simatic wincc v12 engineering for all hmi- · pdf filepage 1 2012-10-29 visualization with...
TRANSCRIPT
1
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 1 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Engineering for all HMI-Systems
Single Station… based on WinCC flexible RT
SCADA System… based on WinCC V7 Runtime
Engi
neer
ing
Editi
on
Basic Panels Comfort Panels,Mobile Panels
SCADAPanel PC, Standard PC
Pane
l
WinCC Basic
WinCC Comfort
WinCC Professional 512, 4k, max. PowerTags
WinCC Advanced
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 2 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Supported hardware
SIMATIC HMI Basic PanelsKP300 BasicKP400 Basic KTP 400 Basic,KTP 600 Basic,KTP 1000 Basic, TP 1500 Basic
SIMATIC HMI Panels / Multi PanelsOP73, OP77, TP177, OP177,TP277, OP277,MP177, MP277, MP377SIMATIC HMI Mobile PanelsMobile Panel 177, Mobile Panel 277Mobile Panel 277 IWLAN V2SIMATIC HMI Comfort PanelsKTP 400 Comfort, KP 400 Comfort,TP 700 Comfort, KP 700 Comfort,TP 900 Comfort, KP 900 ComfortTP 1200 Comfort, KP1200 ComfortTP 1500 Comfort, KP1500 ComfortTP 1900 Comfort, TP2200 Comfort
Win
CC
Com
fort
Win
CC
Bas
ic
Win
CC
Adv
ance
d
Win
CC
Pro
fess
iona
l
New
New
2
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 3 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Supported hardware
SIMATIC WinCC Runtime Professional (PC-based SCADA)…with 128, 512, 2k, 4k, 8k, 64k PowerTagsIPC427C/D, IPC477C/D (Client)IPC577C (Client)IPC627C, IPC827CIPC677CIPC647C, IPC847CIPC547C/DStandard PC
SIMATIC WinCC Runtime Advanced (PC-based single station)…with 128, 512, 2k, 4k PowerTagsIPC227D, IPC277DIPC427C/D, IPC477C/DIPC577CIPC627C, IPC827CIPC677CIPC647C, IPC847CIPC547D Standard PC
Win
CC
Pro
fess
iona
l
Win
CC
Adv
ance
d
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 4 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Comfort Panels – Overview
4''W 7''W 9''W 12''W 15''W 19''W 22''W
Display size 4,3'' 7,0'' 9,0'' 12,1'' 15,4'' 18,5'' 21,5''
Resolution 480x272 800x480 1280x800 1366x768 1920x1080
Prozessor ARM 532 MHz x86 500 MHz x86 1GHz
Project memory 4 MB 12 MB 24 MB
Tags 1024 2048 4096
Messages 2000 4000 6000
Recipes 100 / 200 / 200 * 300/ 500 / 1000 * 500 / 1000 / 2000
Images 500 500 750
Archives 10 / 10.000 ** 50 / 50.000 **
Scripts 50 100 200
Viewer / multimedia Internet Explorer, PDF, Word- and Excelviewer, Multimedia Player
Sm@rtServer yes
*) recipes / data sets per recipe / entries per data set **) Archive / entries per archive
New New New
3
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 5 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12Industrial Thin Client – SIMATIC ITC
New
SIMATIC ITC ITC1200 ITC1500 ITC1900 ITC220012" Touch
Widescreen15" Touch
Widescreen19” Touch Widescreen
22" TouchWidescreen
Resolution 1280 x 800 1280 x 800 1366x768 1920 x 1080
Display high resolution, 16 Mio. colors, 100% dimmable
CPU Intel Celeron 1,2 GHz
Interfaces 1 x GBit LAN , 2 x USB 2.0 (backside)
Webbrowser HTML5, XML, CSS, JavaScript
Protocols Sm@rtServer, RDP, VNC
Active connections 5
Power supply 24V DC
Certificates CE, cULus, C-Tick, ATEX Zone 2/22 (planned)
Produkt link: 60521782 FAQ: 63258317 Produktvideo
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 6 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 1 – Compatibility mode
TIA Portal V12 support for the Service use case Exception: Compile of Runtime Professional V11
Upgrade
RT V11SP2
Panel / SCADA 1
RTV12
Panel / SCADA 2
WinCC ES V11 SP2
RT V11SP2
V11Proj.
WinCC ES V12 (compatibility mode)
RT V11SP2
V12Proj.
WinCC ES V12
RT V11SP2
RTV12
4
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 7 2012-10-29 Visualization with WinCC V12
V11Proj.
SIMATIC WinCC V12 1 – Compatibility mode
Work on V11 projects with V12 V11 project can be modified with different versions of the engineering system Saved projects can be opened with TIA Portal V11 SP2 again Functionality and features of TIA Portal V11 SP2 products are supported
Open project supported
Edit/compile/downloaddevices supported*
WinCC V11SP2
Engi
neer
ing
syst
em WinCC V12(V11 compatibility mode)
Engi
neer
ing
syst
em *Compile and download not supported for Runtime Professional V11
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 8 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
WinCC ES V12
RTV12
SIMATIC WinCC V12 2 – Upgrade to V12
Upgrade
RT V11SP2
Panel / SCADA 1
RTV12
Panel / SCADA 2
WinCC ES V11 SP2
RT V11SP2
V11Proj.
WinCC ES V12 (compatibility mode)
RT V11SP2
V12Proj.
RT V11SP2
Use of new functionality coming with WinCC V12 Exception: Compile As Runtime Professional V11
5
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 9 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
V11Proj.
SIMATIC WinCC V12 2 - Upgrade to V12
Use of new functionality coming with WinCC V12 Use of new functions (e.g. S7-1500) V11 project must be upgraded to V12 Project upgrade includes upgrade of RT Professional Panels and RT Advanced remain in version 11 for service use cases
Save (V12) project supportedEdit/compile/download devices supported
WinCC V12
Engi
neer
ing
syst
emUpgraded V11 project or newlycreated V12 project can only be opened with TIA Portal V12 products
V12Proj.
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 10 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 2 – How to…
Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named “..._V12” No downgrade afterwards, no more use in TIA Portal V11
1
23
Upgrade to V12
6
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 11 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Create, modify and compile V11 devices in V12 project Exception: Compile As Runtime Professional V11
WinCC ES V12
RTV12
SIMATIC WinCC V12 3 – V11 devices in TIA Portal V12
Upgrade
RTV11
Panel / SCADA 1
RTV12
Panel / SCADA 2
WinCC ES V11 SP2
RT V11SP2
V11Proj.
WinCC ES V12 (compatibility mode)
RT V11SP2
V12Proj.
RT V11SP2
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 12 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 3 – V11 devices in TIA Portal V12
No upgrade of Panels FW forced by new version of engineering system WinCC V12 can configure devices with RT versions V11 and V12 Configured RT version decides about supported functionality in editors Version change (V11↔V12) is handled similar to Device type change
WinCC V12
Engi
neer
ing
syst
em Compile and download not supported for Runtime Professional V11
V11 device
V12 deviceV12Proj.
7
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 13 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Upgrade process
Upgrade V11 projects to V12 V11 project file remains available V12 project build in a new folder named “..._V12” No downgrade afterwards, no more use in TIA Portal V11
1
23
Upgrade to V12
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 14 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 V11 devices in TIA Portal V12
No upgrade of Panels FW forced by new version of engineering system WinCC V12 can configure devices with RT versions V11 and V12 Configured RT version decides about supported functionality in editors Version change (V11↔V12) is handled similar to Device type change
WinCC V12
Engi
neer
ing
syst
em Compile and download not supported for Runtime Professional V11
V11 device
V12 deviceV12Proj.
8
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 15 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12 Select RT version
Configurable RT version in “Add new device” dialog
ConfigurableRT version in Hardware catalog
Configured RT version in Catalog information of configured device(Editor Devices & networks)
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 16 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12 Change RT version
Change device type / version for selected device
9
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 17 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Communication drivers
WinCC Basic offers drivers for:SIMATIC S7-1500SIMATIC S7-1200SIMATIC S7-300/400SIMATIC S7-200LOGO!Allen-Bradley DF1, EtherNet/IP Mitsubishi MC TCP/IPModicon Modbus TCP/IP
No support for SIMATIC S5
New
New
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 18 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
* SINUMERIK Integrate Create MyHMI / WinCCoption has to be installed
SIMATIC WinCC V12Communication drivers
WinCC Comfort / Advanced offers drivers for:SIMATIC S7-1500SIMATIC S7-1200SIMATIC S7-300/400SIMATIC S7-200LOGO!Allen-Bradley DF1, EtherNet/IP Mitsubishi FX, MC TCP/IPModicon Modbus RTU, TCP/IPOmron Host Link
OPC (DA, XML DA, UA)
No support for SIMATIC S5
Communication driver
New
New
10
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 19 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Communication driver for LOGO!Communication interface EthernetAvailable in HMI devices Basic PN Panels Mobile Panels 177PN, 277 Multi Panels Comfort Panels Runtime Advanced
Data Type and address range
SIMATIC WinCC V12 Process Communication DriverWhat’s new: LOGO!
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 20 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Communication drivers
WinCC Professional offers drivers for:SIMATIC S7-1500SIMATIC S7-1200SIMATIC S7-300/400Allen-Bradley EtherNet/IP Mitsubishi MC TCP/IPModicon Modbus TCP/IP
OPC (DA / XML DA)
No support for SIMATIC S5Communication driver
New
11
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 21 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Diagnostic services
STEP 7 HMI WebServer CPU-Display
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 22 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Diagnostic services – Display at Panels / RT Advanced
System diagnostics viewer Displays the overview of accessible devices and the system state of the plant Switch between device and detail view Same concept at Comfort Panels, RT Advanced, CPU display and CPU webserver There is also a buffer viewer available for Basic Panels
12
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 23 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Diagnostic services – Display at Panels / RT Advanced
System diagnostics viewer – detect errors in plant Click forward through structure to find out the source of an error Autofocus on faulty device
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 24 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12New service concept
New panel service concept - Basic Panels
Runtime project stored on S7-1500 In the case of a device replacement the
HMI backup can be uploaded from the PLC directly into the new panel
Restore
Backup
PLCHMI
HMIUsual way
New
Basic Panels
13
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 25 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12How to…
Backup & restore via Basic Panel New item “Service & Commission” available Select “Backup” or “Restore” Scan for an accessible device or insert IP & connect afterwards Create a backup or select & restore an existing one Backup will be placed at or restored from PLCs SIMATIC memory card
Basic Panels
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 26 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware New panel service concept - Comfort Panels
Image transfer via USB-Stick or SD-Card (FAT32)Replacement of Comfort Panel without engineering system
possibleTIA Portal / ProSave is still possible
SIMATIC WinCC V12New service concept Comfort Panels
14
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 27 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Create a HMI OS image
SIMATIC WinCC V12How to… Comfort Panels
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 28 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Create a HMI OS image Select destination device & create
HMI OS image on memory card Choose matching display
if necessary adapt restore settings It is also possible to download
various images on device
SIMATIC WinCC V12How to…
2
Comfort Panels
1
15
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 29 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
1
Update OS from SD card or USB stick
SIMATIC WinCC V12How to… Comfort Panels
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 30 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
1
Update OS from SD card or USB stick
SIMATIC WinCC V12How to…
2
Comfort Panels
16
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 31 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
1
Update OS from SD card or USB stick
SIMATIC WinCC V12How to…
2
3
Comfort Panels
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 32 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
1
Update OS from SD card or USB stick
SIMATIC WinCC V12How to…
2
3
4
Comfort Panels
17
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 33 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Integrated connections
Addressing with integrated connections Absolute addressing: connected to address, tag name not necessary searches automatically (reconnect to PLC) for tag name
Symbolic addressing: connected to symbolic name, no relation to absolute address supported by S7-1200 and S7-1500 PLCs
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 34 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Integrated connections
NO absolute address in this access mode
Addressing PLC tags symbolically Insert tags from standard DBs, optimized DBs or tag tables
18
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 35 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Integrated connections
Default settings for addressing PLC tags Change default access method in TIA Portal settings Defines whether PLC tags are automatically addressed absolutely or symbolically Access method can also be changed by hand afterwards
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 36 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Use cases – Benefits of symbolic addressing:PLC: changes
SIMATIC WinCC V12Integrated connections
HMI: not necessary
Change address & PLC
Add a row above & PLC
PLC tags:
DB (standard or optimized) elements:
19
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 37 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Use cases – Benefits of symbolic addressing:PLC: changes
SIMATIC WinCC V12Integrated connections
Change name & PLC
HMI: not necessary
Name of PLC tags:
Tag is updatedautomatically
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 38 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Data types
Support of 64-bit data types in HMI Communication with S7-1200 or S7-1500 64-bit tags Higher resolution with usage of LREAL data types
Real Floating-point number 32-bit IEEE 754 +-3.402823e+38LReal Floating-point number 64-bit IEEE 754 +-1.79769313486231e+308
20
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 39 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
HMI tag table: browse PLC tagPLC tag table
SIMATIC WinCC V12 PLC tags restrictions
Restricted access to PLC tags Visible in HMI:
Shows whether the tag is visible by default Accessible from HMI:
Shows whether HMI can access this tag
even copy & paste does not insert those tags into tag tables
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 40 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
HMI tag table: browse PLC tagPLC tag table
SIMATIC WinCC V12 PLC tags restrictions
Restricted access to PLC tags Visible in HMI:
Shows whether the tag is visible by default Accessible from HMI:
Shows whether HMI can access this tag
even copy & paste does not insert those tags into tag tables
21
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 41 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12PLC tags restrictions
Drag & Drop structured PLC tags to HMI Each element is implemented as an individual HMI tag (not structured) HMI tag automatically connected to PLC tag Existing HMI connection is used or a new one will be created
Only tags with accessible flag are copied
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 42 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12PLC tags restrictions
Drag & Drop structured PLC tags to HMI Copy also of complex structures & paste as single tags in HMI tag table Only accessible elements are copied even if the flag is set “deep” in the structure
22
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 43 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 HMI protection levels
PLC and HMI protection levels S7-1500 PLC Protection level 4 affects all HMI devices Access granted with password from level 1, 2 or 3 Password defined at the HMI connection Basic Panels, Mobile Panel 277, Multi Panels x77, Comfort Panel, RT
Advanced & Professional support access via password
Only in this level a password is needed
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 44 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12How to…
PLC and HMI protection levels Password is needed in case of protection level 4
Set password to grant access to PLC
1
2
23
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 45 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
RT
SIMATIC WinCC V12 HMI protection levels
HMI
No password
S7-1500
Level 4
HMI
Level 1-3 password
S7-1500
Level 4
HMI
No password
S7-1500
Level 1-3
HMI
wrongpassword
S7-1500
Level 1-4
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 46 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Screens – Overview
Adjust zoom
New icons
Object type displayed behind
name
New tab
24
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 47 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Languages & multilingual texts
Easier handling of multilingual texts Edit texts of screen, whole groups or multi selections Copy and paste of texts All in one window without changing editing language Languages have to be activated in languages & resources
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 48 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Rewiring
Change object references similar to rewiring functionality from WinCC flexible Shows tag references within screens Finds tags with properties or events as point of use
25
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 49 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12How to…
LibraryScreen template
I/O field
Screen_1DB1_statusDB1_minDB1_max
Screen_2DB1_statusDB1_minDB1_max
Screen_2DB2_statusDB2_minDB2_max
Use cases: Same screens for different DBs
Copy screen
Screen_1DB1_statusDB1_minDB1_max
Connect tags
Change object reference
Find & replace string DB1 by DB2
rewire
Configuration
rewire
DB1 DB2
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 50 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12How to…
Change object references … Precondition: well organized tags Open from context menu Find and replace parts of tag names
12 3
4
26
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 51 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware Reconnect PLC tags similar to WinCC flexible based on: Symbolic addresses Absolute addresses
SIMATIC WinCC V12Reconnect PLC tags
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 52 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12Reconnect PLC tags
The path of the PLC tag matches
The connection has to be already created
Reconnect if the path / tag name matchesThe connection is marked red because… …PLC connection changed Reconnect checks validation in new connection path
…PLC connection changed & address changed Reconnect checks validation in new connection path &
updates the address
27
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 53 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12Reconnect PLC tags
The address of the PLC tag matches
The connection has to be already created
Reconnect if the address matchesThe field “PLC tag” is empty because... …tags have been imported …a copied tag table from library Reconnect finds matching tag names
The connection is marked red because… …PLC connection changed Reconnect checks validation in new connection path
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 54 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Runtime file browser
Runtime file browser Useful to transfer a file’s path to a tag by selecting the file in the browser The tag can be used to open webpages, PDFs, etc. Available for Comfort Panels and Runtime Advanced
28
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 55 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12How to…
Configuration Use new system function “OpenFileBrowser”, e.g. click event at a button Use “Initial directory” for browsing location Select a tag (Wstring) to configure the output path: Path (Out)
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 56 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Offline download
Download to device New: Download single stations to a local path
or an external device Usual way: Download to network path
RT
WinCC ClientEngineering Station
29
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 57 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Run as service
WinCC as service: WinCC servers as service, Clients interactively WinCC server is located in a separate room, no user needs to be logged in WinCC Runtime starts automatically with Windows Monitoring and control of the WinCC project from the clients / Web clients Dedicated Web Navigator or Data Monitor server as service
separated room
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 58 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12How to…
Configuration Open WinCC RT Start Select a project Switch to tab Operation mode Insert Windows user and password
Activate service
30
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 59 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Vertical fonts
Vertical fonts Define a font in vertical reading direction “@” in front of the name signals a vertical font Set text orientation vertical
1 2
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 60 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 PLC & HMI Engineer working together
Slides will be available for S7-300, S7-1200 & S7-1500 Slides are currently in work Published as newsletter (HMI- and TIA- Promotors) Published as FAQ
31
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 61 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12Comfort Panel migration
Integrated Classic project availableSwitch to STEP 7 and WinCC V11
WinCC (TIA Portal)
STEP 7 (TIA Portal)
Migration of project Device change Use of TIA Portal
Benefits
WinCCflexible
STEP 7classic
Integrated Classic project availableSwitch to WinCC V11
WinCC (TIA Portal)
Deintegration Migration of WinCC
flexible Device change
STEP 7classic
STEP 7classic
WinCCflexible
New projectUse of STEP 7 and WinCC V11
WinCC (TIA Portal)
STEP 7 (TIA Portal)
Use of TIA Portal Benefits
New projectUse of STEP 7 classic and WinCC V11
WinCC (TIA Portal)
Export of STEP 7 Tags Convert tags with TagConverter Import in WinCC V11
STEP 7classic
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 62 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Working with STEP 7 classic & WinCC V12 together
WinCC (TIA Portal) and STEP 7 classicExisting STEP 7 with new WinCC (TIA Portal) project
1. Create the HMI in WinCC (TIA Portal)2. Export the needed tags from STEP 73. Convert the export file with WinCC Tag Converter (Link)4. Import the converted file in WinCC (TIA Portal)
All tags are converted with absolute address Changes on some single tags in STEP 7 project can be updated manually „big changes“ can be updated with the help of Tag Converter
No support of reporting system errors (RSE) & controller alarms
32
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 63 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Export of tags from STEP 7 classicSingle data blocks Open the data block File Print „Generic / Text only“ printer Input path \ filename.txt in the following dialog
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 64 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Export of tags from STEP 7 classicSingle or several data blocks „Generic / Text only“ printer is the windows standard printer Right mouse on the needed data blocks Print Object Content Input path \ filename.txt in the following dialog for each DB
33
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 65 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Export of tags from STEP 7 classicSymbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 66 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Export of tags from STEP 7 classicSymbol table Open symbol table Symbol Table export Input path \ filename.asc in the following dialog
34
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 67 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Conversion of tags with WinCC Tag Converter Converts the tag export files of SIMATIC Manager, Rockwell (Allen-Bradley)
and Schneider/Modicon in the import-format of WinCC (TIA Portal)
WinCC Tag Converter
export file fromPLC programming Tool
converted file ready to import in WinCC
Industry Online Support:Deutsch English
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 68 2012-10-29 Visualization with WinCC V12
SIMATIC WinCC V12WinCC Tag Converter – How to…
Import of tags to WinCC (TIA Portal) The converted file with the tags can easily be imported.
Hint: the PLC connection should be created in WinCC previously
start tag import
HMI Tags Show all tags:Converted file:
35
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 69 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Advanced color picker Not every color is supported by each Panel Therefore TIA Portal adapts colors & displays the
current, the selected and the adapted color in a preview
Selected color
Adapted color, details see tooltip
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 70 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Cross references Number of locations where the object is used
1
2
36
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 71 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Move object to the next snap line Use “s” + “arrow key” to move object
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 72 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
New system function in SCADA Set language directly or toggle
37
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 73 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Events with improved look and feel
V11 V12
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 74 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Two new expression templates Expressions AND & OR added Additional space for expressions
Enough space for long expression
38
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 75 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Usability
Animate property: Support of floating points (range type) Including new elements: Brackets & intervals
Bracket Example If the process value (x) is … …than color is …[…-…] [0 - 0.25] 0 ≤ x ≤ 0.25 black]…-…] ]0.25 - 0.5] 0.25 < x ≤ 0.50 red]…-…[ ]0.5 - 1[ 0.5 < x < 1 yellow
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 76 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12 Usability
Support of floating points Use case expression: calculations Overlapping areas are invalid and marked red
RT V12
39
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 77 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Screen window Improved handling Select “Open screen” to switch to displayed screen
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 78 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Usability
Faceplates Blue bold colored text indicates the usage of a property
40
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 79 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Overview
Feature Panels RT Advanced RT ProfessionalHardware news - - -S7-1500 driverSymbolic addressing64-bit data typesRestricted access to PLC tagsProtection levelsNew tab for multilingual languagesChange object reference (rewire)Reconnect tagsOffline transfer - -Run as service - -
For internal use only / © Siemens AG 2012. All Rights Reserved.I IA AS S SUP FAPage 80 2012-10-29 Visualization with WinCC V12
Overview
Usability
PLC & HMI
SCADA
Screens
Tag management
Maintenance
Communication
Release Management
Hardware
SIMATIC WinCC V12Overview
Feature Panels RT Advanced RT ProfessionalSystem diagnostic viewer -Backup & restore an image at PLC only Basic - -OS Update via external devices only Comfort - -Advanced color picker - -Counting in cross referencesMove object to snap lines via keyboardAdvanced context menu for eventsNew expression templates - -Floating points for property animation - -Vertical fonts - -Improved handling of screen windows - -Faceplates: colored texts - -