tec ma 1535 program manual

95
PRINTED IN JAPAN TEC Electronic Cash Register MA-1535-2 SERIES Document No. EO3-11102 Original Jan., 2003 (Revised ) Programming Manual

Upload: ramiro-gonzalez

Post on 23-Jun-2015

4.060 views

Category:

Technology


28 download

TRANSCRIPT

Page 1: Tec ma 1535  program manual

PRINTED IN JAPAN

TEC Electronic Cash Register

MA-1535-2 SERIES

Document No. EO3-11102 Original Jan., 2003

(Revised )

Programming Manual

Page 2: Tec ma 1535  program manual

EO3-11102

TABLE OF CONTENTS

Page

1. INTRODUCTION ........................................................................................................ 1- 1

1.1 Main Features............................................................................................................... 1- 1

2. SPECIFICATIONS...................................................................................................... 2- 1

3. RAM CLEAR, DATA CLEAR, STATUS CLEAR........................................................ 3- 1

3.1 RAM Clear .................................................................................................................... 3- 1 3.2 DATA Clear................................................................................................................... 3- 2 3.3 STATUS Clear .............................................................................................................. 3- 2

4. PROGRAMMING OPERATIONS ............................................................................... 4- 1

4.1 Basic Key Functions ..................................................................................................... 4- 2 4.2 Character Entry Method ................................................................................................ 4- 3 4.3 Condition Required for Programming Operations.......................................................... 4- 5 4.4 RAM Allocation Setting ................................................................................................. 4- 6 4.5 SFKC (Selective Function Key Code) Programming ..................................................... 4- 8 4.6 TAX System Programming........................................................................................... 4-11 4.7 EFT Programming........................................................................................................ 4-12 4.8 Store Message and Commercial Message Programming (Submode 1) ....................... 4-15 4.9 Cashier Code and Name Programming (Submode 2) .................................................. 4-17 4.10 Department Table Programming (Submode 3)............................................................. 4-20 4.11 PLU Table Programming (Submode 4) ........................................................................ 4-23 4.12 Time Setting or Adjustment (Submode 5)..................................................................... 4-27 4.13 Date Setting or Adjustment (Submode 6)..................................................................... 4-28 4.14 Media Tender Key Setting (Submode 8) ...................................................................... 4-28 4.15 Financial Report Item Name Programming (Submode 9) ............................................. 4-30 4.16 Print Line Item Name Programming (Submode 10)...................................................... 4-33 4.17 Print Item on Reports Setting (Submode 11)................................................................ 4-36 4.18 Tax Table Programming (Submode 12) ....................................................................... 4-38 4.19 Department Group Name Programming (Submode 13) ............................................... 4-41 4.20 Display Upper-Row Message Programming (Submode 17) ......................................... 4-42 4.21 System Option Programming (Submode 18)................................................................ 4-49 4.22 Endorsement (or France Check Print) Message Programming (Submode 22) ............. 4-53 4.23 Link-PLU Table Programming (Submode 25)............................................................... 4-54 4.24 PLU Preset-Code Key Setting (Submode 27) .............................................................. 4-55 4.25 PLU Group Programming (Submode 29) ..................................................................... 4-55 4.26 Advertisement Message Programming (Submode 31) ................................................. 4-57 4.27 Report Header Name Programming (Submode 32) ..................................................... 4-59 4.28 Function Key (Combination Key) Setting (Submode 34) .............................................. 4-62 4.29 PLU Cashier Report Setting (Submode 35).................................................................. 4-63 4.30 %+ and %- Preset Rate Setting (Submode 36) ............................................................ 4-63 4.31 Foreign Currency Exchange Rate Setting (Submode 37)............................................. 4-65 4.32 + (Amount Charge) and - (Amount Discount) Preset Setting (Submode 38)................. 4-66

Page 3: Tec ma 1535  program manual

EO3-11102

Page

4.33 Manager Pass Code Programming (Submode 39) .......................................................4-68 4.34 Network Terminal No. Setting (Submode 40)................................................................4-68 4.35 COM Port Setting (Submode 41) ..................................................................................4-69 4.36 In-Store Marking Bar Code Programming (Submode 42)..............................................4-70 4.37 Register No. Setting (Submode 43) ..............................................................................4-71 4.38 Line Feed Value of Endorsement Message (Submode 46)...........................................4-71 4.39 Rounding Process Setting (Submode 47) .....................................................................4-72 4.40 Date Format Setting (Submode 49) ..............................................................................4-72 4.41 Printer Cutting Setting (Submode 51) ...........................................................................4-73 4.42 Store Coupon, Vender Coupon, Bottle Return Taxable Status Programming

(Submode 53)...............................................................................................................4-73 4.43 Food Stamp Programming (Submode 54) ....................................................................4-74 4.44 Age Limit Setting (Submode 55) ...................................................................................4-75 4.45 Tare Table Setting (Submode 56).................................................................................4-76 4.46 General Unit Weight Setting (Submode 57) ..................................................................4-76 4.47 Media Tender Key Setting 2 (Submode 58) ..................................................................4-77 4.48 EFT Timer and Status Setting (Submode 59) ...............................................................4-78 4.49 PLU Stock Loading or Changing (Submode 90) ...........................................................4-79

5. PROGRAMMED DATA VERIFICATION.....................................................................5- 1

5.1 Programmed Data Verification in BLIND Mode..............................................................5- 1 5.2 Programmed Data Verification in X or SET Mode ..........................................................5- 2

CAUTION! 1. This manual may not be copied in whole or in part without prior written permission of TOSHIBA

TEC. 2. The contents of this manual may be changed without notification. 3. Please refer to your local Authorised Service representative with regard to any queries you may

have in this manual.

Copyright © 2003 by TOSHIBA TEC CORPORATION All Rights Reserved 570 Ohito, Izunokuni-shi, Shizuoka-ken, JAPAN

Page 4: Tec ma 1535  program manual

1. INTRODUCTION EO3-11102

1.1 Main Features

1- 1

1. INTRODUCTION This programming manual for TEC Electronic Cash Register MA-1535-2 Series is provided for salespersons, field engineers and other support personnel. 1.1 Main Features < Hardware > • Display: 10-digit 7-segment and 10-digit alphanumeric display

The alphanumeric display indicates PLU name and machine status. • 3 ports of RS-232C: PC, Scanner, EFT, etc. can be connected. • Expansion RAM: Up to 16Mbit Expansion RAM for rich RAM allocation can be attached. • Keyboard: Normal type keyboard < Software > • Scanning function: Source marking and In-store marking are available. • Up to 24,000 PLUs: PLUs by using expansion RAM: 24,000 PLUs (standard: 5,000 PLUs) • 4 Tax memory: 4 Add-on Tax

Page 5: Tec ma 1535  program manual

2. SPECIFICATIONS EO3-11102 (Revision Date: Aug. 26, 2004)

2. SPECIFICATIONS

2- 1

2. SPECIFICATIONS < Hardware > SIZE: 410 mm (width) x 430 mm (depth) x 335 mm (height)

(including rubber feet) WEIGHT: 12.5 Kg POWER REQUIREMENT: AC 117V±10%, 60Hz±10%, 0.46A AC 220~230V±10%, 50/60Hz±10%, 0.24A AC 240V±10%, 50/60Hz±10%, 0.20A (It differs depending on destination.) BATTERY: Type ------------------------------------------------- Lithium battery Back-up duration --------------------------------- 6 months (in case of full charge) Charge method ----------------------------------- Inserting the power plug into an outlet Full charge time----------------------------------- 48 hours or more AMBIENT TEMPERATURE: 0°C to 34°C RELATIVE HUMIDITY: 10% to 80% (No condensation) PRINTER: Model------------------------------------------------ MT-51 (EPSON) Print method --------------------------------------- Line thermal dot printing Number of stations------------------------------- 2 stations (receipt and journal) Print speed----------------------------------------- 52 mm/second Printable digits ------------------------------------ 24 digits/line on both receipt and journal Character size------------------------------------- 1.67 mm (width) x 4.17 mm (height) Line space ----------------------------------------- 5.21 mm Character components-------------------------- 12 (width) x 24 (height) dots

(including 2-dot spacing in column) Paper roll (receipt and journal) ---------------- 57.5±0.5 mm (width) x max. 80 mm (diameter) Paper feed method------------------------------- Friction method Receipt cut method ------------------------------ Auto cut

Page 6: Tec ma 1535  program manual

2. SPECIFICATIONS EO3-11102 (Revision Date: Aug. 26, 2004)

2. SPECIFICATIONS

2- 2

< Software > Number of department: Max. 99 departments (standard: 30 departments) Number of PLU: Max. 24,000 PLUs (standard: 5,000 PLUs) Number of cashier: Max. 40 cashiers (standard: 10 cashiers) TAX memory: 4 Add-on TAX Memory balance: See below. GT (Grand Total) = Sum of Daily GS (Gross Sale) NET GT = Sum of Daily All-media Sales GS (Gross Sale) = (Sum of Positive Depts.) + (Sum of Taxes) + (%+) + (Item

Correct) + (Void) + (All Void) + (%- on Line Items) + (Amount Discount on Line Items) + (Store Coupon) + (Returned Merchandise) + (Negative Mode Total) + (Negative Tax)

Net Sale with Tax = (Sum of All Depts.) + (Sum of Taxes) + (%+) = (GS) – (Item Correct) – (Void) – (All Void) – (Sum of Negative

Depts.) – (%- on Line Items) – (Amount Discount on Line Items) – (Store Coupon) – (Returned Merchandise) – (Negative Mode Total) – (Negative Tax)

All-media Sales = (Net Sale with Tax) – (%- on Subtotal) – (Amount Discount on Subtotal) + (Positive HASH Depts.) + (Negative HASH Depts.) – (Vendor Coupon) – (Bottle Return)

= (Cash Sales) + (Check Sales) + (Sum of All Other Media Sales) Sum of Hourly Range Sales = Net Sale with Tax (US balance) Sum of Hourly Range Sales = Net Sale without Tax (Canada balance)

NOTE: (Sum of All Depts.) = (Sum of Positive Depts.) + (Sum of Negative Depts.) but excluding HASH Depts.

Page 7: Tec ma 1535  program manual

3. RAM CLEAR, DATA CLEAR, STATUS CLEAR EO3-11102

3.1 RAM Clear

3- 1

3. RAM CLEAR, DATA CLEAR, STATUS CLEAR

3.1 RAM Clear If the ECR becomes completely inoperative due to battery discharge or malfunction of the program memory, the RAM Clear operation must be carried out. When the RAM Clear is operated, all memory stored in the RAM will be cleared. (i.e., the programmed data and the sales data) In the clearing process, the designated zero-amount format is reset. Also “Initial Data” and “Initial Status” for respective programming items are automatically reset. 1. Use the S key to turn the Control Lock to “BLIND ”. 2. Depress the following Numeric keys according to the type of keyboard. 3. Depress the [AT/TL] key. 4. A RAM Clear receipt is issued. NOTE: When the RAM clear operation is performed, the condition “after all sales data reset” is

obtained, just as “Status Clear” and “Data Clear”. Therefore, no Reset Report should be taken for starting any programming operation.

CAUTION! This clear operation deletes all programmed data and sales data stored in the memory of the ECR. (i.e., the register goes back to initial status.)

Numeric Key Type of Keyboard [3] [9] Normal Type Keyboard

������������������������

<285 5(&(,37

7+$1. <28

������������������������

���������� �����

5$0�&

���� �����70

CAUTION! 1. When setting up the MA-1535 for the first time, charge the ECR for 48 hours or more by

plugging the power cord into an AC outlet. 2. When using the MA-1535 unelectrified for 1 month or more, charge the ECR for 48 hours or

more by plugging the power cord into an AC outlet. 3. If the MA-1535 just unpacked or unelectrified for 1 month or more doesn’t perform normally

at the power on, perform a RAM Clear, charge the ECR for 48 hours or more and then retry.

Page 8: Tec ma 1535  program manual

3. RAM CLEAR, DATA CLEAR, STATUS CLEAR EO3-11102

3.2 DATA Clear

3- 2

3.2 DATA Clear Performing the DATA Clear operation will clear only the sales data accumulated in the memory of the ECR (report memory), however, the programmed data will not be cleared. By this operation, all sales data including non-resettable totals and counters, Reset Report Counts, and Receipt Consecutive No. are cleared. 1. Use the S key to turn the Control Lock to “BLIND ”. 2. Depress the [3] key (Numeric key) and then the [AT/TL] key. 3. A DATA Clear receipt is issued. NOTE: When the DATA clear operation is performed, the condition

“after all sales data reset” is obtained, just as “Status Clear” and “Data Clear”. Therefore, no Reset Report should be taken for starting any programming operation.

3.3 STATUS Clear Performing the STATUS Clear operation will clear an error and the key locked condition, however, the sales data and the programmed data will not be cleared by this operation. When the STATUS Clear is operated to clear a key locked condition during sale, the sale item data that has already been entered for the current sale will be cleared. The STATUS Clear operation obtains the condition “after all sales data reset” which is required for some programming operations, but this operation will not affect any sales data. This condition is obtained by taking reset reports. In case you do not want to reset the sales data such as in business hours, this function is effective. Depending on the programming item, sales data should be reset instead of STATUS Clear to keep consistency between programmed data and sales data. The STATUS Clear can be performed in 2 methods shown below. < Method 1 > 1. Use the S key to turn the Control Lock to “BLIND ”. 2. Depress the [0] key (Numeric key) and then the [AT/TL] key. 3. A STATUS Clear receipt is issued. < Method 2 > 1. Remove the power code of the ECR from the wall outlet. 2. Use the S key to turn the Control Lock to “BLIND ”. 3. Plug in the power code and turn the power ON. 4. A STATUS Clear receipt is issued.

������������������������

<285 5(&(,37

7+$1. <28

������������������������

���������� �����

67$786�&

���� �����70

CAUTION! This clear operation deletes all sales data of any operation sequence stored in the memory of the ECR.

������������������������

<285 5(&(,37

7+$1. <28

������������������������

���������� �����

'$7$�&

���� �����70

Page 9: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4. PROGRAMMING OPERATIONS

4- 1

4. PROGRAMMING OPERATIONS Table of Programming Operations

Operation Control Lock Position Submode Page

Basic Key Functions --- --- 4- 2 Character Entry Method --- --- 4- 3 Condition Required for Programming Operations --- --- 4- 5 RAM Allocation Setting BLIND --- 4- 6 SFKC (Selective Function Key Code) Programming BLIND --- 4- 8 TAX System Programming BLIND --- 4-11 EFT Programming BLIND --- 4-12 Store Message and Commercial Message Programming SET 01 4-15 Cashier Code and Name Programming SET 02 4-17 Department Table Programming SET 03 4-20 PLU Table Programming SET 04 4-23 Time Setting or Adjustment SET 05 4-27 Date Setting or Adjustment SET 06 4-28 Media Tender Key Setting SET 08 4-28 Financial Report Item Name Programming SET 09 4-30 Print Line Item Name Programming SET 10 4-33 Print Item on Reports Setting SET 11 4-36 Tax Table Programming SET 12 4-38 Department Group Name Programming SET 13 4-41 Display Upper-Row Message Programming SET 17 4-42 System Option Programming SET 18 4-49 Endorsement (or France Check Print) Message Programming SET 22 4-53 Link-PLU Table Programming SET 25 4-54 PLU Preset-Code Key Setting SET 27 4-55 PLU Group Programming SET 29 4-55 Advertisement Message Programming SET 31 4-57 Report Header Name Programming SET 32 4-59 Function Key (Combination Key) Setting SET 34 4-62 PLU Cashier Report Setting SET 35 4-63 %+ and %- Preset Rate Setting SET 36 4-63 Foreign Currency Exchange Rate Setting SET 37 4-65 + (Amount Charge) and – (Amount Discount) Preset Setting SET 38 4-66 Manager Pass Code Programming SET 39 4-68 Network Terminal No. Setting SET 40 4-68 COM Port Setting SET 41 4-69 In-Store Marking Bar Code Programming SET 42 4-70 Register No. Setting SET 43 4-71 Line Feed Value of Endorsement Message SET 46 4-71 Rounding Process Setting SET 47 4-72 Date Format Setting SET 49 4-72 Printer Stamp Setting SET 52 4-73 Store Coupon, Vender Coupon, Bottle Return Taxable Status Programming SET 53 4-73 Food Stamp Programming SET 54 4-74 Age Limit Setting SET 55 4-75 Tare Table Setting SET 56 4-76 General Unit Weight Setting SET 57 4-76 Media Tender Key Setting 2 SET 58 4-77 EFT Timer and Status Setting SET 59 4-78 PLU Stock Loading or Changing X or Z 90 4-79

Page 10: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.1 Basic Key Functions

4- 2

Programming Operations are performed in “BLIND ” position or in “SET” position of the Control Lock. When you turn the Control Lock to “BLIND ” or “SET” position, the letter “S” in “BLIND ” mode or the letter “P” in “SET” mode is displayed on the leftmost column of the 10-digit Alphanumeric Display.

4.1 Basic Key Functions 1) Main keys [#/NS] ------------------ Used to enter the Program Submode No., Address data, Item data. Used to end the entire Program Submode Sequence. [ST] , [AT/TL] -------- Used to enter the Address No., Item Code. Used to end the Item data entries. 2) [C] key

• When the program data has finished to be printed, the [C] key cannot clear it. If you correct the program data, re-enter the data.

• Before the program data is printed, the [C] key can clear it. (except in the SFKC programming operation)

3) [ITEM CORR] key When you enter incorrect settings, depressing the [ITEM CORR] key can return the display to the

previous item setting. 4) To clarify the operation flow, definitions of keys of the ECR keyboard are as shown below. | | ------- Selective numeric value which is entered through the Numeric keys. [ ] -------- Depression of the function key. xxxx ---------- Fixed numeric value which is entered through the Numeric keys. Fixed

Page 11: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.2 Character Entry Method

4- 3

4.2 Character Entry Method Character Entry Method is to set characters by entering Character Code. This method is allowed on the ECR keyboard.

Page 12: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.2 Character Entry Method

4- 4

Character Setting Operation Key layout required at character setting is shown below. (Keys of bold characters are used at programming operation.) As character entry method, the Character Codes shown on the previous page are used basically. The above shadowed keys are used for character code entry. To enter numeric rows and columns, the Ten Keys on the keyboard are used. To enter alphabetic rows and columns A to F, the shadowed keys a to f are used, respectively. When entering character codes, enter row code and then column code. Therefore, one character should consist of two codes. • To set a regular-sized character, enter Row code and then Column code.

Example) To set “A”, enter [4] [1]. To set “n”, enter [6] [e]. To set “ä”, enter [e] [e].

• To set a blank instead of a character, enter [2] [0]. • To set a double-sized character, enter [f] [f] and then enter Row code and the Column code.

Example) To set “Drink”, “D” in double-sized, and “rink” in regular-sized; [f] [f] [4] [4] [7] [2] [6] [9] [6] [e] [6] [b] D r i n k

To set “Drink ”, all in double-sized; [f] [f] [4] [4] [f] [f] [7] [2] [f] [f] [6] [9] [f] [f] [6] [e] [f] [f] [6] [b] D r i n k The keys of SPACE and big-letter alphabets are used to enter spaces and alphabets in big letter directly from the keyboard instead of character code entry.

f #/NS E J O T Y SPACE

e C (Clear) D I N S X :

d 7 8 9 C H M R W ,

c 4 5 6 B G L Q V .

b 1 2 3 A F K P U Z

a 0 00 . AT/TL

Page 13: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.3 Condition Required for Programming Operations

4- 5

4.3 Condition Required for Programming Operations “CONDITION” is given at the top of each programming operation. The ECR must satisfy this condition to perform programming operations. There are two types of conditions: “Any time outside a sale”

It means that the programming operation is allowed when a sale is finalized before going into any other sale entry. “After------ reset”

It means that the designated reset report must be taken before entering the programming operation. Attempting operations without taking the report will cause an error. However, the condition “After------ reset” doesn’t mean “immediately after------ reset”. After the designated reset report is taken, performing the programming operations in the SET, X, or Z mode is within the condition “After------ reset”. And the operations are still allowed. On the contrary, after the designated reset report is taken, entering sales data relating to the report data in the REG, or - mode will cause the programming operation not to be allowed. And the same reset report must be taken. Thus the condition “After------ reset” indicates that all sales data relating to the report data must be zero (except non-resettable memory data). Because of this “CONDITION” requirement, the report data will be protected from any inconsistencies of sales data entered in the period from a resetting of the report to another resetting of the same report next time.

Page 14: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.4 RAM Allocation Setting

4- 6

4.4 RAM Allocation Setting The type of ECR, the Numbers of Departments, PLUs, and Cashiers can be set in this submode. After a RAM clear Control Lock: BLIND 01 [#/NS] |Type of ECR| [AT/TL] |Number of Departments| [AT/TL] Max. 2 digits |Number of PLUs| [AT/TL] Max. 5 digits |Number of Cashiers| [AT/TL] Max. 2 digits [AT/TL] * Value to be set for the Number of Departments, the Number PLUs and the Number of Cashiers: Case 1: Without PLU accumulation

Item (Number of:)

Default Value (auto-set a RAM Clear)

Value range when Standard Memory is used

Value range when 4Mbit Expansion Memory is used

Value range when 12Mbit Expansion Memory is used

Departments 30 1 to 99 1 to 99 1 to 99

PLUs 5,000 0 to 6,168 0 to 12,336 0 to 24,000

Cashiers 10 0 to 40 0 to 40 0 to 40

Case 2: With PLU accumulation

Item (Number of:)

Default Value (auto-set a RAM Clear)

Value range when Standard Memory is used

Value range when 4Mbit Expansion Memory is used

Value range when 12Mbit Expansion Memory is used

Departments 30 1 to 99 1 to 99 1 to 99

PLUs 5,000 (NOTE 3) 0 to 4,440 0 to 8,880 0 to 17,760

Cashiers 10 0 to 40 0 to 40 0 to 40

NOTES: 1. Even when a large area remains to be unallocated in the RAM, setting of any item

cannot exceed its value range specified in the table above. 2. When you enter incorrect values, depressing the [C] key will return the display to the

previous item. 3. With PLU accumulation, 5,000 is automatically set after a RAM clear, however, the

number of PLUs can be set up to 4,440 when the Standard Memory is used.

OPERATION

CONDITION

(See * for the value of each item.)

1 digit (0 or 1) 0: without PLU accumulation (Default) 1: with PLU accumulation

Page 15: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.4 RAM Allocation Setting

4- 7

Example) To allocate the RAM as follows; Expansion Memory: None Type of ECR: without PLU accumulation Number of Departments: 30 Departments Number of PLUs: 3,000 PLUs Number of Cashiers: 10 cashiers Control Lock: BLIND 01 [#/NS] 0 [AT/TL] (Type of ECR) 30 [AT/TL] (Number of Departments) 3000 [AT/TL] (Number of PLUs) 10 [AT/TL] (Number of Cashiers) [AT/TL] (To complete this program.)

���������� �����

66 ����

������ 0(025< 2. ������'(37�751 �����'(37�35* ���'(&$6+,(5�35* ���$�'(37�6$/( ���$�&$6+,(5�6$/( ��'��(1'�%$6( ��%��3/8�67$57 �����3/8�(1' �)���

3/8�7<3( �'(37 ��3/8 ����&$6+,(5 ��

���� �����70

Page 16: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.5 SFKC (Selective Function Key Code) Programming

4- 8

4.5 SFKC (Selective Function Key Code) Programming SFKC Programming is to determine the keyboard layout with the required keys. This operation must be performed first before any other programming operation. If the RAM Clear is performed prior to the SFKC programming, program only the keys that require changes from the SFKC in the Standard Keyboard which has been set by the RAM Clear operation automatically. (For Standard Keyboards, see Page 4-10.) After all Z & GTZ reports, or after RAM Clear, DATA Clear or STATUS Clear Control Lock: BLIND 20 [#/NS] 10 |SFKC| [Key] Fixed 20 |Department No.| [Key] Fixed Max. 2 digits (1 to 99)* 3 096 [Key] Fixed Fixed 500 |Media Tender Key No.| [Key] Fixed 1 digit (2 to 9)** [#/NS] STEP 1. Enter 20 and depress the [#/NS] key. This operation declares on the SFKC Programming.

STEP 2. Enter [1] [0] , SFKC (see SFKC Table on Page 4-9), and then depress a key which requires the key name of the SFKC. Repeat these operations until all required keys are set with their own SFKCs. Each key of the keyboard must correspond to one SFKC.

STEP 3. Enter [2] [0] , Department No. (1 to 99)*, and then depress a key to be the Department key. Repeat these operations until all required keys are set with their own Department keys.

STEP 4. Enter [3] and [0] [9] [6] , and then depress a key to be the PLU Preset-Code key. Repeat these operations until all required keys are set with their own PLU Preset-Code keys.

STEP 5. Enter [5] [0] [0] , Media Tender Key No. (2 to 9)**, and then depress a key to be the Media Tender key. Repeat these operations until all required keys are set with their own Media Tender keys.

STEP 6. Depress the [#/NS] key to end the SFKC Programming operation. * The Department keys should be set within the Number of Departments which were set in RAM

Allocation Setting. ** The Media Tender Key No.1 has already been set to the [AT/TL] key.

By allocating the Media Tender Key No. 8 to CREDIT and the Media Tender Key No. 9 to DEBIT, the EFT function will be available.

NOTE: If “9999” is entered as SFKC, the key will be dead. (V2 and after)

OPERATION

CONDITION

Department Key

A key that requires the SFKC function.

Refer to the SFKC table. (See NOTE below.)

A key that requires the SFKC function.

A key that requires the SFKC function.

A key that requires the SFKC function.

Repeat

Repeat

Repeat

Repeat

PLU Preset-Code Key

Media Tender Key

Page 17: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.5 SFKC (Selective Function Key Code) Programming

4- 9

SFKC Table

SFKC Key Name 11 000 (Triple-zero) 12 Reserved 13 PLU (Price-Look-Up) 14 %- (Percent Discount) 15 %+ (Percent Charge) 16 - 17 + 18 VOID (Void) 19 ITEM CORR (Item Correct) 20 RTN MDSE (Returned Merchandise) 22 PRICE 1 23 PRICE 2 24 PRICE 3 25 RA/LOAN (Received-on Account/Loan) 26 PO/PICK-UP (Paid-Out/Pick-Up) 27 CURRENCY (Foreign Currency) 28 DEPT SHIFT (Department Shift) 29 READ (Read) 30 TAX 1/M (Tax 1 Modifier) 31 TAX 2/M (Tax 2 Modifier) 32 TAX 3/M (Tax 3 Modifier) 33 TAX 4/M (Tax 4 Modifier) 34 TAX EX (Non-Tax) 35 JOURNAL PRINT (Thailand specification) 36 TAX DISPLAY (Columbia specification) 37 VALI DATE 38 ALL VOID (All Void) 39 ADD PLU (PLU Add) 40 CHECK No. (Check Number) 41 FUNCTION 1 42 FUNCTION 2 43 FUNCTION 3 44 FUNCTION 4 45 FUNCTION 5 46 FUNCTION 6 47 FUNCTION 7 48 FUNCTION 8 49 FUNCTION 9 50 FUNCTION 10 51 GST/M (GST Modifier) 52 RECEIPT ISSUE (Receipt Post-issue) 53 PRICE 54 EAN 56 MANUAL CARD # 57 OFF LINE AUTH 58 POST AUTH 59 SPLIT PRICE 60 S.CPN (Store Coupon)

SFKC Key Name 61 V.CPN (Vendor Coupon) 62 BTR (Bottle Return) 63 FS/M (Food Stamp Modifier) 64 FS TL/TEND (Food Stamp Total/Tender) 65 HOLD/RECALL (Hold/Recall) 66 ID CHECK 67 SCALE 68 TARE 69 TARE2 70 LC OPEN (V2 and after)

Page 18: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.5 SFKC (Selective Function Key Code) Programming

4-10

Standard Keyboard (Auto-set by RAM Clear) --- Normal Type Keyboard ---

NOTE: The numbers at the bottom of each key are shown as map code.

LOG RECEIPT

0

BTR

1

HOLD/ RECALL

2

#/NS

3 RF JF DP 1

4 5 DP 6

6 7 DP 11

8 9

DP 16

10

DP 21

11

DP 26

12

RECEIPT ISSUE

13

ALL VOID

14

PO

15

C

16 17

X/TIME

18 DP 2

19 20 DP 7

21 22 DP 12

23 24

DP 17

25

DP 22

26

DP 27

27

CUR

28

(-)

29

R/A

30

7

31

8

32

9

33 DP 3

34 35 DP 8

36 37 DP 13

38 39

DP 18

40

DP 23

41

DP 28

42

RTN MDSE

43

%-

44

TAX/EX

45

4

46

5

47

6

48 DP 4

49 50 DP 9

51 52 DP 14

53 54

DP 19

55

DP 24

56

DP 29

57

VOID

58

READ

59

TX1/M

60

1

61

2

62

3

63 DP 5

64 65 DP 10

66 67 DP 15

68 69

DP 20

70

DP 25

71

DP 30

72

ITEM CORR

73

PLU

74

TX2/M

75

0

76

00

77

.

78

ST

79 80

AT/TL

81 82

CHECK

83 84

CHARGE 85 86

CPN

87

NOTES: 1. FCxx: Function Key DPxx: Department Key PLU: PLU Preset-Code Key TDxx: Media Tender Key 2. For the Keys not described in the SFKC

Table ([LOG RECEIPT] , [#/NS] , [RF] , [JF] , [C] , [X/TIME] , [ST] , [AT/TL] , [.] , [0] , [00] , and [1] to [9] ), they cannot be programmed.

���������� �����

66 ����

��� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! )&����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! '3����� ���! 3/8��� ���! 7'����� ���! 7'����� ���! 7'��

���� �����70

Map code

Page 19: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.6 TAX System Programming

4-11

4.6 TAX System Programming TAX System for the ECR can be set in this submode. After all Z & GTZ reports, or after RAM Clear, DATA Clear or STATUS Clear Control Lock: BLIND 30 [#/NS] 1 |TAX System| [AT/TL] [#/NS] Fixed 1 digit (1 to 4) NOTES: 1. After the RAM Clear, the TAX System is set to US Break as standard. 2. By performing this programming, Tax Table Programming (Submode 12) will be reset. Example) To set the TAX System as follows; TAX System: US Break Control Lock: BLIND 30 [#/NS] 11 [AT/TL] [#/NS]

OPERATION

CONDITION

1: US Break (Default) 2: Canadian (General) 3: Canadian (Tax on tax) 4: Canadian (Ontario)

���������� �����

66 ����

7$; %$/$1& ��

���� �����70

Page 20: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming

4-12

4.7 EFT Programming For EFT function, the following 4 settings should be programmed and the following 5 operations can be performed here. Before performing 4.7.2 Dial In Load Command Sending , 4.7.6 Dial Out Load Command Sending , 4.7.7 Network List Output , 4.7.8 Local Total Report Output , and 4.7.9 Clear Current Batch , you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41) . 4.7.1 PIN Pad Selection The use of PIN Pad and the type can be selected here. Anytime outside a sale Control Lock: BLIND 40 [#/NS] |Type of PIN Pad| [AT/TL] [#/NS] 4.7.2 Dial In Load Command Sending The Dial In Load Command will be sent to the EFT terminal by the operation below. Before performing this operation, you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41) . Anytime outside a sale Control Lock: BLIND 41 [#/NS] [AT/TL] 4.7.3 Telephone Number Setting Anytime outside a sale Control Lock: BLIND 42 [#/NS] |Telephone Number| [AT/TL] [#/NS] NOTE: The [0] to [9] , [00] , and [.] keys only can be used. The value “0” is set as a default.

OPERATION

CONDITION

���������� �����

66 ����

3,1 3$' �

���� �����70

OPERATION

CONDITION

OPERATION

CONDITION

1 digit (0, 3, or 4) 0: Not used 3: DUKPT Debit 4: NOVA Debit (Default)

���������� �����

66 ����

3+21(� ����������

���� �����70

Max. 25 digits (See NOTE below.)

Page 21: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming

4-13

4.7.4 Host ID Number Setting Anytime outside a sale Control Lock: BLIND 43 [#/NS] |ID Number| [AT/TL] [#/NS] NOTE: The value “00000000” is set as a default. 4.7.5 Dialing System Setting Anytime outside a sale Control Lock: BLIND 44 [#/NS] |Dialling System| [AT/TL] [#/NS] 4.7.6 Dial Out Load Command Sending By this operation, the Telephone Number, Host ID Number and Dialing System programmed will be sent to the EFT terminal. Before performing this operation, you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41). Anytime outside a sale Control Lock: BLIND 45 [#/NS] [AT/TL] [#/NS]

OPERATION

CONDITION

OPERATION

CONDITION

OPERATION

CONDITION

8 digits fixed (00000000 to 99999999)

���������� �����

66 ����

+267 ,' ��������

���� �����70

1 digit (0 or 1) 1: Pulse dialing (Default) 2: Tone dialing

���������� �����

66 ����

',$/,1* �

���� �����70

Page 22: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.7 EFT Programming

4-14

4.7.7 Network List Output By this operation, list of network information stored in the EFT terminal (Data Tran) will be printed out from the printer provided for the ECR. In this list, functions programmed in the EFT terminal, allowance for the functions (ON/OFF status), and EFT terminal version will be printed. Before performing this operation, you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41) . Anytime outside a sale Control Lock: BLIND 46 [#/NS] [AT/TL] [#/NS] 4.7.8 Local Total Report Output By this operation, sales information stored in the EFT terminal will be printed out from the printer provided for the ECR. Before performing this operation, you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41) . Anytime outside a sale Control Lock: BLIND 47 [#/NS] [AT/TL] 4.7.9 Clear Current Batch By this operation, reported information for EFT will be cleared. Before performing this operation, you should make sure that the EFT terminal is connected and that the EFT setting had been done in 4.35 COM Port Setting (Submode 41) . Anytime outside a sale Control Lock: BLIND 48 [#/NS] [AT/TL]

OPERATION

CONDITION

���������� �����

66 ����

� ����������� ������� ����������� ������� ����������� ������� ����������� ������� ����������� ������� ����������� ������� ����������� ������� ����������� �������� ����������� ������

���� �����70

Amount, Count 2: AMEX 7: Diner’s Club or Carte Blanche 3: VISA 8: JCB 4: Master Card 9: Debit 5: Discover 99: Total for all card types 6: Private Label

OPERATION

CONDITION

OPERATION

CONDITION

���������� �����

66 ����

&+. 96� 1'2 ��� 9HU� ����21 21 21 2))

���� �����70

Functions programmedin the EFT terminal

Allowance for the functions (ON/OFF status)

EFT terminal Version

���������� �����

66 ����

()7 5(3257 &/($5

���� �����70

Page 23: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.8 Store Message and Commercial Message Programming (Submode 1)

4-15

4.8 Store Message and Commercial Message Programming (Submode 1) Store Message and Commercial Message to be printed as receipt header can be programmed here. Anytime outside a sale Control Lock: SET 01 [#/NS] |Line No.| [#/NS] Character Entries [AT/TL] [#/NS] NOTES: 1. For each line, up to 24 regular-sized characters or 12 double-sized characters can be

entered. Also a combination of both types can be entered. 2. If incorrect characters are programmed, depress the [C] key to clear all characters on a

line and then re-enter characters from the beginning, or end the line with the [AT/TL] key and reprogram the entire line. The new data will be active.

3. When all the lines have been programmed, do a check by issuing a receipt. Only the lines with errors requires to be re-programmed. Other lines will not be affected.

4. When blanks are entered for the whole one line, it causes one line space. Example) To program the following Store Message and Commercial Message (under the Store Message Print feature)

Max. 24 characters/line (See 4.2 Character Entry Method.)

2 digits (01 to 07)

(For sequentially programming lines, the Line Number specification can be skipped.)

Repeat for other lines.

Complete this line.

Complete this programming operation.

Line No. 1

Line No. 2

Line No. 3

Line No. 4

Line No. 5

Line No. 6

Line No. 7

1 3 4 3 P E A C H D R I V E

P H O N E : 8 7 - 6 4 3 7

O p e n 8 : 0 0 a m t o 7 : 0 0 p m

C l o s e d : e v e r y W e d n e s d a y

T E C S T O R E

OPERATION

CONDITION

Page 24: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.8 Store Message and Commercial Message Programming (Submode 1)

4-16

Key Operation: Control Lock: SET, Enter 01 and depress the [#/NS] key. 01 [#/NS] (Line No. 1) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [f] [f] [5] [4] (T) [f] [f] [4] [5] (E) [f] [f] [4] [3] (C) [2] [0] (Space) [2] [0] (Space) [f] [f] [5] [3] (S) [f] [f] [5] [4] (T) [f] [f] [4] [f] (O) [f] [f] [5] [2] (R) [f] [f] [4] [5] (E) [AT/TL] (to complete Line 1) 02 [#/NS] (Line No. 2) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [3] [1] (1) [3] [3] (3) [3] [4] (4) [3] [3] (3) [2] [0] (Space) [5] [0] (P) [4] [5] (E) [4] [1] (A) [4] [3] (C) [4] [8] (H) [2] [0] (Space) [4] [4] (D) [5] [2] (R) [4] [9] (I) [5] [6] (V) [4] [5] (E) [AT/TL] (to complete Line 2) 03 [#/NS] (Line No. 3) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [2] [0] (Space) [5] [0] (P) [4] [8] (H) [4] [f] (O) [4] [e] (N) [4] [5] (E) [3] [a] (:) [2] [0] (Space) [3] [8] (8) [3] [7] (7) [2] [d] (-) [3] [6] (6) [3] [4] (4) [3] [3] (3) [3] [7] (7) [AT/TL] (to complete Line 3) 05 [#/NS] (Line No. 5) [4] [f] (O) [7] [0] (p) [6] [5] (e) [6] [e] (n) [2] [0] (Space) [2] [0] (Space) [3] [8] (8) [3] [a] (:) [3] [0] (0) [3] [0] (0) [6] [1] (a) [6] [d] (m) [2] [0] (Space) [7] [4] (t) [6] [f] (o)

[2] [0] (Space) [3] [7] (7) [3] [a] (:) [3] [0] (0) [3] [0] (0) [7] [0] (p) [6] [d] (m) [AT/TL] (to complete Line 5) 06 [#/NS] (Line No. 6) [4] [3] (C) [6] [c] (l) [6] [f] (o) [7] [3] (s) [6] [5] (e) [6] [4] (d) [3] [a] (:) [2] [0] (Space) [6] [5] (e) [7] [6] (v) [6] [5] (e) [7] [2] (r) [7] [9] (y) [2] [0] (Space) [5] [7] (W) [6] [5] (e) [6] [4] (d) [6] [e] (n) [6] [5] (e) [7] [3] (s) [6] [4] (d) [6] [1] (a) [7] [9] (y) [AT/TL] (to complete Line 6) 07 [#/NS] (Line No. 7) [2] [0] (Spaces of

24 characters) [2] [0] [AT/TL] (to complete Line 7) [#/NS] (to complete this

submode)

���������� �����

35*35* ����

�����77(& 6725((& 6725(

��������� 3($&+ '5,9(

�����3+21(� �������

�����2SHQ ����DP WR ����SP�����&ORVHG� HYHU\ :HGQHVGD\�����

���� �����70

Page 25: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.9 Cashier Code and Name Programming (Submode 2)

4-17

4.9 Cashier Code and Name Programming (Submode 2) Anytime outside a sale Control Lock: SET 02 [#/NS] |Cashier Code| [#/NS] Character entry [AT/TL] |Pass Code| [AT/TL] |HALO||LALO|* [AT/TL] |Commission Rate| [AT/TL] |Commission Amount| [AT/TL] |Security Code 1| |Security Code 2| [AT/TL] |Cashier Status| [AT/TL] [#/NS]

OPERATION

CONDITION

Max. 18 characters (See NOTE 2 on the next page.)

2 digits (01 to 40)

Repeat for other cashiers.

01: Cashier Name

3 digits (000 to 999) (See NOTE 3 on the next page.)

02: Cashier Pass Code

1 digit 1 digit

03: High Amount Limit/Low Amount Limit

0.00 to 99.99% (Use the [.] key when a decimal point is contained in the rate.)

04: Commission Rate

1 digit (0 fixed) 0: Commission Amount = (Net Sale without Tax) x (Commission Rate)

05: Calculating the Commission Amount

2 digits (Enter the codes in numeric values.) (Refer to Cashier Security Code Table**.)

06: Cashier prohibited item

1 digit (0 to 2) 0: Cashier for sale entries 1: Supervisor (See NOTE 4 on the next page.) 2: Cashier for training entries (See NOTE 5 on the next page.)

07: Cashier Status

To complete this programming operation.

Page 26: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.9 Cashier Code and Name Programming (Submode 2)

4-18

*HALO/LALO (This setting will be effective as amount limit at the payment, Received-on-Account, or Paid-Out.)

HALO (High Amount to be Locked Out) LALO (Low Amount to be Locked Out) 0: No limit 0: No limit 1: 1 digit (0 to 9) 1: 1 digit (1 to 9999999) 2: 2 digits (0 to 99) 2: 2 digits (10 to 9999999) 3: 3 digits (0 to 999) 3: 3 digits (100 to 9999999) 4: 4 digits (0 to 9999) 4: 4 digits (1000 to 9999999) 5: 5 digits (0 to 99999) 5: 5 digits (10000 to 9999999) 6: 6 digits (0 to 999999) 6: 6 digits (100000 to 9999999) 7: 7 digits (0 to 9999999) 7: 7 digits (1000000 to 9999999) **Cashier Security Code Table Security Code Table 1

0 1 2 3 4 5 6 7 Prohibition of Returned Merchandise and Bottle Return Operation

O O O O

Prohibition of Amount Discount, Amount Charge, Percent Discount and Percent Charge Operation O O O O

Prohibition of Negative PLU/Department Entry and Correct Operation (NOTE 6)

O O O O

Security Code Table 2

0 1 2 3 4 5 6 7 Prohibition of Tax Exemption, Vendor Coupon and Store Coupon Operation O O O O

Prohibition of Finalizing Operation when the total is less than 0.

O O O O

Prohibition of Paid-Out Operation O O O O

NOTES: 1. In each item setting, depressing the [AT/TL] key without data entry skips to the next

item setting. 2. Entering 2 digits of numeric code provides an alphanumeric character of Cashier Name.

Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a Cashier Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Cashier name, up to 18 regular-sized or 9 double-sized characters can be entered. Also a combination of both types can be entered.

3. If you enter “000”, this ECR is released from the Pass Code system. 4. When “1: Supervisor” is set as cashier status, the cashier can always interrupt other

cashiers. When a cashier requires to perform prohibited operations, the cashier programmed as Supervisor can release the prohibition by SIGN-IN, resulting to perform any operations. (Before V2) When interrupting another cashier’s operation, the Supervisor can perform only one operation just after releasing the prohibition. After that, the prohibitive condition is restored. (V2 and after)

5. After selecting Cashier for Training Entry, a cashier can operate the same transaction entries as those in the REG mode. The data in the training mode is not processed, therefore, not affect any actual sales data in business. “TRAINING” as header will be printed on the receipt.

6. After “Prohibition of Correct Operation” is set, Void and All Void operations will be invalid.

Page 27: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.9 Cashier Code and Name Programming (Submode 2)

4-19

Example) To program the following cashier data Cashier Code: 01 Cashier Name: Jones Pass Code: 111 HALO/LALO: No limit/No limit Commission Rate: 0.5% Commission Amount: (Net sale without Tax) x (Commission Rate) Cashier prohibited item: Paid-Out operation Cashier Status: Cashier for sale entries Key Operation: Control Lock: SET, Enter 02 and depress the [#/NS] key. [0] [1] [#/NS] (Cashier Code) [4] [a] (J) [4] [f] (O) [4] [e] (N) [4] [5] (E) [5] [3] (S) [AT/TL] [1] [1] [1] [AT/TL] (02: Cashier Pass Code) [0] [0] [AT/TL] (03: HALO/LALO) [0] [.] [5] [AT/TL] (04: Commission Rate) [0] [AT/TL] (05: Commission Amount) [0] [4] [AT/TL] (06: Cashier prohibited item) [0] [AT/TL] (07: Cashier Status) [#/NS] (Complete this submode.)

(01: Cashier Name) ���������� �����

35*35* ����

�����-21(6

��� ������ ����� ������� ���� ����� �

���� �����70

Page 28: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Feb. 28, 2003)

4.10 Department Table Programming (Submode 3)

4-20

4.10 Department Table Programming (Submode 3) To change the positive/negative, Hash Department and Age Limit statuses: After Department Reset To change any other programmed data or to newly program departments: Anytime outside a sale Control Lock: SET 03 [#/NS] |Department Code| [#/NS] Character entry [AT/TL] |Preset Price| [AT/TL] |Tax Status Code| [AT/TL] |Group Number| [AT/TL] |HALO||LALO| [AT/TL] |Status 1 Code| |Age Limit Code| [AT/TL] |Status 2 Code| |Scale Status Code| [AT/TL] [#/NS]

OPERATION

CONDITION

Max. 18 characters (See NOTE 2 on the next page.)

2 digits (01 to 99)

Repeat for other departments.

01: Department Name

Max. 8 digits (0 to 99999999) (See NOTE 8 on the next page.)

02: Preset Price

Max. 5 digits (See NOTE 3 on the next page.)

03: Tax Status

2 digits (01 to 09)

04: Department Group Number

1 digit 1 digit (See NOTE 4 on the next page.)

05: High Amount Limit digit/Low Amount Limit digit

1 digit (See NOTE 5 on the next page.)

06: Status 1 Code/Age Limit Code

1 digit 1 digit (See NOTE 7 on the next page.)

07: Status 2 Code/Scale Status Code

To complete this programming operation.

1 digit (0 to 4) (See NOTE 6 on the next page.) 0: None (Default) 3: Age Limit Code 3 1: Age Limit Code 1 4: Age Limit Code 4 2: Age Limit Code 2

Page 29: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.10 Department Table Programming (Submode 3)

4-21

NOTES: 1. In each item setting, depressing the [AT/TL] key without data entry skips to the next item setting.

2. Entering 2 digits of numeric code provides an alphanumeric character of Department Name. Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a Department Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Department name, up to 18 regular-sized or 9 double-sized characters can be entered. Also a combination of both types can be entered.

3. Enter a maximum of 5 digits by combining 0 to 5. 0: Non-taxable 1: Tax 1 (Tax 1 taxable) 2: Tax 2 (Tax 2 taxable) 3: Tax 3 (Tax 3 taxable) 4: Tax 4 (Tax 4 taxable) 5: Food stamp

4. HALO/LALO HALO (High Amount to be Locked Out) LALO (Low Amount to be Locked Out) 0: No limit 0: No limit 1: 1 digit (0 to 9) 1: 1 digit (1 to 9999999) 2: 2 digits (0 to 99) 2: 2 digits (10 to 9999999) 3: 3 digits (0 to 999) 3: 3 digits (100 to 9999999) 4: 4 digits (0 to 9999) 4: 4 digits (1000 to 9999999) 5: 5 digits (0 to 99999) 5: 5 digits (10000 to 9999999) 6: 6 digits (0 to 999999) 6: 6 digits (100000 to 9999999) 7: 7 digits (0 to 9999999) 7: 7 digits (1000000 to 9999999)

5. Status 1 Code Table (Default: 0) Item Code 0 1 2 3 4 5 6 7

Single Item O O O O

Negative Department O O O O

Hash Department O O O O

6. Age Limit Code can be programmed in 4.44 Age Limit Setting (Submode 55) .

7. Status 2 Code Table (Default: 0) Item Code 0 1 2 3 4 5 6 7

Store Coupon O O O O

Gasoline Status O O O O

Split Package Pricing is available. (V2 and after) O

Scale Status Code Table (Default: 0) Item Code 0 1 2 3 4 5 6 7

Scale Status O O O O

Tare 2 (Manual Tare) Entry Compulsion O O

Food Stamp Symbol is printed. (NOTE 9) O O O O

8. Be sure to enter the amount less than cent when programming the preset price of gasoline only. (Up to $999.999 can be entered.)

9. This status is effective only when Canadian Tax System is set.

Enter a maximum of 5 digits by combining 0 to 5.

Page 30: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.10 Department Table Programming (Submode 3)

4-22

Example) To program the following department data Department Code: 01 Department Name: VEGETABLE Preset Price: Open Tax Status: Tax 1 taxable and Foot Stamp Department Group No.: 01 HALO/LALO: No limit/No limit Status 1 Code/Age Limit Code: None/None Status 2 Code/Scale Status Code: None/None Key Operation: Control Lock: SET, Enter 03 and depress the [#/NS] key. [0] [1] [#/NS] (Department Code) [5] [6] (V) [4] [5] (E) [4] [7] (G) [4] [5] (E) [5] [4] (T) [4] [1] (A) [4] [2] (B) [4] [c] (L) [4] [5] (E) [AT/TL] [AT/TL] (02: Preset Price (open)) [1] [5] [AT/TL] (03: Tax Status) [0] [1] [AT/TL] (04: Department Group Number) [0] [0] [AT/TL] (05: HALO/LALO) [0] [0] [AT/TL] (06: Status 1 Code/Age Limit Code) [0] [0] [AT/TL] (07: Status 2 Code/Scale Status Code) [#/NS] (Complete this submode.)

(01: Department Name)

���������� �����

35*35* ����

�����9(*(7$%/(

��� ����� ����� ����� ����� ��

���� �����70

Page 31: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.11 PLU Table Programming (Submode 4)

4-23

4.11 PLU Table Programming (Submode 4) To program new PLUs or to change any programmed contents of PLUs except the

following case: Anytime outside a sale To change the linked Department of a PLU with sales data not zero: After PLU Reset Control Lock: SET 04 [#/NS] |PLU Code| [#/NS]

|Source Code or In-Store Code| [X/TIME] Barcode Scanning Character entry [AT/TL] |Preset Price| or |Unit Price of Whole Package| [AT/TL] |2nd Preset Price| or |Unit Price of Indiv. Split Package| [AT/TL] |3rd Preset Price| or |Whole Package Quantity| [AT/TL] |Tax Status| [AT/TL] |PLU Group Number| [AT/TL] |Department Code| [AT/TL] |Status Code| |Scale Status Code| [AT/TL] |HALO| |LALO| [AT/TL] |Link PLU No. 1| or |M & M Group No.| [AT/TL]

OPERATION

CONDITION

Max. 14 digits (Free code) (See NOTE 2 on the next page.)

Repeat for other PLUs.

Max. 18 characters (See NOTE 4 on the next page.)

01: PLU Name

Max. 8 digits (0 to 99999999)

02: Preset Price/Unit Price of Whole Package for HI-CONE PLU

03: 2nd Preset Price/Unit Price of Indiv. Split Package

04: 3rd Preset Price/Whole Package Quantity for HI-CONE PLU

Max. 5 digits (See NOTE 5 on the next page.)

05: Tax Status

2 digits (01 to 99)

06: PLU Group Number

2 digits (01 to 99) (See NOTE 6 on the next page.)

07: Link Department

08: Status Code/Scale Status Code

1 digit 1 digit (See NOTE 8 on the next page.)

09: High Amount Limit digit/Low Amount Limit digit

2 digits (01 to 50) (See NOTE 9 on the next page.)

10: Link PLU No. 1/M & M Group Number

(See NOTE 3 on the next page.)

Max. 8 digits (0 to 99999999)

Max. 8 digits (0 to 99999999)

Max. 8 digits (0 to 99999999)

1 digit 1 digit (See NOTE 7 on the next page.)

2 digits (01 to 99) (See NOTE 10 on the next page.)

*1

Max. 8 digits (0 to 99999999)

Max. 8 digits (0 to 99999999)

*1

*1

*1,*2

*2

A

(Continued on the next page) *1: This setting is exclusive to the PLU allocated HI-CONE PLU in the Status Code setting.

*2: This setting is exclusive to the PLU allocated M & M Table in the Status Code setting.

Page 32: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.11 PLU Table Programming (Submode 4)

4-24

|Link PLU No. 2| [AT/TL] |Link PLU No. 3| [AT/TL] |PLU Stock Quantity| [AT/TL] |Tare Table No.| [AT/TL] |Unit Weight Code| [AT/TL] [#/NS] NOTES: 1. In each item setting, depressing the [AT/TL] key without data entry skips to the next

item setting. 2. Up to 24,000 PLUs are programmable. (The Number of PLU varies depending on the

capacity and allocation of the RAM.) 3. Before using the In-store Bar Code, you should perform the setting in 4.36 In-Store

Marking Bar Code Programming (Submode 42) . In case the following conditions, pressing the [X/TIME] key adds the Check Digit value to the code, resulting that the PLU No. will be generated automatically.

• In case 7-digit-or-less values are entered. • In case 11-digit or 12 digit values are entered.

4. Entering 2 digits of numeric code provides an alphanumeric character of PLU Name. Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a PLU Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the PLU name, up to 18 regular-sized or 9 double-sized characters can be entered. Also a combination of both types can be entered.

5. Enter a maximum of 5 digits by combining 0 to 5. 0: Non-taxable 1: Tax 1 (Tax 1 taxable) 2: Tax 2 (Tax 2 taxable) 3: Tax 3 (Tax 3 taxable) 4: Tax 4 (Tax 4 taxable) 5: Food stamp

6. Enter 2-digit of Department Code to which the PLU is linked. When the PLU is newly programmed, this entry is compulsory. (This entry can be skipped, however, an error occurs when this programming is completed. Therefore, this entry is compulsory.) When linked to HASH Department, a PLU will be HASH PLU. When a linked department is processed by single item, a PLU is also processed in the same way.

2 digits (01 to 50) (See NOTE 9 on the next page.)

11: Link PLU No. 2

2 digits (01 to 50) (See NOTE 9 on the next page.)

12: Link PLU No. 3

0.001 to 9999.999 (Use the [.] key when a decimal point is contained in the rate.)

13: PLU Stock Quantity

(To complete this programming operation.)

(Continued from the previous page) A

1 digit (0 to 9) 0: No Tare Table (See NOTE11.)

14: Tare Table Number

0 to 11 (0: Following the unit weight in the system) (See NOTE12.)

15: Unit Weight Code

Enter a maximum of 5 digits by combining 0 to 5.

Page 33: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.11 PLU Table Programming (Submode 4)

4-25

(Revision Date: Feb. 28, 2003)

7. Status Code and Scale Status Code are as the tables below show. Status Code Table (Default: 0) Item Code 0 1 2 3 4 5 6 7

Negative O O O O

HI-CONE Status O O O O

M & M Table O O

By HI-CONE Status setting, a PLU will be programmed for commodities in a package.

Scale Status Code Table (Default: 0) Item Code 0 1 2 3 4 5 6 7

Scale Status O O O O

Tare 2 (Manual Tare) Entry Compulsion O O

Food Stamp Symbol is printed. (NOTE 13) O O O O

8. HALO digit/LALO digit HALO (High Amount to be Locked Out) LALO (Low Amount to be Locked Out) 0: No limit 0: No limit 1: 1 digit (0 to 9) 1: 1 digit (1 to 9999999) 2: 2 digits (0 to 99) 2: 2 digits (10 to 9999999) 3: 3 digits (0 to 999) 3: 3 digits (100 to 9999999) 4: 4 digits (0 to 9999) 4: 4 digits (1000 to 9999999) 5: 5 digits (0 to 99999) 5: 5 digits (10000 to 9999999) 6: 6 digits (0 to 999999) 6: 6 digits (100000 to 9999999) 7: 7 digits (0 to 9999999) 7: 7 digits (1000000 to 9999999)

9. “00” indicates that no Link PLU exists. This setting is applied to the PLUs without M & M Table setting. Up to 99 can be entered, however, the Numbers 51 to 99 indicate that no Link PLU exists.

10. M & M Group Item PLU PLU1 PLU2 PLU3

Whole Package Price 100 100 100

Whole Package Quantity 3 3 3

Unit Price of Individual Split Package 40 40 40

In case PLU1 to PLU3 are set in different M & M Groups respectively: 1 [SPLIT PRICE] 1 [PLU] --- 40 1 [SPLIT PRICE] 2 [PLU] --- 40 The amount total will be 120. 1 [SPLIT PRICE] 3 [PLU] --- 40

In case PLU1 to PLU3 are set in the same M & M Group: 1 [SPLIT PRICE] 1 [PLU] --- 40 1 [SPLIT PRICE] 2 [PLU] --- 40 1 [SPLIT PRICE] 3 [PLU] --- 20 11. The Tare Table can be programmed in 4.45 Tare Table Setting (Submode 56) .

The amount total (whole package price) will be 100 so that the unit price of individual split package of PLU3 is arranged automatically.

Page 34: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.11 PLU Table Programming (Submode 4)

4-26

12. Unit Weight Code Table General Unit Weight Code LB Unit Kg Unit

1 1 LB 1 Kg 2 2 LB 2 Kg 3 3 LB 3 Kg 4 4 LB 4 Kg 5 5 LB 5 Kg 6 6 LB 6 Kg 7 7 LB 7 Kg 8 8 LB 8 Kg 9 9 LB 9 Kg

10 1/2 LB 100 g 11 1/4 LB ---

13. This status is effective only when Canadian Tax System is set. Example) To program the following PLU data PLU Code: 01000000010101 PLU Name: Tomato Preset Price: 1.00 2nd Preset Price: 1.20 3rd Preset Price: 1.40 Tax Status: Tax 1 taxable and Food Stamp PLU Group No.: 01 Linked Dept. Code: 01 Status Code/Scale Status Code: Positive/None HALO/LALO: No limit/No limit Link PLU No. 1: None Link PLU No. 2: None Link PLU No. 3: None Stock Quantity: 100.00 Tare Table No.: None Unit Weight Code: Unit Weight in the system Key Operation: Control Lock: SET, Enter 04 and depress the [#/NS] key. 01000000010101 [#/NS] (PLU Code) [5] [4] (T) [6] [f] (o) [6] [d] (m) [6] [1] (a) [7] [4] (t) [6] [f] (o) [AT/TL] [1] [0] [0] [AT/TL] (02: Preset Price) [1] [2] [0] [AT/TL] (03: 2nd Preset Price) [1] [4] [0] [AT/TL] (04: 3rd Preset Price) [1] [5] [AT/TL] (05: Tax Status) [0] [1] [AT/TL] (06: PLU Group Number) [0] [1] [AT/TL] (07: Linked Dept. Code) [0] [0] [AT/TL] (08: Status Code/Scale Status Code) [0] [0] [AT/TL] (09: HALO/LALO) [0] [0] [AT/TL] (10: Link PLU No. 1) [0] [0] [AT/TL] (11: Link PLU No. 2) [0] [0] [AT/TL] (12: Link PLU No. 3) [1] [0] [0] [AT/TL] (13: Stock Quantity) [0] [AT/TL] (14: Tare Table Number) [0] [AT/TL] (15:Unit Weight Code) [#/NS] (Complete this submode.)

(01: PLU Name)

���������� �����

35*35* ����

�����������������

7RPDWR��� ������� ������� ������� ����� ����� ����� ����� ����� ����� ����� ����� ���������� ���� ��

���� �����70

Page 35: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.12 Time Setting or Adjustment (Submode 5)

4-27

Deletion After PLU reset Control Lock: SET 04 [#/NS] [VOID] |PLU Code| [#/NS] [#/NS] Max. 14digits

|Source Code or In-Store Code| [X/TIME] Barcode Scanning Example) To delete PLU No. 01000000090101 (Coke Small-A) that was programmed. Key Operation: Control Lock: SET, Enter 04 and depress the [#/NS] key. [VOID] 01000000090101 [#/NS] (PLU Code) [#/NS]

4.12 Time Setting or Adjustment (Submode 5) Anytime outside a sale Control Lock: SET 05 [#/NS] |Hour| |Minute| [AT/TL] [#/NS] (00 to 23) (00 to 59)

NOTE: If an hour value of more than 23 or a minute value of more than 59 is entered, an error occurs. Example) To set time “1:15 p.m. (13:15)”. Key Operation: Control Lock: SET, Enter 05 and depress the [#/NS] key. [1] [3] [1] [5] [AT/TL] [#/NS]

OPERATION

CONDITION

OPERATION

CONDITION

���������� �����

35*35* ����

����� ����

���� �����70

Repeat for other PLUs.

���������� �����

35*35* ����

∗∗∗∗∗∗ 3/8 '(/(7( ∗∗∗∗∗∗��������������

���&RNH 6PDOO�$

���� �����70

Page 36: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.13 Date Setting or Adjustment (Submode 6)

4-28

4.13 Date Setting or Adjustment (Submode 6) Anytime outside a sale Control Lock: SET 06 [#/NS] |Day| |Month| |Year| [AT/TL] [#/NS] (01 to 31) (01 to 12) (00 to 99)

NOTE: The date entry order may be Month-Day-Year or Year-Month-Day instead of Day-Month-Year

if so selected in 4.40 Date Format Setting . After RAM clear, ”Day-Month-Year” is set as a default.

Example) To set date “January 24, 2002”. Key Operation: Control Lock: SET, Enter 06 and depress the [#/NS] key. [2] [4] [0] [1] [0] [2] [AT/TL] [#/NS]

4.14 Media Tender Key Setting (Submode 8) Media Tender Keys and the High Amount Limit/Low Amount Limit in finalizing transactions by tendering through each media key which is functioned by SFKC programming can be set in this submode. Anytime outside a sale Control Lock: SET 08 [#/NS] |Media Tender key No.| [#/NS] Character entry [AT/TL] |HALO| |LALO| [AT/TL] |Status Code 1| |Status Code 2| [AT/TL] [#/NS]

OPERATION

CONDITION

OPERATION

CONDITION

2 digits (01 to 09) (01: CASH media is fixed., 02: CHECK media is fixed.)

Repeat for other Media Tender Keys.

To complete this programming operation.

Max. 12 characters (See NOTE 1 on the next page.)

1 digit 1 digit (See NOTE 2 on the next page.)

1 digit (0 to 7) 1 digit (0 to 7) (See NOTE 3 on the next page.)

���������� �����

35*35* ����

����� ������

���� �����70

Page 37: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.14 Media Tender Key Setting (Submode 8)

4-29

NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Media Tender Key Name. Therefore, odd number of numeric digit entry will cause an error. When less than 24 digits of numeric data are entered, this ECR uses space code entry. If a Media Tender Key Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Media Tender Key name, up to 12 regular-sized or 6 double-sized characters can be entered. Also a combination of both types can be entered.

2. HALO digit/LALO digit HALO (High Amount to be Locked Out) LALO (Low Amount to be Locked Out) 0: No limit 0: No limit 1: 1 digit (0 to 9) 1: 1 digit (1 to 9999999) 2: 2 digits (0 to 99) 2: 2 digits (10 to 9999999) 3: 3 digits (0 to 999) 3: 3 digits (100 to 9999999) 4: 4 digits (0 to 9999) 4: 4 digits (1000 to 9999999) 5: 5 digits (0 to 99999) 5: 5 digits (10000 to 9999999) 6: 6 digits (0 to 999999) 6: 6 digits (100000 to 9999999) 7: 7 digits (0 to 9999999) 7: 7 digits (1000000 to 9999999)

3. Prohibited/restricted items are programmed by a combination of Status Code 1 and Status Code 2.

Status Code 1 Table : Default setting after RAM clear 0 1 2 3 4 5 6 7 Over-tendering (tendering an amount larger than the sale total) is prohibited. O O O O

Short-tendering (tendering an amount less than the sale total) is prohibited. O O O O

Opening the drawer is prohibited. O O O O

Status Code 2 Table 0 1 2 3 4 5 6 7 Entering the Non-add # is required. O O O O Depressing the [ST] key before finalizing by the tender key is required. O O O O

Entering the price at tendering is required. O O O O Example) To program “Media Tender Key No.02” Key Name: CHECK HALO/LALO: No limit/No limit Prohibited/restricted items: Over-tendering is prohibited. Entering the price at tendering is required. Key Operation: Control Lock: SET, Enter 08 and depress the [#/NS] key. [0] [2] [[#/NS] (Media Tender Key No.) [4] [3] (C) [4] [8] (H) [4] [5] (E) [4] [3] (C) [4] [b] (K) [AT/TL] [0] [0] [AT/TL] (HALO/LALO) [1] [4] [AT/TL] (Status Codes 1 and 2) [#/NS]

(Key Name)

���������� �����

35*35* ����

����� &+(&.��� ����� ����� ��

���� �����70

Page 38: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.15 Financial Report Item Name Programming (Submode 9)

4-30

4.15 Financial Report Item Name Programming (Submode 9) Item Names printed on Financial Report are programmed here. Many of them are also printed on sales receipts. Other Line Item Names will be programmed in 4.16 Print Line Item Name Programming (Submode 10) . After Financial Reset Control Lock: SET 09 [#/NS] |Item Code|[#/NS] Character entry [AT/TL] [#/NS] NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Financial

Report Item Name. Therefore, odd number of numeric digit entry will cause an error. When less than 24 digits of numeric data are entered, this ECR uses space code entry. If a Financial Report Item Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Financial Report Item name, up to 12 regular-sized or 6 double-sized characters can be entered. Also a combination of both types can be entered.

2. As shown in the table on the next pages, the Standard program data are pre-programmed (which is auto-set after a RAM Clear). Therefore, program only the items that need to be changed.

Example) To program “NET GT” instead of “NET GT” for Item Code 02 (NET GT) all in double-sized characters. Key Operation: Control Lock: SET, Enter 09 and depress the [#/NS] key. [0] [2] [#/NS] (Item Code) [f] [f] [4] [e] (N ) [f] [f] [4] [5] (E ) [f] [f] [5] [4] (T ) [f] [f] [2] [0] (Space) [f] [f] [4] [7] (G ) [f] [f] [5] [4] (T ) [AT/TL] [#/NS] (To complete this submode)

OPERATION

CONDITION

(See the table on the next pages.)

Max. 12 characters (See NOTE 1 below.)

the end of each item name. (Any unprogrammed parts will be filled with blanks.)

Repeat for other items.

(Item Name)

���������� �����

35*35* ����

����� 1(7 *71(7 *7

���� �����70

Page 39: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.15 Financial Report Item Name Programming (Submode 9)

4-31

Financial Report Item Name Table

Item Code

Item Name Standard Program

01 Ground Total G T 02 NET GT N E T G T 03 Gross Sale G S 04 %+ on Subtotal % + 05 Amount Charge on Subtotal A D D O N 06 Net Sale without Tax N S w / o T a x 07 Add on Tax 1 T A X 1 08 Add on Tax 2 T A X 2 09 Add on Tax 3 T A X 3 10 Add on Tax 4 T A X 4 11 Net Sale with Tax N S w / T a x 12 Positive Hash Department H A S H D P T 13 Negative Hash Department - H A S H D P T 14 %- on Subtotal % - 15 Amount Discount on Subtotal D I S C 16 Vender Coupon V . C P N 17 Bottle Return B T R 18 Negative Department - D P T 19 Special Round S P . R O U N D 20 All Media Sales M E D I A T L 21 Reserved 22 Food Stamp Sales F S T L 23 Received-on Account R / A 24 Paid-Out P O 25 Loan L O A N 26 Pick Up P I C K U P 27 Cash-in-Drawer C A S H I D 28 Media 2-in Drawer (Check) C H E C K I D 29 Media 3-in Drawer (Chg) C H A R G E I D 30 Media 4-in Drawer (CPN) C O U P O N I D 31 Media 5-in Drawer (Credit 1) C R E D I T - 1 I D 32 Media 6-in Drawer (Credit 2) C R E D I T - 2 I D 33 Media 7-in Drawer (Credit 3) C R E D I T - 3 I D 34 Media 8-in Drawer (Credit 4) C R E D I T - 4 I D 35 Media 9-in Drawer (Credit 5) C R E D I T - 5 I D 36 Food Stamp-in-Drawer F S I D 37 Food Stamp Change F S C G 38 Cash-in-Drawer Difference C A S H D I F 39 Media 2-in-Drawer (Check) Difference C H E C K D I F 40 Media 3-in Drawer (Chg) Difference C H A R G E D I F 41 Media 4-in Drawer (CPN) Difference C O U P O N D I F 42 Media 5-in Drawer (Credit 1) Difference C R E D I T - 1 D I F 43 Media 6-in Drawer (Credit 2) Difference C R E D I T - 2 D I F 44 Media 7-in Drawer (Credit 3) Difference C R E D I T - 3 D I F 45 Media 8-in Drawer (Credit 4) Difference C R E D I T - 4 D I F 46 Media 9-in Drawer (Credit 5) Difference C R E D I T - 5 D I F

Page 40: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.15 Financial Report Item Name Programming (Submode 9)

4-32

Financial Report Item Name Table (Continued)

Item Code

Item Name Standard Program

47 Void/Item Correct V O I D / C O R R 48 All Void Total A L L V O I D 49 Store Coupon S . C P N 50 Returned Merchandise R T N 51 %+ on Line Items I T E M % + 52 Amount Charge on Line Items I T E M A D D O N 53 %- on Line Items I T E M % - 54 Amount Discount on Line Items I T E M D I S C 55 Negative Tax - T A X 56 Negative Mode Total R E G - 57 Taxable Total 1 T X B L T L 1 58 Taxable Total 2 T X B L T L 2 59 Taxable Total 3 T X B L T L 3 60 Taxable Total 4 T X B L T L 4 61 Tax-Exempted Counter E X C U S 62 Tax 1 Exempted Sales T A X E X 1 63 Tax 2 Exempted Sales T A X E X 2 64 Tax 3 Exempted Sales T A X E X 3 65 Tax 4 Exempted Sales T A X E X 4 66 Reserved 67 [C] Key Counter C L E A R C T R 68 No-Sale Counter N O - S A L E 69 Validation Counter V A L I C T R 70 Power ON/OFF Counter P O W E R O F F / O N 71 Initial Counter # I N I C I A L 72 Transaction Address of Department (BLIND ) D E P T - T R N 73 Setting Address of Department (BLIND ) D E P T - P R G 74 Reserved 75 Setting Address of Cashier (BLIND ) C A S H I E R - P R G 76 Sale Address of Department (BLIND ) D E P T - S A L E 77 Reserved 78 Sale Address by Cashier (BLIND ) C A S H I E R - S A L E 79 Base Memory End Address (BLIND ) E N D - B A S E 80 Start Address of PLU No. (BLIND ) P L U - S T A R T 81 End Address of PLU No. (BLIND ) P L U - E N D 82 Reserved 83 Reserved 84 Reserved 85 Reserved 86 PLU Type Setting Code (BLIND ) P L U - T Y P E 87 Number of Department Setting (BLIND ) D E P T 88 Number of PLU Setting (BLIND ) P L U 89 Number of Cashier Setting (BLIND ) C A S H I E R 90 Reserved 91 Reserved 92 Reserved

Page 41: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.16 Print Line Item Name Programming (Submode 10)

4-33

Financial Report Item Name Table (Continued)

Item Code

Total/Counter Name Standard Program

93 NEG-GT N E G - G T 94 Commission C O M M I S S I O N 95 MISC VOID M I S C V O I D 96 Reserved 97 Reserved 98 Reserved 99 Reserved

4.16 Print Line Item Name Programming (Submode 10) Print Line Item Names not listed in 4.15 Financial Report Item Name Programming (Submode 9) can be programmed here. Anytime outside a sale Control Lock: SET 10 [#/NS] |Item Code|[#/NS] Character entry [AT/TL] [#/NS] NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Print Line Item Name.

Therefore, odd number of numeric digit entry will cause an error. When less than 24 digits of numeric data are entered, this ECR uses space code entry. If a Print Line Item Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Print Line Item name, up to 12 regular-sized or 6 double-sized characters can be entered. Also a combination of both types can be entered.

2. As shown in the table on the next pages, the Standard program data are pre-programmed (which is auto-set after a RAM Clear). Therefore, program only the items that need to be changed.

3. The name in Standard Program for Item Code 7 Amount Mark is set with a blank after a RAM Clear. When the specific amount mark for domestic currency (such as $) is required on sales receipts, you must program the entire contents of Item Code 7.

4. The Cashier Symbol to be set in Item Code 8 (“CL” in Standard Program) will be used to print 2-digit Cashier ID Code on a validation slip. On receipts, the name of cashier programmed in the Cashier Code and Name Programming operation will be printed.

5. Even when partly altering the contents of Item Codes 7 through 11, you must program the entire contents.

Print Line Item Name Table

Item Code

Item Name/Application Standard Program

01 Subtotal in transactions S U B T L 02 Reserved 03 Sale Total each transactions T O T A L 04 Change due in transaction C H A N G E

OPERATION

CONDITION

(See the table on the next pages.)

Max. 12 characters (See NOTE 1 below.)

Indicates the end of each item name. (Any unprogrammed parts will be filled with blanks.)

Repeat for other items.

Page 42: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.16 Print Line Item Name Programming (Submode 10)

4-34

Print Line Item Name Table (Continued)

Item Code

Item Name/Application Standard Program

05 Reserved 06 Reserved 07 The following items must be set together. @ I T E M l b $

Unit Price Symbol (1 digit) Reserved (1 digit) Sale Item Count Symbol on Receipt (6 digits) Currency Symbol (1 digit) Weight Symbol (2 digits) Unit Price Symbol for Scale (1 digit)

08 The following items must be set together. # C L T M G S / Register No. Symbol (2 digits) Cashier/Clerk Symbol (2 digits) Time Symbol (2 digits) Gasoline Symbol (2 digits) Split Package Symbol (2 digits)

09 The following items must be set together. C U x Z 1 : Z 2 : Customer Count Symbol on Receipt (2 digits) Multiplication Symbol on Receipt (2 digits) Z1 Counter Symbol (3 digits) Z2 Counter Symbol (3 digits) Reserved (2 digits)

10 The following items must be set together. X Z P R G S G T X G T Z X mode Symbol (1 digit) Z mode Symbol (1 digit) PRG mode Symbol (3 digits) BLIND mode Symbol (1 digit) X2 mode Symbol (3 digits) Z2 mode Symbol (3 digits)

11 The following items must be set together. T T T T T F Tax Symbol (2 digits) Tax 1 Symbol (2 digits) Tax 2 Symbol (2 digits) Tax 3 Symbol (2 digits) Tax 4 Symbol (2 digits) Food Stamp Symbol (1 digit) Reserved (1 digit)

12 PLU Urgent Maintenance A D D P L U 13 Taxable Total T A X T L 14 Total Amount with Tax T X B L T L W T 15 Total Amount without Tax T X B L T L 16 Non-taxable N O T A X 17 Tax 1 Charge T A X 1 O N 18 Tax 2 Charge T A X 2 O N 19 Tax 3 Charge T A X 3 O N 20 Tax 4 Charge T A X 4 O N 21 Void V O I D 22 Item Correct C O R R

Page 43: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.16 Print Line Item Name Programming (Submode 10)

4-35

Print Line Item Name Table (Continued)

Item Code

Item Name/Application Standard Program

23 PLU Price Input P R I C E 24 Reserved 25 Reserved 26 Reserved 27 Reserved 28 Preset Price Read R E A D 29 Department Group Subtotal (V2 and after) S T 30 Reserved 31 Reserved 32 Reserved 33 Reserved 34 Reserved 35 Reserved 36 Food Stamp Paid F - S T A M P 37 PLU (Default Symbol) P L U 38 Department (Default Symbol) D E P T 39 Reserved 40 Reserved 41 Foreign Currency F C 42 Foreign Currency Rate Symbol ∗ 43 Programming Section S E C T I O N 44 Date & Time Setting D A T E T I M E 45 Cash (Default Symbol) C A S H 46 Check (Default Symbol) C H E C K 47 Charge (Default Symbol) C H A R G E 48 Coupon (Default Symbol) C O U P O N 49 Credit 1 (Default Symbol) C R E D I T - 1 50 Credit 2 (Default Symbol) C R E D I T - 2 51 Credit 3 (Default Symbol) C R E D I T - 3 52 Credit 4 (Default Symbol) C R E D I T - 4 53 Credit 5 (Default Symbol) C R E D I T - 5 54 Reserved 55 Reserved 56 Non-Taxable Total N O N T X B L 57 Taxable Net Total 1 N E T T L 1 58 Taxable Net Total 2 N E T T L 2 59 Taxable Net Total 3 N E T T L 3 60 Taxable Net Total 4 N E T T L 4 61 Check No. Symbol C H E C K N O . 62 Food Stamp Shift F S S H I F T 63 Reserved 64 Reserved 65 Decimal Point Symbol D E C I M A L P T 66 Rounding Symbol R O U N D I N G 67 EURO Rounding Symbol S P . R O U N D 68 Date Format D A T E F O R M A T

Page 44: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.17 Print Item on Reports Setting (Submode 11)

4-36

(Revision Date: Feb. 28, 2003)

Print Line Item Name Table (Continued)

Item Code

Item Name/Application Standard Program

69 Reserved 70 Auto Cutter A U T O C U T T E R 71 Stamp S T A M P 72 Reserved 73 Expiring Date of Merchant Receipt E X P D A T E 74 Amount C A R D 75 Authorized Code A P P # 76 Reference Number R E F # 77 Reserved 78 Birthday Check I D C H E C K 79 Scale Weight Manual Entry M A N W T 80 Scale Tare Weight T A R E / 81 Void Credit, Void Credit Return V O I D : 82 Credit & Debit Return R E F U N D : 83 Post Authorization P O S T A U T H :

Example) To program the weight symbol “Kg” in Item Code 7 (The amount mark has not been preset as the standard program data.)

Key Operation: Control Lock: SET, Enter 10 and depress the [#/NS] key. [0] [7] [#/NS] (Item Code) [4] [0] (@) [2] [0] (Space) [4] [9] (I) [5] [4] (T) [4] [5] (E) [4] [d] (M) [2] [0] (Space) [2] [0] (Space) [4] [b] (K) [6] [7] (g) [2] [4] ($) [AT/TL] [#/NS] (To complete this submode)

4.17 Print Item on Reports Setting (Submode 11) Anytime outside a sale Control Lock: SET 11 [#/NS] 01 [#/NS] |Print Item Code 1| |Print Item Code 2| [AT/TL] Fixed 1 digit (0 to 7) 1 digit (0 to 7) 02 [#/NS] |Print Item Code 3| |Print Item Code 4| [AT/TL] Fixed 1 digit (0 to 7) 1 digit (0 to 7) 03 [#/NS] |Print Item Code 5| |Print Item Code 6| [AT/TL] Fixed 1 digit (0 to 7) 1 digit (0 to 7)

[#/NS]

OPERATION

CONDITION

���������� �����

35*35* ����

����� # ,7(0 .J�

���� �����70

Page 45: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.17 Print Item on Reports Setting (Submode 11)

4-37

Print Item Code Table 1 : Default setting after RAM clear 0 1 2 3 4 5 6 7

GT (Grand Total) on Reports O O O O

Returned Merchandise on Reports O O O O

Void/Item Correct on Reports O O O O

Print Item Code Table 2 0 1 2 3 4 5 6 7

Read/Reset Count on Reports O O O O

Tax Rate on Reports O O O O

Reserved

Print Item Code Table 3 0 1 2 3 4 5 6 7

No-Sale Count on Reports O O O O

Reserved

[C] Key Counter on Reports O O O O

Print Item Code Table 4 0 1 2 3 4 5 6 7

Department and PLU Sales Ratio on Reports O O O O

Data “0” on the Department/PLU Reports (NOTE) O O O O Data “0” on Reports excepting the Department/PLU Reports (NOTE) O O O O

NOTE: Regardless of this option setting, zero-skip will be performed on both Read Report and Reset Report.

Print Item Code Table 5 0 1 2 3 4 5 6 7

Stock quantity is not printed on the PLU Report. O O O O Subtotal amount print for individual department group (V2 and after) (NOTE) O O O O

Reserved

NOTE: When this option has been set, subtotal for individual department group is printed on the department reports and on the DP and financial reports.

Print Item Code Table 6 0 1 2 3 4 5 6 7

Reserved

Reserved

Reserved

Example) To program the items below which will be printed on the report. GT (Grand Total) No-Sale Count [C] Key Counter Key Operation: Control Lock: SET, Enter 11 and depress the [#/NS] key. [0] [1] [#/NS] [6] [3] [AT/TL] [0] [2] [#/NS] [2] [0] [AT/TL] [0] [3] [#/NS] [0] [0] [AT/TL] [#/NS]

���������� �����

35*35* ����

����� ������� ������� ��

���� �����70

Page 46: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.18 Tax Table Programming (Submode 12)

4-38

4.18 Tax Table Programming (Submode 12) The rate of Tax, which is applicable for Department and PLU, can be programmed here. The Department and PLU have already been set in 4.10 Department Table Programming (Submode 3) and 4.11 PLU Table Programming (Submode 4) , respectively. After Financial Daily Reset Control Lock: SET 1) When “Canadian (General, Tax on tax, or Ontario)” is selected in 4.6 Tax System Programming ; 12 [#/NS] |Tax Code| [#/NS] |Rate| [AT/TL] [#/NS] NOTE: When “Canadian (Ontario)” is selected in 4.6 Tax System Programming , program Limit

Price in the following procedure. 12 [#/NS] 5 [#/NS] |Limit Price| [AT/TL] [#/NS] 2) When “US break” is selected in 4.6 Tax System Programming ;

TYPE 1: TAX 1 FULL BREAKS (COMBINATION OF NON-CYCLIC AND CYCLIC BREAKS) Enter 12, and depress the [#/NS] key. |Tax Code| [#/NS] 1 digit (1 to 4) 1: Tax 1, 2: Tax 2, 3: Tax 3, 4: Tax 4 |Max. amount non-taxable| [X/TIME] |Max. amount for 1¢ tax levied| [X/TIME] |Max. amount for 2¢ tax levied| [X/TIME] Repeat up to the “A” Break. |Max. amount for N¢ tax levied| [X/TIME] : “A” Break (Non-cyclic Break Limit) [ST] (to indicate the completion of Non-cyclic Breaks) |Max. amount for N + 1¢ tax levied| [X/TIME] : (beginning of Cyclic Breaks) |Max. amount for N + 2¢ tax levied| [X/TIME] Repeat up to the “B” Break (“B” Break – “A” Break + Multiple of $1.00; Up to $9.00) [#/NS] (to complete this tax table programming) NOTE: The break amount entry must be up to 4 digits (1 to 9999 resulting in $0.01 to $99.99)

OPERATION

CONDITION

Fixed Max. 8 digits (0 to 99999999)

1: Tax 1 2: Tax 2 3: Tax 3 4: Tax 4

0.00 to 99.99 (%): (Use the [.] key when a decimal point is contained in the rate.)

Repeat for other Tax rate.

Page 47: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.18 Tax Table Programming (Submode 12)

4-39

TYPE 2: TAX 1 COMBINATION OF NON-CYCLIC BREAKS AND % RATE Enter 12, and depress the [#/NS] key. |Tax Code| [#/NS] 1 digit (1 to 4) 1: Tax 1, 2: Tax 2, 3: Tax 3, 4: Tax 4 First set all the breaks up to the “A” Break entry, and then depress the [ST] key as shown in

TYPE 1. |Tax Rate applied when exceeding the “A” Break amount| [AT/TL] (0.00% to 99.999%; Use the [.] key when a decimal point is contained.

Examples; To set 5%, enter 5. To set 5.26%, enter 5.26. The fraction of the amount resulting from this % rate calculation will be rounded off.)

[#/NS] (to complete this tax programming) TYPE 3: TAX 1 % RATE ONLY 12 [#/NS] |Tax Code| [#/NS] 0 [X/TIME] [ST] |Tax Rate| [AT/TL] [#/NS] NOTES: 1. For Tax 2, Tax 3, and Tax 4 Table Programming, follow the same procedure in TYPE

1, 2, and 3 as shown the above. 2. If multiple tax tables are programmed, the Tax 1 table must be set first, and then Tax

2, Tax 3, and Tax 4. The Tax 1 table setting will automatically reset all of the old Tax 1, 2, 3, and 4 tables if they have been programmed.

3. Do not depress the [ST] key over twice in one tax table programming. 4. Up to 99 breaks can be entered for Tax 1 to Tax 4 tables together.

Example 1) TAX 1 FULL BREAKS

Tax Table Amount Range Tax Levied $0.00 to $0.10 0¢ $0.11 to $0.22 1¢ $0.23 to $0.39 2¢ $0.40 to $0.56 3¢ $0.57 to $0.73 4¢ $0.74 to $0.90 5¢ $0.91 to $1.08 6¢

---- “A” Break $1.09 to $1.24 7¢ $1.25 to $1.41 8¢ $1.42 to $1.58 9¢ $1.59 to $1.74 10¢ $1.75 to $1.92 11¢ $1.93 to $2.08 12¢

---- “B” Break

Key Operation Control Lock: SET, Enter 12 and depress the [#/NS] key. 1 [#/NS] 10 [X/TIME] 22 [X/TIME] 39 [X/TIME] 56 [X/TIME] 73 [X/TIME] 90 [X/TIME] 108 [X/TIME] [ST] 124 [X/TIME] 141 [X/TIME] 158 [X/TIME] 174 [X/TIME] 192 [X/TIME] 208 [X/TIME] [#/NS]

(The description for the Tax Rate in TYPE 2 is also applied to this case.)

���������� �����

35*35* ����

����� ����� ����� ����� ����� ����� ����� ���

67��� ������ ������ ������ ������ ������ ���

���� �����70

1 digit (1 to 4) 1: Tax 1, 2: Tax 2, 3: Tax 3, 4: Tax 4

Page 48: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.18 VAT or Add-on Tax Rate Setting (Submode 12)

4-40

Example 2) TAX 2 COMBINATION OF NON-CYCLIC BREAKS AND % RATE Tax Table

Amount Range Tax Levied $0.00 to $0.09 0¢ $0.10 to $0.29 1¢ $0.30 to $0.59 2¢ $0.60 to $0.84 3¢ $0.85 to $1.12 4¢

---- “A” Break 5% is applied to any amount

exceeding the “A” Break.

Key Operation Control Lock: SET, Enter 12 and depress the [#/NS] key. 2 [#/NS] 9 [X/TIME] 29 [X/TIME] 59 [X/TIME] 84 [X/TIME] 112 [X/TIME] [ST] 5 [AT/TL] [#/NS]

Example 3) TAX 10% RATE ONLY

Tax Table 10% is applied to any sale

amount.

Key Operation Control Lock: SET, Enter 12, and depress the [#/NS] key. 3 [#/NS] 0 [X/TIME] [ST] 10 [AT/TL] [#/NS]

���������� �����

35*35* ����

����� ���� ����� ����� ����� ���

67����� ����

���� �����70

���������� �����

35*35* ����

����� �67

����� �����

���� �����70

Page 49: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.19 Department Group Name Programming (Submode 13)

4-41

4.19 Department Group Name Programming (Submode 13) The Name of Department Group can be programmed here, which Department has already been linked to a Group in 4.10 Department Table Programming (Submode 3) . Anytime outside a sale Control Lock: SET 13 [#/NS] |Group Code| [#/NS] Character entry [AT/TL] [#/NS] NOTE: Entering 2 digits of numeric code provides an alphanumeric character of Department Group

Name. Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a Department Group Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Department Group name, up to 18 regular-sized or 9 double-sized characters can be entered. Also a combination of both types can be entered.

Example) To program the following names to the respective Groups: Group 1 Group 2 Group 3 Key Operation: Control Lock: SET, Enter 13 and depress the [#/NS] key. [0] [1] [#/NS] (Group 1) [f] [f] [4] [4] (D ) [f] [f] [5] [0] (P ) [f] [f] [2] [0] (Space) [f] [f] [4] [7] (G ) [f] [f] [5] [0] (P ) [f] [f] [2] [3] (# ) [f] [f] [3] [0] (0 ) [f] [f] [3] [1] (1 ) [AT/TL] [0] [2] [#/NS] (Group 2) [f] [f] [4] [4] (D ) [f] [f] [5] [0] (P ) [f] [f] [2] [0] (Space) [f] [f] [4] [7] (G ) [f] [f] [5] [0] (P ) [f] [f] [2] [3] (# ) [f] [f] [3] [0] (0 ) [f] [f] [3] [2] (2 ) [AT/TL]

[0] [3] [#/NS] (Group 3) [f] [f] [4] [f] (O )

[f] [f] [5] [4] (T ) [f] [f] [4] [8] (H ) [f] [f] [4] [5] (E ) [f] [f] [5] [2] (R ) [AT/TL] [#/NS] (To complete this submode)

OPERATION

CONDITION

D P G P # 0 1

D P G P # 0 2

O T H E R

���������� �����

35*35* ����

�����'3 *3���'3 *3���

�����

'3 *3���'3 *3���

�����

27+(527+(5

���� �����70

2 digits (01 to 09) Max. 18 characters (See NOTE below.)

Repeat for other Groups. (Max. 9 groups)

Page 50: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-42

(Revision Date: Feb. 28, 2003)

4.20 Display Upper-Row Message Programming (Submode 17) Messages to be displayed on the upper row of the Operator Display can be programmed here. The messages will be displayed when certain items are entered. Anytime outside a sale Control Lock: SET 17 [#/NS] |Item Code| [#/NS] Character entry [AT/TL] [#/NS]

Item Code Item Name/Application Standard Program

01 Reserved 02 Signed-OFF or Signed OUT condition (in REG, MGR, or - mode) L O G 03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 RAM Clear R A M - C 08 Data Clear D A T A - C 09 Status Clear S T A T U S - C 10 Reserved 11 Reserved 12 Reserved 13 Hold H O L D 14 Reserved 15 Reserved 16 Check Endorsement request C H E C K R E Q 17 Tax System Setting (BLIND ) T A X B A L A N C 18 PLU Type Code (BLIND ) P L U T Y P E 19 Number of Department Setting (BLIND ) D E P A R T M E N T 20 Number of PLU Setting (BLIND ) P L U 21 Number of Cashier Setting (BLIND ) C A S H I E R 22 Reserved 23 Reserved 24 SFKC Setting (BLIND ) K E Y A S S I G N 25 Verification of Programmed Data (BLIND ) D U M P 26 Store Message & Commercial Message Programming (SET CODE) L O G O L I N E 27 Cashier Code & Name Programming (SET CODE) C A S H I E R 28 Department Table Programming (SET CODE) D E P A R T M E N T 29 PLU Table Programming (SET CODE) P L U 30 Time Setting or Adjustment (SET CODE) T I M E 31 Date Setting or Adjustment (SET CODE) D A T E 32 Media Tender Key Setting (SET CODE) T E N D E R 33 Financial Report Item Name Programming (SET CODE) T R A N S . N A M E

OPERATION

CONDITION

(See table below.) Max. 10 characters (See NOTE below.)

Repeat for other messages.

Indicates the end of each item name. (Any unprogrammed parts will be filled with blanks.)

Page 51: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-43

Item Code Item Name/Application Standard Program

34 Print Name (SET CODE) P R I N T N A M E 35 Print Item Name Programming (SET CODE) P R I N T I T E M 36 VAT or Add-on Tax Rate Setting (SET CODE) T A X 37 Department Group Name Programming (SET CODE) D E P T G R O U P 38 Display Upper-row Message Programming (SET CODE) D I S P . N A M E 39 System Option Programming (SET CODE) M A C O P T I O N 40 Endorsement Message Programming (SET CODE) C H E C K M E S S 41 Link PLU Table Programming (SET CODE) L I N K P L U 42 PLU Preset-code Key Setting (SET CODE) C D . P R E . P L U 43 PLU Group Programming (SET CODE) P L U G R O U P 44 Advertisement Message Programming (SET CODE) A D L I N E 45 Report Header Name Programming (SET CODE) M C C A P T I O N 46 Reserved 47 Function Key Setting (SET CODE) F U N C . K E Y 48 PLU Cashier Report Setting (SET CODE) P L U C A S H I E 49 %+ and %- Preset Rate Setting + % , - % 50 Foreign Currency Exchange Rate Setting (SET CODE) F C 51 Amount Charge & Amount Discount Preset Setting (SET CODE) + , - 52 Manager Pass Code Programming (SET CODE) M N G P A S S 53 Network Terminal No. Setting (SET CODE) T E R M I N A L # 54 COM Port Setting (SET CODE) C O M P O R T 55 In-Store Marking Bar Code Programming (SET CODE) I N S T O R E 56 Register No. Setting (SET CODE) M A C # 57 Line Feed Value of Endorsement Message (SET CODE) C H E C K F E E D 58 Rounding Process Setting (SET CODE) R O U N D I N G 59 European Rounding Process Setting (SET CODE) S P R O U N D 60 Date Format Setting (SET CODE) D A T E F O R M 61 Paper Cut Method Setting (SET CODE) P A P E R C U T 62 Printer Stamp Setting (SET CODE) S T A M P 63 Store Coupon, Vender Coupon, Bottle Return Status Programming (SET CODE) C O U P O N 64 Food Stamp Programming (SET CODE) F O O D S T A M P 65 Store Message & Commercial Message Setting 1 H E A D L O G O 66 Cashier Code & Name Programming 1 N A M E 67 Cashier Code & Name Programming 2 P A S S C O D E 68 Cashier Code & Name Programming 3 H A L O / L A L O 69 Cashier Code & Name Programming 4 C O M I T R A T E 70 Cashier Code & Name Programming 5 C O M I T F A C T 71 Cashier Code & Name Programming 6 O P E R A T E S T 72 Cashier Code & Name Programming 7 S U P E R V I S O R 73 Department Table Programming 1 N A M E 74 Department Table Programming 2 P R I C E 75 Department Table Programming 3 T A X N O . 76 Department Table Programming 4 G R O U P N o . 77 Department Table Programming 5 H A L O / L A L O 78 Department Table Programming 6 S T A T U S 1 79 Department Table Programming 7 S T A T U S 2 80 Reserved 81 PLU Table Programming 1 N A M E

Page 52: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-44

Item Code Item Name/Application Standard Program

82 PLU Table Programming 2 P R I C E 1 83 PLU Table Programming 3 P R I C E 2 84 PLU Table Programming 4 P R I C E 3 85 PLU Table Programming 5 T A X N o . 86 PLU Table Programming 6 G R O U P N o . 87 PLU Table Programming 7 L I N K - D E P T 88 PLU Table Programming 8 S T A T U S 89 PLU Table Programming 9 H A L O / L A L O 90 PLU Table Programming 10 L I N K - P L U 1 91 PLU Table Programming 11 L I N K - P L U 2 92 PLU Table Programming 12 L I N K - P L U 3 93 PLU Table Programming 13 S T O C K 94 PLU Table Programming 14 T A R E T A B L E 95 PLU Table Programming 15 U N I T W E I G H 96 Time Setting 1 T I M E 97 Date Setting 1 D A T E 98 Media Tender Key Setting 1 N A M E 99 Media Tender Key Setting 2 H A L O / L A L O

100 Media Tender Key Setting 3 O P E R A T E S T 101 Financial Report Item Name Setting N A M E 102 Print Name Setting N A M E 103 Print Item Name Setting S E L E C T C D 104 VAT or Add-on Tax Rate Setting 1 R A T E 105 VAT or Add-on Tax Rate Setting 2 L I M I T 106 VAT or Add-on Tax Rate Setting 3 B R E A K 107 Department Group Name Setting G R O U P N A M E 108 Display Message Setting N A M E 109 System Option Setting O P T C O D E 110 Endorsement Message Setting C H E C K M E S S 111 Link PLU Table Setting C O D E 112 PLU Preset-code Key Setting P R E S E T P L U 113 PLU Group Name Setting G R O U P N A M E 114 Advertisement Message Setting A D M E S S A G E 115 Report Header Name Setting C A P T I O N 116 Reserved 117 Function Key Setting F U N C . K E Y 118 PLU Cashier Report Setting P L U N o . 119 %+ and %- Preset Rate Setting % R A T E 120 Tax Status T A X N o . 121 Foreign Currency Exchange Rate Setting 1 N A M E 122 Foreign Currency Exchange Rate Setting 2 S T A T U S 123 Foreign Currency Exchange Rate Setting 3 E X C R A T E 124 Amount Charge & Amount Discount Preset Setting 1 P R I C E 125 Amount Charge & Amount Discount Preset Setting 2 H A L O 126 Amount Charge & Amount Discount Preset Setting 3 T A X N o . 127 Manager Pass Code Setting P A S S C O D E 128 Network Terminal No. Setting N E T - I D 129 COM Port Setting 1 C O N N E C T I O N

Page 53: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-45

Item Code Item Name/Application Standard Program

130 COM Port Setting 2 S P D / L E N G T H 131 COM Port Setting 3 P A R I T Y / S T P 132 In-Store Marking Bar Code 1 F L A G 133 In-Store Marking Bar Code 2 F I E L D 1 134 In-Store Marking Bar Code 3 F I E L D 2 135 In-Store Marking Bar Code 4 P R I C E C / D 136 In-Store Marking Bar Code 5 F C # 137 Register No. Setting M A C H I N E # 138 Line Feed Value of Endorsement Message Setting F E E D L I N E 139 Rounding Process Setting R O U N D I N G 140 European Rounding Process Setting S P R O U N D 141 Date Format Setting D A T E F O R M 142 Paper Cut Method Setting P A P E R C U T 143 Printer Stamp Setting S T A M P 144 Store Coupon S T O R E C P N 145 Vender Coupon V E N D E R C P N 146 Bottle Return B O T T L E R T N 147 Food Stamp F O O D S T A M P 148 Reserved 149 Reserved 150 Reserved 151 Reserved 152 Reserved 153 Reserved 154 Bank RAM Error O P T I O N R A M 155 Printer Error P R I N T E R 156 Reserved 157 Function Error I N V A L O P E R 158 Cashier Error C A S H I E R 159 Control Lock Error C T R L L O C K 160 Cashier Key C A S H I E R K Y 161 Reserved 162 Report Request Error R E P O R T R E Q 163 No Cashier Error N O C A S H I E R 164 HALO Error H A L O 165 LALO Error L A L O 166 Reserved 167 Receipt Near End P R P A P E R 1 168 Receipt Paper End R F P A P E R 169 Receipt Head Up P R H E A D U P 170 Journal Near End J P A P E R 1 171 Journal Paper End J F P A P E R 172 Journal Head Up J H E A D U P 173 Reserved 174 Reserved 175 Reserved 176 Code No. Request C O D E # R E Q 177 Sub Total Key Request S U B - T L R E Q

Page 54: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-46

Item Code Item Name/Application Standard Program

178 Amount Tender Request A M O U N T R E Q 179 Drawer Close Request C L O S E D R W 180 Tare 2 (Manual Tare) Entry Request T A R E 2 R E Q 181 Reserved 182 Reserved 183 Reserved 184 Reserved 185 Reserved 186 Reserved 187 Cashier ID Error C A S H I E R I D 188 Reserved 189 Reserved 190 Reserved 191 Reserved 192 Reserved 193 Reserved 194 Reserved 195 Reserved 196 Reserved 197 Reserved 198 Reserved 199 Slip Printer Status Error S P S T A T U S 200 Slip Printer Hardware Error S P E R R O R 201 Slip Printer BUSY S P B U S Y 202 Reserved 203 Reserved 204 Reserved 205 Card Swipe Request for EFT S W I P E C A R D 206 EFT is under process. P R O C E S S I N G 207 No Response from EFT N O R E S P O N S 208 Response NG from EFT R E S P O N S N G 209 EFT was approved. A P P R O V E D 210 Reserved 211 PIN Entry Request for EFT E N T E R P I N # 212 Authorized Code Entry Request for EFT E N T A U T C D 213 Reference No. Entry Request for EFT E N T R E F . N O 214 Card No. Entry Request for EFT E N T C A R D # 215 Expiration Date Entry Request for EFT E X P D A T E 216 Card No. Manual Entry for EFT M A N U A L C D 217 EFT Offline Approval O F F L I N E 218 Amount Entry Request for EFT E N T A M O U N T 219 EFT Cancel E F T C A N C E L 220 PIN Error P I N E R R O R 221 Reserved 222 Age Limit Setting P R E S E T A G E 223 Reserved 224 Scale Tare Weight Setting T A R E W E I G H 225 Reserved

Page 55: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-47

Item Code Item Name/Application Standard Program

226 Scale General Unit Weight Setting U N I T W E I G H 227 Media Tender Setting 2 T E N D E R 2 228 EFT Media Selection E F T M E D I A 229 Media Status Setting M E D I A S T S 230 EFT Timer Setting E F T T I M E R 231 MSR Waiting Time Setting M S R W A I T 232 Card Authorization Waiting Time Setting A U T H W A I T 233 PIN Entry Waiting Time Setting P I N W A I T 234 Debit Sales Response Waiting Time Setting D E B I T W A I T 235 EFT Status Setting E F T S T A T U S 236 Birthday Entry Request for Age Limit C H E C K I D 237 Age Limit NG U N D E R A G E 238 Birthday Setting for Age Limit I D S E T 239 PIN Pad Type Setting for EFT P I N P A D 240 EFT Dial In Load Command is performed. D I A L I N 241 Telephone Number Setting for EFT Dial Out Load P H O N E # 242 Host ID Setting for EFT Dial Out Load H O S T I D 243 Dialing System Setting for EFT Dial Out Load D I A L I N G 244 EFT Dial Out Load Command is performed D I A L O U T 245 EFT Network List Output Command is performed. I N S T . N E T 246 EFT is waiting to be processed. W A I T I N G 247 The scale is weighing an item. W E I G H T 248 Scale Error S C A L E E R R 249 Local Total Report Output L O C A L R E P 250 Clear Current Batch C L R B A T C H

NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Message.

Therefore, odd number of numeric digit entry will cause an error. When less than 20 digits of numeric data are entered, this ECR uses space code entry. If a Message includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Message, up to 10 regular-sized or 5 double-sized characters can be entered. Also a combination of both types can be entered.

2. As shown in the table above, the Standard Program Message is prepared for each Item Code. (which is auto-set after a RAM Clear). Therefore, program only the message that needs to be changed.

3. Item Codes 151 to 204 indicate error messages.

Page 56: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.20 Display Upper-Row Message Programming (Submode 17)

4-48

Example) To program “BALANCE DUE” instead of Standard Program Message “TOTAL” for Item Code 3. Key Operation: Control Lock: SET, Enter 17 and depress the [#/NS] key. [0] [3] [#/NS] (Item Code) [4] [2] (B) [4] [1] (A) [4] [c] (L) [4] [1] (A) [4] [e] (N) [4] [3] (C) [4] [5] (E) [4] [4] (D) [5] [5] (U) [4] [5] (E) [AT/TL] [#/NS] To complete this submode.

���������� �����

35*35* ����

������ %$/$1&('8(

���� �����70

Page 57: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.21 System Option Programming (Submode 18)

4-49

4.21 System Option Programming (Submode 18) The ECR’s basic features and selective functions can be programmed here to meet the requirements of the market and your user. After Financial Daily Reset Control Lock: SET or BLIND 18 [#/NS] |Address No.| [#/NS] |Bit No. for “SET”| |Bit No. for “SET”| [AT/TL] [#/NS] 2 digits (01 to 13) 1 digit (0 to 7) 1 digit (0 to 7) Example) To set Address No.1 according to the following requirements. (Refer to Address No.1 Table on the next page.) Bit No. 3 in Table 1: Tax Symbol Print on Receipt Bit No. 1 in Table 2: Date and Time Print on Receipt Key Operation: Control Lock: SET, Enter 18 and depress the [#/NS] key. [0] [1] [#/NS] (Address No.1) [3] [1] [AT/TL] (Bit No. for “SET”) [#/NS] (To complete this submode.) Address No. 1: : Default setting after RAM clear

Table 1 0 1 2 3 4 5 6 7 Individual tax amount print on receipt O O O O

Amount with tax print on receipt O O O O

Tax symbol print on receipt O O O O

Table 2 0 1 2 3 4 5 6 7 PLU code print on receipt O O O O

Date print on journal and receipt O O O O

Time print on journal and receipt O O O O

Address No. 2:

Table 1 0 1 2 3 4 5 6 7 Register No. print on journal and receipt O O O O

Receipt Consecutive No. print on journal and receipt O O O O

Subtotal amount print on receipt and journal by depressing the [ST] key O O O O

Table 2 0 1 2 3 4 5 6 7 Item count print on journal and receipt O O O O

Logo message print on receipt O O O O

Cashier name print on journal & receipt O O O O

OPERATION

CONDITION

One Address consists of two Bit Nos. According to the requirement, select applicable Bit Nos. from each Table.

Repeat for other system options.

���������� �����

35*35* ����

������ ��

���� �����70

Page 58: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.21 System Option Programming (Submode 18)

4-50

Address No. 3:

Table 1 0 1 2 3 4 5 6 7 Z report counter reset after reset report is issued in “Z” mode O O O O

GTZ report counter reset after reset report is issued in “Z” mode O O O O

GT (Grand Total) reset after reset report is issued in “Z” mode O O O O

Table 2 0 1 2 3 4 5 6 7 Receipt Consecutive No. reset after reset report is issued in “Z” mode O O O O

Amount “0” registration is prohibited. O O O O

Cashier function is unavailable. O O O O

Address No. 4:

Table 1 0 1 2 3 4 5 6 7 Reserved

Post-issue receipt is allowed. O O O O

Check digit is valid at the short barcode setting and entering. (NOTE 1) O O O O

Table 2 0 1 2 3 4 5 6 7 12-hour system O O O O

Cashier No. entry for each transaction (NOTE 2) O O O O

Reserved

NOTES: 1. Valid: When 7-digit-or-below codes are entered manually with the [EAN] key, the check digit will be added automatically.

Invalid: When the short code is entered through the barcode scanner, the check digit will be deleted. When an 8-digit short barcode set with the [X/TIME] key is entered manually with the [EAN] key, the last digit will be regarded as the check digit to be deleted.

2. By selecting this setting, when the transaction is finalized, the cashier will be signed off automatically and the cashier symbol will be cleared. Depressing the [C] key will indicate “LOG” (sign off status) on the upper display.

Address No. 5: Table 1 0 1 2 3 4 5 6 7 Price shift function (“O” indicates as NOTE below shows.) O O O O

Key-in tone is OFF O O O O

Cashier interruption is allowed. O O O O

Table 2 0 1 2 3 4 5 6 7 Money declaration operation is compulsory. O O O O

Correction over the registered amount is prohibited. O O O O

The month name is printed in alphabets. O O O O

NOTE: When the [2nd PRICE] key is pressed, second price level is held until the [1st PRICE] key is pressed.

Page 59: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.21 System Option Programming (Submode 18)

4-51

Address No. 6: Table 1 0 1 2 3 4 5 6 7 Subtotal in Foreign Currency-1 is printed for all time. O O O O

Change in Foreign Currency-1 is printed for all time. O O O O

The rate of Foreign Currency-1 is printed for all time. O O

Table 2 0 1 2 3 4 5 6 7 Subtotal in Foreign Currency-1 is printed. O O O O

Change in Foreign Currency-1 is printed. O O O O

The rate of Foreign Currency-1 is printed. O O O O

Address No. 7: Table 1 0 1 2 3 4 5 6 7 Tax is printed after payment amount print O O O O

VAT/Add-on Tax total is printed. O O O O

Tax rate is printed. O O O O

Table 2 0 1 2 3 4 5 6 7 Logo Header is printed on the receipt and the journal. O O O O

%-, %+, +, - after subtotal within a sale is allowed only once. O O O O

Zero-skip of PLU data when transmitting to PC O O O O

Address No. 8:

Table 1 0 1 2 3 4 5 6 7 Non-add # entries within a receipt is allowed only once. O O O O

No-sale after Non-add # entry is allowed. O O O O

Drawer close is compulsory.(i.e. any registering operation is prohibited at the drawer open.) O O O O

Table 2 0 1 2 3 4 5 6 7 Decimal point in item count and % rate . , . , . , . ,

Amount division symbol . . , , . . , ,

Net total print on sale receipt O O O O

Address No. 9:

Table 1 0 1 2 3 4 5 6 7 US endorsement/FR check compulsory. O O O O

Code No. entry is compulsory before [CHECK No.] key. (US endorsement) O O O O

US endorsement/FR check US US US US FR FR FR FR

Table 2 0 1 2 3 4 5 6 7 Date and Register No. Print on journal (Thailand specification only) O O O O

Power ON/OFF count print on journal O O O O

The [C] key count print on journal O O O O

Page 60: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.21 System Option Programming (Submode 18)

4-52

Address No. 10: Table 1 0 1 2 3 4 5 6 7 Check No. in US endorsement printing O O O O

Date/Time in US endorsement/FR check printing O O O O

Sale total amount in US endorsement printing O O O O

Table 2 0 1 2 3 4 5 6 7 Two-line print of amount in France check print O O O O

REG- mode is prohibited. O O O O

Canadian balance (hourly-range sale without tax) NOTE O O O O

NOTE: Hourly-range total with tax or without tax can be programmed here. Address No. 11:

Table 1 0 1 2 3 4 5 6 7 EU rounding (cash only) O O O O

Reserved Reserved

Table 2 0 1 2 3 4 5 6 7 Cashier LOG-IN/OFF receipt will not be issued. O O O O

The Slip Printer has been installed. O O O O

Initial count is output to the report. (Columbia specification only) O O O O

Address No. 12:

Table 1 0 1 2 3 4 5 6 7 Birthday entry is compulsory when an item with age limit is entered. O O O O

Weight manual entry on the scale item is allowed. (REG mode) O O O O

[RETURN] and [VOID] operations are allowed at the scale weight manual entry. (REG mode)

O O O O

Table 2 0 1 2 3 4 5 6 7 Unit weight selection for scale entry: Kg (blank)/LB (O) (NOTE 1) O O O O

Fraction rounding at the HI-CONE PLU entry: The result is rounded up. (blank)/The unit price is rounded up. (O)

O O O O

The drawer is opened at the Cashier LOG-ON/OFF. (NOTE 2) O O O O

NOTES: 1. When the unit weight is switched, the Tare Table setting will be cleared. 2. By this option setting, the Cashier Interrupt operation will be prohibited, however, the

Supervisor can perform the Interrupt operation. The cashier can be changed with another by LOG-OFF.

Address No. 13:

Table 1 0 1 2 3 4 5 6 7 Journal print/non-print (O) (NOTE 1) O O O O

Narrow print on the journal is performed. (O)/not performed. (NOTE 2) O O

Over-tendering operation by cent in the food stamp transaction is allowed. (NOTE 3)

O O O O

Page 61: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Mar. 31, 2005)

4.22 Endorsement (or France Check Print) Message Programming (Submode 22)

4-53

Table 2 0 1 2 3 4 5 6 7 Print format for AU in the scale entry (in Kg unit system only) (NOTE 4) O O O O

EFT command for Canada is active. (NOTE 5) O O O O

Reserved

NOTES: 1. When this option has been set, the journal print is not performed in any of SET, REG,

- , X, Z, and BLIND modes. When reset, the journal print is performed in any mode. Also the journal print is performed at the RAM clear so that the journal paper should be set beforehand. The [JF] or [JP] key depression is ignored.

2. When this option has been set, narrow-sized characters are printed on the journal only. When reset, standard-sized characters are printed.

3. When this option has been set, the over-tendering by cent in the food stamp transaction is allowed. When reset, this operation is prohibited.

4. When this option has been set, printing is performed in the Australia print format at the scale entry, manual scale entry, scale entry with tare, and manual scale entry with tare.

5. When this option has been set, EFT command for Canada is active. In other words, BUILD GET PIN COMMAND as standard setting is changed to a cash back command while a DEBIT transaction is performed with the EFT terminal.

4.22 Endorsement (or France Check Print) Message Programming (Submode 22)

Endorsement Message or France Check Message printed on a check by the Remote Slip Printer (option) can be programmed here. Endorsement printing will be activated by depressing the [CHECK No.] key after finalizing a sale.

Anytime outside a sale Control Lock: SET 22 [#/NS] |Line No.| [#/NS] Character entry [AT/TL] [#/NS] NOTES: 1. For the France Check, 2-line message will be printed so that the space code entry is required for the

Line No. 3. 2. Entering 2 digits of numeric code provides an alphanumeric character of message. Therefore, odd

number of numeric digit entry will cause an error. When less than 84 digits of numeric data are entered, this ECR uses space code entry. If a message includes spaces at the beginning, entering space code is required at the beginning of data entry. For the message, up to 42 regular-sized or 21 double-sized characters can be entered. Also a combination of both types can be entered.

3. For activating the remote slip printer, perform the two settings as shown below. Step 1: Set Bit No. 2, 3, 6, or 7 in Address 11, Table 2 in the system option programming.

(For details, refer to Section 4.21 System Option Programming (Submode 18)). Address No. 11, Table 2:

0 1 2 3 4 5 6 7

Cashier LOG-IN/OFF receipt will not be issued. O O O O

The Slip Printer has been installed. O O O O

Initial count is output to the report. (Columbia specification only) O O O O

Step 2: Perform the COM port setting. (For details, refer to Section 4.34 COM Port Setting (Submode 41)).

OPERATION

CONDITION

2 digits (01 to 03) (See NOTE 1 below.)

Max. 42 characters (See NOTE 2 below.)

Repeat for other lines.

Page 62: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Mar. 31, 2005)

4.23 Link-PLU Table Programming (Submode 25)

4-54

Example) To program the following Endorsement Message: Key Operation: Control Lock: SET, Enter 22 and depress the [#/NS] key. [0] [1] [#/NS] (Line #1) [f] [f] [5] [4] (T) [f] [f] [4] [5] (E) [f] [f] [4] [3] (C) [2] [0] (Space) [2] [0] (Space) [f] [f] [5] [3] (S) [f] [f] [5] [4] (T) [f] [f] [4] [f] (O) [f] [f] [5] [2] (R) [f] [f] [4] [5] (E)

[AT/TL] (To complete Line #1) [0] [2] [#/NS] (Line #2) [5] [0] (P) [4] [5] (E) [4] [1] (A) [4] [3] (C) [4] [8] (H) [2] [0] (Space) [4] [4] (D) [5] [2] (R) [4] [9] (I) [5] [6] (V) [4] [5] (E) [2] [c] (,)

[2] [0] (Space) [4] [c] (L) [4] [9] (I) [5] [6] (V) [4] [5] (E) [5] [2] (R) [5] [0] (P) [4] [f] (O) [4] [f] (O) [4] [c] (L) [2] [c] (,) [AT/TL] (To complete Line #2) [0] [3] [#/NS] (Line #3) [4] [5] (E) [4] [e] (N) [4] [7] (G) [4] [c] (L) [4] [1] (A) [4] [e] (N) [4] [4] (D)

[AT/TL] (To complete Line #3) [#/NS] (To complete this

submode)

4.23 Link-PLU Table Programming (Submode 25) Anytime outside a sale Control Lock: SET 25 [#/NS] |Link-PLU Table No.| [#/NS] |PLU Code| [AT/TL] [#/NS] Barcode Scanning Example) To program the following Link-PLU Table data.

Link-PLU Table No. 01 02 03 04

Link-PLU Code 01000000010100 01000000020200 01000000030300 01000000040400

Key Operation: Control Lock: SET, Enter 25 and depress the [#/NS] key. 01 [#/NS] 01000000010100 [AT/TL] 02 [#/NS] 01000000020200 [AT/TL] 03 [#/NS] 01000000030300 [AT/TL] 04 [#/NS] 01000000040400 [AT/TL] [#/NS] (To complete this submode)

24-01-2002 #0000 PRGPRG 2222 01-01 TEC STORETEC STORE 01-02 02-01 PEACH DRIVE, LIVERPOOL, 02-02 03-01 ENGLAND 03-02 0031 15:01TM

T E C S T O R E

P E A C H D R I V E , L I V E R P O O L ,

E N G L A N D

OPERATION

CONDITION

24-01-2002 #0000 PRGPRG 2525 01-01 0100000001010002-01 0100000002020003-01 0100000003030004-01 01000000040400 0082 15:03TM

2 digits (01 to 50) Max. 14 digits

Repeat for other tables.

Page 63: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.24 PLU Preset Code Key Setting (Submode 27)

4-55

4.24 PLU Preset-Code Key Setting (Submode 27) To program keys on the ECR Keyboard as PLU Preset-Code Keys, PLU code can be preset to these keys. Anytime outside a sale Control Lock: SET 27 [#/NS] |PLU Code| [KEY] [#/NS] NOTES: 1. If PLU code entry is skipped and a [KEY] is simply depressed in the above sequence,

pre-programmed PLU code of the KEY is displayed. 2. If “0” is entered as PLU code in the above sequence, the KEY is reset. 3. The [KEY] in the above sequence should be set to “3096” in 4.5 SFKC Programming

beforehand. Example) To program the following PLU Codes to required KEYs on the ECR Keyboard. Key Operation: Control Lock: SET, Enter 27, depress the [#/NS] key. 01000000010101 [required key] [#/NS]

4.25 PLU Group Programming (Submode 29) The name of each PLU Group can be programmed here, of which PLU has already been linked to PLU Group in 4.11 PLU Table Programming (Submode 4) .

Anytime outside a sale Control Lock: SET 29 [#/NS] |PLU Group Code| [#/NS] Character entry [AT/TL] [#/NS] NOTE: Entering 2 digits of numeric code provides an alphanumeric character of PLU Group Name.

Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a PLU Group Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the PLU Group Name, up to 18 regular-sized or 9 double-sized characters can be entered. Also a combination of both types can be entered.

OPERATION

CONDITION

Max. 14 digits (Enter through Numeric Keys on the ECR Keyboard. See NOTE 2 below.)

Depress the required key on the ECR Keyboard. (See NOTE 3 below.)

Repeat for other keys.

OPERATION

CONDITION

2 digits (01 to 99) Max. 18 characters (See NOTE below.)

Repeat for other PLU groups (Max. 99 groups).

���������� �����

35*35* ����

��� ��������������

���� �����70

Map Code

0 1 2

#/NS 3

RF JF 4 5 6 7 8 9 10 11 12

13 14 15

C 16 17

X/TIME 18 19 20 21 22 23 24 25 26 27

28 29 30

7 31

8 32

9 33 34 35 36 37 38 39 40 41 42

43 44 45

4 46

5 47

6 48 49 50 51 52 53 54 55 56 57

58 59 60

1 61

2 62

3 63 64 65 66 67 68 69 70 71 72

73 74 75

0 76

00 77

. 78

ST 79 80

AT/TL 81 82 83 84 85 86 87

Page 64: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.25 PLU Group Programming (Submode 29)

4-56

Example) To program the following names to respective Groups. PLU Group 1 PLU Group 2 Key Operation: Control Lock: SET, Enter 29 and depress the [#/NS] key. [0] [1] [#/NS] (PLU Group 1) [4] [7] (G) [5] [2] (R) [4] [f] (O) [4] [3] (C) [4] [5] (E) [5] [2] (R) [5] [9] (Y) [2] [0] (Space) [5] [0] (P) [4] [c] (L) [5] [5] (U) [2] [0] (Space) [4] [7] (G) [5] [0] (P) [2] [0] (Space) [3] [1] (1) [AT/TL] [0] [2] [#/NS] (PLU Group 2) [4] [7] (G) [5] [2] (R) [4] [f] (O) [4] [3] (C) [4] [5] (E) [5] [2] (R) [5] [9] (Y) [2] [0] (Space) [5] [0] (P) [4] [c] (L) [5] [5] (U) [2] [0] (Space) [4] [7] (G) [5] [0] (P) [2] [0] (Space) [3] [2] (2) [AT/TL] [#/NS] To complete this submode.

G R O C E R Y P L U G P 1

G R O C E R Y P L U G P 2

���������� �����

35*35* ����

�����*52&(5< 3/8 *3 �

�����*52&(5< 3/8 *3 �

���� �����70

Page 65: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.26 Advertisement Message Programming (Submode 31)

4-57

4.26 Advertisement Message Programming (Submode 31) An advertisement message (max. 120 characters; 24 characters x 5 lines) to be printed on the footer portion of receipt can be programmed here. Anytime outside a sale Control Lock: SET 31 [#/NS] |Line No.| [#/NS] Character entry [AT/TL] [#/NS] NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Advertisement

Message. Therefore, odd number of numeric digit entry will cause an error. When less than 48 digits of numeric data are entered, this ECR uses space code entry. If an Advertisement Message includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Advertisement Message, up to 24 regular-sized or 12 double-sized characters can be entered. Also a combination of both types can be entered.

2. None of the Advertisement Message is printed on the journal. (V2 and after) Example) To program the following Store Message and Advertisement Message

OPERATION

CONDITION

2 digits (01 to 05) Max. 24 characters (See NOTE below.)

Repeat for other lines.

Line No. 1

Line No. 2

Line No. 3

Line No. 4

Line No. 5

B a r g a i n s a l e s o n e v e r y

T u e s d a y .

C o m e t o s a v e m o n e y !

Page 66: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.26 Advertisement Message Programming (Submode 31)

4-58

Key Operation: Control Lock: SET, Enter 31 and depress the [#/NS] key. [0] [1] [#/NS] (Line #1) [4] [2] (B) [6] [1] (a) [7] [2] (r) [6] [7] (g) [6] [1] (a) [6] [9] (i) [6] [e] (n) [2] [0] (Space) [7] [3] (s) [6] [1] (a) [6] [c] (l) [6] [5] (e) [7] [3] (s) [2] [0] (Space) [6] [f] (o) [6] [e] (n) [2] [0] (Space) [6] [5] (e) [7] [6] (v) [6] [5] (e) [7] [2] (r) [7] [9] (y)

[AT/TL] (To complete Line #1)

[0] [2] [#/NS] (Line #2) [5] [4] (T) [7] [5] (u) [6] [5] (e) [7] [3] (s) [6] [4] (d) [6] [1] (a) [7] [9] (y) [2] [e] (.) [AT/TL] (To complete Line #2) [0] [3] [#/NS] (Line #3) [4] [3] (C) [6] [f] (o) [6] [d] (m) [6] [5] (e) [2] [0] (Space) [7] [4] (t) [6] [f] (o) [2] [0] (Space) [7] [3] (s) [6] [1] (a) [7] [6] (v) [6] [5] (e) [2] [0] (Space) [6] [d] (m) [6] [f] (o) [6] [e] (n) [6] [5] (e) [7] [9] (y) [2] [1] (!)

[AT/TL] (To complete Line #3) [#/NS] (To complete this submode)

���������� �����

35*35* ����

�����%DUJDLQ VDOHV RQ HYHU\�����7XHVGD\������&RPH WR VDYH PRQH\�

���� �����70

Page 67: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.27 Report Header Name Programming (Submode 32)

4-59

4.27 Report Header Name Programming (Submode 32) Report Header Names to be printed on each Report can be programmed here. Anytime outside a sale Control Lock: SET 32 [#/NS] |Item Code| [#/NS] Character entry [AT/TL] [#/NS] NOTES: 1. Entering 2 digits of numeric code provides an alphanumeric character of Report Header

Name. Therefore, odd number of numeric digit entry will cause an error. When less than 48 digits of numeric data are entered, this ECR uses space code entry. If a Report Header Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Report Header Name, up to 24 regular-sized or 12 double-sized characters can be entered. Also a combination of both types can be entered.

2. As shown in the table below, the Standard Program Report Header is prepared for each Item Code. (which is auto-set after a RAM Clear). Therefore, program only the Report Header that needs to be changed.

Read/Reset Report Name Table

Item Code Contents Standard Program

01 Message of stopped Report - - - - S T O P P E D R E P O R T - - - -

02 Hourly Report Header H O U R L Y R E P O R T

03 Cashier Report Header C A S H I E R R E P O R T

04 PLU Report Header P L U R E P O R T

05 Maintenance PLU Report Header S K U P L U R E P O R T

06 Financial Report Header * F I N A N C I A L R E P O R T *

07 Message of PLU Delete * * * * * * P L U D E L E T E * * * * * *

08 Department Programmed Data Read Report Header * * * * * * D E P A R T M E N T * * * * * *

09 System Read Report Header * * * * S Y S T E M P R E S E T * * * * *

10 PLU Programmed Data Read Report Header * * * * * * * * * P L U * * * * * * * * * *

11 Partition hyphens - - - - - - - - - - - -

12 Partition slashes / / / / / / / / / / / / / / / / / / / / / / / /

13 Partition “*****” * * * * * * * * * * * * * * * * * * * * * * * *

14 Key Code Preset Read Report Header K E Y C O D E . . . . . . . . P R E S E T

15 Message of Status Clear S T A T U S - C

16 Message of RAM Clear R A M - C

17 Department Report Header D E P A R T M E N T R E P O R T

18 Memory OK Message . . . . . . M E M O R Y O K . . . . . .

19 Memory Over Message ! ! ! ! ! M E M O R Y O V E R ! ! ! ! !

20 Power Failure * * * * * * P O W E R F A I L * * * * * *

21 Printer Error ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

22 Invoice Message I N V O I C E

23 All Void Message * * A L L V D * *

24 Hold Message * H O L D *

OPERATION

CONDITION

(See Table below.) Max. 24 characters (See NOTE 1 below.)

Repeat for other items.

Indicates the end of each item name. (Any unprogrammed parts will be filled with blanks.)

Page 68: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.27 Report Header Name Programming (Submode 32)

4-60

(Revision Date: Feb. 28, 2003)

Read/Reset Report Name Table (continued)

Item Code Contents Standard Program

25 Recall Message * R E C A L L *

26 Cashier Interrupt Message * I N T E R R U P T *

27 Return Interrupt Message * R E T U R N *

28 Store Message & Commercial Message Dummy Area 1 / / / / / / / / / / / / / / / / / / / / / / / /

29 Store Message & Commercial Message Dummy Area 2

30 Store Message & Commercial Message Dummy Area 3 Y O U R R E C E I P T

31 Store Message & Commercial Message Dummy Area 4

32 Store Message & Commercial Message Dummy Area 5 T H A N K Y O U

33 Store Message & Commercial Message Dummy Area 6

34 Store Message & Commercial Message Dummy Area 7 / / / / / / / / / / / / / / / / / / / / / / / /

35 Data Clear Message D A T A - C

36 Training Header * * * * T R A I N I N G M O D E * * * * *

37 Cashier PLU Report Header C A S H I E R P L U R E P O R T

38 Cashier Report Title C A S H I E R R E P O R T

39 Media-in-drawer Report Header M E D I A I N D R A W E R

40 Log-in * S I G N O N *

41 Log-off * S I G N O F F *

42 Receipt issue * C O P Y *

43 REG- * R E G - *

44 Reserved

45 Reserved

46 Reserved

47 Reserved

48 Reserved

49 Reserved

50 Reserved

51 Reserved

52 Reserved

53 Reserved

54 Merchant Receipt Title Message M E R C H A N T C O P Y

55 Merchant Receipt Signature Line X _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

56 Merchant Receipt Agreement Message Line #1 I A G R E E T O P A Y A B O V E

57 Merchant Receipt Agreement Message Line #2 T O T A L A M O U N T A C C O R D I N G

58 Merchant Receipt Agreement Message Line #3 T O I S S U E R S A G R E E M E N T

59 EFT Report Clear E F T R E P O R T C L E A R

60 Check Encashment Message C A S H I N G . . . . . . . . . . . . . . . . .

Page 69: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.27 Report Header Name Programming (Submode 32)

4-61

Example) To program “****** DATA CLEAR ******” instead of “DATA-C” for Item Code 35. Key Operation: Control Lock: SET, Enter 32 and depress the [#/NS] key. [3] [5] [#/NS] (Item Code) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [0] (Space) [4] [4] (D) [4] [1] (A) [5] [4] (T) [4] [1] (A) [2] [0] (Space) [4] [3] (C) [4] [c] (L) [4] [5] (E) [4] [1] (A) [5] [2] (R) [2] [0] (Space)

[2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*) [2] [a] (*)

[AT/TL] [#/NS] (To complete this

submode)

���������� �����

35*35* ����

�����

∗∗∗∗∗∗ '$7$ &/($5 ∗∗∗∗∗∗

���� �����70

Page 70: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.28 Function Key (Combination Key) Setting (Submode 34)

4-62

4.28 Function Key (Combination Key) Setting (Submode 34) A string of key opeartions can be set on each FUNCTION key ([FUNCTION 1] to [FUNCTION 10] ). Using such programmed [FUNCTION] keys, the operator can eliminate time in various routine operation procedures. (Up to 10 strokes of key operations can be set to each [FUNCTION] key.) Anytime outside a sale Control Lock: SET 34 [#/NS] [FUNCTION] [KEY]………[KEY] [FUNCTION] [#/NS] NOTES: 1. To delete a string of key operations once set on a FUNCTION key, operate as follows. 34 [#/NS] [FUNCTION] [FUNCTION] [#/NS]

2. Neither [C] , [RF] , [JF] nor [FUNCTION] keys can be set in a string of keys in the setting operation above.

Example) To set the following key operation as [FUNCTION 1] key: 100 [DEPT 1] [ST] [AT/TL] Key Operation: Control Lock: SET, Enter 34 and depress the [#/NS] key. [FUNCTION 1] [1] [0] [0] [DEPT 1] [ST] [AT/TL] [FUNCTION 1] [#/NS]

OPERATION

CONDITION

Same key

Repeatable for other FUNCTION keys whose string of keys are to be deleted.

Depress one of the [FUNCTION] keys. (FUNCTION 1 to FUNCTION 10)

Depress the keys to be contained in the key string. (Max. 10 strokes)

Repeat for other FUNCTION keys.

Depress the same FUNCTION key that was depressed at the declaration.

���������� �����

35*35* ����

)&�� ���

'3��)&$�7'��

���� �����70

Page 71: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.29 PLU Cashier Report Setting (Submode 35)

4-63

4.29 PLU Cashier Report Setting (Submode 35) Up to 40 PLUs can be set to output to the Cashier Report. Anytime outside a sale Control Lock: SET 35 [#/NS] |PLU Select No.| [#/NS] |PLU Code| [AT/TL] [#/NS] Barcode Scanning Example) To set the following PLUs to be output to the Cashier Report: No.01: PLU Code 01000000010101 No.02: PLU Code 01000000010102 Key Operation: Control Lock: SET, Enter 35 and depress the [#/NS] key. 01 [#/NS] 01000000010101 [AT/TL] 02 [#/NS] 01000000010102 [AT/TL] [#/NS] NOTE: PLU Select No. indicates Individual Item Record No. which each cashier can manage up to 40

items. When PLUs to be output to the Cashier Report are sold, this setting can be changed only after the issuance of the ALL PLU Reset Report and the PLU Cashier Sales Report.

4.30 %+ and %- Preset Rate Setting (Submode 36) A Preset Rate can be set on each of the [%+] and [%-] keys, one independent rate for each key. Once a rate is preset, the % key will simply be depressed without a prior rate entry to activate the preset rate. If a rate is entered prior to the depression of the key, the entered rate (manual rate) will be activated instead. Anytime outside a sale Control Lock: SET 36 [#/NS] |Key Selection| [#/NS] |Preset Rate| [AT/TL] |Tax Status 1| |Tax Status 2| [AT/TL] [#/NS]

OPERATION

CONDITION

OPERATION

CONDITION

01 or 02 (01: [%+] key 02: [%-] key)

To complete this programming operation.

0.00 to 99.99% (Use the [.] key when a decimal point is contained in the rate.)

2 digits (Enter the codes in numeric values.) (Refer to Tax Status Tables on the next page.)

���������� �����

35*35* ����

����� ������������������� ��������������

���� �����70

2 digits (01 to 40) (See NOTE below.)

Max. 14 digits

Repeat for other PLUs.

Page 72: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.30 %+ and %- Preset Rate Setting (Submode 36)

4-64

Tax Status 1 Table : Default setting after RAM clear 0 1 2 3 4 5 6 7 Tax 1 taxable O O O O

Tax 2 taxable O O O O

Tax 3 taxable O O O O

Tax Status 2 Table 0 1 2 3 4 5 6 7 Tax 4 taxable O O O O

Reserved

Reserved

Example) To program the following rate to each key. [%+] key Rate: 5.00% Tax Status: Non-taxable [%-] key Rate: 10.00% Tax Status: Non-taxable Key Operation: Control Lock: SET, Enter 36 and depress the [#/NS] key. [0] [1] [#/NS] ([%+] key) [5] [.] [0] [0] [AT/TL] (Percent Charge Rate) [0] [0] [AT/TL] (Tax Status (Non-taxable)) [0] [2] [#/NS] ([%-] key) [1] [0] [.] [0] [0] [AT/TL] (Percent Discount Rate) [0] [0] [AT/TL] (Tax Status (Non-taxable)) [#/NS] (To complete this submode.)

���������� �����

35*35* ����

����� ������� ��

����� �������� ��

���� �����70

Page 73: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.31 Foreign Currency Exchange Rate Setting (Submode 37)

4-65

4.31 Foreign Currency Exchange Rate Setting (Submode 37) The rate of each Foreign Currency (corresponding to the [CUR1] to [CUR4] keys) can be set here. By setting a rate on each Foreign Currency Key, reading the sale total and tendering in the foreign currency value will be possible for sale finalization. Anytime outside a sale Control Lock: SET 37 [#/NS] |Currency Key Code| [#/NS] Character entry [AT/TL] |Decimal Point Place for Rate| |Decimal Place for Convert Amount| [AT/TL] |Effective Numeric for Exchange Rate| [AT/TL] [#/NS] NOTE: Entering 2 digits of numeric code provides an alphanumeric character of Currency Name.

Therefore, odd number of numeric digit entry will cause an error. When less than 24 digits of numeric data are entered, this ECR uses space code entry. If a Currency Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the Currency Name, up to 12 regular-sized or 6 double-sized characters can be entered. Also a combination of both types can be entered. When the Media Tender Key Name was programmed in 12 regular-sized characters, up to 11 characters of the Foreign Currency Name is printed, which was programmed in 12 characters.

Conditions given for Domestic and Foreign Currencies (The rate here is simply an example.) Domestic Currency is US dollar: 1.00 EURO = 0.8785 US$ Key Operation: Control Lock: SET, Enter 37 and depress the [#/NS] key. [0] [1] [#/NS] (CUR1) [5] [5] (U) [5] [3] (S) [2] [4] ($) [AT/TL] (to complete character entry) [4] (Decimal point place for Rate) [2] (Decimal point place for Convert Amount) [AT/TL] 8785 [AT/TL] (Rate) [#/NS] (to complete this submode.)

OPERATION

CONDITION

01 to 04 (01: CUR1, 02: CUR2 03: CUR3, 04: CUR4)

Max. 12 characters (See NOTE below.)

1 digit (0 to 8) 1 digit (0 to 3)

6 digits (000000 to 999999)

���������� �����

35*35* ����

����� 86���� ����� ������

���� �����70

Page 74: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.32 + (Amount Charge) and – (Amount Discount) Preset Setting (Submode 38)

4-66

4.32 + (Amount Charge) and – (Amount Discount) Preset Setting (Submode 38)

A Preset Amount can be set on each of the [+] and [-] keys, one independent amount for each key. Once an amount is preset, these keys will simply be depressed without a prior amount entry to activate the preset amount. If an amount is entered prior to the depression of the key, the entered amount (manual amount) will be activated instead. Anytime outside a sale Control Lock: SET 38 [#/NS] |Key Selection Code| [#/NS] |Preset Amount| [AT/TL] |HALO| [AT/TL] |Tax Status 1| |Tax Status 2| [AT/TL] [#/NS] NOTES: 1. HALO (High Amount to be Locked Out) digit 0: No limit 1: 1 digit (0 to 9) 2: 2 digits (0 to 99) 3: 3 digits (0 to 999) 4: 4 digits (0 to 9999) 5: 5 digits (0 to 99999) 6: 6 digits (0 to 999999) 7: 7 digits (0 to 9999999) 2. Tax Status 1 Table : Default setting after RAM clear

0 1 2 3 4 5 6 7 Tax 1 taxable O O O O

Tax 2 taxable O O O O

Tax 3 taxable O O O O

Tax Status 2 Table

0 1 2 3 4 5 6 7 Tax 4 taxable O O O O

Reserved

Reserved

OPERATION

CONDITION

01 or 02 (01: [+] key 02: [-] key)

To complete this programming operation.

Max. 8 digits (0 to 99999999)

1 digit (0 to 7) (See NOTE 1 below.)

2 digits (Enter the codes in numeric values.) (See NOTE 2 below.)

Page 75: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.32 + (Amount Charge) and – (Amount Discount) Preset Setting (Submode 38)

4-67

Example) To program the following amount to each key. [+] key Preset Amount: 0.50 HALO: 3 digits Tax Status: Non-taxable [-] key Preset Amount: 1.00 HALO: 4 digits Tax Status: Non-taxable Key Operation: Control Lock: SET, Enter 38 and depress the [#/NS] key. [0] [1] [#/NS] ([+] key) [5] [0] [AT/TL] (Preset Amount) [3] [AT/TL] (HALO digit) [0] [0] [AT/TL] (Tax Status (Non-taxable)) [0] [2] [#/NS] ([-] key) [1] [0] [0] [AT/TL] (Preset Amount) [4] [AT/TL] (HALO digit) [0] [0] [AT/TL] (Tax Status (Non-taxable)) [#/NS] (To complete this submode.)

���������� �����

35*35* ����

����� ������� ���� ��

����� ������� ���� ��

���� �����70

Page 76: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.33 Manager Pass Code Programming (Submode 39)

4-68

4.33 Manager Pass Code Programming (Submode 39) Manager Pass Code in Z mode or SET mode can be programmed here, which restricts the access to Z and SET modes only for a manager. Anytime outside a sale Control Lock: SET 39 [#/NS] |Mode Code| [#/NS] |Pass Code| [AT/TL] [#/NS] NOTE: If you enter “0000”, the ECR is released from Pass Code System. Example) To program the following Manager Pass Codes. Pass Code in Z mode: 0101 Pass Code in SET mode: 0202 Key Operation: Control Lock: SET, Enter 39 and depress the [#/NS] key. [0] [1] [#/NS] (Z mode) [0] [1] [0] [1] [AT/TL] (Pass Code) [0] [2] [#/NS] (SET mode) [0] [2] [0] [2] [AT/TL] (Pass Code) [#/NS] (To complete this submode.)

4.34 Network Terminal No. Setting (Submode 40) Network Terminal No. can be programmed here, which is required to communicate with PC. Anytime outside a sale Control Lock: SET 40 [#/NS] |Network Terminal No.| [AT/TL] [#/NS] Example) To set Network Terminal No.7. Key Operation: Control Lock: SET, Enter 40 and depress the [#/NS] key. [0] [7] [AT/TL] (Network Terminal No.) [#/NS] (To complete this submode.)

OPERATION

CONDITION

2 digits (01 or 02) 01: Z mode 02: SET mode

4 digits (0000 to 9999)

(See NOTE below.)

Repeat for the other Pass Code.

OPERATION

CONDITION

2 digits (00 to 08)

���������� �����

35*35* ����

����� ��������� ����

���� �����70

���������� �����

35*35* ����

����� ��

���� �����70

Page 77: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Mar. 31, 2005)

4.35 COM Port Setting (Submode 41)

4-69

4.35 COM Port Setting (Submode 41) Detailed setting of 3 COM ports of the ECR can be programmed here. Anytime outside a sale Control Lock: SET 41 [#/NS] |COM Port No.| [#/NS] |Control Code| |Connection| [AT/TL] [#/NS] |Baud Rate| |Data Length| [AT/TL] |Parity Bit| |Stop Bit| [AT/TL] [#/NS]

NOTES: 1. As the table below shows, each port is set as standard after the RAM Clear.

Port No. Port Name Control Code Connection Baud Rate Data Length Parity Bit Stop Bit

01 COM 1 DTR/DSR Barcode Reader 9600 bps 8 bits None 1 stop

02 COM 2 DTR/DSR Slip Printer 9600 bps 8 bits None 1 stop

03 COM 3 DTR/DSR PC Interface 19200 bps 8 bits Odd 1 stop

2. Standard setting values when connecting the EFT terminal and the scale are as shown below, however, they may differ according to the setting of the EFT terminal and the scale.

Device Control Code Connection Baud Rate Data Length Parity Bit Stop Bit

EFT DTR/DSR EFT 2400 bps 8 bits None 1 stop

Scale DTR/DSR Scale 2400 bps 7 bits Even 1 stop

3. When connecting a PC to the ECR, use a PC interface cable as shown below.

MA-1535 PC Interface Cable

D-sub 9pin D-sub 9pin Female Female

2P and 3P cross connection 5P straight connection 7P and 8P short

Example) To program COM Port 02 (COM B) as the following data Control Code: DTR/DSR Data Length: 8 bits Connection: EFT Parity Bit: None Baud Rate: 2400 bps Stop Bit: 1 stop Key Operation: Control Lock: SET, Enter 41 and depress the [#/NS] key. [2] [#/NS] [0] [2] [AT/TL] [3] [1] [AT/TL] [0] [0] [AT/TL] [#/NS] (To complete this submode.)

OPERATION

CONDITION

2 digits (01, 02 or 03) 1 digit (0 or 1) 1 digit (0 to 6) 0: DTR/DSR 0: Not used 1: XON/XOFF 1: PC interface 2: EFT 3: Slip printer 4: Not used 5: Barcode reader 6: Scale

Repeat for the other Pass Code.

1 digit (0 to 3) 1 digit (0 or 1) 0: 4800 bps 0: 7 bits 1: 9600 bps 1: 8 bits 2: 19200 bps 3: 2400 bps

1 digit (0 to 2) 1 digit (0 or 1) 0: None 0: 1 stop 1: Odd 1: 2 stops 2: Even

���������� �����

35*35* ����

����� ��

��� ��

��� ��

���� �����70

COM3

COM2

COM1

2P 3P 5P 7P 8P

2P 3P 5P 7P 8P

Page 78: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Mar. 31, 2005)

4.36 In-Store Marking Bar Code Programming (Submode 42)

4-70

4.36 In-Store Marking Bar Code Programming (Submode 42) In-Store Marking Bar Code can be programmed here. All the settings in this submode should be done before you perform 4.11 PLU Table Programming (Submode 4). Anytime outside a sale Control Lock: SET 42 [#/NS] |Code|* [#/NS] |Flag Code Data|** [AT/TL] |Digit Data of Field 1| [AT/TL] |Data of Field 2| [AT/TL] |Status|*** [AT/TL] |FC Conversion| [AT/TL] [#/NS] *Code: You can set up a maximum of 20 kinds of In-store Marking Codes for Long code and 10 kinds of codes for short code. Long Code: 13-digit code Short Code: Shorten codes such as EAN-8, UPC Short **Flag Code Data: Specify an In-Store code Flag No. ***Status: “With or Without Price Check Digit” and “Multiplying the Unit Price/Weight by 10 or 100” can be set. Select a combination of the three statuses for the In-Store code.

Data 0 1 2 3 4 5 6 7

Price Check Digit Without With Without With Without With Without With

x10 x1 x1 x10 x10 x1 x1 x10 x10

x100 x1 x1 x1 x1 x100 x100 x100 x100

Example) To program the following In-store Marking Bar Code. “2300000016000” of which 1600 indicates $16.00. Key Operation: Control Lock: SET, Enter 42 and depress the [#/NS] key. [0] [1] [#/NS] (Code: Long Code No.01) [2] [3] [AT/TL] (Flag Code) [6] [AT/TL] (Field 1 digit: 6 digits) [0] [AT/TL] (Field 2 data: Amount) [0] [AT/TL] (Status) [0] [AT/TL] (FC Conversion: Domestic) [#/NS] (To complete this submode.)

OPERATION

CONDITION

24-01-2002 #0000 PRGPRG 4242 01-01 002 -02 5 -03 0 -04 1 -05 0 0045 15:33TM

2 digits (01 to 30) 01 to 20: Standard 21 to 30: Shortened

1 digit (2 to 6)

Max. 3 digits (0 to 999)

1 digit (0 to 3) 0: Amount 1: Item Count 2: Coupon (Bottle return) 3: Weight

1 digit (0 to 3) 1 digit (0 to 4) 0: Domestic 1 to 4: Conversion of CUR1 to CUR4

2 3 0 0 0 0 0 0 1 6 0 0 C/D

Long Code (13 digits code)

Flag Code = 23

Field 1 = 6 digits Check Digits

Field 2 = “0” (Amount)

Page 79: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.37 Register No. Setting (Submode 43)

4-71

4.37 Register No. Setting (Submode 43) 4-digit numbers can be set as Register ID No. Once set, it will be printed on journal and every receipt. Anytime outside a sale Control Lock: SET 43 [#/NS] 01 [#/NS] |Register No.| [AT/TL] [#/NS] Fixed Example) To set 1234 as Register No. Key Operation: Control Lock: SET, Enter 43 and depress the [#/NS] key. [0] [1] [#/NS] [1] [2] [3] [4] [AT/TL] [#/NS] (To complete this submode.)

4.38 Line Feed Value of Endorsement Message (Submode 46) The number of line feed for a Check Endorsement can be set here. Anytime outside a sale Control Lock: SET 46 [#/NS] |Line Feed Value| [AT/TL] [#/NS] NOTE: When a value is entered for “Line Feed Value”, printing of data actually starts after feeding

the number of lines of the entered value. Example) To set 5 as Line Feed Value Key Operation: Control Lock: SET, Enter 46 and depress the [#/NS] key. [5] [AT/TL] [#/NS] (To complete this submode.)

OPERATION

CONDITION

4 digits (0000 to 9999)

OPERATION

CONDITION

0 to 11

���������� �����

35*35* ����

����� ����

���� �����70

���������� �����

35*35* ����

����� ��

���� �����70

Page 80: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.39 Rounding Process Setting (Submode 47)

4-72

(Revision Date: Feb. 28, 2003)

4.39 Rounding Process Setting (Submode 47) Anytime outside a sale Control Lock: SET 47 [#/NS] |Rounding Process Code| [AT/TL] [#/NS] NOTES: 1. After RAM Clear, Rounding Process is set to “1: Round off” as standard. 2. The number 0, 1, 2, or 3 entered prior to the Rounding Process Code indicates the

decimal point place for currency. However, the entered number will be neither displayed nor printed during setting.

Example) To set “Round down” as Rounding Process Code Key Operation: Control Lock: SET, Enter 47 and depress the [#/NS] key. [0] [AT/TL] [#/NS] (To complete this submode.)

4.40 Date Format Setting (Submode 49) Date Format of which date is printed on every receipt and journal can be set here. Anytime outside a sale Control Lock: SET 49 [#/NS] |Date Format Code| [AT/TL] [#/NS] NOTE: Date Format is set to “1: MM-DD-YY” as standard after the RAM Clear. Key Operation: Control Lock: SET, Enter 49 and depress the [#/NS] key. [1] [AT/TL] [#/NS] (To complete this submode.)

OPERATION

CONDITION

1 digit (0 to 2) 0: Round down 1: Round off 2: Round up

���������� �����

35*35* ����

����� �

���� �����70

OPERATION

CONDITION

1 digit (0 to 2) 0: DD-MM-YY 1: MM-DD-YY 2: YY-MM-DD

���������� �����

35*35* ����

����� �

���� �����70

Page 81: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.41 Printer Cutting Setting (Submode 51)

4-73

4.41 Printer Cutting Setting (Submode 51) This Submode sets the paper cutting method of receipt on Receipt/Journal Printer. Anytime outside a sale Control Lock: SET 51 [#/NS] |Code| [AT/TL] [#/NS] NOTE: “0: Full Cut” is set as standard after the RAM Clear.

4.42 Store Coupon, Vender Coupon, Bottle Return Taxable Status Programming (Submode 53)

Tax Status for Store Coupon, Vender Coupon, and Bottle Return can be programmed respectively. Anytime outside a sale Control Lock: SET 53 [#/NS] |Code| [AT/TL] |Tax Status 1| |Tax Status 2| [AT/TL] [#/NS] Tax Status 1 Table : Default setting after RAM clear 0 1 2 3 4 5 6 7 Tax 1 taxable O O O O

Tax 2 taxable O O O O

Tax 3 taxable O O O O

Tax Status 2 Table 0 1 2 3 4 5 6 7 Tax 4 taxable O O O O

Reserved

Reserved

Example) To program the following Tax Status. Key Operation: Control Lock: SET, Enter 53 and depress the [#/NS] key. [0] [1] [#/NS] (Store Coupon) [1] [AT/TL] (Non-taxable) [0] [2] [#/NS] (Vender Coupon) [1] [AT/TL] (Non-taxable) [0] [3] [#/NS] (Bottle Return) [0] [0] [AT/TL] (Non-taxable) [#/NS] (To complete this submode.)

OPERATION

CONDITION

1 digit (0 to 2) 0: Full Cut 1: Partial Cut 2: Manual Cut

OPERATION

CONDITION

2 digits (01 to 03) 01: Store Coupon setting 02: Vender Coupon setting 03: Bottle Return setting

2 digits (Enter the codes in numeric values.) (See Tax Status Tables below.)

���������� �����

35*35* ����

����� ������ ������ �

���� �����70

Page 82: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.43 Food Stamp Programming (Submode 54)

4-74

4.43 Food Stamp Programming (Submode 54) The Type of Food Stamp can be programmed here. Anytime outside a sale Control Lock: SET 54 [#/NS] |Type of Food Stamp| [AT/TL] [#/NS] *General type: The customer can pay in food stamps up to the amount of the Food-stampable Total (the sale

portion that can be paid in food stamps) plus its taxes due. **Illinois type: The customer can pay in food stamps up to the amount of the Food-stampable Total, which is

exempted from taxes. (The actual amount paid in food stamps only is exempted from taxes.) ***New Jersey type: The customer can pay in food stamps up to the amount of the Food-stampable Total, which is

exempted from taxes regardless of the actual amount paid in food stamps. NOTE: “0: General type” is set as standard after the RAM Clear. Key Operation: Control Lock: SET, Enter 54 and depress the [#/NS] key. [1] [AT/TL] (Illinois type) [#/NS] (To complete this submode.)

OPERATION

CONDITION

1 digit (0 to 2) 0: General type* 1: Illinois type** 2: New Jersey type*** (See NOTE below.)

���������� �����

35*35* ����

����� �

���� �����70

Page 83: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.44 Age Limit Setting (Submode 55)

4-75

4.44 Age Limit Setting (Submode 55) An Age Limit to purchase items restricted by the programmed age can be set here. Anytime outside a sale Control Lock: SET 55 [#/NS] |Age Limit Code| [#/NS] |Age| [AT/TL] [#/NS] NOTE: For Age setting, the youngest age allowable to the item entry should be set. Example) To set as follows: Age of 18 for Age Limit Code 1 Age of 20 for Age Limit Code 2 Age of 23 for Age Limit Code 3 Age of 30 for Age Limit Code 4 Key Operation: Control Lock: SET, Enter 55 and depress the [#/NS] key. [1] [#/NS] (Age Limit Code 1) [1] [8] [AT/TL] [2] [#/NS] (Age Limit Code 2) [2] [0] [AT/TL] [3] [#/NS] (Age Limit Code 3) [2] [3] [AT/TL] [4] [#/NS] (Age Limit Code 4) [3] [0] [AT/TL] [#/NS] (To complete this submode.)

OPERATION

CONDITION

���������� �����

35*35* ����

����� ������� ������� ������� ��

���� �����70

1 digit (1 to 4) Max. 2 digits (0 to 99)

(See NOTE below.)

Repeat for another code.

Page 84: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102

4.45 Tare Table Setting (Submode 56)

4-76

4.45 Tare Table Setting (Submode 56) In 4.11 PLU Table Programming (Submode 4) , some of Scale-compulsory PLUs may be set with a Tare Table Number. The actual Tare Weight is set to each Tare Table here. Anytime outside a sale Control Lock: SET 56 [#/NS] |Tare Table No.| [#/NS] |Tare Weight| [AT/TL] [#/NS] NOTE: In the lowest digit of the Tare Weight (gram), only the value “0” or “5” can be set. Example) To set Tare Table No. 1 with Tare Weight 0.13 LB: Key Operation: Control Lock: SET, Enter 56 and depress the [#/NS] key. [1] [#/NS] (Tare Table No. 1) [1] [3] [AT/TL] (Tare Weight) [#/NS] (To complete this submode.)

4.46 General Unit Weight Setting (Submode 57) General Unit Weight can be set here so that the Unit Weight may be effective to scale items entered through departments or PLUs without any individual Unit Weight designation. Anytime outside a sale Control Lock: SET 57 [#/NS] |General Unit Weight Code| [AT/TL] [#/NS]

OPERATION

CONDITION

���������� �����

35*35* ����

����� ��

���� �����70

1 digit (1 to 9) X to 999X (gram) or 0 to 999 (LB) (Unit: 1/100 LB or gram Example: Enter 13 for 0.13 LB.)

Repeat for another table.

OPERATION

CONDITION

���������� �����

35*35* ����

����� ��

���� �����70

1 to 11 (Refer to General Unit Weight Code Table below.)

Example) To set General Unit Weight Code 2: Key Operation: Control Lock: SET, Enter 57 and depress the [#/NS] key. [2] [AT/TL] [#/NS]

General Unit Weight Code Table Code LB unit Kg unit

1 1 LB 1 Kg 2 2 LB 2 Kg 3 3 LB 3 Kg 4 4 LB 4 Kg 5 5 LB 5 Kg 6 6 LB 6 Kg 7 7 LB 7 Kg 8 8 LB 8 Kg 9 9 LB 9 Kg

10 1/2 LB 100 g 11 1/4 LB ---

Page 85: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.47 Media Tender Key Setting 2 (Submode 58)

4-77

4.47 Media Tender Key Setting 2 (Submode 58) For the Media Tender Keys programmed in 4.14 Media Tender Key Setting (Submode 8) , access to the EFT can be set in this submode. Anytime outside a sale Control Lock: SET 58 [#/NS] |Media Tender key No.| [#/NS] |EFT Media Selection| [AT/TL] |Media Status 1| |Media Status 2| [AT/TL] [#/NS] Media Status 1 Table : Default setting after RAM clear

0 1 2 3 4 5 6 7 Card No. Manual Entry is allowed. (NOTE 1) O O O O

Authorization in off-line status is allowed. (NOTE 1) O O O O

Signature column is printed. (NOTE 1) O O O O

Media Status 2 Table 0 1 2 3 4 5 6 7 Receipts for the store are issued. (NOTE 2) O O O O

Tender operation is allowed. (NOTE 3) O O O O

Media cashing is allowed. (V2 and after) (NOTE 6) O O O O

NOTES: 1. This status is effective only when “1: Credit” is selected in the EFT Media Selection. 2. This status is effective only when “1: Credit” or “2: Debit” is selected in the EFT Media Selection. 3. This status is always effective regardless of the EFT Media Selection. 4. To select “1: Credit” or “2: Debit”, “Depressing the [ST] key before finalizing by the tender key is required.”

should be selected as Status Code 2 in 4.14 Media Tender Key Sett ing (Submode 8) . 5. For the Media Tender Key which “Credit” is selected as EFT Media, payment must not exceed the sale

amount. 6. When this option status has been set to a Media Tender Key, the cashing operation with this key is available.

With the Media Tender Key to which “1: Credit” has been selected in the EFT Media Selection, the cashing operation cannot be performed even when this option status “Media cashing is allowed.” has been set. When reset, the cashing operation cannot be performed.

Example) To program “Media Tender Key No.8 (CREDIT)” as follows. EFT Media Selection: Credit Media Status: Card No. Manual Entry is allowed. Authorization in off-line status is allowed. Signature column is printed. Receipts for the store are issued. Tender operation is allowed. Key Operation: Control Lock: SET, Enter 58 and depress the [#/NS] key. [0] [8] [#/NS] (Media Tender Key No.) [1] [AT/TL] (EFT Media Selection: Credit) [0] [0] [AT/TL] (Status Codes 1 and 2) [#/NS] (To complete this submode.)

OPERATION

CONDITION

2 digits (03 to 09)

Repeat for other Media Tender Keys.

(To complete this programming operation.)

1 digit (0, 1, or 2) (NOTE 4) 0: Not accessed to the EFT terminal 1: Credit 2: Debit

2 digits (Enter the codes in numeric values.) (See Media Status Tables below.)

���������� �����

35*35* ����

����� ���� ��

���� �����70

Page 86: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.48 EFT Timer and Status Setting (Submode 59)

4-78

4.48 EFT Timer and Status Setting (Submode 59) Time-out values when the ECR has an access to the EFT terminal can be set in this submode. Also the EFT status can be set here. Anytime outside a sale Control Lock: SET 59 [#/NS] |Timer 1 Setting| [AT/TL] |Timer 2 Setting| [AT/TL] |Timer 3 Setting| [AT/TL] |Timer 4 Setting| [AT/TL] |EFT Status 1| |EFT Status 2| [AT/TL] [#/NS] EFT Status 1 Table : Default setting after RAM clear

0 1 2 3 4 5 6 7 Reserved

Reserved

Reserved

EFT Status 2 Table 0 1 2 3 4 5 6 7 Symbol ∗ instead of the card No. and the expiration date is printed at the sale finalization by EFT. (Customer receipt) (NOTE 2)

O O O O

Symbol ∗ instead of the card No. and the expiration date is printed at the sale finalization by EFT. (Customer receipt/Journal) (NOTE 2)

O O O O

Reserved

NOTES: 1. The values of the Timer 1 to Timer 4 indicate the time-out for the ECR. A time-out may

occur on the EFT terminal previous to the ECR, causing an error. When a time-out is performed in the ECR, “NO RESPONS” (if set as a default) will be displayed on the alpha-numeric display.

OPERATION

CONDITION

Time-out value while the MSR enable command is being sent. Max. 2 digits (5 to 60) (Default: 33 seconds)

2 digits (Enter the codes in numeric values.) (Refer to EFT Status Tables below.)

To complete this programming operation.

Time-out value while the ECR is in wait condition. Max. 3 digits (1 to 255) (Default: 90 seconds)

Time-out value while the ECR is receiving PIN Number command. Max. 3 digits (1 to 255) (Default: 65 seconds)

Time-out value while the ECR sends the Debit sales command response. Max. 3 digits (1 to 255) (Default: 5 seconds)

Page 87: Tec ma 1535  program manual

4. PROGRAMMING OPERATIONS EO3-11102 (Revision Date: Apr. 28, 2004)

4.49 PLU Stock Loading or Changing (Submode 90)

4-79

2. When this program option has been set, the card No. and the expiration date are printed as shown below.

Card No.: Numeric values are printed in the lower 4 digits and the symbol ∗ is printed in the other digits.

Expiration date: The symbol ∗ is printed in all the digits instead of numeric values. When reset, all the Card No. and the expiration date will be printed with numeric values. Example) To set the EFT Timer and EFT Status as follows; Timer 1: 30 seconds Timer 2: 60 seconds Timer 3: 45 seconds Timer 4: 5 seconds EFT Status: Account Number is not printed on Receipts. Key Operation: Control Lock: SET, Enter 59 and depress the [#/NS] key. [3] [0] [AT/TL] (Timer 1) [6] [0] [AT/TL] (Timer 2) [4] [5] [AT/TL] (Timer 3) [5] [AT/TL] (Timer 4) [0] [1] [AT/TL] (EFT Status) [#/NS] (To complete this submode.)

4.49 PLU Stock Loading or Changing (Submode 90) This Submode loads or changes the stock quantities of PLUs. Anytime outside a sale Control Lock: X or Z 90 [ST] |PLU Code| [PLU] |Stock Quantity| [R/A] or [LOAN] [ST] [PO] or [PICK-UP] NOTE: PLU programming should be done before this operation. Example) To change the stock quantity of the following PLU. Key Operation: Control Lock: X or Z, Enter 90 and depress the [ST] key. 01000000010101 (PLU Code) [PLU] 20 (Stock Quantity) [R/A] or [LOAN] (When adding the stock quantity.) [ST] (To complete this submode.)

OPERATION

CONDITION

(0.001~9999.999) (When adding the stock quantity.)

(When subtracting the stock quantity.)

Repeat for other PLUs.

���������� �����

35*35* ����

����� ����� ������ ������ ������ ��

���� �����70

Page 88: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102

5.1 Programmed Data Verification in BLIND Mode

5- 1

5. PROGRAMMED DATA VERIFICATION Whenever programming operations are performed, it is recommended to issue Program Verification receipts to check the programmed data before entering any other operation. The print format of each program reading is almost the same as that of the program receipt.

5.1 Programmed Data Verification in BLIND Mode Anytime outside a sale Mode Lock: BLIND

Contents to be printed for verification 1) 90 [#/NS] 01 [AT/TL] [#/NS] -------- RAM Allocation Setting Read 2) 90 [#/NS] 20 [AT/TL] [#/NS] -------- SFKC (Selective Function Key Code) Read 3) 90 [#/NS] 30 [AT/TL] [#/NS] -------- Memory Balance/Tax System Programming Read 4) 90 [#/NS] 40 [AT/TL] [#/NS] -------- EFT Programming Read 1) 2) 3) 4)

OPERATION

CONDITION

���������� �����

66 ����

7$; %$/$1& ��

���� �����70

���������� �����

66 ����

���� )&$� ���� )&������ )&�� ���� )&������ )&�� ���� ������ )&$� ���� ������ ���� ���� ������ '3�� ���� ����

���� ���� ���� 7'������ '3�� ���� �������� )&�� ���� 7'������ )&�� ���� �������� )&�� ���� 7'������ )&�� ���� 7'��

���� �����70

���������� �����

66 ����

3/8�7<3( �'(37 ��3/8 ����&$6+,(5 ��

���� �����70

���������� �����

66 ����

3,1 3$' �3+21(� ����������+267 ,' ��������',$/,1* �

���� �����70

Page 89: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102 (Revision Date: Apr. 28, 2004)

5.2 Programmed Data Verification in X or SET Mode

5- 2

5.2 Programmed Data Verification in X or SET Mode Anytime outside a sale Mode Lock: X or SET 1) Programmed data read for each Submode

• X mode 90 [AT/TL] 01 [#/NS] |Submode No.| [AT/TL] [#/NS]

• SET mode 90 [#/NS] 01 [#/NS] |Submode No.| [AT/TL] [#/NS]

NOTES: 1. Printing will be cancelled by depressing the [C] key during report print. 2. On the cashier programming read report, the pass code assigned to individual cashier is

printed not in X mode but in SET mode. 2) Zone PLU Read

• X mode 90 [AT/TL] 02 [#/NS] |Zone-start PLU Code| [X/TIME] |Zone-end PLU Code| [AT/TL] [#/NS]

• SET mode 90 [#/NS] 02 [#/NS] |Zone-start PLU Code| [X/TIME] |Zone-end PLU Code| [AT/TL] [#/NS] NOTES: 1. Printing will be cancelled by depressing the [C] key during report print. 2. The Zone-end PLU Code must be bigger than the Zone-start PLU Code. Failure to do this

may cause an error.

OPERATION

CONDITION

2 digits (01 to 59)

2 digits (01 to 59)

14 digits 14 digits

14 digits 14 digits

7(& 6725(7(& 6725(

���� 3($&+ '5,9(3+21(� �������

2SHQ ����DP WR ����SP&ORVHG� HYHU\ :HGQHVGD\

���������� �����

;; ����

6(&7,21 ��

����������������� 7RPDWR��� ����

��� ������� ������� ��

��� ����� ����� �

��� ����� ����� ��

��� ����� ������

��������������

Zone-start PLU Code

Zone-end PLU Code

When the report is issued in X mode: X When the report is issued in SET mode: PRG

��� 3RWDWR��� ����

��� ������� ������� ��

��� ����� ����� �

��� ����� ����� ��

��� ����� ������

&/�� ���� �����70

Page 90: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102 (Revision Date: Apr. 28, 2004)

5.2 Programmed Data Verification in X or SET Mode

5- 3

3) Individual PLU Group Read • X mode

90 [AT/TL] 03 [#/NS] |PLU Group Code| [AT/TL] [#/NS]

• SET mode 90 [#/NS] 03 [#/NS] |PLU Group Code| [AT/TL] [#/NS] NOTE: Printing will be cancelled by depressing the [C] key during report print.

2 digits (01 to 99)

2 digits (01 to 99)

����������������� /HPRQ��� ������� ������� ������� ����� ����� ����� ���� ����� ����� ����� ����� �������

����������������� $SSOH��� ������� ������� ������� ����� ����� ����� ���� ����� ����� ����� ����� �������

&/�� ���� �����70

7(& 6725(7(& 6725(

���� 3($&+ '5,9(3+21(� �������

2SHQ ����DP WR ����SP&ORVHG� HYHU\ :HGQHVGD\

���������� �����

;; ����

6(&7,21 ������������������� 7RPDWR��� ������� ������� ������� ����� ����� ����� ���� ����� ����� ����� ����� �������

����������������� 3RWDWR��� ������� ������� ������� ����� ����� ����� ���� ����� ����� ����� ����� �������

����������������� 2UDQJH��� ������� ������� ������� ����� ����� ����� ���� ����� ����� ����� ����� �������

When the report is issued in X mode: X When the report is issued in SET mode: PRG

Page 91: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102

5.2 Programmed Data Verification in X or SET Mode

5- 4

4) Zone Department Read

• X mode 90 [AT/TL] 04 [#/NS] |Zone-start Department Code| [X/TIME] |Zone-end Department Code| [AT/TL] [#/NS]

• SET mode 90 [#/NS] 04 [#/NS] |Zone-start Department Code| [X/TIME] |Zone-end Department Code| [AT/TL] [#/NS] NOTE: Printing will be cancelled by depressing the [C] key during report print.

7(& 6725(7(& 6725(

���� 3($&+ '5,9(3+21(� �������

2SHQ ����DP WR ����SP&ORVHG� HYHU\ :HGQHVGD\

���������� �����

;; ����

6(&7,21 ������� 9(*(7$%/(��� ������� ����� ����� ����� ���� ��

����� )58,7��� ������� ����� ����� ����� ���� ��

����� 0($7��� ������� ����� ����� ����� ���� ��

����� ),6+��� ������� ����� ����� ����� ���� ��

����� '$,5<��� ������� ����� ����� ����� ���� ��

&/�� ���� �����70

Zone-start Department (Department code: 01)

Zone-end Department (Department code: 05)

When the report is issued in X mode: X When the report is issued in SET mode: PRG

Page 92: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102

5.2 Programmed Data Verification in X or SET Mode

5- 5

5) Simple PLU Read In this operation, the following 5 items (PLU Code, PLU Name, Unit Price 1, Unit Price 2, and Unit Price 3) extracted from the PLU read report will be printed out.

• X mode 90 [AT/TL] 05 [#/NS] [AT/TL] [#/NS]

• SET mode 90 [#/NS] 05 [#/NS] [AT/TL] [#/NS] NOTE: Printing will be cancelled by depressing the [C] key during report print.

����������������� 6DOPRQ��� ������� ������� ����

����������������� &RG��� ������� ������� ����

����������������� 6KULPS��� ������� ������� ����

����������������� 0LON�/DUJH 3DFN��� ������� ������� ����

����������������� 0LON�6PDOO 3DFN��� ������� ������� ����

&/�� ���� �����70

7(& 6725(7(& 6725(

���� 3($&+ '5,9(3+21(� �������

2SHQ ����DP WR ����SP&ORVHG� HYHU\ :HGQHVGD\

���������� �����

;; ����

6(&7,21 ������������������� 7RPDWR��� ������� ������� ����

����������������� 3RWDWR��� ������� ������� ����

����������������� 2UDQJH��� ������� ������� ����

����������������� /HPRQ��� ������� ������� ����

����������������� $SSOH��� ������� ������� ����

����������������� %HHI��� ������� ������� ����

����������������� 3RUN��� ������� ������� ����

����������������� 0XWWRQ��� ������� ������� ����

When the report is issued in X mode: X When the report is issued in SET mode: PRG

Page 93: Tec ma 1535  program manual

5. PROGRAMMED DATA VERIFICATION EO3-11102

5.2 Programmed Data Verification in X or SET Mode

5- 6

6) Simple Zone PLU Read

• X mode 90 [AT/TL] 06 [#/NS] |Zone-start PLU Code| [X/TIME] |Zone-end PLU Code| [AT/TL] [#/NS]

• SET mode 90 [#/NS] 06 [#/NS] |Zone-start PLU Code| [X/TIME] |Zone-end PLU Code| [AT/TL] [#/NS] NOTES: 1. Printing will be cancelled by depressing the [C] key during report print. 2. The Zone-end PLU Code must be bigger than the Zone-start PLU Code. Failure to do this

may cause an error.

���������� �����

35* ��

����������������� 3/8����� ������� ������� ����

����������������� 3/8����� ������� ������� ����

���� �����70

14 digits 14 digits

14 digits 14 digits

Page 94: Tec ma 1535  program manual

EO3-11102

1

Revision Record Date (T/I #) Page Section Description

4-20 4.10 Department Table Programming (Submode 3)

CONDITION below (underlined portion) has been added. To change the positive/negative, Hash Department and Age Limit statuses

4-21 4.10 Department Table Programming (Submode 3)

In Scale Status Code Table, Tare 2 (Manual Tare) Entry Compulsion has been unavailable by Codes 2 nor 6 (NOTE 7)

4-25 4.11 PLU Table Programming (Submode 4)

In Scale Status Code Table, Tare 2 (Manual Tare) Entry Compulsion has been unavailable by Codes 2 nor 6 (NOTE 6)

4-36 4.16 Print Item on Reports Setting (Submode 11)

In Print Line Item Name Table, Item Code 74 has been altered.

4-42 4.20 Display Upper-Row Message Programming (Submode 17)

Item Codes 03, 05, 10 to 12, and 14 have been altered to “Reserved”. Item Code 16 has been altered.

4-50 4.21 System Option Programming (Submode 18)

For Address No.4, NOTE2 has been added.

4-60 4.27 Report Header Name Programming (Submode 32)

Item Codes 28 to 34 have been altered.

4-63 4.29 PLU Cashier Report Setting (Submode 35)

NOTE has been added.

4-72 4.40 Date Format Setting (Submode 49)

Default value after the RAM Clear has been changed from “DD-MM-YY” to “MM-DD-YY”.

Feb. 28, 2003 (SVO03A3007)

4-77 4.47 Media Tender Key Setting 2 (Submode 58)

NOTE5 has been added.

4-8 NOTE which describes dead key setting for the SFKC has been added. 4-9

4.5 SFKC (Selective Function Key Code) Programming SFKC 70 [LC OPEN] key has been added to the SFKC Table.

4-17 Range of cashier code has been altered from “01 to 99” to “01 to 40”. 4-18

4.9 Cashier Code and Name Programming (Submode 2) Note for the interruption by the supervisor cashier has been added to

NOTE 4. 4-21 4.10 Department Table

Programming (Submode 3) An option setting “Split Package Pricing is available” has been added to Status 2 Code Table. (NOTE 7)

4-26 4.11 PLU Table Programming (Submode 4)

In the receipt sample, the number of decimals for Address No. 13 has been altered from 2 digits to 3 digits.

4-29 4.14 Media Tender Key Setting (Submode 8)

Default setting after a RAM clear has been added to Status Code Tables. (NOTE 3)

4-33 NOTE 5 has been added. 4-35

4.16 Print Line Item Name Programming (Submode 10) Department Group Subtotal has been added as Item Code 29 in the

Print Line Item Name Table. 4-37 4.17 Print Item on Report Setting

(Submode 11) Print Item Code Table 3: • The option setting “Daily Financial Read Count on Reports” was

deleted. Print Item Code Table 5: • The option setting “Subtotal amount print for individual department

group” has been added. • The default setting has been altered.

4-39 4.18 Tax Table Programming (Submode 12)

Tax rate has become programmable to three decimal places.

4-49 The system option programming has become available in BLIND mode also.

4-50 Default setting for Address No. 4 has been altered. 4-51 Address No. 7, Table 2:

The amount charge (+) and amount discount (-) operations have been added to the second item.

4-52, 4-53

4.21 System Option Programming (Submode 18)

Address No. 13 has been newly added. 4-54 4.23 Link-PLU Table

Programming (Submode 25) PLU code entry through the barcode scanner has become available.

4-57 4.26 Advertisement Message Programming (Submode 31)

NOTE 2 has been added.

4-63 4.29 PLU Cashier Report Setting (Submode 35)

PLU code entry through the barcode scanner has become available.

4-68 4.34 Network Terminal No. Setting (Submode 40)

Range of Network Terminal No. has been altered from “01 to 08” to “00 to 08”.

4-69 4.35 COM Port Setting (Submode 41)

• COM port names have been altered. • Standard setting values when connecting the EFT terminal and the

scale have been added.

Apr. 28, 2004 (SVO04A3020)

4-77 4.47 Media Tender Key Setting 2 (Submode 58)

• The option setting “Media cashing is allowed.” has been added to the Media Status 2 Table. Also the default setting after a RAM clear has been altered.

• NOTE 6 has been added.

Page 95: Tec ma 1535  program manual

EO3-11102

2

Date (T/I #) Page Section Description

4-78, 4-79 4.48 EFT Timer and Status Setting (Submode 59)

• The option settings in the EFT Status 2 Table have been altered. Also the default setting after a RAM clear has been altered.

• NOTE 2 has been added. 5-2 NOTE 2 has been added.

Apr. 28, 2004 (SVO04A3020) (Continued)

5-3 5.2 Programmed Data

Verification in X or SET Mode

In the receipt sample, the number of decimals for Address No. 13 has been altered from 2 digits to 3 digits.

Aug. 26, 2004 (SVO04A3034)

2-1, 2-2 2. SPECIFICATIONS Battery specification has been added.