step 7 v14 new functions - ad.siemens.com.cn...simatic step 7 in the tia portal highlights of step 7...
TRANSCRIPT
-
STEP 7 V14
New functions
Programming; editors and usability; system functions Unrestricted © Siemens AG 2016
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 2
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Support of new CPU‘s
Functions
• S7-1500 T-CPU family with integrated motion control
functionality like “Synchronous axis” and “Output cam”
• CPU 1518(F)-4 PN/DP ODK (Open Development Kit):
• Integration of C/C++ functions using ODK 1500S
• Integration of Simulink® models using Target 1500S
• CPU 1516pro (F)-2 PN
• Failsafe S7-1500 Software Controller
• CPU 1212FC
S7-1500T-CPU CPU 1518(F)-4 PN/DP ODK
CPU 1516pro(F)-2 PN
Seite 3
CPU 1507SF & CPU 1515SP PC F
New New
New
New
CPU 1212FC New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Grouping of devices in the project navigation
Functions
• Grouping of I/O devices/slaves
in the project navigation
Benefits
• Technological merging
of devices
• Devices as part of large applications
can be located more quickly
Page4
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Horizontal or vertical division of the network/device view
Functions
• The arrangement of the network/device view
can be chosen freely.
Benefits
• The vertical division of the device view provides
its user with a structured overview of all devices
and can be used for editing the most important
device properties.
• The horizontal division of the network view is
most helpful for editing all of the parameters of
the configured connections.
Page5
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Synchronization of the network and topology view
Network view Topology view
Topology view after synchronization
Functions
• The arrangement of the devices in the
topology view can be synchronized with
the network view.
Benefits
• Standardized user interface for both the
device and topology view
• Fast adjustment of the topology view
Page6
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Firmware update under online accesses (also called LifeList)
Functions
• In addition to the CPU/IM, the
online & diagnostics editor under
online accesses displays all
plugged-in modules.
• Modules can be updated
individually.
Benefits
• The user can perform a device
update regardless of whether all
modules have been configured in
advance.
Page7
New
-
Unrestricted © Siemens AG 2016
Profile definition in the hardware catalog
• The user-defined hardware catalog allows
quick and easy access to frequently used
modules.
• Article number-specific
• Defined profiles can be exported via
Tools/Settings/General.
Mass operations for assigning a new
controller to I/O devices
• New context menu entries for individual
stations guarantee a quick assignment to I/O
controllers.
• Multiple selection possible
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Collection of useful functional extensions
Page8
New
New
-
Unrestricted © Siemens AG 2016
Changing device properties "in-place"
• Important properties such as IP addresses
and device names can be changed directly
in the network view.
Detailed information in the address
overview
• The device name and the I/O system help
to clearly identify modules.
• The user can view the size of the address
area at a glance.
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Collection of useful functional extensions
New
Page9
New
New New New
-
Unrestricted © Siemens AG 2016
Assigning a PN device name as a mass
operation
• The PROFINET device name can be
assigned as a mass operation in the network
view/IO-communication.
Topology comparison in table view
• The table view allows a compact overview of
both the online and offline configuration.
• They can easily be synchronized.
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Collection of useful functional extensions
Page10
New
New
-
Unrestricted © Siemens AG 2016
Structured IO tags
• Graphic display of structured IO tags in the
table
• Display of overlapping variables
SIMATIC STEP 7 in the TIA Portal – Hardware and network editor
Collection of useful functional extensions
Page11
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 12
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – New editor functions
SCL networks in LAD/FBD
Functions
• SCL networks can be inserted in an LAD (FBD) block.
Benefits
• Depending on the use case, the ideal programming
language can be selected freely within a block, e.g. LAD
for links and SCL for subsequent mathematical
calculations, so that programming becomes considerably
more efficient.
• An SCL network, for example, can now be inserted
instead of the Calculate Box.
Page 13
S7-1200 S7-300/400/WinAC
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – New editor functions
SCL regions – "networks" for SCL
Functions
• New keyword REGION (cf. C#)
• Any name including spaces and special characters
• Nested regions
• Open/closed status is saved
• Synchronized navigation column including the display of
syntax errors
Benefits
• Code structuring
• Enhanced overview and readability
• Simple navigation even in large blocks
Page 14
S7-1500 S7-1200 S7-300/400/WinAC
New
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – New editor functions
Hiding block parameters (LAD/FBD)
Functions
• Useable for:
• FBs and FCs
• All parameter types (In, Out and InOut)
• All data types
• Can be found in the properties of the parameter
• Adjustable options:
• Show
• Hide for assigned and unassigned parameters
• Hide if no parameter is assigned
Benefits
• Improved overview of blocks with many optional
parameters
Page 15
S7-1200 S7-300/400/WinAC
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – New editor functions
Automatic numbering of blocks
Function
• Block numbers required for internal
processing are assigned automatically by the system
(setting in the block properties)
• The system resolves conflicts in the block numbers
automatically, e.g. due to copying processes.
• Conflicts can be resolved automatically by the system -
even for know-how-protected blocks. A password is not
required (prerequisite: Encryption was implemented using
>= V13 SP1)
Benefits:
• User programs can be programmed symbolically
• The user does not have to concern himself with numbers
and number conflicts
Copy and paste
The system renumbers the
blocks and resolves the
conflict during the
translation.
S7-1500 S7-1200 S7-300/400/WinAC
Page 16
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – New editor functions
Comparing blocks using checksums
Functions
• Source codes can be compared using many filter options.
• Evaluation of checksums in the user program
Benefits
• Differences in blocks are recognized more quickly.
• The reasons for differences can be identified more quickly
(e.g. the data type used has changed)
• Filters enable a user-defined comparison
• Program changes can be detected during runtime and be
processed accordingly – for V14 the following evaluation
options are possible:
• Checksum for the complete standard program
• F signature for the safety program and safety hardware
Page 17
Old_Checksum = C153Q3
Cur_Checksum = XZA135
Program Compare:
PLC Program
changed
S7-1500 S7-1200 S7-300/400/WinAC
GetChecksum()
New
New
-
Unrestricted © Siemens AG 2016
Absolute address for standard blocks, also
for structures
• Structured tabs in standard blocks now show
the absolute address instead of the relative
offset
Go to definition within the
• UDT editor with tags of the type UDT
• DB editor with tags of the type UDT
• Interface editors with tags of the type
FB, DB, and UDT
Predefined block parameters
• The predefined block parameter is entered
automatically when the block is called
• With FCs/FBs for IN, OUT and INOUT
• With Intelli-Sense
SIMATIC STEP 7 in the TIA Portal – New editor functions
Collection of useful functional extensions
Page 18
New
New
New
-
Unrestricted © Siemens AG 2016
Declaring new tags as Temp
• New tags are declared as Temp by default
and not as bit memories
Network status on opening/closing a block
• Networks are displayed the same way they
were displayed the last time the block was
closed.
Block information with up to 125 characters
• For S7-1200/1500
SIMATIC STEP 7 in the TIA Portal – New editor functions
Collection of useful functional extensions
Page 19
New
New
New
-
Unrestricted © Siemens AG 2016
Hierarchical representation of the compile
results
• Display of the block subfolders
• Enhanced overview
SCL: Display all monitored values
• Context menu for showing/hiding
• All available tags are displayed
SCL: CTRL + Click for Go to definition
• Quick for defining a tag, FBs, ... jump via
hyperlink
SIMATIC STEP 7 in the TIA Portal – New editor functions
Collection of useful functional extensions
Page 20
New
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – New editor functions
Collection of useful functional extensions
Page 21
“Undo” also available offline
Global setting for Operand representation
and Tag information
New
New
-
Unrestricted © Siemens AG 2016
S7-Graph: Absolut_Info_Overlay
• Optimized display of the absolute address
(minimal column width)
S7-Graph: Symbolic jump/jump target
• Symbolic display of the jump and jump target
in the DetailedSequenceView.
S7-Graph: Hide Absolut_Info_Overlay
• The Absolut_Info_Overlay can now be
hidden using the context menu.
SIMATIC STEP 7 in the TIA Portal – New editor functions
Collection of useful functional extensions
New
New
New
New
Page 22
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 23
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – Language innovations
Array(*) for transferring arrays of variable length
Functions
• Array(*) as new parameter data type
• LOWER_BOUND, UPPER_BOUND for determining the
array boundaries
• STL, SCL, LAD, FBD
Benefits
• Pointer programming for arrays of varying lengths no
longer necessary
• Better runtime performance than pointer (Any/Variant) and
copying by MOVE_BLK
• Fully symbolic and improved readability
• Enables generic standard functions for arrays varying in
length
S7-1200 S7-300/400/WinAC
Page 24
New
New
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – Language innovations
Array of multi-instances
Functions
• Saving multi-instance data in an array
(STL, SCL, LAD, FBD)
• Multi-instances can be called in loops
• Applies to PID-Tos* as well
Benefits
• Drastic reduction of code
• Enhanced readability
• Efficient programming of mass calls
S7-1200 S7-300/400/WinAC
Page 25
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Language innovations
Indexed access to technology objects
Functions
• List technology object (TO) instances in an array of
DB_ANY
• Hand over DB_ANY to a technology object
• S7-1500: starting from FW V2.0
• S7-1200: starting from FW V4.2
Benefits
• Indexed access to TOs in slopes instead of separate
access requests
• Reduction of code
Page 35
New
S7-1500 S7-1200 S7-300/400/WinAC
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – Language innovations
Transfer instance as parameter
Functions
• Transfer of an instance to an FC/FB
• Call of the transferred instance in the FC/FB
• STL, SCL, LAD, FBD
Benefits
• Standardized functions to which dynamic
instances are transferred
• The used instance has to be defined at the block
call (not inside the block).
S7-1200 S7-300/400/WinAC
Page 27
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Language innovations
Constants
Function:
• Local and global constants can be used both in the code
and as array boundaries.
• For the declaration of a string, constants (local, global) can
now be used for the length as well.
Benefits:
• Arrays and strings can be adapted centrally by changing
the constant value.
• Thus, for example, programs with a centralized adjustment
to the availability of memory of CPUs can be adapted.
S7-1500 S7-1200 S7-300/400/WinAC
Page 28
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Language innovations
Serialize / Deserialize
Serialize data
• “Serialize” transforms structured
data in a byte array.
• “Deserialize” transforms a byte array
in a structure.
SERIALIZE
Structure
• Var1 : Byte
DESERIALIZE
2#0000_0001
2#0000_0000
S7-1500 S7-1200 S7-300/400/WinAC
Structure
• Var1 : Bool = true
• Var2 : Bool = false
• Var3 : Bool = false
• Var4 : Bool = false
• Var5 : Bool = false
• Var6 : Bool = false
• Var7 : Bool = false
• Var8 : Bool = false
Array of Byte can be
saved in the optimized
data area.
New
Page 29
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – Language innovations
Comparison of UDT tags
Functions
• Two variables of the same PLC data type can be
compared to each other.
• Check for consistency and inconsistency
• Available in STL, SCL, LAD, FBD
Benefits
• Symbolic programming using structured variables is now
possible without restrictions and with optimal runtime
performance.
S7-1200 S7-300/400/WinAC
Page 30
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Language innovations
Multi-lingual texts on the PLC
Functions
• Alarm texts and comments in the user program are
loaded* onto the controller in 3 languages.
Benefits
• Web server and display can display alarms in up to three
languages.
• Translations are retained when downloaded/uploaded.
• HMI Code Viewer and Graph-Viewer show the comments
and the code in three languages.
• Notes:
• Applies to S7-1500, 2 languages for S7-1200
• The alarms are loaded into the work memory. The contents are loaded into
the load memory.
Alarms and comments in three languages
S7-1500 S7-1200 S7-300/400/WinAC
Page 31
-
Unrestricted © Siemens AG 2016
Recursive block call in SCL
• Already available for LAD/FBD/STL
• For S7-1200/1500
Multiple assignment:
• Easy assignment of a value to any number
of tags (e.g. initialization)
New arithmetic functions:
• +=, -=, *=, /=
• For S7-1200/1500
SIMATIC STEP 7 in the TIA Portal – Language innovations
Collection of useful functional extensions
FC/FB
Page 32
New
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 33
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
S7-1500
SIMATIC STEP 7 in the TIA Portal – New and improved system functions
Access to alarm texts from the user program
Functions
Virtual HMI - Same functional scope as
SIMATIC HMI:
• Subscription for specific display classes
(filter option)
• Selection of up to 3 languages
Benefits
Easy connection of third-party products
to the alarm system of the S7-1500
S7-1200 S7-300/400/WinAC
Alarm server
• System diagnostics
• Program_Alarm
• S7-Graph
• ProDiag
Page 34
Data block
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 35
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Online
DB-Editor
Functions
• Re-initialization of actual values with
start values of the DB
• Re-initialization of actual values of multiple DBs
with the snapshot (also entire PLC)
• Redesign of the icons
Overwrite offline values in the ES (snap shot)
Overwrite online values in the PLC
Transfer only of offline values
Benefits
• Quick reset of the application to a defined state
• Quick restoration of the application after upgrade or PLC
replacement
Page 36
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – Online
Monitoring of structures in the block status
Functions
• A new "Monitor value" tab in the inspector window enables
the monitoring of structures on the block as well as their
call environment.
• Context-sensitive selection
• For InOut interconnections, both the transferred and the
returned value are displayed.
Benefits
• Fast troubleshooting when values of a structure variable
change with several accesses per cycle
• Clear representation of actual values of a structure tag
Page 37
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 38
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Innovated cross reference list
Functions
• HMI and PLC accesses at a glance
• New types of cross references (types-instances,…)
• Overlapping accesses on PLC tags
• User input of tags (Go To... functionality)
• Check several tags at the same time
• Support of know how protected blocks
• Several filtering options
Benefits
• Quick analysis of the program structure
• Quick identification of errors
Seite 39
New
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Trace – Repeated measurements/ recording onto a memory card
Objective
• Automated recording without the TIA Portal
• Automated repeated measuring
• Troubleshooting in systems
• Persistent storage of measurements (on memory card)
Configuration and display
• Repeated measuring
• Record N measurements according to trigger conditions
• Reactivate measurement after saving
• Optional: overwrite the oldest measurement
• Up to 1000 measurements
• Webserver S7-1500
• Only measurements stored on the memory card are displayed;
no configuration
• Saving as csv file and display of csv files
• Automatic naming of measurements - including a time stamp
• Measurements will be saved in a separate folder
Page 50
TIA Portal Webserver
RAM
CPU
New
S7-1500 S7-1200 S7-300/400/WinAC
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Trace – Combining measurements
Objective
• Displaying different measurements in a common diagram
Typical applications
• Comparative analysis of repeated measurements (controller optimization)
• Combining simultaneous measurements from different devices (S7-1200, S7-1500, drives)
Page 41
Combining
measurements in PNV
Single measurements Combined measurement
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Trace – Combining measurements - Functionality
Chronological alignment of measurements
• Measurements can be aligned according to the time axis
• Orientation according to trigger pulse, first/last sample
• Orientation according to time stamps
• Additional fine adjustment
Display options (as with a single measurement)
• 16 signals can be displayed at a time
• Signals can be grouped
• Assigned track record or display in a shared diagram
• Display of time stamps or relative to trigger pulse
Page 42
Each measurement can be timed and moved
accordingly.
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Global search
Searching for user texts
• Separate editor for global search
• All of the project data is indexed for quick searches.
Functions
• Start via menu, toolbar, shortcut, context menu
• Textual search with results list, incl. preview of places found
• Structured and sortable
• "Go to“ option form the list to the place found in the editor
• Flexible search request (Infix, Suffix, Wildcards)
• Scope of search can be limited
Scope of search
• PLC (SCL, STL, LAD/FBD, GRAPH, tags)
incl. Failsafe & Trace
• HMI (screens, scripts, recipes, etc.)
Page 43
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Automation Software Updater – Function extensions
Functions
• Corporate Update Server: Selected TIA Portal Updates
can be stored on a local server and then be distributed via
the local network.
• Updates will be distributed through standard Microsoft
server services (IIS, BITS).
Benefits
• Automation Update Server: Central update management
within the company
• Reduction of the needed internet bandwidth
• Enhanced security, as there is no need for the TIA Portal
station to be connected to the internet
Page 44
TIA Portal Engineering Stationen
Siemens Update Server
Corporate Update Server
New
Internet
Intranet
TIA Updater Tool
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Import and export of the TIA Portal settings
Functions
• Manual import and export of the global TIA Portal settings
• Central administration of the global settings
Benefits
• Easy transfer of the global TIA Portal settings between
different installations/PCs
• TIA Portal settings that are valid company-wide can be
easily rolled out to any number of TIA Portal users
• Identical TIA Portal behavior and appearance at all
managed TIA Portal installations
Page 45
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
New help as information system
Functions
• New help system based on HTML
• Expanded search function
• Programming examples for all
PLC applications
• New start page and synchronization
with the online support page
Benefits
• Several search results can be
displayed in separate tabs at the
same time
• Objects can be located more quickly
thanks to device-granular search
options.
Page 46
Search Navigation Content
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal – System functions
Collection of useful functional extensions
Page 47
Archiving and retrieval
• Backup copy or ZIP-archive
• Delete recoverable data
• Add date/time to filename
Grouping of windows
• New button in the status bar
Sorting keyboard shortcuts
• The list of keyboard shortcuts can be sorted
for a better overview (settings keyboard
operation)
New
New
New
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal
Highlights of STEP 7 V14
Page 48
6. System functions
5. Online functions
4. Alarming
3. Language innovations
2. Editor functions
1. Hardware configuration
Monitoring of structures in the block
Re-initialization with start and snapshot
values,
new design of the toolbar in the DB editor
Grouping of devices
Hardware profiles, ….
SCL networks in LAD/FBD
Hide block parameters (LAD/FBD)
SCL regions
Array(*)
Array of multi-instances
Evaluate program changes using checksums
Multi lingual texts on the PLC
Open use of alarm texts
Global search
Innovated information system
Export/import of settings
7. Simulation
Quick PLCSIM startup in
compact mode
Easy device exchange, …
Details
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal - Simulation
S7-PLCSIM - Overview
Functions
• New compact view
• No simulation project needed to start application
• New CPUs:
• S7-1200F incl. F I/Os
• S7-1500 Compact-CPUs
• T-CPU incl. motion functions
• Drag & Drop of hardware modules into the Sim-
table
• Simulation of the decentralized periphery
• Undo/Redo-feature
• Functional extensions for sequences
Page 49
S7-1500 S7-1200 S7-300/400/WinAC
-
Unrestricted © Siemens AG 2016
SIMATIC STEP 7 in the TIA Portal - Simulation
S7-PLCSIM - Sequences
Functions
• Importing CPU traces as a sequence
• Starting a sequence using trigger handling
• Activating/Deactivating of actions
• Delay times for sequences
Benefits
• Simple analysis of parameters in the laboratory
• Simple adjustment of the sequence to fit new
requirements
Page 50
Neu
Neu
S7-1500 S7-1200 S7-300/400/WinAC
-
Unrestricted © Siemens AG 2016
Thank you for your attention!