spring guided epidural catheter for pain relief at ... · pharmathen s.a 5 ropivacaína aurovitas...

4
Spring guided epidural catheter for pain relief at cervical and lumbar region.

Upload: others

Post on 02-Sep-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Spring guided epidural catheter for pain relief at ... · Pharmathen S.A 5 Ropivacaína Aurovitas PT/H/1662/001, PT/H/1662/002, PT/H/1662/004, PT/H/1662/004 Actavis Group NO. PRODUCT

Spring guided epidural catheter

for pain relief at cervical

and lumbar region.

Page 2: Spring guided epidural catheter for pain relief at ... · Pharmathen S.A 5 Ropivacaína Aurovitas PT/H/1662/001, PT/H/1662/002, PT/H/1662/004, PT/H/1662/004 Actavis Group NO. PRODUCT

EPINAUT™ spring guided epidural catheter is a specialized catheter for pain relief at cervical or lumbar region. EPINAUT™ spring guided epidural catheter is constructed from a continuous stainless steel spring, introducer needle and adapter. EPINAUT™ spring guided epidural catheter is able to enter the epidural space around the spine and deliver medication in order to treat the cause of pain.

▪ Local anesthesia▪ Minimal invasive▪ Short procedure▪ Quick recovery

ADVANTAGES

▪ Improved tensile strength ▪ Radiopaque for clear image▪ Surgical grade stainless steel▪ Flexible and rounded tip

FEATURES

▪ Chronic neck & back pain▪ Spinal stenosis▪ Spinal disc herniation▪ Post laminectomy pain syndrome

INDICATIONS

SPECIFICATION & ORDERING INFORMATION

REF NO. SPINAL AREA DESCRIPTION CATHETERLENGTH

CATHETERDIAMETER

CS31011315B Cervical Spring guided epidural catheter (incl. Needle) 31 cm 22 G 0.75 mm

L60011320B Lumbar Spring guided epidural catheter (incl. Needle) 60 cm 19 G 1.10 mm

Catheter

Adapter

Cervical Tip

Lumbar Tip

Page 3: Spring guided epidural catheter for pain relief at ... · Pharmathen S.A 5 Ropivacaína Aurovitas PT/H/1662/001, PT/H/1662/002, PT/H/1662/004, PT/H/1662/004 Actavis Group NO. PRODUCT

Introducer Needle

Wire

CLAIMS FOR CLINICAL PERFORMANCE- EPINAUT meet the requirements of ISO 10555-1 standard.- Catheter is composed of corrosion resistancy material.- Leakage is not found at the pressure 3 kgf/cm2.- Force of break(tensile strength) is more than 15N.- Catheter can be recognized by C-arm or other X-ray facilities.

CONTRAINDICATIONThe use of the EPINAUT Spring Guide Epi-dural Catheter contradicated in patients who: are unwilling, uncooperative or un-able to give consent; or have local or sys-temic infections, bleedings disorders, aller-gies to the medications to be used during the procedure, anatomical derangements that may prevent procedural success or needle phobias.

COMPLICATIONSEpidural catheter complications are very rare, but when they do occur they can be serious- Post Dural Puncture Headache- Seizures - Backache- Cauda Equina Syndrome- Total Spinal Injection- Anaphylaxis- Neurologic injury- Spinal Hematoma

Page 4: Spring guided epidural catheter for pain relief at ... · Pharmathen S.A 5 Ropivacaína Aurovitas PT/H/1662/001, PT/H/1662/002, PT/H/1662/004, PT/H/1662/004 Actavis Group NO. PRODUCT

IMEDICOM CO., LTD.#612, 172, LS-ro, Gunpo-si, Gyeonggi-do, 15807, Korea Tel : +82 31 479 1156 Fax : +82 31 479 1157 www.imedicom.co.kr

Distributed by

CAR-

EPE-

39 (R

ev.1

, 202

0-01

-27)

MEDICINES CONTACTING WITH DEVICE

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 Iohexol AT/H/0637/001,AT/H/0637/002 b.e. imaging gmbh

2 NITIGRAF NL/H/3785/001,NL/H/3785/002

3 Iohexol Imax PT/H/1099/001,PT/H/1099/002 60 cm

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 LidocaineAguettant

DE/H/4804/001,DE/H/4804/002

Laboratoire Aguettant

2 Ryligency DE/H/4804/003,DE/H/5266/001

Laboratoire Aguettant

3 IMydrane DK/H/2439/001 Laboratoires Thea

4 Neiraxin B EE/H/0239/001 AS Kalceks

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 Sodium ChloridePROAMP FR/H/0302/001 Aguettant

2 Sodium ChloridePROAMP ES/H/0135/001 Fresenius Kabi

3 NatriumchloridMallinckrodt DE/H/3874/001 Guerbet

4 NaCl Guerbet PT/H/2269/001 Guerbet

5 Sodium ChlorureGrifols EE/H/0239/001 Laboratorios

Grifols, S.A.

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 Metilprednizolon-Teva

HU/H/0317/001,HU/H/0317/002,HU/H/0317/003,HU/H/0317/004

TEVAPharmaceuticalWorks Private

Limited

2 MetilprednisolonaHikma

PT/H/0946/001,PT/H/0946/002,PT/H/0946/003,PT/H/0946/004,PT/H/0946/005

HikmaFarmacêutica

(Portugal),S.A.

3 MethylprednisoloneOrion

FI/H/0797/001,FI/H/0797/002,FI/H/0797/003,FI/H/0797/004

Orion Corporation

4 Methylprednisolut

DE/H/2748/001,DE/H/2748/002,DE/H/4636/001,DE/H/4636/002

mibe GmbH

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 Naropin

NL/H/0104/001,NL/H/0104/002,NL/H/0104/003,NL/H/0104/004

Aspen Pharma TradingLimited

2 Ropivacain HCl B.Braun DE/H/2536/001 B.Braun

Melsungen AG

3 Ropivacain HEXAL

DE/H/2322/001,DE/H/2322/002,DE/H/2322/003,DE/H/2322/004

Hexal AG

4 Ropivacain Pharmathen

AT/H/0605/002,AT/H/0605/003,AT/H/0605/004

Pharmathen S.A

5 RopivacaínaAurovitas

PT/H/1662/001,PT/H/1662/002,PT/H/1662/004,PT/H/1662/004

Actavis Group

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 TRIESENCE DE/H/2294/001 Novartis Pharma GmbH

2 TRISPAN NL/H/4631/001 IntrapharmLaboratories Ltd

3 Trica FI/H/0900/001 Evolan Pharma

4 Kenacort-T SE/H/1712/001 Bristol-Myers Squibb AB

NO. PRODUCT NAME MR NUMBER MA HOLDER

1 Dexamethasone phosphate IE/H/0609/001 EDMOND PHARMA

SRL

2 DEXAMETHASONE MT/H/0348/001 ELC Group s.r.o

3Dexamethasone sodium phosphate St

ridesUK/H/5163/001 Strides Arcolab

Internation Ltd.

CONTRAST MEDIUM

LIDOCAINE

SODIUM CHLORIDE

※ WARNING: Unauthorized use of these medicines is strictly prohibited.

METHYLPREDNISOLONE

DEXAMETHASONE

TRIAMCINOLONE

ROPIVACAINE