Policy Management SNMP User's Guide 910-6403-001 Revision A June 2012 Copyright 2012 Tekelec. All Rights Reserved. Printed in USA. Legal Information can be accessed from the Main Menu of the optical disc or on the Tekelec Customer Support web site in the Legal Information folder of the Product Support tab.

Upload: ngonguyet

Post on 01-Jan-2017

269 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: SNMP User's Guide

Policy Management

SNMP User's Guide910-6403-001 Revision A

June 2012

Copyright 2012 Tekelec. All Rights Reserved. Printed in USA.Legal Information can be accessed from the Main Menu of the optical disc or on the

Tekelec Customer Support web site in the Legal Information folder of the Product Support tab.

Page 2: SNMP User's Guide

Table of Contents

Chapter 1: About This Guide.............................................................5Conventions...............................................................................................................................6How This Guide is Organized.................................................................................................6Scope and Audience.................................................................................................................6Documentation Admonishments............................................................................................6Customer Care Center..............................................................................................................7Emergency Response................................................................................................................9Related Publications.................................................................................................................9Locate Product Documentation on the Customer Support Site.......................................10

Chapter 2: Overview..........................................................................11Simple Network Management Protocol..............................................................................12The SNMP Standard...............................................................................................................12

Chapter 3: Configuring SNMP.........................................................14SNMP Configuration..............................................................................................................15Configuring SNMP Settings..................................................................................................16

Chapter 4: Supported MIBs..............................................................19Supported MIBs.......................................................................................................................20

Chapter 5: Support for Traps............................................................23Alarms Overview....................................................................................................................24Platform (31000-32700)...........................................................................................................25

Expanded List..............................................................................................................25QBus Platform (70000-70999)................................................................................................59

Expanded List..............................................................................................................59Policy Server Alarms (71000 - 89999)...................................................................................66

Expanded List..............................................................................................................66Glossary....................................................................................................................86

ii910-6403-001 Revision A, June 2012

Page 3: SNMP User's Guide

List of FiguresFigure 1: SNMP Configuration.........................................................................................................15

iii910-6403-001 Revision A, June 2012

Page 4: SNMP User's Guide

List of TablesTable 1: Admonishments.....................................................................................................................6Table 2: SNMP Attributes..................................................................................................................16

iv910-6403-001 Revision A, June 2012

Page 5: SNMP User's Guide

Chapter

1About This Guide

This guide describes Policy Management productsupport for Simple Network Management Protocol(SNMP).

Topics:

• Conventions.....6• How This Guide is Organized.....6• Scope and Audience.....6• Documentation Admonishments.....6• Customer Care Center.....7• Emergency Response.....9• Related Publications.....9• Locate Product Documentation on the Customer

Support Site.....10

5910-6403-001 Revision A, June 2012

Page 6: SNMP User's Guide

Conventions

The following conventions are used throughout this guide:

• Bold text in procedures indicates icons, buttons, links, or menu items that you click on.• Italic text indicates variables.• Monospace text indicates text displayed on screen.

How This Guide is Organized

The information in this guide is presented in the following order:

• About This Guide contains general information about this guide, the organization of this guide, andhow to get technical assistance.

• Overview provides an overview of how Policy Management supports the Simple NetworkManagement Protocol (SNMP).

• Configuring SNMP describes how to configure SNMP using CMP.• Supported MIBs describes the MIBs that are supported for SNMP.• Support for Traps describes the Policy Management functioning of alarms and traps with SNMP.

Scope and Audience

This guide is intended for system integrators and other qualified service personnel responsible formanaging a Policy Management system.

Documentation Admonishments

Admonishments are icons and text throughout this manual that alert the reader to assure personalsafety, to minimize possible service interruptions, and to warn of the potential for equipment damage.

Table 1: Admonishments

DANGER:

(This icon and text indicate the possibility of personal injury.)

WARNING:

(This icon and text indicate the possibility of equipment damage.)

6910-6403-001 Revision A, June 2012

About This Guide

Page 7: SNMP User's Guide

CAUTION:

(This icon and text indicate the possibility of service interruption.)

Customer Care Center

The Tekelec Customer Care Center is your initial point of contact for all product support needs. Arepresentative takes your call or email, creates a Customer Service Request (CSR) and directs yourrequests to the Tekelec Technical Assistance Center (TAC). Each CSR includes an individual trackingnumber. Together with TAC Engineers, the representative will help you resolve your request.

The Customer Care Center is available 24 hours a day, 7 days a week, 365 days a year, and is linkedto TAC Engineers around the globe.

Tekelec TAC Engineers are available to provide solutions to your technical questions and issues 7days a week, 24 hours a day. After a CSR is issued, the TAC Engineer determines the classification ofthe trouble. If a critical problem exists, emergency procedures are initiated. If the problem is not critical,normal support procedures apply. A primary Technical Engineer is assigned to work on the CSR andprovide a solution to the problem. The CSR is closed when the problem is resolved.

Tekelec Technical Assistance Centers are located around the globe in the following locations:

Tekelec - Global

Email (All Regions): [email protected]

• USA and Canada

Phone:

1-888-FOR-TKLC or 1-888-367-8552 (toll-free, within continental USA and Canada)

1-919-460-2150 (outside continental USA and Canada)

TAC Regional Support Office Hours:

8:00 a.m. through 5:00 p.m. (GMT minus 5 hours), Monday through Friday, excluding holidays• Caribbean and Latin America (CALA)

Phone:

USA access code +1-800-658-5454, then 1-888-FOR-TKLC or 1-888-367-8552 (toll-free)

TAC Regional Support Office Hours (except Brazil):

10:00 a.m. through 7:00 p.m. (GMT minus 6 hours), Monday through Friday, excluding holidays

• Argentina

Phone:

0-800-555-5246 (toll-free)• Brazil

Phone:

7910-6403-001 Revision A, June 2012

About This Guide

Page 8: SNMP User's Guide

0-800-891-4341 (toll-free)

TAC Regional Support Office Hours:

8:00 a.m. through 5:48 p.m. (GMT minus 3 hours), Monday through Friday, excluding holidays• Chile

Phone:

1230-020-555-5468• Colombia

Phone:

01-800-912-0537• Dominican Republic

Phone:

1-888-367-8552• Mexico

Phone:

001-888-367-8552• Peru

Phone:

0800-53-087• Puerto Rico

Phone:

1-888-367-8552 (1-888-FOR-TKLC)• Venezuela

Phone:

0800-176-6497

• Europe, Middle East, and Africa

Regional Office Hours:

8:30 a.m. through 5:00 p.m. (GMT), Monday through Friday, excluding holidays

• Signaling

Phone:

+44 1784 467 804 (within UK)• Software Solutions

Phone:

+33 3 89 33 54 00

• Asia

8910-6403-001 Revision A, June 2012

About This Guide

Page 9: SNMP User's Guide

• India

Phone:

+91 124 436 8552 or +91 124 436 8553

TAC Regional Support Office Hours:

10:00 a.m. through 7:00 p.m. (GMT plus 5 1/2 hours), Monday through Saturday, excludingholidays

• Singapore

Phone:

+65 6796 2288

TAC Regional Support Office Hours:

9:00 a.m. through 6:00 p.m. (GMT plus 8 hours), Monday through Friday, excluding holidays

Emergency Response

In the event of a critical service situation, emergency response is offered by the Tekelec Customer CareCenter 24 hours a day, 7 days a week. The emergency response provides immediate coverage, automaticescalation, and other features to ensure that the critical situation is resolved as rapidly as possible.

A critical situation is defined as a problem with the installed equipment that severely affects service,traffic, or maintenance capabilities, and requires immediate corrective action. Critical situations affectservice and/or system operation resulting in one or several of these situations:

• A total system failure that results in loss of all transaction processing capability• Significant reduction in system capacity or traffic handling capability• Loss of the system’s ability to perform automatic system reconfiguration• Inability to restart a processor or the system• Corruption of system databases that requires service affecting corrective actions• Loss of access for maintenance or recovery operations• Loss of the system ability to provide any required critical or major trouble notification

Any other problem severely affecting service, capacity/traffic, billing, and maintenance capabilitiesmay be defined as critical by prior discussion and agreement with the Tekelec Customer Care Center.

Related Publications

The following documents provide additional information:

• Product Release Notes• Configuration Management Platform User’s Guide• Policy Management Troubleshooting Guide

9910-6403-001 Revision A, June 2012

About This Guide

Page 10: SNMP User's Guide

• OSSI XML Interface Definition

Locate Product Documentation on the Customer Support Site

Access to Tekelec's Customer Support site is restricted to current Tekelec customers only. This sectiondescribes how to log into the Tekelec Customer Support site and locate a document. Viewing thedocument requires Adobe Acrobat Reader, which can be downloaded at www.adobe.com.

1. Log into the Tekelec Customer Support site.

Note: If you have not registered for this new site, click the Register Here link. Have your customernumber available. The response time for registration requests is 24 to 48 hours.

2. Click the Product Support tab.3. Use the Search field to locate a document by its part number, release number, document name, or

document type. The Search field accepts both full and partial entries.4. Click a subject folder to browse through a list of related files.5. To download a file to your location, right-click the file name and select Save Target As.

10910-6403-001 Revision A, June 2012

About This Guide

Page 11: SNMP User's Guide

Chapter

2Overview

This chapter provides an overview of PolicyManagement support for the Simple NetworkManagement Protocol (SNMP).

Topics:

• Simple Network Management Protocol.....12• The SNMP Standard.....12

11910-6403-001 Revision A, June 2012

Page 12: SNMP User's Guide

Simple Network Management Protocol

Simple Network Management Protocol (SNMP) is a communication protocol that provides a methodof managing TCP/IP networks, including individual network devices, and devices in aggregate. SNMPwas developed by the IETF (Internet Engineering Task Force), and is applicable to any TCP/IP network,as well as other types of networks.

SNMP is an Application Program Interface (API) to the network, so that general-purpose networkmanagement programs can be easily written to work with a variety of different devices. SNMP definesa client/server relationship. The client program (called the network manager) makes virtual connectionsto a server program (called the SNMP agent. The SNMP agent executes on a remote network deviceand serves information to the manager about the status of the device. The database (referred to as theSNMP Management Information Base or MIB) is a standard set of statistical and control values thatis controlled by the SNMP agent.

Through the use of private MIBs, SNMP allows the extension of the standard values with valuesspecific to a particular agent. SNMP agents can be tailored for a myriad of specific devices such ascomputers, network bridges, gateways, routers, modems, and printers. The definitions of MIB variablessupported by a particular agent are incorporated in descriptor files that are made available to networkmanagement client programs so that they can become aware of MIB variables and their usage. Thedescriptor files are written in Abstract Syntax Notation (ASN.1) format.

Directives are issued by the network manager client to an SNMP agent. Directives consist of theidentifiers of SNMP variables (referred to as MIB object identifiers or MIB variables), along withinstructions to either get the value for the identifier or set the identifier to a new value.

The SNMP Standard

SNMP can be viewed as three distinct standards:

• A Standard Message Format — SNMP is a standard communication protocol that defines a UDPmessage format.

• A Standard Set of Managed Objects — SNMP is a standard set of values (referred to as SNMP"objects") that can be queried from a device. Specifically, the standard includes values for monitoringTCP, IP, UDP, and device interfaces. Each manageable object is identified with an official name,and also with a numeric identifier expressed in dot-notation.

• A Standard Way of Adding Objects — A standard method is defined to allow the standard set ofmanaged objects to be augmented by network device vendors with new objects specific for aparticular network.

SNMP Message Types

Four types of SNMP messages are defined:

• A "get" request returns the value of a named object. Specific values can be fetched to determine theperformance and state of the device, without logging into the device or establishing a TCP connectionwith the device.

12910-6403-001 Revision A, June 2012

Overview

Page 13: SNMP User's Guide

• A "get-next" request returns the next name (and value) of the "next" object supported by a networkdevice given a valid SNMP name. This request allows network managers to "walk" through allSNMP values of a device to determine all names and values that an operant device supports.

• A "set" request sets a named object to a specific value. This request provides a method of configuringand controlling network devices through SNMP to accomplish activities such as disabling interfaces,disconnecting users, and clearing registers.

• A "trap" message is generated asynchronously by network devices, which can notify a networkmanager of a problem apart from any polling of the device: This typically requires each device onthe network to be configured to issue SNMP traps to one or more network devices that are awaitingthese traps.

The four message types are all encoded into messages referred to as "Protocol Data Units" (PDUs),which are interchanged with SNMP devices.

Standard Managed Objects

The list of values that an object supports is referred to as the SNMP "Management Information Base"(MIB). “MIB” can be used to describe any SNMP object or portion of an SNMP hierarchy.

The various SNMP values in the standard MIB are defined in RFC-1213, (one of the governingspecifications for SNMP). The standard MIB includes various objects to measure and monitor IPactivity, TCP activity, UDP activity, IP routes, TCP connections, interfaces, and general systemdescription. Each of these values is associated with an official name (such as "sysUpTime", which isthe elapsed time since the managed device was booted) and with a numeric value expressed indot-notation (such as "1.3.6.1.2.1.1.3.0", which is the "object identifier" for "sysUpTime").

See Supported MIBs for a description of the use of SNMP MIBs for Policy Management.

SNMP Extension

SNMP provides the ability to augment the standard set of MIB objects with new values specific forcertain applications and devices. New function can continuously be added to SNMP, using a standardmethod defined to incorporate that function into SNMP devices and network managers. Adding newfunctions is accomplished through the process of "compiling" a new MIB, which allows the user toadd new MIB definitions to the system. The definitions are usually supplied by network equipmentvendors in specially formatted text files using the ASN.1 standard syntax. (ASN.1 refers to "AbstractSyntax Notation One", which is a type declaration language adopted by SNMP and used a few otherplaces, including encryption and CMIP protocols.)

The MIB of an SNMP device is usually fixed; it is constructed by the network equipment vendor (suchas a router manufacturer or computer hardware vendor) and cannot be added to or modified. Theextension of SNMP refers strictly to SNMP management software, which can become aware of theMIB values supported by the device by compiling a description of the device into the networkmanagement program.

13910-6403-001 Revision A, June 2012

Overview

Page 14: SNMP User's Guide

Chapter

3Configuring SNMP

This chapter describes how to configure SNMPusing the CMP system.

Topics:

• SNMP Configuration.....15• Configuring SNMP Settings.....16

14910-6403-001 Revision A, June 2012

Page 15: SNMP User's Guide

SNMP Configuration

SNMP configuration architecture is based on using traps to notify a network management system ofevents and alarms that are generated by the MPE and MRA application software, and those that aregenerated by the underlying platforms. Alarms and telemetry data are continuously collected fromthe entire Policy Application Network and stored on the CMP servers. Alarms will then cause a trapto be sent as a notification of an event.

Because the underlying platform can deliver the alarms from the MPE/MRA to the CMP, SNMP canbe configured in either of 2 ways:

• The Policy system can be configured so that the CMP is the source of all traps.• The Policy systems can be configured to allow each server to generate its own traps and deliver

them to the SNMP management servers.

Figure 1: SNMP Configuration illustrates the two SNMP configurations.

Figure 1: SNMP Configuration

On the SNMP Settings Edit page (see Configuring SNMP Settings), the check box labeled "Traps fromindividual Servers" determines the mode in which the SNMP notifications will operate. When the boxis checked to have each server generate traps, the Policy systems will operate as shown in the right-handside of SNMP Configuration.

SNMP configuration is pushed from the CMP to the managed servers in the network.

15910-6403-001 Revision A, June 2012

Configuring SNMP

Page 16: SNMP User's Guide

SNMP VersionsSNMP version 2c (SNMPv2c) and SNMP version 3 (SNMPv3) are supported. SNMP version 1 (SNMPv1)is not supported. On the SNMP Setting Edit page (see Configuring SNMP Settings),

• When you configure SNMPv2c, you must use a community that is not "public" or "private".• When you configure SNMPv3, you must enter an "Engine ID", and a "username" and "password"

for the SNMPv3 user.

Configuring SNMP Settings

The CMP system provides a screen for configuring SNMP settings for the CMP system and all MPEand MRA servers in the topology network.

Note: SNMP settings configuration must be done on a server that is the Active Server in the PrimaryCluster. A banner warning appears if the login is not on the primary/active CMP. SNMP cannot beconfigured from servers other than the active/primary CMP.

To configure SNMP settings, do the following:

1. Log into the CMP system from its server address as the Administration user.

The CMP Navigation Pane is displayed.

2. Click on the SNMP Setting link under Platform Setting.

The SNMP Settings attributes are displayed.

3. Click on the Modify button.

The SNMP Settings edit screen is displayed.

4. Edit the SNMP Settings attributes that need to be entered or changed.

Table 2: SNMP Attributes describes the SNMP attributes that can be edited:

Table 2: SNMP Attributes

DescriptionField Name

SNMP Manager to receive traps and send SNMPrequests. Each Manager field can be filled as

Manager 1-5

either a valid host name or an IPv4 address. Ahostname should include only alphanumericcharacters. Maximum length is 20 characters,and it is not case-sensitive. This field can also bean IP address. An IP address should be in astandard dot-formatted IP address string. Thefield is required to allow the Manager to receivetraps.

By default, these fields are empty.

Note: The IPv6 address is not supported.

16910-6403-001 Revision A, June 2012

Configuring SNMP

Page 17: SNMP User's Guide

DescriptionField Name

Supported SNMP versions:Enabled Versions

• SNMPv2c• SNMPv3• SNMPv2c and SNMPv3 (default)

Enable sending SNMPv2 traps (default is boxcheck marked)

Traps Enabled

Disable sending SNMPv2 traps (box not checkmarked)

Enable sending traps from an individual server(box check marked).

Traps from Individual Servers

Sending traps from the active CMP (default isbox not check marked)

The SNMP read-write community string.SNMPv2c Community Name

The field is required if SNMPv2c is enabled.

The name can contain alphanumeric charactersand cannot exceed 31 characters in length.

The name cannot be either “private” or “public”.

The default value is “snmppublic”.

Configured Engine ID for SNMPv3.SNMPv3 Engine ID

The field is required If SNMPv3 is enabled.

The Engine ID includes only hexadecimal digits(0-9 and a-f).

The length can be from 10 to 64 digits.

The default is no value (empty).

The SNMPv3 User Name.SNMPv3 Username

The field is required if SNMPv3 is enabled.

The name must contain alphanumeric charactersand cannot not exceed 32 characters in length.

The default value is “TekSNMPUser”.

SNMPv3 Authentication and Privacy options.SNMPv3 Security Level

1. “No Auth No Priv” - Authenticate using theUsername. No Privacy.

17910-6403-001 Revision A, June 2012

Configuring SNMP

Page 18: SNMP User's Guide

DescriptionField Name

2. “Auth No Priv” - Authentication using MD5or SHA1 protocol.

3. “Auth Priv” - Authenticate using MD5 orSHA1 protocol. Encrypt using the AES andDES protocol.

The default value is “Auth Priv”.

Authentication protocol for SNMPv3. Optionsare:

SNMPv3 Authentication Type

1. “SHA-1” - Use Secure Hash Algorithmauthentication.

2. “MD5” - Use Message Digest authentication.

The default value is “SHA-1”.

Privacy Protocol for SNMPv3. Options are:SNMPv3 Privacy Type

1. “AES”: Use Advanced Encryption Standardprivacy.

2. “DES”: Use Data Encryption Standardprivacy.

The default value is “AES”.

Authentication password for SNMPv3. Thisvalue is also used for msgPrivacyParameters.

SNMPv3 Password

The field is required If SNMPv3 is enabled.

The length of the password must be between 8and 64 characters; it can include any character.

The default value is “snmpv3password”.

5. Click Save to save the changes, or Cancel to discard the changes.

18910-6403-001 Revision A, June 2012

Configuring SNMP

Page 19: SNMP User's Guide

Chapter

4Supported MIBs

This chapter describes the MIBs that are supportedfor SNMP.

Topics:

• Supported MIBs.....20

19910-6403-001 Revision A, June 2012

Page 20: SNMP User's Guide

Supported MIBs

A Management Information Base (MIB) contains information required to manage a product clusterand the applications it runs. The exact syntax and nature of the parameters are described in the versionof each MIB that you are loading on your NMS.

SNMP MIB Objects

To use SNMP effectively, an administrator must become acquainted with the SNMP ManagementInformation Base (MIB), which defines all the values that SNMP is capable of reading or setting.

The SNMP MIB is arranged in a tree-structured fashion, similar in many ways to a disk directorystructure of files. The top level SNMP branch begins with the ISO "internet" directory, which containsfour main branches:

• The "mgmt" SNMP branch contains the standard SNMP objects usually supported (at least in part)by all network devices.

• The "private" SNMP branch contains those "extended" SNMP objects defined by network equipmentvendors.

• The "experimental" and "directory" SNMP branches, also defined within the "internet" root directory,are usually devoid of any meaningful data or objects.

The tree structure is an integral part of the SNMP standard; however the most pertinent parts of thetree are the "leaf" objects of the tree that provide actual management data about the device. Generally,SNMP leaf objects can be partitioned into two similar but slightly different types that reflect theorganization of the tree structure:

• Discrete MIB Objects. Discrete SNMP objects contain one piece of management data. The operatorhas to know only the name of the object and no other information. Discrete objects often representsummary values for a device, particularly useful for scanning information from the network forthe purposes of comparing network device performance. These objects are often distinguishedfrom "Table" objects by adding a ".0" (dot-zero) extension to their names. (If the ".0" extension isomitted from a leaf SNMP object name, it is always implied.)

• Table MIB Objects. Table SNMP objects contain multiple pieces of management data; they allowparallel arrays of information to be supported. These objects are distinguished from "Discrete"objects by requiring a "." (dot) extension to their names that distinguishes the particular value beingreferenced.

By convention, SNMP objects are always grouped in an "Entry" directory, within an object with a"Table" suffix. (The "ifDescr" object described above resides in the "ifEntry" directory contained inthe "ifTable" directory.) Several constraints are placed on SNMP objects as follows:

• Each object in the "Entry" directory of a table must contain the same number of elements asother objects in the same "Entry" directory, where instance numbers of all entries are the same.Table objects are always regarded as parallel arrays of data.

• When creating a new "Entry" object, SNMP requires that a value be associated with each tableentry in a single SNMP message (single PDU). This means that, to create a row in a table (usingan SNMP "set" command), a value must be specified for each element in the row.

• If a table row can be deleted, SNMP requires that at least one object in the entry has a controlelement that is documented to perform the table deletion. (This applies only if a row can bedeleted, which is not necessarily required of an SNMP table.)

20910-6403-001 Revision A, June 2012

Supported MIBs

Page 21: SNMP User's Guide

The "." (dot) extension is sometimes referred to as the "instance" number of an SNMP object. In thecase of "Discrete" objects, this instance number will be zero. In the case of "Table" objects, thisinstance number will be the index into the SNMP table.

MIB Object Access Values

Each SNMP object is defined to have a particular access, either "read-only", "read-write", or "write-only"that determines whether the user can read the object value, read and write the object (with a "set"command) or only write the object.

Before any object can be read or written, the SNMP community name must be known. These communitynames are configured into the system by the administrator, and can be viewed as passwords neededto gather SNMP data. Community names allow portions of the SNMP MIB, and object subsets, to bereferenced. The purpose of these values is to identify commonality between SNMP object sets, thoughit is common practice to make these community names obscure to limit access to SNMP capability byoutside users.

Compiling MIB Objects

One of the principal components of an SNMP manager is a "MIB Compiler", which allows new MIBobjects to be added to the management system. When a MIB is compiled into an SNMP manager, themanager is made aware of new objects that are supported by agents on the network. The concept issimilar to adding a new schema to a database. The agent is not affected by the MIB compilation (becausethe agent is already aware of its own objects). The act of compiling the MIB allows the manager toknow about the special objects supported by the agent and to access these objects as part of the standardobject set.

Typically, when a MIB is compiled into the system, the manager creates new folders or directoriesthat correspond to the objects. These folders or directories can typically be viewed with a "MIB Browser",which is a traditional SNMP management tool incorporated into virtually all network managementsystems. These new objects can often be alarmed or possibly modified to affect the performance of theremote agent.

MIB objects are documented in ASN.1 syntax. The user obtains ASN.1 definitions for a new piece ofnetwork equipment or new SNMP agent, transfers this file to the network management system, andruns the management system "MIB Compiler" to incorporate these definitions into the system. Virtuallyall agents support the RFC-1213 MIB definitions, and most agents support other definitions as well.

At a minimum, the following MIBs must be compiled into the management station that will be receivingtraps from the Policy systems in the network. The MIBs must be compiled in the following order:

1. tklc_toplevel.mib2. COMCOL-TC.mib3. PCRF-ALARM-MIB.mib4. NET-SNMP-MIB.txt5. NET-SNMP-AGENT-MIB.txt

Tekelec-supported MIBS are available on the installation media, or by contacting your Customer CareCenter.

MIBs are located on the running system in the following directories:

• /usr/TKLC/TKLCcomcol/cm5.14/prod/share/snmp/mib

COMCOL-TC.mib

21910-6403-001 Revision A, June 2012

Supported MIBs

Page 22: SNMP User's Guide

• /etc/camiant/snmp/mibs

PCRF-ALARM-MIB.mib

• /usr/share/snmp/mibs

NET-SNMP-MIB.txtNET-SNMP-AGENT-MIB.txt

• /usr/TKLC/plat/etc/snmp/mib

tklc_toplevel.mib

22910-6403-001 Revision A, June 2012

Supported MIBs

Page 23: SNMP User's Guide

Chapter

5Support for Traps

This chapter describes the Policy Managementfunctioning of alarms and traps with SNMP.

Topics:

• Alarms Overview.....24• Platform (31000-32700).....25• QBus Platform (70000-70999).....59• Policy Server Alarms (71000 - 89999).....66

23910-6403-001 Revision A, June 2012

Page 24: SNMP User's Guide

Alarms Overview

Alarms provide information about a system's operational condition, which an operator may need toact upon. Alarms have the following severities:

• Critical• Major• Minor

Policy Server alarms are generated by MPE or MRA servers based on the evaluation of componentstates and external factors. The servers communicate with each other in a cluster. Each server has adatabase with merge capabilities to replicate the alarm states to the CMP database. This informationis shown on the KPI dashboard or in detailed CMP reports.

As alarms and events are raised on an application or the platform, the SNMP subsystem issues acorresponding trap.

Alarms and Events have the following differences:

• Alarms:

• Are issued when a Fault is detected• Are latched until the Fault is removed (Are explicitly "set" and "cleared")• Have a Severity: Critical, Major, Minor• Will cause a trap

• Events

• Are issued with a Condition is detected (not a Fault)• Are not latched (Are not explicitly "set" or "cleared")• Do not have a Severity (the Severity is actually INFO)• Might cause a trap

Separate traps are sent upon raising an alarm and upon clearing an alarm.

Application traps contain the following variable bindings in addition to the sysOpTime and trapIDfields:

• comcolAlarmSrcNode - The node that originated the alarm• comcolAlarmNumber - The OID of the alarm and trap• comcolAlarmInstance - An instance is used when the trap is for a physical device such as

disk1, or connection diameterPeer 10.15.22.232:33119• comcolAlarmSeverity - Severity of the alarm: Critical (1), Major (2), Minor (3), Info (4), Clear

(5)• comcolAlarmText - A text object that defines the trap• comcolAlarmInfo - An extended text field that adds information to the trap text• comcolAlarmGroup - The group from which the trap originated (such as "PCRF" or "QP")

Refer to the Policy Management Troubleshooting Guide for more information about Policy Server alarmsand traps.

24910-6403-001 Revision A, June 2012

Support for Traps

Page 25: SNMP User's Guide

Note: If you encounter an alarm not in this document, contact the Tekelec Customer Care Center.

Platform (31000-32700)

This section provides information and recovery procedures for the Platform alarms, ranging from31000-32700.

Expanded List

31000 - S/W faultAlarm Type: SW

Description: Program impaired by s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and the given process.2. Contact Tekelec Customer Care Center.

31001 - S/W statusAlarm Type: SW

Description: Program status

Severity: Info

Recovery:

No action required.

31002 - Process watchdog failureAlarm Type: SW

Description: Process watchdog timed out

Severity: Minor

Recovery:

1. Export event history for the given server and the given process.2. Contact Tekelec Customer Care Center.

31003 - Tab thread watchdog failureAlarm Type: SW

Description: Tab thread watchdog timed out

25910-6403-001 Revision A, June 2012

Support for Traps

Page 26: SNMP User's Guide

Severity: Minor

Recovery:

1. Export event history for the given server and the given process.2. Contact Tekelec Customer Care Center.

31100 - Database replication faultAlarm Type: SW

Description: The Database replication process (inetsync) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and inetsync task.2. Contact Tekelec Customer Care Center.

31101 - Database replication to slave failureAlarm Type: REPL

Description: Database replication to a slave Database has failed

Severity: Critical

Recovery:

1. Check network connectivity between the affected servers.2. If there are no issues with network connectivity, contact the Tekelec Customer Care Center.

31102 - Database replication from master failureAlarm Type: REPL

Description: Database replication from a master Database has failed

Severity: Minor

Recovery:

1. Check network connectivity between the affected servers.2. If there are no issues with network connectivity, contact the Tekelec Customer Care Center.

31103- DB Replication update faultAlarm Type: REPL

Description: Database replication process cannot apply update to DB

Severity: Minor

Recovery:

1. Export event history for the given server and inetsync task.

26910-6403-001 Revision A, June 2012

Support for Traps

Page 27: SNMP User's Guide

2. Contact Tekelec Customer Care Center.

31104 - DB Replication latency over thresholdAlarm Type: REPL

Description: Database replication latency has exceeded thresholds

Severity: Minor

Recovery:

1. If this alarm is raised occasionally for short time periods (a couple of minutes or less), it may indicatenetwork congestion or spikes of traffic pushing servers beyond their capacity. Considerre-engineering network capacity or subscriber provisioning.

2. If this alarm does not clear after a couple of minutes, contact Tekelec Customer Care Center.

31105 - Database merge faultAlarm Type: SW

Description: The database merge process (inetmerge) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and inetmerge task.2. Contact Tekelec Customer Care Center.

31106 - Database merge to parent failureAlarm Type: COLL

Description: Database merging to the parent Merge Node has failed

Severity: Minor

Recovery:

1. Check network connectivity between the affected servers.2. If there are no issues with network connectivity, contact the Tekelec Customer Care Center.

31107 - Database merge from child failureAlarm Type: COLL

Description: Database merging from a child Source Node has failed

Severity: Major

Recovery:

1. Check network connectivity between the affected servers.2. If there are no issues with network connectivity, contact the Tekelec Customer Care Center.

27910-6403-001 Revision A, June 2012

Support for Traps

Page 28: SNMP User's Guide

31108 - Database merge latency over thresholdAlarm Type: COLL

Description: Database Merge latency has exceeded thresholds

Severity: Minor

Recovery:

1. If this alarm is raised occasionally for short time periods (a couple of minutes or less), it may indicatenetwork congestion or spikes of traffic pushing servers beyond their capacity. Considerre-engineering network capacity or subscriber provisioning.

2. If this alarm does not clear after a couple of minutes, contact Tekelec Customer Care Center

31109 - Topology config errorAlarm Type: DB

Description: Topology is configured incorrectly

Severity: Minor

Recovery:

1. This alarm may occur during initial installation and configuration of a server. No action is necessaryat that time.

2. If this alarm occurs after successful initial installation and configuration of a server, contact theTekelec Customer Care Center.

31110 - Database audit faultAlarm Type: SW

Description: The Database service process (idbsvc) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and idbsvc task.2. Contact Tekelec Customer Care Center.

31111 - Database merge audit in progressAlarm Type: COLL

Description: Database Merge Audit between mate nodes in progress

Severity: Minor

Recovery:

No action required.

28910-6403-001 Revision A, June 2012

Support for Traps

Page 29: SNMP User's Guide

31112 - DB replication update log transfer timed outAlarm Type: REPL

Description: DB Replicated data may not have transferred in the time allotted.

Severity: Minor

Recovery:

No action required. Contact Tekelec Customer Care Center if this occurs frequently.

31113 - DB replication manually disabledAlarm Type: REPL

Description: DB Replication Manually Disabled

Severity: Minor

Recovery:

No action required.

31114 - DB replication over SOAP has failedAlarm Type: REPL

Description: Database replication of configuration data via SOAP has failed

Severity: Minor

Recovery:

1. Check network connectivity between the affected servers.2. If there are no issues with network connectivity, contact the Tekelec Customer Care Center.

31115 - Database service faultAlarm Type: SW

Description: The Database service process (idbsvc) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and idbsvc task.2. Contact Tekelec Customer Care Center.

31116 - Excessive shared memoryAlarm Type: MEM

Description: The amount of shared memory consumed exceeds configured thresholds

Severity: Major

29910-6403-001 Revision A, June 2012

Support for Traps

Page 30: SNMP User's Guide

Recovery:

Contact Tekelec Customer Care Center.

31117 - Low disk freeAlarm Type: DISK

Description: The amount of free disk is below configured thresholds

Severity: Major

Recovery:

1. Remove unnecessary or temporary files from partitions.2. If there are no files known to be unneeded, contact Tekelec Customer Care Center.

31118 - Database disk store faultAlarm Type: DISK

Description: Writing the database to disk failed

Severity: Minor

Recovery:

1. Remove unnecessary or temporary files from partitions.2. If there are no files known to be unneeded, contact Tekelec Customer Care Center.

31119 - Database updatelog overrunAlarm Type: DB

Description: The Database update log was overrun increasing risk of data loss

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31120 - Database updatelog write faultAlarm Type: DB

Description: A Database change cannot be stored in the updatelog

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

30910-6403-001 Revision A, June 2012

Support for Traps

Page 31: SNMP User's Guide

31121 - Low disk free early warningAlarm Type: DISK

Description: The amount of free disk is below configured early warning thresholds

Severity: Minor

Recovery:

1. Remove unnecessary or temporary files from partitions that are greater than 80% full.2. If there are no files known to be unneeded, contact Tekelec Customer Care Center.

31122 - Excessive shared memory early warningAlarm Type: MEM

Description: The amount of shared memory consumed exceeds configured early warning thresholds

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31123 - Database replication audit command completeAlarm Type: REPL

Description: A DB replication audit command completed

Severity: Info

Recovery:

No action required.

31124 - Database replication audit command errorAlarm Type: REPL

Description: A DB replication audit command detected errors

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31125 - Database durability degradedAlarm Type: REPL

Description: Database durability has dropped below configured durability level

Severity: Major

Recovery:

31910-6403-001 Revision A, June 2012

Support for Traps

Page 32: SNMP User's Guide

1. Check configuration of all servers, and check for connectivity problems between server addresses.2. If the problem persists, contact Tekelec Customer Care Center.

31126- Audit blockedAlarm Type: SW

Description: Site Audit Controls blocked an inter-site replication audit due to the number in progressper configuration.

Severity: Major

Recovery:

Contact Tekelec Customer Care Center.

31130 - Network health warningAlarm Type: NET

Description: Network health issue detected

Severity: Minor

Recovery:

1. Check configuration of all servers, and check for connectivity problems between server addresses.2. If the problem persists, contact Tekelec Customer Care Center.

31140 - Database perl faultAlarm Type: SW

Description: Perl interface to Database is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31145 - Database SQL faultAlarm Type: SW

Description: SQL interface to Database is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server, and Imysqld task.2. Contact Tekelec Customer Care Center.

32910-6403-001 Revision A, June 2012

Support for Traps

Page 33: SNMP User's Guide

31146- DB mastership faultAlarm Type: SW

Description: DB replication is impaired due to no mastering process (inetrep/inetrep).

Severity: Major

Recovery:

1. Export event history for the given server.2. Contact Tekelec Customer Care Center.

31147- DB upsynclog overrunAlarm Type: SW

Description: UpSyncLog is not big enough for (WAN) replication.

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31200 - Process management faultAlarm Type: SW

Description: The process manager (procmgr) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server, all processes.2. Contact Tekelec Customer Care Center.

31201 - Process not runningAlarm Type: PROC

Description: A managed process cannot be started or has unexpectedly terminated

Severity: Major

Recovery:

Contact Tekelec Customer Care Center.

31202 - Unkillable zombie processAlarm Type: PROC

Description: A zombie process exists that cannot be killed by procmgr. procmgr will no longer managethis process.

33910-6403-001 Revision A, June 2012

Support for Traps

Page 34: SNMP User's Guide

Severity: Major

Recovery:

1. If the process does not exit, it may be necessary to reboot the server to eliminate the zombie process.2. Contact Tekelec Customer Care Center.

31206 - Process mgmt monitoring faultAlarm Type: SW

Description: The process manager monitor (pm.watchdog) is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31207 - Process resource monitoring faultAlarm Type: SW

Description: The process resource monitor (ProcWatch) is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31208 - IP port server faultAlarm Type: SW

Description: The run environment port mapper (re.portmap) is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31209 - Hostname lookup failedAlarm Type: SW

Description: Unable to resolve a hostname specified in the NodeInfo table

Severity: Minor

Recovery:

1. This typically indicate a DNS Lookup failure. Verify all server hostnames are correct in the GUIconfiguration on the server generating the alarm.

2. If the problem persists, contact Tekelec Customer Care Center.

34910-6403-001 Revision A, June 2012

Support for Traps

Page 35: SNMP User's Guide

31213 - Process scheduler faultAlarm Type: SW

Description: The process scheduler (ProcSched/runat) is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31214 - Scheduled process faultAlarm Type: PROC

Description: A scheduled process cannot be executed or abnormally terminated

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31215 - Process resources exceededAlarm Type: SW

Description: A process is consuming excessive system resources

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31216 - SysMetric configuration errorAlarm Type: SW

Description: A SysMetric Configuration table contains invalid data

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31220 - HA configuration monitor faultAlarm Type: SW

Description: The HA configuration monitor is impaired by a s/w fault

Severity: Minor

Recovery:

35910-6403-001 Revision A, June 2012

Support for Traps

Page 36: SNMP User's Guide

Contact Tekelec Customer Care Center.

31221 - HA alarm monitor faultAlarm Type: SW

Description: The high availability alarm monitor is impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31222 - HA not configuredAlarm Type: HA

Description: High availability is disabled due to system configuration

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31223 - HA Heartbeat transmit failureAlarm Type: HA

Description: The high availability monitor failed to send heartbeat

Severity: Major

Recovery:

1. This alarm clears automatically when the server successfully registers for HA heartbeating.2. If this alarm does not clear after a couple minutes, contact Tekelec Customer Care Center.

31224 - HA configuration errorAlarm Type: HA

Description: High availability configuration error

Severity: Major

Recovery:

Contact the Tekelec Customer Care Center.

31225 - HA service start failureAlarm Type: HA

Description: The high availability service failed to start

36910-6403-001 Revision A, June 2012

Support for Traps

Page 37: SNMP User's Guide

Severity: Major

Recovery:

1. This alarm clears automatically when the HA daemon is successfully started.2. If this alarm does not clear after a couple minutes, contact Tekelec Customer Care Center.

31226 - HA availability status degradedAlarm Type: HA

Description: The high availability status is degraded due to raised alarms

Severity: Major

Recovery:

1. View alarms dashboard for other active alarms on this server.2. Follow corrective actions for each individual alarm on the server to clear them.3. If the problem persists, contact Tekelec Customer Care Center.

31227 - HA availability status failedAlarm Type: HA

Description: The high availability status is failed due to raised alarms

Severity: Critical

Recovery:

1. View alarms dashboard for other active alarms on this server.2. Follow corrective actions for each individual alarm on the server to clear them.3. If the problem persists, contact Tekelec Customer Care Center.

31228 - HA standby offlineAlarm Type: HA

Description: High availability standby server is offline

Severity: Critical

Severity: Major

Recovery:

1. If loss of communication between the active and standby servers is caused intentionally bymaintenance activity, alarm can be ignored; it clears automatically when communication is restoredbetween the two servers.

2. If communication fails at any other time, look for network connectivity issues and/or contactTekelec Customer Care Center.

37910-6403-001 Revision A, June 2012

Support for Traps

Page 38: SNMP User's Guide

31229 - HA score changedAlarm Type: HA

Description: High availability health score changed

Severity: Info

Recovery:

Status message - no action required.

31230 - Recent alarm processing faultAlarm Type: SW

Description: The recent alarm event manager (raclerk) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and raclerk task.2. Contact Tekelec Customer Care Center.

31231 - Platform alarm agent faultAlarm Type: SW

Description: The platform alarm agent impaired by a s/w fault

Severity: Minor

Recovery:

Contact Tekelec Customer Care Center.

31232- Late heartbeat warningAlarm Type: SW

Description: No HA heartbeat received from standby server.

Severity: Minor

Recovery:

No action required; this is a warning and can be due to transient conditions. If there continues tobe no heartbeat from the server, alarm 31228 occurs.

31240 - Measurements collection faultAlarm Type: SW

Description: The measurments collector (statclerk) is impaired by a s/w fault

Severity: Minor

38910-6403-001 Revision A, June 2012

Support for Traps

Page 39: SNMP User's Guide

Recovery:

1. Export event history for the given server and statclerk task.2. Contact Tekelec Customer Care Center.

31250 - RE port mapping faultAlarm Type: SW

Description: The IP service port mapper (re.portmap) is impaired by a s/w fault

Severity: Minor

Recovery:

This typically indicate a DNS Lookup failure. Verify all server hostnames are correct in the GUIconfiguration on the server generating the alarm.

31260 - Database SNMP AgentAlarm Type: SW

Description: The Database SNMP agent (snmpIdbAgent) is impaired by a s/w fault

Severity: Minor

Recovery:

1. Export event history for the given server and all processes.2. Contact Tekelec Customer Care Center.

31270 - Logging outputAlarm Type: SW

Description: Logging output set to Above Normal

Severity: Minor

Recovery:

Extra diagnostic logs are being collected, potentially degrading system performance. ContactTekelec Customer Care Center.

31280 - HA Active to Standby transitionAlarm Type: HA

Description: HA active to standby activity transition

Severity: Info

Recovery:

1. If this alarm occurs during routine maintenance activity, it may be ignored.2. Otherwise, contact Tekelec Customer Care Center.

39910-6403-001 Revision A, June 2012

Support for Traps

Page 40: SNMP User's Guide

31281 - HA Standby to Active transitionAlarm Type: HA

Description: HA standby to active activity transition

Severity: Info

Recovery:

1. If this alarm occurs during routine maintenance activity, it may be ignored.2. Otherwise, contact Tekelec Customer Care Center.

32113 - Uncorrectable ECC memory errorAlarm Type: TPD

Description: This alarm indicates that chipset has detected an uncorrectable (multiple-bit) memoryerror that the ECC (Error-Correcting Code) circuitry in the memory is unable to correct.

Severity: Critical

Recovery

Contact the Tekelec Customer Care Center to request hardware replacement.

32114 - SNMP get failureAlarm Type: TPD

Description: The server failed to receive SNMP information from the switch.

Severity: Critical

Recovery

1. Use the following command to verify the switch is active: ping switch1A/B (this requirescommand line access).

2. If the problem persists, contact the Tekelec Customer Care Center.

32300 – Server fan failureAlarm Type: TPD

Description: This alarm indicates that a fan on the application server is either failing or has failedcompletely. In either case, there is a danger of component failure due to overheating.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32301 - Server internal disk errorAlarm Type: TPD

40910-6403-001 Revision A, June 2012

Support for Traps

Page 41: SNMP User's Guide

Description: This alarm indicates the server is experiencing issues replicating data to one or more ofits mirrored disk drives. This could indicate that one of the server’s disks has either failed or isapproaching failure.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32302 – Server RAID disk errorAlarm Type: TPD

Description: This alarm indicates that the offboard storage server had a problem with its hardwaredisks.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32303 - Server Platform errorAlarm Type: TPD

Description: This alarm indicates an error such as a corrupt system configuration or missing files.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32304 - Server file system errorAlarm Type: TPD

Description: This alarm indicates unsuccessful writing to at least one of the server’s file systems.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32305 - Server Platform process errorAlarm Type: TPD

Description: This alarm indicates that either the minimum number of instances for a required processare not currently running or too many instances of a required process are running.

Severity: Major

Recovery

41910-6403-001 Revision A, June 2012

Support for Traps

Page 42: SNMP User's Guide

Contact the Tekelec Customer Care Center.

32306 – Server RAM shortage errorAlarm Type: TPD

Not Implemented. This alarm is generated by the MPS syscheck software package and is not part ofthe distribution.

Severity: Major

1. Refer to MPS-specific documentation for information regarding this alarm.2. Contact the Tekelec Customer Care Center.

32307 - Server swap space shortage failureAlarm Type: TPD

Description: This alarm indicates that the server’s swap space is in danger of being depleted. This isusually caused by a process that has allocated a very large amount of memory over time.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32308 - Server provisioning network errorAlarm Type: TPD

Description: This alarm indicates that the connection between the server’s ethernet interface and thecustomer network is not functioning properly.

Severity: Major

Recovery

1. Verify that a customer-supplied cable labeled TO CUSTOMER NETWORK is securely connectedto the appropriate server. Follow the cable to its connection point on the local network and verifythis connection is also secure.

2. Test the customer-supplied cable labeled TO CUSTOMER NETWORK with an Ethernet Line Tester.If the cable does not test positive, replace it.

3. Have your network administrator verify that the network is functioning properly.4. If no other nodes on the local network are experiencing problems and the fault has been isolated

to the server or the network administrator is unable to determine the exact origin of the problem,contact the Tekelec Customer Care Center.

32312 - Server disk space shortage errorAlarm Type: TPD

Description: This alarm indicates that one of the following conditions has occurred:

42910-6403-001 Revision A, June 2012

Support for Traps

Page 43: SNMP User's Guide

• A filesystem has exceeded a failure threshold, which means that more than 90% of the availabledisk storage has been used on the filesystem.

• More than 90% of the total number of available files have been allocated on the filesystem.• A filesystem has a different number of blocks than it had when installed.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32313 - Server default route network errorAlarm Type: TPD

Description: This alarm indicates that the default network route of the server is experiencing a problem.

CAUTION: When changing the network routing configuration of the server, verify thatthe modifications will not impact the method of connectivity for the current login session.The route information must be entered correctly and set to the correct values. Incorrectlymodifying the routing configuration of the server may result in total loss of remote networkaccess.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32314 - Server temperature errorAlarm Type: TPD

Description: The internal temperature within the server is unacceptably high.

Severity: Major

Recovery

1. Ensure that nothing is blocking the fan's intake. Remove any blockage.2. Verify that the temperature in the room is normal. If it is too hot, lower the temperature in the room

to an acceptable level.

Note: Be prepared to wait the appropriate period of time before continuing with the next step.Conditions need to be below alarm thresholds consistently for the alarm to clear. It may take aboutten minutes after the room returns to an acceptable temperature before the alarm cleared.

3. If the problem has not been resolved, contact the Tekelec Customer Care Center.

32315 – Server mainboard voltage errorAlarm Type: TPD

Description: This alarm indicates that one or more of the monitored voltages on the server mainboardhave been detected to be out of the normal expected operating range.

43910-6403-001 Revision A, June 2012

Support for Traps

Page 44: SNMP User's Guide

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32316 – Server power feed errorAlarm Type: TPD

Description: This alarm indicates that one of the power feeds to the server has failed. If this alarmoccurs in conjunction with any Breaker Panel alarm, there might be a problem with the breaker panel.

Severity: Major

Recovery

1. Verify that all the server power feed cables to the server that is reporting the error are securelyconnected.

2. Check to see if the alarm has cleared

• If the alarm has been cleared, the problem is resolved.• If the alarm has not been cleared, continue with the next step.

3. Follow the power feed to its connection on the power source. Ensure that the power source is ONand that the power feed is properly secured.

4. Check to see if the alarm has cleared

• If the alarm has been cleared, the problem is resolved.• If the alarm has not been cleared, continue with the next step.

5. If the power source is functioning properly and the wires are all secure, have an electrician checkthe voltage on the power feed.

6. Check to see if the alarm has cleared

• If the alarm has been cleared, the problem is resolved.• If the alarm has not been cleared, continue with the next step.

7. If the problem has not been resolved, contact the Tekelec Customer Care Center.

32317 - Server disk health test errorAlarm Type: TPD

Description: Either the hard drive has failed or failure is imminent.

Severity: Major

Recovery

1. Perform the recovery procedures for the other alarms that accompany this alarm.2. If the problem has not been resolved, contact the Tekelec Customer Care Center.

44910-6403-001 Revision A, June 2012

Support for Traps

Page 45: SNMP User's Guide

32318 - Server disk unavailable errorAlarm Type: TPD

Description: The smartd service is not able to read the disk status because the disk has other problemsthat are reported by other alarms. This alarm appears only while a server is booting.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32319 – Device errorAlarm Type: TPD

This alarm indicates that the offboard storage server had a problem with its disk volume filling up.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32320 – Device interface errorAlarm Type: TPD

Description: This alarm indicates that the IP bond is either not configured or down.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32321 – Correctable ECC memory errorAlarm Type: TPD

Description: This alarm indicates that chipset has detected a correctable (single-bit) memory errorthat has been corrected by the ECC (Error-Correcting Code) circuitry in the memory.

Severity: Major

Recovery

No recovery necessary. If the condition persists, contact the Tekelec Customer Care Center to requesthardware replacement.

32322 – Power Supply A errorAlarm Type: TPD

Description: This alarm indicates that power supply 1 (feed A) has failed.

45910-6403-001 Revision A, June 2012

Support for Traps

Page 46: SNMP User's Guide

Severity: Major

Recovery

1. Verify that nothing is obstructing the airflow to the fans of the power supply.2. If the problem persists, contact the Tekelec Customer Care Center.

32323 – Power Supply B errorAlarm Type: TPD

Description: This alarm indicates that power supply 2 (feed B) has failed.

Severity: Major

Recovery

1. Verify that nothing is obstructing the airflow to the fans of the power supply.2. If the problem persists, contact the Tekelec Customer Care Center.

32324 – Breaker panel feed errorAlarm Type: TPD

Description: This alarm indicates that the server is not receiving information from the breaker panelrelays.

Severity: Major

Recovery

1. Verify that the same alarm is displayed by multiple servers:

• If this alarm is displayed by only one server, the problem is most likely to be with the cable orthe server itself. Look for other alarms that indicate a problem with the server and perform therecovery procedures for those alarms first.

• If this alarm is displayed by multiple servers, go to the next step.

2. Verify that the cables that connect the servers to the breaker panel are not damaged and are securelyfastened to both the Alarm Interface ports on the breaker panel and to the serial ports on bothservers.

3. If the problem has not been resolved, call the Tekelec Customer Care Center to request that thebreaker panel be replaced.

32325 – Breaker panel breaker errorAlarm Type: TPD

Description: This alarm indicates that a power fault has been identified by the breaker panel.

Severity: Major

Recovery

1. Verify that the same alarm is displayed by multiple servers:

46910-6403-001 Revision A, June 2012

Support for Traps

Page 47: SNMP User's Guide

If this alarm is displayed by only one server, the problem is most likely to be with the cable orthe server itself. Look for other alarms that indicate a problem with the server and perform therecovery procedures for those alarms first.

• If this alarm is displayed by multiple servers, go to the next step.

2. Look at the breaker panel assignments and verify that the corresponding LED in the PWR BUS Agroup and the PWR BUS B group is illuminated Green.

If one of the LEDs in the PWR BUS A group or the PWR BUS B group is illuminated Red, a problemhas been detected with the corresponding input power feed. Contact the Tekelec Customer CareCenter.

3. Check the BRK FAIL LEDs for BUS A and for BUS B.

• If one of the BRK FAIL LEDs is illuminated Red, then one or more of the respective InputBreakers has tripped. (A tripped breaker is indicated by the toggle located in the center position.)Perform the following steps to repair this issue:

a) For all tripped breakers, move the breaker down to the open (OFF) position and then back upto the closed (ON) position.

b) After all the tripped breakers have been reset, check the BRK FAIL LEDs again. If one of theBRK FAIL LEDs is still illuminated Red, contact the Tekelec Customer Care Center .

• If all of the BRK FAIL LEDs and all the LEDs in the PWR BUS A group and the PWR BUS Bgroup are illuminated Green, go to Step 4.

4. If the problem has not been resolved, contact the Tekelec Customer Care Center.

32326 – Breaker panel monitoring errorAlarm Type: TPD

Description: This alarm indicates a failure in the hardware and/or software that monitors the breakerpanel. This could mean there is a problem with the file I/O libraries, the serial device drivers, or theserial hardware itself.

Note: When this alarm occurs, the system is unable to monitor the breaker panel for faults. Thus, ifthis alarm is detected, it is imperative that the breaker panel be carefully examined for the existenceof faults. The LEDs on the breaker panel will be the only indication of the occurrence of either alarm

• 32324-Breaker Panel Feed Error or• 32325-Breaker Panel Breaker Error

until the Breaker Panel Monitoring Error has been corrected.

Severity: Major

Recovery

1. Verify that the same alarm is displayed by multiple servers:

• If this alarm is displayed by only one server, the problem is most likely to be with the cable orthe server itself. Look for other alarms that indicate a problem with the server and perform therecovery procedures for those alarms first.

• If this alarm is displayed by multiple servers, go to the next step.

47910-6403-001 Revision A, June 2012

Support for Traps

Page 48: SNMP User's Guide

2. Verify that both ends of the labeled serial cables are secured properly (for locations of serial cables,see the appropriate hardware manual).

3. If the alarm has not been cleared, contact the Tekelec Customer Care Center.

32327 – Server HA Keepalive errorAlarm Type: TPD

Description: This alarm indicates that heartbeat process has detected that it has failed to receive aheartbeat packet within the timeout period.

Severity: Major

Recovery

1. Determine if the mate server is currently down and bring it up if possible.2. Determine if the keepalive interface is down.3. Determine if heartbeart is running (service TKLCha status).

Note: This step may require command line ability.

4. Contact the Tekelec Customer Care Center.

32328 – DRBD is unavailableAlarm Type: TPD

Description: This alarm indicates that DRBD is not functioning properly on the local server. The DRBDstate (disk state, node state, and/or connection state) indicates a problem.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32329 – DRBD is not replicatingAlarm Type: TPD

Description: This alarm indicates that DRBD is not replicating to the peer server. Usually this indicatesthat DRBD is not connected to the peer server. It is possible that a DRBD Split Brain has occurred.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32330 – DRBD peer problemAlarm Type: TPD

Description: This alarm indicates that DRBD is not functioning properly on the peer server. DRBD isconnected to the peer server, but the DRBD state on the peer server is either unknown or indicates aproblem.

48910-6403-001 Revision A, June 2012

Support for Traps

Page 49: SNMP User's Guide

Severity: Major

Recovery

Contact the Customer Care Center.

32331 – HP disk problemAlarm Type: TPD

Description: This major alarm indicates that there is an issue with either a physical or logical disk inthe HP disk subsystem. The message will include the drive type, location, slot and status of the drivethat has the error.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32332 – HP Smart Array controller problemAlarm Type: TPD

Description: This major alarm indicates that there is an issue with an HP disk controller. The messagewill include the slot location, the component on the controller that has failed, and status of the controllerthat has the error.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32333 – HP hpacucliStatus utility problemAlarm Type: TPD

Description: This major alarm indicates that there is an issue with the process that caches the HP disksubsystem status. This usually means that the hpacucliStatus daemon is either not running, or hung.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32334 - Multipath device access link problemAlarm Type: TPD

Description: One or more "access paths" of a multipath device are failing or are not healthy, or themultipath device does not exist.

Severity: Major

Recovery

49910-6403-001 Revision A, June 2012

Support for Traps

Page 50: SNMP User's Guide

Contact the Tekelec Customer Care Center.

32335 - Switch link down errorAlarm Type: TPD

Description: The link is down.

Severity: Major

Within this trap are two bind variables, the OIDs of which are:

• 1.3.6.1.2.1.1.5 <sysname>, where <sysname> is the name of the switch where the failure occurred.• 1.3.6.1.2.1.2.2.1.1 <link index>, where <link index> is the index of the failed link.

Recovery

1. Verify the cabling between the port and the remote side.2. Verify networking on the remote end.3. If the problem persists, contact the Tekelec Customer Care Center who should verify port settings

on both the server and the switch.

32336– Half Open TCP Socket LimitAlarm Type: TPD

This alarm indicates that the number of half open TCP sockets has reached the major threshold. Thisproblem is caused by a remote system failing to complete the TCP 3-way handshake.

Severity: Major

Recovery

Contact the Tekelec Customer Care Center.

32403 – PM&C backup failedAlarm Type: PM&C

The PM&C application has a failure that needs to be investigated.

Severity: Major

1. Attempt a manual backup using the PM&C GUI.2. If the problems persists, contact the Tekelec Customer Care Center.

32500 – Server disk space shortage warningAlarm Type: TPD

Description: This alarm indicates that one of the following conditions has occurred:

• A file system has exceeded a warning threshold, which means that more than 80% (but less than90%) of the available disk storage has been used on the file system.

• More than 80% (but less than 90%) of the total number of available files have been allocated on thefile system.

50910-6403-001 Revision A, June 2012

Support for Traps

Page 51: SNMP User's Guide

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32501 – Server application process errorAlarm Type: TPD

Description: This alarm indicates that either the minimum number of instances for a required processare not currently running or too many instances of a required process are running.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32502 – Server hardware configuration errorAlarm Type: TPD

Description: This alarm indicates that one or more of the server’s hardware components are not incompliance with Tekelec specifications (refer to the appropriate hardware manual).

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32503 – Server RAM shortage warningAlarm Type: TPD

Description: This alarm is generated by the MPS syscheck software package and is not part of theTPD distribution.

Severity: Minor

Recovery

1. Refer to MPS-specific documentation for information regarding this alarm.2. Contact the Tekelec Customer Care Center.

32505 – Server swap space shortage warningAlarm Type: TPD

Description: This alarm indicates that the swap space available on the server is less than expected.This is usually caused by a process that has allocated a very large amount of memory over time.

Note: For this alarm to clear, the underlying failure condition must be consistently undetected for anumber of polling intervals. Therefore, the alarm may continue to be reported for several minutesafter corrective actions are completed.

51910-6403-001 Revision A, June 2012

Support for Traps

Page 52: SNMP User's Guide

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32506 – Server default router not definedAlarm Type: TPD

Description: This alarm indicates that the default network route is either not configured or the currentconfiguration contains an invalid IP address or hostname.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32507 – Server temperature warningAlarm Type: TPD

Description: This alarm indicates that the internal temperature within the server is outside of thenormal operating range. A server Fan Failure may also exist along with the Server TemperatureWarning.

Severity: Minor

Recovery

1. Ensure that nothing is blocking the fan's intake. Remove any blockage.2. Verify that the temperature in the room is normal. If it is too hot, lower the temperature in the room

to an acceptable level.

Note: Be prepared to wait the appropriate period of time before continuing with the next step.Conditions need to be below alarm thresholds consistently for the alarm to clear. It may take aboutten minutes after the room returns to an acceptable temperature before the alarm cleared.

3. Replace the filter (refer to the appropriate hardware manual).

Note: Be prepared to wait the appropriate period of time before continuing with the next step.Conditions need to be below alarm thresholds consistently for the alarm to clear. It may take aboutten minutes after the filter is replaced before the alarm cleared.

4. If the problem has not been resolved, contact the Tekelec Customer Care Center.

32508 – Server core file detectedAlarm Type: TPD

Description: This alarm indicates that an application process has failed and debug information isavailable.

Severity: Minor

Recovery

52910-6403-001 Revision A, June 2012

Support for Traps

Page 53: SNMP User's Guide

Contact the Tekelec Customer Care Center.

32509 – Server NTP Daemon not synchronizedAlarm Type: TPD

Description: This alarm indicates that the NTP daemon (background process) has been unable tolocate a server to provide an acceptable time reference for synchronization.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32510 – CMOS battery voltage lowAlarm Type: TPD

Description: The presence of this alarm indicates that the CMOS battery voltage has been detected tobe below the expected value. This alarm is an early warning indicator of CMOS battery end-of-lifefailure which will cause problems in the event the server is powered off.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32511 – Server disk self test warningAlarm Type: TPD

Description: A non-fatal disk issue (such as a sector cannot be read) exists.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32512 – Device warningAlarm Type: TPD

Description: This alarm indicates that either we are unable to perform an snmpget command on theconfigured SNMP OID or the value returned failed the specified comparison operation.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32513 – Device interface warningAlarm Type: TPD

53910-6403-001 Revision A, June 2012

Support for Traps

Page 54: SNMP User's Guide

Description: This alarm can be generated by either an SNMP trap or an IP bond error.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32514 – Server reboot watchdog initiatedAlarm Type: TPD

Description: This alarm indicates that the hardware watchdog was not strobed by the software andso the server rebooted the server. This applies to only the last reboot and is only supported on a T1100application server.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32515 – Server HA failover inhibitedAlarm Type: TPD

Description: This alarm indicates that the server has been inhibited and therefore HA failover isprevented from occurring.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32516 – Server HA Active to Standby transitionAlarm Type: TPD

Description: This alarm indicates that the server is in the process of transitioning HA state from Activeto Standby.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32517 – Server HA Standby to Active transitionAlarm Type: TPD

Description: This alarm indicates that the server is in the process of transitioning HA state fromStandby to Active.

Severity: Minor

Recovery

54910-6403-001 Revision A, June 2012

Support for Traps

Page 55: SNMP User's Guide

Contact the Tekelec Customer Care Center.

32518 – Platform Health Check failureAlarm Type: TPD

Description: This alarm is used to indicate a configuration error.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32519 – NTP Offset Check failureAlarm Type: TPD

Description: This minor alarm indicates that time on the server is outside the acceptable range (oroffset) from the NTP server. The Alarm message will provide the offset value of the server from theNTP server and the offset limit that the application has set for the system.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32520 – NTP Stratum Check failureAlarm Type: TPD

Description: This alarm indicates that NTP is syncing to a server, but the stratum level of the NTPserver is outside of the acceptable limit. The Alarm message will provide the stratum value of the NTPserver and the stratum limit that the application has set for the system.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32521 – SAS Presence Sensor MissingAlarm Type: TPD

Description: This alarm indicates that the T1200 server drive sensor is not working.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center to get a replacement server.

32522 – SAS Drive MissingAlarm Type: TPD

55910-6403-001 Revision A, June 2012

Support for Traps

Page 56: SNMP User's Guide

Description: This alarm indicates that the number of drives configured for this server is not beingdetected.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center to determine whether the issue is with a failed drive orfailed configuration.

32523 – DRBD failover busyAlarm Type: TPD

Description: This alarm indicates that a DRBD sync is in progress from the peer server to the localserver. The local server is not ready to act as the primary DRBD node, since it’s data is not up to date.

Severity: Minor

Recovery

A DRBD sync should not take more than 15 minutes to complete. Please wait for approximately20 minutes, and then check if the DRBD sync has completed. If the alarm persists longer than thistime period, contact the Tekelec Customer Care Center.

32524 – HP disk resyncAlarm Type: TPD

Description: This minor alarm indicates that the HP disk subsystem is currently resynchronizing aftera failed or replaced drive, or some other change in the configuration of the HP disk subsystem. Theoutput of the message will include the disk that is resynchronizing and the percentage complete. Thisalarm should eventually clear once the resync of the disk is completed. The time it takes for this isdependant on the size of the disk and the amount of activity on the system.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32525 – Telco Fan WarningAlarm Type: TPD

Description: This alarm indicates that the Telco switch has detected an issue with an internal fan.

Severity: Minor

Recovery

1. Contact the Tekelec Customer Care Center to get a replacement switch. Verify the ambient airtemperature around the switch is as low as possible until the switch is replaced.

2. Tekelec Customer Care Center personnel can perform an snmpget command or log into the switchto get detailed fan status information.

56910-6403-001 Revision A, June 2012

Support for Traps

Page 57: SNMP User's Guide

32526 – Telco Temperature WarningAlarm Type: TPD

Description: This alarm indicates that the Telco switch has detected the internal temperature hasexceeded the threshold.

Severity: Minor

Recovery

1. Lower the ambient air temperature around the switch as low as possible.2. If problem persists, contact the Tekelec Customer Care Center.

32527 – Telco Power Supply WarningAlarm Type: TPD

Description: This alarm indicates that the Telco switch has detected that one of the duplicate powersupplies has failed.

Severity: Minor

Recovery

1. Verify breaker wasn't tripped.2. If breaker is still good and problem persists, contact the Tekelec Customer Care Center who can

perform a snmpget command or log into the switch to determine which power supply is failing.If the power supply is bad, the switch must be replaced.

32528 – Invalid BIOS valueAlarm Type: TPD

Description: This alarm indicates that the HP server has detected that one of the setting for either theembedded serial port or the virtual serial port is incorrect.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32529– Server Kernel Dump File DetectedAlarm Type: TPD

Description: This alarm indicates that the kernel has crashed and debug information is available.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

57910-6403-001 Revision A, June 2012

Support for Traps

Page 58: SNMP User's Guide

32530– TPD Upgrade FailedAlarm Type: TPD

Description: This alarm indicates that a TPD upgrade has failed.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32531– Half Open Socket Warning LimitAlarm Type: TPD

This alarm indicates that the number of half open TCP sockets has reached the major threshold. Thisproblem is caused by a remote system failing to complete the TCP 3-way handshake.

Severity: Minor

Recovery

Contact the Tekelec Customer Care Center.

32532– Server Upgrade Pending Accept/RejectAlarm Type: TPD

This alarm indicates that an upgrade occurred but has not been accepted or rejected yet.

Severity: Minor

Recovery

Follow the steps in the application's upgrade procedure for accepting or rejecting the upgrade.

32603 – PM&C backup to remote server failedAlarm Type: PM&C

The PMAC application has a failure that needs to be investigated.

Severity: Minor

1. Verify that the remote server is operational.2. Verify that the primary PMAC can ping the remote server.3. Attempt a manual backup to remote server using the PMAC GUI.4. If the problems persists, contact the Tekelec Customer Care Center.

58910-6403-001 Revision A, June 2012

Support for Traps

Page 59: SNMP User's Guide

QBus Platform (70000-70999)

The QBus Platform (QP) software provides an execution environment for Java-based applications,which are the Multiprotocol Routing Agent (MRA), Multimedia Policy Engine (MPE), or the CamiantManagement Platform (CMP). QP provides common interfaces into databases, event logging, SNMP,and cluster state. Two blades in the cluster provides 1+1 High-Availability (HA) protection. Theapplication executes on one blade. The other blade acts as a hot standby in case the first blade fails toprovide service.

Expanded List

70001 - QP-procmgr failedAlarm Type: QP

Description: The QP-procmgr process has failed.

Severity: Critical

Instance: N/A

HA Score: Failed

Clearing Action: This alarm is cleared by qp-procmgr after qp-procmgr is restarted.

Recovery:

If the alarm does not clear automatically within a few seconds, or if the alarm occurs frequently,contact the Tekelec Customer Care Center.

70002 - QP Critical process failedAlarm Type: QP

Description: The QP-procmgr has detected that one of the critical processes it monitors has failed.

Severity: Critical

Instance: N/A

HA Score: Normal

Clearing Action: This alarm is cleared by qp-procmgr as qp-procmgr shuts down.

Recovery:

If the alarm does not clear automatically within a few seconds, or if the alarm occurs frequently,contact the Tekelec Customer Care Center.

70003 - QP Non-critical process failedAlarm Type: QP

Description: The QP-procmgr has detected that one of the non-critical processes it monitors has failed.

59910-6403-001 Revision A, June 2012

Support for Traps

Page 60: SNMP User's Guide

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

If the alarm occurs infrequently, monitor the health of the system. If the alarm occurs frequently,contact the Tekelec Customer Care Center.

70004 - QP Processes down for maintenanceAlarm Type: QP

Description: The QP processes have been brought down for maintenance.

Severity: Major

Instance: N/A

HA Score: Failed

Clearing Action: This alarm clears when the QP processes are restarted and exit maintenance.

Recovery:

If the alarm is occurring, confirm that the server is down for maintenance.

70009 - QP Topology Configuration MismatchAlarm Type: QP

Description: The QP-procmgr has detected that its Topology configuration (topology or VIP) doesnot match the configuration in the database.

Running cluster configuration:

• Topology={Undefined, Unmated, Mated}• Mate={x.x.x.x}• OAM VIP={x.x.x.x}• SIG-A VIP={x.x.x.x},• SIG-B VIP={x.x.x.x}

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: qp_procmgr exit

Recovery:

Restart the qp_procmgr service either through a full reboot or becoming root and performing‘service qp_procmgr restart’.

60910-6403-001 Revision A, June 2012

Support for Traps

Page 61: SNMP User's Guide

70010 - Failed server-backup remote archive rsyncAlarm Type: QP

Description: A scheduled backup failed to synchronize the local server-backup archive with the remoteserver-backup archive.

• Hostname=<hostname | IPaddr>• user=<user>• path=<path>• errorcode=<rsync error>

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 600 seconds (10 minutes).

Recovery:

Check that the parameters are correct. Take corrective action based on the returned Error CodeDetails for Alarms 70010 and 70011.

Error Code Details for Alarms 70010 and 70011

MeaningError Code

Syntax or usage error1

Protocol incompatibility2

Errors selecting input/output files, dirs3

Requested action not supported: an attempt was made to manipulate 64-bit files on aplatform that cannot support them; or an option was specified that is supported bythe client and not by the server

4

Error starting client-server protocol5

Daemon unable to append to log-file6

Error in socket I/O10

Error in file I/O11

Error in rsync protocol data stream12

Errors with program diagnostics13

Error in IPC code14

Received SIGUSR1 or SIGINT20

Some error returned by waitpid()21

Error allocating core memory buffers22

61910-6403-001 Revision A, June 2012

Support for Traps

Page 62: SNMP User's Guide

MeaningError Code

Partial transfer due to error23

Partial transfer due to vanished source files24

The --max-delete limit stopped deletions 30 Timeout in data send/receive25

No mate found. Blade may be in degraded state101

Called from master with '--fromMaster' option102

Incorrect usage103

Failed in key exchange with remote host104

70011 - Failed System BackupAlarm Type: QP

Description: A scheduled backup failed to synchronize the local system-backup archive with theremote system-backup archive.

Hostname=<hostname | IPaddr>, user=<user>, path=<path>,errorcode=<rsync error>

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 600 seconds.

Recovery:

Check that the parameters are correct. Take corrective action based on the returned Error CodeDetails for Alarms 70010 and 70011.

70012 - Failed to create server-backupAlarm Type: QP

Description: A scheduled backup failed to create the local server-backup file.

Failure-reason=<errorcode>

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 600 seconds.

Recovery:

Take corrective action based on the returned error message.

62910-6403-001 Revision A, June 2012

Support for Traps

Page 63: SNMP User's Guide

70013 - Failed to create system-backupAlarm Type: QP

Description: A scheduled backup failed to create the local system-backup file.

Failure-reason=<errorcode>

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 600 seconds.

Recovery:

Take corrective action based on the returned error message.

70015 - VIP Route Add FailedAlarm Type: QP

Description: VIP route add failed to re-apply during VIP event.

The alarm displays the following information:

• IP-Type• Route-Type• Network• Destination• Gateway-Address• Error Message

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 3600 seconds.

Recovery:

Use server UI (Platcfg Routing Menu) to repair the route manually.

70020 - QP Master database is outdatedAlarm Type: QP

Description: The MYSQL master server has an outdated database.

Severity: Critical

Instance: N/A

HA Score: Degraded

63910-6403-001 Revision A, June 2012

Support for Traps

Page 64: SNMP User's Guide

Clearing Action: This alarm clears when the master server either is made a slave server or if a databaserestore action clears the condition.

Recovery:

1. Once the condition has occurred, the 80003 event will be sent once a minute. Wait until all of theexpected servers are being reported. It is important to wait because the best slave might beundergoing a reboot and its DB Level will not be known until after the reboot completes.

2. Use the information in 80003 to select the new master candidate.3. Except for the current master and the master candidate, put all of the other servers into

forcedStandby.4. If the best slave is in the same cluster (the most common case), simply perform a failover by restarting

the current active blade. If the best slave is in a separate cluster, then a site promotion is necessary.5. Remove the forced standby settings on the other slaves.6. If none of the slaves are good candidates, perform a database restore.

a) Put all of the slave servers into forced standby stateb) Perform a restore on the active server.

The restore will clear the condition.c) Take the slave servers out of the standby state.

70021 - DB Synchronization UnconnectedAlarm Type: QP

Description: The slave server is not connected to the master blade.

Severity: Major

Instance: N/A

HA Score: Failed

Clearing Action: This alarm clears automatically when the slave server connects to the master server.

Recovery:

1. No action required unless the alarm does not clear within a few hours.2. If the problem persists, contact the Tekelec Customer Care Center.

70022 - QP Slave database failed to synchronizeAlarm Type: QP

Description: The MySQL slave server failed to synchronize with the master server.

Severity: Major

Instance: N/A

HA Score: Failed

Clearing Action: This alarm clears when the slave server synchronizes with the master server.

Recovery:

1. No action required unless the alarm does not clear within a few hours.

64910-6403-001 Revision A, June 2012

Support for Traps

Page 65: SNMP User's Guide

2. If the problem persists, contact the Tekelec Customer Care Center.

70023 - Slave database lagging the masterAlarm Type: QP

Description:The MYSQL slave server is connected to the master server but its database has fallenbehind the master database.

Severity: Minor

Instance: N/A

HA Score: Degraded

Clearing Action: This alarm clears automatically when the slave database is synchronized with themaster database.

Recovery:

1. No action required unless the alarm does not clear within a few hours or the condition is repeatedlyset and unset.

2. If either of the problems persists, contact the Tekelec Customer Care Center.

70024 - QP Slave database is prevented from synchronizing with the masterAlarm Type: QP

Description:The MySQL slave database has been prevented from synchronization with the masterdatabase because the master database is outdated.

Severity: Critical

Instance: N/A

HA Score: Degraded

Clearing Action: This alarm clears when the slave database is synchronized with the master database.This alarm is set on the slave server and will only occur when the active server on the primary sitehas set alarm 70020. This alarm clears automatically when the slave database is synchronized withthe master database.

Recovery:

1. Diagnose the CMP master server to clear its 70020 alarm.2. Once alarm 70020 is cleared, the slave server will clear alarm 70024.

70025 - QP Slave database is a different version than the masterAlarm Type: QP

Description:The MySQL slave database has a different schema than the master.

Severity: Critical

Instance: N/A

HA Score: Degraded

65910-6403-001 Revision A, June 2012

Support for Traps

Page 66: SNMP User's Guide

Clearing Action: The slave server clears the alarm when the master DB version is equal to the slaveDB version.

Recovery:

This alarm is set by the CMP Slave Server during a CMP Server Upgrade or Backout, when the CMPMaster Server DB is a different version than the CMP Slave Server DB. The Slave Server clears thealarm when the Master Server and the Slave Server again have the same version.

70026 - QP NetBackup in progressAlarm Type: QP

Description: Server is performing a Symantec NetBackup Operation.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: The slave server clears the alarm when the master DB version is equal to the slaveDB version.

Recovery:

1. This alarm is set by the CMP Slave Server during a CMP Server Upgrade or Backout, when theCMP Master Server DB is a different version than the CMP Slave Server DB. The Slave Server clearsthe alarm when the Master Server and the Slave Server again have the same version.

2. If the alarm does not clear within a few hours, then check the NetBackup Server Logs.3. If the NetBackup Server logs have no errors, or if the alarm is occurring over and over, contact

Tekelec Customer Care Center.

Policy Server Alarms (71000 - 89999)

Expanded List

71004 - AM CONN LOSTAlarm Type: PCRF

Description: AM socket closed.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: AM connection restored to remote peer.

Recovery:

1. Check the availability of the AM.2. Check the AM log for a recent failover or other operations that can interrupt communications.

66910-6403-001 Revision A, June 2012

Support for Traps

Page 67: SNMP User's Guide

3. If the AM has not failed, make sure that the path from the AM to the MPE device (port 3918) isoperational.

4. If the problem persists, contact the Tekelec Customer Care Center.

71101 - DQOS DOWNSTREAM CONNECTION CLOSEDAlarm Type:PCRF

Description: DQoS Downstream connection is closed.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: DQOS connection restored to a remote peer.

Recovery:

Contact the Tekelec Customer Care Center.

71102 - MSC CONN LOSTAlarm Type: PCRF

Description: The connection was lost to the specified CMTS or downstream policy server.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to a remote peer is restored.

Recovery:

1. Check configuration and availability of the network element.2. Check the network element for a reboot or other service interruption.3. If the element has not failed, make sure that the network path from the MPE device to the element

(port 3918) is operational.4. If the problem persists, contact the Tekelec Customer Care Center.

71104 - DQOS AM CONNECTION CLOSEDAlarm Type: PCRF

Description: DQoS AM Connection Closed.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to a remote peer is restored.

Recovery:

67910-6403-001 Revision A, June 2012

Support for Traps

Page 68: SNMP User's Guide

Contact the Tekelec Customer Care Center.

71204 - SPC CONN CLOSEDAlarm Type: PCRF

Description: SPC Socket closed.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to a remote peer is restored.

Recovery:

Contact the Tekelec Customer Care Center.

71402 - TRANSPORT CLOSEDAlarm Type: PCRF

Description: A connection with a Diameter peer has been closed by a network element.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Autoclear

Recovery:

1. Check the configuration and availability of the network element.2. Check the network element for a reboot or other service interruption.3. If the network element has not failed, ensure the network path from the device to the network

element is operational.4. If the problem persists, contact the Tekelec Customer Care Center.

71403 - TRANSPORT DISCONNECTEDAlarm Type: PCRF

Description: Diameter connection socket is closed.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Autoclear

Recovery:

1. Check the configuration and availability of the network element.

68910-6403-001 Revision A, June 2012

Support for Traps

Page 69: SNMP User's Guide

2. Check the network element for a reboot or other service interruption.3. If the network element has not failed, ensure the network path from the device to the network

element is operational.4. If the problem persists, contact the Tekelec Customer Care Center.

71408 - NEW CONN REJECTEDAlarm Type: PCRFDescription: New connection rejected as an already functioning one exists. A Diameter peer (identifiedby its Diameter Identity) attempted to establish a connection with the device although it already hasa valid connection. The Diameter protocol allows only one connection from a particular peer.

Note: This situation only occurs when DIAMETER.AllowMultipleConnectionsPerPeer is set to false,or when the multiple connections setting is turned off on the advanced tab of the policy server tab inthe CMP GUI.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 seconds.

Recovery:

1. Check the peer configuration and ensure that the peer sees a valid connection with the device.2. If the problem persists, contact the Tekelec Customer Care Center.

71414 - SCTP Path Status ChangedAlarm Type: PCRFDescription: Occurs when an MPE or MRA is multihoming. The alarm occurs when one path fails,and clears when the path becomes available again. If the path that is currently transmitting diametermessages fails, the alarm is triggered when the SCTP association tries to send the next diametermessage. If the path is not transmitting diameter messages (it is a backup) then it may take up to 30seconds for the alarm to be triggered, since heartbeat chunks are sent every 30 seconds.

Severity: Minor

Instance: Peer address + Association ID

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 seconds.

Recovery:

If the problem persists, contact the Tekelec Customer Care Center.

71605 - LDAP CONN FAILEDAlarm Type: PCRF

Description: Connection to LDAP server failed.

69910-6403-001 Revision A, June 2012

Support for Traps

Page 70: SNMP User's Guide

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to LDAP server is restored.

Recovery:

Verify that there is no problem with the LDAP server or the network path used to reach the server.If the problem persists, contact the Tekelec Customer Care Center.

71630 - DHCP UNEXPECTED EVENT IDAlarm Type: PCRF

Description: DHCP Communication exception.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Next successful DHCP operation will clear this alarm.

Recovery:

Contact the Tekelec Customer Care Center.

71631 - DHCP UNABLE TO BIND EVENT IDAlarm Type: PCRF

Description: DHCP unable to bind event ID.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Next successful DHCP bind operation will clear this alarm.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71632 - DHCP RESPONSE TIMEOUT EVENT IDAlarm Type: PCRF

Description: DHCP Response Timeout Event Id.

Severity: Minor

Instance: N/A

HA Score: Normal

70910-6403-001 Revision A, June 2012

Support for Traps

Page 71: SNMP User's Guide

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71633 - BAD RELAY ADDRESS EVENT IDAlarm Type: PCRF

Description: DHCP bad relay address event id.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71634 - DHCP BAD PRIMARY ADDRESS EVENT IDAlarm Type: PCRF

Description: No primary address specified.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71635 - DHCP BAD SECONDARY ADDRESS_EVENT IDAlarm Type: PCRF

Description: No secondary address is specified.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 seconds.

Recovery:

71910-6403-001 Revision A, June 2012

Support for Traps

Page 72: SNMP User's Guide

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71684 - SPR CONNECTION CLOSEDAlarm Type: PCRF

Description: SPR Closing a secondary connection to revert to primary connection.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to SPR is restored.

Recovery:

Contact the Tekelec Customer Care Center.

71685 - MSR DB NOT REACHABLEAlarm Type: PCRF

Description: Unable to connect to MSR after several attempts.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to MSR is restored.

Recovery:

Verify that there is no problem with the MSR server or the network path used to reach the server.If the problem persists, contact the Tekelec Customer Care Center.

71702 - BRAS CONNECTION CLOSEDAlarm Type: PCRF

Description: The MPE lost a connection to the B-RAS element of the gateway.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to BRAS is restored.

Recovery:

1. Check availability of the gateway.2. If the gateway has not failed, make sure that the path from the gateway to the MPE is operational.3. If the problem persists, contact the Tekelec Customer Care Center.

72910-6403-001 Revision A, June 2012

Support for Traps

Page 73: SNMP User's Guide

71703 - COPS UNKNOWN GATEWAYAlarm Type: PCRF

Description: An unknown gateway is trying to establish a COPS-PR connection to the MPE.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: COPS network element is associated with MPE.

Recovery:

1. Check the configuration of the network elements in the CMP. There should be a B-RAS networkelement for this gateway and that B-RAS must be associated with this MPE.Make sure that the configuration of the B-RAS network element is consistent with the provisionedinformation on the gateway. The network element name in the CMP must match the provisionedrouter name on the gateway.

2. If the problem persists, contact the Tekelec Customer Care Center.

71801 - PCMM NO PCEFAlarm Type: PCRF

Description: PCMM no PCEF.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

71805 - PCMM NOCONNECTION PCEFAlarm Type: PCRF

Description: PCMM Non Connection to PCEF.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

73910-6403-001 Revision A, June 2012

Support for Traps

Page 74: SNMP User's Guide

72198 - Switched back to primary SMSCAlarm Type: SMS

Description: Switched from Secondary to Primary SMSC.

Severity: Minor

Instance: SMSC address

HA Score: Normal

Clearing Action: Auto clear after 60 minutes

Recovery:

No action necessary.

72199 - Switched to secondary SMSCAlarm Type: SMPP

Description: Switched from Primary to Secondary SMSC.

Severity: Minor

Instance: SMSC Address

HA Score: Normal

Clearing Action: Auto clear after 60 minutes

Recovery:

No action necessary.

72210 - PCMM REACHED MAX GATES EVENT IDAlarm Type: PCRF

Description: PCMM reached maximum gates. A subscriber at IP address ip-addr has reached theconfigured maximum number of upstream gates.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

72211 - PCMM REACHED MAX GPI EVENT IDAlarm Type: PCRF

74910-6403-001 Revision A, June 2012

Support for Traps

Page 75: SNMP User's Guide

Description: PCMM reached maximum GPI. A subscriber at IP address ip-addr has reached theconfigured maximum grants per interval on all upstream gates.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 60 seconds.

Recovery:

1. This subscriber address is exceeding the capacity; attention is required.2. Contact the Tekelec Customer Care Center.

72501 - SCE CONNECTION LOSTAlarm Type: PCRF

Description: SCE Connection is lost.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Connection to SCE is restored.

Recovery:

Contact the Tekelec Customer Care Center.

72549 - SMSR queue fullAlarm Type: SMS

Description: SMSR internal queue has reached capacity. This will result in messages being droppeduntil the queue is free to accept new messages.

Severity: Minor

Instance: SMSR queue

HA Score: Normal

Clearing Action: Auto clear after 60 minutes

Recovery:

Contact the Tekelec Customer Care Center.

72559 - SMSC connection closedAlarm Type: SMPP

Description: SMSC connection closed.

Severity: Minor

75910-6403-001 Revision A, June 2012

Support for Traps

Page 76: SNMP User's Guide

Instance: SMSC address

HA Score: Normal

Clearing Action: Auto clear after 60 minutes

Recovery:

No action necessary.

72565 - SMSR SMTP connection closedAlarm Type: SMTP

Description: SMTP connection has been closed to MTA {IP Address}.

Severity: Minor

Instance: {hostname of MTA}

HA Score: Normal

Clearing Action: Auto clear after 60 minutes

Recovery:

Contact the Tekelec Customer Care Center.

72703 - RADIUS SERVER START FAILEDAlarm Type: PCRF

Description: RADIUS server start failed.

Severity: Minor

Instance: N/A

HA Score: N/A

Clearing Action: TBD

Recovery:

Contact the Tekelec Customer Care Center.

72706 - RADIUS SERVER CORRUPT AUTHAlarm Type: PCRF

Description: Authenticator is corrupted.

Severity: Minor

Instance: N/A

HA Score: N/A

Clearing Action: TBD

Recovery:

76910-6403-001 Revision A, June 2012

Support for Traps

Page 77: SNMP User's Guide

Contact the Tekelec Customer Care Center.

72904 - DIAMETER TOO BUSYAlarm Type: PCRF

Description: Diameter load shedding set a busy status.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: The Diameter load drops below admission criteria thresholds or this alarm clearsautomatically after 30 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

72905 - RADIUS TOO BUSYAlarm Type: PCRF

Description: RADIUS load shedding set a busy status.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: The RADIUS load drops below admission criteria thresholds or this alarm clearsautomatically after 30 seconds.

Recovery:

If this alarm occurs infrequently, then monitor the health of the system. If this alarm occursfrequently, contact the Tekelec Customer Care Center.

74000 - POLICY CRITICAL ALARMAlarm Type: PCRF

Description: Critical Policy alarm.

Severity: Critical

Instance: N/A

HA Score: Normal

Clearing Action: This alarm can be cleared by a policy or clears automatically after 3600 seconds (onehour).

Recovery:

Contact the Tekelec Customer Care Center.

77910-6403-001 Revision A, June 2012

Support for Traps

Page 78: SNMP User's Guide

74001 - POLICY MAJOR ALARMAlarm Type: PCRF

Description: Major Policy alarm.

Severity: Major

Instance: N/A

HA Score: Normal

Clearing Action: This alarm can be cleared by a policy or clears automatically after 3600 seconds (onehour).

Recovery:

Contact the Tekelec Customer Care Center.

74002 - POLICY MINOR ALARMAlarm Type: PCRF

Description: Minor Policy alarm.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm can be cleared by a policy or clears automatically after 3600 seconds (onehour).

Recovery:

Contact the Tekelec Customer Care Center.

74020 - Delete expire filesAlarm Type: CMP

Description: Stats Files Generator Task has removed some files which weren't synced to remote servers(<external system IP>,<external system IP>, etc).

Severity: Major

Instance: Stats files generator

HA Score: Normal

Clearing Action: Auto clear 300 seconds

Recovery:

Check all enabled Stats Files Synchronization tasks status in the DC (Data Collection) tasks of CMP,and ensure they are configured successfully.

78910-6403-001 Revision A, June 2012

Support for Traps

Page 79: SNMP User's Guide

74021 - File synchronization failureAlarm Type: CMPDescription: Stats Files Synchronization #<X> task failed to sync local to remote server (<externalsystem Host Name/IP>) after retry <N> times, where:

• X: task #• N: 1-5 retry times• External system Host Name/IP: user-defined remote server's address to which files are synced

Severity: Minor

Instance: Stats files synchronization

HA Score: Normal

Clearing Action: Auto clear 300 seconds

Recovery:

Check the network status of the remote server which you configured in the Stats FilesSynchronization task; ensure remote server supports SSH protocol and you configured the username and password correctly.

74600 - MPE or MRA rejects a secondary connectionAlarm Type: MPE, MRA

Description: MPE or MRA rejects a secondary connection. Server IP that MPE/MRA is attempting toconnect to is identified. This alarm likely indicates network connectivity issues in your network. Oncethose issues are resolved, this issue should go away.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 minutes.

Recovery:

1. Fix network problems and restore connectivity.2. Place one of the Active servers in the cluster into Forced Standby mode.3. If alarm persists, contact the Tekelec Customer Care Center.

74601 - MPE or MRA reverts from a secondary connection to a primary connectionAlarm Type: MPE, MRA

Description: MPE/MRA reverts from a secondary connection to a primary connection. Both connectionsare identified. This alarm likely indicates network connectivity issues in your network. Once thoseissues are resolved, this issue should go away.

Severity: Minor

Instance: N/A

79910-6403-001 Revision A, June 2012

Support for Traps

Page 80: SNMP User's Guide

HA Score: Normal

Clearing Action: This alarm clears automatically after 30 minutes.

Recovery:

1. Fix network problems and restore connectivity.2. Place one of the Active servers in the cluster into Forced Standby mode.3. If alarm persists, contact the Tekelec Customer Care Center.

74602 - More than one server in a cluster is Active at a timeAlarm Type: MPE, MRA

Description: Multiple Active servers have been detected in the same cluster; the cluster is in SplitBrain state.

Severity: Critical

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears when HA recovers or can clears automatically after 30 minutes.When HA recovers there will be only one Active server in a cluster.

Recovery:

1. Fix network problems and restore connectivity.2. Place one of the Active servers in the cluster into Forced Standby mode.3. Contact the Tekelec Customer Care Center.

74603 - Max primary site failure threshold reachedAlarm Type: MPE

Description: Number of failed MPE pairs reaches the threshold of {Max Primary Site Failure Threshold}at {Site}, where:

• Max Primary Site Failure Threshold is the configured threshold value• Site is the site name

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears when the number of failed MPE pairs remain at a lower value thanthe threshold of {Max Primary Site Failure Threshold} at {Site}, or clears automatically after 30 minutes.

Recovery:

1. When the failure count drops below the threshold value and stays below the threshold for 30seconds, the alarm is cleared. (The 30 seconds delay prevents the alarm from being cleared toosoon.)

2. If alarm doesn't clear automatically, contact the Tekelec Customer Care Center.

80910-6403-001 Revision A, June 2012

Support for Traps

Page 81: SNMP User's Guide

74604 - Policy Cluster Offline FailureAlarm Type: MPE, MRA

Description: Policy Cluster is offline.

Severity: Critical

Instance: N/A

HA Score: Normal

Clearing Action: This alarm clears when a server in the MPE cluster comes online. The alarm clearsautomatically after 30 minutes.

Recovery:

1. When a server comes online ( in Active, Standby, or Spare state), the alarm is cleared. Please checkwhether all servers are powered down or rebooted at that time.

2. If alarm doesn't clear automatically, contact the Tekelec Customer Care Center.

75000 - Policy library loading failedAlarm Type: PCRF

Description: PCRF was unable to load the latest policy library. If this alarm occurred at startup timeor at failover, this indicates the PCRF does not have any policies deployed. If this alarm occurred ona new policy push when PCRF was running with some existing policies, this alarm indicates that thePCRF will continue to run with those existing policies.

Severity: Minor

Instance: N/A

HA Score: Normal

Clearing Action: Performing a reapply config may fix the problem.

Recovery:

1. Perform a reapply config from the CMP to reload the library.2. If the problem persists, contact the Tekelec Customer Care Center.

80001 - DB State TransitionAlarm Type: QP

Description: The MySQL database manager generates a "MySQL state transition" event every timeit makes a state-machine transition. The event text describes the transition.

Severity:

Instance: MySQL

HA Score: N/A

Clearing Action: This alarm is cleared by qp-procmgr as qp-procmgr shuts down.

OID suffix: QPCriticalProcFailed

81910-6403-001 Revision A, June 2012

Support for Traps

Page 82: SNMP User's Guide

Recovery:

No action required.

80002 - MySQL Relay Log DroppedAlarm Type: QP

Description: This event is raised when a slave server times out while trying to apply its relay logduring a slave stop. The server may not be hurt, but there may be aftereffects. This event is raised totrigger a debug for possible aftereffects.

Severity: Debug

Instance: N/A

HA Score: N/A

Clearing Action: N/A

OID suffix: N/A

Recovery:

Debug the system for possible aftereffects caused by the timeout.

80003 - MySQL DB LevelAlarm Type: QP

Description: If the master database is outdated, the server raises this event once per minute. Theserver will rank the slaves, from best to worst, based on their database level .

Severity: Debug

Instance: N/A

HA Score: N/A

Clearing Action:N/A

OID suffix: N/A

Recovery:

Use the information of this event to help resolve an outdated master database raised by alarm70020.

82704 - Binding release taskAlarm Type: MRA

Description: The binding release task has started, completed, or aborted.

Severity: Info

Instance: N/A

HA Score: Normal

82910-6403-001 Revision A, June 2012

Support for Traps

Page 83: SNMP User's Guide

Clearing Action: Autoclears in 300 secs

OID suffix: pcrfMIBNotificationsBindingReleaseTaskNotify

Recovery:

No action required.

84004 - POLICY INFO EVENTAlarm Type: PCRF

Description: Application is ready.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: PolicyInfoEvent

Recovery:

No action required.

86001 - APPLICATION IS READYAlarm Type: PCRF

Description: Application is ready.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: ApplicationIsReady

Recovery:

No action required.

86100 - CPM USER LOGINAlarm Type: PCRF

Description: User [ABC] login succeeded.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

83910-6403-001 Revision A, June 2012

Support for Traps

Page 84: SNMP User's Guide

OID suffix: UserLoginNotify

Recovery:

No action required.

86101 - CPM USER LOGIN FAILEDAlarm Type: PCRF

Description: User [ABC] login failed.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: UserLoginFailedNotify

Recovery:

No action required.

86102 - CPM USER LOGOUTAlarm Type: PCRF

Description: User [ABC] logout.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: UserLogoutNotify

Recovery:

No action required.

86200 - CPM USER PROMOTED SERVERAlarm Type: PCRF

Description: Application is ready.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: ApplicationIsReady

84910-6403-001 Revision A, June 2012

Support for Traps

Page 85: SNMP User's Guide

Recovery:

No action required.

86201 - CPM USER DEMOTED SERVERAlarm Type: PCRF

Description: User [ABC] demoted [1/2] CMP.

Severity: Info

Instance: N/A

HA Score: Normal

Clearing Action: N/A

OID suffix: UserDemotedServerNotify

Recovery:

No action required.

85910-6403-001 Revision A, June 2012

Support for Traps

Page 86: SNMP User's Guide

GlossaryA

application managerAM

A server within a network that isresponsible for establishing andmanaging subscriber sessionsassociated with a specificapplication.

B

broadband remote access serverB-RAS

C

See CMP.Camiant Management Platform

Configuration Management PlatformCMP

A centralized management interfaceto create policies, maintain policylibraries, configure, provision, andmanage multiple distributed MPEpolicy server devices, and deploypolicy rules to MPE devices. TheCMP has a web-based interface.

Cable modem termination systemCMTS

An edge device connecting tosubscribers' cable modems in abroadband network. A CMTS devicecan function as a PCEF device; seePCEF.

D

DatabaseDB

Domain Name SystemDNS

A system for converting Internethost and domain names into IPaddresses.

86910-6403-001 Revision A, June 2012

Page 87: SNMP User's Guide

D

Dynamic Quality of ServiceDQoS

A COPS-based protocol that is partof the Packet Cable standards usedto communicate between a CMS anda CMTS for setting up voice calls. AnMPE device can be inserted betweenthese two entities to apply additionalpolicy rules as sessions areestablished.

G

Graphical User InterfaceGUI

The term given to that set of itemsand facilities which provide theuser with a graphic means formanipulating screen data ratherthan being limited to characterbased commands.

H

High AvailabilityHA

High Availability refers to a systemor component that operates on acontinuous basis by utilizingredundant connectivity, therebycircumventing unplanned outages.

Hewlett-PackardHP

M

Multimedia Policy EngineMPE

A high-performance,high-availability platform foroperators to deliver and managedifferentiated services overhigh-speed data networks. The MPEincludes a protocol-independentpolicy rules engine that providesauthorization for services based onpolicy conditions such as subscriberinformation, application

87910-6403-001 Revision A, June 2012

Glossary

Page 88: SNMP User's Guide

M

information, time of day, and edgeresource utilization.

Multi-Protocol Routing AgentMRA

Scales the Policy Managementinfrastructure by distributing thePCRF load across multiple PolicyServer devices.

Major Trading AreaMTA

See MPE.Multimedia Policy Engine

See MRA.Multiprotocol Routing Agent

N

Network Time ProtocolNTP

P

Policy and Charging EnforcementFunction

PCEF

Policy and Charging Rules FunctionPCRF

The ability to dynamically controlaccess, services, network capacity,and charges in a network.

Platform Management andConfiguration

PM&C

Server with hardware managementsoftware that manages theremaining servers (System OAMsand MPs) in a network element.The terms PM&C and systemmanager are used synonymouslyin the online help documentation.PM&C functions include hardwaremonitoring and control, switch

88910-6403-001 Revision A, June 2012

Glossary

Page 89: SNMP User's Guide

P

configuration, and softwareinstallation and upgrade.

Provides hardware and platformmanagement capabilities at the sitelevel for Tekelec platforms. ThePMAC application manages andmonitors the platform and installsthe TPD operating system from asingle interface.

Q

See QP.QBus Platform

QBus PlatformQP

Software that provides an executionenvironment for Java-basedapplications, providing commoninterfaces into databases, eventlogging, SNMP, and cluster state.

S

SMS Relay ApplicationSMSR

An interface between the MPE andSMSC or other specific SMS webservice(s).

Simple Network ManagementProtocol.

SNMP

An industry-wide standard protocolused for network management. TheSNMP agent maintains datavariables that represent aspects ofthe network. These variables arecalled managed objects and arestored in a management informationbase (MIB). The SNMP protocolarranges managed objects intogroups.

Simple Object Access ProtocolSOAP

89910-6403-001 Revision A, June 2012

Glossary