TA715/777 Installation and Operation Guide July 2008 WWW.TIMEAMERICA.COM 15990 N. Greenway-Hayden Loop, Suite D-500 Scottsdale, AZ 85260 Revision 2.00

Upload: vuxuyen

Post on 26-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

TA715/777 Installation and Operation Guide

July 2008

WWW.TIMEAMERICA.COM

15990 N. Greenway-Hayden Loop, Suite D-500

Scottsdale, AZ 85260

Revision 2.00

Page 2: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout
Page 3: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

iii

Table of Contents 1.0 Technical Specifications.......................................................................................................................- 1 -

1.1 Common to 715/777 Terminals .......................................................................................................- 1 - 1.2 Differences between 715 and 777 Terminals...................................................................................- 1 - 1.4 Optional Components ......................................................................................................................- 1 - 1.5 Maximum Absolute Ratings ............................................................................................................- 1 - 1.6 Bottom Connector Panel..................................................................................................................- 2 - 1.7 Internal Components........................................................................................................................- 2 -

1.7.1 Battery back-up module ...........................................................................................................- 2 - 1.7.2 Memory....................................................................................................................................- 3 - 1.7.3 Internal Serial Card ..................................................................................................................- 3 -

2.0 Unpacking and Inspection ....................................................................................................................- 5 - 2.1 Contents ...........................................................................................................................................- 5 -

3.0 Installation ............................................................................................................................................- 7 - 3.1 Location/Site Requirements.............................................................................................................- 7 -

3.1.1 Selecting a Location.................................................................................................................- 7 - 3.2 Mounting the Terminal ....................................................................................................................- 7 -

3.2.1 Model TA-715 Mounting Procedure........................................................................................- 7 - 3.2.2 Model TA-777 Mounting Procedure........................................................................................- 8 - 3.2.3 Communication Connections ...................................................................................................- 8 -

4.0 Terminal Configuration ........................................................................................................................- 9 - 4.1 Entering Technician Mode...............................................................................................................- 9 - 4.2 Terminal Setup.................................................................................................................................- 9 -

4.2.1 Ethernet ....................................................................................................................................- 9 - 4.2.2 Direct / Serial (RS232) or LAN (RS485)...............................................................................- 10 - 4.2.3 Modem...................................................................................................................................- 10 -

5.0 Maintenance .......................................................................................................................................- 11 - 5.1 Recovery from Memory Error .......................................................................................................- 11 - 5.2 How to Reset the Memory .............................................................................................................- 11 -

5.2.1 Location of Jumpers...............................................................................................................- 11 - 5.3 Battery Back-Up Modules .............................................................................................................- 12 -

6.0 Field Upgrades and Servicing.............................................................................................................- 13 - 6.1 Procedure – Internal Ethernet Card Installation.............................................................................- 13 -

6.1.1 TA-715 Ethernet Card Procedure...........................................................................................- 13 - 6.1.2 TA-777 Ethernet Card Procedure...........................................................................................- 14 -

6.2 Procedure – Internal Modem Card Installation..............................................................................- 15 - 6.1.1 TA-715 Modem Card Procedure............................................................................................- 15 - 6.1.2 TA-777 Modem Card Procedure............................................................................................- 16 -

6.3 Procedure – Internal Relay Card Installation.................................................................................- 17 - 6.1.1 TA-715 Relay Card Procedure...............................................................................................- 18 - 6.1.2 TA-777 Relay Card Procedure...............................................................................................- 18 -

Appendix – A ...........................................................................................................................................- 19 - External Wiring Diagrams........................................................................................................................- 19 -

A.1 Bells ..............................................................................................................................................- 19 - A.2 RS-232 ..........................................................................................................................................- 19 - A.3 RS-485 ..........................................................................................................................................- 20 -

Appendix – B............................................................................................................................................- 21 - Adding Transactions.................................................................................................................................- 21 - Appendix – C............................................................................................................................................- 22 - External Connectors .................................................................................................................................- 22 - Appendix – D ...........................................................................................................................................- 23 - Jumpers.....................................................................................................................................................- 23 -

Page 4: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout
Page 5: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 1 -

1.0 Technical Specifications

1.1 Common to 715/777 Terminals The following specifications are common to both versions of the TA-715/777 terminals. • Magnetic Badge reader (Track II) conforming to ISO 2894/3554/Barcode (Code 39) slot

reader model. • 128K of protected RAM. • Rechargeable backup battery (one year capacity) for the memory and Real Time clock. • Rechargeable backup battery for operation with auto shut-off for use during power outages. • Alarm light “!”, the LED lights when at least half the memory is in use, and blinks when the

memory of the clock is full. • RS232 and RS484 communications. • Audible tones.

1.2 Differences between 715 and 777 Terminals

TA-715 TA-777

Display 2x16 character LCD with back light display 2x16 character LCD with back light display

Function Keys 10 alpha-numeric keys – 6 programmable function keys (3 special control keys: Enter and backspace.

10 alpha-numeric keys – 8 programmable function keys (4 special control keys: Escape, Return, Line Up and Line Down).

Ethernet (Optional) Net Card type B Net Card Type B

1.3 Casings Metal for TA-777 terminals. Plastic for TA-715 terminals.

1.4 Optional Components The following are optional components for the 715/777 Terminals. • 14,400 bps internal modem. • 30 VDC 1A relay for controlling an announcement bell or a door lock. • Ethernet card. • (RF) Proximity reader/Wiegand (TA-777 only).

1.5 Maximum Absolute Ratings • Voltage: 115 VAC or 230 VAC • Ni-MH Back-up battery -9V / 160mA (For TA-715) • NI-Cd Back-up battery -7.2V / 900mA (For TA-777) • Maximum mains current: up to 100mA for 115 VAC, up to 50mA for 230 VAC. • Maximum ambient operating temperature for this battery: 0 – 50O C.

Page 6: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 2 -

1.6 Bottom Connector Panel The connector panel is located at the bottom of the casing.

Warning: The “HOST”, “Relay”, “Sensor”, “NET”, and “Reader” connections are for indoor use only and not intended for connection to exposed outdoor lines.

TA-715

Host: Serial RS232/485 Optional: Ethernet / Modem / Relay

TA-777

Host: RS232 / RS485 Net: Ethernet / Modem Reader: N/A Optional: Relay

1.7 Internal Components

1.7.1 Battery back-up module The terminal has two back-up battery modules, one for the real time clock memory and the other for operation during a power failure. The standard memory back-up module is a 1 year span lithium battery, keeping the internal clock running and the memory intact. The battery (in addition to the standard memory back-up) is self-contained. This allows operation of the terminal during a power failure as follows:

• TA-715 – In standard configuration (not including an option-card) for 40 minutes.

• TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout feature enables longer operation time. During a power failure, the user presses the [ON] key to activate the terminal. Data can then be entered and stored in the

Page 7: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 3 -

terminals memory. Timeout will cause the terminal to shutdown automatically after the last use of the terminal, until the [ON] key is pressed again.

Note: Plug the terminal into a main power source, for at least 18 hours continuously before relying on the battery backup.

1.7.2 Memory The TA-715 and TA-777 have 128 Kbyte of user memory, providing storage for data from more than 10,000 simple operations depending on programming table’s length, and the complexity of collected data.

1.7.3 Internal Serial Card The TA-777 terminal has a Serial RS-232/485 internal card for communication.

Page 8: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 4 -

Notes: ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________

Page 9: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 5 -

2.0 Unpacking and Inspection Check the box and the contents for any signs of damage that may have happened during shipment.

2.1 Contents The following items should be present:

• Terminal • Mounting Panel • Connecting/Splitter Box with cable (if ordered as serial clock) • Communication cable • Four Phillips flat head 3.5x30mm anchors, for terminal mounting • Mounting Template • Connector Cover • Template for mounting the terminal

Page 10: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 6 -

Notes: ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________

Page 11: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 7 -

3.0 Installation

3.1 Location/Site Requirements The terminal can be installed in any normal office or factory environment. Controlled environments are not required for proper operation of the terminal. However, installing and operating the terminal under adverse conditions may affect the functionality of the unit.

Warning: The “HOST”, “Relay”, “Sensor”, “NET”, and “Reader” connections are for indoor use only and not intended for connection to exposed outdoor lines.

3.1.1 Selecting a Location Consider the following environmental factors that may affect the operation of the terminal, when considering a location: • The cable should not be installed near EMI (Electromagnetic Interference) sources, such as:

o Motors, generators, alternators and transformers. o Air conditioners, elevators, etc. o Radio/Television transmitters, signal generators and internal communication networks.

• Cables should not be within: o 30 cm. (1 ft.) range from 5 KVA power lines or less. o 60 cm. (2 ft.) range from 5-10 KVA power lines. o 1.5 meters (5 ft.) range of power lines exceeding 10 KVA.

• Cables should not run parallel to power lines for more then 15 m. (49 ft.)

3.2 Mounting the Terminal Make sure the unit is unplugged, and that it is not connected to the network/PC.

Caution: The terminal should not be mounted where it will be exposed to extreme heat or cold, water, steam, violent vibrations, high electromagnetic radiation including high voltage power lines and electrical equipment.

Place the terminal near an easily accessible power source. Select an appropriate location for the terminal the recommended height from the floor is 120 cm. (3’ 11”).

3.2.1 Model TA-715 Mounting Procedure The following procedure explains how to mount the terminal to the wall. 1. Remove the back panel by lightly pushing outward on the tab and pulling down on the panel.

Also remove the connector cover from the bottom of the terminal. 2. Using the Mounting Template that came inside the box, place the template onto the wall at

the correct height, making sure that the template is level. 3. Drill holes using a 6 mm. (1/4”) drill bit. If the communication cable is to be wired through the

wall, wire one end. a. Warning: Live wires in the vicinity may contain 115v or 230v. Make sure not to drill into any

electric wires. Failure to heed this warning may result in serious injury or death. 4. Using the 4 screws that came with the terminal, screw the panel to the wall. 5. Slide the terminal over the panel hinges. 6. Connect the communication cable. 7. Plug the terminal into the power socket. 8. Re-Place the connector cover at the bottom.

Page 12: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 8 -

3.2.2 Model TA-777 Mounting Procedure 1. Using the mounting template that came inside the box, place the template onto the wall at the

correct height, making sure that the template is level. 2. Drill holes using a 6 mm. (0.23”) drill bit, and insert the plastic screw anchors

a. This package contains two sets of screw anchors: a set for a plaster wall and a set suitable for a brick wall. Use the set appropriate to your installation requirements.

b. Warning: Live wires in the vicinity may contain 115v or 230v. Make sure not to drill into any electric wires. Failure to heed this warning may result in serious injury or death.

3. Mount the holding bracket C into hole B and use a screw to secure the bracket to the wall. 4. Place two screws into holes A, making sure that the space between the screw’s head and the

wall is approximately 0.16” (4mm). 5. Hang the terminal on the wall using the two screws you just installed. 6. Attach element C to the terminal using screw E.

3.2.3 Communication Connections 1. Select a location for the connection box.

a. The box must be positioned where both the communication line and the terminal can be connected to it.

2. Plug the terminal communication cable into the connection box. 3. Wire an additional connection for Ethernet. 4. If an internal modem has been added and the modem is used, plug the phone line into the

modem connection. Do not use the terminal communication cable.

Page 13: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 9 -

4.0 Terminal Configuration The TA-715/777 Terminals can be connected to the host computer using either RS-232(Direct), RS-485(LAN), Ethernet or Modem.

4.1 Entering Technician Mode The TA-715/777 Terminals contain a built in configuration program called “Technician Mode”. Technician mode enables the setting up of the following options:

• Real Time Clock (RTC) Calibration • Baud Rate • Station ID settings • Modem Rings • Network Connection Settings

To enter technician mode: • For TA-715

o If the Terminal is displaying the date and time. Press [F1] and [F2] keys simultaneously 6 times.

o If the Terminal is displaying “No Prog”, press the [0] key 6 times. If the clock has a Barcode reader or a Magnetic reader, using a badge with six zeros

(000000) will work as well. o Use the [ENTER] key to move from one screen to the next. To return to the previous

screen, use the [Back Space] key. • For TA-777

o If the Terminal is displaying the date and time. Press the ↑ and the ↓ keys simultaneously 6 times.

o If the terminal is displaying “No Prog”, then press the [0] key 6 times. If the clock has a Barcode reader or a Magnetic reader, using a badge with six zeros

(000000) will work as well. o Use the [ENTER] key to move from one screen to the next. To return to the previous

screen, use the [Back Space] key.

4.2 Terminal Setup The following describes the different selections within Technician mode for setting up the TA-715 or TA-777. On the left in bold is the setting as it is displayed on the clock screen, on the right is the default setting.

4.2.1 Ethernet

1. ADJUST RTC (N/Y): N o Option is for internal clock calibration purposes.

2. SERIAL PORT 0 FOR BAUDRATE: 19200 3. STATION ID: 0

a. The Station ID is a unique identifier for multi-terminal communication. The range is from 0 to 31, and must match the setting in the software. Default is 0.

4. MODEM RINGS(0): N

Page 14: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 10 -

5. NETWORK (N/A/B): B NO/A-CARD/B-CARD a. Use the [F2] key to select option B.

6. POLLING SEC.: 0 PLEASE, WAIT… PRESS [ENTER] KEY

7. MY IP ADDRESS: xxx.xxx.xxx.xxx 8. GATEWAY ADDRESS: xxx.xxx.xxx.xxx 9. REMOTE ADDRESS: 000.000.000.000

a. This option will always be all zeros. 10. SUBNET MASK: xxx.xxx.xxx.xxx 11. MY PORT: 03734 12. HOST PORT: 03734

a. Must match My Port from option 12. 13. DISCONCT SEC: 30

PLEASE, WAIT… PRESS [ENTER] KEY

4.2.2 Direct / Serial (RS232) or LAN (RS485)

1. ADJUST RTC (N/Y): N 2. SERIAL PORT0 FOR BAUDRATE: 19200

a. Note: If using XactTime, the baud rate must be set to 9600. 3. STATION ID: 0

a. The Station ID is a unique identifier for multi-terminal communication. The range is from 0 to 31, and must match the setting in the software. Default is 0.

4. MODEM RINGS(0): N 5. NETWORK (N/A/B): N

NO/A-CARD/B-CARD

4.2.3 Modem

1. ADJUST RTC (N/Y): N 2. SERIAL PORT0 FOR BAUDRATE: 19200 3. STATION ID: 0

a. The Station ID is a unique identifier for multi-terminal communication. The range is from 0 to 31, and must match the setting in the software. Default is 0.

4. MODEM RINGS(0): 2 a. This can be any number between 1 and 9, and is the

setting on how many rings before the clock will answer. 5. NETWORK (N/A/B): N

NO/A-CARD/B-CARD

Page 15: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 11 -

5.0 Maintenance

5.1 Recovery from Memory Error If the terminal gives a memory error, a message “MEM CRASH” will appear on the screen. • For TA-715

1. Press the [0] key 6 times. 2. Press the [Enter] key once. 3. Press the [F2] key 3 times. 4. Press the [F5] key twice. 5. Press the [F2] key 3 times.

o The message “CLEAR MEMORY?” will appear on the display. 6. Press the [F5] key once.

o The message “MEMORY CLEARED” will appear on the display. 7. The message “NO PROG” will now be on the display. 8. Program the clock from within the software.

o Note – From TA-100Pro or GenPro/SQL on the polling screen when the clock is selected to the right, press CTRL+ALT+A. It will ask you to send the application to the clock, select Yes; then click the poll button.

• For TA-777

1. Press the [0] key 6 times. 2. Press the [Enter] key once. 3. Press the ↑ key 3 times. 4. Press the ↓ key twice. 5. Press the ↑ key 3 times.

o The message “CLEAR MEMORY?” will appear on the display. 6. Press the ↓ key once.

o The message “MEMORY CLEARED” will appear on the display. 7. The message “NO PROG” will now be on the display. 8. Program the clock from within the software. 9. Program the clock from within the software.

o Note – From TA-100Pro or GenPro/SQL on the polling screen when the clock is selected to the right, press CTRL+ALT+A. It will ask you to send the application to the clock, select Yes; then click the poll button.

5.2 How to Reset the Memory

Warning: This function should be performed by qualified personnel only. It requires working with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source.

5.2.1 Location of Jumpers Use the following steps reset the memory, causing a Memory Crash.

1. Unplug the terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds of being unplugged from the power.

2. Unscrew and remove the front panel. 3. Remove the J3 jumper from the 1-2 position and place it in the 2-3 position. 4. Remove the J3 jumper from position 2/3 and put back into the 1/2 position.

Page 16: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 12 -

5. Replace the front panel, and insert the screws. 6. Plug the Terminal back into a power source and make sure that “MEM CRASH” appears

in the terminal display. 7. Follow the steps from section 5.1 on recovering from the “MEM CRASH” state.

5.3 Battery Back-Up Modules The TA-7xx terminals have two back-up battery modules, one for the real time clock memory and the other for operation during a power failure. The standard memory back-up module is a lithium battery, which will keep the internal clock running and the memory intact, for 30 days during a power failure. The back-up battery provided (in addition to the standard memory back-up) is a self-recharging system which allows the terminal to be operated during a power failure. The battery provides power for 1-1/2 net hours of use. A shut down time-out feature enables the terminal to operate for more extended periods of time. During a power failure, the user presses the [ON] key to activate the terminal. Data can then be entered and stored in the terminal’s memory. The time-out will cause the terminal to shut down automatically after the last use of the terminal, until the [ON] key is pressed again.

Warning: Risk of explosion if the lithium battery is replaced by an incompatible battery. You must dispose of used batteries as per the manufacturer’s instructions.

Page 17: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 13 -

6.0 Field Upgrades and Servicing One of the features of the TA-7xx series terminals is the ability to do field upgrades and servicing. This section provides an explanation on how to perform the following upgrades:

• Internal Ethernet Card Installation • Internal Modem Card Installation • Internal Relay Card Installation

Warning: These functions should only be performed by qualified personnel only. It requires working with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source.

6.1 Procedure – Internal Ethernet Card Installation

NOTE: Refer to the section 4.0 for additional information of the configuration setting for this option.

6.1.1 TA-715 Ethernet Card Procedure

1. Unplug the Terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds.

2. Unscrew and remove the front panel. 3. You may need to punch out the opening for the accessory connection, and cut away

1/16” on top and 1/16” to the left or the opening to make room for the RJ-45 connector.

4. Install the Ethernet card into the TA-715 terminal using the below image as a reference.

Page 18: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 14 -

5. Once the card is installed properly, it should look like the image below.

6. Replace the front panel, insert the screws. 7. Plug the terminal back into a power source and make sure that the date/time appears in

the terminal display. 8. Plug the Ethernet cable into newly installed Ethernet card.

6.1.2 TA-777 Ethernet Card Procedure

1. Unplug the Terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds of being unplugged from the power.

2. Unscrew and lift up on the front panel, it will hinge back. 3. Line up the pins to the connectors on the board as shown in the picture below.

Page 19: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 15 -

4. Slide the pins into the connector until the board rests on the two screw mounts. The card should be positioned as per picture below.

5. Replace the front panel, insert the screws. 6. Plug the Terminal back into a power source and make sure that the date/time appears in

the terminal display. 7. Plug the Ethernet cable into newly installed Ethernet card.

6.2 Procedure – Internal Modem Card Installation This section explains how to install the internal Modem card option.

NOTE: Refer to the section 4.0 for additional information of the configuration setting for this option.

6.1.1 TA-715 Modem Card Procedure

1. Unplug the Terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds.

2. Unscrew and remove the front panel. 3. Install the Modem card into the TA-715 terminal using the below image as a reference.

Page 20: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 16 -

4. Once the card is installed properly, it should look like the image below.

5. Replace the front panel, replacing the screws. 6. Plug the Terminal back into a power source and make sure that the date/time appears in

the terminal display. 7. Plug the phone cable into newly installed modem card.

6.1.2 TA-777 Modem Card Procedure

1. Unplug the Terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds of being unplugged from the power.

2. Unscrew and lift up on the front panel, it will hinge back. 3. Locate locations J15 and J16 on the board. These will need to have the connections

soldered together. See image below for a reference.

Page 21: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 17 -

4. Line up the pins to the connectors on the board as shown in the picture below. Slide the pins into the connector until the modem board rests on the two screw mounts

5. The card should be positioned as per picture below.

6. Replace the front panel, insert the screws. 7. Plug the terminal back into a power source and make sure that the date/time appears in

the terminal display. 8. Plug the phone cable into newly installed modem card.

6.3 Procedure – Internal Relay Card Installation This section explains how to install the internal Modem card option.

NOTE: Refer to the section 4.0 for additional information of the configuration setting for this option.

Page 22: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 18 -

6.1.1 TA-715 Relay Card Procedure

1. Unplug the terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds.

2. Unscrew and remove the front panel. 3. Install the relay card into the TA-715 terminal. 4. Once the card is installed properly, it should look like the image below.

5. Replace the front panel, replacing the screws. 6. Plug the Terminal back into a power source and make sure that the date/time appears in

the terminal display.

6.1.2 TA-777 Relay Card Procedure

1. Unplug the terminal and make sure that it is powered off. a. The terminal will shut down after 15 seconds of being unplugged from the power.

2. Unscrew and lift up on the front panel, it will hinge back. 3. Remove the cover for the MOD/REL port. 4. Place the card as show in the image below, plugging the ribbon cable in the connection

with the red square.

5. Replace the front panel, insert the screws. 6. Plug the Terminal back into a power source and make sure that the date/time appears in

the terminal display.

Page 23: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 19 -

Appendix – A

External Wiring Diagrams

A.1 Bells To connect a bell system to the clock use the cable and connection box that came with the clock and wire it according to the following diagram: TA-715 – Cable 620047 TA-777 – Cable 620178 Signal Control: With the optional internal relay card, the terminal can control a 12 VDC, 1 Amp dry-contact circuit. The signal relay can turned on by time of day for bell ringing. The duration time is also programmable.

A.2 RS-232 RS-232 uses the DB9 Serial Adapter (Part: CBL-1195) and a serial cable (Part: 620046). Note: Supported distances for cabling is currently 50 feet.

Page 24: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 20 -

A.3 RS-485 RS-485 uses the External converter (Part: ACC-2050) and a standard 4 wire phone style cable. Using this method, you can connect multiple clocks thru a single serial connection on the Host PC.

Page 25: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 21 -

Appendix – B

Adding Transactions Use the following steps to add transactions into the terminal:

NOTE: The clock is programmed initially with a supervisor badge of 11111. This badge number will normally be cleared the first time you program the clock if you use different badge numbers or badge lengths for supervisors.

Step 1. Enter the supervisor badge number and press [ENTER]. Step 2. From the menu select (1) – Add. Step 3. Enter the date of the transaction in MM/DD/YY format, then press [ENTER]. Step 4. Enter the time of the transaction in military time, then press [ENTER]. Step 5. Enter the badge number of the employee, then press [ENTER]. Step 6. Enter the function for the transaction. Step 7. Terminal will request finger of the employee Step 8. Press [BACK SPACE], to get back to the previous menu.

Page 26: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 22 -

Appendix – C

External Connectors HOST RJ-45 (8 pin) – P4 Communication with Host computer

Pin Signal Value 1 NC 2 RS-485 (-TRX) 0 – 5 Volt 3 RS-485 (+TRX) 0 – 5 Volt 4 GND 5 RS-232 (TXD) -12: +12Vdc 6 RS-232 (RXD) -12: +12Vdc 7 NC 8 NC

RJ-45 (Ethernet – P1 Optional net card A. For Ethernet: (Set J15, J16 and J17)

Pin Signal Value Remarks 1 Transmit data TX+ 2 Transmit data TX- 3 Receive data RX+ 4 NC/Vin/Shield 10Base-T/Power over LAN/100Base-T 5 NC/Vin/Shield 6 Receive data 7 NC/GND/Shield 10Base-T/Power over LAN/100Base-T 8 NC/GND/Shield 10Base-T/Power over LAN/100Base-T

B. For 14,400 Modem: (Set J15, J16 and J17)

Pin Signal Value 1 NC 2 NC 3 Ring OP- 4 TIP OP+ 5,6 NC

C. For 2,400 Modem +I/O

Pin Signal Function 1 Relay 1 Output 2 Sensor 1 Input 3 Ring Modem 4 TIP Modem 5 Sensor 2 Input 6 Relay 2 Output

D. For 14,400 Modem: (Set J15, J16 and J17)

Pin Signal 2 VCC 4 DATA 7 GND

Page 27: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 23 -

Appendix – D

Jumpers Printed side (PCB No. 310-C112-05-C)

Page 28: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 24 -

Display Card – TA777

Display Card – TA715

Page 29: TA-715 777 Manual - 2 00 777 Manual - 2 00.pdf5.2 How to Reset the Memory ... • TA-777 – In standard configuration (not including an option-card) for 1-1/2 hours. A shut down timeout

- 25 -

Miscellaneous

* - TA-715 Terminals ** - TA-777 Terminals