  • TABLE OF CONTENTS

    TAB 1 Tentative Agenda

    TAB 2 Tentative Order of Discussion

    TAB 3 Standards Task Group Report

    TAB 4 UPC Code Review Task Group Report

    TAB 5 UPC Storm Drainage System Sizing Task Group Report

    TAB 6 Technical Correlating Committee Report

    TAB 7 Uniform Plumbing Code Change Proposals

  • 2013 Uniform Plumbing Code Technical Committee Meetings Sheraton Salt Lake City, Salt Lake City, UT

    April 29 - May 1, 2013 AGENDA

    I. Call to order

    II. Chairman Comments

    III. Announcements

    IV. Self Introductions

    V. Review and Approval of Agenda

    VI. Approval of Minutes - Previous Meeting (Via Teleconference on May

    10, 2012)

    VII. Consideration of Standards Task Group Report

    VIII. Consideration of UPC Code Review Task Group Report

    IX. Consideration of Storm Drainage System Sizing Task Group Report

    X. Consideration of Technical Correlating Committee Report

    XI. Discussion of Code Change Proposals to the Uniform Plumbing Code

    XII. Other Business

    XIII. Future Meetings

    XIV. Adjournment

  • TENTATIVE ORDER OF DISCUSSION 2013 PROPOSED CODE CHANGES TO THE UNIFORM PLUMBING CODE

    The following is the tentative order of discussion on which the proposed changes will be discussed at the Technical Committee Meeting. Proposed code changes that are grouped together are those that are both indented and separated by lines. Indented proposed code changes are those being discussed out of numerical order. Item # 001

    Item # 002 Item # 004 Item # 006 Item # 008 Item # 009 Item # 010 Item # 011 Item # 012 Item # 013 Item # 014 Item # 015 Item # 021 Item # 031 Item # 033 Item # 034 Item # 035 Item # 041 Item # 047 Item # 057 Item # 063 Item # 153 Item # 156 Item # 157 Item # 166 Item # 299 Item # 302 Item # 306 Item # 343 Item # 359 Item # 360 Item # 361 Item # 363 Item # 364 Item # 005 Item # 017

    Item # 003 Item # 007 Item # 016 Item # 018 Item # 019

    Item # 020 Item # 022 Item # 023 Item # 024 Item # 025 Item # 026

    Item # 027 Item # 347 Item # 350 Item # 351 Item # 367 Item # 368

    Item # 028 Item # 029 Item # 270

    Item # 030 Item # 032 Item # 036 Item # 037 Item # 038 Item # 039 Item # 040 Item # 042 Item # 043

    Item # 044 Item # 045 Item # 046 Item # 225 Item # 245

    Item # 048 Item # 049 Item # 050 Item # 051 Item # 052 Item # 053 Item # 054

    Item # 055 Item # 056

    Item # 058 Item # 059 Item # 060

    Item # 061 Item # 062

    Item # 064 Item # 265

    Item # 065 Item # 066

    Item # 067 Item # 068

    Item # 069 Item # 070 Item # 071 Item # 072

    Item # 073 Item # 074 Item # 147

    Item # 075 Item # 076 Item # 077

    Item # 078 Item # 079 Item # 112 Item # 080 Item # 081 Item # 083 Item # 084 Item # 114 Item # 082 Item # 085

    Item # 086 Item # 087 Item # 088

    Item # 089 Item # 143 Item # 090 Item # 139

    Item # 091 Item # 092 Item # 093 Item # 094 Item # 095

    Item # 096 Item # 097 Item # 098

    Item # 099 Item # 100

    Item # 101 Item # 236

    Item # 102 Item # 103 Item # 104 Item # 105 Item # 106 Item # 107 Item # 108 Item # 109 Item # 110 Item # 111 Item # 113

    Item # 115 Item # 116 Item # 117 Item # 118 Item # 119

    Item # 120 Item # 121 Item # 122

    Item # 123 Item # 124

    Item # 125 Item # 126 Item # 127 Item # 128 Item # 129

    Item # 130 Item # 131

    Item # 132 Item # 133

    Item # 134 Item # 135 Item # 136

  • Item # 137 Item # 138 Item # 140 Item # 141 Item # 142 Item # 144 Item # 145 Item # 146 Item # 148 Item # 149 Item # 150 Item # 151 Item # 152

    Item # 154 Item # 155

    Item # 158 Item # 159 Item # 160

    Item # 161 Item # 162

    Item # 163 Item # 164 Item # 165

    Item # 167 Item # 168 Item # 169 Item # 170 Item # 171 Item # 172 Item # 173 Item # 174 Item # 175 Item # 176 Item # 177 Item # 178

    Item # 179 Item # 198

    Item # 180 Item # 181 Item # 182 Item # 183 Item # 184 Item # 185 Item # 186 Item # 187 Item # 188 Item # 189 Item # 190 Item # 191

    Item # 192 Item # 193

    Item # 194

    Item # 195 Item # 196 Item # 197 Item # 199 Item # 200 Item # 201 Item # 202 Item # 203 Item # 204 Item # 205 Item # 206 Item # 207 Item # 208 Item # 209

    Item # 210 Item # 211

    Item # 212 Item # 213 Item # 214 Item # 215

    Item # 216 Item # 217

    Item # 218 Item # 219 Item # 220 Item # 221 Item # 222 Item # 223

    Item # 224 Item # 231 Item # 233

    Item # 226 Item # 227 Item # 228 Item # 229 Item # 230 Item # 232 Item # 234 Item # 235 Item # 237 Item # 238 Item # 239 Item # 240 Item # 241 Item # 242 Item # 243 Item # 244 Item # 246 Item # 247 Item # 248 Item # 249 Item # 250 Item # 251

    Item # 252 Item # 253 Item # 254 Item # 255 Item # 256 Item # 257 Item # 258 Item # 259 Item # 260 Item # 261

    Item # 262 Item # 264

    Item # 263 Item # 266 Item # 267 Item # 268 Item # 269 Item # 271

    Item # 272 Item # 273 Item # 274 Item # 275 Item # 358

    Item # 276 Item # 277 Item # 278 Item # 279 Item # 280 Item # 281 Item # 282

    Item # 283 Item # 285

    Item # 284 Item # 286 Item # 287 Item # 288 Item # 289 Item # 290

    Item # 291 Item # 292 Item # 293 Item # 294

    Item # 295 Item # 296 Item # 297 Item # 298 Item # 300 Item # 301 Item # 303 Item # 304 Item # 305 Item # 307

    Item # 308 Item # 309 Item # 311 Item # 312 Item # 313 Item # 315 Item # 317 Item # 318 Item # 319 Item # 320 Item # 321 Item # 322 Item # 323 Item # 325 Item # 326 Item # 327 Item # 328 Item # 329 Item # 330 Item # 331

    Item # 310 Item # 314 Item # 316 Item # 324

    Item # 332 Item # 333 Item # 334 Item # 335 Item # 336 Item # 337 Item # 338 Item # 339 Item # 340 Item # 341 Item # 342

    Item # 344 Item # 345 Item # 346 Item # 348 Item # 349 Item # 352 Item # 353 Item # 354 Item # 355

    Item # 356 Item # 357

    Item # 362 Item # 365 Item # 366 Item # 369

  • IAPMO Standards Task Group Report

    In accordance with the scope of the Standards Task Group as approved by the applicable Technical Committees, the recommendations for referencing standards in the 2012 Uniform Plumbing Code (UPC), 2012 Uniform Mechanical Code (UMC), 2012 Uniform Swimming Pool, Spa and Hot Tub Code (USPSHTC) and 2012 Uniform Solar Energy & Hydronics Code (USEHC) are as follows:

    1. Two separate standards tables should be included in the code. One for mandatory standards (mandatory standards as defined in accordance with IAPMOs Rules and Regulations) and one for nonmandatory (guidelines, periodicals, handbooks, etc.). Nonmandatory standards should be located in the appendices. The Nonmandatory Standards Table should not contain references to sections of the code. A section should be added to the Nonmandatory Standards Table that states that approval of such standards should be in accordance with the Authority Having Jurisdiction.

    Substantiation: The task group wants to clarify standards that are mandatory and enforceable versus nonmandatory. Section 3-3.7.2 of the Regulations of Committee Projects indicates that nonmandatory standards shall only be referenced as nonmandatory standards and shall only be included as advisory material in an IAPMO Code or Standard. Placing nonmandatory standards in the appendices will avoid such standards from being referenced in the enforceable chapters of the code. The standards shown in bold and italicized font within the referenced standards table of each 2012 IAPMO ANSI code was not clear to whether such standards were mandatory or nonmandatory.

    2. Remove all references to nonmandatory standards from the body of the code.

    Substantiation: Logical follow-up to Recommendation #1.

    3. Reference the appropriate mandatory standards within the body of code.

    Substantiation: Section 3-3.7.1.1 through Section 3-3.7.1.3 of the Regulations of Committee Projects indicate the criteria used to determine Mandatory Referenced Standards. This is a logical follow-up to Recommendation #1.

    4. A charging statement should be added to Chapter 3 indicating the following: Standards cited in this code shall

    be considered part of the requirements of this code and shall be those standards referenced in Table XXXX.X., and the following redundant text should be deleted: A list of accepted plumbing material standards is referenced in Table XXXX.X.

    Substantiation: This is a statement that is already indicated in the referenced standard table chapters of IAPMOs (4) ANSI codes and should be brought forward to Chapter 3 to provide clear direction to the end user.

    5. The charging statement should be revised in the referenced standards chapter of each code as follows:

    XXXX.X Mandatory Standards. Table XXXX.X lists the mandatory standards that are referenced in this code. The standards are indentified by the name of the developing organization, title, and date or edition. The application of the referenced standards shall be as specified in Section 3XX.X

    A charging statement should be added in the appendices of each code for the Nonmandatory Standards Table as follows: XXXX.X Nonmandatory Standards. Table XXXX.X lists nonmandatory standards and guidelines that are used in the industry. Substantiation: The charging statement located in the referenced standards table of each of IAPMOs ANSI codes should be revised to clarify the intent of the Mandatory Standards Table, and a charging statement should be added for the Nonmandatory Standards Table to clarify its intent as well. These charging statements are consistent with the actions taken on Recommendation #4.

  • 1

    2015 UPC CODE REVIEW TASK GROUP The scope of this group is to identify and review issues that have been brought forth by membership and industry, in regards to the 2012 UPC, in an attempt to make the code more user-friendly. The recommendations, along with a report of underlying issues, will be forwarded to the UPC Technical Committee for review. Item #1 RECOMMENDATION: Add new text as follows: 203.0 Accepted Engineering Practice. That which conforms to technical or scientific-based principles, tests, or standards that are accepted by the industry. SUBSTANTIATION: The term accepted engineering practice is used in Sections 309.1, 501.1, 911.1, 1208.7.5.1, 1314.1, and E 35.1 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Accept as Submitted Item #2 RECOMMENDATION: Revise text as follows: 203.0 Authority Having Jurisdiction. The organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, installations, or procedures. The Authority Having Jurisdiction shall may be a federal, state, local, or other regional department or an individual such as a plumbing official, mechanical official, labor department official, health department official, building official, or others having statutory authority. In the absence of a statutory authority, the Authority Having Jurisdiction may be some other responsible party. This definition shall may include the Authority Having Jurisdictions duly authorized representative. SUBSTANTIATION: In accordance with the Manual of Style, definitions should not be written in mandatory language. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The concern is that by changing shall to may that the definition could be interpreted that anyone could be considered an Authority Having Jurisdiction. The task group believes that all of the text except the first sentence of the definition could be relocated to Section 102.1 to satisfy the concerns of the group, and meet the requirements of the IAPMO Manual of Style.

  • 2

    Item #3 RECOMMENDATION: Revise text as follows: 204.0 Branch Interval. A length of soil or waste stack corresponding in general to a story height, but in no case less than 8 feet (2438 mm), within which the horizontal branches from one floor or story of the building are connected to the stack. C 5.0 Drainage System Sizing. C 5.1 Definition. For the purposes of this code, this definition shall apply to this appendix: Branch Interval. A length of soil or waste stack corresponding in general to a story height, but in no case less than 8 feet (2438 mm), within which the horizontal branches from one floor or story of the building are connected to the stack. (renumber remaining sections) SUBSTANTIATION: The term branch interval is not only used in Appendix C, but Section 703.2 as well. Therefore, the definition should be relocated to Chapter 2. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: Even though Section 703.2 includes the text branch interval, the task group believes this was done in error as Table 703.2 has nothing to do with branch intervals. Therefore, the definition should remain in Appendix C. Item #4 RECOMMENDATION: Add new text as follows: 205.0 Cleanout. An access opening that facilitates the removal of an obstruction. SUBSTANTIATION: The term cleanout is used in Sections 316.1, 317.1, 509.5.6.2, 509.5.9, 707.0, 710.1, 712.1, 719.0, 801.2.2, 803.1, 909.1, 910.6, 1002.3, 1008.1, 1017.1, 1101.12, 1103.4, 1109.2, B 1.0, C 7.7, E 10.1, and E 70.0 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The term cleanout is well known throughout the industry, and therefore a definition is not necessary. Furthermore, the proposed definition is too limiting as defined.

  • 3

    Item #5 RECOMMENDATION: Add new text as follows: 205.0 Combination Temperature and Pressure-Relief Valve. A relief valve that actuates when a set temperature or pressure is reached. SUBSTANTIATION: The term temperature and pressure relief valve is used in Sections 505.2 and 608.3 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Accept as Modified 205.0 Combination Temperature and Pressure-Relief Valve. A relief valve that actuates when a set temperature, or pressure, or both is reached. Also known as a T&P Valve. Item #6 RECOMMENDATION: Add new text as follows: 205.0 Common Vent. A plumbing vent that serves more than one fixture and connects at the junction of the fixture drains. SUBSTANTIATION: The term common vent is used in Sections 908.1, 908.2, and Appendix C without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: A definition is not needed as other sections of the code clearly explain the meaning of a common vent (ex: Section 905.6). Furthermore, the term can be used differently based on application, and therefore cannot be easily defined. Item #7 RECOMMENDATION: Add new text as follows: 206.0 Drainage Fixture Unit (DFU). A measure of the probable discharge of plumbing fixtures into the drainage system. The measure is based on the rate of discharge from the fixtures; the duration of the discharge; and the average time between uses. SUBSTANTIATION: The term drainage fixture unit is used in Sections 702.1, 702.2, 908.2.2, 1014.3.6, C 4.1, C 4.3, C 5.2, C 5.3, C 5.4, C 6.1, C 7.4, C 9.2, and E 9.1 without being defined. The proposed definition assists the end

  • 4

    user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The proposed definition is inaccurate as a DFU is not a measurement, but a unit-less rating. Item #8 RECOMMENDATION: Revise text as follows: 206.0 Drainage System. Includes all the piping within public or private premises that conveys sewage, storm water, or other liquid wastes to a legal point of disposal, but does not include the mains of a public sewer system or a public sewage treatment or disposal plant. SUBSTANTIATION: The addition of storm water to the definition for drainage system will provide correlation with the terminology used throughout Chapter 11 and Appendix D. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The intent of the definition for drainage system is applicable to sanitary drainage systems only, and therefore storm water should not be included in the definition. Item #9 RECOMMENDATION: Add new text as follows: 207.0 Expansion Joint. An arrangement of piping that permits the contraction and expansion of a piping system. SUBSTANTIATION: The term expansion joint is used in Sections 705.10 and 1101.4 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Accept as Modified Expansion Joint. An fitting or arrangement of piping that permits the contraction and expansion of a piping system.

  • 5

    Item #10 RECOMMENDATION: Add new text as follows: 208.0 Faucet. A valve end of a water-supply pipe by which water can be drawn from or held within the pipe. SUBSTANTIATION: The term faucet is used in Sections 403.4, 417.0, and 420.2 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The term faucet is well known throughout the industry, and therefore a definition is not necessary. Item #11 RECOMMENDATION: Delete text without substitution: 218.0 Provision for Location of Point of Delivery. The location of the point of delivery shall be acceptable to the serving gas supplier. [NFPA 54:5.2] SUBSTANTIATION: The term provision for location of point of delivery is not a definition, and in fact this extraction is duplicated in Chapter 12 (Section 1208.2). For informational purposes only, Section 1208.2 is shown as follows: The location of the point of delivery shall be acceptable to the serving gas supplier. [NFPA 54:5.2] TASK GROUP ACTION: Accept as Submitted Item #12 RECOMMENDATION: Add new text as follows: 221.0 Sump Pump. A pump that works automatically to remove the contents of a sump pit. SUBSTANTIATION: The term sump pump is used in Sections 805.1 and 1101.5 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Accept as Modified Sump Pump. A pump that works automatically to removes the contents of a sump or pit.

  • 6

    Item #13 RECOMMENDATION: Add new text as follows: 222.0 Toilet Facility. A room or space that contains not less than one water closet and one lavatory. SUBSTANTIATION: The term toilet facility is used throughout Section 422.0 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards. TASK GROUP ACTION: Accept as Modified Toilet Facility. A room or space that contains fixtures designed for the elimination of human waste and hand washing not less than one water closet and one lavatory. Item #14 RECOMMENDATION: Delete text without substitution: 223.0 Unconfined Space. A room or space having a volume equal to not less than 50 cubic feet per 1000 Btu/h (4.83 m3/kW) of the aggregate input rating of all fuel-burning appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. SUBSTANTIATION: The definition for unconfined should be deleted as the term is not used anywhere within the UPC. The deletion is in accordance with the IAPMO Manual of Style that requires that all definitions in Chapter 2 be referenced elsewhere within the code. TASK GROUP ACTION: Accept as Submitted Item #15 RECOMMENDATION: Add new text as follows: 225.0 Water Outlet. An opening from which water is supplied to a fixture through the atmosphere, to a boiler or heating system, or to any other device or equipment that requires water to operate that is not a part of the plumbing system. SUBSTANTIATION: The term water outlet is used in Sections 603.5.7, 603.5.11, 603.5.18, 608.2, 1603.11.2.2, 1604.12.2.2, 1702.9.6, 1702.11.2.2, E 61.0, E 78.1, K 104.5, and L 504.5 without being defined. The proposed definition assists the end user in applying and enforcing this term, and is consistent with terminology used in other industry standards.

  • 7

    TASK GROUP ACTION: Accept as Modified Water Outlet. An opening from which water is supplied to a fixture through the atmosphere, to a boiler or heating system, or to any other device or equipment that requires water to operate that is not a part of the plumbing system. Item #16 RECOMMENDATION: Revise text as follows: 301.0 General. 301.1 Applicability. This chapter shall govern the general requirements, not specific to other chapters, for the installation of plumbing systems. (renumber remaining sections) 401.0 General. 401.1 Applicability. This chapter shall govern the materials and installation of plumbing fixtures, including faucets and fixture fittings, and the minimum number of plumbing fixtures required based on occupancy. (renumber remaining sections) 601.0 Hot and Cold Water Required. General. 601.1 Applicability. This chapter shall govern the materials, design, and installation of water supply systems, including methods and devices used for backflow prevention. 601.1 General. 601.2 Hot and Cold Water Required. Except where not deemed necessary for safety or sanitation by the Authority Having Jurisdiction, each plumbing fixture shall be provided with an adequate supply of potable running water piped thereto in an approved manner, so arranged as to flush and keep it in a clean and sanitary condition without danger of backflow or cross-connection. Water closets and urinals shall be flushed by means of an approved flush tank or flushometer valve. Exception: Listed fixtures that do not require water for their operation and are not connected to the water supply.

    In occupancies where plumbing fixtures are installed for private use, hot water shall be required for bathing, washing, laundry, cooking purposes, dishwashing or maintenance. In occupancies where plumbing fixtures are installed for public use, hot water shall be required for bathing and washing purposes. This requirement shall not supersede the requirements for individual temperature control limitations for public lavatories, bidets, bathtubs, whirlpool bathtubs and shower control valves. (renumber remaining sections) 701.0 General. 701.1 Applicability. This chapter shall govern the materials, design, and installation of sanitary drainage systems and building sewers. (renumber remaining sections) 801.0 General. 801.1 Applicability. This chapter shall govern the materials, design, and installation of indirect waste piping, receptors, and connections; and provisions for discharge and disposal of condensate wastes, chemical wastes, industrial wastes, and clear water wastes. (renumber remaining sections) 901.0 General. 901.1 Applicability. This chapter shall govern the materials, design, and installation of plumbing vent systems.

  • 8

    (renumber remaining sections) 1001.0 General. 1001.1 Applicability. This chapter shall govern the materials, design, and installation of traps and interceptors. (renumber remaining sections) 1101.0 General. 1101.1 Applicability. This chapter shall govern the materials, design, and installation of storm water drainage systems. (renumber remaining sections) 1202.0 1201.0 General. 1202.1 Installation 1201.1 Applicability. The regulations of this chapter shall govern the installation of fuel gas piping in or in connection with a building, structure or within the property lines of premises up to 5 pounds-force per square inch (34 kPa), other than service pipe. Fuel oil piping systems shall be installed in accordance with NFPA 31. 1201.0 Scope of Gas Piping. (renumber remaining sections) A 1.0 General. A 1.1 Applicability. This appendix provides a general procedure for sizing a water supply system. Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water supply pipes in an appendix, which shall necessarily be limited in length. For a more adequate understanding of the problems involved, refer to Water-Distributing Systems for Buildings, Report BMS 79 of the National Bureau of Standards; and Plumbing Manual, Report BMS 66, also published by the National Bureau of Standards. The following is a suggested order of procedure for sizing the water supply system. (renumber remaining sections) B 1.0 General. B 1.1 Applicability. This appendix provides general guidelines for the design and installation of a combination waste and vent system. (renumber remaining sections) D 1.0 Roof Drainage General. D 1.1 General Applicability. This appendix provides general guidelines for the sizing of storm water drainage systems based on maximum rates of rainfall for various cities. The rainfall rates in Table D 1.1 shall be permitted to be used for design unless higher values are established locally. (renumber remaining sections)

    APPENDIX G SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH

    TYPE B VENTS G 1.0 General. G 1.1 Applicability. This appendix provides general guidelines for sizing venting systems serving appliances equipped with draft hoods, Category I appliances, and appliances listed for use with Type B vents.

  • 9

    (renumber remaining sections) H 1.0 Private Sewage Disposal General. H 1.1 Applicability. This appendix provides general guidelines for the materials, design, and installation of private sewage disposal systems. (renumber remaining sections) J 1.0 General. J 1.1 Applicability. This appendix provides general guidelines for the sizing of combination indoor and outdoor combustion and ventilation air openings. (renumber remaining sections) SUBSTANTIATION: In accordance with the Manual of Style, a section that outlines the purpose or relevancy for a chapter or appendix should be included to assist the end user in the application and enforcement of the code. The chapters and appendices not addressed above already have sections that outline the purpose or relevancy of the chapter or appendix. TASK GROUP ACTION: Accept as Submitted Item #17 RECOMMENDATION: Delete text without substitution: 301.1.3 Existing Buildings. In existing buildings or premises in which plumbing installations are to be altered, repaired, or renovated, the Authority Having Jurisdiction has discretionary powers to permit deviation from the provisions of this code, provided that such proposal to deviate is first submitted for proper determination in order that health and safety requirements, as they pertain to plumbing, shall be observed. SUBSTANTIATION: Section 301.1.3 should be deleted as the provisions are already stated in Section 101.6 (Repairs and Alterations), and therefore redundant. For informational purposes only, Section 101.6 (Repairs and Alterations) is shown as follows: In existing buildings or premises in which plumbing installations are to be altered, repaired, or renovated, deviations from the provisions of this code are permitted, provided such deviations are found to be necessary and are first approved by the Authority Having Jurisdiction. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: Task group feels that even though the language is redundant it is necessary as not all jurisdictions adopt Chapter 1. Item #18 RECOMMENDATION: Revise text as follows: 302.0 Iron Pipe Size (IPS) Pipe Pipe, Tubing, and Fitting Sizes.

  • 10

    302.1 General. Unless otherwise specified, Iiron, steel, brass, and copper pipe shall be standard-weight iron pipe size (IPS) pipe expressed in nominal or standard sizes as referenced in Table 1401.1 for material standards. 316.0 Increasers and Reducers. 316.1 General. Where different sizes of pipes and fittings are to be connected, the proper size increasers or reducers or reducing fittings shall be used between the two sizes. Brass or cast-iron body cleanouts shall not be used as a reducer or adapter from cast-iron drainage pipe to iron pipe size (IPS) metallic pipe.

    TABLE 1208.5.7.2 SPECIFICATIONS FOR THREADING METALLIC PIPE

    [NFPA 54: TABLE 5.6.7.3] IRON NOMINAL OR STANDARD PIPE SIZE

    (inches)

    APPROXIMATE LENGTH OF THREADED PORTION (inches)

    APPROXIMATE NUMBER OF THREADS TO BE CUT

    (portions of table not shown remain unchanged) E 32.1 Metal. Metal gas pipe shall be standard-weight wrought iron or steel (galvanized or black), yellow brass containing not more than 75 percent copper, or internally tinned or treated copper of iron based on nominal or standard pipe size. Galvanizing shall not be considered protection against corrosion. (remaining text unchanged) E 36.6.4 Vent. Tanks with a capacity not larger than 660 gallons (2498 L) shall be equipped with an open vent not smaller than a 112 inch (40 mm) iron nominal or standard pipe size; tanks with a 500 gallon (1892 L) or less capacity shall have a vent of 11/4 inch (32 mm) iron nominal or standard pipe size. [NFPA 501A:4.4.6.4] SUBSTANTIATION: Last cycle, the technical committee decided to keep the term iron pipe size in the UPC based on the reason that the term is still used in the field. However, this assumption should be challenged as the term iron pipe size is no longer used in codes or standards as the term was replaced by the American Standards Association in March of 1927 with nominal or standard sizes for all piping, tubing, and fittings. The ASTM, ASME, AWWA, CISPI, and CSA material standards referenced in Table 1401.1 of the UPC indicate nominal or standard sizes for all piping, tubing, and fittings, and not iron pipe size. Furthermore, the term is no longer used within the industry as referenced in the United Association Instructor Training Program Course 251 which states: Definition for Pipe Size See Nominal Pipe Size, and does not state iron pipe size. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: There are still several manufacturers, specifications, and various other types of literature that specify IPS. Additionally, IPS material is still in service, and therefore such requirements should not be deleted from the code. Item #19 RECOMMENDATION: Add new text as follows: 310.9 Dead Ends. Dead ends shall be prohibited except where otherwise approved to extend a cleanout in accordance with Section 707.9. 206.0 Dead End. A drain pipe that measures 2 feet (610 mm) or more in length that is closed on one end.

  • 11

    SUBSTANTIATION: 1. Dead ends tend to collect solid wastes since they do not receive the discharge from fixtures resulting

    in potential backups in the drainage system. Even though Section 310.5 prohibits any installation from obstructing or retarding the flow of sewage in a drainage system, provisions should be added to clarify to the end user that the installation of dead ends is prohibited as well. An exception to the requirement, where approved by the AHJ, should be added where cleanouts for underfloor piping need to be extended above the finished floor or to the outside of a building in accordance with Section 707.9.

    2. The definition for dead end is based on similar language found in ASSE standards. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The proposed language would be very restrictive and prevent future expansion of a drainage system. Item #20 RECOMMENDATION: Revise text as follows: 312.6 Freezing Protection. No water, soil, or waste pipe shall be installed or permitted outside of a building, in attics or crawl spaces, or in an exterior wall unless, where necessary, adequate provision is made to protect such pipe from freezing. SUBSTANTIATION: The current text does not account for locations such as attics and crawl spaces that may be susceptible to freezing temperatures. Therefore, the revision is necessary to protect piping installed in such locations from freezing. TASK GROUP ACTION: Accept as Submitted Item #21 RECOMMENDATION: Revise text as follows: 312.12.1 Meter Boxes. Meter boxes shall be constructed in such a manner that rats rodents cannot enter are not capable of entering a building by following the service pipes from the box into the building. SUBSTANTIATION: 1. The term rats should be changed to rodents to be consistent with the title for Section 312.12

    (Rodentproofing). Furthermore, there are other types of vermin besides rats (ex: mice, snakes, insects, etc.) that should be prevented from entering a building through openings or penetrations.

    2. The other revisions being proposed are based on the IAPMO Manual of Style. TASK GROUP ACTION: Accept as Modified 312.12.1 Meter Boxes. Meter boxes shall be constructed in such a manner as to restrict that rodents or vermin from are not capable of entering a building by following the service pipes from the box into the building.

  • 12

    Item #22 RECOMMENDATION: Revise text as follows: 313.5 Piping, Fixtures, Appliances, and Appurtenances. Piping, fixtures, appliances, and appurtenances shall be adequately supported in accordance with this code, the manufacturers installation instructions, and in accordance with the Authority Having Jurisdiction. (remaining text unchanged) SUBSTANTIATION: Section 313.0 of the UPC only deals with the support of piping, and not fixtures, appliances, or appurtenances. Therefore, Section 313.5 (Piping, Fixtures, Appliances, and Appurtenances) should be revised accordingly. TASK GROUP ACTION: Accept as Submitted Item #23 RECOMMENDATION: Add new text as follows:

    TABLE 313.1 HANGERS AND SUPPORTS

    MATERIALS TYPES OF JOINTS HORIZONTAL VERTICAL PE-RT Cold Expansion, Insert and

    Compression 1 inch and smaller, 32 inches; 11/4 inches and larger, 4 feet

    Base and each floor; provide mid-story guides

    (portions of table not shown remain unchanged) SUBSTANTIATION: In the 2012 UPC, PE-RT tubing was added as an approved building and water distribution material. However, provisions were not added for the support of such tubing in Table 313.1. The proposed language is based on the recommendations of the Plastics Pipe Institute and manufacturers. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: There is no technical justification as to where or how the proposed horizontal spacing requirements were derived. Item #24 RECOMMENDATION: Revise text as follows:

    TABLE 313.1 HANGERS AND SUPPORTS

    MATERIALS TYPES OF JOINTS HORIZONTAL VERTICAL Lead Wiped or Burned Continuous support Not to exceed 4 feet 401.2 Lead. Sheet lead shall be not less than the following: For safe pans not less than 4 pounds per square foot (lb/ft2) (19 kg/m2) or 116 of an inch (1.6 mm) thick. (See Table 1401.1)

  • 13

    701.3 Lead. (See Table 1401.1) Sheet lead shall be not less than the following: (1) For safe pans not less than 4 pounds per square foot lb/ft2 (19 kg/m2) or 116 of an inch (1.6 mm) thick. (2) For flashings or vent terminals not less than 3 lb/ft2 (15 kg/m2) or 0.0472 of an inch (1.1989 mm) thick. (3) Lead bends and lead traps shall be not less than 18 of an inch (3.2 mm) wall thickness. (renumber remaining sections) 906.6 Lead. (See Table 1401.1) Sheet lead shall be not less than the following: (1) For safe pans not less than 4 pounds per square foot (lb/ft2) (19 kg/m2) or 116 of an inch (1.6 mm) thick. (2) For flashings or vent terminals - not less than 3 lb/ft2 (15 kg/m2). (3) Lead bends and lead traps shall be not less than 18 of an inch (3.2 mm) wall thickness. (renumber remaining sections) 1003.1 General Requirements. Each trap, except for traps within an interceptor or similar device shall be self-cleaning. Traps for bathtubs, showers, lavatories, sinks, laundry tubs, floor drains, urinals, drinking fountains, dental units, and similar fixtures shall be of standard design, weight and shall be of ABS, cast-brass, cast-iron, lead, PP, PVC, or other approved material. An exposed and readily accessible drawn-brass tubing trap, not less than 17 B & S Gauge (0.045 inch) (0.114 mm), shall be permitted to be used on fixtures discharging domestic sewage. Exception: Drawn-brass tubing traps shall not be used for urinals. Each trap shall have the manufacturers name stamped legibly in the metal of the trap, and each tubing trap shall have the gauge of the tubing in addition to the manufacturers name. A trap shall have a smooth and uniform interior waterway. SUBSTANTIATION: 1. Section 408.7 (Lining for Showers and Receptors) already provides sizing requirements for lead pans,

    and therefore Section 401.2 is redundant. For informational purposes only, Section 408.7 (7th paragraph) is being shown as follows: Shower lining materials shall comply with approved standards acceptable to the Authority Having Jurisdiction. Lead and copper subpans or linings shall be insulated from conducting substances other than their connecting drain by 15 pound (6.8 kg) asphalt felt or its equivalent, and no lead pan or liner shall be constructed of material weighing less than 4 lb/ft2 (19 kg/m2). Copper pans or liners shall be not less than No. 24 B & S Gauge (0.02 inches) (0.51 mm). Joints in lead pans or liners shall be burned. Joints in copper pans or liners shall be soldered or brazed. Plastic pans shall not be coated with asphalt-based materials.

    2. The only place within the UPC where safe pans are recognized is in Section 408.7 (Lining for Showers and Receptors) for built on-site shower receptors. Therefore, such provisions should not be located in Chapters 7 or 9.

    3. Table 701.1 does not recognize lead as an approved material to be used for drain, waste, and vent pipe. Therefore, provisions for hangers used for lead pipe, lead vent terminals, lead traps, etc. should be deleted.

    4. Provisions for lead flashings are not needed in Chapters 7 or 9 as such provisions are already addressed in Section 312.8 (Waterproofing of Openings). For informational purposes only, Section 312.8 is being shown as follows: Joints at the roof around pipes, ducts, or other appurtenances shall be made watertight by the use of lead, copper, galvanized iron, or other approved flashings or flashing material. Exterior wall openings shall be made watertight. Counterflashing shall not restrict the required internal cross-sectional area of the vent.

    TASK GROUP ACTION: Accept as Modified 1003.1 General Requirements. Each trap, except for traps within an interceptor or similar device shall be self-cleaning. Traps for bathtubs, showers, lavatories, sinks, laundry tubs, floor drains, urinals, drinking fountains, dental units, and similar fixtures shall be of standard design, weight and shall be of ABS, cast-brass, cast-iron, lead, PP, PVC, or other approved material. An exposed and readily accessible drawn-brass tubing trap, not less than 17 B & S Gauge (0.045 inch) (0.114 mm), shall be permitted to be used on fixtures discharging domestic sewage.

  • 14

    Exception: Drawn-brass tubing traps shall not be used for urinals. Each trap shall have the manufacturers name stamped legibly in the metal of the trap, and each tubing trap shall have the gauge of the tubing in addition to the manufacturers name. A trap shall have a smooth and uniform interior waterway. Item #25 RECOMMENDATION: Revise text as follows: 314.1 Trenches. Trenches deeper than the footing of a building or structure, and paralleling the same, shall be located not less than 45 degrees (0.79 rad) therefrom from the bottom exterior edge of the footing, or as approved in accordance with Section 301.0 of this code. SUBSTANTIATION: The current text is not clear, and is commonly misunderstood. The proposed text clarifies the intent of the section. The text referencing approval in accordance with Section 301.0 is not needed as an AHJ can always approve an alternate material or method of construction in accordance with Section 301.2 (Alternate Materials and Methods of Construction Equivalency). TASK GROUP ACTION: Accept as Submitted Item #26 RECOMMENDATION: Revise text as follows: 315.1 Unions. Approved unions shall be permitted to be used in drainage piping where accessibly located in the trap seal or between a fixture and its trap; in the vent system, except underground or in wet vents,; at a any point in the water supply system,; and in gas piping as permitted by Section 1211.5. SUBSTANTIATION: The section is commonly misunderstood due to its structure. In other words, where the text states used in drainage piping where accessibly located in the trap seal or between a fixture and its trap in the vent system, except underground or in wet vents should be restructured as the text is really indicating two different locations where unions are approved and not just one. This section as a whole indicates locations within four different systems (drainage piping, vent piping, water supply, and fuel gas) where unions are permitted. TASK GROUP ACTION: Accept as Submitted Item #27 RECOMMENDATION: Delete text without substitution: 315.2.1 Obstruction. No fitting or connection that offers abnormal obstruction to flow shall be used. The enlargement of a 3 inch (76 mm) closet bend or stub to 4 inches (102 mm) shall not be considered an obstruction. SUBSTANTIATION: The provisions of Section 315.2.1 are already stated in Section 310.5, and therefore redundant. For informational purposes only, Section 310.5 (Obstruction of Flow) is shown as follows: No fitting, fixture and

  • 15

    piping connection, appliance, device, or method of installation that obstructs or retards the flow of water, wastes, sewage, or air in the drainage or venting systems, in an amount exceeding the normal frictional resistance to flow, shall be used unless it is indicated as acceptable in this code or is approved in accordance with Section 301.1 of this code. The enlargement of a 3 inch (76 mm) closet bend or stub to 4 inches (102 mm) shall not be considered an obstruction. TASK GROUP ACTION: Accept as Submitted Item #28 RECOMMENDATION: Revise text as follows: 402.5 Setting. Fixtures shall be set level and in proper alignment with reference to adjacent walls. No water closet, lavatory, or bidet shall be set closer than 15 inches (381 mm) from its center to a side wall or obstruction nor closer than 30 inches (762 mm) center to center to a similar fixture. The clear space in front of a water closet, lavatory, or bidet shall be not less than 24 inches (610 mm). No urinal shall be set closer than 12 inches (305 mm) from its center to a side wall or partition nor closer than 24 inches (610 mm) center to center. Exception: The installation of paper dispensers or accessibility grab bars shall not be considered obstructions. SUBSTANTIATION: The UPC is silent on providing direction to an installer or an inspector for the proper setting of a lavatory. Provisions should be included for lavatories that are consistent with industry standards and practices. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The proposed requirements would restrict corner lavatories, and therefore is too restrictive. Item #29 RECOMMENDATION: Add new text as follows: 407.5 Footbaths and Shampoo Sinks. Hot water delivered to public footbaths or shampoo sinks shall be limited to a maximum temperature of 120F (49C) by a device that is listed in accordance with ASSE 1070 or CSA B125.3. The water heater thermostat shall not be considered a control for meeting this provision. SUBSTANTIATION: The UPC does not provide provisions for safeguarding the public from scalding where footbaths or shampoo sinks are used. TASK GROUP ACTION: Accept as Modified 407.5 Footbaths and Shampoo Sinks. Hot water delivered to public footbaths or shampoo sinks shall be limited to a maximum temperature of 120F (49C) by a device that is listed in accordance with ASSE 1070 or CSA B125.3. The water heater thermostat shall not be considered a control for meeting this provision.

  • 16

    Item #30 RECOMMENDATION: Revise text as follows: 408.4 Waste Outlet. Showers shall have a waste outlet and fixture tailpiece not less than 2 inches (50 mm) 11/2 inches (40 mm) in diameter. Fixture tailpieces shall be constructed from the materials specified in Section 701.1 for drainage piping. Strainers serving shower drains shall have a waterway at least equivalent to the area of the tailpiece.

    TABLE 702.1 DRAINAGE FIXTURE UNIT VALUES (DFU)

    PLUMBING APPLIANCES, APPURTENANCES, OR FIXTURES

    MINIMUM SIZE TRAP AND TRAP ARM7

    (inches) PRIVATE PUBLIC ASSEMBLY8

    Shower, single-head trap 2 11/2 2.0 2.0 2.0 Multi-head, each additional 2 11/2 1.0 1.0 1.0 (portions of table not shown remain unchanged) SUBSTANTIATION: 1. It is illogical for the UPC to permit a combination tub/shower to have a minimum 11/2 inch diameter

    tailpiece, while requiring a shower to have a minimum 2 inch diameter tailpiece. Both fixtures have showerheads that provide a maximum flow rate of 2.5 gpm at 80 psi in accordance with ASME A112.18.1/CSA B125.1. Both fixtures should have the same size tailpiece.

    2. With low flow fixtures, a 11/2 inch versus 2 inch diameter pipe permits better scouring within the drainage piping system, and therefore a reduction in the number of clogs that can occur.

    TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The reason that a 11/2 inch trap works for a tub/shower combo, and not a shower, is that a tub/shower combo generally has a overflow that prevents water from spilling over the top of the fixture. Furthermore, it is extremely difficult to clean hair out of a 1 inch shower trap. Item #31 RECOMMENDATION: Revise text as follows: 408.7.1 Tests for Shower Receptors. Shower receptors shall be tested for watertightness by filling with water to the level of the rough threshold. Where a threshold does not exist, a temporary threshold of not less than 2 inches (51 mm) in depth shall be constructed in accordance with the Authority Having Jurisdiction. The test plug shall be so placed that both upper and under sides of the subpan shall be subjected to the test at the point where it is clamped to the drain. SUBSTANTIATION: Since the 2012 Uniform Plumbing Code no longer requires a threshold to be installed for showers (refer to Section 408.5), provisions are necessary for an installer or inspector to be able to test the watertightness of a shower receptor with a liner when a permanent threshold is not present. The construction of such a threshold should be left up to the approval of the AHJ. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: There is no practical method to consistently implement the proposed language in the field. The proposed language could create inconsistency and confusion within the enforcement community.

  • 17

    Item #32 RECOMMENDATION: Revise text as follows: 417.2 Deck Mounted Bath/Shower Valves. Deck mounted bath/shower transfer valves with integral backflow protection shall comply be listed in accordance with ASME A112.18.7 ASME A112.18.1/CSA B125.1. This shall include hand held showers and other bathing appliances mounted on the deck of bathtubs or other bathing appliances that incorporate a hose or pull out feature. SUBSTANTIATION: ASME A112.18.7 is no longer published by ASME, and has been replaced with ASME A112.18.1/CSA B125.1 beginning February 2012. TASK GROUP ACTION: Accept as Submitted Item #33 RECOMMENDATION: Revise text as follows: 417.5 Separate Controls for Hot and Cold Water. Where two separate handles control the hot and cold water, the left-hand control of the faucet where facing the fixture fitting outlet shall control the hot water. Faucets and diverters shall be connected to the water distribution system so that hot water corresponds to the left side of the fixture fittings.

    Single-handle mixing valves used in showers and tub-shower combinations shall have the flow of hot water correspond to the markings on the fixture fitting. 208.0 Fixture Fitting. A fitting used to control the volume of water, the flow direction of water, or both to a fixture. SUBSTANTIATION: 1. The last sentence of Section 417.5 has been misinterpreted by various jurisdictions to prohibit single

    handle kitchen or lavatory faucets from being used that are not marked hot and cold on the actual faucet. This was not the intent of the original proponent (PMI) that submitted this code language. The original intent of the proponent was to protect an individual in a shower or combination tub/shower from scalding and thermal shock.

    2. The term mixing valve is only used in the UPC in regards to pressure balance, thermostatic, or combination pressure balance/thermostatic mixing valves used in showers and tub-shower combinations. The term is not applicable to kitchen or lavatory faucets.

    3. The applicable standard used throughout the industry for plumbing supply fittings (ASME A112.18.1) only requires temperature markings to be indicated on mixing valves used in showers and tub-shower combinations. No where within the standard does it indicate that a kitchen or lavatory faucet needs to have temperature markings. For informational purposes only, Section 6.2 of ASME A112.18.1 is shown as follows: Section 6.2 (Temperature identification): Single-handle, single-control, and automatic compensating mixing bath and shower valves shall have identifiable temperature control settings in which the setting are indicated by words (cold, warm, hot, etc.) by numbers, or graphically.

    4. The term fixture fitting is used not only in Section 417.5, but Sections 402.10, 417.1, 417.4, 421.0, 603.5.20, 608.1, L 402.1, and L 801.0 without being defined. The proposed definition assists the end user in applying and enforcing this term. The revisions being proposed throughout Section 417.5 to change fitting to fixture fitting is consistent with the intent of the section and the new definition.

    TASK GROUP ACTION: Accept as Submitted

  • 18

    Item #34 RECOMMENDATION: Revise text as follows: 414.3 Drainage Connection. Domestic dishwashing machines shall discharge indirectly through an air gap fitting in accordance with Section 807.4 into a waste receptor, a wye branch fitting on the tailpiece of a kitchen sink, or dishwasher connection of a food waste grinder disposer. Commercial dishwashing machines shall discharge indirectly through an air gap or direct connection in accordance with Section 704.3 with floor drain protection. 419.0 Food Waste Disposal Units Disposers. 419.1 Application. Food waste disposal units disposers shall comply with the applicable standards referenced in Table 1401.1. 419.2 Drainage Connection. Approved wye or other directional-type branch fittings shall be installed in continuous wastes connecting or receiving the discharge from a food waste disposal unit disposer. No dishwasher drain shall be connected to a sink tailpiece, continuous waste, or trap on the discharge side of a food waste disposal unit disposer. 419.3 Water Supply. A cold water supply shall be provided for food waste disposal unit disposers. Such connection to the water supply shall be protected by an air gap or backflow prevention device in accordance with Section 603.2.

    TABLE 702.1 DRAINAGE FIXTURE UNIT VALUES (DFU)

    PLUMBING APPLIANCES, APPURTENANCES, OR FIXTURES

    MINIMUM SIZE TRAP AND TRAP ARM7

    (inches) PRIVATE PUBLIC ASSEMBLY8

    Food Waste Grinder Disposer, commercial 2 - 3.0 3.0 Kitchen, domestic2 (with or without food waste grinder disposer, dishwasher, or both)

    11/2 2.0 2.0 -

    (portions of table not shown remain unchanged) 714.4 Commercial Food Waste Grinder Disposer. The Authority Having Jurisdiction shall review before approval, the installation of a commercial food waste grinder disposer connecting to a private sewage disposal system. 1001.1 Where Required. Each plumbing fixture, shall be separately trapped by an approved type of liquid seal trap. This section shall not apply to fixtures with integral traps. Not more than one trap shall be permitted on a trap arm. Food waste disposal units disposers installed with a set of restaurant, commercial, or industrial sinks shall be connected to a separate trap. Each domestic clothes washer and each laundry tub shall be connected to a separate and independent trap, except that a trap serving a laundry tub shall be permitted to also receive the waste from a clothes washer set adjacent thereto. The vertical distance between a fixture outlet and the trap weir shall be as short as practicable, but in no case shall the tailpiece from a fixture exceed 24 inches (610 mm) in length. One trap shall be permitted to serve a set of not more than three single compartment sinks or laundry tubs of the same depth or three lavatories immediately adjacent to each other and in the same room where the waste outlets are not more than 30 inches (762 mm) apart and the trap is centrally located where three compartments are installed. 1014.1.3 Food Waste Disposal Units Disposers and Dishwashers. Unless specifically required or permitted by the Authority Having Jurisdiction, no food waste disposal unit disposer or dishwasher shall be connected to or discharge into a grease interceptor. Commercial food waste disposers shall be permitted to discharge directly into the buildings drainage system.

    TABLE H 2.1

    CAPACITY OF SEPTIC TANKS1, 2, 3, 4 (portions of table not shown remain unchanged)

  • 19

    Notes: Footnotes 1 3 (remaining text unchanged) 4 Septic tank sizes in this table include sludge storage capacity and the connection of domestic food waste disposal units

    disposers without further volume increase. SUBSTANTIATION: The correct term used within the plumbing industry is food waste disposer, and not food waste grinder or food waste disposal unit. This change also correlates the UPC with the terminology used in the applicable referenced standards listed in Table 1401.1 (AHAM FWD-1, ASSE 1008, and IAPMO PS 113). TASK GROUP ACTION: Accept as Submitted Item #35 RECOMMENDATION: Revise text as follows 403.5 420.3 Pre-Rinse Spray Valve. Commercial food service pre-rinse spray valves shall have a maximum flow rate of 1.6 gallons per minute (gpm) at 60 pounds-force per square inch (psi) (0.10 L/s at 414 kPa) in accordance with ASME A112.18.1/CSA B125.1 and shall be equipped with an integral automatic shutoff. (renumber remaining sections) SUBSTANTIATION: Provisions for pre-rinse spray valves should be located under Section 420.0 (Sinks) for ease of application and enforcement. TASK GROUP ACTION: Accept as Submitted Item #36 RECOMMENDATION: Revise text as follows 422.4.1 Access to Toilet Facilities. In multi-story buildings, accessibility to the required toilet facilities shall not exceed one vertical story. Access to the required toilet facilities for customers shall not pass through areas designated as for employee use only such as kitchens, food preparation areas, storage rooms, closets, or similar spaces. A toilet facility shall not open into a room or space used for food preparation. Toilet facilities accessible only to private offices shall not be counted to determine compliance with this section. SUBSTANTIATION: The revision to Section 422.4.1 is necessary in order to keep rooms or areas used for food preparation in a sanitary condition. TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The proposed language is too restrictive and is considered an architectural issue that is outside the scope of the plumbing code.

  • 20

    Item #37 RECOMMENDATION: Revise text as follows

    TABLE 422.1 MINIMUM PLUMBING FACILITIES1 (continued)

    TYPE OF OCCUPANCY

    2

    WATER CLOSETS (FIXTURES PER

    PERSON)3

    URINALS (FIXTURES PER

    PERSON)4

    LAVATORIES (FIXTURES PER

    PERSON)5

    BATHTUBS OR SHOWERS

    (FIXTURES PER PERSON)

    DRINKING FOUNTAINS /FACILITIES (FIXTURES

    PER PERSON) OTHER

    (portions of table not shown remain unchanged) Notes: (Footnotes 1 - 3 remain unchanged) 4 For each urinal added in excess of the minimum required, one water closet shall be permitted to be deducted. The number of

    water closets shall not be reduced to less than two-thirds of the minimum requirement. 5 Group lavatories that are 24 lineal inches (610 mm) of wash sink or 18 inches (457 mm) of a circular basin, where provided

    with water outlets for such space, shall be considered equivalent to one lavatory. SUBSTANTIATION: 1. The provisions for the substitution of urinals for water closets was in the 2009 UPC as footnote #5 of

    Table 4-1, and should have been brought forward in the 2012 UPC with the revisions made to Table 422.1. It is common industry practice to permit a certain percentage of water closets to be substituted with urinals in male toilet facilities to conserve space.

    2. The provisions for group lavatories was in the 2009 UPC as footnote #8 of Table 4-1, and should have been brought forward in the 2012 UPC with the revisions made to Table 422.1. This design option is common in outdoor assembly, factory, and industry occupancies, but is not limited to such occupancies.

    TASK GROUP ACTION: Accept as Submitted Item #38 RECOMMENDATION: Revise text as follows 507.4 Drainage Pan. Where a water heater is located in an attic, in or on an attic-ceiling assembly, floor-ceiling assembly, or floor-subfloor assembly where damage results from a leaking water heater, a watertight pan of corrosion-resistant materials shall be installed beneath the water heater with not less than 34 of an inch (20 mm) diameter drain to an approved location. Such pan shall be not less than 11/2 inches (38 mm) in depth and of a size and shape in accordance with the manufacturers installation instructions. SUBSTANTIATION: 1. The current language does not clearly address installations on an attic-ceiling assembly, floor-ceiling

    assembly, or floor-subfloor assembly which is the intent of this section of code, and has caused confusion within the industry in regards to the application and enforcement of this section.

    2. The depth of the pan is important for ensuring that enough space is provided for the drain connection fitting generally located on the side of the pan.

    TASK GROUP ACTION: Accept as Modified 507.4 Drainage Pan. Where a water heater is located in an attic, in or on an attic-ceiling assembly, floor-ceiling assembly, or floor-subfloor assembly where damage results from a leaking water heater, a watertight pan of corrosion-resistant materials shall be installed beneath the water heater with not less than 34 of an inch (20 mm) diameter drain to an

  • 21

    approved location. Such pan shall be not less than 11/2 inches (38 mm) in depth and of a size and shape in accordance with the manufacturers installation instructions. Item #39 RECOMMENDATION: Revise text as follows 507.5 Relief Valve Discharge. Discharge from a relief valve into a water heater pan shall be prohibited. Relief valves shall be discharged in accordance with Section 608.5. SUBSTANTIATION: The additional language is needed to assist the end user in locating the provisions in Section 608.5 that address the proper discharge of a relief valve drain pipe. TASK GROUP ACTION: Accept as Submitted Item #40 RECOMMENDATION: Delete text without substitution: 511.0 Direct-Vent Appliances. 511.1 General. Listed direct-vent appliances shall be considered properly vented where installed in accordance with the terms of its listing, the manufacturers instructions, and Section 509.8.2. [NFPA 54:12.3.5] SUBSTANTIATION: The provisions of Sections 511.0 & 511.1 are already stated in Section 509.2.4 (Direct-Vent Appliances), and therefore redundant. For informational purposes only, Section 509.2.4 (Direct-Vent Appliances) is shown as follows: Listed direct-vent appliances shall be installed in accordance with the manufacturers installation instructions and Section 509.8.2. [NFPA 54:12.3.5] TASK GROUP ACTION: Accept as Submitted Item #41 RECOMMENDATION: Revise text as follows 603.2 Approval of Devices or Assemblies. Before a device or an assembly is installed for the prevention of backflow, it shall have first been approved by the Authority Having Jurisdiction. Devices or assemblies shall be tested in accordance with recognized standards or other standards acceptable to the Authority Having Jurisdiction. Backflow prevention devices and assemblies shall comply with Table 603.2, except for specific applications and provisions as stated in Section 603.5.1 through Section 603.5.21.

    Devices or assemblies installed in a potable water supply system for protection against backflow shall be maintained in good working condition by the person or persons having control of such devices or assemblies. Such devices or assemblies shall be tested at the time of installation, repair, or relocation and not less than on an annual schedule thereafter, or more often where required by the Authority Having Jurisdiction. Where found to be defective or inoperative, the device or assembly shall be repaired or replaced. No device or assembly shall be removed from use or relocated or other device or assembly substituted, without the approval of the Authority Having Jurisdiction.

    Testing or maintenance shall be performed by a certified backflow assembly tester or repairer in accordance with ASSE Series 5000 or otherwise approved by the Authority Having Jurisdiction.

  • 22

    SUBSTANTIATION: ASSE Series 5000 provides provisions for both testing and maintenance of backflow devices, and should be addressed within the UPC. Furthermore, ASSE Series 5000 not only addresses certification requirements for testers, but repairers as well. This revision will provide clarity that both testers and repairers that are certified to ASSE Series 5000 are permitted to test backflow devices and assemblies in accordance with this code. TASK GROUP ACTION: Accept as Submitted Item #42 RECOMMENDATION: Revise text as follows 603.4.9 Prohibited Locations. Backflow prevention devices with atmospheric vents or ports shall not be installed in pits, underground, or submerged locations. 603.5.13 Prohibited Location. Backflow preventers shall not be located in an area containing fumes that are toxic, poisonous, or corrosive. SUBSTANTIATION: Section 603.5.13 should be combined with Section 603.4.9 so that all requirements pertaining to prohibited locations for backflow prevention devices are located in one section of code for ease of use. TASK GROUP ACTION: Accept as Submitted Item #43 RECOMMENDATION: Delete text without substitution:

    TABLE 604.1 MATERIALS FOR BUILDING SUPPLY AND WATER DISTRIBUTION PIPING AND FITTINGS

    MATERIAL BUILDING SUPPLY PIPE AND FITTINGS WATER DISTRIBUTION PIPE

    AND FITTINGS REFERENCED

    STANDARD(S) PIPE REFERENCED

    STANDARD(S) FITTINGS Asbestos-Cement X* ASTM C 296 (portions of table not shown remain unchanged) 605.1 Asbestos-Cement Pipe and Joints. Joining methods for asbestos-cement pipe and fittings shall be installed in accordance with the manufacturers installation instructions and shall comply with Section 605.1.1. 605.1.1 Mechanical Joints. Mechanical joints shall be of the same composition as the pipe and sealed with an approved elastomeric gasket or joined by a listed compression type coupling. Elastomeric gaskets shall comply with ASTM D 1869. The coupling grooves, pipe ends, and elastomeric gaskets shall be cleaned. Elastomeric gaskets shall be positioned in the grooves. Lubricant recommended for potable water application by the pipe manufacturer shall be applied to the machined end of the pipe. Lubricant shall not be applied to the elastomeric gasket or groove, unless specifically recommended by the manufacturer. (renumber remaining text accordingly)

    TABLE 701.1 MATERIALS FOR DRAIN, WASTE, VENT PIPE AND FITTINGS

    MATERIAL UNDERGROUND DRAIN,

    WASTE, VENT PIPE AND FITTINGS

    ABOVEGROUND DRAIN, WASTE, VENT PIPE

    AND FITTINGS

    BUILDING SEWER PIPE AND FITTINGS

    REFERENCED STANDARD(S) PIPE

    REFERENCED STANDARD(S)

    FITTINGS Asbestos-Cement X ASTM C 14*, ASTM C 428*

  • 23

    (portions of table not shown remain unchanged) 705.2 Asbestos-Cement Pipe and Joints. Joining methods for asbestos-cement pipe and fittings shall be installed in accordance with the manufacturers installation instructions and shall comply with Section 705.2.1. 705.2.1 Mechanical Joints. Mechanical joints shall be of the same composition as the pipe and sealed with an approved elastomeric gasket or joined by a listed compression type coupling. Elastomeric gaskets shall comply with ASTM D 1869. The coupling grooves, pipe ends, and elastomeric gaskets shall be cleaned. Elastomeric gaskets shall be positioned in the grooves. Lubricant recommended by the manufacturer shall be applied to the machined end of the pipe. Lubricant shall not be applied to the elastomeric gasket or groove, unless specifically recommended by the manufacturer.

    TABLE 1102.5 MATERIALS FOR SUBSOIL DRAIN PIPE AND FITTINGS MATERIAL REFERENCED STANDARD(S)

    Asbestos Cement ASTM C 444, ASTM C 508 ASTM C 966 (portions of table not shown remain unchanged) SUBSTANTIATION: Asbestos-cement piping is no longer manufactured in North America. Furthermore, the potential health issues associated with this material makes it unsafe for most water supply and drainage applications. This proposed change recommends that asbestos-cement piping be removed from the UPC. If for some reason an individual wanted to use this piping material they could always do so in accordance with Section 301.2 (Alternate Materials and Methods of Construction Equivalency). TASK GROUP ACTION: Accept as Submitted Item #44 RECOMMENDATION: Revise text as follows: 604.4 Flexible Copper Connectors. Listed flexible copper water connectors shall be installed in readily accessible locations, unless otherwise listed. SUBSTANTIATION: Whether a flexible water connector is copper or any other type of material (unless otherwise listed) it should be installed in a readily accessible location for maintenance purposes. TASK GROUP ACTION: Accept as Submitted Item #45 RECOMMENDATION: Revise text as follows: 604.11 Lead Content. Water pipe and fittings with a lead content which exceeds 8 percent shall be prohibited in piping systems used to convey potable water. The maximum allowable lead content in pipes and pipe fittings, plumbing fittings, and fixtures intended to convey or dispense water for human consumption shall be a weighted average of 0.25 percent with respect to the wetted surfaces of pipes and pipe fittings, plumbing fittings, and fixtures.

  • 24

    SUBSTANTIATION: This revision brings the UPC in accordance with the latest revisions made to the Safe Water Drinking Act that go into effect on January 4, 2014. TASK GROUP ACTION: Accept as Submitted Item #46 RECOMMENDATION: Revise text as follows 606.0 Valves. 606.1 General. Valves up to and including 2 inches (50 mm) in size shall be brass or other approved material. Sizes exceeding 2 inches (50 mm) shall be permitted to have cast-iron or brass bodies. Each gate or ball valve shall be a fullway type with working parts of non-corrosive material. Valves carrying water used in potable water systems intended to supply drinking water shall be in accordance with the requirements of NSF 61 as referenced in Table 1401.1. 606.6 Accessible. Required fullway or shutoff or control valves shall be accessible. 606.2 Fullway Valves. A fullway valve controlling outlets shall be installed on the discharge side of each water meter and on each unmetered water supply. Water piping supplying more than one building on one premises shall be equipped with a separate fullway valve to each building, so arranged that the water supply can be turned on or off to an individual or separate building provided; however, that supply piping to a single-family residence and building accessory thereto shall be permitted to be controlled on one valve. Such shutoff valves shall be accessible. A fullway valve shall be installed on the discharge piping from water supply tanks at or near the tank. A fullway valve shall be installed on the cold water supply pipe to each water heater at or near the water heater. 606.4 Multiple Openings. Valves used to control two or more openings shall be fullway gate valves, ball valves, or other approved valves designed and approved for the service intended. 606.5 Control 606.3 Shutoff Valves. A control shutoff valve shall be installed immediately ahead of each water-supplied appliance, and immediately ahead of each slip joint, or appliance supply; 606.7 Multiple Fixtures. A single control valve shall be installed on a water supply line ahead of an automatic metering valve that supplies to each a fixture (excluding bathtubs or showers) or battery of fixtures; and Parallel water distribution systems shall provide a control valve either immediately ahead of each fixture being supplied or installed at the manifold of a parallel water distribution system, and shall be identified with the fixture being supplied. 606.3 Multidwelling Units. In multidwelling units, one or more shutoff valves shall be provided in each dwelling unit so that the water supply to a plumbing fixture or group of fixtures in that dwelling unit can be shut off without stopping water supply to fixtures in other dwelling units. These valves shall be accessible in the dwelling unit that they control. SUBSTANTIATION: 1. This code proposal attempts to reorganize this section of code into a more logical order for ease of

    application and enforcement, and to clarify the appropriate type of valve to be used based on the application to ensure proper installation and enforcement of the code. A fullway valve (gate or ball valve) is designed to be used where obstruction of flow is not desired such as the water service to the building. A shutoff valve, and not a control valve, should be used for isolating appliances, fixtures, etc. for service or repair.

    2. Former Section 606.6 (Accessible) should be combined with Section 606.1 (General) as accessible requirements apply to both fullway and shutoff valves.

    3. In Section 606.2 (Fullway Valves), the text Such shutoff valves shall be accessible should be deleted as this section of code deals with fullway valves, and not shutoff valves.

    4. In former Section 606.4 (Multiple Openings), it is not necessary to state fullway gate valves, ball valves as the second sentence of Section 606.1 (General) already states Each gate or ball valve shall be a fullway type. Therefore, such text is redundant.

    5. The text ahead of an automatic metering valve should be deleted because it should not matter whether or not an automatic metering valve is installed as a shutoff valve should be installed on the supply to each fixture (except tubs and showers) or battery of fixtures in case of a repair or a replacement. Tubs and showers are excluded from the shutoff valve requirements, unless installed at

  • 25

    the manifold of a parallel water distribution system, as it would be quite difficult to make such valves accessible at the fixtures.

    6. Former Section 606.3 (Multidwelling Units) should be combined with new Section 606.3 (Shutoff Valves) since this section applies to the installation of shutoff valves in all types of occupancies including multidwelling units.

    TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: Control valves should be called supply stops, and not shutoff valves in accordance with ASME A112.18.1. Proposed revisions to Section 606.3 would also remove language that is necessary for the installation of valves. Item #47 RECOMMENDATION: Revise text as follows 607.0 Gravity Potable Water Supply Tanks. 607.1 General. Potable water supply tanks shall be installed in accordance with the manufacturers installation instructions, and supported in accordance with the building code. 607.2 Potable Water Tanks. Potable water supply tanks, interior tank coatings, or tank liners intended to supply drinking water shall be in accordance with NSF 61. 607.1 General 607.3 Venting. Gravity tTanks used for potable water shall be tightly covered, and vented in accordance with the manufacturers installation instructions. Such vent shall be screened with a corrosion-resistant material of not less than number 24 mesh. 607.4 Overflow. Tanks shall have not less than a 16 square inch (0.01 m2) overflow that is screened with copper screen a corrosion-resistant material of not less than number 24 mesh. having not less than 14 nor exceeding 18 openings per linear inch (25.4 mm) 607.5 Valves. Pressurized tanks shall be provided with a listed pressure-relief valve installed in accordance with the manufacturers installation instructions. The relief valve shall be discharged in accordance with Section 608.5. Where a potable water supply tank is located above the fixtures, appliances, or system components it serves it shall be equipped with an approved vacuum relief valve. SUBSTANTIATION: 1. Section 607.0 has been reorganized in a more logical order for ease of application and enforcement. 2. This section currently addresses gravity supply tanks, but is silent on those tanks that utilize a pump.

    Therefore, the terminology within this section of code should be revised accordingly to address both types of tanks.

    3. Currently the UPC lacks direction to the end user on how to install gravity supply tanks. Furthermore, the building code should be referenced for the support of a water tank since the full weight of tank must be considered when calculating dead loads when designing a structure.

    4. The first part of former Section 607.1 (General) has been relocated to new Section 607.3 (Cover). It is important for a tank to be vented to prevent pressures from developing in the tank as a result of water being pumped into or withdrawn from the tank. The vent of a tank should be screened to prevent the entrance of debris and vermin. The mesh size is based on Section E 62.0 (Storage Tanks) that addresses storage tanks used in recreational vehicle parks.

    5. New Section 607.4 (Overflow) should be revised to account for other types of approved screening material besides copper.

    6. Since pressurized tanks are connected to pumping equipment, it is possible that the pressure rating of the tank could be exceeded. Therefore, to protect the tank from possible rupture or failure an approved pressure-relief valve should be installed.

    7. Where a tank is located at an elevation above the system components, a vacuum relief valve is necessary to prevent atmospheric pressure from damaging the tank.

  • 26

    TASK GROUP ACTION: Accept as Submitted Item #48 RECOMMENDATION: Revise text as follows 608.3 Expansion Tanks, Combination Pressure, and Temperature Relief Valves. A water system provided with a check valve, backflow preventer, or other normally closed device that prevents dissipation of building pressure back into the water main, regardless of the type of water heater that is installed, shall be provided with an approved, listed, and adequately sized expansion tank or other approved device having a similar function to control thermal expansion. Such expansion tank or other approved device shall be installed on the building side of the check valve, backflow preventer, or other device and shall be sized and installed in accordance with the manufacturers installation instructions.

    A water system containing storage water heating equipment shall be provided with an approved, listed, adequately sized combination pressure and temperature relief valve, except for listed nonstorage instantaneous heaters having an inside diameter of not more than 3 inches (80 mm). Each such approved combination temperature and pressure relief valve shall be installed on the water-heating device in an approved location based on its listing requirements and the manufacturers installation instructions. Each such combination temperature and pressure relief valve shall be provided with a drain in accordance with Section 608.5. SUBSTANTIATION: There is a misunderstanding throughout the industry that if a tankless water heater is installed, an expansion tank is not necessary; this is not true. The above revision clarifies that regardless the type of water heater that is installed thermal expansion can still occur in the cold water supply line. Therefore, an approved expansion tank or other approved device needs to be installed. TASK GROUP ACTION: Accept as Modified 608.3 Expansion Tanks, Combination Pressure, and Temperature and Pressure Relief Valves. A water system provided with a check valve, backflow preventer, or other normally closed device that prevents dissipation of building pressure back into the water main, regardless of the type of water heater that is installed independent of the type of water heater used, shall be provided with an approved, listed, and adequately sized expansion tank or other approved device having a similar function to control thermal expansion. Such expansion tank or other approved device shall be installed on the building side of the check valve, backflow preventer, or other device and shall be sized and installed in accordance with the manufacturers installation instructions.

    A water system containing storage water heating equipment shall be provided with an approved, listed, adequately sized combination pressure and temperature relief valve, except for listed nonstorage instantaneous heaters having an inside diameter of not more than 3 inches (80 mm). Each such approved combination temperature and pressure relief valve shall be installed on the water-heating device in an approved location based on its listing requirements and the manufacturers installation instructions. Each such combination temperature and pressure relief valve shall be provided with a drain in accordance with Section 608.5. Item #49 RECOMMENDATION: Revise text as follows: 613.0 610.4 Parallel Distribution Systems. Systems within the range of Table 610.4 shall be permitted to be sized from that table or by the method in accordance with Section 610.5. Listed parallel water distribution systems shall be installed in accordance with their listing, but at no time shall a portion of the system exceed the maximum velocities allowed by the code.

  • 27

    613.1 General. Parallel distribution systems for plastic tubing shall be listed and installed in accordance with the manufacturers installation instructions. Manifolds shall be accessible where incorporating removable tubing connections or valves. 613.2 Valves. Individual fixture shutoff valves shall be installed in accordance with Section 606.5. 613.3 Installation. Tubing shall be not less than 12 inches (305 mm) vertically or 6 inches (152 mm) horizontally from sources of high heat unless protected by insulation or other approved method. Tubing shall be installed to permit expansion and contraction. Water distribution piping shall be permitted to be bundled together provided hot and cold water lines are separated by insulation and permit movement. 613.4 Sizing. Hot and cold water manifolds shall be sized in accordance with Table 613.4. Individual water distribution piping shall be sized in accordance with Table 613.4(1).

    TABLE 613.4 MANIFOLD SIZING

    MAXIMUM DEMAND (gallons per minute) INTERNAL DIAMETER

    (inches) VELOCITY at 4 feet per second VELOCITY at 8 feet per second

    1/2 2 5 6 11 1 10 20

    11/4 15 31 11/2 22 44 2 27 54

    For SI units: 1 inch = 25 mm, 1 gallon per minute = 0.06 L/s, 1 foot per second = 0.3048 m/s

    TABLE 613.4(1)

    MINIMUM SIZES OF INDIVIDUAL WATER DISTRIBUTION PIPING FOR PARALLEL DISTRIBUTION FIXTURE MINIMUM PIPE SIZE (inches)

    Bathtub or Combination Bath/Shower 1/2 Bidet 1/2 Clothes Washer 1/2 Lavatory 1/2 Sinks

    Kitchen, domestic 1/2 Laundry 1/2 Service or Mop Basin 1/2

    Shower, per head 1/2 Urinal, 1.0 GPF Flushometer Valve 3/4 Urinal, Flush Tank 1/2 Water Closet, 1.6 GPF Gravity Tank 1/2 Water Closet, 1.6 GPF Flushometer Tank 1/2 Water Closet, 1.6 GPF Flushometer Valve 3/4 For SI units: 1 inch = 25 mm SUBSTANTIATION: 1. During the 2012 UPC Code Cycle, the TC rejected a similar proposal as they felt such provisions

    could eliminate the use of copper systems due to the valve requirements. To address the issues of the TC, the proposed language only pertains to plastic tubing and references existing valve requirements located in Section 606.5. Therefore, there should be no impact on copper systems.

    2. The bottom line is that the UPC provides very little in the way of installation and sizing requirements for parallel water distribution systems. For one, the UPC does not address the installation of water distribution piping where exposed to sources of high heat, such as recessed light fixtures, flue gas vents, or heating appliances. Keeping tubing a minimum of 12 inches vertically or 6 inches horizontally away from sources of high heat is common practice when installing plastic tubing. Additionally, the UPC currently permits such systems to be sized in accordance with Table 610.4 which is incorrect as such systems are sized based on maximum demand measured in gallons per

  • 28

    minute, and not fixture units. The values provided in Table 613.4 do not conflict with the maximum velocities outlined in Section 610.12, and are based on industry standards.

    TASK GROUP ACTION: Forward to Technical Committee TASK GROUP STATEMENT: The velocity column for 4 feet per second in Table 613.4 conflicts with Section 610.12.2 where 5 feet per second is indicated for hot water. Additionally, the term high heat in Section 613.3 needs to be defined. Item #50 RECOMMENDATION: Revise text as follows 703.0 Size of Drainage Piping. 703.1 Minimum Size. The minimum sizes of vertical, horizontal, or both drainage piping shall be determined from the total of fixture units connected thereto, and additionally, in the case of vertical drainage pipes, in accordance with their length. 703.2 Maximum Number of Fixture Units. Table 703.2 shows the maximum number of fixture units allowed on a vertical or horizontal drainage pipe, building drain, or building sewer of a given size; the maximum number of fixture units allowed on a branch interval of a given size; and the maximum length (in feet and (meters) of a vertical drainage pipe of a given size. Where a multistory or engineered system design is present, a drainage system shall be permitted to be sized in accordance with Section 704.0. A vent system shall be permitted to be sized in accordance with Section 905.0. 703.3 Sizing per Appendix C. For alternate method of sizing drainage piping, see Appendix C. C 5.0 704.0 Alternate Method for Drainage System Sizing. 704.1 General. Drainage piping shall be sized in accordance with Section 704.2 and Section 704.3. C 5.2 Drainage Fixture Units. Drainage fixture unit values shall be sized in accordance with Table 702.1 and Section 702.0. C 5.3 704.2 Size of Building Drain and Building Sewer. The maximum number of drainage fixture units allowed on the building drain or building sewer of a given size shall be in accordance with Table C 5.3 704.2. The size of a building drain or building sewer serving a water closet shall be not less than 3 inches (80 mm).

    TABLE C 5.3 704.2 BUILDING DRAINS AND BUILDING SEWERS1

    MAXIMUM NUMBER OF DRAINAGE FIXTURE UNITS FOR SANITARY BUILDING DRAINS AND RUNOUTS FROM STACKS

    SLOPE (inches per foot) DIAMETER OF PIPE

    (inches) 1/16 1/8 1/2

    2 - - 21 26 21/2 - - 24 31 3 - 20 422 502 4 - 180 216 250 5 - 390 480 575 6 - 700 840 1000 8 1400 1600 1920 2300 10 2500 2900 3500 4200 12 2900 4600 5600 6700 15 7000 8300 10 000 12 000

    For SI units: 1 inch = 25 mm, 1 inch per foot = 83.3 mm/m Notes: 1 On-site sewers that serve more than one building shall be permitted to be sized according to the current standards and specifications of the

    administrative authority for public sewers. 2 A maximum of two water closets or two bathroom groups, except in single-family dwellings, where a maximum of three water closets or

    three bathroom groups shall be permitted to be installed.

  • 29

    C 5.4 704.3 Size of Horizontal Branch or Vertical Stack. The maximum number of drainage fixture units allowed on a horizontal branch or vertical soil or waste stack of a given size shall be in accordance with Table C 5.4 704.3. Stacks shall be sized based on the total accumulated connected load at each story or branch interval. C 5.4.1 704.3.1 Horizontal Stack Offsets. Horizontal stack offsets shall be sized in accordance with Table C 5.3 704.2 as required for building drains. C 5.4.2 704.3.2 Vertical Stack Offsets. Vertical stack offsets shall be sized in accordance with Table C 5.4 704.3 as required for stacks.

    TABLE C 5.4 704.3 HORIZONTAL FIXTURE BRANCHES AND STACKS

    MAXIMUM NUMBER OF DRAINAGE FIXTURE UNITS STACKS WITH MORE THAN THREE BRANCH INTERVALS

    DIAMETER OF PIPE (inches)

    HORIZONTAL FIXTURE BRANCH1

    ONE STACK OF THREE OR FEWER BRANCH

    INTERVALS TOTAL FOR STACK TOTAL AT ONE BRANCH

    INTERVAL 11/2 3 4 8 2 2 6 10 24 6

    21/2 12 20 42 9 3 202 482 722 202 4 160 240 500 90 5 360 540 1100 200 6 620 960 1900 350 8 1400 2200 3600 600 10 2500 3800 5600 1000 12 3900 6000 8400 1500 15 7000 6000 8400 1500

    For SI units: 1 inch = 25 mm Notes: 1 Does not include branches of the building drain. 2 A maximum of two water closets or bathroom groups within each branch interval or more than six water closets or bathroom groups on the

    stack. C 5.5 704.4 Horizontal Stack Offset and Horizontal Branch Connections. Horizontal branch connections shall not connect to a horizontal stack offset or within 2 feet (610 mm) above or below the offset where such horizontal offset is located more than four branch intervals below the top of the stack. (renumber remaining sections accordingly) C 6.0 905.0 Alternate Method for Vent System Sizing. C 6.1 Size of Vents 905.1 General. The size of vent piping shall be determined from the developed length and the total number of drainage fixture units connected in accordance with Table C 6.1 905.1. Vents shall be not less than one-half the required size of the drainage pipe size served as determined by Table C 5.4 704.3 for horizontal fixture branches and stacks nor less than 114 inches (32 mm) in diameter. The drainage system shall be vented by not less than one vent pipe which shall be not less than one-half the size of the required building drain and which shall extend from the building drain or extension of building drain to the outdoors. Vents shall be installed in accordance with Chapter 9 this chapter. C 6.2 905.2 Vent Stack. A vent stack shall be required for a drainage stack that extends five or more branch intervals above the building drain or horizontal branch. The developed length of the vent stack shall be measured from the lowest connection of a branch vent to the termination outdoors. C 6.3 905.3 Branch Vents. Where branch vents exceed 40 feet (12 192 mm) in developed length, such vent shall be increased by one pipe size for the entire developed length of the vent pipe. C 6.4 905.4 Venting Horizontal Offsets. Drainage stacks with horizontal offsets shall be vented where five or more branch intervals are located above the offset. The upper and lower section of the horizontal offset shall be vented in accordance with Section C 6.4.1 905.4.1 and Section C 6.4.2 905.4.2. C 6.4.1 905.4.1 Venting Upper