Study of the fragmentation of Carbon ions for medical applications
Protons (hadrons in general)especially suitable for deep-sited
tumors (brain, neck base, prostate)and fat people
Giovanni De LellisNapoli University
![Page 2: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/2.jpg)
Dose modulation
From the overlap of close peaks (close energies), a conformational
profile is obtained
The patient is rotated so to avoid a long exposure time of the
healthy tissues
Size of the sick part
![Page 3: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/3.jpg)
Carbon beam
Same energy deposit profile as protons but with larger energy loss per unit length
one ionization every ~ 10nm
(DNA helix ~ 2nm)
![Page 4: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/4.jpg)
Charge and mass measurement
• Density of energy along the track path Z2
• Multiple scattering or magnetic field provides either p or p
• From the combined measurement, we can get p and the mass A,Z
Open issues•Knowledge of the Carbon cross-section with human tissues•In particular the exclusive cross-section in the different channels so to predict the detailed irradiation of the neighboring tissues optimization of the therapy with higher effectiveness
![Page 5: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/5.jpg)
Facilities in Europe
• Typically joint beam (physicists) and therapeutic (biological, medical) facilities.
• In Europe, a high energy (few hundred MeV/nucleon) carbon beam is at GSI, Darmstadt, Germany
• In Italy (Pavia, close to Milan) the CNAO under construction, starting on 2009
• Proton centers more numerous• In Italy (linked with INFN) one proton center
operative in Catania, Sicily
![Page 6: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/6.jpg)
Exposure of an ECC to 400 Mev/u Carbon ions
ECC structure: 219 OPERA-like emulsions and 219 Lexan sheets 1 mm thick (73 consecutive “cells”)
exposed to 400 Mev/u Carbon ionsLexan: = 1.15 g/cm3 and electron density = 3.6 x 1023/cm3
e.g. Water 3.3 x 1023/cm3
Cell structure
LE
XA
N
LE
XA
N
LE
XA
N
R0 R1 R2
R0: sheet normally developed after the exposure
R1: sheet refreshed after the exposure (3 days, 300C, 98% R.H.)
R2: sheet refreshed after the exposure (3 days, 380C, 98% R.H.)
![Page 7: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/7.jpg)
Carbon exposure at HIMAC (NIRS-Chiba)
![Page 8: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/8.jpg)
C ions angular spectrum
Slope X
Slo
pe
Y
slope X
(3 )
slope Y
(3 )
P1-0.150 ±0.004
-0.003 ±0.005
P2-0.017 ±0.004
-0.002 ±0.005
P3 0.134 ±0.004
-0.001 ±0.005
3.4 cm2 scanning in each sheet (all sheets scanned)
![Page 9: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/9.jpg)
Vertex reconstructionAbout 2300 vertices analyzed
C
3 cm
![Page 10: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/10.jpg)
Impact parameter distribution
Hydrogen tracks Helium tracks
µm µm
![Page 11: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/11.jpg)
Track volume: sum of the areas of the clusters belonging to the track
BG, mip
Z > 1
p
Upstream sheet
Downstream sheet(about 5 cm)
p Z > 2
one sheet – R0 type one sheet – R1 type
Downstream sheet(about 5 cm)
Upstream sheet
![Page 12: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/12.jpg)
R0 vs R1 and R1 vs R2 scatter plot
H
He
He
![Page 13: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/13.jpg)
Charge identification
Z = 2
Z = 3
Z = 4
5 R1 VS 5 R2 (2 cm) 10 R1 VS 10 R2 (4 cm)
15 R1 VS 15 R2 (6 cm)
20 R1 VS 20 R2 (8 cm)
Z = 4
Z = 3
Z = 2
Z = 5
Z = 6
![Page 14: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/14.jpg)
Charge separation
Journal of Instrumentation 2 (2007) P06004
![Page 15: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/15.jpg)
Charge distribution of secondary particlescharge reconstruction efficiency
Inefficiency Charge = 0Charge efficiency = (2848-27)/2848 =
99.1±0.2%
![Page 16: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/16.jpg)
Carbon interaction
Bragg peak
Contamination at the % level
Track multiplicity
![Page 17: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/17.jpg)
Angular distribution of secondary particlesElastic scattering Hydrogen
Helium
large angle (a few percent)
Lithium
![Page 18: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/18.jpg)
Cross-section measurement• A volume of about 24cm3 was analyzed
• 2306 interaction vertices found (475 elastic)
• The number of events with maximal charge as Lithium (z = 3) is 183, as beryllium (z = 2) is 118, as Boron (z = 1) is 258
( 1) 2330 150
( 2) 1060 100
( 3) 1650 120
z mbarn
z mbarn
z mbarn
Toshito et al.
Toshito et al.Toshito et al.
![Page 19: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/19.jpg)
Interaction length for different secondary ions
14.0 1.2H mm 14.0 1.2H mm
14.0 1.2H mm
14.0 1.2H mm 19.3 2.3He mm
![Page 20: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/20.jpg)
Very preliminary• 8Be He + He (10-16 s) • Q value 90 keV
8( ) 225 50C Be mbarn
(rad)
He
He
Real event
He-proton opening angle
![Page 21: Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck](https://reader035.vdocuments.mx/reader035/viewer/2022062407/56649d595503460f94a388a3/html5/thumbnails/21.jpg)
Conclusions• The charge separation capability is about 5 sigma
for protons and helium already with less than 10 plates where other detectors fail
• The separation between boron and carbon requires 30 plates to reach 2.5 sigma
• Emulsions provide unprecedented results in the light ion identification
• Preliminary results cross-section measurementPossible improvements
•Improve the identification capability for short tracks•Measure the momentum for isotope discrimination•Extend the energy range for cross-section measurements