systems accessories - norpak · hytrol conveyor catalog 05072015 hytrol conveyor company, inc....

3
HYTROL CONVEYOR CATALOG 02012015 HYTROL CONVEYOR COMPANY, INC. 14.23 SINGLE POWERED PIVOT DIVERTER CAPACITY–75 lbs. maximum package weight. PACKAGE SIZE–Minimum 6 in. wide x 9 in. long, maximum 12 in. wide x 21 in. long. NOTE: Small packages must not be top heavy. DIVERTER SPEED–AC Drive 42-420 FPM. DIVERTER MECHANISM–Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING–Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 21 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE: ACC belt must be opposite discharge side. Widths over 22 in. BR contact Factory. CYCLES–Up to 40 times per minute. DRIVE– HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power. AIR CYLINDER–1 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE–Single solenoid 4-way valve with speed controls, in. NPT valve ports. Requires maintained electrical signal of 115V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding. AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .014 cu. ft. per cycle. NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). The Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. 5-1/4" CENTERLINE OF DRIVEWHEEL SHAFT "ACC" DRIVE BELT FLOW FLOW 30˚ MIN. TO DISCHARGE END OF SECTION 21" MIN. TO INFEED END OF SECTION 21" FLOW "ACC" DRIVE BELT L.H. SPUR R.H. DIVERTER L.H. DIVERTER R.H. SPUR Standard SpecificationS SyStemS acceSSorieS DOUBLE POWERED PIVOT DIVERTER The Double Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines. "ACC" DRIVE BELT R.H. SPUR L.H. SPUR L.H. DIVERTER R.H. DIVERTER 9" MIN. TO DISCHARGE END OF SECTION 21" MIN. TO INFEED END OF SECTION 21" FLOW 5-1/4" CENTERLINE OF DRIVEWHEEL SHAFT "ACC" DRIVE BELT FLOW FLOW 30˚ CAPACITY–75 lbs. maximum package weight. PACKAGE SIZE–Minimum 6 in. wide x 9 in. long maximum 34 in. wide x 46 in. long. NOTE: Small packages must not be top heavy. DIVERTER SPEED–AC Drive 42-420 FPM. DIVERTER MECHANISM–Four rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts. MOUNTING–Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 39 in. BR, RH or LH Diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE: ACC belt must be opposite discharge side. Widths over 22 in. BR, contact Factory. CYCLES–Up to 40 times per minute. DRIVE– HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power. AIR CYLINDER–1 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends. AIR VALVE–Single solenoid 4-way valve with speed controls. in. NPT valve ports. Requires maintained electrical signal of 115 V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding. AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I. Free air consumption at 60 P.S.I., .028 cu. ft. per cycle. NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard). Standard SpecificationS

Upload: others

Post on 06-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SyStemS acceSSorieS - Norpak · Hytrol Conveyor Catalog 05072015 HYTROL CONVEYOR COMPANY, INC. 14.25 SyStemS acceSSorieS e24 electric powered Pivot diverter The E24 Powered Pivot

Hytrol Conveyor Catalog02012015

HY

TR

OL

CO

NV

EY

OR

CO

MP

AN

Y, IN

C.

14.23

Single Powered Pivot diverter

CAPACITY–75 lbs. maximum package weight.

PACKAGE SIZE–Minimum 6 in. wide x 9 in. long, maximum 12 in. wide x 21 in. long. NOTE: Small packages must not be top heavy.

DIVERTER SPEED–AC Drive 42-420 FPM.

DIVERTER MECHANISM–Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

MOUNTING–Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 21 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE: ACC belt must be opposite discharge side. Widths over 22 in. BR contact Factory.

CYCLES–Up to 40 times per minute.

DRIVE–1/2 HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power.

AIR CYLINDER–1 1/4 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends.

AIR VALVE–Single solenoid 4-way valve with speed controls,1/4 in. NPT valve ports. Requires maintained electrical signal of 115V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding.

AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .014 cu. ft. per cycle.NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard).

The Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

5-1/4"

CENTERLINE OF DRIVEWHEEL SHAFT

"ACC" DRIVE BELT

FLOW

FLOW

30˚

MIN. TO DISCHARGEEND OF SECTION

21"

MIN. TO INFEEDEND OF SECTION

21" FLOW

"ACC" DRIVE BELT

L.H.SPUR

R.H.DIVERTER

L.H.DIVERTER

R.H.SPUR

• Standard SpecificationS

SyStemS acceSSorieS

double Powered Pivot diverterThe Double Powered Pivot Diverter is designed for use with Models 138-ACC & 190-ACC Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

"ACC" DRIVE BELT

R.H.SPUR

L.H.SPUR

L.H.DIVERTER

R.H.DIVERTER

9"MIN. TO DISCHARGE

END OF SECTION21"

MIN. TO INFEEDEND OF SECTION

21" FLOW

5-1/4"

CENTERLINE OF DRIVEWHEEL SHAFT

"ACC" DRIVE BELT

FLOW

FLOW

30˚

CAPACITY–75 lbs. maximum package weight.

PACKAGE SIZE–Minimum 6 in. wide x 9 in. long maximum 34 in. wide x 46 in. long. NOTE: Small packages must not be top heavy.

DIVERTER SPEED–AC Drive 42-420 FPM.

DIVERTER MECHANISM–Four rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

MOUNTING–Complete unit bolts to 138-ACC 13 in. to 22 in. BR only or 190-ACC 13 in. to 39 in. BR, RH or LH Diversion 30˚ spur discharge (spur not included). Minimum elevation 15 in. (138-ACC) or 16 in. (190-ACC). NOTE: ACC belt must be opposite discharge side. Widths over 22 in. BR, contact Factory.

CYCLES–Up to 40 times per minute.

DRIVE–1/2 HP motor with AC type variable speed controller. Select 230V–3 Ph. 60 Hz. or 115V–1 Ph. 60 Hz. power.

AIR CYLINDER–1 1/4 in. dia. bore x 1 in. stroke, double acting with internal rubber bumpers both ends.

AIR VALVE–Single solenoid 4-way valve with speed controls. 1/4 in. NPT valve ports. Requires maintained electrical signal of 115 V–1 Ph. 60 Hz. from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .09 amps holding.

AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I. Free air consumption at 60 P.S.I., .028 cu. ft. per cycle. NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard).

• Standard SpecificationS

Page 2: SyStemS acceSSorieS - Norpak · Hytrol Conveyor Catalog 05072015 HYTROL CONVEYOR COMPANY, INC. 14.25 SyStemS acceSSorieS e24 electric powered Pivot diverter The E24 Powered Pivot

HY

TR

OL

CO

NV

EY

OR

CO

MP

AN

Y,

INC

.

Hytrol Conveyor Catalog02012015

14.24

SyStemS acceSSorieS

CAPACITY–75 lbs. maximum package weight.

PACKAGE SIZE–Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side.

DIVERTER SPEED– 50-200 FPM set on Motor Controller

DIVERTER MECHANISM–Two rows of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

MOUNTING–Bolts to 190-E24 15 in. to 39 in. BR, RH or LH diversion 30˚ spur discharge (spur not included). Minimum elevation 14 in. NOTE: O-rings must be opposite discharge side. Widths over 39 in. BR contact factory.

CYCLES–Up to 40 times per minute.

MOTOR–24 VDC motor, 3 amps per motor, one each Divert Bank.

MOTOR CONTROLLER– Controls and Protects Motor, one each Divert Bank.

AIR CYLINDER–1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends.

AIR VALVE–Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main-tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding.

AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .064 cu. ft. per cycle.NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard).

CAPACITY–75 lbs. maximum package weight.

PACKAGE SIZE–Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy. NOTE: Product must be justified to divert side.

DIVERTER SPEED– 50-200 FPM set on Motor Controller

DIVERTER MECHANISM–One row of 3 1/8 in. dia. wheels with urethane treads driven by 3/8 in. dia. urethane belts.

MOUNTING–Complete unit bolts to 190-E24 15 in. to 21 in. BR, RH or LH diversion 30˚ spur dis-charge (spur not included). Minimum elevation 14 in. NOTE: O-rings must be opposite discharge side. Widths over 39 in. BR contact factory.

CYCLES–Up to 40 times per minute.

MOTOR–24 VDC motor, 3 amps per motor, one each Divert Bank.

MOTOR CONTROLLER– Controls and Protects Motor, one each Divert Bank.

AIR CYLINDER–1 1/4 in. dia. bore x 2 in. stroke, double acting with internal rubber bumpers both ends.

AIR VALVE–Single solenoid 4-way valve with speed controls,1/8 in. NPT valve ports. Requires main-tained electrical signal of 24VDC watt from photo cell, limit switch, etc. (not supplied). Diverter will stay in diverted position until signal is broken. Current consumption is .32 amps holding.

AIR REQUIREMENTS–Minimum pressure 60 P.S.I., maximum 125 P.S.I., free air consumption at 60 P.S.I., .032 cu. ft. per cycle.NOTE: To eliminate contaminants in air supply line, a filter-regulator should be installed prior to the air valve (not supplied as standard).

e24 Single Powered Pivot diverter

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/19/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog-Int

kchurchillkchurchill

MIN. TO DISCHARGEEND OF SECTION

4-1/2"

MIN. TO INFEEDEND OF SECTION

7-1/2"

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/19/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog-Int

kchurchillkchurchill• Standard SpecificationS

e24 double Powered Pivot diverterThe Double Powered Pivot Diverter is designed for use with Models 190-E24 & 190-E24EZ Accumulating Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

• Standard SpecificationS

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/19/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog-Int

kchurchillkchurchill

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/18/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog60inch-Int

kchurchillkchurchill

MIN. TO DISCHARGEEND OF SECTION

7-1/2"

6 MIN. TO INFEEDEND OF SECTION

7-1/2"

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/18/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog

kchurchillkchurchill

ECN

DWG NO

DESIGNED BY

CHECKED BY

HYTROL

JONESBORO, ARKANSASCONVEYOR CO., INC.

HYTROL

DATE

DATE

MODELS

STANDARD TOLERANCESUNLESS OTHERWISE SPECIFIED

FRACTIONS ±1/64DECIMALS ±.005

ANGLES ±1°

8/18/2011

THIS DRAWING CONTAINS CONFIDENTIAL DESIGNS AND INFORMATION WHICH ARE THE PROPERTY OF HYTROL CONVEYOR COMPANY INC. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN MAY NOT BE DISCLOSED OR DUPLICATED IN

WHOLE OR PART, UTILIZED IN ANY OTHER WORK, OR USED FOR MANUFACTURE OF DESIGNS WITHOUT THE PRIOR WRITTEN

PERMISSION OF HYTROL CONVEYOR COMPANY INC.

DRAWN BY DATE 8/18/2011

PAINT CLASS REVISIONSPARE PART MFG CLASS

CCatalog

kchurchillkchurchill

RHSpur

RHSpur

LHSpur

LHSpur

RH DiverterLH Diverter

The Powered Pivot Diverter is designed for use with Models 190- E24 & 190-E24EZ Conveyor. Products are automatically diverted onto adjacent 30˚ spur lines.

RH DiverterLH Diverter

Page 3: SyStemS acceSSorieS - Norpak · Hytrol Conveyor Catalog 05072015 HYTROL CONVEYOR COMPANY, INC. 14.25 SyStemS acceSSorieS e24 electric powered Pivot diverter The E24 Powered Pivot

Hytrol Conveyor Catalog05072015

HY

TR

OL

CO

NV

EY

OR

CO

MP

AN

Y, IN

C.

14.25

SyStemS acceSSorieSe24 electric poweredPivot diverterThe E24 Powered Pivot Diverter is designed for use with Models E24 & E24EZ Accumulating Conveyor. Products are diverted onto adjacent 30˚ spur lines. The electric linear actuator rotates the diverter sheave assembly to divert at a 30˚ angle. The vertical lift of the sheave assembly allows the diverter to have more control of the package which provides a more positive divert.

4 1/2" MIN

7

4 1/2" MIN

7" ± 1"

30

7" ± 1"

30

CAPACITY–75 lbs. maximum package weight.

PACKAGE SIZE–Minimum 4 in. wide x 6 in. long, maximum 26 in. wide x 36 in. long. NOTE: Small packages must not be top heavy.

DIVERTER SPEED–24VDC, 35-155 FPM.

DIVERTER MECHANISM–Row of 2 3/4 in. dia. wheels with urethane treads driven by 3/16 in. dia. urethane belts.

CYCLES–Up to 30 cases per minute.

MOTOR–24VDC motor, 3 amps per motor.

CONTROLS INPUT–18-24V at 1.9-4.2mA

DRIVE CURRENT REQUIREMENTS–20-28V DC 4 AMP

AVAILAbLE wIDTHS –22”, 24”, 26”, 28”, 30” OAW

• Standard SpecificationS

24TMe

lH diverterrH diverter