test grains as a novel diagnostic tool
DESCRIPTION
TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL. B.W. James, A.A. Samarian and W. Tsang School of Physics, University of Sydney NSW 2006, Australia [email protected] ICPP Sydney 2002. What is a dusty plasma?. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/1.jpg)
TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL
B.W. James, A.A. Samarian and W. Tsang
School of Physics, University of Sydney
NSW 2006, [email protected]
ICPP Sydney 2002
![Page 2: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/2.jpg)
What is a dusty plasma?
• a low temperature plasma containing small particles of diameters in nanometer and micrometer range
• particles acquire a net negative charge (at equilibrium floating potential)
• particles levitated in sheaths where electric force balances gravity
• particles can form liquid- and solid- like arrays (plasma or Coulomb crystal) which can undergo phase transitions
![Page 3: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/3.jpg)
Forces on dust particle in plasma sheath
E
vi
rf powered electrode
radius = acharge = Zd
sheathboundary
heq
hb
FE, Fth
Fg, Fi
ions
z
Figure 1: Schematic diagram of dust particle in plasma sheath
![Page 4: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/4.jpg)
Forces on a dust particle
• Electric force
• Gravity force
• Ion drag force
• Thermophoretic force
FE Zd E
Fg 4
3a3g
Fi a2nimiv i2 1
eZ d
amivi2
Fth 32
15
m
8Ta2
T
z
![Page 5: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/5.jpg)
where– a is particle radius– is particle density– Zde is charge on particle– mi is ion mass– ni is ion density– vi in ion velocity in sheath– Te is electron temperature– T is gas temperature– m is mass of gas atoms– is thermal conductivity of plasma
![Page 6: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/6.jpg)
Experimental arrangement
Dust particles
Grounded electrode
Powered electrode
Figure 2: Experimental chamber and image of test dust particles levitated above the electrode. The test grains are generated in the discharge (power up to 200W, pressure up to 1 torr) by electrode sputtering.
![Page 7: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/7.jpg)
Equilibrium position of dust particleUsing the force balance equation,
FE + Fg + Fi + Fth = 0 the equilibrium position has been calculated as a
function of radius a (see figure 3) using following assumptions– Vs ~ 60 V, linear variation of electric field in sheath– vi from sheath model– Te ~ 2 eV– R = 2 g cm-3
– dT/dz ~ 1-5 K cm-1 (varying with input power)– Zd calculated from OML theory
![Page 8: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/8.jpg)
Equilibrium position vs. radius
0
0,1
0,2
0,3
0,4
0,5
0 0,5 1 1,5 2 2,5 3
Dust radius, m
(hb-heq)/hb
Figure 3: Equilibrium height of dust particles above electrode heq, relative to height of sheath boundary hb as a function particles radius for several values of ion plasma frequency,
i = 106 s-1 (dashed) 5x106 s-1 (dotted), 107 s-1 (solid),
i 4nie2 / mi
![Page 9: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/9.jpg)
Alternative estimates of sheath width
0
0,5
1
1,5
2
2,5
3
0 2 4 6 8 10 12 14 16 18 20
h, mm
T, eV I, a.u.1
0.5
heq
Figure 4: Electron temperature Te (points with error bars) measured using
Langmuir probe; discharge emission (solid line); the dashed line shows the equilibrium position (heq =10.8 mm) of test grains (a~350 nm). Discharge
conditions: p = 90m Torr, P = 80 W.
![Page 10: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/10.jpg)
0
5
10
15
20
25
30
0 10 20 30 40 50 60 70 80 90 100
Pressure (mTorr)
hb(mm)
Position of sheath edge (Position of sheath edge (hhbb) vs pressure at different rf-input powers) vs pressure at different rf-input powers
– 35W
– 60W
– 100W
Sheath width as function of pressure
![Page 11: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/11.jpg)
Visualisation of rf sheath
• Sufficiently small particles cannot achieve force equilibrium in the sheath - the sheath becomes a particle-free region
• Particles occupy pre-sheath and positive column
• Provides a visualisation of the sheath-plasma boundary - see Figure 5
![Page 12: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/12.jpg)
Figure 5:The shape of the potential well above the confiningelectrode in a radio-frequency (rf) discharge with aprinted-circuit board electrode system (Cheung et al.,2002) was visualised using fine dust grains that weregenerated in the discharge. The well shape wasfound to depend strongly on the confining potential
QuickTime™ and aPhoto - JPEG decompressor
are needed to see this picture.
![Page 13: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/13.jpg)
Particle Particle Driving PadDriving Pad
ParticleParticleDispenserDispenser
Top GroundTop GroundElectrodeElectrode
Gas InletGas Inlet
RF Supply15MHz
AC PowerPin ElectrodesPin Electrodes
DC Power
Side ObservationSide ObservationWindowWindow
Top ObservationTop ObservationWindowWindow
dZ
svFsvFsma 2211 )()(
1s2s
a
1v2v
vavmnFnTn
2
3
4
Transient motion technique
where
)(rf
Top View
'
20 )2(
E
mfZD
0fWhere is the resonant frequency'EAnd is the electric field gradient
![Page 14: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/14.jpg)
Effect of hot electrons in sheath
Rd ~ h heq
eqhh
Figure 6: Square root of distance of particle from sheath edge as a function of particle radius
![Page 15: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/15.jpg)
![Page 16: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/16.jpg)
![Page 17: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/17.jpg)
Particle Data
Probe Data
Figure 7: Potential profile measured by a Langmuir probe, and by transient motion analysis
![Page 18: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/18.jpg)
Conclusions
• as particle radius decreases, equilibrium position moves closer to edge of sheath
• sufficiently small particles avoid sheath region, occupying pre-sheath and positive column. providing visualisation of sheath
• hot electrons affect equilibrium position• potential and electric filed profiles determined from transient
motion analysis
AcknowledgementsThis work is supported by the Australian Research Council and the Science Foundation for Physics within the University of Sydney
ReferencesA.A. Samarian and B.W. James, Phys Letters A, 287 (2001) 125F. Cheung, A. Samarian and B. James, Physica Scripta, T98 (2002) 143-5
![Page 19: TEST GRAINS AS A NOVEL DIAGNOSTIC TOOL](https://reader035.vdocuments.mx/reader035/viewer/2022062423/56814313550346895daf6586/html5/thumbnails/19.jpg)
Particle Data
Probe Data
Least Mean Square Fit for Particle Data
Least Mean Square Fit for Probe Data
Figure 8:Radial electric fieldderived from resultsin figure 7.