Tally Specification in MCNP
Presented by:
A. O. Ezzati
Department of Energy Engineering,
Sharif University of Technology
By:
Dr. M. Shahriari
![Page 2: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/2.jpg)
Tallies in MCNP:
The user can instruct MCNP to make various tallies related to :
particle current particle flux energy deposition.
![Page 3: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/3.jpg)
MCNP tallies are normalized to be per starting particle except for a few special cases with
criticality sources. Currents can be tallied as a function of direction
across any set of surfaces, surface segments, or
sum of surfaces in the problem. Charge can be tallied for electrons and positrons
Tallies in MCNP:
![Page 4: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/4.jpg)
Standard Tallies : MCNP provides :
seven standard neutron tallies, six standard photon tallies four standard electron tallies
These basic tallies can be modified by the user
in many ways
![Page 5: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/5.jpg)
Standard Tallies : Tally Mnemonic Description .
F1:N or F1:P or F1:E Surface current F2:N or F2:P or F2:E Surface flux F4:N or F4:P or F4:E Track length estimate of cell flux F5a:N or F5a:P Flux at a point or ring detector F6:N or F6:P or F6:N,P Track length estimate of energy deposition F7:N Track length estimate of fission energy deposition F8:N or F8:P or F8:E Pulse height tally or F8:P,E
![Page 6: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/6.jpg)
Standard tallies :Tally Fn Quantity Fn
Units*Fn
Multiplier*Fn Units
F1 particle E MeV
F2 1/(|| * A) 1/ cm2 E MeV/cm2
F4 Tl / V 1/ cm2 E MeV/cm2
F5 p( ) * exp(-/(2R2 ) 1/ cm2 E MeV/cm2
![Page 7: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/7.jpg)
Standard tallies :Tally Fn Quantity Fn
Units*Fn
Multiplier*Fn Units
F6 Tl * t(E) * H(E) * a/m MeV/g 1.6E-22 Jerk/g
F7 Tl * f(E)* Q *a/m MeV/g 1.6E-22 Jerk/g
F8 pulses E MeV
1 jerk=109 J
![Page 8: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/8.jpg)
Surface Current Tally :
This tally is the number of particles (quantity of energy for *F1) crossing a surface.
The scalar current is related to the flux as :
J(r, E, t, ) =|| (r, E, t , )
dAddtdEtErJFEtA
),,,(1
![Page 9: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/9.jpg)
Surface Flux Tally :
This tally is average particle flux (energy flux for *F2) crossing a surface.
A
dAdtdEtErEF
A
dAdtdEtErF
EtA
EtA
),,(*2*
),,(2
![Page 10: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/10.jpg)
Cell Flux Tally :
This tally is average particle flux (energy flux for *F4) in a volume.
V
dVdtdEtErEF
V
dVdtdEtErF
EtV
EtV
),,(*4*
),,(4
![Page 11: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/11.jpg)
Detector Flux Tally :
A point detector is a deterministic estimate of the particle flux (energy flux for *F5) at a point in a space.
dtdEtErEF
dtdEtErF
Et
Et
),,(*5*
),,(5
![Page 12: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/12.jpg)
Surface and Cell Tallies(tally types 1, 2, 4, 6, and 7)
Simple Form: Fn:pl S1 Sk
General Form: Fn:pl S1 (S2 S3) (S4 S5) S6 S7
n = tally number
pl = N or P or N,P or E
Si = problem number of surface or cell for tallying, or T
Example 1: F2:N 1 3 6 T
Example 2: F1:P (1 2) (3 4 5) 6
Example 3: F371:N (1 2 3) (1 4) T
![Page 13: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/13.jpg)
Detector Tallies (tally type 5)
Form for point detectors: Fn:pl X Y Z Ro
n = tally number.
pl = N for neutrons or P for photons,
X Y Z = location of the detector point.
R= radius of the sphere of exclusion:
in centimeters, if Ro is entered as positive,
in mean free paths, if entered as negative. (Negative entry illegal in a void.)
![Page 14: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/14.jpg)
Detector Tallies (tally type 5)
Form for ring detectors: Fn:pl ao r Ro
n = tally number
a = the letter X, Y, or Z.
pl = N for neutrons or P for photons
ao = distance along axis “a” where the ring
plane intersects the axis.
r = radius of the ring in centimeters. Ro = same meaning as for point detectors, but describes a sphere about the point selected on the ring.
![Page 15: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/15.jpg)
Pulse Height (tally type 8)
Simple Form: Fn:pl S1 Sk
General Form: Fn:pl S1 (S2 S3) (S4 S5) S6 S7
n = tally number
pl = P,E or P,E
Si = problem number of cell for tallying, or T.
1) F8:P, F8:E, and F8:P,E are all equivalent tallies.
2) *F8 is an energy deposition tally
3)+F8 is a charge deposition tally in units of electron charge
4) The pulse height tally is not allowed with neutrons
![Page 16: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/16.jpg)
En Tally Energy Card Form: En E1 Ek
n tally number.
Ei = upper bound (in MeV) of the ith energy bin for tally n.
Default: If the En card is absent, there will be one bin over all energies unless this
default has been changed by an E0 card.
Use: Required if EMn card is used.
Example 1: E2 .1 .5 10 20
Example 2: E0 2 4i 7 or E0 2 3 4 5 6 7
Example 3: E8 0 1E-5 1E-3 1E-1 …
![Page 17: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/17.jpg)
Tn Tally Time Card
Form: Tn T1 Tk
n tally number.
Ti upper bound (in shakes) of the ith time bin for tally n.
Default: If the Tn card is absent, there will be one bin over all times unless this default has been changed by a T0 card.
Use: Required if TMn card is used.
Example: T2 1 1.037 NT
![Page 18: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/18.jpg)
Cn Cosine Card (tally type 1 only)
Form: Cn C1 Ck
n tally number.
Ci upper cosine limit of the ith angular bin for surface current tally n. C1. Ck.
Default: If the Cn card is absent, there will be one bin over all angles unless this default has been changed by a C0 card.
Use: Tally type 1. Required if CMn card is used.
Example: C1 This will tally currents within the angular limits (1) to , (2) to , (3) to , (4) to , (5) to , and (6) to with respect to the positive normal.
![Page 19: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/19.jpg)
EMn Energy Multiplier Card
Form: EMn M1 Mk
n = tally number.
Mi = multiplier to be applied to the ith energy bin.
Default: None.
Use: Requires En card. Tally comment recommended.
Tallies can also be changed to be per unit energy if the entries are
E for each bin.
* TMn and CMn cards are same as EMn with respect to Tn
and Cn Cards
![Page 20: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/20.jpg)
FSn Tally Segment Card (tally types 1, 2, 4, 6, 7)
Form: FSn S1 Sk
n = tally number.
Si = signed problem number of a segmenting surface.
Default: No segmenting.
Use: Not with detectors. May require SDn card.
Advantage: it is not necessary to specify the problem geometry with extra cells just for tallying.
Example 1: F2:N 1
FS2 Example 2: F1:N 1 2 T
FS1 T -3, 3, T over cells 1, 2, T
![Page 21: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/21.jpg)
FQn Print Hierarchy Card
Form: FQn a1 a2 a8
n = tally number
ai = F—cell, surface, or detector
S—segment
M—multiplier
C—cosine
E—energy
T—time
Example: F2:N 2 3
E2 0.1 2 20
FQ2 F E
![Page 22: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/22.jpg)
IMP Cell Importance Cards
Form: IMP:n x1 x2 xi xI
n N for neutrons, P for photons, E for electrons. N,P or P,E or N,P,E is allowed if importances are the same for different particle types.
xi importance for cell i
I number of cells in the problem
Default: If an IMP:P card is omitted in a MODE N P problem, all photon cell importances are set to unity unless the neutron importance is 0. Then the photon importance is 0 also.
Example1: IMP:N 1 1 0, IMP:P 1 0 0
Example2: IMP:N,P 1 1 1 1 1 0
Example3: IMP:N,P 1 4r 0
![Page 23: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/23.jpg)
Precision of Monte Carlo Calculations From CLT :
mx-Sx<E(x)< mx +Sx 68% confidence interval
mx -2Sx<E(x)< mx +2Sx 95% confidence interval
mx -3Sx<E(x)< mx +3Sx 99.7% confidence interval
Estimated Relative Error is defined as: R=Sx / mx ,
therefore :mx(1-R)<E(x)< mx(1+R) 68% confidence interval
![Page 24: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/24.jpg)
Guidelines for Interpreting the Relative Error
Range of R Quality of the Tally .
0.5 to 1 Not meaningful
0.2 to 0.5 Factor of a few
0.1 to 0.2 Questionable
0.10 Generally reliable except for point detector
0.05 Generally reliable for point detector
----------------------------------------
* R2 is proportional to N
* FOM=1/(R2T)
![Page 25: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/25.jpg)
Estimation of Precision For a variable x with PDF f(x) the true answer (or mean) is:
The true mean is estimated by sample mean :
The Variance of population is defined as:
x
![Page 26: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/26.jpg)
Estimation of Precision And the Standard deviation is defined as square root of variance, is seldom known, but can be steamated by Monte Carlo as S
and
The estimated variance of is given by:x
![Page 27: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/27.jpg)
Estimation of PrecisionThe Estimated Relative Error is defined as:
Statistical error Sx can be reduced by :
Making smaller S (variance reduction techniques)
Making large N ( more history run)
![Page 28: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/28.jpg)
Accuracy and Precision The results of Monte Carlo calculations refers only to
statistical error and precision and not to accuracy.
![Page 29: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/29.jpg)
Error Estimation for a bin:
xN
xR
orx
NxxR
NSxSR
therefore
xEppp
functionondistributibinaryfor
xx
)1(
:/)1(
/,/
:
)(,)1(
:2
![Page 30: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/30.jpg)
Relative error for a bin with estimated mean value and N history
N=10 N=20 N=100 N=5000
0.1 0.9487 0.6708 0.0949 0.0424
0.2 0.6325 0.4472 0.0632 0.0283
0.3 0.4830 0.3416 0.0483 0.0216
0.4 0.3873 0.2739 0.0387 0.0173
0.5 0.3162 0.2236 0.0316 0.0141
0.6 0.2582 0.1826 0.0258 0.0115
0.7 0.2070 0.1464 0.0207 0.0093
0.8 0.1581 0.1118 0.0158 0.0071
0.9 0.1054 0.0745 0.0105 0.0047
x
x
![Page 31: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/31.jpg)
CONTINUE - RUN Countinue run is used to continue running histories in
a problem that was terminated earlier, for example with nps 1000 and then to run up to nps 10000.
Command line :
mcnp c i=inp r=runtpe
and in the inp file :
CONTINUE
nps 10000
print 160
![Page 32: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/32.jpg)
Problem Cutoffs NPS n
CTME T (in minute)
CUT:pl T E WC1 WC2 SWTM pl : N, P or E T : time in shake, (1 shake=1E-8 sec) E : lower energy cutoff in MeV WC1 and WC2 : weight cutoffs. SWTM : minimum source weight
Default values: very large(1E+37),0,-0.5,0.25
![Page 33: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/33.jpg)
Problem Cutoffs ELPT:pl x1 x2 x3 … xI pl : N, P or E xi : lower energy cutoff of ‘cell i’ in MeV I : number of cells in problem
![Page 34: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/34.jpg)
Special characters nR : repeat the immediately preceding entry n times nI : insert n linear interpolates between preceding
and following entries. nJ : jump n entry in input card
Examples: IMP:N 1 1 1 1 1 0 IMP:N 1 4r 0 E2 1 1.5 2 2.5 3 3.5 4 4.5 E2 1 6i 4.5 CUT:N 1E+37 0.1 CUT:N j 0.1
![Page 35: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/35.jpg)
Print Output Tables PRINT x x = no entry gives the full output file x = x1 x2 … basic output plus tables x1, x2 ,… x = -x1 –x2 … prints full output except the tables x1,x2,… Example: print 110 120
print -160
1) BASIC tables can not be turned off
2) DEFAULT tables are automatically printed but can be turned off by print card.
![Page 36: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/36.jpg)
Print Output Tables
![Page 37: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/37.jpg)
Print Output Tables
![Page 38: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/38.jpg)
Print Output Tables
![Page 39: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/39.jpg)
Tally Plotting in MCNP
![Page 40: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/40.jpg)
MCPLOT Tally Plotting Commands mcnp inp= filename ixrz
MCNP runs the problem specified in filename and then the prompt mcplot appears for MCPLOT commands. Both cross-section data and tallies can be plotted.
mcnp inp= filename ixz is the most common way to plot cross-section data. The
problem cross sections are read in but no transport occurs.
![Page 41: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/41.jpg)
Parameter–setting Commands TALLY n Define tally n as the current tally.
n is the n on the Fn card in the INP file
RESET aa Reset the parameters of command aa to
their default values. aa can be a parameter setting command, COPLOT, or ALL.
If aa is ALL, the parameters of all parameter–setting commands are reset to their default values.
![Page 42: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/42.jpg)
Titling commands. TITLE n “aa” Use aa as line n of the main title at the
top of the plot. The allowed values of n are 1 and 2. The maximum length of aa is 40 characters.
XTITLE “aa” Use aa as the title for the x axis. YTITLE “aa” Use aa as the title for the y axis. LABEL “aa” Use aa as the label for the current curve..
![Page 43: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/43.jpg)
Commands that specify the form of 2D plots.
LINLIN Use linear x axis and linear y axis. LINLOG Use linear x axis and logarithmic y axis. LOGLIN Use logarithmic x axis and linear y axis. LOGLOG Use logarithmic x axis and log. y axis XLIMS min max YLIMS min max HIST Make histogram plots. PLINEAR Make piecewise–linear plots. BAR Make bar plots. NOERRBAR Suppress error bars.
![Page 44: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/44.jpg)
Tally plotting through MCNP run
MPLOT mcplot commands
Example: mplot tally 4 free e linlin xlims 1 10 noerr
![Page 45: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/45.jpg)
Commands for cross section plotting. XS m Plot a cross section according to the value of m:
Mn a material card in the INP file. Example: XS M15 z a nuclide ZAID. Example: XS 92235.50C.
MT n Plot reaction n of material XS m. PAR p Plot the data for particle type p, where:
p can be n, p, or e of material Mn. COPLOT
Example: mt=-5 XS 82000.02p coplot XS 29000.02p
![Page 46: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/46.jpg)
ENDF/B REACTION TYPESMT Microscopic Cross-Section Description 1 total 2 elastic16 (n,2n)17 (n,3n)18 fission102 (n103 (n,p)107 (n,)
![Page 47: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/47.jpg)
Total cross section (MT=1)
![Page 48: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/48.jpg)
Absorption cross section (MT=-2)
![Page 49: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/49.jpg)
(n,n’) cross section (MT=51)
![Page 50: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/50.jpg)
Pb photon cross sections (MT=-5,-1,-3,-4)
![Page 51: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/51.jpg)
Total photon cross sections for Pb and Cu
![Page 52: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/52.jpg)
Tally Multiplier Card FMn (C m reaction list 1) …
C = multiplicative constant n = tally number m = material number reaction list i = sums and products of ENDF
or special reaction numbers
FM is used to calculate any quantity of the form :
dEEREC m )()(
![Page 53: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/53.jpg)
ENDF and Special FM Reaction Numbers for Neutrons
ENDF MT Special FM Cross section
1 -1 Total
2 -3 Elastic
-2 Total absorption
-4 Average heating number
-6 Total fission
-7 Fission
-8 Fission Q(MeV/fission)
16 (n,2n)
17 (n,3n)
102 (n,)
103 (n,p)
107 (n,)
![Page 54: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/54.jpg)
Special FM Reaction Numbers for Photons and Electrons
Photons Cross section
-5 Total
-1 Incoherent
-2 Coherent
-3 Photoelectric with fluorescence
-4 Pair production
-6 heating number
Electrons Cross section
1 dE/dx electron collision stopping power
2 dE/dx electron radiative stopping power
3 dE/dx total electron stopping power
4 Electron range
5 Electron radiation yield
![Page 55: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/55.jpg)
Duplication of F6 and F7 tallies using FM4 :
Standard F6 and F7 tallies can be duplicated by F4 tallies with appropriate
FM4 cards. The FM4 card to duplicate F6 is
F4:N n
FM4 C M 1 -4For F7 it is
FM4 C M -6 -8C =10-24 x number of atoms per gram
R1 =1 ENDF reaction number for total cross section (barns)
R2 =-4 reaction number for average heating number (MeV/collision)
R1 =-6 reaction number for total fission cross section (barns)
R2 =-8 reaction number for Fission Q (MeV/fission)
![Page 56: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/56.jpg)
Tally Multiplier Card – Attenuator SetFMn (C -1 m px)
C = multiplicative constant
n = tally number
m = material number
px=density times thickness of attenuating material,
atom density if positive, mass density if negative
The attenuator set can include more than one layer:
C -1 m1 px1 m2 px2
In which case the factor is : 2211 pxpxe
![Page 57: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/57.jpg)
Tally Multiplier Card – Attenuator SetThe attenuator set can also be part of a bin set, for example:
F4:N 1
FM4 ((C1 m1 R1)(C2 m2 R2)(C3 -1 m3 px3))
In this case attenuator factor is applied to every bin created by the
multiplier set.
![Page 58: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/58.jpg)
Tally Multiplier examples :F25:N 0 0 0 0
FM25 0.00253 1001 -6 -8
M1001 92238.60 0.9 92235.60 0.1
C=0.00253 atoms per barn.cm (atomic density) of material 1001
M =1001 material number for material being heated
R1 =-6 reaction number for total fission cross section (barn)
R2 =-8 reaction number for fission Q (MeV/fission)
![Page 59: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/59.jpg)
Tally Multiplier examples :F4:n 1
SD4 1
FM4 (-1 1 16: 17) $ bin 1 =(n,2n)+(n,3n) reaction rates
(-1 1 -2) $ bin 2 =capture (n,0n) reaction rate
(-1 1 -6) $ bin 3 =fission reaction rate
M1 92235 -94.73 92238 -5.27
C=-1 means atom density (atoms/barn.cm) in that cell for tally
type 4
![Page 60: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/60.jpg)
Tally Multiplier examples :F4:n 10FM4 (-1 1 (1 -4)(-2))(-1 1 1)M1 6012 1
In this example there are threedifferent tallies, namely
a) -1 1 1 -4 $ neutron heating in MeV/cm3 from 12C in cell 10 b) -1 1 -2 $ neutron absorption (#/ cm3 ) in 12C in cell 10 c) -1 1 1 $ total neutron reaction (#/ cm3 ) in 12C in cell 10
![Page 61: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/61.jpg)
Dose Energy & Dose Function
![Page 62: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/62.jpg)
![Page 63: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/63.jpg)
Macrobodies:
![Page 64: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/64.jpg)
![Page 65: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/65.jpg)
![Page 66: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/66.jpg)
Perturbation
![Page 67: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/67.jpg)
Perturbation
![Page 68: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/68.jpg)
Perturbation
![Page 69: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/69.jpg)
Perturbation
![Page 70: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/70.jpg)
![Page 71: Tally Specification in MCNP Presented by: A. O. Ezzati Department of Energy Engineering, Sharif University of Technology By: Dr. M. Shahriari](https://reader034.vdocuments.mx/reader034/viewer/2022050809/56649d835503460f94a69163/html5/thumbnails/71.jpg)