconcrete mix had a slump in the range of 75–125 mm.Twelve 150 mm 3 300 mm concrete cylinders werecast along with each group and cured in the moistureroom. The compressive strength of concrete f 0c wasdetermined by testing standard concrete cylinders thatwere taken from the same mix batch at the time oftesting the specimens.

Carbon fiber sheets. One type of carbon fiber sheet wasused in the research program depending on the manu-facturers. This type was the carbon fiber unidirectionalsheet in the form of tow sheet. The carbon fiber prod-ucts come in 500-mm-wide rolls of continuous fiberthat can be cut into appropriate lengths. The providedand tested property of the carbon fiber tow sheet isshown in Table 2.

Reinforced concrete beam details

Eight rectangular RC beams were casted and testedwith cross sections of 150 mm 3 225 mm, 150 mm3 300 mm, 150 mm 3 375 mm, and 150 mm3 450 mm and a total length of 1500 mm. The beamswere reinforced with 2f8 bars at the top and 3f15bars at the bottom and without stirrups for all the spe-cimens. The design choices were made to ensure thatshear failure would occur in the beams. Four beamswere tested as control beam without strengthening and

Table 1. Mixture design proportions of concrete.

Ingredients Mix proportions (for 1 m3)

Cement 357 kgCoarse aggregate 1026 kgFine aggregate 645 kgSilica fume 18 kgFly ash 71 kgWater 161 kgRB 1000 super plasticizer 90 fl ozMB-VR air-entraining 15 fl ozf 9c at 28 days 55 MPa

Table 2. Mechanical properties of CFRP.

Property Provided amount Tested amount

Ultimate strength 4275 MPa –Design strength 3790 MPa 3920 MPaYielding modulus 228 GPa 231 GPaUltimate strain 0.0168 mm/mm 0.017 mm/mmThickness 0.165 mm 0.165 mm

1770 Advances in Structural Engineering 19(11)

Page 3: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

four beams were strengthened with CFRP composites.Figure 1 shows the reinforcement and the CFRP stripconfigurations for all the beams.

The CFRP sheets were applied to four beams after28 days of concrete casting. The CFRP sheets/strips of

the required length were cut and bonded to the weband/or tensile face of the beams. The details and num-ber of layers of carbon fiber for all beam specimens areshown in Table 3. In the beam designation of Table 3,the first letter ‘‘B’’ indicates the beam specimen; 2.7,

Figure 1. Typical layout of the control and strengthened reinforced concrete shear beam.

Table 3. The details, ultimate load, and mode of failure of tested shear beam specimens.

Beamdesignation

h, mm d, mm a/d Type ofstrengthening

Ultimatedeflection,mm

Ultimateload, kN

Failure mode

B2.7N0 225 185 2.7 None 8.5 (0%) 129.9 (0%) Shear failure followed by 33�diagonal crack

B1.9N0 300 263 1.9 None 12.0 (0%) 217.5 (0%) Shear failure followed by 44�diagonal crack

B1.5N0 375 333 1.5 None 16.0 (0%) 253.5 (0%) Shear failure followed by 50�diagonal crack

B1.2N0 450 417 1.2 None 17.8 (0%) 411.4 (0%) Shear failure followed by 54�diagonal crack

B2.7U90ST1 225 185 2.7 Strip@ 90� U-wrap 15.2 (80%) 149.0 (15%) Shear failure followed by 33�diagonal crack and debonding ofCFRP sheets

B1.9U90ST1 300 263 1.9 Strip@ 90o U-wrap 17.5 (44%) 252.2 (16%) Shear failure followed by 44�diagonal crack, debonding ofCFRP sheets, and ripping ofconcrete

B1.5U90ST1 375 333 1.5 Strip@ 90� U-wrap 20.0 (25%) 300.2 (18%) Shear failure followed by 50�diagonal crack, debonding ofCFRP sheets, and ripping ofconcrete

B1.2U90ST1 450 417 1.2 Strip@ 90� U-wrap 21.5 (21%) 484.8 (18%) Shear failure followed by 54�diagonal crack, debonding ofCFRP sheets, and ripping ofconcrete

CFRP: carbon fiber–reinforced polymer.

Al-Rousan and Issa 1771

Page 4: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

1.9, 1.5, and 1.2 stand for the shear span over effectivedepth (a/d). The letters: N stands for no strengthened;U90 for 90� U-wrap, and ST for strip wrap followedby the number of layers of CFRP strips.

Test set-up and instrumentations

All specimens were tested as simply supported in a spe-cial designed built-up rigid steel frame. A hydraulic jackwas used to apply a concentrated load through ahydraulic cylinder on a spread steel beam to producetwo-point loading condition to generate a constantmoment region at mid-span. Three types of instrumentswere used in the tests: linear variable differential trans-former (LVDT), strain gages, and load cell. FourLVDTs were used: one to monitor the vertical displace-ment, the LVDT was located at mid-span; two to moni-tor the crack opening, the LVDTs were located atcritical shear stress on both sides; and finally, one tomeasure the concrete strain at top face. For each speci-men, at least three strain gages were attached directly tothe FRP strips to monitor the strain during loading. Aload cell was used to measure the applied load through-out the tests and a TDS 302 data acquisition system tocollect the data of the strain gages, LVDTs, and theload. During loading, the formation of cracks on thesides of the beams was also marked and recorded. TheRC shear beam test set-up is shown in Figure 2.

Experimental results and discussion

Mode of failure

All control specimens without shear reinforcementexhibited an initial flexural crack at the center of thespecimen and subsequent flexural cracks away fromthat section. As the applied load was increased, one ofthe flexural cracks extended into a diagonal crack nearone of the supports, or a diagonal crack formedabruptly at the mid height of the beam within theshear span area. After the formation of the diagonal

crack, failure occurred by splitting along the tensionreinforcement. The ultimate failure mode was shearfailure and the angle of the diagonal shear crack is var-ied from 33, 44, 50, and 54 for beam of a/d of 2.7, 1.9,1.5, and 1.2, respectively. A representative crackingpattern is shown in Figure 3.

Figure 4(a) shows the representative cracking pat-terns of strengthened tested beam (B2.7U90ST1). Theinitial flexural crack started at the center of the beamwithin the constant moment region at 34.2 kN.Beyond this load, cracks extended toward the topfiber, and additional flexural cracks were developedthroughout the beam length. At 112.5 kN, a 33-degreeangle shear crack developed independently of the exist-ing flexural cracks in the center of the shear span.With further load increase, the Strip No. 4 wasdebonded at 139.2 kN followed by the debonding ofStrip No. 3 at 142.8 kN. The beam failed successivelyat 149.0 kN after the debonding of Strip No. 5 asshown in Figure 4(a) and Table 3. Debonding of theCFRP strip is a delamination between the strip-adhe-sive-concrete at the strip-end region of the strength-ened beam. This failure was a result of the maximumstresses in the adhesive being not greater than thebonding strength between strip-adhesive-concrete atthe strip-end region.

Figure 4(b) shows the representative cracking pat-terns of strengthened tested beam (B1.9U90ST1). Theinitial flexural cracks started at 42.3 kN at the centerof the beam within the constant moment region.Beyond this load, cracks extended toward the topfiber. Additional flexural cracks were developedthroughout the beam length. At 124.5 kN, a 44-degreeangle shear crack developed independently of the exist-ing flexural cracks in the center of the shear span.With further increase in load, Strip No. 4 started todebond at 250.0 kN followed by the debonding ofStrip No. 5 at 251.0 kN. The beam failed successivelyin shear at 252.2 kN after the debonding of Strip No.2 which is closest to support point as shown in Figure4(b) and Table 3.

Figure 2. Test set-up for reinforced concrete shear beams.

1772 Advances in Structural Engineering 19(11)

Page 5: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

Figure 4(c) shows the representative cracking pat-terns of strengthened tested beam (B1.5U90ST1). Theinitial flexural cracks started at 51.6 kN at the centerof the beam within the constant moment region.Beyond this load, cracks extended toward the top fiber.Additional flexural cracks were developed throughoutthe beam length. At 133.4 kN, a 50-degree angle shearcrack developed independently of the existing flexuralcracks in the center of the shear span. With furtherincrease in load, Strip No. 4 started to debond at293.6 kN followed by the debonding of Strip No. 5 at300.2 kN. The beam failed successively in shear at300.2 kN as shown in Figure 4(c) and Table 3.

Figure 4(d) shows the representative cracking pat-terns of strengthened tested beam (B1.2U90ST1). Theinitial flexural cracks started at 84.5 kN at the center

of the beam within the constant moment region.Beyond this load, cracks extended toward the topfiber. Additional flexural cracking developed through-out the beam length. At 164.6 kN, a 54-degree angleshear crack developed independently of the existingflexural cracks in the center of the shear span. Withfurther increase in load, Strip No. 4 started to debondat 476.0 kN followed by the debonding of Strip No. 5at 484.8 kN. The beam failed successively in shear at484.4 kN as shown in Figure 4(d) and Table 3.

Ultimate load capacity

Figure 5(a) shows the normalized ultimate load andultimate deflection of the strengthened beams withrespect to the control ones with a depth of 225 mm.

Figure 3. A representative cracking patterns of control tested beams: (a) B2.7N0, (b) B1.9N0, (c) B1.5N0, and (d) B1.2N0.

Al-Rousan and Issa 1773

Page 6: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

Inspection of Figure 5(a) reveals that the ultimate loadcapacity of the strengthened beams increased by 69%,102%, and 225% with the increase in the beam depthby 33% (300 mm), 67% (375 mm), and 100%(450 mm), respectively. The impact of the beam depthon the ultimate load of the strengthened beams isequal to the control ones. Also, Figure 5(a) shows thatthe ultimate deflection of the strengthened beamsincreased by 42%, 64%, and 122% with the increasein the beam depth by 33% (300 mm), 67% (375 mm),and 100% (450 mm), respectively. While, the impactof the beam depth on the ultimate deflection of thestrengthened beams is equal to one-third the controlones with a percentage of 14%, 30%, and 41% for thebeam depth of 300, 375, and 450 mm, respectively. In

addition, inspection of Figure 5(b) reveals that the nor-malized ultimate load capacity of the strengthenedbeams with respect to the control beams is 15%, 16%,18%, and 18% for beams with a/d ratio of 2.7, 1.9,1.5, and 1.2, respectively. Whereas, the normalizedultimate deflection capacity of the strengthened beamswith respect to the control beams is 80%, 44%, 25%,and 21% for beams with a/d ratio of 2.7, 1.9, 1.5, and1.2, respectively.

Load–deflection behavior

Figure 6 shows the load–deflection curves for testedbeams. All strengthened beams exhibited almost linearload–deflection relationships up to the load of 129.9,

Figure 4. A representative cracking patterns of strengthened tested beams: (a) B2.7U90ST1, (b) B1.9U90ST1, (c) B1.5U90ST1, and(d) B1.2U90ST1.

1774 Advances in Structural Engineering 19(11)

Page 7: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

201.1, 222.8, and 389.2 kN that equals to the failureload of B2.7N0, B1.9N0, B1.5N0, and B1.2N0, respec-tively, beams. This indicates that the CFRP started tocarry the load after the formulation of the diagonalshear crack. Inspection of Figure 6 shows that the ulti-mate load capacity of the beams increased with theincrease or effective depth as well as the increase instiffness can be observed from the rotation angle ofthe elastic stage curve of the tested beams. In addition,Figure 6 shows that the ductility of the beam increasedwith the increase in beam depth which is the exact mir-ror of the mode of failure.

Concrete compressive strain

Figure 7 shows the relationship between the load andconcrete compressive strain for tested beams.

Inspection of Figure 7 revealed that the compressivestrain in the concrete increased with the increase in theeffective depth (d). Also, Figure 7 shows that the con-crete compressive strain of the beams increased withthe increase in effective depth. The strengthened RCbeam (B1.2U90ST1) CFRP sheet registered the higheststrain.

CFRP tensile strain

Figure 8 shows the relationship between the load andCFRP sheet tensile strain for tested beams. Accordingto Figure 8, the tension strain in the sheet was initiatedafter the diagonal shear crack starts to formulate atloads of 98.7, 157.9, 180.6, and 192.2 kN forB2.7U90ST1, B1.9U90ST1, B1.5U90ST1, andB1.2U90ST1 beams, respectively. Figure 8 also shows

Figure 5. The normalized ultimate load and deflection with respect to control beam (Pu: the ultimate load; Du: the ultimate deflection).

Figure 6. Load–deflection curves for tested beams. Figure 7. Load–concrete compressive strain curves of testedbeams.

Al-Rousan and Issa 1775

Page 8: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

that the development of strains becomes sluggisharound a load of 77.8 kN for B2.7U90ST1,B1.9U90ST1, and B1.5U90ST1 beams. Inspection ofFigure 8 reveals that the sheet tensile strain increasedwith the increase in effective depth (d). It is alsoobserved that the development of strain slows down asthe effective depth decreases. At ultimate load, the ten-sile strains on sheets were 3165, 7720, 8615, and9640 me for B2.7U90ST1, B1.9U90ST1, B1.5U90ST1,and B1.2U90ST1 beams, respectively, which is equiva-lent to 19%, 46%, 51%, and 57% of the ultimate ten-sile strain of FRP strips, respectively. These higherstrains of CFRP strips reflected the efficiency of theCFRP bonded length of beam depth in the strengthen-ing of shear-deficient beams.

Crack opening behavior

Figure 9 shows the relationship between the load andcrack opening for tested beams. According to

Figure 9, crack opening width started after the diago-nal shear crack was initiated at load 88.5, 109.4,137.4, 159.2, 98.7, 157.9, 180.6, and 192.2 kN forB2.7N0, B1.9N0, B1.5N0, B1.2N0, B2.7U90ST1,B1.9U90ST1, B1.5U90ST1, and B1.2U90ST1, respec-tively, after the formulation of diagonal shear crack.Figure 9 also shows that the development of crackwidth also becomes sluggish around 0.25 mm in allbeams. It can be observed that the crack developed ata slower rate with the increase in effective depth (d).At ultimate load, the ultimate crack width is 1.78,2.56, 2.81, 3.07, 1.14, 1.78, 2.43, and 2.71 mm forB2.7N0, B1.9N0, B1.5N0, B1.2N0, B2.7U90ST1,B1.9U90ST1, B1.5U90ST1, and B1.2U90ST1, respec-tively. Therefore, the B2.7U90ST1 strengthened beamshowed less crack width for the same load than theother beams.

Validation of experimental results with ACI model

The model proposed by the ACI Committee 440 (2008)is only applicable to RC beams externally reinforcedwith FRP materials. It is based on the classical formu-lation of shear strength for ordinary RC beams by add-ing the contribution of external shear reinforcement,that is

Vu =Vc +VS + gf Vf ð1Þ

with

Vc = 1:9ffiffiffiffiffif 0c

q+ 2500r

Vud

Mu

� �bwd ł 2

ffiffiffiffif 0c

pbwd ð2Þ

Vs =Ast ftyd

sð3Þ

Vf =Af Ef efed

sf

ð4Þ

In the above formulas, d is the effective depth of thebeam section, Mu/Vud represents the shear span todepth ratio a/d, and df = hf 2 d# is the effective depthof the external reinforcement, d# being the concretecover. Furthermore, efe is the effective tensile strain inthe FRP, Ef is the elastic modulus of FRP in the prin-cipal fiber orientation, and gf is a reduction factorequal to 0.95 for fully wrapped elements and 0.85 forbeams with two or three sides bonded. In equation (4),the effective FRP strain efe is assumed to be smallerthan the ultimate tensile elongation of the FRP com-posite efu, depending on the governing mode of failure(related to the shear strengthening configuration) andcan be computed as follows

Figure 8. Load–CFRP sheet tensile strain curve for testedbeams.

Figure 9. Load crack opening curves for tested beams.

1776 Advances in Structural Engineering 19(11)

Page 9: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

efe =0:004 ł 0:75efu for fully wrapped beamskvefu ł 0:004 for beams with two to three sides bonded

ð5Þ

where

kv =k1k2Le

11, 900efu

ł 0:75 ð6Þ

k1 =f 0c27

� �2=3

ð7Þ

k2 =

df�Le

dffor fully wrapped beams

df�2Le

dffor beams with two sides bonded

(ð8Þ

Le =23, 300

tf Ef

� �0:58ð9Þ

For purposes of comparison, the experimentalresults are compared with those of the ACI model. Itis clear that in the ACI model, the general design gui-dance is derived from the experimental data and theyare only applicable to external FRP reinforcement.The results of the experimental validation are dis-cussed below. Figure 10 shows a comparison of theexperimental results with the ACI model Vf,exp/Vf,ACI.The overall predictions by ACI and model also do notappear to be equally satisfactory with a mean Vf,exp/Vf,ACI value of 1.32 and a coefficient of variation(COV) of 25% for the ACI model. Therefore, the ACImodel, on the other hand, provides very conservativeresults. It is also important to take into considerationthat the ACI model is semi empirical in nature, with

important governing parameters derived from test datafor beams strengthened with FRP laminates, whereasthe ACI model cannot be applied in certain cases.

Conclusion

Based on the experimental results, the following con-clusions can be made:

1. The use of CFRP composites is an effective tech-nique to enhance the shear capacity of RCbeams. The externally bonded CFRP canincrease the shear capacity of the beam signifi-cantly by 15%–19% than that of the controlbeams, depending on the variables investigated.

2. The main failure is shear failure after debond-ing of more than two CFRP strips due to theformulation of diagonal shear crack. Testresults seem to indicate that this mechanismcan be prevented by providing a larger bondlength of CFRP strips in the beam from topside.

3. The results indicated that the beam depth has aninfluence on the angle at which primary crackingangle varied from 33, 44, 50, and 54 for beam ofa/d of 2.7, 1.9, 1.5, and 1.2, respectively.

4. The impact of the beam depth is more pro-nounced on the ultimate load than the corre-sponding deflection of the control andstrengthened beams.

5. The effective depth of the RC beams wasincreased from 185 to 417 mm which

Figure 10. The normalized experimental FRP shear force with respect to ACI model.

Al-Rousan and Issa 1777

Page 10: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

equivalent to a/d ratio of 2.7–1.2 resulted in adecrease in average interface bond stress and anincrease in the effective strain of the CFRPsheet at failure, which resulted in a higher shearcapacity as compared with that of the U-wrapped beams as well as delay or mitigate thesheet debonding from the concrete surface.

6. The inclination of the primary shear crackinfluenced the shear strength contribution ofthe external strengthening. As was demon-strated in this study, the shear crack angledetermined the number of CFRP strips inter-sected by the crack and whether or not anintersected CFRP strip was fully effective.

7. The results of the study show that the ACImodel provides very conservative results with amean of 1.32 and a COV of 25%.

Declaration of Conflicting Interests

The author(s) declared no potential conflicts of interest withrespect to the research, authorship, and/or publication of thisarticle.

Funding

The author(s) received no financial support for the research,authorship, and/or publication of this article.

References

ACI Committee 440 (2008) Design and Construction of Exter-

nally Bonded FRP Systems for strengthening Concrete

Structures (*ACI440.2R-08). Farmington Hills, MI: ACI,

p. 45.Adhikary BB and Mutsuyoshi H (2004) Behavior of concrete

beams strengthened in shear with carbon-fiber sheets.

Journal of Composites for Construction 8(3): 258–264.American Concrete Institute (ACI) (2007) Report on Fiber-

Reinforced Polymer (FRP) Reinforcement for Concrete

Structures. Farmington Hills, MI: ACI.Ascione L and Feo L (2000) Modeling of composite/concrete

interface of RC beams strengthened with composite lami-

nates. Composites Part B: Engineering 31(6–7): 535–540.Bank LC (2006) Composites in Construction: Structural

Design with FRP Materials. Hoboken, NJ: John Wiley &

Sons.Bousselham A and Chaallal O (2008) Mechanisms of shear

resistance of concrete beams strengthened in shear with

externally bonded FRP. Journal of Composites for Con-

struction 12(5): 499–512.Bukhari IA, Vollum RL, Ahmad S, et al. (2010) Shear

strengthening of reinforced concrete beams with CFRP.

Magazine of Concrete Research 62(1): 65–77.Cao SY, Chen JF, Teng JG, et al. (2005) Debonding in RC

beams shear strengthened with complete FRP wraps.

Journal of Composites for Construction 9(5): 417–428.

Chaallal O, Nollet M and Perraton D (1998) Shear strength-

ening of RC beams by externally bonded side CFRP

strips. Journal of Composites for Construction 2(2):

111–113.Chaallal O, Shahawy M and Hassan M (2002) Performance

of reinforced concrete T-girders strengthened in shear

with carbon fiber-reinforced polymer fabric. ACI Struc-

tural Journal 99(3): 335–343.Chen GM, Teng JG and Chen JF (2012) Shear strength

model for FRP-strengthened RC beams with adverse

FRP-steel interaction. Journal of Composites for Construc-

tion 17(1): 50–66.Chen GM, Teng JG, Chen JF, et al. (2010) Interaction

between steel stirrups and shear-strengthening FRP strips

in RC beams. Journal of Composites for Construction

14(5): 498–509.Chen JF and Teng JG (2003) Shear capacity of FRP-

strengthened RC beams: FRP debonding. Construction

and Building Materials 17(1): 27–41.Deniaud C and Cheng JJR (2001) Shear behavior of rein-

forced concrete T-beams with externally bonded fiber-

reinforced polymer sheets. ACI Structural Journal 98(3):

386–394.Garden HN and Hollaway LC (1998) An experimental study

of the failure modes of RC beams strengthened with pre-

stressed carbon composite plates. Composites Part B:

Engineering 29(4): 411–424.Islam MR, Mansur MA and Maalej M (2005) Shear

strengthening of RC deep beams using externally bonded

FRP systems. Cement & Concrete Composites 27(3):

413–420.Khalifa A and Nanni A (2000) Improving shear capacity of

existing RC T-section beams using CFRP composites.

Cement & Concrete Composites 22(1): 164–174.Khalifa A, Gold W, Nanni A, et al. (1998) Contribution of

externally bonded FRP to shear capacity of flexural mem-

bers. Journal of Composites for Construction 2(4):

195–203.Kim SJ and Smith ST (2009a) Behaviour of handmade FRP

anchors under tensile load in un-cracked concrete.

Advances in Structural Engineering 12(6): 845–865.Kim SJ and Smith ST (2009b) Shear Strength and Behaviour

of FRP Spike Anchors in Cracked Concrete. Sydney,

NSW, Australia: ICE Australia.Leung CKY, Chen Z, Lee S, et al. (2007) Effect of size on the

failure of geometrically similar concrete beams strength-

ened in shear with FRP strips. Journal of Composites for

Construction 11(5): 487–496.Li W and Leung CKY (2015) Shear span-depth ratio effect

on behavior of RC beam shear-strengthened with full-

wrapping FRP strip. Journal of Composites for Construc-

tion. DOI: 10.1061/(ASCE)CC.1943–5614.0000627.Mabsout M, Tarhini K, Jabakhanji R, et al. (2004) Wheel

load distribution in simply supported concrete slab

bridges. Journal of Bridge Engineering 9(2): 147–155.Noel M and Soudki K (2011) Evaluation of FRP postten-

sioned slab bridge strips using AASHTO-LRFD bridge

design specifications. Journal of Bridge Engineering 16:

839–846.

1778 Advances in Structural Engineering 19(11)

Page 11: The effect of beam depth on the shear behavior of ...aurak.ac.ae/publications/The-effect-of-beam-depth-on-the-shear... · behavior of reinforced concrete beams externally strengthened

Orton SL, Jirsa JO and Bayrak O (2008) Design considera-tions of carbon fiber anchors. Journal of Composites for

Construction 12(6): 608–616.Quinn KT (2009) Shear Strength of Reinforced Concrete

Beams with Carbon Fiber Reinforced Polymer (CFRP)

and Improved Anchor Details. Austin, TX: University ofTexas at Austin.

Sim J, Park C and Moon DY (2005) Characteristics of basaltfiber as a strengthening material for concrete structures.Composites Part B: Engineering 36(6–7): 504–512.

Smith ST and Kim SJ (2008) Shear Strength and Behaviour

of FRP Spike Anchors in FRP-to- Concrete Joint Assem-

blies. Winnipeg, MB, Canada: Multi Science PublishingCo Ltd.

Taljsten B and Elfgren L (2000) Strengthening of concretebeams for shear using CFRP-materials: evaluation of dif-ferent application methods. Composites Part B: Engineer-

ing 32(2): 87–96.Triantafillou TC (1998) Shear strengthening of reinforced

concrete beams using epoxy-bonded FRP composites.ACI Structural Journal 95(2): 107–115.

Triantafillou TC and Antonopoulos CP (2000) Design ofconcrete flexural members strengthened in shear withFRP. Journal of Composites for Construction 4(4):198–205.

Yao J, Teng JG and Chen JF (2005) Experimental study onFRP-to-concrete bonded joints. Composites Part B: Engi-

neering 36(2): 99–113.

Al-Rousan and Issa 1779