technical specifications · soundwave™ 2.1 delivers all the efficiencies professionals have...

5
Technical Specifications SOUNDWAVE 2.1 Fitting Software

Upload: others

Post on 30-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Technical SpecificationsSOUNDWAVE™ 2.1 Fitting Software

  • Improved Workflow, Enhanced Productivity

    SoundWave™ 2.1 delivers all the efficiencies professionals have come to expect from SoundWave 2.0 — AB’s signature

    fitting software, plus Neptune™ compatibility. By working directly with clinicians, AB developed SoundWave to help

    improve clinics’ workflow and enhance productivity.

    SOUNDWAVE™ 2.1

  • Equipment Minimum RequirementsOperating System Windows XP Home & Pro with SP3 Windows VISTA, Windows 7Memory 512 MB RAM 1028 MB RAMProcessor Intel Pentium 3 / 600 MHz P4/800MHz (32-bit) or any 64-bit processorHard Drive 1 GB 1 GBGraphical Resolution 1024x768 16 bit color (65535 colors) 1024x768 16 bit color (65535 colors)Communication Port COM port / 115200 bauds COM port / 115200 baudsFitting Platform SpecificationsLanguage C#.NETDatabase Server SQL through Microsoft SQL Express/SQL Server 2005, 2008 and 2008 R2Patient File ManagementDatabase Options Back up Restore Selectable patient filtering options Advanced sorting and filtering capability Reference implant registration capabilities for easy access to self-learning protocolsPatient File Options Import from versions 1.4.077, 1.4.098, 1.6.8, 1.6.9, and 2.x Delete (with automated export capability of the deleted patient file)Program Options Archive Upload programs from processors (compatible with previous versions of SoundWave)Programming FeaturesAutomated Routines Electrode impedance measurements Implant association (IntelliLink™) RF management (PoEM) with selectable target voltages Stimulation pulse width calculation (APW 1 & APW 2) Default automated T measurements (T = M / 10) Access to HiRes Fidelity 120™, ClearVoice™*Psychophysical Measurement Features/Options Stimulation of individual, groups or all electrodes Speech Burst™, tone burst and live stimulation Selectable interpolation option Sweep and balance optionsAvailable Coding Strategies CII/HiRes 90K™ HiRes-S with Fidelity 120™**, HiRes-P with Fidelity 120™**, HiRes™-S, HiRes-P, CIS (emulation), MPS (emulation) C1 (only with Harmony Processor) CIS, MPS, SAS

  • Processor Support CII/HiRes 90K™ Neptune™, Harmony™, Auria™, PSP, CII BTE, PBTE C1 Harmony Speech Enhancement Algorithm ClearVoice™* (with Harmony and Neptune through HiRes with Fidelity 120™**)Program Features/Options M adjustments (with/without stimulation) T adjustments (with/without stimulation) Sweep and Balance Gain (+/- 10 dB and pre-configured settings) Mixing ratios Display input IDR (from 20 to 80 dB) Frequency Range: 250 Hz to 8.7 kHz including external low frequency Volume range (up to +/- 100%) Sensitivity (+/- 10 dB) Manual pulse width setting including inter pulse intervals AGC Selectable manual RF Extended low frequency capabilities (250 Hz) Selectable multi-color LED functionality for Neptune and Harmony Multi-color LED functionality; 2 color for PSP and 3 color for Neptune and Harmony processors Selectable audible alarm (Neptune and PSP) T-Coil enabling option (for Harmony only), Sensitivity disabling option (Neptune only)Bilateral Capabilities Bilateral fitting window with access to all parameters in fitting window listed above Simultaneously download programs to processors Simultaneously run impedances and conditioning Ability to adjust M & T levels while stimulating Bilateral balance/sweep

    Other Measurement SpecificationsElectrode Conditioning Stabilizes electrode impedances showing progress Standard sets of impedance measurements alternating with 4-second bursts of conditioning Neural Response Imaging Single channel eCAP Biphasic stimulation (32 µs/phase) 30 Hz stimulation rate Artifact cancellation using alternate stimulation phases Default number of samples: 128 tNRI display on fitting windows

  • 028-M078-03 ©2011 Advanced Bionics, LLC and its affiliates. All rights reserved.

    For more information on the SOUNDWAVE 2.1 Fitting Software,

    please visit AdvancedBionics.com

    ***Pending regulatory approval in the United States. **Not approved for pediatric patients in the United States.

    GLOBAL HEADQUARTERSAdvanced Bionics, LLC

    28515 Westinghouse PlaceValencia, CA 91355 USA

    +1.877.829.0026+1.661.362.1400

    +1.661.362.1500 [email protected]

    MANUFACTURERAdvanced Bionics, LLC

    12740 San Fernando RoadSylmar, CA 91342 USA

    +1.877.829.0026+1.661.362.1400

    +1.661.362.1500 [email protected]

    INTERNATIONAL HEADQUARTERSAdvanced Bionics AGLaubisrütistrasse 28

    8712 Stäfa, Switzerland+41.58.928.78.00

    +41.58.928.78.90 [email protected]

    EU REPRESENTATIVEAdvanced Bionics SARL76 rue de Battenheim

    68170 Rixheim, France+33.3.89.65.98.00

    +33.3.89.65.50.05 [email protected]

    ASIA PACIFICAdvanced Bionics

    Asia Pacific LimitedSuite 4203, 42/F, Tower OneLippo Centre, 89 Queensway

    Hong Kong+852.2526.7668

    +852.2526.7628 [email protected]

    LATIN AMERICAAdvanced Bionics Sucursal Colombia

    Carrera 7 No. 83-29Oficina 902

    Bogota, Colombia+571.691.59.00/05/14

    +571.621.84.42. [email protected]