Standard Assessment Procedure For assessing the energy performance of dwellings (2006) FOR Conversion, Flat 1, 92 Ladbroke Road, Redhill. March 2010 www.SAP-Calculations.co.uk

Upload: lamlien

Post on 03-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Standard Assessment Procedure For assessing the energy performance of dwellings (2006)

FOR

Conversion,

Flat 1, 92 Ladbroke Road,

Redhill.

March 2010

www.SAP-Calculations.co.uk

www.SAP-calculations.co.uk

trading as

ACSystems

Proprietor A.C.Underwood BSc(Hons).,Dip.BSbc.MBEng

8 Beechwood Place Narberth

Pembrokeshire SA67 7EE

Tel : 07870 638476

e-mail : [email protected] web : www.sap-calculations.co.uk

CONTENTS

1. INTRODUCTION 1.1 Generally 1.2 Method of Calculation 1.3 Summary of Calculations

2. OVERVIEW OF MAIN AREAS

2.1 Average ‘U’ Values 2.2 Air Pressure Test 2.3 Primary Heating System 2.4 Secondary Heating System 2.5 Domestic Hot Water 2.6 Ventilation 2.7 Lighting

3. APPENDIX

3.1 Design Input & Results 3.2 Full SAP Calculation Printout 3.3 ‘U’ Value Calculation 3.4 Condensation Risk Analysis

1.0 INTRODUCTION

1.1 Generally The standard Assessment Procedure (SAP) 2005, is adopted by Government as the UK methodology for calculating the energy performance of dwellings. It is used to demonstrate compliance for dwellings with Part L of the Building Regulations (England & Wales) and Part J (Scotland) and to provide energy ratings for dwellings. The calculation is based on the energy balance taking into account a range of factors that contribute to energy efficiency:

• Materials used for construction of the dwelling • Thermal insulation of the building fabric • Ventilation characteristics of the dwelling and ventilation

equipment • efficiency and control of the heating system(s) • solar gains through openings of the dwelling • the fuel used to provide space and water heating, ventilation

and lighting • renewable energy technologies.

Ratings are not affected by the geographical location, so that a given dwelling has the same rating in all parts of the UK. The procedure used for the calculation is based on the BRE Domestic Energy Model, which provides a framework for the calculation of energy use in dwellings. The procedure is consistent with the European standards BS EN 832 and BS EN ISO 13790.

1.2 Method of Calculations Calculations have been provided under SAP 2005 for the conversion of a barn into a dwelling. The work is deemed as a Material Change of Use and the calculations meet the provisions of paragraphs 25-27 of Approved Document L1B. Controlled services are in accordance with paragraphs 31 to 48 of L1b

Retained thermal elements have been renovated and therefore have been upgraded in accordance with paragraphs 56 and 57 of L1B. Compliance with L1B Approved Document 2006 edition is determined with the Building Research Establishment approved program Elmhurst.

1.3 Summary of Calculations

The SAP Rating for this converted property is 66 (Band D) The Environmental Impact Rating is 73 (Band C) C0² Emissions are 2.40 tonnes/yr Therefore, the converted dwelling, Flat 1, 92 Ladbroke Road, Redhill, is compliant with the requirements of SAP 2005.

2.0 OVERVIEW OF MAIN AREAS 2.1 Average U-Values

Walls 0.33 & 0.23 W/m²K Floors 0.16 & 0.22 W/m²K Roofs 0.16 W/m²K Openings 1.80 W/m²K For detailed information refer to appendix

2.2 Air Pressure Test An pressure test is not required - q50 has a design value set at 15.0m³/h/m² @ 50 pa.

2.3 Primary Heating System The design includes electric panel, convector or radiant heaters with programmer and room thermostats.

2.4 Secondary Heating System None

2.5 Domestic Hot Water Dual Immersion heaters in 130ltr cylinder.

2.6 Ventilation Ventilation shall consist of natural ventilation with intermittent extract fans.

2.7 Lighting 100% of artificial lighting within the dwelling are to be low energy.

3.0 APPENDIX

3.1 Design Input & Results

3.2 Full SAP Calculation Printout

3.3 ‘U’ Value Calculation

3.4 Condensation Risk Analysis

DESIGN INPUT & RESULTS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

SUMMARY OF INPUT DATA FOR DWELLING AS BUILT: Page 1 of 2

Region & Orientation Region: TH Thames valley (17), House Orientation: W West

20.84, fraction: 0.288.0 Living Area

74.86 m27.0 Internal Floor Area

26.36 m6.0 Internal Walls Perimeter

5.0 Sunlight/Shade A Average or unknown

4.0 Sheltered Sides

3.0 Date Built

2.0 Number of StoreysGeneral Requirements (new build only)1.0 Property Type G Ground Floor Flat, S Semi Detached

1

2

K 2007 onwards

2.39 m9.0 Average Storey Height

9.1 Conservatory None

Openings Glazing Type Frame or

Door Type

OrientationAir

Gap

UvalueDescription Solar

Trans

Argon

Fill

Area

Double,Low E,Hard Coat PVC 20 mm 1.80 (M)11.0 Windows Front Elevation Yes0.72 West (0°) 5.67

Double,Low E,Hard Coat PVC 20 mm 1.80 (M)Side Elevation Yes0.72 South (90°) 1.05

Double,Low E,Hard Coat PVC 20 mm 1.80 (M)Rear Elevation Yes0.72 East (180°) 8.62

Double,Low E,Hard Coat PVC 20 mm 1.80 (M)Slay Bay

Elevation

Yes0.72 North-West (315°) 0.88

Double,Low E,Hard Coat PVC 20 mm 1.80 (M)Slay Bay

Elevation

Yes0.72 South-West (45°) 0.88

Openings Average: U: 1.80 Uvalue legend: (T) = Uvalue defaulted from SAP Table (M) = Manufacturer supplied

100% 13.0 Draught Proofing

14.0 Thermal Bridging Default - Robust Construction

Thermal Bridges Y 0.080 Description

15.0 Pressure Test (q50)

16.0 Mechanical Ventilation None, Windows open during hot weather: Windows fully open

Cross ventilation possible: Yes

(not tested)

17.1 Lighting Light fittings: 31, L.E.L. fittings: 31, External lights: None

2, 0, 017.0 Fans, Chimneys, Flues

U-value Room in

Roof

TimberDescription Shelter Area Curtain

Walling

New Walling 38.18 No0.23 0.0018.0 Wall Types No

Existing Walling 8.50 No0.33 0.00 No

Walls uvalue average: U: 0.25

Roof Ceiling 8.550.1619.0 Plane Roofs

Roofs uvalue average: U: 0.16

New Ground Floor 29.72 No0.1620.0 Ground Floor Types

Existing Floor 45.66 No0.22

Floors uvalue average: U: 0.19

20.1 Thermal Mass Simple Thermal Mass Parameter calculation: 19.00

Ground Floor Mass: Medium - solid floor

External Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plaster

Separating Wall Mass: High - masonry walls dense plaster

Internal Partition Mass: High - masonry internal walls with dense plaster20.2 Fixed Air Conditioning No

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

DESIGN INPUT & RESULTS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

SUMMARY OF INPUT DATA FOR DWELLING AS BUILT: Page 2 of 2

REA Electric panel, convector or radiant heatersMain Heating21.0

Heating Controls CRD Programmer and room thermostats

Boiler interlock - Yes

Manufacturer & Model Manufacturer's data: TBC, TBC, 100.0%

Manufacturer data: 100.0%MHS Efficiency

Underfloor Heating NoneSecondary Heating NoneSHS Details

21.1

22.0 HEI Independent electric / immersion water heating systems, DualImmersionHot Water Heating

NoneSolar Water Heating

24.0

23.0 Thermal Store NoneHot Water Cylinder Yes, in heated space

25.0

Foam, Thickness: 50 mmInsulation

130.00 litresVolume

Community Heating NoneCHP Unit

7 - Hour Off Peak26.0 Electricity Tariff

None27.0 Photovoltaic Unit

027.1 Micro Wind Turbines Count

27.2 Small-scale Hydro electricity 0.00

None28.0 Special Features

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Full SAP Calculation Printout

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 1

SAP2005 - 9.81 input data (DesignData) -

Regs Region: EnglandCalculation Type: ConversionRegion: TH Thames valley (17)Orientation: W WestPropType: G Ground Floor Flat, S Semi DetachedStoreys: 1Property Age Band: KSheltered Sides: 2Sunlight Shade: A Average or unknownWall Perimeter: 26.36 mFloor Area: 74.86 m2Living Floor Area: 20.84 m2, fraction:0.00Storey Height: 2.39 mConservatory: NoneDoorsWindows Front Elevation: Double,Low E,Hard Coat, PVC, 20 mm, West (0°), uvalue: 1.80 (M), area: 5.67 m2, argon: Yes, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 20 mm, South (90°), uvalue: 1.80 (M), area: 1.05 m2, argon: Yes, solar trans: 0.72 Rear Elevation: Double,Low E,Hard Coat, PVC, 20 mm, East (180°), uvalue: 1.80 (M), area: 8.62 m2, argon: Yes, solar trans: 0.72 Slay Bay Elevation: Double,Low E,Hard Coat, PVC, 20 mm, North-West (315°), uvalue: 1.80 (M), area: 0.88 m2, argon: Yes, solar trans: 0.72 Slay Bay Elevation: Double,Low E,Hard Coat, PVC, 20 mm, South-West (45°), uvalue: 1.80 (M), area: 0.88 m2, argon: Yes, solar trans: 0.72Draught Lobby: YesDraught Proofing: 100%Roof LightsPressure Test: (not tested)Mechanical Ventilation: None, Windows open during hot weather: Windows fully open Cross ventilation possible: YesFans, Chimneys, Flues: 2, 0, 0Lighting: Light fittings: 31, L.E.L. fittings: 31, External lights: NoneMain Wall Type: U: 0.23 A: 38.18 m2Extented Wall Types: U: 0.33 A: 8.50 m2Timber Frame Wall Area: 0Roof Ceiling U: 0.16 A: 8.55 m2Main Floor Type: U: 0.16 A: 29.72 m2Existing Floor U: 0.22 A: 45.66 m2Thermal Mass: Simple Thermal Mass Parameter calculation: 19.00 Ground Floor Mass: Medium - solid floor External Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plaster Separating Wall Mass: High - masonry walls dense plaster Internal Partition Mass: High - masonry internal walls with dense plasterTimber Floor: No Timber FloorFixed Air Conditioning: NoMain Heating: REA Electric panel, convector or radiant heatersMain Heating Manufacturer: Manufacturer's data: TBC, TBC, 100.0%Heating Controls: CRD Programmer and room thermostats Boiler interlock - Yes

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 2

Underfloor Heating: NoneSecondary Heating: NoneManufacturer:Thermal Store: NoneHot Water Heating: HEI Independent electric / immersion water heating systems, DualImmersionSolar Water Heating: NoneThermal Store: NoneHot Water Cylinder: Yes, in heated spaceHot Water Cylinder Insulation: Foam, Thickness: 50 mmHot Water Cylinder Volume: 130.00 litresCommunity Heating: NoneCHP Unit:Electricity Tariff: 7 - Hour Off PeakThermal Bridges: DefaultRobustConstr, Thermal bridging factor y = 0.08PV Cells: NoneEnergy Saved:Energy Used:Terrain Type: UrbanNumber of Wind Turbines: 0

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 3

SAP calculation (Conversion)

1. Overall dwelling dimensionsGround floor 74.860 * 2.390 178.9154Total floor area 74.860 (5)Total house volume 178.9154 (6)

2. Ventilation rateNumber of chimneys 0 * 40 0 (7)Number of flues 0 * 20 0 (8)Number of fans 2 * 10 20 (9)Flueless gas fire 0 * 40 0 (9a)Infiltration 0.1118 (10)

Number of storeys 1 (11)Additional infiltration 0.0000 (12)Structural infiltration 0.3500 (13)Wooden floor infiltration 0.0000 (14)Draught lobby infiltration 0.0000 (15)Percentage windows draught proofed 100.0000 (16)Window infiltration 0.0500 (17)Infiltration rate 0.5118 (18,19)

Sides sheltered 2 (20)Shelter factor 0.8500 (21)Adjusted infiltration rate 0.4350 (22)Air change natural ventilation 0.5946 (24)Effective air change rate 0.5946 (25)

3. Heat losses and heat loss parameter

Windows Front Elevation 5.6700 * (1.80) 1.68 9.5205 (27)Windows Side Elevation 1.0500 * (1.80) 1.68 1.7631 (27)Windows Rear Elevation 8.6200 * (1.80) 1.68 14.4739 (27)Windows Slay Bay Elevation 0.8800 * (1.80) 1.68 1.4776 (27)Windows Slay Bay Elevation 0.8800 * (1.80) 1.68 1.4776 (27)

New Ground Floor 29.7200 * 0.16 4.7552 (28)Existing Floor 45.6600 * 0.22 10.0452 (28)

New Walling 38.1800 * 0.23 8.7814 (29)Existing Walling 8.5000 * 0.33 2.8050 (29)

Roof Ceiling 8.5500 * 0.16 1.3680 (30)

Total area of elements 147.7100 (32)Fabric heat loss 56.4675 (33)Appendix K: Thermal bridging 0.0800 (y)Effect of thermal bridges 11.8168 (34)Total fabric heat loss 68.2843 (35)Ventilation heat loss 35.1076 (36)Heat loss coefficient 103.3919 (37)Heat loss parameter (HLP) 1.3811 (38)

4. Water heating energy requirementsEnergy content of heated water 1778.3727 (39)Distribution loss 313.8305 (40)Cylinder volume 130.0000 (43)Cylinder loss factor (kWh/litre/day) 0.0152 (44)Volume factor from Table 2a 0.9737 (44a)Temperature factor from Table 2b 0.6000 (44b)Energy lost from water storage, kWh/year 420.9400 (45)

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 4

Energy lost from cylinder in kWh/year 420.9400 (47)Primary circuit loss 0.0000 (48)Output from water heater 2513.1432 (51)Gains from water heating 1032.4096 (52)

5. Internal gainsLighting, appliances, cooking and metabolic (Table 5) 454.8672 (53)Reduction of internal gains due to LE lighting (Appendix L)Correction factor for low-energy outlets 0.5000 (C1)Window 1 0.9 * 5.670 * 0.80 * 0.7 * 0.83 / 74.860 0.0317Window 2 0.9 * 1.050 * 0.80 * 0.7 * 0.83 / 74.860 0.0059Window 3 0.9 * 8.620 * 0.80 * 0.7 * 0.83 / 74.860 0.0482Window 4 0.9 * 0.880 * 0.80 * 0.7 * 0.83 / 74.860 0.0049Window 5 0.9 * 0.880 * 0.80 * 0.7 * 0.83 / 74.860 0.0049Ratio of glass area to floor area 0.0956 (GL)Correction factor for daylighting 0.9600 (C2)Annual energy used for lighting in the house 334.1750 (EL)Reduction in lighting use due to low energy lights 334.1750 (deltaEL)Low energy lighting -50.1263 (53a)Additional gains (Table 5a) 0.0000 (53b)Water heating 117.8550 (54)Total internal gains 522.5959 (55)

6. Solar gains Area Flux g FF Access Gains (m2) Factor (W)Windows 'W ' 0.9 * 5.6700 * 48 * 0.72 * 0.7000 * 0.77 95.0579 (62)Windows (1) 'S ' 0.9 * 1.0500 * 72 * 0.72 * 0.7000 * 0.77 26.4050 (60)Windows (2) 'E ' 0.9 * 8.6200 * 48 * 0.72 * 0.7000 * 0.77 144.5148 (58)Windows (3) 'NW' 0.9 * 0.8800 * 34 * 0.72 * 0.7000 * 0.77 10.4502 (63)Windows (4) 'SW' 0.9 * 0.8800 * 64 * 0.72 * 0.7000 * 0.77 19.6710 (61)Total solar gains 296.0988 (65)Total gains, W 818.6948 (66)Gains/loss ratio (GLR) 7.9184 (67)Utilisation factor 0.8970 (68)Useful gains, W 734.3835 (69)

7. Mean internal temperatureMean internal temperature of living zone (heating type = 1) 18.8800 (70)Temperature addjustment 0.0000 (71)Adjustment for gains 0.6206 (72)Adjusted room temperature 19.5006 (73)Temperature difference between zones 1.8796 (74)Living area fraction 0.2784 (75)Rest of house floor fraction 0.7216 (76)Mean internal temperature 18.1442 (77)

8. Degree-daysTemperature raise from gains 7.1029 (78)Base temperature 11.0413 (79)Degree days 1148.2669 (80)

9a. Energy requirements - individual heating systems, including Micro CHPSpace heating requirement (useful) 2849.3154 (81)Test Method :Model name : TBCManufacturer: TBCMHS efficiency 100.0000Main system efficiency 100.0000 (83)Space heating fuel - main HS 2849.3154 (85)Space heating fuel - secondary HS 0.0000 (85a)Efficiency of water heater 100.0000 (86)Energy required for water heating 2513.1432Energy used for water heating 2513.1432 (86a)Electricity for pumps and fans 0.0000 (87)

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 5

Electricity for pumps and fans - total 0.0000Electricity for lighting (100% fixed LEL) 334.1750 (87g)

10a. Fuel costs - individual heating systemsMHS heating cost 2849.3154 * 7.6500 217.9726 (88)SHS heating cost 0.0000 * 0.0000 0.0000 (89)On-peak fraction 0.1376 (90)Off-peak fraction 0.8624 (90a)On-peak cost 345.7658 * 7.6500 26.4511 (91)Off-peak cost 2167.3774 * 2.9400 63.7209 (91a)Pump/fan energy 0.0000 * 7.6500 0.0000 (92)Lighting energy 334.1750 * 7.6500 25.5644 (93)Additional standing charges 20.0000 (94)-----------------------------------------------------------------------------Total energy cost 353.7090 (97)Total energy cost using Sedbuk db prices 583.0513

11a. SAP ratingEnergy cost deflator 0.9100 (98)Energy cost factor (ECF) 2.4351 (99)ECF unrounded = 2.4351342252437SAP value 66.0055 (99a)SAP value unrounded = 66.005526215598SAP Energy rating 66 (100)SAP Energy rating band D

12a. Carbon dioxide emissionsMHS heating CO2 - box (85) 2849.3154 * 0.4220 1202.4111 (101)WHS heating CO2 - box (86a) 2513.1432 * 0.4220 1060.5464 (103)Space and water heating CO2 2262.9575 (107)Pumps and fans CO2 - box (87) 0.0000 * 0.4220 0.0000 (108)Electricity for lighting 334.1750 * 0.4220 141.0219 (109)Total CO2 emissions in kg/year 2403.9794 (112)CO2 emissions per m? 32.1130Dwelling's Carbon Factor 20.0566 (CF)EI value 73.1242 (113a)EI rating 73 (114)EI band C

13a. Primary energyMHS heating P.E. - box (85) 2849.3154 * 2.8000 7978.0831WHS heating P.E. - box (86a) 2513.1432 * 2.8000 7036.8010Space and water heating P.E. 15014.8840 (107)Pumps and fans P.E. - box (87) 0.0000 * 2.8000 0.0000 (108)Electricity for lighting 334.1750 * 2.8000 935.6901 (109)Primary energy kWh/year 15950.5742 (112)Primary energy kWh/m2/year 213.0721

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 6

Recommendation Level E

Recommendation result : AlreadyInstalledE Recommendation text : Low energy lighting recommendation

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 7

Recommendation Level N

Recommendation result : NotApplicableN Recommendation text : Solar panel recommendation

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 8

Recommendation Level U

Recommendation result : NotApplicableU Recommendation text : PV Cells recommendation

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 9

Recommendation Level

V Wind turbine : blade diameter 1.75 m Recommendation result : RecommendedV Recommendation no : 44V Recommendation text : Wind turbine CO2 emissions : 2377.220 (change = -26.759) Total energy cost (97) : 350.381 (change = 3.328) Total energy cost (Sedbuk) : 577.527 (change = -5.524) SAP rating : 66 (value = 66.358) EI rating : 73 (value = 73.423)V Recommendation : SAP change (66.358 - 66.006), increase = 0.352 EffectTooSmall

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 10

Recommendation Total

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 11

SAP2005 - 9.81 input data (DesignData) -

Regs Region: EnglandCalculation Type: ConversionRegion: TH Thames valley (17)Orientation: W WestPropType: G Ground Floor Flat, S Semi DetachedStoreys: 1Property Age Band: KSheltered Sides: 2Sunlight Shade: A Average or unknownWall Perimeter: 26.36 mFloor Area: 74.86 m2Living Floor Area: 20.84 m2, fraction:0.28Storey Height: 2.39 mConservatory: NoneDoorsWindows Front Elevation: Double,Low E,Hard Coat, PVC, 20 mm, West (0°), uvalue: 1.80 (M), area: 5.67 m2, argon: Yes, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 20 mm, South (90°), uvalue: 1.80 (M), area: 1.05 m2, argon: Yes, solar trans: 0.72 Rear Elevation: Double,Low E,Hard Coat, PVC, 20 mm, East (180°), uvalue: 1.80 (M), area: 8.62 m2, argon: Yes, solar trans: 0.72 Slay Bay Elevation: Double,Low E,Hard Coat, PVC, 20 mm, North-West (315°), uvalue: 1.80 (M), area: 0.88 m2, argon: Yes, solar trans: 0.72 Slay Bay Elevation: Double,Low E,Hard Coat, PVC, 20 mm, South-West (45°), uvalue: 1.80 (M), area: 0.88 m2, argon: Yes, solar trans: 0.72Draught Lobby: YesDraught Proofing: 100%Roof LightsPressure Test: (not tested)Mechanical Ventilation: None, Windows open during hot weather: Windows fully open Cross ventilation possible: YesFans, Chimneys, Flues: 2, 0, 0Lighting: Light fittings: 31, L.E.L. fittings: 31, External lights: NoneMain Wall Type: U: 0.23 A: 38.18 m2Extented Wall Types: U: 0.33 A: 8.50 m2Timber Frame Wall Area: 0Roof Ceiling U: 0.16 A: 8.55 m2Main Floor Type: U: 0.16 A: 29.72 m2Existing Floor U: 0.22 A: 45.66 m2Thermal Mass: Simple Thermal Mass Parameter calculation: 19.00 Ground Floor Mass: Medium - solid floor External Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plaster Separating Wall Mass: High - masonry walls dense plaster Internal Partition Mass: High - masonry internal walls with dense plasterTimber Floor: No Timber FloorFixed Air Conditioning: NoMain Heating: REA Electric panel, convector or radiant heatersMain Heating Manufacturer: Manufacturer's data: TBC, TBC, 100.0%Heating Controls: CRD Programmer and room thermostats Boiler interlock - YesUnderfloor Heating: NoneSecondary Heating: NoneManufacturer:Thermal Store: NoneHot Water Heating: HEI Independent electric / immersion water heating systems, DualImmersionSolar Water Heating: NoneThermal Store: NoneHot Water Cylinder: Yes, in heated spaceHot Water Cylinder Insulation: Foam, Thickness: 50 mmHot Water Cylinder Volume: 130.00 litresCommunity Heating: NoneCHP Unit:Electricity Tariff: 7 - Hour Off PeakThermal Bridges: DefaultRobustConstr, Thermal bridging factor y = 0.08PV Cells: NoneEnergy Saved:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 12

Energy Used:Terrain Type: UrbanNumber of Wind Turbines: 0

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

CALCULATION DETAILS for survey reference no 'A998-0001-09-140-1' Page: 13

Recommendations calculation (Conversion)

No improvements selected

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

UVALUE CALCULATION

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Floor 1 - Slab on the ground floor

Floor Type: Slab on ground

Area = 74.86 m², Perimeter = 26.36 m, Wall thickness = 300 mm, Soil: Unknown

Horizontal edge insulation: none

Vertical edge insulation: Width D = 75.0 mm, Thickness dn = 25.0 mm, Lambda = 0.040

Layer FractionRlThicknessDescription

External surface 0.040

Layer1 Celotex

Main construction 100 mm 0.023 100.00 %4.348

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer2 Screed

Main construction 65 mm 0.410 100.00 %0.159

Internal surface 0.170

Upper limit = 4.506 m²K/W Lower limit = 4.506 m²K/W Average = 4.506 m²K/WTotal resistance:

U-value (unrounded) = 0.0000 W/m²K

Slab on Ground floor corrections:

Horizontal delta Psi = -0.0005 Vertical delta Psi = -0.0011 B' = 5.6798 Delta U = -0.00055

U-value: 0.16 W/m²KTotal thickness: 165 mm

Building Element Floor 2 - Slab on the ground floor

Floor Type: Slab on ground

Area = 45.66 m², Perimeter = 6.23 m, Wall thickness = 300 mm, Soil: Unknown

Horizontal edge insulation: none

Vertical edge insulation: none

Layer FractionRlThicknessDescription

External surface 0.040

Layer1 Celotex

Main construction 25 mm 0.023 100.00 %1.087

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer2 Screed

Main construction 60 mm 0.410 100.00 %0.146

Internal surface 0.170

Upper limit = 1.233 m²K/W Lower limit = 1.233 m²K/W Average = 1.233 m²K/WTotal resistance:

U-value (unrounded) = 0.0000 W/m²K

Slab on Ground floor corrections:

Horizontal delta Psi = -0.0037 Vertical delta Psi = -0.0060 B' = 14.6581 Delta U = -0.00133

U-value: 0.22 W/m²KTotal thickness: 85 mm

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

UVALUE CALCULATION

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Roof Plane 1 - Pitched roof - insulated ceiling

Roof Type: Pitched Roof, insulated flat ceiling

Layer FractionRlThicknessDescription

External surface 0.040

Layer1 Mineral wool

Main construction 150 mm 0.040 100.00 %3.750

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer2 Mineral wool

Main construction 100 mm 0.040 91.67 %2.500

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Bridging - Wood 100 mm 0.130 8.33 %0.000

Layer3 Plasterboard, standard

Main construction 13 mm 0.210 100.00 %0.060

Internal surface 0.100

Upper limit = 6.258 m²K/W Lower limit = 6.055 m²K/W Average = 6.157 m²K/WTotal resistance:

U-value (unrounded) = 0.1624 W/m²K

Unheated space: None

U-value: 0.16 W/m²KTotal thickness: 263 mm

Building Element Wall Main - Masonry-full cavity fill: slabs

Layer FractionRlThicknessDescription

External surface 0.040

Layer1 Brick, outer leaf

Main construction 105 mm 0.770 82.81 %0.136

Bridging - Mortar 105 mm 0.941 17.19 %0.000

Layer2 High E Cavity

Main construction 40 mm 0.060 100.00 %0.665

Layer3 Celotex

Main construction 60 mm 0.023 100.00 %2.609

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer4 Celcon Solar - Normal - Trad joint 10mm

Main construction 100 mm 0.110 93.18 %0.909

Bridging - Mortar 100 mm 0.880 6.82 %0.000

Layer5 Plaster, dense

Main construction 15 mm 0.570 100.00 %0.026

Internal surface 0.130

Upper limit = 4.446 m²K/W Lower limit = 4.217 m²K/W Average = 4.331 m²K/WTotal resistance:

U-value (unrounded) = 0.2309 W/m²K

Unheated space: None

U-value: 0.23 W/m²KTotal thickness: 320 mm

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

UVALUE CALCULATION

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Wall Type 1 - Masonry-solid wall

Layer FractionRlThicknessDescription

External surface 0.040

Layer1 Brick, outer leaf

Main construction 220 mm 0.770 82.81 %0.286

Bridging - Mortar 220 mm 0.941 17.19 %0.000

Layer2 Gyproc Thermaline Super 65mm

Main construction 65 mm 0.025 100.00 %2.550

Corrections - Air Gap: Level 0, Fasteners: None or plastic

Internal surface 0.130

Upper limit = 2.997 m²K/W Lower limit = 2.995 m²K/W Average = 2.996 m²K/WTotal resistance:

U-value (unrounded) = 0.3338 W/m²K

Unheated space: None

U-value: 0.33 W/m²KTotal thickness: 285 mm

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 1

CONDENSATION RISK ANALYSIS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Wall Main - Masonry-full cavity fill: slabs

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Vapour

resistance

GN.s/kg

Vapour

resistivity

GN.s/kg.m

Thermal

resistance

m2.K/W

Thermal

conduct.

W/m.K

Width

mm

Layer Cumulative

thermal

resistancem2.K/W

Cumulative

vapour

resistanceGN.s/kg

Table of layers:

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.286 0.326 11.00220.0 0.770 50.0 11.00

2. Gyproc Thermaline Super 65mm 2.550 2.876 17.5065.0 0.000 100.0 6.50

Internal surface 0.130 2.876 17.50- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 1.087 1.127 1,084.3325.0 0.023 43,373.0 1,084.33

2. Screed 0.146 1.273 1,084.3360.0 0.410 0.000 0.000

Internal surface 0.170 1.273 1,084.33- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.136 0.176 5.25105.0 0.770 50.0 5.25

2. High E Cavity 0.665 0.841 5.2540.0 0.000 0.000 0.000

3. Celotex 2.609 3.450 2,607.6360.0 0.023 43,373.0 2,602.38

4. Celcon Solar - Normal - Trad joint 10mm 0.909 4.359 2,613.63100.0 0.110 60.0 6.00

5. Plaster, dense 0.026 4.385 2,614.5315.0 0.570 60.0 0.90

Internal surface 0.130 4.385 2,614.53- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.30

2. Screed 0.159 4.546 4,337.3065.0 0.410 0.000 0.000

Internal surface 0.170 4.546 4,337.30- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.50

2. Mineral wool 2.500 6.290 2.50100.0 0.040 10.0 1.00

3. Plasterboard, standard 0.060 6.350 3.0612.5 0.210 45.0 0.56

Internal surface 0.100 6.350 3.06- 0.000 0.000 0.000

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 2

Satur.

vapour

pressurePa

Vapour

pressure

Pa

Interface

temp.

°C

Interface - between layers

Vapour pressure table:

Cond.

rate

60 daysg/m2.h

Cond.

risk

Y/N

Cond.

rate

g/m2.h

Dew

point

°C

External surface 5.00 828.3 871.9 0.00 No0.00 4.27

1. External surface / Brick, outer leaf 5.09 828.3 877.3 0.00 No0.00 4.27

2. Brick, outer leaf / High E Cavity 5.39 828.8 895.9 0.00 No0.00 4.28

3. High E Cavity / Celotex 6.86 828.8 992.0 0.00 No0.00 4.28

4. Celotex / Celcon Solar - Normal - Trad joint 10mm 12.64 1 107.1 1 462.1 0.00 No0.00 8.47

5. Celcon Solar - Normal - Trad joint 10mm / Plaster, dense 14.65 1 107.8 1 666.8 0.00 No0.00 8.48

6. Plaster, dense / Internal surface 14.71 1 107.9 1 673.1 0.00 No0.00 8.48

Internal surface 15.00 1 107.9 1 673.1 0.00 No0.00 8.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

VPressure SatVPressure

Interface

Vap

ou

r p

ressu

re (

Pa

)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Temperature DewPoint

Interface

Tem

pera

ture

(P

a)

Interface temperature / Dew point graphical representation:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 3

CONDENSATION RISK ANALYSIS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Floor 1 - Slab on the ground floor

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Vapour

resistance

GN.s/kg

Vapour

resistivity

GN.s/kg.m

Thermal

resistance

m2.K/W

Thermal

conduct.

W/m.K

Width

mm

Layer Cumulative

thermal

resistancem2.K/W

Cumulative

vapour

resistanceGN.s/kg

Table of layers:

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.286 0.326 11.00220.0 0.770 50.0 11.00

2. Gyproc Thermaline Super 65mm 2.550 2.876 17.5065.0 0.000 100.0 6.50

Internal surface 0.130 2.876 17.50- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 1.087 1.127 1,084.3325.0 0.023 43,373.0 1,084.33

2. Screed 0.146 1.273 1,084.3360.0 0.410 0.000 0.000

Internal surface 0.170 1.273 1,084.33- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.136 0.176 5.25105.0 0.770 50.0 5.25

2. High E Cavity 0.665 0.841 5.2540.0 0.000 0.000 0.000

3. Celotex 2.609 3.450 2,607.6360.0 0.023 43,373.0 2,602.38

4. Celcon Solar - Normal - Trad joint 10mm 0.909 4.359 2,613.63100.0 0.110 60.0 6.00

5. Plaster, dense 0.026 4.385 2,614.5315.0 0.570 60.0 0.90

Internal surface 0.130 4.385 2,614.53- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.30

2. Screed 0.159 4.546 4,337.3065.0 0.410 0.000 0.000

Internal surface 0.170 4.546 4,337.30- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.50

2. Mineral wool 2.500 6.290 2.50100.0 0.040 10.0 1.00

3. Plasterboard, standard 0.060 6.350 3.0612.5 0.210 45.0 0.56

Internal surface 0.100 6.350 3.06- 0.000 0.000 0.000

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 4

Satur.

vapour

pressurePa

Vapour

pressure

Pa

Interface

temp.

°C

Interface - between layers

Vapour pressure table:

Cond.

rate

60 daysg/m2.h

Cond.

risk

Y/N

Cond.

rate

g/m2.h

Dew

point

°C

External surface 5.00 828.3 871.9 0.00 No0.00 4.27

1. External surface / Celotex 5.08 828.3 877.0 0.00 No0.00 4.27

2. Celotex / Screed 14.30 1 107.9 1 629.5 0.00 No0.00 8.48

3. Screed / Internal surface 14.64 1 107.9 1 665.3 0.00 No0.00 8.48

Internal surface 15.00 1 107.9 1 665.3 0.00 No0.00 8.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

VPressure SatVPressure

Interface

Vap

ou

r p

ressu

re (

Pa

)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Temperature DewPoint

Interface

Tem

pera

ture

(P

a)

Interface temperature / Dew point graphical representation:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 5

CONDENSATION RISK ANALYSIS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Wall Type 1 - Masonry-solid wall

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Vapour

resistance

GN.s/kg

Vapour

resistivity

GN.s/kg.m

Thermal

resistance

m2.K/W

Thermal

conduct.

W/m.K

Width

mm

Layer Cumulative

thermal

resistancem2.K/W

Cumulative

vapour

resistanceGN.s/kg

Table of layers:

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.286 0.326 11.00220.0 0.770 50.0 11.00

2. Gyproc Thermaline Super 65mm 2.550 2.876 17.5065.0 0.000 100.0 6.50

Internal surface 0.130 2.876 17.50- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 1.087 1.127 1,084.3325.0 0.023 43,373.0 1,084.33

2. Screed 0.146 1.273 1,084.3360.0 0.410 0.000 0.000

Internal surface 0.170 1.273 1,084.33- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.136 0.176 5.25105.0 0.770 50.0 5.25

2. High E Cavity 0.665 0.841 5.2540.0 0.000 0.000 0.000

3. Celotex 2.609 3.450 2,607.6360.0 0.023 43,373.0 2,602.38

4. Celcon Solar - Normal - Trad joint 10mm 0.909 4.359 2,613.63100.0 0.110 60.0 6.00

5. Plaster, dense 0.026 4.385 2,614.5315.0 0.570 60.0 0.90

Internal surface 0.130 4.385 2,614.53- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.30

2. Screed 0.159 4.546 4,337.3065.0 0.410 0.000 0.000

Internal surface 0.170 4.546 4,337.30- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.50

2. Mineral wool 2.500 6.290 2.50100.0 0.040 10.0 1.00

3. Plasterboard, standard 0.060 6.350 3.0612.5 0.210 45.0 0.56

Internal surface 0.100 6.350 3.06- 0.000 0.000 0.000

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 6

Satur.

vapour

pressurePa

Vapour

pressure

Pa

Interface

temp.

°C

Interface - between layers

Vapour pressure table:

Cond.

rate

60 daysg/m2.h

Cond.

risk

Y/N

Cond.

rate

g/m2.h

Dew

point

°C

External surface 5.00 828.3 871.9 0.00 No0.00 4.27

1. External surface / Brick, outer leaf 5.13 828.3 880.0 0.00 No0.00 4.27

2. Brick, outer leaf / Gyproc Thermaline Super 65mm 6.08 940.1 940.1 0.06 Yes81.16 6.08

3. Gyproc Thermaline Super 65mm / Internal surface 14.57 1 107.9 1 657.5 0.00 No0.00 8.48

Internal surface 15.00 1 107.9 1 657.5 0.00 No0.00 8.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

VPressure SatVPressure

Interface

Vap

ou

r p

ressu

re (

Pa

)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Temperature DewPoint

Interface

Tem

pera

ture

(P

a)

Interface temperature / Dew point graphical representation:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 7

CONDENSATION RISK ANALYSIS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Floor 2 - Slab on the ground floor

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Vapour

resistance

GN.s/kg

Vapour

resistivity

GN.s/kg.m

Thermal

resistance

m2.K/W

Thermal

conduct.

W/m.K

Width

mm

Layer Cumulative

thermal

resistancem2.K/W

Cumulative

vapour

resistanceGN.s/kg

Table of layers:

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.286 0.326 11.00220.0 0.770 50.0 11.00

2. Gyproc Thermaline Super 65mm 2.550 2.876 17.5065.0 0.000 100.0 6.50

Internal surface 0.130 2.876 17.50- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 1.087 1.127 1,084.3325.0 0.023 43,373.0 1,084.33

2. Screed 0.146 1.273 1,084.3360.0 0.410 0.000 0.000

Internal surface 0.170 1.273 1,084.33- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.136 0.176 5.25105.0 0.770 50.0 5.25

2. High E Cavity 0.665 0.841 5.2540.0 0.000 0.000 0.000

3. Celotex 2.609 3.450 2,607.6360.0 0.023 43,373.0 2,602.38

4. Celcon Solar - Normal - Trad joint 10mm 0.909 4.359 2,613.63100.0 0.110 60.0 6.00

5. Plaster, dense 0.026 4.385 2,614.5315.0 0.570 60.0 0.90

Internal surface 0.130 4.385 2,614.53- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.30

2. Screed 0.159 4.546 4,337.3065.0 0.410 0.000 0.000

Internal surface 0.170 4.546 4,337.30- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.50

2. Mineral wool 2.500 6.290 2.50100.0 0.040 10.0 1.00

3. Plasterboard, standard 0.060 6.350 3.0612.5 0.210 45.0 0.56

Internal surface 0.100 6.350 3.06- 0.000 0.000 0.000

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 8

Satur.

vapour

pressurePa

Vapour

pressure

Pa

Interface

temp.

°C

Interface - between layers

Vapour pressure table:

Cond.

rate

60 daysg/m2.h

Cond.

risk

Y/N

Cond.

rate

g/m2.h

Dew

point

°C

External surface 5.00 828.3 871.9 0.00 No0.00 4.27

1. External surface / Celotex 5.28 828.3 888.9 0.00 No0.00 4.27

2. Celotex / Screed 12.81 1 107.9 1 478.3 0.00 No0.00 8.48

3. Screed / Internal surface 13.82 1 107.9 1 579.4 0.00 No0.00 8.48

Internal surface 15.00 1 107.9 1 579.4 0.00 No0.00 8.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

VPressure SatVPressure

Interface

Vap

ou

r p

ressu

re (

Pa

)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Temperature DewPoint

Interface

Tem

pera

ture

(P

a)

Interface temperature / Dew point graphical representation:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 9

CONDENSATION RISK ANALYSIS

DER: 0.00TER: 0.00

Prop Type Ref:

Issued on: 17.March.2010

Flat 1, 92, Ladbroke Road, REDHILL, RH1 1LB

A998-0001-09-140-1

Property:

Users Ref:

0.00ZC:0Ene1:

SAP Energy Cost: CO2 Emissions: 2.40 t/yearEnergy used: 213 kWh/m2/year

SAP Rating: £353.71EI Rating:

66 D

73 C

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: Conversion

Software Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

A998-0001, Andrew Underwood, Tel: 07870 638476Surveyor:

8 Beechwood Place, Narberth, Pembrokeshire, SA67 7EEAddress:

Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Roof Plane 1 - Pitched roof - insulated ceiling

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Vapour

resistance

GN.s/kg

Vapour

resistivity

GN.s/kg.m

Thermal

resistance

m2.K/W

Thermal

conduct.

W/m.K

Width

mm

Layer Cumulative

thermal

resistancem2.K/W

Cumulative

vapour

resistanceGN.s/kg

Table of layers:

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.286 0.326 11.00220.0 0.770 50.0 11.00

2. Gyproc Thermaline Super 65mm 2.550 2.876 17.5065.0 0.000 100.0 6.50

Internal surface 0.130 2.876 17.50- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 1.087 1.127 1,084.3325.0 0.023 43,373.0 1,084.33

2. Screed 0.146 1.273 1,084.3360.0 0.410 0.000 0.000

Internal surface 0.170 1.273 1,084.33- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Brick, outer leaf 0.136 0.176 5.25105.0 0.770 50.0 5.25

2. High E Cavity 0.665 0.841 5.2540.0 0.000 0.000 0.000

3. Celotex 2.609 3.450 2,607.6360.0 0.023 43,373.0 2,602.38

4. Celcon Solar - Normal - Trad joint 10mm 0.909 4.359 2,613.63100.0 0.110 60.0 6.00

5. Plaster, dense 0.026 4.385 2,614.5315.0 0.570 60.0 0.90

Internal surface 0.130 4.385 2,614.53- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.30

2. Screed 0.159 4.546 4,337.3065.0 0.410 0.000 0.000

Internal surface 0.170 4.546 4,337.30- 0.000 0.000 0.000

External surface 0.040 0.040 0.00- 0.000 0.000 0.000

1. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.50

2. Mineral wool 2.500 6.290 2.50100.0 0.040 10.0 1.00

3. Plasterboard, standard 0.060 6.350 3.0612.5 0.210 45.0 0.56

Internal surface 0.100 6.350 3.06- 0.000 0.000 0.000

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page: 10

Satur.

vapour

pressurePa

Vapour

pressure

Pa

Interface

temp.

°C

Interface - between layers

Vapour pressure table:

Cond.

rate

60 daysg/m2.h

Cond.

risk

Y/N

Cond.

rate

g/m2.h

Dew

point

°C

External surface 5.00 828.3 871.9 0.00 No0.00 4.27

1. External surface / Mineral wool 5.06 828.3 875.6 0.00 No0.00 4.27

2. Mineral wool / Mineral wool 10.88 965.2 1 301.3 0.00 No0.00 6.47

3. Mineral wool / Plasterboard, standard 14.75 1 056.5 1 677.5 0.00 No0.00 7.78

4. Plasterboard, standard / Internal surface 14.84 1 107.9 1 687.5 0.00 No0.00 8.48

Internal surface 15.00 1 107.9 1 687.5 0.00 No0.00 8.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

VPressure SatVPressure

Interface

Vap

ou

r p

ressu

re (

Pa

)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Temperature DewPoint

Interface

Tem

pera

ture

(P

a)

Interface temperature / Dew point graphical representation:

ã Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB