smartsensor hd nema gasket aging - microsoft

13
SmartSensor HD NEMA Gasket Aging Test Report WX-501-0023 Wavetronix products mentioned: SmartSensor HD As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA gasket aging test on the SmartSensor HD between Febru- ary 24–March 7, 2006. The following report documents the results of the test and is unedited by Wavetronix. Environ Laboratories LLC 9725 Girard Avenue South Minneapolis, Minnesota 55431-2621

Upload: others

Post on 18-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

SmartSensor HD NEMA Gasket Aging

Test Report

WX-501-0023

Wavetronix products mentioned:SmartSensor HD

As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA gasket aging test on the SmartSensor HD between Febru-ary 24–March 7, 2006. The following report documents the results of the test and is unedited by Wavetronix.

Environ Laboratories LLC9725 Girard Avenue SouthMinneapolis, Minnesota 55431-2621

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 1 of 12 ENGINEERING REPORT NO. 32767-5

800-826-3710 • FAX 952-888-6345 • 952-888-7795 www.environlab.com

ENGINEERING REPORT NO. 32767-5

GASKET AGING TEST

for

WAVETRONIX LLC 380 SOUTH TECHNOLOGY CT.

LINDON, UT 84042

PREPARED BY:

Michael J. Caron Test Engineer

Tom P. Braun Test Engineer

APPROVED BY:

Bradley C. Czech Vice President

This document shall not be reproduced except in full, without the written authorization of Environ Laboratories LLC.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 2 of 12 ENGINEERING REPORT NO. 32767-5

REVISION HISTORY Revision Total Number

of Pages Date Description

-- 12 17 March 2008 Original

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 3 of 12 ENGINEERING REPORT NO. 32767-5

TEST DATES: Start: 2/24/2006 Completion: 3/7/2006

ENVIRON TEST NO.: 32767-5

PREPARED FOR:

WAVETRONIX LLC 380 SOUTH TECHNOLOGY CT. LINDON, UT 84042 ATTN: Mr. Don Christensen

PURCHASE ORDER NO.: 10981 PURCHASE DATE: 2/15/2006

GASKET AGING TEST 1.0 ABSTRACT

1.1 Object

Subject the supplied Gasket Material to the Gasket Aging Test outlined in NEMA 250, Section 5.14.1, as requested in Wavetronix LLC Purchase Order No. 10981, dated February 15, 2006.

1.2 Conclusions

On completion of testing, tensile strength values are greater than 75% of initial values. On average, elongation values are greater than 60% of initial values. Therefore, the test material samples were determined to have passed the requirements of NEMA 250, Section 5.14.

2.0 UNIT(S) TESTED

MANUFACTURER: WAVETRONIX LLC

DEVICE: Gasket Material for IQ2 Enclosures

MODEL/PART NO.: Untreated Samples Treated Samples

SERIAL NO.: Designated as 1, 2, 3, and 4 Designated as 5, 6, 7, and 8

The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 4 of 12 ENGINEERING REPORT NO. 32767-5

3.0 TEST REQUESTED

Subject the test samples to the Gasket Aging Test outlined in NEMA 250, Section 5.14.1, as follows: Gasket material used in a Type 2, 3, 3R, 3 RX, 3S, 3 SX 4, 4X, 5, 6, 6P, 12, 12K, or 13 enclosure shall be of such quality that test samples subjected to a temperature of 69° to 70°C (156 - 158°F) in circulating air for 168 hours have a tensile strength of not less than 75% and an elongation of not less than 60% of values determined for unaged test samples.

4.0 INSTRUMENTATION, PROCEDURE AND RESULTS

4.1 Instrumentation

All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z540-1-1994 and ISO/IEC 17025: 1999.

Equi

pmen

t Num

ber

Des

crip

tion

Man

ufac

ture

r

Mod

el N

umbe

r

Last

Cal

ibra

tion

Due

Cal

ibra

tion

Ran

ge

200-145 Temperature Controller

Watlow 982 8/29/2005 8/29/2007 -328º to +750ºF

200-174 Temperature Chart

Recorder

Partlow MRC 7000 12/12/2005 6/12/2006 -150º to +350ºF

500-034 Temperature Chamber

Tenney BTC-100350 N/A N/A -80º to +350ºF

740-065 Universal Testing Machine

Instron 4502 7/25/2005 1/25/2007 0 to 2250 lbs

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 5 of 12 ENGINEERING REPORT NO. 32767-5

4.2 Procedure

The test samples were placed inside the temperature chamber and subjected to a temperature of 70°C for a period of 168 hours. The samples were then stabilized at ambient conditions. The aged gasket and an unaged gasket were then subjected to a tensile test. Figure No. 1 depicts a temperature chart showing chamber temperature during a typical 24-hour period of exposure. Figure Nos. 2 through 5 include graphic and print-out test data. Photograph Nos. 1 and 2 provide views of the test setup.

4.3 Results

On completion of testing, tensile strength values are greater than 75% of initial values. On average, elongation values are greater than 60% of initial values. Therefore, the test material samples were determined to have passed the requirements of NEMA 250, Section 5.14.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 6 of 12 ENGINEERING REPORT NO. 32767-5

Figure No. 1: Temperature chart (°F) showing chamber temperature during a typical 24-hour period of exposure.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 7 of 12 ENGINEERING REPORT NO. 32767-5

Figure No. 2: Displacement data, non-aged samples.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 8 of 12 ENGINEERING REPORT NO. 32767-5

Figure No. 3: Test data, non-aged samples.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 9 of 12 ENGINEERING REPORT NO. 32767-5

Figure No. 4: Displacement data, aged samples.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 10 of 12 ENGINEERING REPORT NO. 32767-5

Figure No. 5: Test data, aged samples.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 11 of 12 ENGINEERING REPORT NO. 32767-5

Photograph No. 1: View of test sample ready for tensile test.

________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 12 of 12 ENGINEERING REPORT NO. 32767-5

Photograph No. 2: View of test sample ready for tensile test.