snmp reference 2 · 2020-02-27 · getting started with snmp nimble storage software provides an...
TRANSCRIPT
SNMP Reference
Version 2.3
Legal Notices
Copyright 2010-2015 Nimble Storage, Inc. All rights reserved worldwide.
No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or byelectronic, mechanical, recording, photocopy, scanning or other means without prior written permission fromNimble Storage, Inc.
The product described in this documentation may be protected by US Patent 8,285,918, US Patent 8,832,330and other pending patent applications.
Nimble Storage, Incorporated (Nimble), has used the latest information that is available in producing thisdocument. Nimble Storage makes no warranty, expressed or implied, with regard to accuracy andcompleteness.
Information in this document is subject to change without notice.
Nimble Storage, the Nimble Storage logo, CASL, InfoSight, SmartStack and NimbleConnect are trademarksor registered trademarks of Nimble Storage. All brand names and product names mentioned in this documentare trademarks of their respective owners. Where known, trademarked, registered trademarks, and servicemarks are designated as such.
InfoSight® is a registered trademark in Japan of Intage Inc. of Japan. Usage of InfoSight® in Japan is permittedpursuant to a trademark license agreement between Nimble Storage, Inc. and Intage Inc.
Nimble Storage, Inc.211 River Oaks ParkwaySan Jose, CA 95134U.S.A.
Tel: +1 408.432.9600Website: http://www.nimblestorage.comSales: [email protected]
SupportAll documentation and knowledge base articles are available on the Nimble Storage Support site athttps://infosight.nimblestorage.com. To register on InfoSight, click the Enroll Now link on the main page.
Email: [email protected].
For all other general support contact information, go to http://www.nimblestorage.com/support.
Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Contents
Getting Started with SNMP..........................................................................4Set up SNMP.......................................................................................................................................5
IANA and OID Numbers.......................................................................................................................7
Nimble MIB Variables...................................................................................9Nimble MIB Variables Overview.........................................................................................................10
Volume-Specific MIB Variables..........................................................................................................10
Global MIB Variables..........................................................................................................................14
SNMP Traps................................................................................................16Traps and Trap Variables....................................................................................................................17
Events and Alert Messages...............................................................................................................18
Nimble SNMP FAQ..........................................................................................................72
Regulatory Information..................................................................................................73Regulatory Warnings.........................................................................................................................73
Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Getting Started with SNMP
Nimble Storage software provides an SNMP option for monitoring Nimblecontroller shelves. You should be familiar with the Simple Network
Topics:
• Set up SNMP Management Protocol (SNMP) before you enable SNMP monitoring.• IANA and OID Numbers You can use RFC1155 to familiarize yourself with SNMP-related concepts
and Management Information Base-related (MIB) concepts.
On each array, an SNMP agent provides information about the networkconfiguration and operations. These SNMP objects are stored in a MIB.The MIB is a virtual database by the IETF/IEEE as well as deviceproviders like Nimble Storage to ensure a standard method to viewnetwork management information on devices from different vendors.
Nimble Storage provides a MIB specific to its storage arrays. You candownload the Nimble MIB from the Nimble Storage Support site.
4Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Getting Started with SNMP
Set up SNMPThe Nimble array uses SNMP to communicate with network management systems.It supports SNMP versions 1, 2, and 2c. However, the device sends traps but does not receive them. Youcan download the Nimble SNMP MIB from the Nimble Storage Support site.
Note The array uses the alert level settings for email alerts to determine the events that are sent as SNMPtraps.
SNMP sends information to the network in one of two ways. Using the first method, shown as 1 in the diagram,the network management system sends a request to retrieve information and then subsequently receives aresponse. Using the second method, shown as 2, the traps are sent automatically, based on trap level settings.
5Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Set up SNMP
To configure SNMP traps using the CLI:
1 Type the following command to enable SNMP traps: --snmp_trap_host
2 Type the following command to configure the SNMP trap destination:array --snmp_trap_dest
To configure SNMP traps using the GUI:
3 From the main menu, select Administration > Alerts & Monitoring > SNMP.
4 In the SNMP Get panel:
a) Check Enable SNMP Get.b) Type a new password in the community string field if you want to use a password other than the
default password, which is public.
The community string represents a password that is shared between the client and server (networkmanagement system). It can be represented with up to 64 alphanumeric characters, and can containa hyphen, colon, or period. However, only alphanumerics are allowed to begin the string.
Note Contact Nimble Storage Support before you modify the password.
c) Type the port number in the SNMP Port field if you want to use a port number other than the defaultport number, which is 161.
d) Type the administrative contact email address for the array in the System Contact field.e) Type the physical location of the array in the System Location field.
5 In the SNMP TRAP panel:
a) Click Enable SNMP Trap.b) Type a host name or fully qualified domain name in the Trap Destination field.
The trap destination represents the hostname of the network management system to which SNMPtraps are sent.
c) Type the port number in the Trap Destination Port field if you want to use a port number other thanthe default port number, which is 162.
6 Click Save.
6Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
IANA and OID Numbers
IANA and OID NumbersThe Internet Assigned Numbers Authority (IANA) number assigned to Nimble Storage is 37447: everythingin the Nimble MIB is under the OID
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).nimble(37447)
Wherever you see references to variable names, you can find the corresponding OID numbers in the followingsection. For details about IANA, visit www.iana.org.
About OIDs
The following shows the OID numbers for the variables, tables, and traps in the MIB. The indentations showthe level for each item.
Indexed table entries in SNMP, such as those in the volTable, are accessed by appending the index numberafter the OID of the entry desired.
For example, if a system has 15 volumes (indicated by the variable volNumberOfVolumes value of 15),the name of the 8th volume is obtained by polling (performing an SNMP GET operation) on the OID1.3.6.1.4.1.37447.1.2.1.3.8.
(1) iso(3) org
(6) dod(1) internet
(4) private(1) enterprises
(37447) nimble(1) nimbleVariables
(1) volNumberOfVolumes(2) volTable
(1) volEntry(1) volIndex(2) volID(3) volName(4) volSizeLow(5) volSizeHigh(6) volUsageLow(7) volUsageHigh(8) volReserveLow(9) volReserveHigh(10) volOnline(11) volNumConnections(12) volStatTimeEpochSeconds(13) volIoReads(14) volIoReadTimeMicrosec(15) volIoReadBytes(16) volIoSeqReads(17) volIoSeqReadBytes(18) volIoNonseqReadTotalHits(19) volIoNonseqReadMemHits(20) volIoNonseqReadSSDHits(21) volIoReadLatency0uTo100u(22) volIoReadLatency100uTo200u(23) volIoReadLatency200uTo500u(24) volIoReadLatency500uTo1m(25) volIoReadLatency1mTo2m(26) volIoReadLatency2mTo5m(27) volIoReadLatency5mTo10m
7Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Getting Started with SNMP
(28) volIoReadLatency10mTo20m(29) volIoReadLatency20mTo50m(30) volIoReadLatency50mTo100m(31) volIoReadLatency100mTo200m(32) volIoReadLatency200mTo500m(33) volIoReadLatency500mTomax(34) volIoWrites(35) volIoWriteTimeMicrosec(36) volIoWriteBytes(37) volIoSeqWrites(38) volIoSeqWriteBytes(39) volIoWriteLatency0uTo100u(40) volIoWriteLatency100uTo200u(41) volIoWriteLatency200uTo500u(42) volIoWriteLatency500uTo1m(43) volIoWriteLatency1mTo2m(44) volIoWriteLatency2mTo5m(45) volIoWriteLatency5mTo10m(46) volIoWriteLatency10mTo20m(47) volIoWriteLatency20mTo50m(48) volIoWriteLatency50mTo100m(49) volIoWriteLatency100mTo200m(50) volIoWriteLatency200mTo500m(51) volIoWriteLatency500mTomax(52) volDiskVolBytesUsedLow(53) volDiskVolBytesUsedHigh(54) volDiskSnapBytesUsedLow(55) volDiskSnapBytesUsedHigh
(3) nimbleGlobalStats(1) statTimeEpochSeconds(2) ioReads(3) ioSeqReads(4) ioWrites(5) ioSeqWrites(6) ioReadTimeMicrosec(7) ioWriteTimeMicrosec(8) ioReadBytes(9) ioSeqReadBytes(10) ioWriteBytes(11) ioSeqWriteBytes(12) diskVolBytesUsedLow(13) diskVolBytesUsedHigh(14) diskSnapBytesUsedLow(15) diskSnapBytesUsedHigh(16) ioNonseqReadHits
8Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Getting Started with SNMP
Nimble MIB Variables
The following variables are provided with the Nimble MIB.Topics:
• Nimble MIB Variables Overview• Volume-Specific MIB Variables• Global MIB Variables
9Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables
Nimble MIB Variables OverviewThe Nimble MIB includes volume-specific variables that provide information about all volumes or per-volumeinformation, and global variables that provide other information about the array, such as read I/Os, write I/Os,bytes used on disk, and cache hits. The MIB variables are not updated realtime, but are updated at periodicintervals. The statTimeEpochSeconds variable indicates the UNIX timestamp (in number of seconds sinceUNIX epoch) at which the current reading was taken.
To determine a delta value between two time periods, take one reading and note the timestamp and valuedesired. Then, take a later reading. If the statistics have been updated in the interim, the timestamp for thesecond reading will be higher, and the delta can be computed between the number of seconds in betweenreadings and the difference in the statistic values.
When network management protocols use names of MIB variables in messages, each name has an appendedsuffix. This suffix is called an instance identifier. For simple variables, the instance identifier 0 refers to theinstance of the variable with that name. A MIB can also include tables of related variables.
Typically, an instance identifier might be a unique interface number or a 0. An instance identifier can also bean IP address. For example, to find the network mask for the route with a destination address of131.104.211.243, use the variable locRtMask (locate route mask) with an instance identifier of 131.104.211.243.The format is locRtMask. 131.104.211.243.
Volume-Specific MIB Variables
DescriptionIndexed (part of table)TypeName
Number of volumes.NoUnsigned32volNumberOfVolumes
Volume index.YesUnsigned32volIndex
Volume ID.YesUnsigned32volID
Volume name.YesDisplayStringvolName
Max. size in bytes (loworder bytes).
YesUnsigned32volSizeLow
Max. size in bytes (highorder bytes).
YesUnsigned32volSizeHigh
Usage in bytes (low orderbytes).
YesUnsigned32volUsageLow
Usage in bytes (high or-der bytes).
YesUnsigned32volUsageHigh
Reserved bytes (low orderbytes).
YesUnsigned32volReserveLow
Reserved bytes (high or-der bytes).
YesUnsigned32volReserveHigh
Volume online (true orfalse).
YesTruthValuevolOnline
Number of connections tothe volume.
YesUnsigned32volNumConnections
10Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables Overview
DescriptionIndexed (part of table)TypeName
Time at which the samplewas taken, measured inseconds since UNIXepoch.
YesCounter64volStatTimeEpoch-Seconds
Total cumulative numberof Read I/Os (sequentialand random).
YesCounter64volIoReads
Average time for anyRead operation (sequen-tial and random).
YesCounter64volIoReadTimeMicrosec
Total cumulative numberof Read I/O bytes (sequen-tial and random).
YesCounter64volIoReadBytes
Total Number of Sequen-tial Read I/O operations.
YesCounter64volIoSeqReads
Total cumulative numberof Sequential Read I/Obytes.
YesCounter64volIoSeqReadBytes
Total number of Non-sequential Read I/O hits(to Memory and SSD).
YesCounter64volIoNonseqReadTotal-Hits
Total number of Non-sequential Read I/O hitsto Memory.
YesCounter64volIoNonseqReadMem-Hits
Total number of Non-sequential Read I/O hitsto SSD.
YesCounter64volIoNon-seqReadSSDHits
Number of Read I/O oper-ations with latencybetween 0 and 100 micro-seconds.
YesCounter64volIoRead-Latency0uTo100u
Number of Read I/O oper-ations with latencybetween 100 and 200 mi-croseconds.
YesCounter64volIoRead-Latency100uTo200u
Number of Read I/O oper-ations with latencybetween 200 and 500 mi-croseconds.
YesCounter64volIoRead-Latency200uTo500u
Number of Read I/O oper-ations with latencybetween 1/2 and 1 milli-seconds.
YesCounter64volIoRead-Latency500uTo1m
Number of Read I/O oper-ations with latencybetween 1 and 2 milli-seconds.
YesCounter64volIoRead-Latency1mTo2m
11Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables
DescriptionIndexed (part of table)TypeName
Number of Read I/O oper-ations with latencybetween 2 and 5 milli-seconds.
YesCounter64volIoRead-Latency2mTo5m
Number of Read I/O oper-ations with latencybetween 5 and 10 milli-seconds.
YesCounter64volIoRead-Latency5mTo10m
Number of Read I/O oper-ations with latencybetween 10 and 20 milli-seconds.
YesCounter64volIoRead-Latency10mTo20m
Number of Read I/O oper-ations with latencybetween 20 and 50 milli-seconds.
YesCounter64volIoRead-Latency20mTo50m
Number of Read I/O oper-ations with latencybetween 50 and 100 milli-seconds.
YesCounter64volIoRead-Latency50mTo100m
Number of Read I/O oper-ations with latencybetween 100 and 200milliseconds.
YesCounter64volIoRead-Latency100mTo200m
Number of Read I/O oper-ations with latencybetween 200 and 500milliseconds.
YesCounter64volIoRead-Latency200mTo500m
Number of Read I/O oper-ations with latency above500 milliseconds.
YesCounter64volIoReadLatency500mTo-max
Total cumulative numberof Write I/Os.
YesCounter64volIoWrites
Average time for anyWrite operation (sequen-tial and random).
YesCounter64volIoWriteTimeMicrosec
Total cumulative numberof Write I/O bytes (sequen-tial and random).
YesCounter64volIoWriteBytes
Total Number of Sequen-tial Write I/O operations.
YesCounter64volIoSeqWrites
Number of SequentialWrite I/O bytes.
YesCounter64volIoSeqWriteBytes
Number of Write I/O oper-ations with latencybetween 0 and 100 micro-seconds.
YesCounter64volIoWriteLatency0uTo100u
12Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables
DescriptionIndexed (part of table)TypeName
Number of Write I/O oper-ations with latencybetween 100 and 200 mi-croseconds.
YesCounter64volIoWriteLatency100uTo200u
Number of Write I/O oper-ations with latencybetween 200 and 500 mi-croseconds.
YesCounter64volIoWriteLatency200uTo500u
Number of Write I/O oper-ations with latencybetween 1/2 and 1 milli-seconds.
YesCounter64volIoWriteLatency500uTo1m
Number of Write I/O oper-ations with latencybetween 1 and 2 milli-seconds.
YesCounter64volIoWriteLatency1mTo2m
Number of Write I/O oper-ations with latencybetween 2 and 5 milli-seconds.
YesCounter64volIoWriteLatency2mTo5m
Number of Write I/O oper-ations with latencybetween 5 and 10 milli-seconds.
YesCounter64volIoWriteLatency5mTo10m
Number of Write I/O oper-ations with latencybetween 10 and 20 milli-seconds.
YesCounter64volIoWriteLatency10mTo20m
Number of Write I/O oper-ations with latencybetween 20 and 50 milli-seconds.
YesCounter64volIoWriteLatency20mTo50m
Number of Write I/O oper-ations with latencybetween 50 and 100 milli-seconds.
YesCounter64volIoWriteLatency50mTo100m
Number of Write I/O oper-ations with latencybetween 100 and 200milliseconds.
YesCounter64volIoWriteLatency100mTo200m
Number of Write I/O oper-ations with latencybetween 200 and 500milliseconds.
YesCounter64volIoWriteLatency200mTo500m
Number of Write I/O oper-ations with latency above500 milliseconds.
YesCounter64volIoWriteLatency500mTo-max
13Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables
DescriptionIndexed (part of table)TypeName
Total number of bytesused on disk for volumes- low order bytes.
YesUnsigned32volDiskVolBytesUsedLow
Total number of bytesused on disk for volumes- high order bytes.
YesUnsigned32volDiskVolBytesUsedHigh
Total number of bytesused on disk for snap-shots - low order bytes.
YesUnsigned32volDiskSnapBytesUsed-Low
Total number of bytesused on disk for snap-shots - high order bytes.
YesUnsigned32volDiskSnapBytesUsed-High
Global MIB Variables
DescriptionIndexed (part of table)TypeName
UNIX time (number of secondssince the UNIX epoch) when statswere recorded.
NoCounter64statTimeEpochSeconds
Total cumulative number of ReadI/Os (sequential and random).
NoCounter64ioReads
Total cumulative number of Se-quential Read I/Os.
NoCounter64ioSeqReads
Total cumulative number of WriteI/Os (sequential and random).
NoCounter64ioWrites
Total cumulative number of Se-quential Write I/Os.
NoCounter64ioSeqWrites
Total cumulative microsecondsthe system has spent processingRead I/Os.
NoCounter64ioReadTimeMicrosec
Total cumulative microsecondsthe system has spent processingWrite I/Os.
NoCounter64ioWriteTimeMicrosec
Total cumulative number of ReadI/O bytes (sequential and random).
NoCounter64ioReadBytes
Total cumulative number of Se-quential Read I/O bytes.
NoCounter64ioSeqReadBytes
Total cumulative number of WriteI/O bytes (sequential and random).
NoCounter64ioWriteBytes
Total cumulative number of Se-quential Write I/O bytes.
NoCounter64ioSeqWriteBytes
Total number of bytes used ondisk for volumes (low order bytes).
NoUnsigned32diskVolBytesUsedLow
14Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Global MIB Variables
DescriptionIndexed (part of table)TypeName
Total number of bytes used ondisk for volumes (high orderbytes).
NoUnsigned32diskVolBytesUsedHigh
Total number of bytes used ondisk for snapshots (low orderbytes).
NoUnsigned32diskSnapBytesUsedLow
Total number of bytes used ondisk for snapshots (high orderbytes).
NoUnsigned32diskSnapBytesUsedHigh
Total cumulative number of cachehits for Non-Sequential Read I/Os.
NoCounter64ioNonseqReadHits
15Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble MIB Variables
SNMP Traps
All alert messages that provide information about SNMP traps are usuallysent to administrators using email.
Topics:
• Traps and Trap Variables• Events and Alert Messages
16Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Traps and Trap Variables
About SNMP Trap Variables
The two variables that follow are included (bound) with traps/notifications.
Table 1: SNMP Trap Variables
DescriptionIndexed (part of table)TypeName
Message numberNoUnsigned32nimbleTrapCode
Message stringNoUnsigned32nimbleTrapMsg
About SNMP Traps
Although commonly referred to as traps, these are SNMP v2 notifications. Traps are sent along with eventnotifications and email alerts if they have been configured. The following trap categories represent variousevent notification categories. The specific information of each trap is included in variable bindings that arerepresented by the nimbleTrapCode and nimbleTrapMsg variables.
Table 2: SNMP Trap Categories
DescriptionName
Traps related to general data services.nimbleDataServiceTrap
Traps related to controller operation and status.nimbleControllerTrap
Traps related to miscellaneous services.nimbleServiceTrap
Traps related to the sending of test alerts and traps.nimbleTestTrap
Traps related to software updates.nimbleSoftwareUpdateTrap
Traps related to interaction with the data service.nimbleDataServiceInteractionTrap
Traps related to volumes and snapshots.nimbleVolAndSnapshotTrap
Traps related to volume collections.nimbleVolumeCollectionTrap
Traps related to system space utilization.nimbleSystemSpaceTrap
Traps related to replication.nimbleReplicationTrap
Traps related to general hardware.nimbleHardwareTrap
Traps related to disks.nimbleDiskTrap
Traps related to NICs.nimbleNicTrap
Traps related to environmental components (sensors,temperature, NVRAM batteries, fans, power supplies).
nimbleEnvironmentalTrap
Traps related to RAID.nimbleRaidTrap
Traps related to iSCSI connections.nimbleConnectionTrap
Traps related to system resource limits.nimbleResourceLimitTrap
17Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Traps and Trap Variables
Events and Alert Messages
Table 3: Alert Configuration
Configuration
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Configuration synchronization to arraydelayed
will continue to retry
GroupWarning10244
Configuration synchronization completedfor array
Configuration synchronization completedon array <string>
GroupInformation10245
Group Leader Platform Configuration syn-chronization is delayed
will continue to retry
ControllerWarning10246
Group Leader Configuration synchroniza-tion completed
Group Leader Configuration synchroniza-tion completed on active controller <string>
ControllerInformation10247
Configuration synchronization to arraydelayed
will continue to retry
ControllerWarning10248
Configuration synchronization completedfor array
Configuration synchronization completedon array <string>
ControllerInformation10249
Encryption deactivated
Encryption deactivated. Encryptedvolumes cannot be accessed or created.Enter encryption passphrase to reactivate.
GroupCritical10267
Encryption master key was deleted
Encryption master key was deleted. Nodata was lost because no encryptedvolumes exist.
GroupInformation10268
Encryption mode was changed to securemode
Encryption mode was changed to securemode. An array reboot will require pass-phrase entry.
GroupWarning10269
18Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Events and Alert Messages
Configuration
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Encryption mode was changed to availablemode
Encryption mode was changed to availablemode. An array reboot will not requirepassphrase entry.
GroupWarning10270
Encryption master key was created
Encryption master key was created. En-crypted volumes can now be created.
GroupInformation10271
Encryption passphrase was changed
Encryption passphrase was changed.
GroupInformation10272
Encryption cipher was changed
Encryption default cipher was changed to<string>.
GroupInformation10273
Encryption scope was changed
Encryption default scope was changed to<string>.
GroupInformation10274
Encryption activated
Encryption activated. Encrypted volumescan now be accessed and created.
GroupInformation10275
Encrypted volume access may be slow
Array <string> is a <string> model. Encryp-tion on this array may be slow.
GroupWarning10276
Encryption master key was deleted
Encryption master key was deleted. En-crypted volumes are now permanently in-accessible.
GroupCritical10277
Initiator group synchronization is delayedto arrays in the group
Initiator group <string> synchronization isdelayed to arrays in the group. Synchron-ization will be retried. Additional edits toinitiator groups and creation of new accesscontrol records will fail during the delay.When synchronization succeeds
Initiator GroupWarning10280
Initiator group synchronization to arrays inthe group succeeded
Initiator group <string> synchronization toarrays in the group succeeded.
Initiator GroupInformation10281
19Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Configuration
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Object count reached maximum limit
Number of <string> in <string> hasreached the maximum limit of <decimal>
GroupWarning10500
Object count under maximum limit
Number of <string> in <string> is now un-der the maximum limit of <decimal>
GroupInformation10501
Object count over warning limit
Number of <string> in <string> hasreached the warning limit of <decimal>
GroupWarning10502
Object count under warning limit
Number of <string> in <string> is now un-der the warning limit of <decimal>
GroupInformation10503
Object count reached maximum limit.
Number of <string> <string> in <string>has reached the maximum limit of <string>.
GroupWarning10504
Object count under maximum limit.
Number of <string> <string> in <string> isnow under the maximum limit of <string>.
GroupInformation10505
Object count over warning threshold.
Number of <string> <string> in <string>has reached the warning threshold of<string>.
GroupWarning10506
Object count under warning threshold.
Number of <string> <string> in <string> isnow under the warning threshold limit of<string>.
GroupInformation10507
Table 4: Alert Hardware
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Overtemperature shutdown
Overtemperature on controller <string>
TemperatureCritical12000
Controller overtemperature
Overtemperature on controller <string>(<decimal> Celsius)
TemperatureCritical12001
20Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Backplane over-temperature
Overtemperature on backplane (<decimal>Celsius)
TemperatureCritical12002
Disk failed
Disk <string> failed at slot <decimal>
DiskCritical12100
Disk failed
Disk <string> failed at slot <decimal>
DiskWarning12101
Disk missing
Disk <string> missing at slot <decimal>
DiskWarning12102
Disk added
Disk <string> added at slot <decimal>
DiskInformation12103
Disk removed
Disk <string> at slot <decimal> is removedby user using cli
DiskInformation12104
SSD failed
SSD <string> failed at slot <decimal>
DiskWarning12105
SSD missing
SSD <string> missing at slot <decimal>
DiskWarning12106
SSD added
SSD <string> added at slot <decimal>
DiskInformation12107
SSD removed
SSD <string> at slot <decimal> is removedby user using cli
DiskInformation12108
Foreign disk detected
Disk <string> is not being used
DiskWarning12109
Foreign SSD detected
SSD <string> is not being used
DiskWarning12110
Invalid disk size for this model
Disk <string> of size <decimal> GB is notthe right size for this model
DiskWarning12111
Disk failed
Disk <string> failed on <string> shelf<string> at slot <decimal>
DiskWarning12112
21Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Disk missing
Disk <string> missing
DiskWarning12113
Disk added
Disk <string> added on <string> shelf<string> at slot <decimal>
DiskInformation12114
Disk removed
Disk <string> on <string> shelf <string> atslot <decimal> is removed by user usingcli
DiskInformation12115
SSD failed
SSD <string> failed on <string> shelf<string> at slot <decimal>
DiskWarning12116
SSD missing
SSD <string> missing
DiskWarning12117
SSD added
SSD <string> added on <string> shelf<string> at slot <decimal>
DiskInformation12118
SSD removed
SSD <string> on <string> shelf <string> atslot <decimal> is removed by user-issuedCLI command
DiskInformation12119
Only one SSD drive left
Only a single SSD drive is left in the sys-tem
DiskCritical12120
Disk failed
Disk <string> of capacity <decimal>TBfailed on <string> shelf <string> at slot<decimal>.
DiskWarning12121
Disk added
Disk <string> of capacity <decimal>TBadded on <string> shelf <string> at slot<decimal>.
DiskInformation12122
Disk removed
Disk <string> of capacity <decimal>TB on<string> shelf <string> at slot <decimal>was removed by user-issued CLI com-mand.
DiskInformation12123
22Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
SSD failed
SSD <string> of capacity <decimal>GBfailed on <string> shelf <string> at slot<decimal>.
DiskWarning12124
SSD added
SSD <string> of capacity <decimal>GBadded on <string> shelf <string> at slot<decimal>.
DiskInformation12125
SSD removed
SSD <string> of capacity <decimal>GB on<string> shelf <string> at slot <decimal>was removed by user-issued CLI com-mand.
DiskInformation12126
Invalid disk size for this shelf
Disk <string> of size <decimal> GB is thewrong size on <string> shelf <string> atslot <decimal>. This shelf needs a<decimal> GB disk.
DiskWarning12127
Invalid SSD size for this shelf
SSD <string> of size <decimal> GB is thewrong size on <string> shelf <string> atslot <decimal>. Replace SSD with suppor-ted model or contact Nimble StorageSupport.
DiskWarning12128
Disk not supported on All Flash Shelf
Disk <string> of size <decimal> TB is notsupported on All Flash Shelf <string> atslot <decimal>.
DiskWarning12129
Disk not supported on All-Flash Shelf
Disk <string> of size <decimal> TB is notsupported on All-Flash Shelf <string> atslot <decimal>.
DiskWarning12130
No SSDs found
No SSDs found. This can cause perform-ance degradation and possibly serviceoutages. Insert functioning SSDs in thearray and verify that the array recognizesthe drives.
DiskCritical12131
IP interface down
IP interface <string> down on controller<string> NIC port <string>
NICWarning12200
23Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
IP interface up
IP interface <string> up on controller<string> NIC port <string>
NICInformation12201
Group IP interface unavailable
Group IP interface unavailable
NICWarning12202
All Data IP interfaces unavailable
All Data IP interfaces unavailable
NICWarning12203
IP connectivity lost
all links are down
NICCritical12204
Migrating subnet NIC configuration
NIC <string> for subnet <string> does notexist. Migrating configuration to NIC<string>. Edit configuration if necessary.
NICWarning12205
NIC for subnet missing
NIC <string> for subnet <string> does notexist. Edit configuration to ensure subnetis configured for an existing NIC.
NICWarning12206
Migrating IP NIC configuration
NIC <string> for IP <string> does not exist.Migrating configuration to NIC <string>.Edit configuration if necessary.
NICWarning12207
NIC for IP missing
NIC <string> for IP <string> does not exist.Edit configuration to ensure IP is con-figured for an existing NIC.
NICWarning12208
Migrating route NIC configuration
NIC <string> for route <string> gateway<string> does not exist. Migrating configur-ation to NIC <string>. Edit configuration ifnecessary.
NICWarning12209
NIC for route missing
NIC <string> for route <string> gateway<string> does not exist. Edit configurationto ensure route is configured for an exist-ing NIC.
NICWarning12210
24Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Standby controller has better networkconnectivity. Failing services over tostandby controller
Standby controller has better networkconnectivity. Failing services over tostandby controller
NICInformation12211
Duplicate IP Address Detected
A duplicate of IP address <string> is foundin the network.
NICWarning12212
Discovery IP interface unavailable
Discovery IP interface unavailable
NICWarning12213
Target IP interfaces unavailable
Target IP interfaces unavailable
NICWarning12214
Link down for Group IP interface(s)
Link down for Group IP interface(s)
NICWarning12215
Link down for Discovery IP interface(s)
Link down for Discovery IP interface(s)
NICWarning12216
Link down for Target IP interface(s)
Link down for Target IP interface(s)
NICWarning12217
Link down for Data IP interface(s)
Link down for Data IP interface(s)
NICWarning12218
Link down for iSCSI Data IP interface(s)
Link down for iSCSI Data IP interface(s)
NICWarning12219
Link down for cluster Data IP interface(s)
Link down for cluster Data IP interface(s)
NICWarning12220
Unresponsive NIC Port Detected
NIC Port <string> is unresponsive.
NICWarning12221
IP connectivity lost
all links down on a subnet
NICCritical12222
Network connectivity lost
all links down on a subnet
NICCritical12223
25Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
NIC migration failed
Migration of NIC port(s) <string> failed.This could likely happen if array hardwareupdates resulted in reduced number ofNICs.
NICWarning12224
Sensor: Alert raised
<string> : Min <decimal> Max <decimal>(over <decimal> hours <decimal> mins)Last Reading <decimal>
TemperatureWarning12301
Sensor: Alert cleared
<string> : Min <decimal> Max <decimal>(over <decimal> hours <decimal> mins)Last Reading <decimal>
TemperatureInformation12302
Sensor: Alert raised
<string> : failure
TemperatureWarning12303
Sensor: Alert cleared
<string> : failure cleared
TemperatureInformation12304
Sensor: is missing?:
<string>
TemperatureWarning12305
NVRAM battery is disabled
NVRAM Battery <decimal> is disabled oncontroller <string>
NVRAMWarning12306
NVRAM batteries are disabled
NVRAM <decimal> batteries are disabledon controller <string>
NVRAMCritical12307
NVRAM battery is OK
NVRAM Battery <decimal> is OK on con-troller <string>
NVRAMInformation12308
System temperature is warm
current temperature for sensor at <string>is <decimal> C
TemperatureWarning12310
System temperature is cold
current temperature for sensor at <string>is <decimal> C
TemperatureWarning12311
26Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
System temperature is ok
System temperature is now within range:current temperature for sensor at <string>is <decimal> C
TemperatureInformation12312
Temperature sensor failed
Temperature sensor at <string> is not op-erational
TemperatureWarning12313
Temperature sensor is ok
Temperature sensor at <string> is opera-tional: current temperature is <decimal>C
TemperatureInformation12314
Fan in high speed
Fan at <string> <string> is running fast:current speed <decimal> rpm
Cooling FanInformation12315
Fan in low speed
Fan at <string> <string> is running slow:current speed <decimal> rpm
Cooling FanInformation12316
Fan is ok
Fan at <string> <string> is now running atspeed <decimal> rpm
Cooling FanInformation12317
Fan stopped
Fan at <string> <string> stopped working
Cooling FanWarning12318
Fan missing
Fan at <string> <string> is missing
Cooling FanWarning12319
Power supply fail
Power supply at <string> is either notconnected or failed
Power SupplyWarning12320
Power supply missing
Power supply at <string> is missing
Power SupplyWarning12321
Power supply is ok
Power supply at <string> is ok
Power SupplyInformation12322
System temperature is warm
current temperature for sensor \<string>\at <string> is <decimal> C
TemperatureWarning12323
27Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
System temperature is cold
current temperature for sensor \<string>\at <string> is <decimal> C
TemperatureWarning12324
System temperature is ok
System temperature is now within range:current temperature for sensor \<string>\at <string> is <decimal> C
TemperatureInformation12325
Temperature sensor failed
Temperature sensor \<string>\ at <string>is not operational
TemperatureWarning12326
Temperature sensor is ok
Temperature sensor \<string>\ at <string>is operational: current temperature is<decimal> C
TemperatureInformation12327
Fan in high speed
Fan \<string>\ at <string> <string> is run-ning fast: current speed <decimal> rpm
Cooling FanInformation12328
Fan in low speed
Fan \<string>\ at <string> <string> is run-ning slow: current speed <decimal> rpm
Cooling FanInformation12329
Fan is ok
Fan \<string>\ at <string> <string> is nowrunning at speed <decimal> rpm
Cooling FanInformation12330
Fan stopped
Fan \<string>\ at <string> <string> stoppedworking
Cooling FanWarning12331
Fan missing
Fan \<string>\ at <string> <string> ismissing
Cooling FanWarning12332
Power supply fail
Power supply \<string>\ at <string> iseither not connected or failed
Power SupplyWarning12333
Power supply missing
Power supply \<string>\ at <string> ismissing
Power SupplyWarning12334
Power supply is ok
Power supply \<string>\ at <string> is ok
Power SupplyInformation12335
28Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
System temperature is warm
current temperature for sensor \<string>\on shelf \<string>\ at <string> is <decimal>C
TemperatureWarning12336
System temperature is cold
current temperature for sensor \<string>\on shelf \<string>\ at <string> is <decimal>C
TemperatureWarning12337
System temperature is OK
System temperature is now within range:current temperature for sensor \<string>\on shelf \<string>\ at <string> is <decimal>C
TemperatureInformation12338
Temperature sensor failed
Temperature sensor \<string>\ on shelf\<string>\ at <string> has failed
TemperatureWarning12339
Temperature sensor is OK
Temperature sensor \<string>\ on shelf\<string>\ at <string> is operational: currenttemperature is <decimal> C
TemperatureInformation12340
Fan is at high speed
Fan \<string>\ on shelf \<string>\ at<string> <string> is running fast: currentspeed <decimal> rpm
Cooling FanInformation12341
Fan is at low speed
Fan \<string>\ on shelf \<string>\ at<string> <string> is running slow: currentspeed <decimal> rpm
Cooling FanInformation12342
Fan is OK
Fan \<string>\ on shelf \<string>\ at<string> <string> is now running at speed<decimal> rpm
Cooling FanInformation12343
Fan stopped
Fan \<string>\ on shelf \<string>\ at<string> <string> stopped working
Cooling FanWarning12344
Fan missing
Fan \<string>\ on shelf \<string>\ at<string> <string> is missing
Cooling FanWarning12345
29Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Power supply fail
Power supply \<string>\ on shelf \<string>\at <string> is not connected or has failed
Power SupplyWarning12346
Power supply missing
Power supply \<string>\ on shelf \<string>\at <string> is missing
Power SupplyWarning12347
Power supply is OK
Power supply \<string>\ on shelf \<string>\at <string> is OK
Power SupplyInformation12348
NVRAM battery is charging
NVRAM battery is charging on controller<string>
NVRAMWarning12601
NVRAM battery has finished charging
NVRAM battery has finished charging oncontroller <string>
NVRAMInformation12602
NVRAM version is incompatible
NVRAM version is incompatible with sys-tem firmware on controller <string>
NVRAMCritical12603
NVRAM card multi-bit error (MBE) detec-ted
The NVRAM memory content is corruptedon controller <string>
NVRAMError12604
NVRAM card single-bit error (SBE) detec-ted
The NVRAM memory content is experien-cing bit flips on controller <string>
NVRAMWarning12605
NVRAM card non-correctable multi-bit er-ror (MBE) detected
The NVRAM memory content has experi-enced a non-correctable bit flip error oncontroller <string>
NVRAMError12606
NVRAM card correctable single-bit error(SBE) detected
The NVRAM memory content has experi-enced a correctable bit flip error on control-ler <string>
NVRAMWarning12607
30Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
NVDIMM reserved flash blocks reachedthe upper threshold
The reserved flash blocks have reachedthe upper threshold (remaining = <decim-al>) on controller <string>.
NVRAMInformation12608
NVDIMM reserved flash blocks reachedthe lower threshold
The reserved flash blocks have reachedthe lower threshold (remaining = <decim-al>) on controller <string>. Please contactNimble Storage Support.
NVRAMWarning12609
NVDIMM ultracap cacapcitance dis-charged
The NVDIMM ultracap capacitance is dis-charged (remaining = <decimal>) on con-troller <string>
NVRAMWarning12610
NTB_BAD_LINK
Controller <string> <string> in <string> ishigher than the threshold value of<decimal>. Please Contact Nimble StorageSupport.
NTBCritical12611
NVDIMM ultracap capacitance discharged
The NVDIMM ultracap capacitance is dis-charged (remaining = <decimal>) on con-troller <string>. Please Contact NimbleStorage Support.
NVRAMWarning12612
NVRAM module missing
NVRAM module is not detected on control-ler <string>. Please contact Nimble Stor-age Support.
NVRAMCritical12613
NVDIMM ultracap capacitance discharged
The NVDIMM ultracap capacitance is dis-charged on controller <string>. Data isunsafe if power is lost. If this situationcontinues for <decimal> minutes
NVRAMCritical12614
Shelf controller connected to wrong sideof host controller
Controller <string> of Shelf location<string>
ShelfWarning12701
31Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Shelf SES device not ready
SES device not ready for shelf serial<string> location <string>
ShelfError12702
SAS link of a shelf slot is degraded
SAS link of shelf serial <string> location<string> slot <string> is degraded
ShelfWarning12703
Not enough disk in shelf
Shelf serial <string> location <string> doesnot have enough number of disks
ShelfWarning12704
System cannot read shelf serial number
System cannot read the serial numberfrom shelf at location <string>
ShelfError12705
SAS cable connected to wrong port
SAS cable s) that connected to shelf loca-tion <string> is(are) connected to thewrong port(s
ShelfError12706
SAS link(s) between the shelves is(are)degraded
SAS link(s) between shelf location <string>and <string> is(are) degraded
ShelfWarning12707
SAS expander error
SAS expander in shelf at location <string>
ShelfWarning12708
Shelf SAS loop detected
Both shelf controllers A and B are connec-ted to the same head controller at location<string> and <string>. Ensure that eachcontroller on the shelf is connected to itshead unit equivalent (A or B)
ShelfError12709
Shelf appear only on one side of hostcontrollers
Shelf serial <string> visible on host control-ler <string> location <string> but not onhost controller <string>
ShelfWarning12710
Shelf controller connection order mis-matched
Shelf serial <string> is at location <string>on host controller A but at location <string>on host controller B. Connect both control-lers on each shelf to the head or shelf inthe same order
ShelfWarning12711
32Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Cannot access shelf SES device
Cannot access shelf SES device in theshelf serial <string> at location <string>
ShelfError12712
Controller failover due to shelf problem
Controller failover due to shelf problem
ShelfInformation12713
New Shelf detected
A new shelf is detected at location<string>.
ShelfInformation12714
Shelf is disconnected
Shelf at location <string>
ShelfInformation12715
Shelf chassis swap detected
Shelf serial <string> location <string> re-placed shelf serial <string>
ShelfWarning12716
Shelf daisy chain too long
Shelf serial <string> location <string> ex-ceeds maximum supported daisy chainlength
ShelfWarning12717
Connection to shelf is restored
SAS connection to shelf at location<string>
ShelfInformation12719
SAS link disabled
SAS phy <string> on shelf at location<string> has excessive link error and hasbeen disabled
ShelfWarning12720
Excessive link error on disk
SAS link between disk sn <string> andexpander <string> has excessive link error
ShelfWarning12721
SAS cable connected to wrong port
SAS cable s) that connected to shelf loca-tion <string> is(are) connected to thewrong port(s
ShelfError12730
Cannot access shelf SES device
Cannot access shelf SES device in theshelf serial <string> at location <string>
ShelfError12731
33Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
SAS link disabled
SAS phy <string> on shelf at location<string> has excessive link errors and hasbeen disabled.
ShelfWarning12732
Excessive link error on disk
SAS link between disk S/N <string> andexpander <string> has excessive link er-rors. Contact Nimble Storage Support.
ShelfWarning12733
SAS cable connected to wrong port
SAS cable s) that connected to shelf loca-tion <string> is(are) connected to thewrong port(s
ShelfWarning12734
Cannot access shelf SES device
Cannot access shelf SES device in theshelf serial <string> at location <string>
ShelfWarning12735
Cannot access shelf SES device
Cannot access shelf SES device in theshelf serial <string> at location <string>
ShelfWarning12736
Cannot access shelf SES device
Cannot access shelf SES device in theshelf with S/N <string> at location <string>.Some sensor data may not be available.Contact Nimble Storage Support.
ShelfWarning12738
Cannot access shelf IPMI device
Cannot access shelf IPMI device in theshelf with S/N <string> at location <string>.Some sensor data may not be available.Contact Nimble Storage Support.
ShelfWarning12740
SAS cable connected to wrong port
SAS cable between shelf location <string>and location <string> is connected towrong port.
ShelfWarning12741
Physical memory detected is less than in-stalled
Physical memory detected is less than in-stalled on array serial number <string>controller <string>. Installed <decimal> GB
ControllerCritical12901
CS-Model changed
The CS-Model has changed. The modelis now <string>.
ArrayNote14000
34Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
CS-Model unknown
The system cannot determine the CS-Model. The prior model was <string>
ArrayWarning14001
The system temperature is beginning toexceed the allowable operating temperat-ure. If it continues to exceed allowed oper-ating temperature
the system may shut down.
TemperatureWarning14002
Controller shutdown occurred due to ex-cessive temperature
Temperature exceeds maximum operatingtemperature (50 Celsius) on controller<string>
TemperatureCritical14003
Controller exceeds allowable operatingtemperature
Temperature exceeds allowable operatingtemperature on controller <string>(<decimal> Celsius)
TemperatureCritical14004
Backplane exceeds allowable operatingtemperature
Temperature exceeds allowable operatingtemperature on backplane (<decimal>Celsius)
TemperatureCritical14005
System temperature is too high.
Sensor <string> on shelf <string> at<string> is <decimal> Celsius. If anysensor exceeds 50 degrees C
TemperatureWarning14006
System temperature continues to be high.
Temperature Sensor on shelf <string> is<decimal> Celsius. If any sensor exceeds50 degrees C
TemperatureCritical14007
Power supply down revisioned
While your shelf <string> continues tofunction normally
Power SupplyCritical14008
Controller shutdown occurred due to ex-cessive temperature
Temperature exceeds maximum operatingtemperature (<decimal>) on controller<string>
TemperatureCritical14009
35Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Power supply down revisioned
While your shelf <string> continues tofunction normally
Power SupplyCritical14010
Array temperature is too high
Temperature sensor <string> on shelf<string> at <string> is <decimal> Celsius.Check air temperature and air flow aroundthe array.
TemperatureWarning14011
Array temperature continues to be high
Temperature sensor on shelf <string> is<decimal> Celsius. The shelf shuts downif it exceeds the maximum operating tem-perature.
TemperatureCritical14012
Power supply status unavailable
Array software is unable to query statusof power supply units (PSUs). Althoughthe shelf S/N <string> continues to functionnormally
Power SupplyCritical14013
Power supply status unavailable
Unable to query status of power supplyunits (PSUs). Although the shelf S/N<string> continues to function normally
Power SupplyCritical14014
An unknown firmware version was detec-ted
An unknown firmware version was detec-ted for component <string> on controller<string>
ControllerError14200
Fibre Channel link up
Fibre Channel link up on controller <string>port <string>
FCInformation14400
Fibre Channel link down
Fibre Channel link down on controller<string> port <string>
FCWarning14401
Fibre Channel link not connected
Fibre Channel link not connected on con-troller <string> port <string>
FCInformation14402
Fibre Channel link up with connection tofabric
Fibre Channel link up with connection tofabric on controller <string> port <string>.
FCInformation14403
36Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Hardware
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Fibre Channel link up with no connectionto fabric
Fibre Channel link up with no connectionto fabric on controller <string> port<string>. Check the switch log files for er-rors.
FCWarning14404
Table 5: Alert Replication
Replication
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Replication succeeded
Successfully replicated snapshot collection<string> to partner <string>
PartnerInformation11000
Excessive replication delay
Excessive delay replicating volume collec-tion <string> to partner <string>
PartnerInformation11001
Excessive replication delay
Excessive delay replicating volume collec-tion <string> to partner <string>
PartnerWarning11002
Partner synchronization failed
Failed to synchronize replication configur-ation to partner <string>
PartnerWarning11003
Volume replication stalled
Replication is stalled. Volume <string> onpartner <string> must be removed in orderto proceed
PartnerWarning11004
Volume collection handover completed
Completed handover of volume collection<string>
PartnerInformation11005
Replication between multi-array scaleoutgroup and pre-scaleout array is not suppor-ted
Cannot replicate from/to the pre-2.x part-ner <string> from a multi-array group
PartnerWarning11006
Replication between a scaleout group andpre-scaleout array must be configured overthe management network
Cannot replicate from/to the pre-2.x part-ner <string> over the data network.
PartnerWarning11007
37Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Replication
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Replication resynchronized
Successfully resynchronized while replic-ating snapshot <string> on volume<string> from partner <string>. Priorsnapshots for this volume may be out ofsync. Please contact Nimble StorageSupport.
PartnerError11008
Resynchronization not supported
Downstream partner <string> has reques-ted resynchronization of replicated snap-shots for volume <string>. Please contactNimble Technical Support for assistance.
PartnerWarning11009
Resynchronization not supported
Volume <string> needs resynchronizationfrom upstream partner <string>. ContactNimble Storage Support.
PartnerWarning11010
Replication resynchronized
Successfully resynchronized while replic-ating snapshot <string> on volume<string> from partner <string>. Priorsnapshots for this volume may be out ofsync. Contact Nimble Storage Support.
PartnerError11011
Resynchronization not supported
Downstream partner <string> has reques-ted resynchronization of replicated snap-shots for volume <string>. Contact NimbleStorage Support.
PartnerWarning11012
Partner authentication failed
Failed to authenticate with replicationpartner <string> because partner secretsdo not match. Replication is currentlypaused. Edit the partner’s shared secretto resume replication.
PartnerWarning11013
Replicated snapshot resynchronized
Successfully resynchronized replicatedsnapshot <string> of volume <string> frompartner <string>. Prior snapshots for thisvolume may not be synchronized. ContactNimble Storage Support.
PartnerWarning11014
38Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Replication
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Replicated snapshot resynchronization notsupported
Downstream partner <string> has reques-ted resynchronization of replicated snap-shots for volume <string>. This group doesnot support resynchronization. ContactNimble Storage Support.
PartnerWarning11015
Replication partner authentication failed
Failed to authenticate with replicationpartner <string> because shared secretdoes not match. Replication is currentlypaused. Edit partner and match the sharedsecret to resume replication.
PartnerWarning11016
Replicated volume needs resynchroniza-tion
Snapshot <string> of volume <string>needs resynchronization from upstreampartner. Contact Nimble Storage Support.
VolumeError11017
Volume collection handover aborted
Aborted handover of volume collection<string>
PartnerInformation11018
Volume collection handover completedwith errors.
Completed handover of volume collection<string>
PartnerInformation11019
Volume collection handover aborted witherrors.
Aborted handover of volume collection<string>
PartnerInformation11020
Table 6: Alert Service
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Low writable space
The system is low on writable space. Writeoperations will be slowed.
ArrayWarning0101
Writable space reclaimed
Writable space is sufficient
ArrayInformation0102
39Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Critically low writable space
The system is extremely low on writablespace
ArrayCritical0103
High system utilization
The system is currently <decimal>% full.Consider deleting unneeded snapshots orvolumes to reduce space usage.
ArrayWarning0104
System utilization OK
The system is down to <decimal>% utiliz-ation.
ArrayInformation0105
Critically high system utilization
The system is currently <decimal>% full.Consider deleting unneeded snapshots orvolumes to reduce space usage.
ArrayCritical0106
Critically low writable space
The system's writable space is extremelylow. Application writes will be progressivelyslowed as writable space continues to de-cline.
ArrayCritical0107
Critically low writable space
The system's writable space is too low forwrite operations. Application writes willtime out.
ArrayCritical0110
Critically low writable space
The array's writable space is extremelylow. Application writes will be progressivelyslowed as writable space continues to de-cline.
ArrayCritical0111
Critically low writable space
The array's writable space is too low forwrite operations. Application writes willtime out.
ArrayCritical0112
Critically high system utilization
The system is extremely low on space.Incoming writes will be denied.
ArrayCritical0113
Unhandled controller exception
Unhandled exception on controller <string>
ControllerCritical2001
Controller takeover occurred
Takeover occurred on controller <string>
ControllerInformation2002
40Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Standby controller available
Standby controller <string> available
ControllerInformation2003
Standby controller not available
Standby controller <string> not available
ControllerWarning2004
Excessive controller restarts detected
Excessive controller <string> restarts de-tected
ControllerCritical2005
Restarting controller to recover service
Restarting controller <string> to recover<string> service
ControllerCritical2006
Rebooting controller on user request
Rebooting controller <string> on user re-quest
ControllerInformation2007
Failed to reboot controller per user request
Failed to reboot controller <string> peruser request
ControllerError2008
Halting controller on user request
Halting controller <string> on user request
ControllerInformation2009
Failed to halt controller per user request
Failed to halt controller <string> per userrequest
ControllerError2010
Standby controller not available
Standby controller <string> not available
ControllerInformation2011
Standby controller not available for an ex-tended period
Standby controller <string> not availablefor an extended period
ControllerWarning2012
Unhandled controller exception
Unhandled exception on controller <string>
ControllerWarning2013
Unhandled controller exception
all services are down
ControllerCritical2014
Standby controller not available for an ex-tended period
Standby controller <string> not availablefor <decimal> minutes
ControllerWarning2015
41Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Standby controller not available for an ex-tended period
Standby controller <string> not availablefor <decimal> minutes
ControllerCritical2016
Controller takeover occurred
Takeover occurred on controller <string>
ControllerWarning2017
Controller failover occurred
Failover occurred on controller <string>
ControllerInformation2018
Controller failover occurred
Failover of active role occurred on control-ler <string>
ControllerInformation2019
Controller running with watchdog disabled
Watchdog disabled on controller <string>.Disconnect all connected clients and con-tact Nimble Storage Support immediately.
ControllerCritical2020
Service started
System services started. Software versionis <string>
ServiceInformation2101
Service stopped unexpectedly
restarting
ServiceInformation2102
Service stopped unexpectedly
not restarting
ServiceWarning2103
Created secure tunnel to Nimble Storagesupport
Created secure tunnel to Nimble Storagesupport on controller <string>
ServiceInformation2104
Tunnel to Nimble Storage support hasbeen terminated
Tunnel to Nimble Storage support hasbeen terminated on controller <string>
ServiceInformation2105
Service stopped unexpectedly
The <string> stopped unexpectedly on thearray
ServiceWarning2106
Service stopped unexpectedly
The <string> stopped unexpectedly on thearray
ServiceWarning2107
42Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to send alert e-mail
Failed to send e-mail to <string>
ServiceWarning2108
Failed to send alert e-mail
Failed to send alert e-mail to SMTP server.Verify SMTP server and port configuration.
ServiceWarning2109
Service manually disabled
The <string> was manually disabled on anarray controller and will not be started.
ServiceWarning2110
Created secure tunnel to Nimble StorageSupport
Created secure tunnel to Nimble StorageSupport on controller <string>.
ServiceInformation2111
Tunnel to Nimble Storage Support hasbeen terminated
Tunnel to Nimble Storage Support hasbeen terminated on controller <string>.
ServiceInformation2112
A member array became unreachable
Member array <string> became unreach-able
ArrayCritical10010
A member array became reachable
Member array <string> became reachable
ArrayInformation10011
A member array is unreachable
Member array <string> is unreachable
ArrayCritical10012
A member array is reachable
Member array <string> is reachable
ArrayInformation10013
Failed to assign array to pool
Failed to assign array <string> to pool.Please retry after verifying that array is upand has network connectivity.
PoolError10229
Failed to unassign array from pool
Failed to unassign array <string> frompool. Please retry after verifying that arrayis up and has network connectivity.
PoolError10230
43Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to merge pools.
Failed to merge pool <string> into pool.Please retry after verifying that all arraysin both pools are up and have networkconnectivity.
PoolError10240
Completed unassign of array from pool
Completed unassign of array <string> frompool. All data on the array has been movedto other arrays in the pool. The array cannow be assigned to other pools or re-moved from the group.
PoolInformation10252
Completed unassign of array from pool
Completed unassign of array <string> frompool <string>. All data on the array hasbeen moved to other arrays in the pool.The array can now be assigned to otherpools or removed from the group.
PoolInformation10253
Failed to assign array to pool
Failed to assign array <string> to pool<string>. Retry after verifying that array isup and has network connectivity.
PoolWarning10256
Failed to unassign array from pool
Failed to unassign array <string> from pool<string>. Retry after verifying that array isup and has network connectivity.
PoolWarning10257
Failed to merge pools.
Failed to merge pool <string> into pool<string>. Retry after verifying that all arraysin both pools are up and have networkconnectivity.
PoolError10260
Insufficient cache capacity in the pool forcache pinned volumes
Cache capacity <decimal> MB in pool<string> is insufficient to keep all cachepinned volumes in cache. Consider addingmore cache or unpinning some volumesto restore performance guarantees forcache pinned volumes.
VolumeCritical10282
Used space above warning limit
The amount of used space has reached<decimal>% of free space
ArrayWarning10401
44Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Used space below warning limits
The amount of used space is below<decimal>% of free space
ArrayInformation10402
Used space above critical level
The amount of used space has reached acritical level at <decimal>% of free space.Volumes above their reserve will be takenoffline once the free space has been ex-hausted
ArrayCritical10403
Used space below critical limits
The amount of used space is at <decim-al>% of free space. Volumes above theirreserve will be taken offline once the freespace has been exhausted
ArrayInformation10404
Array space utilization OK
The Array is down to <decimal>% spaceutilization.
ArrayInformation10405
High array space utilization
The array space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
ArrayInformation10406
High array space utilization
The array space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
ArrayWarning10407
Critically high array space utilization
The array space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
ArrayCritical10408
Used space in the pool above warninglimit
The amount of used space in the pool hasreached <decimal>% of free space
PoolWarning10409
Used space in the pool below warninglimits
The amount of used space in the pool isbelow <decimal>% of free space
PoolInformation10410
45Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Used space in the pool above critical level
The amount of used space in the pool hasreached a critical level at <decimal>% offree space. Volumes above their reservewill be taken offline once the free spacehas been exhausted
PoolCritical10411
Used space in the pool below critical limits
The amount of used space in the pool isat <decimal>% of free space. Volumesabove their reserve will be taken offlineonce the free space has been exhausted
PoolInformation10412
Pool space utilization OK
The pool is down to <decimal>% spaceutilization.
PoolInformation10413
High pool space utilization
The pool space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
PoolInformation10414
High pool space utilization
The pool space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
PoolWarning10415
Critically high pool space utilization
The pool space is currently <decimal>%full. Consider deleting unneeded snap-shots or volumes to reduce space usage.
PoolCritical10416
Used space in the pool above warninglimit
The amount of used space in the pool<string> has reached <decimal>% of freespace.
PoolWarning10417
Used space in the pool below warninglimits
The amount of used space in the pool<string> is below <decimal>% of freespace.
PoolInformation10418
46Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Used space in the pool above critical level
The amount of used space in the pool<string> has reached a critical level at<decimal>% of free space. Volumes abovetheir reserve will be taken offline once thefree space has been exhausted.
PoolCritical10419
Used space in the pool below critical limits
The amount of used space in the pool<string> is at <decimal>% of free space.Volumes above their reserve will be takenoffline once the free space has been ex-hausted.
PoolInformation10420
Pool space utilization OK
The pool <string> is down to <decimal>%space utilization.
PoolInformation10421
High pool space utilization
The pool space in pool <string> is currently<decimal>% full. Consider deleting un-needed snapshots or volumes to reducespace usage.
PoolInformation10422
High pool space utilization
The pool space in pool <string> is currently<decimal>% full. Consider deleting un-needed snapshots or volumes to reducespace usage.
PoolWarning10423
Critically high pool space utilization
The pool space in pool <string> is currently<decimal>% full. Consider deleting un-needed snapshots or volumes to reducespace usage.
PoolCritical10424
RAID array degraded
RAID array degraded by <decimal><string>
RaidWarning12400
RAID array rebuild started
RAID array started rebuilding disk <string>
RaidInformation12401
RAID array rebuild is done
RAID array has successfully completedrebuilding disk <string>
RaidInformation12402
47Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
RAID array rebuild failed
Failed to rebuild RAID array on disk<string>
RaidWarning12403
RAID array rebuild failed
Failed to rebuild RAID array on disk<string>
RaidWarning12404
Disks missing from RAID array
<decimal> <string> missing from RAIDarray
RaidWarning12405
Disk marked as spare
Disk <string> is marked as spare
RaidInformation12406
Could not assemble RAID array
Could not assemble RAID array
RaidCritical12407
RAID array degraded
RAID array degraded by <decimal><string> on <string> shelf <string>
RaidWarning12408
RAID array rebuild started
RAID array started rebuilding disk <string>on <string> shelf <string>
RaidInformation12409
RAID array rebuild is done
RAID array has successfully completedrebuilding disk <string> on <string> shelf<string>
RaidInformation12410
RAID array rebuild failed
Failed to rebuild RAID array from <string>shelf <string> on disk <string>
RaidWarning12411
RAID array rebuild failed
Failed to rebuild RAID array from <string>shelf <string> on disk <string>
RaidWarning12412
Disks missing from RAID array
<decimal> <string> missing from RAIDarray on <string> shelf <string>
RaidWarning12413
Disk marked as spare
Disk <string> is marked as spare on<string> shelf <string>
RaidInformation12414
48Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Could not assemble RAID array
Could not assemble RAID array on<string> shelf <string>
RaidCritical12415
RAID array rebuild scheduled
RAID array rebuild scheduled on disk<string> of <string> shelf <string>
RaidInformation12416
RAID array rebuild stopped
RAID array rebuild stopped on disk<string> of <string> shelf <string>
RaidInformation12417
Too many iscsi connections
iscsi login rejected from <string>
iSCSIWarning12501
Too many unaligned iscsi reads/writes
unaligned reads/writes percentage %/%
iSCSIWarning12502
Too many iSCSI connections
iSCSI login rejected from <string>
iSCSIWarning12504
Too many unaligned iSCSI reads/writes
unaligned reads/writes percentage %/%
iSCSIWarning12505
Too many iSCSI connections
iSCSI login from <string> is rejected
iSCSIWarning12506
New shelf is activated
Shelf serial <string> at location <decimal>has been activated
ShelfInformation12718
New shelf is activated
Shelf serial <string> at location <string>has been activated
ShelfInformation12737
New shelf activated
Shelf with S/N <string> at location <string>was activated
ShelfInformation12739
Group Leader role takeover succeeded
Successfully takenover group leader rolefrom array '<string>' (serial: <string>)
ArrayInformation13501
Group Leader role takeover succeeded
Array <string> (serial: <string>) success-fully took over group leader role from array<string> (serial: <string>)
ArrayInformation13504
49Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Group Leader role take over succeeded
Array <string> S/N <string> is now thegroup leader. Previous group leader wasarray <string> S/N <string>.
ArrayInformation13505
Group Leader role migrate failed
Array <string> S/N: <string> failed to mi-grate group leader role to array <string>S/N: <string>.
ArrayError13506
Group Leader role takeover has been re-jected by a member array
Group Leader role takeover has been re-jectec by member array '<string>'
ArrayError13502
Group Leader role takeover has been re-jected by a member array
Group Leader role takeover has been re-jected by member array '<string>'
ArrayError13503
Group merge completed successfully
Group merge with group <string> com-pleted successfully
GroupInformation13601
Failed to stop services on source groupfor group merge
Failed to stop services on source group<string> for group merge. Group mergeoperation would be rolled back. Retry theoperation later.
GroupWarning13602
Completed rollback of group merge opera-tion
Completed rollback of group merge opera-tion with group <string>. Services on group<string> have been resumed.
GroupInformation13603
Group merge operation is not complete onsome arrays
operation would be retried
GroupWarning13604
Failed to merge configuration from sourcegroup
Failed to merge configuration from sourcegroup <string>. Group merge operationwould be rolled back. Retry the operationlater.
GroupWarning13605
50Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Service
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Data Migration is getting delayed becauseof continuous restarts
Data Migration is getting delayed becauseof continuous restarts. Contact Support.
GroupWarning13701
Data migration is delayed because of re-peated restarts
Data migration is delayed because of re-peated restarts. Contact Nimble StorageSupport.
GroupWarning13702
Oldest events removed from the system
Total number of events reached <decim-al>. Maximum retention count is <decim-al>. The oldest <decimal> events removed.
ServiceWarning14700
Events count reached warning threshold
Events count reached warning thresholdof <decimal> events. If the number ofevents reaches the maximum retentioncount of <decimal>
ServiceWarning14701
Oldest audit log records removed from thesystem
Total number of audit log records reached<decimal>. Maximum retention count is<decimal>. The oldest <decimal> audit logrecords removed.
ServiceWarning14702
Audit log records count reached warningthreshold
Audit log records count reached warningthreshold of <decimal>. If the number ofaudit log records reaches the maximumretention count of <decimal>
ServiceWarning14703
Root Login succeeded.
Root Login to controller <string> from<string> succeeded.
ControllerWarning14800
Root Login failed.
Root Login to controller <string> from<string> failed.
ControllerCritical14801
51Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Table 7: Alert Test
Test
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Test alert
Test message at debug level
TestDBG5000
Test alert
Test message at info level
TestInformation5001
Test alert
Test message at error level
TestError5002
Test alert
Test message at \not\ level
TestNote5003
Test alert
Test message at note level
TestNote5004
Test alert
Test message at warn level
TestWarning5005
Test alert
Test message at critical level
TestCritical5006
Table 8: Alert Unknown
Unknown
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Cache cleared by user
Cache cleared by user
ArrayInformation10101
Table 9: Alert Update
Update
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Unpacking update package failed
Unpacking update package failed on con-troller <string>: <string>
ControllerError6000
Software update started
Software update to version <string> startedon controller <string>
ControllerInformation6001
Reverting software to previous version
Reverting software to previous version<string> on controller <string>
ControllerError6002
52Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Update
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Successfully updated software
Successfully updated software to version<string> on controller <string>
ControllerInformation6003
Rolling back software
Rolling back software to version <string>on controller <string>
ControllerInformation6004
Update package pre-check failed
Update package Pre-check failed on con-troller <string>
ControllerError6005
Software update failed
Software update failed: <string>
ArrayError6007
Unpacking update package
Unpacking version <string> update pack-age on controller <string>
ControllerInformation6008
Unpacked update package
Unpacked version <string> update pack-age on controller <string>
ControllerInformation6009
Software update reboot
<string> on controller <string>
ControllerInformation6010
Failed to download software update pack-age
Failed to download software update pack-age: <string>
ArrayError6011
Software update failed. \/tmp\ is full
Software update failed. \/tmp\ on controller<string> is full
ControllerError6012
Software update failed. scratch space isfull
Software update failed. scratch space oncontroller <string> is full
ControllerError6013
Software update failed. \/var\ is full
Software update failed. \/var\ on controller<string> is full
ControllerError6014
Software update failed. Configurationspace is full
Software update failed. Configurationspace on controller <string> is full
ControllerError6015
53Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Update
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Software update failed. Recovery OSspace is full
Software update failed. Recovery OSspace is full on controller <string> is full
ControllerError6016
Software update package was not found
Software update package <string> wasnot found on controller <string>
ControllerError6017
Software update package has wrong sig-nature
Software update package <string> on<string> controller <string> has wrongsignature
ControllerError6018
Software update package has wrongchecksum
Software update package <string> on<string> controller has wrong checksum
ControllerError6019
Software update precheck failed. Networkconnectivity will degrade after softwareupdate
Software udpate precheck failed. Networkconnectivity will degrade on controller<string> after software update
ControllerError6020
Software update failed. Update cannot beapplied while services cannot be failedover to other controller
Software update failed. Update cannot beapplied while services cannot be failedover to other controller. Controller <string>is not in standby mode and cannot takeover services.
ControllerError6021
Software update cannot be applied.
Software update cannot be applied. Con-troller <string> is not in standby mode andcannot take over services that are requiredfor a successful update.
ControllerError6022
Software update precheck failed. Networkconnectivity will degrade after softwareupdate
Software update precheck failed. Networkconnectivity will degrade on controller<string> after software update
ControllerError6023
54Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Update
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Software update precheck failed. RAIDassembly failed on standby controller andprevents software update to proceed
Software update precheck failed. RAIDassembly failed on standby controller<string> and prevents software update toproceed
ControllerError6024
Failed to contact a member array duringsoftware update
Failed to contact member <string> duringsoftware update
ArrayWarning6501
Failed to update software on a memberarray
Failed to update software on member array<string>
ArrayWarning6502
Software update on a member array timedout
Software update on member array <string>timed out after <decimal> minutes
ArrayWarning6503
Table 10: Alert Volume
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume space usage over warning limit
Volume <string> space usage is over theconfigured warning limit
VolumeWarning10200
Volume space usage below warning limit
Volume <string> space usage is now be-low the configured warning limit
VolumeInformation10201
Volume space usage over quota
Volume <string> space usage is over theconfigured quota
VolumeError10202
Volume space usage below quota
Volume <string> space usage is now be-low the configured quota
VolumeInformation10203
Volume snapshot space usage overwarning limit
Volume <string> snapshot space usage isover the configured warning limit
VolumeWarning10204
55Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume snapshot space usage belowwarning limit
Volume <string> snapshot space usage isnow below the configured warning limit
VolumeInformation10205
Volume snapshot space usage over quota
Volume <string> snapshot space usage isover the configured quota
VolumeError10206
Volume snapshot space usage belowquota
Volume <string> snapshot space usage isnow below the configured quota
VolumeInformation10207
Volume space usage approaching quota
Volume <string> space usage is at<decimal>% and approaching quota of<decimal>%. It will be taken offline if it ex-ceeds the quota
VolumeCritical10208
Volume space usage below critical limit
Volume <string> space usage at <decim-al>% is below critical limit
VolumeInformation10209
Volume snapshot space usage approach-ing quota
Volume <string> snapshot space usage isat <decimal>% and approaching quota. Itwill be taken offline if it exceeds the quota
VolumeCritical10210
Volume snapshot space usage below crit-ical limit
Volume <string> snapshot space usageat <decimal>% is below critical limit
VolumeInformation10211
Volume being taken offline because it isabove its quota
Volume <string> is being taken offline be-cause it is above its quota
VolumeCritical10212
The quota for volume is being set to100%because it is above its current quota
The quota for volume <string> is being setto 100%because it is above its quota. Thisis a one time action. Adjust volume quotasappropriately as the system now enforcesvolume quotas by taking offline volumeswith space usage above quota
VolumeWarning10213
56Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume being taken offline because it isabove its snapshot quota
Volume <string> is being taken offline be-cause it is above its snapshot quota
VolumeCritical10214
The snapshot quota for volume is beingset to unlimited because it is above itssnapshot quota
The snapshot quota for volume <string>is being set to unlimited because it isabove its snapshot quota. This is a onetime action. Adjust snapshot quotas appro-priately as the system now enforcesvolume snapshot quotas by taking offlinevolumes with snapshot space usage abovequota
VolumeWarning10215
Volume being taken offline because it isabove its reserve and system is out of freespace
Volume <string> is being taken offline be-cause it is above its reserve and systemis out of free space
VolumeCritical10216
Volume reserve is being set to zero be-cause it is above its reserve and systemis out of free space
Volume <string> reserve is being set tozero because it is above its reserve andsystem is out of free space. This is a onetime action. Adjust volume reserves appro-priately as the system now enforcesvolume reserves by taking offline volumeswith space usage above their reservewhen free space on the system is ex-hausted
VolumeWarning10217
Volume being taken offline because it isabove its snapshot reserve and system isout of free space
Volume <string> is being taken offline be-cause it is above its snapshot reserve andsystem is out of free space
VolumeCritical10218
57Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume snapshot reserve is being set tozero because it is above its reserve andsystem is out of free space
Volume <string> snapshot reserve is beingset to zero because it is above its reserveand system is out of free space. This is aone time action. Adjust volume snapshotreserves appropriately as the system nowenforces snapshot reserves by taking off-line volumes with snapshot space usageabove reserve when system is out of freespace
VolumeWarning10219
Volume space usage over warning limit
Volume <string> space usage at <decim-al>% is over the configured warning limitof <decimal>%
VolumeWarning10220
Volume space usage below warning limit
Volume <string> space usage at <decim-al>% is now below the configured warninglimit of <decimal>%
VolumeInformation10221
Volume space usage is over the con-figured quota
Volume <string> space usage at <decim-al>% is over the configured quota at<decimal>%
VolumeCritical10222
Volume space usage is now below theconfigured quota
Volume <string> space usage at <decim-al>% is now below the configured warninglimit of <decimal>%
VolumeInformation10223
Volume snapshot space usage overwarning limit
Volume <string> snapshot space usage isover the configured warning limit
VolumeWarning10224
Volume snapshot space usage belowwarning limit
Volume <string> snapshot space usage isnow below the configured warning limit
VolumeInformation10225
Volume snapshot space usage over quota
Volume <string> snapshot space usage isover the configured quota
VolumeCritical10226
58Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume snapshot space usage belowquota
Volume <string> snapshot space usage isnow below the configured quota
VolumeInformation10227
Volume attributes synchronization to ar-rays in the pool delayed
Volume <string> attributes synchronizationto arrays in the pool delayed. Will retry
VolumeWarning10228
Volume space usage approaching quota
Volume <string> space usage is at<decimal>% and approaching quota of<decimal>%.
VolumeWarning10231
Volume snapshot space usage approach-ing quota
Volume <string> snapshot space usage isat <decimal>% and approaching quota.
VolumeWarning10232
Volume space usage is above its reserve
Volume <string> space usage at <decim-al>% is above its reserve at <decimal>%.It will be taken offline once the free spacehas been exhausted.
VolumeWarning10233
Volume space usage is below its reserve
Volume <string> space usage at <decim-al>% is below its reserve at <decimal>%.
VolumeInformation10234
Volume snapshot space usage is aboveits reserve
Volume <string> snapshot space usageat <decimal>% is above its snapshot re-serve at <decimal>%. It will be taken off-line once the free space has been ex-hausted.
VolumeWarning10235
Volume snapshot space usage is belowits reserve
Volume <string> snapshot space usageat <decimal>% is below its snapshot re-serve at <decimal>%.
VolumeInformation10236
Volume attributes synchronization to ar-rays in the pool succeeded
Volume <string> attributes synchronizationto arrays in the pool succeeded.
VolumeInformation10241
59Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Snapshot attributes synchronization to ar-rays in the pool delayed
Snapshot <string> in Volume <string> at-tributes synchronization to arrays in thepool delayed. Will retry
VolumeWarning10242
Snapshot attributes synchronization to ar-rays in the pool succeeded
Snapshot <string> in Volume <string> at-tributes synchronization to arrays in thepool succeeded.
VolumeInformation10243
Volume completed move to destinationpool
Volume <string> completed move to des-tination pool <string>. Volume data is nowon destination pool.
VolumeInformation10250
Volume completed aborting move to des-tination pool
Volume <string> completed aborting moveto destination pool <string>. Volume datahas been moved back to source pool<string>.
VolumeInformation10251
Volume space usage approaching volumequota
Volume <string> space usage is at<decimal>% and approaching volumequota of <decimal>%. It will be set to non-writable if it exceeds the volume quota.
VolumeCritical10261
Volume being set to non-writable becauseit is above its volume quota
Volume <string> is being set to non-writ-able because it is above its volume quota.
VolumeCritical10262
Volume snapshot space usage approach-ing snapshot quota
Volume <string> snapshot space usage isat <decimal>% and approaching snapshotquota. It will be set to non-writable if it ex-ceeds the snapshot quota.
VolumeCritical10263
Volume being set to non-writable becauseit is above its snapshot quota
Volume <string> is being set to non-writ-able because it is above its snapshotquota.
VolumeCritical10264
60Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Volume being set to non-writable becauseit is above its reserve and system is out offree space
Volume <string> is being set to non-writ-able because it is above its reserve andsystem is out of free space
VolumeCritical10265
Volume being set to non-writable becauseit is above its snapshot reserve and systemis out of free space
Volume <string> is being set to non-writ-able because it is above its snapshot re-serve and system is out of free space
VolumeCritical10266
Invalid volume serial number detected
Volume <string> is being taken offline be-cause it is using an invalid serial number<string>. Contact Nimble Storage Support.
VolumeCritical10278
Invalid snapshot serial number detected
Snapshot <string> of volume <string> isbeing taken offline because it is using aninvalid serial number <string>. ContactNimble Storage Support.
VolumeCritical10279
Scheduled snapshot succeeded
Successfully snapshoted volumes associ-ated with volume collection <string>schedule <string>
Protection SetInformation10300
Scheduled snapshot failed
Failed to snapshot volumes associatedwith volume collection <string> schedule<string>
Protection SetWarning10301
Scheduled snapshot skipped
Skipped scheduled snapshot collection<string>
Protection SetInformation10302
Scheduled snapshot skipped
Skipped scheduled snapshot on volumesassociated with volume collection <string>schedule <string>
Protection SetInformation10303
Scheduled snapshot succeeded
Successfully snapshoted volumes associ-ated with volume collection <string>schedule <string>
Protection SetInformation10304
61Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the system isunable to log into the vCenter server dueto an incorrect user name <string> orpassword. Verify the user name andpassword are correct.
Protection SetWarning10305
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the connectionto the vCenter server <string> timed out.Verify the vCenter server name and IPaddress.
Protection SetWarning10306
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because vCenter server<string> refused the connection.
Protection SetWarning10307
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because vCenter server<string> is disconnected from the NimbleProtection Manager.
Protection SetWarning10308
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because no route wasfound to vCenter server <string>.
Protection SetWarning10309
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the socket readfrom vCenter server <string> timed out.
Protection SetWarning10310
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the network isunreachable.
Protection SetWarning10311
62Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because snapshots aredisabled. Some VMWare products
Protection SetWarning10312
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because <string> doesnot exist.
Protection SetWarning10313
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because <string> doesnot have permission to perform the opera-tion. Configure user with the proper permis-sions or log in as a user with such permis-sions.
Protection SetWarning10314
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the system wasunable to look up the vCenter server<string>. Verify the vCenter server nameor IP address.
Protection SetWarning10315
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> due to an encoding error
Protection SetWarning10316
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the serversocket was closed before a reply waswritten.
Protection SetWarning10317
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because no Datacenterexists.
Protection SetWarning10318
63Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because Nimble volumeserial number is empty.
Protection SetWarning10319
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> due to an unexpectederror.
Protection SetWarning10320
Scheduled snapshot succeeded withwarning
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the VMFSdatastore block size is not large enoughto accommodate the files in the VM. ForVMFS-5 datastore the maximum file sizeis 2TB minus 512 bytes. For the VMFS-3datastore the maximum file size will de-pend on the block size of the datastore.
Protection SetWarning10321
Scheduled snapshot succeeded
Successfully created snapshot of volumesassociated with volume collection <string>schedule <string>
Protection SetInformation10322
Scheduled snapshot succeeded
Successfully created snapshot of volumesassociated with volume collection <string>schedule <string>
Protection SetInformation10323
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because snapshots aredisabled. Some VMware products
Protection SetWarning10324
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> since the vCenter virtualmachine snapshot tasks have not yetcompleted.
Protection SetWarning10325
64Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Scheduled snapshot failed
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the snapshotname exceeds the maximum allowablelength on vCenter. Shorten the volumecollection name or schedule name.
Protection SetWarning10326
Application synchronization failed
Application synchronization failed forvolume collection <string> schedule<string>
Protection SetInformation10327
Scheduled snapshot failed.
Failed to snapshot volumes associatedwith volume collection <string>
Protection SetWarning10328
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because <string> does not havepermission to perform the operation. Con-figure user with the proper permissions orlog in as a user with such permissions.
Protection SetWarning10340
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because <string> does not exist.
Protection SetWarning10341
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> due to an encoding error
Protection SetWarning10342
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because the server socket wasclosed before a reply was written.
Protection SetWarning10343
65Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because no Datacenter exists.
Protection SetWarning10344
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because Nimble volume serialnumber is empty.
Protection SetWarning10345
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> due to an unexpected error.
Protection SetWarning10346
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because the VMFS datastoreblock size is not large enough to accom-modate the files in the VM. For VMFS-5datastore the maximum file size is 2TBminus 512 bytes. For the VMFS-3 data-store the maximum file size will depend onthe block size of the datastore.
Protection SetWarning10347
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because snapshots are disabled.Some VMware products
Protection SetWarning10348
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> since the vCenter virtual machinesnapshot tasks have not yet completed.
Protection SetWarning10349
66Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because the snapshot name ex-ceeds the maximum allowable length onvCenter. Shorten the volume collectionname or schedule name.
Protection SetWarning10350
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> because virtual machine tools inthe guest are not running.
Protection SetWarning10351
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the IP addressor hostname <string> is not a valid vCenterserver.
Protection SetWarning10352
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string>. Too many vCentersynchronized snapshots are currently inprogress. Stagger the schedules forvCenter synchronized snapshots.
Protection SetWarning10353
Scheduled snapshot failed
Failed to create VSS synchronized snap-shot associated with volume collection<string> schedule <string>. Incompatibleversion of Nimble VSS service on the ap-plication server.
Protection SetWarning10354
67Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the system isunable to log into the vCenter server dueto an incorrect user name <string> orpassword. Verify the user name andpassword are correct.
Protection SetWarning10355
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the connectionto the vCenter server <string> timed out.Verify the vCenter server name and IPaddress.
Protection SetWarning10356
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because vCenter server<string> refused the connection.
Protection SetWarning10357
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because vCenter server<string> is disconnected from the NimbleProtection Manager.
Protection SetWarning10358
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because no route wasfound to vCenter server <string>.
Protection SetWarning10359
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the socket readfrom vCenter server <string> timed out.
Protection SetWarning10360
68Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the network isunreachable.
Protection SetWarning10361
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> because the system wasunable to look up the vCenter server<string>. Verify the vCenter server nameor IP address.
Protection SetWarning10362
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> due to an unexpectedconnection error.
Protection SetWarning10363
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> since the vCenter virtualmachine snapshot tasks have not yetcompleted.
Protection SetWarning10364
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> due to an unexpectederror.
Protection SetWarning10365
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> due to an unexpected error. SeevSphere Client to get details on the failureof the snapshot task for this VM.
Protection SetWarning10366
69Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Failed to synchronize with VMware vCen-ter
Failed to <string> vCenter snapshot asso-ciated with volume collection <string>schedule <string> for virtual machine<string> due to failure to quiesce the virtualmachine. See vSphere Client to get detailson the failure of the snapshot task for thisVM.
Protection SetWarning10367
Multi initiator login
iscsi login to volume <string> rejected from<string> - existing session from <string>
iSCSIInformation12500
Multi initiator login
iSCSI login to volume <string> rejectedfrom <string> - existing session from<string>
iSCSIInformation12503
iSCSI connections from initiator repeatedlyclosed by array due to improper target IPconfiguration
iSCSI connections from initiator <string>on volume <string> repeatedly closed byarray due to improper target IP configura-tion. Review iSCSI connection settings oninitiator and use the correct target IP.Consider using Nimble Connection Man-ager to manage initiator connections
iSCSIError12057
iSCSI connections from initiator repeatedlyclosed by array due to improper target IPconfiguration
iSCSI connections with source IP <string>and destination IP <string> from initiator<string> on volume <string> repeatedlyclosed by the array. Review iSCSI connec-tion settings on the initiator and use thecorrect target IP.
iSCSIError12508
Total number of volumes approachingsystem limit
Total number of volumes is <decimal>which is approaching system limit of<decimal>
ArrayWarning13101
70Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Volume
Description/Possible Cause/ActionsTypeSeverityAlert/Event
Total number of volumes below warningthreshold
Total number of volumes is <decimal>which is below warning threshold of<decimal>
ArrayInformation13102
71Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
SNMP Traps
Nimble SNMP FAQ
SNMP v1, v2, and v2cWhat versions of SNMP does Nimble support?
Not in the current version. UDP traps are supported.Are acknowledged traps (informs) supported?
Through the GUI using the Administration >SNMP menu or the CLI snmp command.
How can I configure SNMP?
Community name.What security features are supported?
One.How many trap recipients are supported on eachdevice?
No. In this release, the device only sends traps.Does the device receive and forward traps?
72Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Nimble SNMP FAQ
Regulatory Information
Regulatory Warnings
European Community, Australia, New Zealand
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which casethe user may be required to take adequate measures.
Israel
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which casethe user may be required to take adequate measures.
Korea
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which casethe user may be required to take adequate measures.
Taiwan
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which casethe user may be required to take adequate measures.
USA
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant toPart 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
73Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Regulatory Information
interference when the equipment is operated in a commercial environment. This equipment generates, uses,and can radiate radio frequency energy and, if not installed and used in accordance with the instructionmanual, may cause harmful interference to radio communications. Operation of this equipment in a residentialarea is likely to cause harmful interference in which case the user is required to correct the interference athis own expense.
74Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Regulatory Warnings
75Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.
Regulatory Warnings
Index
B
bindings 17
C
community string 5setting 5
configuring 5SNMP 5
G
global MIB variables 14
I
IANA number 7
M
MIB 4, 10, 14description of 4
variables 10, 14global 14overview 10volume-specific 10
N
nimbleTrapCode 17
O
OID 7
overview 4
P
polling 7
R
regulatory warnings 73RFC1155 4
S
setting 5SNMP 5
SNMP 5
T
traps 5, 17trap destination setting 5
traps:trap variables 17
V
variables 7, 10, 14global 14names 7overview 10volume-specific 10
volume-specific MIB variables 10
W
warnings 73
Copyright © 2010-2015 by Nimble Storage, Inc. All rights reserved.