staad pro book.docx

Upload: rudey18

Post on 14-Apr-2018

519 views

Category:

Documents


30 download

TRANSCRIPT

  • 7/27/2019 Staad Pro Book.docx

    1/26

    STAAD.Pro

    STructuralAnalysis

    AndDesign

    Program

  • 7/27/2019 Staad Pro Book.docx

    2/26

    GENERAL DESCRIPTION

    The STAAD.Pro Graphical User Interface (GUI) is normally used to create all input specifications

    and all output reports and displays (See the Graphical Environment manual). These structural modeling

    and analysis input specifications are stored in a text file with extension .STD. When the GUI does a File

    Open to start a session with an existing model, it gets all of its information from the STD file. A user mayedit/create this STD file and have the GUI and the analysis engine both reflect the changes.

    The STD file is processed by the STAAD analysis engine to produce results that are stored in several

    files with extensions such as ANL, BMD, TMH, etc. The ANL text file contains the printable output as

    created by the specifications in this manual. The other files contain the results (displacements,

    member/element forces, mode shapes, section forces/moments/displacements, etc.) that are used by

    the GUI in post processing mode.

    Input Generation

    The GUI (or user) communicates with the STAAD analysis engine through the STD input file. That inputfile is a text file consisting of a series of commands which are executed sequentially. The commands

    contain either instructions or data pertaining to analysis and/or design.

    Types of Structures

    A STRUCTURE can be defined as an assemblage of elements. STAAD is capable of analyzing and

    designing structures consisting of frame, plate/shell and solid elements. Almost any type of structure

    can be analyzed by STAAD.

    A SPACE structure, which is a three dimensional framed structure with loads applied in any plane, is the

    most general.

    A PLANE structure is bound by a global X-Y coordinate system with loads in the same plane.

    A TRUSS structure consists of truss members who can have only axial member forces and no bending in

    the members.

    A FLOOR structure is a two or three dimensional structure having no horizontal (global X or Z)

    movement of the structure [FX, FZ & MY restrained at every joint]. The floor framing (in global X-Z plane)

    of a building is an ideal example of a FLOOR structure. Columns can also be modeled with the floor in a

    FLOOR structure as long as the structure has no horizontal loading. If there is any horizontal load, it must

    be analyzed as a SPACE structure.

    Specification of the correct structure type reduces the number of equations to be solved during the

    analysis. This results in a faster and more economic solution for the user.

    Unit Systems

    The user is allowed to input data and request output in almost all commonly used engineering unit

    systems including MKS, SI and FPS. In the input file, the user may change units as many times as

  • 7/27/2019 Staad Pro Book.docx

    3/26

    required. Mix and match between length and force units from different unit systems is also allowed. The

    input-unit for angles (or rotations) is degrees. However, in JOINT DISPLACEMENT output, the rotations

    are provided in radians. For all output, the units are clearly specified by the program.

    Structure Geometry and Coordinate Systems

    A structure is an assembly of individual components such as beams, columns, slabs, plates etc.. In

    STAAD, frame elements and plate elements may be used to model the structural components. Typically,

    modeling of the structure geometry consists of two steps:

    A. Identification and description of joints or nodes.

    B. Modeling of members or elements through specification of connectivity (incidences) between joints.

    In general, the term MEMBER will be used to refer to frame elements and the term ELEMENT will be

    used to refer to plate/shell and solid elements. STAAD uses two types of coordinate systems to define

    the structure geometry and loading patterns. The GLOBAL coordinate system is an arbitrary coordinate

    system in space which is utilized to specify the overall geometry & loading pattern of the structure. A

    LOCAL coordinate system is associated with each member (or element) and is utilized in MEMBER END

    FORCE output or local load specification. For input, refer the 'Related Topics' below.

    Global Coordinate System

    The following coordinate systems are available for specification of the structure geometry.

    1. Conventional Cartesian coordinate system: This coordinate system (Fig. 1.2) is a rectangularcoordinate system (X, Y, Z) which follows the orthogonal right hand rule. This coordinate system

    may be used to define the joint locations and loading directions. The translational degrees of

    freedom are denoted by u1, u2, u3 and the rotational degrees of freedom are denoted by u4, u5& u6.

    2. Cylindrical Coordinate System: In this coordinate system, (Fig. 1.3) the X and Y coordinates ofthe conventional Cartesian system are replaced by R (radius) and (angle in degrees). The Z

    coordinate is identical to the Z coordinate of the Cartesian system and its positive direction is

    determined by the right hand rule.

    3. Reverse Cylindrical Coordinate System: This is a cylindrical type coordinate system (Fig. 1.4)where the R- plane corresponds to the X-Z plane of the Cartesian system. The right hand rule

    is followed to determine the positive direction of the Y axis.

  • 7/27/2019 Staad Pro Book.docx

    4/26

  • 7/27/2019 Staad Pro Book.docx

    5/26

    Local Coordinate System

    A local coordinate system is associated with each member. Each axis of the local orthogonal coordinate

    system is also based on the right hand rule. Fig. 1.5 shows a beam member with start joint 'I' and end

    joint 'j'. The positive direction of the local x-axis is determined by joining 'I' to 'j' and projecting it in the

    same direction. The right hand rule may be applied to obtain the positive directions of the local y and z

    axes. The local y and z-axes coincide with the axes of the two principal moments of inertia. Note that the

    local coordinate system is always rectangular.

    A wide range of cross-sectional shapes may be specified for analysis. These include rolled steel shapes,

    user specified prismatic shapes etc..

    Loads

    Loads in a structure can be specified as joint load, member load, temperature load and fixed-end

    member load. STAAD can also generate the self-weight of the structure and use it as uniformly

    distributed member loads in analysis. Any fraction of this self-weight can also be applied in any desired

    direction.

    Joint Load

    Joint loads, both forces and moments, may be applied to any free joint of a structure. These loads act in

    the global coordinate system of the structure. Positive forces act in the positive coordinate directions.

    Any number of loads may be applied on a single joint, in which case the loads will be additive on that

    joint.

    Member Load

    Three types of member loads may be applied directly to a member of a structure. These loads areuniformly distributed loads, concentrated loads, and linearly varying loads (including trapezoidal).

    Uniform loads act on the full or partial length of a member. Concentrated loads act at any intermediate,

    specified point. Linearly varying loads act over the full length of a member. Trapezoidal linearly varying

    loads act over the full or partial length of a member. Trapezoidal loads are converted into a uniform load

    and several concentrated loads.

    Area / One-way Load / Floor Load

    Often a floor is subjected to a uniform pressure. It could require a lot of work to calculate the equivalent

    member load for individual members in that floor. However, with the AREA, ONEWAY or FLOOR LOAD

    facilities, the user can specify the pressure (load per unit square area). The program will calculate thetributary area for these members and calculate the appropriate member loads. The Area Load and One-

    way load are used for one way distribution and the Floor Load is used for two way distribution.

    The following assumptions are made while transferring the area/floor load to member load:

    a) The member load is assumed to be a linearly varying load for which the start and the end values may

    be of different magnitude.

  • 7/27/2019 Staad Pro Book.docx

    6/26

    b) Tributary area of a member with an area load is calculated based on half the spacing to the nearest

    approximately parallel members on both sides. If the spacing is more than or equal to the length of the

    member, the area load will be ignored.

    c) Area/Floor load should not be specified on members declared as MEMBER CABLE, MEMBER TRUSS,

    MEMBER TENSION or MEMBER COMPRESSION or CURVED.

    Fixed End Member Load

    Load effects on a member may also be specified in terms of its fixed end loads. These loads are given in

    terms of the member coordinate system and the directions are opposite to the actual load on the

    member. Each end of a member can have six forces: axial; shear y; shear z; torsion; moment y, and

    moment z.

    Prestress and Poststress Member Load

    Members in a structure may be subjected to prestress load for which the load distribution in the

    structure may be investigated. The prestressing load in a member may be applied axially or eccentrically.

    The eccentricities can be provided at the start joint, at the middle, and at the end joint. These

    eccentricities are only in the local y-axis. A positive eccentricity will be in the positive local y-direction.

    Since eccentricities are only provided in the local y-axis, care should be taken when providing prismatic

    properties or in specifying the correct BETA angle when rotating the member coordinates, if necessary.

    Two types of prestress load specification are available; PRESTRESS, where the effects of the load are

    transmitted to the rest of the structure, and POSTSTRESS, where the effects of the load are experienced

    exclusively by the members on which it is applied.

    Temperature and Strain Load

    Temperature difference through the length of a member as well as differences of both faces ofmembers and elements may also be specified. The program calculates the axial strain (elongation and

    shrinkage) due to the temperature difference. From this it calculates the induced forces in the member

    and the analysis is done accordingly. The strain intervals of elongation and shrinkage can be input

    directly.

    Support Displacement Load

    Static Loads can be applied to the structure in terms of the displacement of the supports. Displacement

    can be translational or rotational. Translational displacements are provided in the specified length while

    the rotational displacements are always in degrees. Note that displacements can be specified only in

    directions in which the support has an "enforced" specification in the Support command.

  • 7/27/2019 Staad Pro Book.docx

    7/26

    NOMENCLATURE OF STEEL SECTIONS

    BEAM SECTIONS: Following nomenclature is followed for steel beam sections in India:

    (1) ISJB: Indian standard junior beams(2) ISLB: Indian standard light weight beams(3) ISMB: Indian standard medium weight beams(4) ISWB: Indian standard wide flange beams(5) ISHB: Indian standard heavy weight beams

    Beams will be designated by Type Web x Flange size (E.g ISMB 600x210)

    PARALLEL FLANGE BEAMS:

    (1) NPB: Indian national narrow parallel flange beams(2) WPB: Indian national wide parallel flange beams(3) UB: Universal beams(4) UC: Universal columns

    Parallel beams will be designated by Type Web size x Flange size x Unit weight (E.g UB

    610x229x125)

    ANGLES:

    (1) ISA: Indian standard equal angle(2) ISUA: Indian standard unequal angle

    Angles will be designated by Type Face1 size x Face2 size x Thickness (E.g ISA 100x100x6)

    CHANNELS:

    (1) ISJC: Indian standard junior channel(2) ISLC: Indian standard light weight channel(3) ISMC: Indian standard medium weight channel

    Channel will be designated by Type Web size x Flange size (E.g ISMC 100x50)

    RAILS:

    (1) ISCR: Indian standard crane rail(2) ISHR: Indian standard heavy rail

    Rails will be designated by Type Head size (E.g ISCR 100)

    PLATES:

    Plates will be designated by thickness.

  • 7/27/2019 Staad Pro Book.docx

    8/26

    FLATS:

    Flats will be designated by Width x Thickness (E.g Flat 100x6)

    ROUND BAR:

    (1) ISRO: Indian standard roundRound bar will be designated by Diameter (E.g ISRO 50)

    HEXAGON BAR:

    Hexagon bar will be designated by one side (E.g Hex. Bar 50)

    SQUARE BAR:

    Square bar will be designated by one side size (E.g Sq. Bar 100)

    SQUARE HOLLOW BAR:

    Square hollow bar will be designated by Sq. Bar Face1 size x Face2 size x Thickness (E.g Sq. Bar

    50x50x2)

    RECTANGULAR HOLLOW SECTION:

    Rectangular hollow bar will be designated by Rect. Bar Face1 size x Face size2 x Thickness (E.g

    Rect. Sq. Bar 100x50x2).

  • 7/27/2019 Staad Pro Book.docx

    9/26

    STEEL STRUCTURE DESIGN AS PER IS800

    STAAD contains a broad set of facilities for designing structural members as individual components of an

    analyzed structure. The member design facilities provide the user with the ability to carry out a number

    of different design operations. These facilities may be used selectively in accordance with the

    requirements of the design problem. The operations to perform a design are:

    Specify the members and the load cases to be considered in the design. Specify whether to perform code checking or member selection. Specify design parameter values, if different from the default values. Specify whether to perform member selection by optimization.

    These operations may be repeated by the user any number of times depending upon the design

    requirements. The entire ISI steel section table is supported. Section 8B.13 describes the specification of

    steel sections.

    Allowable Stresses

    The member design and code checking in STAAD are based upon the allowable stress design method as

    per IS: 800 (1984). It is a method for proportioning structural members using design loads and forces,

    allowable stresses, and design limitations for the appropriate material under service conditions. It would

    not be possible to describe every aspect of IS: 800 in this manual. This section, however, will discuss the

    salient features of the allowable stresses specified by IS: 800 and implemented in STAAD. Appropriate

    sections of IS: 800 will be referenced during the discussion of various types of allowable stresses.

    Design Parameters

    In STAAD implementation of IS: 800, the user is allowed complete control of the design process throughthe use of design parameters. Users should note that when the TRACK parameter is set to 1.0 and use in

    conjunction with this code, allowable bending stresses in compression (FCY & FCZ), tension (FTY & FTZ),

    and allowable shear stress (FV) will be printed out in Member Selection and Code Check output in Mpa.

    When TRACK is set to 2.0, detailed design output will be provided.

    Stability Requirements

    Slenderness ratios are calculated for all members and checked against the appropriate maximum values.

    Section 3.7 of IS: 800 summarizes the maximum slenderness ratios for different types of members. In

    STAAD implementation of IS: 800, appropriate maximum slenderness ratio can be provided for each

    member. If no maximum slenderness ratio is provided, compression members will be checked against a

    maximum value of 180 and tension members will be checked against a maximum value of 400.

    Truss Members

    As mentioned earlier, a truss member is capable of carrying only axial forces. So in design no time is

    wasted in calculating bending or shear stresses, thus reducing design time considerably. Therefore, if

  • 7/27/2019 Staad Pro Book.docx

    10/26

    there is any truss member in an analysis (like bracing or strut, etc.), it is wise to declare it as a truss

    member rather than as a regular frame member with both ends pinned.

    Deflection Check

    This facility allows the user to consider deflection as a criterion in theCODE CHECKandMEMBER

    SELECTIONprocesses. The deflection check may be controlled using three parameters which are

    described in Table 7B.1. Note that deflection is used in addition to other strength and stability related

    criteria. The local deflection calculation is based on the latest analysis results.

    Code Checking

    The purpose of code checking is to verify whether the specified section is capable of satisfying applicable

    design code requirements. The code checking is based on the IS: 800 (1984) requirements. Forces and

    moments at specified sections of the members are utilized for the code checking calculations. Sections

    may be specified using the BEAM parameter or the SECTION command. If no sections are specified, the

    code checking is based on forces and moments at the member ends.

    The code checking output labels the members as Passed or Failed. In addition, the critical condition

    (applicable IS: 800 clause no.), governing load case, location (distance from the start) and magnitudes of

    the governing forces and moments are also printed out.

    Member Selection

    STAAD is capable of performing design operations on specified members. Once an analysis has been

    performed, the program can select the most economical section that is the lightest section, which

    satisfies the applicable code requirements. The section selected will be of the same type (I-Section,

    Channel etc.) as originally specified by the user. Member selection may be performed with all types of

    steel sections listed in Section 7B.13 and user provided tables. Selection of members, whose propertiesare originally provided from user specified table, will be limited to sections in the user provided table.

    Member selection cannot be performed on members whose cross sectional properties are specified as

    PRISMATIC.

    It may be noted that the parameters DMAX and DMIN may be used to specify member depth

    constraints for selection. If PROFILE parameter is provided, the search for the lightest section is

    restricted to that profile. Up to three (3) profiles may be provided for any member with a section being

    selected from each one.

    Member Selection by Optimization

    Steel section selection of the entire structure may be optimized. The optimization method utilizes a

    state-of-the -art numerical technique which requires automatic multiple analysis. The user may start

    without a specifically designated section. However, the section profile type (BEAM, COLUMN, CHANNEL,

    ANGLE etc.) must be specified using the ASSIGN command. The optimization is based on member

    stiffness contributions and corresponding force distributions. An optimum member size is determined

    through successive analysis/design iterations. This method requires substantial computer time and

    hence should be used with caution.

  • 7/27/2019 Staad Pro Book.docx

    11/26

    Tabulated Results of Steel Design

    For code checking or member selection, the program produces the result in a tabulated fashion. The

    items in the output table are explained as follows:

    a) MEMBER refers to the member number for which the design is performed.

    b) TABLE refers to the INDIAN steel section name which has been checked against the steel code or has

    been selected.

    c) RESULT prints whether the member has PASSED or Failed. If the RESULT is FAIL, there will be an

    asterisk (*) mark in front of the member number.

    d) CRITICAL COND refers to the section of the IS: 800 code which governs the design.

    e) RATIO prints the ratio of the actual stresses to allowable stresses for the critical condition. Normally a

    value of 1.0 or less will mean the member has passed.

    f) LOADING provides the load case number which governs the design.

    g) FX, MY and MZ provide the axial force, moment in local y-axis and moment in local z-axis respectively.

    Although STAAD does consider all the member forces and moments (except torsion) to perform design,

    only FX, MY and MZ are printed since they are the ones which are of interest, in most cases.

    h) LOCATION specifies the actual distance from the start of the member to the section where design

    forces govern.

    i) If the parameter TRACK is set to 1.0, the program will block out part of the table and will print

    allowable bending stresses in compression (FCY & FCZ) and tension (FTY & FTZ), allowable axial stress incompression (FA), and allowable shear stress (FV).

    Indian Steel Table

    This is an important feature of the program since the program will read section properties of a steel

    member directly from the latest ISI steel tables (as published in ISI-800). These properties are stored in

    memory corresponding to the section designation (e.g. ISMB250, etc.). If called for, the properties are

    also used for member design. Since the shear areas are built in to these tables, shear deformation is

    always considered for these members. Almost all ISI steel tables are available for input. A complete

    listing of the sections available in the built-in steel section library may be obtained using the tools of the

    graphical user interface.

    Following are the descriptions of all the types of sections available:

    Rolled Steel Beams (ISJB, ISLB, ISMB and ISHB).

    All rolled steel beam sections are available the way they are designated in the ISI handbook. E.g.

    ISJB225, ISWB400, etc.

  • 7/27/2019 Staad Pro Book.docx

    12/26

    In case of two identical beams, the heavier beam is designated with an A on the end. E.g. ISHB400 A,

    etc.

    Rolled Steel Channels (ISJC, ISLCand ISMC)

    All these shapes are available as listed in ISI section handbook. Designation of the channels is as per the

    scheme used by ISI.

    Double Channels

    Back to back double channels, with or without spacing between them, are available. The letter D in front

    of the section name will specify a double channel, e.g. D ISJC125, D ISMC75 etc.

    Rolled Steel Angles

    Both rolled steel equal angles and unequal angles are available for use in the STAAD implementation of

    ISI steel tables.

    Double Angles

    Short leg back to back or long leg back to back double angles can be specified by inputting the word SD

    or LD, respectively, in front of the angle size. In case of an equal angle either LD or SD will serve the

    purpose.

    Rolled Tees (ISHT, ISST, ISLT and ISJT)

    All the rolled tee sections are available for input as they are specified in the ISI handbook.

    Pipes (Circular Hollow Sections)

    To designate circular hollow sections from ISI tables, use PIP followed by the numerical value of

    diameter and thickness of the section in mm omitting the decimal section of the value provided for

    diameter.

    Circular pipe sections can also be specified by providing the outside and inside diameters of the section.

    Only code checking and no member selection will be performed if this type of specification is used.

    Tubes (Rectangular or Square Hollow Sections)

    Designation of tubes from the ISI steel table is illustrated below.

  • 7/27/2019 Staad Pro Book.docx

    13/26

    Tubes, like pipes, can also be input by their dimensions (Height, Width and Thickness) and not by any

    table designations.

    Note that only code checking and no member selection is performed for TUBE sections specified this

    way.

    Plate and Angle Girders (With Flange Plates)

    All plate and angle grinders (with flange plates) are available as listed in ISI section handbook. The

    following example with explanations will be helpful in understanding the input procedure.

    SINGLE JOIST WITH CHANNELS AND PLATES ON THE FLANGES TO BE USED AS GIRDERS

    All single joists with channel and plates on the flanges to be used as girders are available as listed in ISI

    section handbook. The following example with explanations will be helpful in understanding the input

    procedure.

  • 7/27/2019 Staad Pro Book.docx

    14/26

  • 7/27/2019 Staad Pro Book.docx

    15/26

    STEEL DESIGN PER IS802

    Allowable Stresses

    The member design and code checking in STAAD are based upon the allowable stress design method as

    per IS: 802 (1995). It is a method for proportioning structural members using design loads and forces,

    allowable stresses, and design limitations for the appropriate material under service conditions.

    This section discusses the salient features of the allowable stresses specified by IS: 802 and

    implemented in STAAD.

    Stability Requirements

    Slenderness ratios are calculated for all members and checked against the appropriate maximum values.

    Minimum Thickness Requirement

    As per Clause7.1 of IS: 802-1995 minimum thickness of different tower members shall be as follows

    Code Checking

    The purpose of code checking is to verify whether the specified section is capable of satisfying applicable

    design code requirements. The code checking is based on the IS: 802 (1995) requirements. Axial forces

    at two ends of the members are utilized for the code checking calculations. The code checking output

    labels the members as Passed or Failed. In addition, the critical condition, governing load case, location

    (distance from the start) and magnitudes of the governing forces are also printed out. Using TRACK 9option calculation steps are also printed.

  • 7/27/2019 Staad Pro Book.docx

    16/26

    Design Steps

    The following are the steps followed in member design.

    Step 1

    Thickness of the member (maximum of web and flange thicknesses) is checked against minimum

    allowable thickness, depending upon whether the member is painted or galvanized.

    Step 2

    If the minimum thickness criterion is fulfilled, the program determines whether the member is under

    compression or tension for the load case under consideration. Depending upon whether the member is

    under tension or compression the slenderness ratio of the member is calculated. This calculated ratio is

    checked against allowable slenderness ratio.

    Step 3

    If the slenderness criterion is fulfilled check against allowable stress is performed. Allowable axial and

    tensile stresses are calculated. If the member is under tension and there is no user defined net section

    factor (NSF), the net section factor is calculated by the program itself. Actual axial stress in the member

    is calculated. The ratio for actual stress to allowable stress, if less than 1.0 or user defined value, the

    member has passed the check.

    Step 4

    Number of bolts required for the critical load case is calculated.

    Member Selection

    STAAD is capable of performing design operations on specified members. Once an analysis has been

    performed, the program can select the most economical section i.e. the lightest section, which satisfies

    the applicable code requirements. The section selected will be of the same type (either angle or

    channel) as originally specified by the user. Member selection may be performed with all angle or

    channel sections and user provided tables. Selection of members, whose properties are originally

    provided from user specified table, will be limited to sections in the user provided table.

    Member Selection by Optimization

    Steel section selection of the entire structure may be optimized. The optimization method utilizes astate-of-the -art numerical technique which requires automatic multiple analysis. The optimization is

    based on member stiffness contributions and corresponding force distributions.

    An optimum member size is determined through successive analysis/design iterations. This method

    requires substantial computer time and hence should be used with caution.

  • 7/27/2019 Staad Pro Book.docx

    17/26

    CONCRETE DESIGN PER IS456

    Member Dimensions

    Concrete members which will be designed by the program must have certain section properties input

    under the MEMBER PROPERTY command. The following example shows the required input:

    will be done accordingly. In the above input, the first set of members are rectangular (450 mm depth

    and 250mm width) and the second set of members, with only depth and no width provided, will be

    assumed to be circular with 350 mm diameter. The third set numbers in the above example represents a

    T-shape with 750 mm flange width, 200 width, 400 mm overall depth and 100 mm flange depth (See

    section 6.20.2). The program will determine whether the section is rectangular, flanged or circular and

    the beam or column design

    Design Parameters

    The program contains a number of parameters which are needed to perform design as per IS:

    456(2000). Default parameter values have been selected such that they are frequently used numbers

    for conventional design requirements. These values may be changed to suit the particular design being

    performed. It is necessary to declare length and force units as Millimeter and Newton before performing

    the concrete design.

    Slenderness Effects and Analysis Consideration

    Slenderness effects are extremely important in designing compression members. The IS: 456 code

    specifies two options by which the slenderness effect can be accommodated (Clause 39.7). One option is

    to perform an exact analysis which will take into account the influence of axial loads and variable

    moment of inertia on member stiffness and fixed end moments, the effect of deflections on moment

    and forces and the effect of the duration of loads. Another option is to approximately magnify design

    moments.

    STAAD has been written to allow the use of the first options. To perform this type of analysis, use the

    command PDELTA ANALYSIS instead of PERFORM ANALYSIS. The PDELTA ANALYSIS will accommodate all

    requirements of the second- order analysis described by IS: 456, except for the effects of the duration of

    the loads. It is felt that this effect may be safely ignored because experts believe that the effects of the

    duration of loads are negligible in a normal structural configuration.

  • 7/27/2019 Staad Pro Book.docx

    18/26

    Although ignoring load duration effects is somewhat of an approximation, it must be realized that the

    approximate evaluation of slenderness effects is also an approximate method. In this method, additional

    moments are calculated based on empirical formula and assumptions on sideway.

    (Clause 39.7.1 and 39.7.1.1 IS: 456 - 2000).

    Considering all these information, a PDELTA ANALYSIS, as performed by STAAD may be used for the

    design of concrete members. However the user must note, to take advantage of this analysis, all the

    combinations of loading must be provided as primary load cases and not as load combinations. This is

    due to the fact that load combinations are just algebraic combinations of forces and moments, whereas

    a primary load case is revised during the P-delta analysis based on the deflections. Also note that the

    proper factored loads (like 1.5 for dead load etc.) should be provided by user. STAAD does not factor the

    loads automatically.

    Beam Design

    Beams are designed for flexure, shear and torsion. If required the effect the axial force may be taken

    into consideration. For all these forces, all active beam loadings are pre scanned to identify the criticalload cases at different sections of the beams. The total number of sections considered is 13( e.g.

    0.,.1,.2,.25,.3,.4,.5,.6,.7,.75,.8,.9 and 1). All of these sections are scanned to determine the design force

    envelopes.

    Design for Flexure

    Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile

    stress at the top face) moments are calculated for all active load cases at each of the above mentioned

    sections. Each of these sections is designed to resist both of these critical sagging and hogging moments.

    Where ever the rectangular section is inadequate as singly reinforced section, doubly reinforced section

    is tried. However, presently the flanged section is designed only as singly reinforced section undersagging moment. It may also be noted all flanged sections are automatically designed as rectangular

    section under hogging moment as the flange of the beam is ineffective under hogging moment. Flexural

    design of beams is performed in two passes. In the first pass, effective depths of the sections are

    determined with the assumption of single layer of assumed reinforcement and reinforcement

    requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal

    database in single or multiple layers. The entire flexure design is performed again in a second pass

    taking into account of the changed effective depths of sections calculated on the basis of reinforcement

    provide after the preliminary design. Final provision of flexural reinforcements is made then. Efforts

    have been made to meet the guideline for the curtailment of reinforcements as per IS: 456-2000 (Clause

    26.2.3). Although exact curtailment lengths are not mentioned explicitly in the design output (finally

    which will be more or less guided by the detailer taking into account of other practical consideration),user has the choice of printing reinforcements provided by STAAD at 11 equally spaced sections from

    which the final detail drawing can be prepared.

    Design for Shear

    Shear reinforcement is calculated to resist both shear forces and torsion moments. Shear design are

    performed at 11 equally spaced sections (0.to 1.) for the maximum shear forces amongst the active load

  • 7/27/2019 Staad Pro Book.docx

    19/26

    cases and the associated torsion moments. Shear capacity calculation at different sections without the

    shear reinforcement is based on the actual tensile reinforcement provided by STAAD program. Two-

    legged stirrups are provided to take care of the balance shear forces acting on these sections.

    As per Clause 40.5 of IS: 456-2000 shear strength of sections (< 2d where d is the effective depth) close

    to support has been enhanced, subjected to a maximum value of cmax.

    Beam Design Output

    The default design output of the beam contains flexural and shear reinforcement provided at 5 equally

    spaced (0, .25, .5, .75 and 1.0) sections along the length of the beam. User has option to get a more

    detail output. All beam design outputs are given in IS units.

    Beam Design

    Beams are designed for flexure, shear and torsion. If required the effect the axial force may be taken

    into consideration. For all these forces, all active beam loadings are pre scanned to identify the critical

    load cases at different sections of the beams. The total number of sections considered is 13( e.g.

    0.,.1,.2,.25,.3,.4,.5,.6,.7,.75,.8,.9 and 1). All of these sections are scanned to determine the design force

    envelopes.

    Design for Flexure

    Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile

    stress at the top face) moments are calculated for all active load cases at each of the above mentioned

    sections. Each of these sections is designed to resist both of these critical sagging and hogging moments.

    Where ever the rectangular section is inadequate as singly reinforced section, doubly reinforced section

    is tried. However, presently the flanged section is designed only as singly reinforced section under

    sagging moment. It may also be noted all flanged sections are automatically designed as rectangularsection under hogging moment as the flange of the beam is ineffective under hogging moment. Flexural

    design of beams is performed in two passes. In the first pass, effective depths of the sections are

    determined with the assumption of single layer of assumed reinforcement and reinforcement

    requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal

    database in single or multiple layers. The entire flexure design is performed again in a second pass

    taking into account of the changed effective depths of sections calculated on the basis of reinforcement

    provide after the preliminary design. Final provision of flexural reinforcements is made then. Efforts

    have been made to meet the guideline for the curtailment of reinforcements as per IS: 456-2000 (Clause

    26.2.3). Although exact curtailment lengths are not mentioned explicitly in the design output (finally

    which will be more or less guided by the detailer taking into account of other practical consideration),

    user has the choice of printing reinforcements provided by STAAD at 11 equally spaced sections fromwhich the final detail drawing can be prepared.

    Design for Shear

    Shear reinforcement is calculated to resist both shear forces and torsion moments. Shear design are

    performed at 11 equally spaced sections (0.to 1.) for the maximum shear forces amongst the active load

    cases and the associated torsion moments. Shear capacity calculation at different sections without the

  • 7/27/2019 Staad Pro Book.docx

    20/26

    shear reinforcement is based on the actual tensile reinforcement provided by STAAD program. Two-

    legged stirrups are provided to take care of the balance shear forces acting on these sections.

    As per Clause 40.5 of IS: 456-2000 shear strength of sections (< 2d where d is the effective depth) close

    to support has been enhanced, subjected to a maximum value of cmax.

    Beam Design Output

    The default design output of the beam contains flexural and shear reinforcement provided at 5 equally

    spaced (0, .25, .5, .75 and 1.0) sections along the length of the beam. User has option to get a more

    detail output. All beam design outputs are given in IS units.

    Wall Design in accordance with IS 456-2000

    Design of walls in accordance with IS 456-2000 is available in STAAD.Pro. Design is per formed for in-

    plane shear, in-plane and out-of-plane bending and out-of-plane shear. The wall has to be

    modeled using STAADsSurface elements. The use of the Surface element enables the designer

    to treat the entire wall as one entity. It greatly simplifies the mo deling of the wall and adds

    clarity to the analysis and design output. The results are presented in the context of the

    entire wall rather than individual finite elements thereby allowing users to quickly locate

    required information.

    The program reports shear wall design results for each load case/combination for user specified number

    of sections given by SURFACE DIVISION (default value is 10) command. The shear wall is designed at

    these horizontal sections. The output includes the required horizontal and vertical distributed

    reinforcing, the concentrated (in-plane bending) edge reinforcing and the link required for out-of-plane

    shear.

  • 7/27/2019 Staad Pro Book.docx

    21/26

    Tutorial Problem 1

    Description of the Tutorial Problem

    The structure for this project is a single bay, single story steel portal frame that will be analyzedand designed. The figure below shows the structure.

  • 7/27/2019 Staad Pro Book.docx

    22/26

    BASIC DATA FOR THE STRUCTURE

  • 7/27/2019 Staad Pro Book.docx

    23/26

    Tutorial Problem 2

    Description of the Tutorial Problem

    The structure for this project is a 2 bay, 2 story reinforced concrete frame. The figurebelow shows the structure. Our goal is to create the model, assign all required input,

    and perform the analysis and concrete design.

  • 7/27/2019 Staad Pro Book.docx

    24/26

    BASIC DATA FOR THE STRUCTURE

  • 7/27/2019 Staad Pro Book.docx

    25/26

    Tutorial Problem 3

    Description of the tutorial problem

    The structure for this project is a slab fixed along two edges. We will model it using 6quadrilateral (4-noded) plate elements. The structure and the mathematical model are

    shown in the figures below. It is subjected to selfweight, pressure loads and temp erature

    loads. Our goal is to create the model, assign all required input, perform the analysis,and go through the results.

  • 7/27/2019 Staad Pro Book.docx

    26/26

    BASIC DATA FOR THE STRUCTURE