Page 1: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

2017

Smart DCR – GIDC - User Manual

July

Page 2: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 1 | 9

Index

S. No. Table of Contents Page Number

1. Introduction 2

2. Prominent process of the software 2

2.1 Online Building Plan Approval System Process 2

2.2 Smart DCR Scrutiny Process 2

3. Objectives 3

4. Scope of the system 3

5. Do’s and Dont’s 3

5.1 Do’s 3

5.2 Dont’s 4

6. Drawing file specifications 4

7. Precheck software 4

8. Procedure to create a drawing 5

8.1 Parameters to be drawn using LINE Objects 5

8.2 Parameters to be drawn using POLYLINE Objects 5

8.3 Parameters to be drawn using TEXT Objects 6

9.a Details of colour code format 7

9.b List of NON FSI text 8

10.

Annexure Parameters Snapshots 9

Page 3: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 2 | 9

1. INTRODUCTION Every industrial zone in the world is continually evolving and developing to meet its investor’s needs. An authority powered by government is controlling the development of these industrial areas to have a harmonious as well as infrastructural and technologically superior ecosystem for all. GIDC has been created for securing the orderly establishment and organization of industries in industrial areas and industrial estates in the state. To fulfil the above mandate, the Corporation has established 202 industrial estate. Under the direction of Government of India, Department of Industrial Policy and Promotion (DIPP), State Government had taken initiative under the Ease of Doing Business (EODB) to provide select services online. Gujarat Industrial Development Corporation (GIDC) implemented a smart DCR system for plan approval. The software will study the engineering plans provide in the CAD format, Process the plans and generate complete and detailed set of report for further decisions by the approval authorities. A large amount of time saving will be achieved and the planners consider this as a boon to them. This also helps investors as the waiting time for sanctions/approvals will be greatly reduced.

2. PROMINENT PROCESS OF THE SOFTWARE 2.1 Online Building Plan Approval System Process:

Automation of Online Building Plan Approval System is the main part of the SmartDCR which is used by Architects as well as Officers of Gujarat Industrial Development Corporation. 1. System is designed for Architects to register and submit the drawing and get the

Reference Number of the Application. 2. This system is designed to allow an Architect to submit the drawing and check

the status of drawing online. 3. The software will facilitate communication between Architects via E-Mail, Public

can also view the status of their File Online. 4. The system also contains a relational database having list of Architects’ details. 5. The Architects can also get their scrutiny report online using their Reference

Number.

2.2 Smart DCR Scrutiny Process:

This Process will scrutinize the submitted drawing by comparing with Gujarat Bye-Laws and generates Reports. The uploaded drawing should be in .dwg format. Architects can check their drawing status, whether successfully submitted or Returned back through e-mail.

3. OBJECTIVES To bring transformation in the plan scrutiny processing system with speed, accuracy, consistency and transparency in the entire scrutiny process. To achieve the goal, it is proposed to automate the planning scrutiny process by customization with Smart DCR.

4. SCOPE OF THE SYSTEM

The Automation helps to increase the productivity and Accuracy of the Drawing Result. 6. Speed up the Scrutiny process.

Page 4: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 3 | 9

7. Easier Public Interaction with Online System. 8. Reduce the Time consumption and Manual Errors of Scrutiny Process. 9. Savings on the infrastructure required to store paper drawings. 10. Easy to retrieve data since the data is stored in digital format.

5. DO’s and DON’Ts: The processing of the file and further generation of reports is dependent on the Polylines, Lines and Text placed in the drawing file.

5.1 DO’s:

1. Floor plans, section, elevation to be kept in Scale 1:1 in meters 2. Polylines shall be drawn in the form of Light Weight Polylines (lwpolylines), as 3D

Polylines are not supported. They should be drawn as closed polylines. 3. Polyline’s line thickness shall be zero. 4. Drawing objects shall be placed in model space only. 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61

polyline

5.2 DON’T’s: 1. All drawing objects shall be in 2 Dimensional (Z-Coordinates – Zero) and placed

without any elevation. 2. Blocks, Regions, Wipe-out and External references shall not be placed in the drawing

as they will not be processed. 3. The Colour coded items, i.e. polylines, lines and texts which are intended to be

processed must be in the layers starting with FLOOR. Other layers will be ignored by the software

4. Mtext will not be processed by the software and whatever text placed on Floor layers shall be Text only.

5. Plans prepared using Educational version of AUTOCAD or other software like REVIT cannot be accepted as its use is limited.

6. DRAWING FILE SPECIFICATIONS

Preparation of computerized plans for SmartDCR has the following steps, which are to be followed compulsory. Otherwise SmartDCR will not process the given drawing.

1. Proposed Floor layer: FLOOR01, FLOOR02, etc. corresponding to the floor count.

2. FLOOR-STILT or FLOOR-GROUND for common Site related details.

3. For Proposed Basement floor, layer should be FLOOR-BF1, FLOOR–BF2 etc. Corresponding to the Basement Floor Count.

4. Don’t use unnecessary spaces in layer Names.

2. All proposal drawing should be in .DWG Format

3. All objects to be processed by SmartDCR should be drawn using Lines, Polylines and Text and placed in layers starting with Floor.

4. Layers and Colours should be followed as per the colour code table.

5. Remove the unused layers, dimension styles etc.

6. Drawing units should be in meters.

7. All details should be drawn in scale 1:1 (True Scale).

8. Avoid unnecessary objects in the drawing.

9. In the site plan, Front Setback should be in the Bottom Of the drawing.

10. Avoid unnecessary coordinates in polylines.

Page 5: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 4 | 9

11. Don’t Overlap the Objects.

7. PRE-CHECK SOFTWARE:

Pre-check is the software given for finding out all the polyline, line, and text related problems in the drawing. When the Applicant submits the building map proposal, this software enables the applicant to rectify the defects in the drawing and make it suitable to run in the Scrutiny software. It reads the drawing elements and lists all the discrepancies in the drawing. It will process the file and gives the output with various parameters as listed below. If errors are found in the drawing, the drawing will be populated with hyperlinks to the errors and will be returned to the Applicant via email.

1. Setback Boundary 2. Multiple Polyline Geometry Problems 3. Invalid object colour 4. Misplaced OTS 5. Existence of Blocks, Regions, Wipe-outs & External references in Floor layers 6. Mandatory requirements 7. Other critical errors

By clicking on the above disqualified items in the software interface, details will be displayed such as disqualified object name; floor name and drawing coordinate position. It will also draw a crossed grey line on all the disqualified objects throughout the drawing.

8. PROCEDURE TO CREATE A DRAWING

8.1 Parameters to be drawn using LINE Objects:

1. Gate

2. Basement Floor Height

3. Stilt Floor Height

4. Plinth Height

5. Floor Height

6. Front margin

8. Side 1 margin

9. Side 2 margin

10. Rear margin

11. Building height

12. Total building height

8.2 Parameters to be drawn using POLYLINE Objects:

1. Plot Boundary

2. Margin Boundary

3. Stilt Parking Area Boundary

4. Rain Water Harvesting Trench

5. FSI

6. Staircase Area

7. Lift

8. Balcony

9. Block Rectangles for Group Development

Page 6: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 5 | 9

10. Bounding Rectangle

11. Visitor parking

12. Reserved for Cars

13. Parking 8.3 Parameters to be drawn using TEXT Objects:

1. Usage of Commercial building such as Office, Restaurant, Departmental store,

Shop, Educational etc and Usage of Non habitation such as Water closet, Bathroom, Urinal

2. Tree text should be kept as TREES-1 or TREES-2 or TREES-3 etc. 3. Names of blocks, Typical Block text 4. Typical floor text:

In the Text Objects for Typical Floors are followed as

Format: “FLOOR01, FLOOR02, FLOOR03, FLOORnth

- Typical” In the Text Objects for Typical Blocks are followed as

Format: “BLOCK01, BLOCK02, BLOCK03…… BLOCKnth

- Typical”

Page 7: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 6 | 9

9a. DETAILS OF COLOUR CODE FORMAT:

S.No. Description Color Code

Corresponding Layer

Polyline Objects

1 Plot Boundary 7 FLOOR-STILT/FLOOR-GROUND

2 Margin Boundary 10 FLOOR-STILT/FLOOR-GROUND

3 Stilt Parking Area Boundary 5 FLOOR-STILT

4 Rain Water Harvesting Trench 42 FLOOR-STILT/FLOOR-GROUND

5 Residential FSI 181 Applicable floor layer*

6 Commercial FSI 6 Applicable floor layer*

7 Staircase Area 115 Applicable floor layer*

8 Lift 22 Applicable floor layer*

9 Balcony 35 Applicable floor layer*

10 OTS and Duct 3 Applicable floor layer*

11 Industrial FSI 134 Applicable floor layer*

12 Non FSI 4 Applicable floor layer*

13 Bounding Rectangle 61 FLOOR-STILT/FLOOR-GROUND

14 Visitor Parking 152 FLOOR-STILT/FLOOR-GROUND

15 Reserved for Cars 245 FLOOR-STILT/FLOOR-GROUND

16 Parking area 104 FLOOR-STILT/FLOOR-GROUND

Text Objects

1 Water closet, Bathroom, Urinal etc. 81 Applicable floor layer*

2 Block Naming and Typical Block text 50 FLOOR-STILT / FLOOR-GROUND

3 Floor Naming and Typical text for identifying Typical floors

7 Applicable floor layer*

4 No. of Trees to be planted inside the Plot 93 FLOOR-STILT/FLOOR-GROUND

5 Industrial building use Text 134 Applicable floor layer*

6 Non FSI 4 Applicable floor layer*

Line Objects

1 Floor height 91 Applicable floor layer*

2 Stilt Floor Height 21 FLOOR-STILT

3 Basement Floor Height 123 FLOOR-BF1

4 Plinth height 105 FLOOR-STILT/FLOOR-GROUND

5 Front margin 4 FLOOR-STILT/FLOOR-GROUND

6 Side1 margin 6 FLOOR-STILT/FLOOR-GROUND

7 Side2 margin 2 FLOOR-STILT/FLOOR-GROUND

8 Rear margin 3 FLOOR-STILT/FLOOR-GROUND

9 Gate 161 FLOOR-STILT/FLOOR-GROUND

Page 8: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 7 | 9

9b. LIST OF NON FSI TEXT

1. OUTHOUSE

2. GARAGE

3. WATER CLOSET

4. STORE SHED

5. PORCH

6. MOTOR QUARTERS

7. PRIVEYS

8. BATHROOM

9. COOLING TOWER

10. GENERATOR ROOM

11. TRANSFORMER ROOM

12. SECURITY CABIN

13. PUMP ROOM

14. WATER TANK

15. SERVANT QUARTERS

16. FOUNTAIN

17. SEPTIC TANK

18. SWIMMING POOL

19. OVER-HEAD TANK

20. WC

Page 9: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

GIDC Smart DCR – User Manual July 2017

P a g e 8 | 9

ANNEXURE PARAMETERS SNAPSHOTS

Page 10: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

S.No Description Layer

GIDC-Smart DCR-USER MANUAL

1 Super Imposed Plot Boundary shall be drawn as Polyline inColor No. 7

FLOOR-GROUNDorFLOOR-STILT

SUPER IMPOSED PLOT BOUNDARY

Color

Number

Super ImposedPlot Boundary

7

Polyline

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30SI

DE

OPE

NSP

AC

E

PATT

A20

.64

Page 11: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

2 Margin boundary shall be drawn as Polyline in Color No. 10 FLOOR-GROUNDorFLOOR-STILT

MARGIN BOUNDARY

Color

Number

Margin Boundary

10

Polyline

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30SI

DE

OPE

NSP

AC

E

PATT

A20

.64

Page 12: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

3 Front margin shall be drawn as Line in Color No. 4 FLOOR-GROUNDorFLOOR-STILT4 Side 1 margin shall be drawn as Line in Color No. 6

5 Side 2 margin shall be drawn as Line in Color No. 2

6 Rear margin shall be drawn as Line in Color No. 3

MARGIN

Color

Number

Rear Margin

3

Line

Color

Number

Side 2Margin

2

Line

Color

Number

Side 1Margin

6

Line

Color

Number

Front Margin

4

Line

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.30

1.94

1.30

3.89

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.20

SID

EO

PEN

SPA

CE

PATT

A20

.64

Page 13: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

7 Plot frontage / Width of site shall be drawn as Open Polylinein Color No. 96.

FLOOR-GROUNDorFLOOR-STILT

PLOT FRONTAGE / WIDTH OF SITE

Color

Number

Plot Frontage

96

Open Polyline

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30SI

DE

OPE

NSP

AC

E

PATT

A20

.64

Page 14: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

Color

Number

Visitor Parking

152

Polyline

RESERVED FOR CARS

STILT FLOOR PLAN

8 Visitor Parking area shall be drawn as Polyline in Color No.152. Parking area shall be drawn as Polyline in Color No. 104.Reserved for Cars parking area shall be drawn as Polyline inColor No. 245. Additionally Stilt Parking area shall be drawnas Polyline in Color No. 5.Note: Colour No. 5 is applicable only for Stilt Parking and notfor Open Parking.

FLOOR-STILT

COVERED PARKING

REAR OPEN

12 X 2.25FRONT OPEN

4.5M WIDE GATE

PARKING AREA

VISITOR PARKING Color

Number

Parking Area

104

Polyline

Color

Number

Reserved for Cars

245

Polyline

12.02

17.05

12 X 1.66

SID

EO

PEN

1.51

X13

.14

SID

EO

PEN

1.51

X13

.14

Color

Number

Stilt Parking

5

Polyline

Page 15: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

9 Visitor Parking area shall be drawn as Polyline in Color No.152. Parking area shall be drawn as Polyline in Color No. 104.Reserved for Cars Parking area shall be drawn as Polyline inColor No. 245

FLOOR-GROUND

OPEN PARKING

Color

Number

Visitor Parking

152

Polyline

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

2.40

2.04

2.40

6.71

PATTA 10.00

RESERVED FOR CARS

PATT

A20

.64

2.30SI

DE

OPE

NSP

AC

E

PATT

A20

.64

22 M WIDE ROAD

PARKING AREA

VISITOR PARKING

Color

Number

Parking Area

104

Polyline

Color

Number

Reserved for Cars

245

Polyline

Page 16: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

10 Rain Water Harvesting Trench shall be drawn as Polyline inColor No. 42.

FLOOR-GROUNDorFLOOR-STILT

RAIN WATER HARVESTING TRENCH

Color

Number

Rain WaterHarvesting Trench

42

Polyline

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30

SID

EO

PEN

SPA

CE PA

TTA

20.6

4

RAINWATER HARVESTING

Page 17: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

11 Residential FSI shall be drawn as Polyline in Color No. 181. Applicable FloorLayer

RESIDENTIAL FSI

Color

Number

Residential FSI

181

Polyline

BED ROOM

3.0 x 4.5

HALL/DINING

4.93 X 3.92

2.00 x 3.00

1.81 X 2.19

D1

D

O

FIRST FLOOR PLAN

A

D1

1.81 X 2.19

BATHROOM

WATER CLOSET

BATHROOM

W

V

V

W

W

W

9.75

11.70

KITCHEN

WATER CLOSET

Page 18: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

12 Dwelling unit shall be drawn as Polyline in Color No. 230 andKitchen text with Dwelling unit text shall be kept inside 230Color Polyline

Applicable FloorLayer

DWELLING UNIT

Color

Number

Dwelling Polyline

230

Polyline

BED ROOM3.0 x 4.5

HALL/DINING4.93 X 3.92

KITCHEN2.00 x 3.00

D1

D

O

FIRST FLOOR PLAN

KITCHEN

1

D1

W

V

V

W

W

W

Color

Number

Kitchen

230

Text

9.75

11.70

1.81 X 2.19

1.81 X 2.19

BATHROOM

WATER CLOSET

BATHROOM

WATER CLOSET

Color

Number

Dwelling unit Text

230

Text

Page 19: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

13 Bathroom, Water closet and Urinal shall be drawn as Polylinein Color No. 81 and text shall be placed

Applicable FloorLayer

BATHROOM, WATER CLOSET AND URINAL

FIRST FLOOR PLAN

Color

Number

Water closet

81

Polyline and Text

Color

Number

Bathroom

81

Polyline and Text

BED ROOM3.0 x 4.5

HALL/DINING4.93 X 3.92

KITCHEN2.00 x 3.00

D1

D

O

KITCHEN

1

D1

W

V

V

W

W

W

9.75

11.70

1.81 X 2.19

1.81 X 2.19

BATHROOM

WATER CLOSET

BATHROOM

WATER CLOSET

Page 20: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

14 Habitation room shall be drawn as Polyline in Color No. 150 Applicable FloorLayer

HABITATION ROOM

Color

Number

Habitation room

150

Polyline

BED ROOM

3.0 x 4.5

HALL/DINING

4.93 X 3.92

2.00 x 3.00D1

D

O

FIRST FLOOR PLAN

KITCHEN

1

D1

W

V

V

W

W

W

9.75

11.70

1.81 X 2.19

1.81 X 2.19

BATHROOM

WATER CLOSET

BATHROOM

WATER CLOSET

Page 21: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

15 Commercial FSI shall be drawn as Polyline in Color No. 6 andcorresponding Building use text should be kept inside theboundary in Color No. 6.

Applicable FloorLayer

COMMERCIAL FSI

FIRST FLOOR PLAN

Color

Number

Commercial FSI

6

Polyline and Text

W W

F.E

F.E

F.E

F.G1 F.G

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W W

F.G2

ALL COLUMN0.3MX0.6M

16.61M x 32.92M

V1

UP LIFT1.98X1.98

L.D

TOILET1.98X1.98

V1

D1

O

SHOP

7.46

14.58

Page 22: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

16 Industrial FSI shall be drawn as Polyline in Color No. 134 andtext shall be placed in the same Color

Applicable Floorlayer

INDUSTRIAL FSI

Color

Number

Industrial FSI

134

Polyline and Text

GROUND FLOOR PLAN

MD

W2

W2

6.72 M X 8.23 M

6.72M X 6.30M

W2

W5

W3

W3W5

BOILER HOUSE

HEIGHT-8.00W2

MD

7.02

BAGAS STORAGE AREA

HEIGHT-4.00

W5

W2

W1

16.63

Page 23: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

LIFT2.24 x 2.40

UP

W

17 Non FSI area shall be drawn as Polyline in Color No.4 andText shall be placed in the same layer. Kindly refer to section9b in User Manual for Non FSI text.

Applicable FloorLayer

D

Color

Number

Pump Room

4

Polyline and Text

NON FSI

1.74 X 2.69

PUMP ROOM

BASEMENT FLOOR PLAN

7.71

16.87

Page 24: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

18 Building blocks shall be distinguished from each other in caseof Group Developments. Distinguishing of blocks shall bedrawn by Polylines in Color No. 50 along with Block names astext in the same Color for identifying individual blocks presentsuch as Block-A, Block-B. The individual floor plans shall bedrawn completely within Color No. 50 Polyline. In Site plan,Block footprint polyline shall be drawn in Color No. 10 andBlock name text shall be kept in Color No. 50 for each block

FLOOR-GROUNDorFLOOR-STILT

DISTINGUISHING BLOCKS

Color

Number

Block Distinguishers

50

Polyline & Text

NPLOT PLAN FOR G.I.D.C. APPROVAL

300MM DIA, CASING

160MM DIA. PIPE

MAI

NEN

TRY COP-1

COP-2

P-1

P-2

P-3

N

B

B

A X 1TOTAL (I)

A 9.00 X 10 .00 X 0.5

TOTAL (II)

TOTAL

A

N

2

34

A

A

A

B

B

B

B

B

B

PLANT BUILDINGOFFICE BLDG. ST ORAGE S HED

A

A A

A

A X 1

B X 1TOTAL (I)

A 1 8.50 X 1 5.00 X 0 .5

TO TAL (II)

TO TAL

A X 1B X 1

TOTAL (I)

A 1 6.50 X 1 8.00 X 0 .5TOTAL (II)

TO TAL

A X 1TO TAL (I)

A X 1TOTAL (I)

A X 1

TOTAL (I)

A X 1TOTAL (I)

234

AA

A X 1TO TAL (I)

BLOCK 2 3 4 BLOCK 6

BLOCK 2 3 4

BLOCK 7 8TREES-80

BLOCK 6

BLOCK 5

BLO CK 1

Color

Number

Block Footprint

10

Polyline

Color

Number

Block Name

50

Text

Page 25: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

TYPICAL FLOOR TEXT

FLOOR01,FLOOR02,FLOOR03-TYPICAL

19 For the Typical floors, if it starts from FLOOR01 and lasts upto FLOOR03, the text shall be given in the Colour No. 7 as"FLOOR01, FLOOR02, FLOOR03-TYPICAL", as shown inthe drawing below.

Starting FloorName(FLOOR01)

Color

Number

Typical Floor

7

Text

TYPICAL FLOOR PLAN(First, Second and Third floor )

D1

D1

D2

W3 W4

BED ROOM3.40 x 3.80

BED ROOM3.34 x 2.91

HALL2.82 x 3.92

1.88 x 2.78KITCHEN

W6

W5

W7

W6

1

Typical Floor

Polylines

LayerFLOOR01

Page 26: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

20 Height of the building shall be drawn as Line in Color No. 151 FLOOR-GROUNDorFLOOR-STILT

HALL

KITCHEN

KITCHEN

HALL

HALL

SECTION AT AA'

HEIGHT OF THE BUILDING

Color

Number

Height ofthe building

151

Line

KITCHEN

GL GL

12.55

Page 27: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

21 Total Height of the building shall be drawn as Line in ColorNo. 233

FLOOR-GROUNDorFLOOR-STILT

TOTAL HEIGHT OF THE BUILDING

Color

Number

Total height ofthe building

233

Line

HALL

KITCHEN

KITCHEN

HALL

HALL

SECTION AT AA'

KITCHEN

GL GL

17.13

Page 28: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

22 Stilt Floor height is the minimum clear height taken from thebottom of the stilt floor to the bottom of the roof beam. It shallbe drawn as line in Color No. 21.

FLOOR-STILT

First floor

Stilt Parking

STILT FLOOR HEIGHT

Color

Number

Stilt Height

21

Line

Parapet

Stilt Parking3.98

10.39

11.96

GL GL

SECTION AT AA'

Page 29: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

23 Basement Floor height is the distance measured between thebottom of the basement floor and roof of the same basementfloor level. It shall be given as line in Color No. 123. If there ismore than one basement floor, its height shall be given in thecorresponding basement floor layer.

FLOOR-BFxwhere 'x' is thebasement floornumber.

BASEMENT FLOOR HEIGHT

Color

Number

Basement FloorHeight

123

Line

Ground Floor

Basement Parking

Parapetl

GL GL

4.28

5.19

6.77

SECTION AT AA'

Page 30: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

Color

Number

Plinth Height

105

Line

SECTION B-B

24 Plinth height shall be drawn as line in Color No. 105 FLOOR-GROUNDorFLOOR-STILT

PLINTH HEIGHT

9.69

12.68

G.L G.L0.59

BED ROOMHALL TOILET

BED ROOMHALL TOILET

Page 31: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

SECTION B-B

25 Floor height shall be drawn as line in Color No. 91 In all the floors,wherever applicable

FLOOR HEIGHT

Color

Number

Floor Height

91

Line

9.69

12.68

G.L G.L0.59

BED ROOMHALL TOILET

BED ROOMHALL TOILET

Page 32: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

GATE

26 Gate shall be drawn as line in Color No. 161 FLOOR-GROUNDorFLOOR-STILT

Color

Number

Gate

161

Line

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

4M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M.ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30

SID

EO

PEN

SPA

CE

PATT

A20

.64

Page 33: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USERMANUAL

LIFT AND STAIRCASE

UP

UP

Color

Number

Staircase

115

Polyline

Color

Number

Lift

22

Polyline

27 Lift shall be drawn as Polyline in Color No. 22. Staircase shallbe drawn as Polyline in Color No.115.

Applicable FloorLayer

Page 34: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USERMANUAL

Color

Number

Open to Skyand Duct

3

Polyline

28 Open to sky and duct shall be drawn as Polyline in Color No.3.

FLOOR-GROUNDorCorrespondingFloor Layer

BED ROOM

3.0 x 4.5

HALL/DINING

4.93 X 3.92

KITCHEN

2.00 x 3.00

1.81 X 2.19

MD

D1

D

O

GROUND FLOOR PLAN

1

WATER CLOSET

W

V

W

W

W

Open to sky1.81 x 1.19

OPEN TO SKY AND DUCT

9.75

11.70

KITCHEN

1

WATER CLOSET

Page 35: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

29 Tree text to be kept in Color No. 93 FLOOR-GROUNDorFLOOR-STILT

TREE

TREES-2

Color

Number

Tree

93

Text

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.68

2.53

1.68

5.05

PATTA 10.00

22 M.ROAD

PATT

A20

.64

1.56

SID

EO

PEN

SPA

CE

PATT

A20

.64

Page 36: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

MAI

NE

NTR

Y

COP-1

COP-2

15.16 x 14.41 = 218.45 SQ.M.PARKING AREA

P-1

P-2

P-3

30 COMMON OPEN PLOT area shall be drawn as Polyline inColor No. 36

FLOOR-GROUNDorFLOOR-STILT

COMMON OPEN PLOT

SITE PLAN

Color

Number

Common Open Plot

36

Polyline

Page 37: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

BALCONY

Color

Number

Balcony

35

Polyline

31 Balcony shall be drawn as Polyline in Color No. 35 Applicable FloorLayer

1M WIDE BALCONY

W3

V

W4 W3

D

D

D

WATER CLOSET

KITCHEN

BED ROOM

BED ROOM

DRG./DIN.

D1W3

W3

D23.0 x 1.62

2.91 x 2.11

3.11 x 3.40

3.05 x 4.57

3.41 x 5.37

FIRST FLOOR PLAN

13.13

11.70

1

KITCHEN

1

1M WIDE BALCONY

Page 38: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

32 Road width shall be drawn as line in Color No. 41 FLOOR-GROUNDorFLOOR-STILT

ROAD WIDTH

Color

Number

Road width

41

Line

FRONT OPENSPACE

REAR OPENSPACE

PROPOSED BUILDING

SITE PLAN

3M WIDE GATE

SID

EO

PEN

SPA

CE

RWHRWH

1.40

2.11

1.40

4.21

PATTA 10.00

22 M WIDE ROAD

CAR PARK

25 SQ.M

PATT

A20

.64

1.30SI

DE

OPE

NSP

AC

E

PATT

A20

.64

Page 39: Smart DCR GIDC - User Manual · 5. Site plan, floor plan, section, elevation to be kept inside bounding rectangle color 61 polyline 5.2 DON’T’s: 1. All drawing objects shall be

Smart DCR Version 2

S.No Description Layer

GIDC-Vinzas-Smart DCR-USER MANUAL

33 Bounding rectangle shall be drawn as polyline in Color No 61.Entire drawing should be kept inside the Boundingrectangle.If there are any objects found outside Boundingrectangle, drawing will be marked as error by the Prechecksoftware.

FLOOR-GROUNDorFLOOR-STILT

Color

Number

BOUNDING RECTANGLE

61

Polyline

BOUNDING RECTANGLE

The lower left corner of the Bounding rectangle to be kept in 0,0,0 co-ordinate