sikafixkit pds

2
SikaFix ® Kit Construction Product Data Sheet Edition 06.2011/v2 SikaFix ® Kit SikaFix ® Kit Injection Repair Kit for Leaking Foundations Description The SikaFix ® Kit is an injection package for the repair of leaking cracks, static joints and voids, such as those in foundations. The kit includes a two-part polyurethane grout which expands in the presence of moisture to form a tough, flexible foam that firmly bonds to surfaces and seals against water. Where to Use The SikaFix ® Kit permanently stops the flow of unwanted water penetrating into or through: ■ Foundation and basement walls. ■ Cracked or honey combed concrete. ■ Concrete and masonry surfaces. ■ Pipe and utilities intrusions. ■ Wastewater or septic tanks. Advantages ■ Economical and easy to apply. ■ Complete kit supplied, no other materials needed. ■ Does not require specialized equipment. ■ Hydrophobic - only a small amount of water is needed for reaction. ■ Lasting adhesion to wet and dry surfaces. ■ Zero shrinkage maintains water tightness. ■ Permanently flexible and tough seal. ■ Environmentally friendly; cured product is inert. Technical Data Packaging Kit includes: 250 mL (8.45 US fl. oz) cartridge of SikaFix ® PU polyurethane grout 1 kg (2.2 lb) bag of Sikaset ® Plug quick-set mortar 20 Sika ® Injection 'T' ports with plugs Instruction Sheet and DVD Colour Mortar: Concrete Grey Grout: Light Amber Yield 2 cracks measuring 2.4 m (8 ft) long x 200 mm (8 in) deep x 3 mm (1/8 in) wide. Shelf Life 12 months in original, unopened packaging. Store between 10 - 32°C (50 - 90°F) in a dry place. Protect from freezing. If frozen discard. Properties at 23°C (73°F) and 50% R.H. (SikaFix ® PU) Open Time Approx. 5 hours, providing no moisture enters the cartridge. Shrinkage ASTM D1623 0% Elongation 25% Water Absorption 0.19 kg/m 2 How to Use Surface Preparation For cracks, joints or voids less than 6 mm (1/4 in) wide, create a ‘V’ notch at least 6 mm (1/4 in) wide and 13 mm (1/2 in) deep using an angle grinder, disc cutter or sharp, hand chipping tool. Clean all cracks well with a wire brush to remove all dust, laitance (thin cement film), curing compounds, loose, friable and foreign particles, grease and any material which would obstruct bond of mortar and penetration of grout. Substrates should be clean and sound and moisture must be present to bond the mortar and activate the grout. Application Fixing of Sika ® Injection ' T's - Starting from bottom of the crack/joint/void and using finishing nails, warm glue or silicone, fix Sika ® Injection 'T' ports at 15 - 20 cm (6 - 8 in ) intervals. Ensure each port is centered across crack and port is not blocked. Temporarily place plastic plugs supplied into the ports if there is potential for anything to enter and block injection ports. Plugging the Crack - Wet crack/joint/void thoroughly with clean water to ensure adhesion of Sikaset ® Plug. Surfaces must be saturated but clear of standing water when plugging mortar is applied. Mix Sikaset ® Plug powder with clean, cold water in ratio of 1 part water to 3 parts powder by volume and to the consistency of stiff putty. Apply without delay a layer thickness of 6 mm (1/4 in) around Sika ® Injection 'T' ports and 3 mm (1/8 in) along complete face of the crack. Note: Mortar dries rapidly (1 1/2 - 2 minutes) so it is recommended that it is mixed and applied in manageable quantities. Allow the quick-set, plugging mortar to set and harden for at least 30 minutes before injecting.

Upload: nyu123456

Post on 11-Nov-2015

5 views

Category:

Documents


2 download

DESCRIPTION

sikadur

TRANSCRIPT

  • SikaFix Kit

    Cons

    truct

    ion

    Product Data SheetEdition 06.2011/v2SikaFix Kit

    SikaFix KitInjection Repair Kit for Leaking Foundations

    Description The SikaFix Kit is an injection package for the repair of leaking cracks, static joints and voids, such as those in foundations. The kit includes a two-part polyurethane grout which expands in the presence of moisture to form a tough, flexible foam that firmly bonds to surfaces and seals against water.

    Where to Use The SikaFix Kit permanently stops the flow of unwanted water penetrating into or through: Foundationandbasementwalls. Crackedorhoneycombedconcrete. Concreteandmasonrysurfaces. Pipeandutilitiesintrusions.Wastewaterorseptictanks.

    Advantages Economicalandeasytoapply. Completekitsupplied,noothermaterialsneeded. Doesnotrequirespecializedequipment. Hydrophobic-onlyasmallamountofwaterisneededforreaction. Lastingadhesiontowetanddrysurfaces. Zeroshrinkagemaintainswatertightness. Permanentlyflexibleandtoughseal. Environmentallyfriendly;curedproductisinert.

    Technical DataPackaging Kit includes: 250mL(8.45USfl.oz)cartridgeofSikaFixPUpolyurethanegrout

    1kg(2.2lb)bagofSikasetPlugquick-setmortar20 Sika Injection 'T' ports with plugsInstructionSheetandDVD

    Colour Mortar:ConcreteGreyGrout:LightAmber

    Yield 2cracksmeasuring2.4m(8ft)longx200mm(8in)deepx3mm(1/8in)wide.Shelf Life 12monthsinoriginal,unopenedpackaging.Storebetween10-32C(50-90F)

    inadryplace.Protectfromfreezing.Iffrozendiscard.Properties at 23C (73F) and 50% R.H. (SikaFixPU)Open Time Approx.5hours,providingnomoistureentersthecartridge.Shrinkage ASTM D1623 0%Elongation 25%Water Absorption 0.19kg/m2

    How to Use Surface Preparation

    Forcracks,jointsorvoidslessthan6mm(1/4in)wide,createaVnotchatleast6mm(1/4in)wideand13mm(1/2in)deepusingananglegrinder,disccutterorsharp,handchippingtool.

    Cleanallcrackswellwithawirebrush to removealldust, laitance(thincement film),curingcompounds, loose, friable and foreign particles, grease and any material which would obstruct bond of mortar and penetration of grout.

    Substrates should be clean and sound and moisture must be present to bond the mortar and activate the grout.

    Application Fixing of Sika Injection 'T's - Starting from bottom of the crack/joint/void and using finishing nails, warm glue or silicone, fix Sika Injection 'T'portsat15-20cm(6-8in)intervals.

    Ensure each port is centered across crack and port is not blocked. Temporarily place plastic plugs supplied into the ports if there is potential for anything to enter and block injection ports.

    Plugging the Crack - Wetcrack/joint/voidthoroughlywithcleanwatertoensureadhesionofSikasetPlug.Surfacesmustbesaturatedbutclearofstandingwaterwhenpluggingmortaris applied.

    Mix SikasetPlugpowderwithclean,coldwaterinratioof1partwaterto3partspowderbyvolume and to the consistency of stiff putty.

    Applywithoutdelayalayerthicknessof6mm(1/4in)aroundSika Injection 'T'portsand3mm(1/8in)alongcompletefaceofthecrack.

    Note:Mortardriesrapidly(11/2-2minutes)soitisrecommendedthatitismixedandappliedinmanageablequantities.

    Allowthequick-set,pluggingmortartosetandhardenforatleast30minutesbeforeinjecting.

  • SikaFix Kit

    Cons

    truct

    ion

    The information, and in particular, the recommendations relating to the application and end-use of Sika products, are given in goodfaithbasedonSikascurrentknowledgeandexperienceoftheproductswhenproperlystored,handledandappliedundernormal conditions, within their shelf life. In practice, the differences in materials, substrates and actual site conditions are such that nowarrantyinrespectofmerchantabilityoroffitnessforaparticularpurpose,noranyliabilityarisingoutofanylegalrelationshipwhatsoever, can be inferred either from this information, or from any recommendations, or from any other advice offered. The proprietaryrightsofthirdpartiesmustbeobserved.Allordersareacceptedsubjecttoourcurrenttermsofsaleanddelivery.UsersshouldalwaysrefertothemostrecentissueoftheProductDataSheetfortheproductconcerned,copiesofwhichwillbesuppliedonrequestorcanbeaccessedintheInternetunderwww.sika.ca.

    1-800-933-SIKAwww.sika.ca

    An ISO 9001 certified companyPointe-Claire : ISO 14001 certified EMS

    Sika Canada Inc.Quebec601DelmarAvenuePointe-Claire,QCH9R4A9Tel.:514-697-2610Fax:514-697-3087

    Ontario6915DavandDriveMississauga, ON L5T 1L5Tel.:905-795-3177Fax:905-795-3192

    Alberta18131114thAvenueN.W.Edmonton,ABT5S1T8Tel.:780-486-6111Fax:780-483-1580

    Preparation of Grout - Unscrew threaded cap from SikaFixPUcartridgeandthenremoveplasticplug.Bothcapandplugmustbekeptifnotusingallgroutincartridgeatonetime.

    Attachthestaticmixingnozzlesuppliedandreplacethethreadedcapoverthenozzle.Screwcap tightly to prevent leakage.

    Load the cartridge into a suitable caulking gun.

    Wheninjectionworkiscompleted,removethreadedcapandthestaticmixingnozzle.Replaceplastic plug and cap to allow future use.

    Injecting the Crack - IMPORTANT: Thoroughly pre-wet crack/joint/void with clean water to ensure Sikafix PU will expand and form a sealing foam, as required. SikaFix PU WILL NOT EXPAND WITHOUT WATER. RemoveanytemporarilyplacedplugsfromportsandinserttipofcartridgenozzleintolowestSika Injection 'T'(No.1)tostartinjecting.

    Pump the trigger 3 timesand then stop to allowSikaFixPUgrout to penetrate.Wait 3 - 4minutesfortheliquidresintoexpand.Asthegroutentersthecrack,waterisdisplacedaheadof it.

    Once all water is released, SikaFixPUwilloccupypartof thecrackandpartiallyexpandedresin will exit from the next Sika Injection 'T'up(No.2).

    WhenresinstartstoexitfromSika Injection 'T'(No.2)above,placeaplasticplugintoSika Injection 'T'(No.1).

    Inject grout into Sika Injection 'T'(No.2),pumpingtrigger3timesandwaiting3-4minutesforreaction, until partially expanded resin starts to exit Sika Injection 'T'(No.3)above.

    PlaceplasticplugintoSika Injection 'T'(No.2)andcontinueinthesamemanneruntilallSika Injection 'T' ports have been injected and securely plugged to prevent leakage of unreacted grout resulting in unfilled cracks.

    Excess SikaFix PUappearingonthesurfaceofcrackscanbeeasilyremovedusingasharpknife when grout has stopped foaming.

    Note: Owing to there being two resin containers within the grout cartridge, it may appear that onlyhalfoftheliquidhasbeendispensedwheninfactthecontainerisempty.

    Clean Up Useeitherasolvent-basedcleanerorcleanclothtoremoveun-reactedgrout.Curedresincanonly be removed mechanically.

    Limitations Minimum substrate temperature 5C(41F). Minimummaterialtemperature15C(59F). Curedfoamshouldbeprotectedfromsunlight. Confined,reactingSikaFixPUcanproduceupto3100KPa(450psi)pressure. Caremustbetakenwhenhandlingcement-basedmaterialsandresins. Foranyapplicationincontactwithpotablewater,consultSikaCanadaTechnicalServices.

    Health and Safety Information

    For information and advice on the safe handling, storage and disposal of chemical products, users should refer to the product label and the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data.

    KEEPOUTOFREACHOFCHILDRENFORINDUSTRIALUSEONLY