soft starters - ipdipd.com.au/pdf/soft-starter.pdf · - current ramp - current limit - motor trip...

5
Phone: 1300 556 601 www.ipd.com.au Variable Speed Drives 1 SOFT STARTERS Fully-featured motor control solutions

Upload: others

Post on 30-Jan-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SOFT STARTERS - IPDipd.com.au/pdf/soft-starter.pdf · - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence

Phone: 1300 556 601 www.ipd.com.au Variable Speed Drives 1

SOFT STARTERSFully-featured motor control solutions

Page 2: SOFT STARTERS - IPDipd.com.au/pdf/soft-starter.pdf · - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence

www.ipd.com.au Soft Starters Phone: 1300 556 601

CSXi Soft starter• Range: 18A ~ 200A• Voltage ranges: 200 ~ 440VAC (V4) 200 ~ 575VAC (V6)• Protection: IP20/IP00

Features• 7 Adjustments: - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence protection • Compact and light weight• Integrated bypass contactors• Motor protection against operational overload, current spikes & fluctuations • Plug-in communication interfaces• Insulating finger guards

Accessories• Communication options: Profibus, Profinet, DeviceNet, Ethernet/IP, Modbus RTU or Modbus TCP protocols, via easy-to-install communication interfaces• Optional remote operator• Finger guards IP20 protection

Page 3: SOFT STARTERS - IPDipd.com.au/pdf/soft-starter.pdf · - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence

www.ipd.com.au Soft StartersPhone: 1300 556 601

EMX3 Soft starter• Range: 23A ~ 1000A complete with internal bypass 255A ~ 1600A continuous rating non-bypass• Voltage ranges: 200 ~ 440VAC (V4) 380 ~ 690VAC (V7)• Protection: IP20/IP00

Features• Dual motor parameter settings• Constant current and current ramp start• XLR-8 adaptive control starting/stopping• Kickstart• DC brake• Jog function (Forward and Reverse)• Coast to stop and timed voltage ramp stop• Configurable multi-language graphical display• Quick start application setup for easy commissioning• Emergency run mode• Simulation testing (Run, Protection and signaling) • Real time metering and monitoring• Multi-languages graphical display (99 event logs)• Internal Bypass up to 1000A• Inside delta (6 wire) control• SCR fail power through operation• Scheduled automatic start/stop (Timer/clock)• Unique wiring looms and cable retainers make for a faster & tidier installation

Motor Protection• Motor thermistor• Current imbalance• Phase sequence (Forward/Reverse/Any)• Phase loss• Power loss• Restart delay (Pump back spin delay)

Accessories• Remote HMI mounting kit• Communications options: Profibus, Profinet, DeviceNet, Ethernet/IP, Modbus RTU or Modbus TCP protocols, via easy-to-install communication interfaces• Finger guards IP20 protection• Expansion cards: I/O and RTD/Ground Fault

Page 4: SOFT STARTERS - IPDipd.com.au/pdf/soft-starter.pdf · - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence

www.ipd.com.au Soft Starters Phone: 1300 556 601

EMX4i Soft starter• Range: 24A ~ 580A with Internal Bypass (2 frame sizes)• Extended range up to 1250A with Internal Bypass (Q1 2020)• Voltage ranges: 200 ~ 525VAC (V5) 380 ~ 690VAC (V7)• Protection: IP20/IP00

Features:• Dual motor parameter settings• Constant current and current ramp start• XLR-8 adaptive control starting/stopping• Coast to stop and timed voltage ramp stop• Soft trip• Configurable multi-language graphical display• Quick start application setup for easy commissioning• Emergency run mode• Simulation testing (Run, Protection and Signaling)• USB port for easy and fast configuration backups and data protection• Real time metering and monitoring• Multi-languages graphical display (384 event logs)• Smaller and lighter in comparison to EMX3• Kickstart• DC brake• Soft brake• Jog function (Forward and Reverse)• Inside delta (6 wire) control• Automated pump clean function• SCR fail power through operation• Scheduled automatic start/stop (Time of day & day of week)• Motor voltage and power measurement

Motor Protection• Motor thermistor• Current imbalance• Phase sequence (Forward/Reverse/Any)• Phase loss• Power loss• Starts per hour limiting• Restart delay (Pump back spin delay)• Under/Overvoltage• Under/Overpower (Dry pump protection)

Accessories • Finger guards IP20 protection • Communications options: Modbus RTU, Profibus, DeviceNet, Modbus TCP, Profinet, Ethernet IP• Pumping Smart Card• Remote HMI

Page 5: SOFT STARTERS - IPDipd.com.au/pdf/soft-starter.pdf · - Current ramp - Current limit - Motor trip class - Soft stop time - Excess start time - Auxiliary relay function - Phase sequence

BRISBANE

NEWCASTLE

SYDNEY

HOBART

ADELAIDE

MELBOURNE

PERTH

CAIRNS

DARWIN

National Customer Support CentreTel: 1300 556 601 Fax: 1300 550 187 Email: [email protected] www.ipd.com.auIPD Group Ltd. © Copyright 2019