Technical Services Resource

Guide for DME/HME

Questions ?

Dial 877-337-7111

LCD: Centers for Medicare & Medicaid Services Page 5 of 16

http://www.cms.hhs.gov/mcd/viewlcd_pdf.asp?lcd_id=11446&lcd_version=53&contractor_id=140 3/15/2010

LCD Information

Beneficiaries may self-administer home based overnight oximetry tests under the direction of a Medi-

care enrolled Independent Diagnostic Testing Facility (IDTF). A DME supplier or another shipping en-

tity may deliver a pulse oximetry test unit and related technology, to a beneficiary’s home under the fol-

lowing circumstances:

1. The beneficiary’s treating physician has contacted the IDTF to order an overnight pulse oximetry

test before the test is performed.

2. The test is performed under the direction and/or instruction of a Medicare-approved IDTF. Because

it is the beneficiary who self-administers this test, the IDTF must provide clear written instructions

to the beneficiary on proper operation of the test equipment and must include access to the IDTF in

order to address other concerns that may arise. The DME supplier may not create this written in-

struction, provide verbal instructions, answer questions from the beneficiary, apply or demonstrate

the application of the testing equipment to the beneficiary, or otherwise participate in the conduct of

the test.

3. The test unit is sealed and tamper-proof such that test results cannot be accessed by anyone other

than the IDTF who is responsible for transmitting a test report to the treating physician. The DME

supplier may use related technology to download test results from the testing unit and transmit those

results to the IDTF. In no cases may the DME supplier access or manipulate the test results in any

form.

The IDTF must send the test results to the physician. The IDTF may send the test results to the supplier

if the supplier is currently providing or has an order to provide oxygen or other respiratory services to

the beneficiary or if the beneficiary has signed a release permitting the supplier to receive the report.

Oximetry test results obtained through a similar process while the beneficiary is awake, either at rest or

with exercise, may not be used for purposes of qualifying the beneficiary for home oxygen therapy.

Excerpt from the :

LCD for Oxygen and Oxygen Equipment (L11446) Top of page 5

Complete document available at link listed above.

System requirements

For FULL functionality VirtuOx requires Windows XP service pack 2

and a minimum of Intenet explorer 7.0, internet explorer which must be

set to not display pages saved in cache. The VirtuOx portal cannot be

used functionally with any other browser than Internet Explorer.

(Note that for initial installation the user MUST have an adminis-

trator logon otherwise you will need to contact your IT group or Help-

desk to gain access to one to install the device drivers and ActiveX con-

trol)

The Portal will work with some older systems however we cannot guar-

antee full functionality of features and can only offer limited computer

support.

Nonin/Respironics devices and OEM.

Windows XP, Windows Vista and Windows 7 all have known issues if

you are using a Non-Supported serial to USB adaptor. The only sup-

ported devices are the KeySpan USA-19US manufactured by TrippLite,

and the Model 1000USB Manufactured by Nonin.

V-Pod Devices:

Versions of windows older than XP sp2 may have limited function and

can be used short term, please contact VirtuOx Corporate Support for

Vpod Drivers used in Operating systems earlier than windows XP ser-

vice pack 2.

The VirtuOx Dashboard, How to read, how to use.

The Dashboard has 4 “Gadgets” sections Each will be covered by title.

Overnight Oximetry Order Statistics

This data will tell you at a glance:

Orders Pending- The total number of patients scheduled but not uploaded.

Orders Entered- the number of patients scheduled within the date range listed.

Orders Completed- the number of successfully uploaded tests within the date range.

Average days pending- calculated based on the average time per patient from the point scheduled to the day

uploaded. (Completed)

Sleep Study Candidates- the number of test results processed within the date range that that are recommended to

do a more in depth sleep study due to the information gathered by the Oximeter.

Home Sleep Test Order Statistics

This data will tell you at a glance:

Sleep Study Patients- those patients that have been sponsored by the DME for Sleep study with VirtuOx

HST Orders Completed- this is the number of studies completed within the date range.

HST CPAP Qualifiers- shows the number of patients recommended to CPAP therapy with the completed test

(within date range)

HST CPAP Delivered- The dme must enter the date that the patient was delivered CPAP (If Qualified) from the

Sleep Study Patients list.

HST O2 Qualifiers- the number of patients that have qualified for Oxygen via the Sleep Study.

HST O2 Delivered- shows the number of patients just recommended to Oxygen based on the Sleep Study.

Overnight Oximetry Completed Orders

Group 1 Qualifiers- the number of patients qualified for oxygen via any group 1 criteria via overnight Oximetry

(within date range)

Group 2 Qualifiers- the number of patients qualified for oxygen within the group 2 criteria via overnight Oxi-

metry (within date range)

Non Qualified- the number of patients not qualifying for oxygen based on either group 1 or group 2 criteria. (may

still recommend HST)

Borderline Qualifiers- the number of patients not qualifying by either criteria however close in range (Possible

recommend retesting Overnight Oximetry for longer test sample or better data)

O2 Delivered- these are patients the DME delivers oxygen to and notes on Oximetry test for patient. .

Pie Chart representation shows the data from Overnight Oximetry and compares group 1 to group 2 and Non

qualifiers by percentage

Yearly Order Trends Boxes (2 at bottom of Dashboard)

These display based on the year listed the number of Uploads made to the account within a given month for com-

parison to past data.

OXIMETRY CHECKLIST.

Patient Name: ________________________________________

Doctor Name: ________________________________________

Initials date time

1. Schedule test in VirtuOx ____ ____ _____ 2. Check diagnosis for validity ____ ____ _____ 3. Print and Fax RX to VirtuOx ____ ____ _____ 4. Print AOB for Patient ____ ____ _____ 5. Test and clear Oximeter ____ ____ _____ 6. Print instructions for patient ____ ____ _____ 7. Deliver Oximeter AND Docs ____ ____ _____ 8. Retrieve Docs and Oximeter ____ ____ _____ 9. Fax AOB to VirtuOx ____ ____ _____ 10. Upload results to website ____ ____ _____

11. Contact doctor regarding results and act!

Is this RX Valid for Oximetry?

A few things to keep in mind!

Before Faxing documentation the patient MUST be scheduled in Virtuox.

A valid RX Must have a few things to be considered valid.

1. The Doctors Name Printed Legibly.

2. The Patients Name Printed Legibly.

3. A Valid Diagnosis Code for Pulse Oximetry by IDTF (Please see Physicians

RX on website for complete Updated list.)

4. The Request for Overnight Oximetry OR one of the following Acceptable

variables of nomenclature.

Overnight Oximetry Overnight Pulse Oximetry Overnight Pulse Ox

O/N Pulse Ox Overnight SaO2 Test Overnight O2 Test

Overnight PO Overnight POX Nocturnal Oximetry

Nocturnal Pulse Oximetry Nocturnal Pulse Ox Nocturnal SaO2 Test

Nocturnal O2 Test Nocturnal PO Nocturnal POX

Sleeping Oximetry 24 hour O2 Test Overnight Noc Ox

Noc Ox Nocturnal O2 sat Sleeping o2 sat

Sleeping SaO2 Overnight O2 sat

Pulse Oximetry rest, exertion and Nocturnal

Overnight Oximetry on room air

Overnight oximetry on oxygen, cpap or Bipap

Pulse Oximetry rest, exertion and overnight

5. The Date the RX was Written

6. The Doctors Signature.

These 6 points on a single page constitute a valid RX.

REMEMBER!

ACCORDING TO GUIDELINES THIS DOCUMENT MUST BE FAXED TO

VIRTUOX BEFORE YOU SEND THE OXIMETER TO THE PATIENT!

Valid Vs Invalid Tests.

To be considered a valid test in VirtuOx Standard it must meet the fol-

lowing requirements and statements:

1. Reports must be a minimum of 30 minutes in length.

2. Reports must have an artifact time less than half or the total test

length.

3. If the artifact length subtracted from the total test length brings the

test duration below 30 minutes, this will also be considered an

invalid test.

4. No sessions may overlap in time. This is caused by equipment

malfunction or misuse by the patient. These tests cannot be

validated. It is the responsibility of the DME to identify this

situation and retest the patient.

5. No multiple sessions outside the date range the test was conducted

may be attached to the patient. It is the DME responsibility to

delete any questionable reports before setting the test conditions.

6. The test end time must be within 25 hours of start time or the test

will be considered invalid.

The VirtuOx system automatically rejects any test result that has previ-

ously been uploaded to your account. This protects you by not allowing

a patient to be medically diagnosed by data derived from another pa-

tient.

WHAT IF:

The Wrong Doctor is Showing on a report.

• First step is to notify the incorrect Doctor that he will be receiving a fax in error.

• Second step is to fill out the Report Change Request form.

• Re-verify that the RX is valid and signed by the Doctor.

• Verify that the AOB is valid and signed and dated by the Patient.

• Fax ALL THREE documents to the Fax Number at the bottom of the Report

Change Request Form.

• Once the form has been received and all documentation has been verified the

report will be edited to reflect the information listed on the RX. Not what is

written by the DME.

• The correct doctor will receive an direct fax and the DME will be able to view the corrected

report in their Archived results area once the correction has been validated.

(Please note that if for some reason our verification team finds the test is not billable at

this point the correction will NOT be made until the DME submits proper documentation as

instructed by our corrections team)

What IF: I Uploaded the wrong Oximeter to my patient.

(Please note that for reasons beyond our control VirtuOx cannot for any reason correct

Core Patient information on any test result.)

The following steps must be followed to recover from this error.

A= the patient uploaded to by mistake

B= the Patient whose data is actually on the Oximeter

1. Immediately notify the doctor listed on Patient A’s report (Incorrect Patient /

Incorrect Doctor) and let Him/Her know that the proper documents will

arrive soon.

2. Reschedule patient A so that once his/her Oximeter data is available there will

be a place to upload it to.

3. Verify that all documentation is re-faxed for the patient A to assure that the new

upload will be viewable.

4. Clear and Delete all data from the Oximeter. Patient B will need to be retested

to acquire valid data to upload. VirtuOx cannot accept uploads of Identical

Data more than once as a safeguard to misdiagnosis.

5. Deliver either the same Oximeter OR a new Oximeter to patient B.

6. Proceed as normally, these steps now have everything set to operate normally,

Patient A’s test must be performed within a 30 day period starting the day of

the mistake to avoid double billing.

WHAT IF: The wrong time and date show on my report

Before starting this process please read the following notice outlining what we can time/

date correct and what we cannot. The DME has the ability to delete any session at the

time they set the test conditions, at this stage the DME verifies that ALL sessions belong to

the patient.

1. VirtuOx cannot validate a result showing ANY overlapping sessions by date due to the

fact that there is no way to verify what session happened when. It is the DMEs respon-

sibility to verify that the device was sent out cleared and with the time and date set

properly and has sufficient battery life to conduct test.

2. Reports showing more than 3 dates cannot be validated and will likely contain data

from another patient.

If any of the above is the case and you have gone beyond the upload

stage that sets the test conditions, please re-schedule and retest the

patient.

1. Be certain that the patient has signed and dated the AOB. Any time

and date corrections will be made based on the information from this

document.

2. Verify that the RX is valid for the billing purpose. (Please see posted

list)

3. Fax the Report Edit Request form along with BOTH valid documents

to the fax number on the Request form (Faxing to any other number

can result in up to a 4 day delay in processing the request)

(Please note that all conditions and documentation must be valid for billing

purposes or your correction will NOT be made until the documentation

issues have been corrected)

WHAT IF:

The wrong test condition shows on my report

1. Please contact the Doctor the report is being faxed to and notify

him/her of the error and assure them that a corrected version will be

faxed in a short time.

2. Fill out a Report Edit Request form noting the Incorrect entry and the

Correct Entry in the proper places

3. Verify that the AOB and RX are both Valid AND complete.

4. Fax all three documents to the fax number on the Report Edit Request

Form. (Faxes to other numbers may not reach the corrections team within

the 24 hour limit)

5. Once our Document validation team has approved the documentation

the report will be edited and a new copy faxed to the Physician of

Record. The VirtuOx Database and archives will reflect the correction and

it will be available to print once the correction is Validated.

(Please note that all documentation must be valid for billing or your

correction will NOT be made until the documentation issues have been

corrected)

WHAT IF:

I uploaded to Standard but test belonged in Office.

Virtuox cannot in this case guarantee a reversal of billing or a free test. It is

the DME/HME responsibility to monitor the uploads made and therefore it is

the DME/HME that is responsible for any situations that arise.

Beyond 24 hours the billing has already been generated and may be beyond possibility to

reverse

The first thing to do is to Notify [email protected] with the Patients name and information.

Without this we will NOT be able to stop the billing cycle.

From that point follow the next steps in order to proceed.

1. Schedule the test in Office and do the upload normally

2. Notify the doctor of the mistake and make sure he ignores the test he will be faxed ,

the Office side of VirtuOx reads differently than the Standard side.

Let the Patient know that they may be receiving a bill and NOT to ignore it, they must contact

YOU so you may get back to VirtuOx to rectify and confirm the billing had been cancelled and

that no further processing will occur.

This situation requires notes in the patient file outlining the situation because it may require fu-

ture follow-up. Make certain to keep track of anyone you spoke to in VirtuOx billing and print

out any email instructions given and note the action on your part.

Patient Retest Checklist for DME use.

If there is less than 30 minutes of data on a test, No data on a test, or the data on the oximeter is a Duplicate of

information already Uploaded to another patient the system should return the Patients name to your “Upload

Results” queue. If this is the case Please skip to step “5”

In the case that the Doctor or DME wishes to conduct a Retest the following rules

and procedures must be followed OR the DME/Doctor should EXPECT delays in

obtaining their results. Not following this procedure will create confusion causing

delays.

1. Please Notify VirtuOx via Email of the Pending Retest by Emailing Tech-

[email protected] with: The Reading ID of the test. and the reason for

Retesting.

2. Notify Doctor (if necessary) to disregard the results he will be receiving due

to a whatever reason they are bad, (Short, to much artifact, etc.)

3. Reschedule the patient using the “Schedule Test” selection in VirtuOx. The

system will prompt you to select either a “New” or a “Re-Test” once all of

the demographics are entered.

4. Proceed to retest and upload new result for patient.

BE CERTAIN THAT ALL DOCUMENTATION IS VALID AND ACCEPTED

BY OUR VALIDATION TEAM BEFORE RESCHEDULING A TEST.

Who Do I need to talk to? We would LOVE to speak to you. We understand that you

need the answers to your questions in the fastest way possi-

ble. If the answers to your questions are not contained in

this guide Please contact us using the following methods for

fastest service keep in mind that we are just a few qualified

individuals servicing many of you, allow us to assist as

many as possible by using the methods below for contact.

Upload issues:

877-337-7111 Opt 1

Home Sleep Testing Issues:

[email protected]

RX / AOB issues:

[email protected]

Orders or Device sales:

[email protected]

Uploading Vpod Devices PAGE 1.

First step is to confirm that the Individual has already installed both the CP210X and ActiveX drivers and knows

their com port If not please see section regarding DRIVER INSTALLATION and return to this reference when

completed.

VPOD W HD

Make sure that the Device is Plugged in and turned on The VPOD W HD will show a Probe Off message if this is

the case. Be certain that the Upload cable turns to the RIGHT of the device and falls toward the Buttons on the

VPOD W See Illustration. (Probe Off does not show in Picture)

Once this is confirmed, Navigate to VirtuOx and select “Upload Results”

• From “Upload Results” you will need to select the patient that the Individual had scheduled earlier by double

clicking the notepad and pencil next to the name.

• Select the Device being uploaded, in this case the VPOD Wrist HD and click the next button

• At this point you will need to accept the terms and conditions by placing a check mark and your Initials in the

proper locations and again clicking on the Next button.

• On many computers the default com port that will show is 1 or 2, at this point the individual will need to select

the com port showing the Silicon Labs CP210X in their Device manager (See Finding Com Ports if Nec)

• Re confirm that the device shows Probe off on the screen and click on the Connect button. If actually

connected the computer will show a percentage and the Oximeter will show Numbers rapidly rising on the

screen.

• Once the Oximeter reaches 100% and transfers to the server If everything on the oximeter is a good date

(within 30 days) and not a duplicate of data already uploaded to your account the page will automatically

forward itself to step 4. If the website gives you a message that says the time and date may have been set

incorrectly, please pay EXTREMELY close attention to the dates and times on the reports generated. In

certain cases the results may be deemed invalid and it is the DMEs responsibility to know how to proceed.

If there are any questions please see the reference on Valid Versus Invalid Tests.

• Once you have verified the test results and selected the proper test condition for each session click on the next

button to advance to step 5 and generate the report.

• You should see your reports listed at the bottom of the page in sets of three, If you do not see them please take

note of any message in that general area that will let you know what the issue may be and give

instructions on how to move forward. This Information will be LOST if you navigate away from this

page.

Uploading Vpod Devices PAGE 2.

Vpod Handheld HD V1 and V2

Advise individual to make sure that the Device is plugged into the computer but left off, Be certain that the ONLY

cable being plugged into the Vpod Handheld series has Grey, blue or light purple color. ALL OTHER CABLES

WILL DAMAGE THE OXIMETER IN SOME WAY. (See Pictures below)

A. from “Upload Results” you will need to select the patient that the Individual had scheduled earlier by

double clicking the notepad and pencil next to the name.

B. select the Device being uploaded, in this case the VPOD Handheld and click the next button.

C. at this point you will need to accept the terms and conditions by placing a check mark and your Initials in

the proper locations and again clicking on the Next button.

D. On many computers the default com port that will show is 1 or 2, at this point the individual will need to

select the com port showing the Silicon Labs CP210X in their Device manager (See Finding

Com Ports if Nec)

E. At this point press the power button and wait for the device to show probe off and click on the Connect

button. If actually connected the computer will show a percentage and the Oximeter will show

Numbers rapidly rising on the screen.

F. Once the Oximeter reaches 100% and transfers to the server If everything on the oximeter is a good date

(within 30 days) and not a duplicate of data already uploaded to your account the page will

automatically forward itself to step 4. If the website gives you a message that says the time and

date may have been set incorrectly, please pay EXTREMELY close attention to the dates and

times on the reports generated. In certain cases the results may be deemed invalid and it is the

DMEs responsibility to know how to proceed. If there are any questions please see the reference

on Valid Versus Invalid Tests.

G. Once you have verified the test results and selected the proper test condition for each session click on the

next button to advance to step 5 and generate the report.

H. You should see your reports listed at the bottom of the page in sets of three, If you do not see them please

take note of any message in that general area that will let you know what the issue may be and

give instructions on how to move forward. This information will be LOST if you navigate away

from this page.

Error messages on my Oximeter Dialogue

Listings here are for all known error messages on all supported Oximeters and in

some cases come from the manufacturers Guides.

VPOD W HD Error codes and Explanations.

E13- The current the device is receiving is less than 1.1 volts

Solution: REPLACE THE BATTERY

E1- Is a malfunction of the SPO2 Data and is Often a sign of a Bad Probe.

Solution: Switch Probe with a known working one and see if the Error code

follows the Probe or follows the Device. If the error follows the Probe, the

probe will need to be replaced. If the error stays with the device please sub-

mit the device for RMA.

E2- Failure to store data.

Solution: this device will need to be Cleared via the VirtuOx website, to

format the Memory which has for some reason corrupted. If the error per-

sists (VERY RARE) the unit will need to be submitted for RMA

Prob Off- This is not an error,

this merely says that the device is on and no sensor is plugged in, if

there is a sensor plugged in and the wire to the finger probe turns to the

right please submit for RMA.

SEN OFF- this is not an error.

This means that the patient needs to place the probe on their finger in the

proper manner.

Vpod HandHeld HD Error Codes and Explanations

E1- Firmware and or Programming memory damaged or courrupt. (Rare)

Solution: Clear the device via the VirtuOx website if possible, If error per-

sists Please submit for RMA

E2- Data Memory damaged and or corrupt.

Solution: Clear the device via the VirtuOx website if possible, if error per-

sists please submit for RMA

E7, E3, E4 or E5.- Probe Damaged.

Solution: Please test with alternate probe to assure that there is not an addi-

tional issue. Please replace Finger Probe.

E6- crystal Oscillator damaged (Rare)

Solution: Please submit the device for RMA.

E9- Real Time Clock damaged.

Solution: Please submit the device for RMA.

E10- Eeprom Damaged

Solution: Please submit the device for RMA.

Prob Off- This is not an error,

this merely says that the device is on and no sensor is plugged in, if

there is a sensor plugged in and this still shows please submit for RMA.

SEN OFF- this is not an error.

This means that the patient needs to place the probe on their finger in the

proper manner.

Finding Com Ports:

For Win 2000, XP, and Vista. (Please contact VirtuOx Tier 3 for WIN 7)

To find out which com port you need to use you need to know 2 things for certain. The type of device

you are using AND the type of connection you are using.

For 9pin (rs232, serial) devices:

check to confirm that the cable connects DIRECTLY to the PC without using any Adaptive devices or

cables.

the exceptions to this rule will ONLY be for the Keyspan USA-19HS (see Adaptive

Devices Dialogue) and the VPOD Handheld cable which is a direct interface not an

actual rs232 adaptor cable (9 pin end will be Grey, Blue or Purple), and the Model

1000USB By Nonin (Will say “Nonin” on front)

Many computers having direct 9pin ports on the back of the computer have more than one, they should

be labeled please note which one the upload cable is connected to

(1 or 2) as this will be the com port used for upload. In the case that the Serial port is on an add on card

please see notes regarding that situation below.

For Vpod Devices, add on serial cards and all Adaptive Devices:

Access the “Start” Button at the bottom left hand corner of the screen and select “Settings” or “Control

Panel”, We are looking for the Control panel to proceed.

Once the control panel window is opened you need to look for an entry called “System”

(You may need to look at the left hand side of the window and select “Change to Classic View” to see

this list properly)

Once you locate the “System” Icon click on it and another small window will open. Please select the

“Hardware” tab from the selection presented.

From the “Hardware” tab, select the button labeled “Device Manager” this will open yet another listing.

Once the Device Manager is opened, look about 2 thirds of the page down to locate the entry labeled

“Ports (Com & LPT)” click on the plus sign next to the entry.

This will display all “Connected” devices (or Hardware Ports in the case of standard RS232). From this

point we are looking for the following supported entries.

1. Silicon Labs Cp210X USB to UART Bridge (Com “X”) for VPOD

2. Keyspan USB Serial Port (Com “X”) for Nonin/Resp

3. USB Serial Port (Com “X”) for Nonin/Resp

4. An IDE serial port adaptor in the case of a hardware upgrade to RS232.

In Each case a device must be hooked to the unit to see the Com port and Driver. Please take note of the

Com Port for your device(s) this will be a permanent com port for upload to THIS computer.