  • GROUND

    100 AT

    USE 2 - 22 mm square THHN wire

    TO THE NEAREST POWER SOURCE

    215 AT 15 AT

    4

    1

    3

    M

    65

    L.O. L.O.

    SPARESPARE

    L.O. L.O.

    L.O. L.O.

    L.O.

    C.O.

    87

    109

    1211C.O.

    REF.

    RANGE

    C.O.

    15 AT 15 AT

    15 AT 15 AT

    15 AT 15 AT

    15 AT 30 AT

    15 AT 15 AT

    BRANDS.PURPOSE OF INDICATING THE DESIRED QUALITY BUT NOT TO LIMIT THE USE OF OTHER

    BRAND NAMES MENTIONED IN THE PLANS AND SPECIFICATIONS ARE ONLY FOR THE

    BLACK, BLUE AND RED. FOR GROUND WIRE GREEN OR WHITE.

    DEMS TO BE USED.

    APPLICATION.

    APPROVAL PRIOR TO THE INSTALLATION.

    B.) CONVENIENCE OUTLET ........... 0.30 M. ABOVE FLR. FIN. OR AS REQUIRED

    A.) LIGHTING SWITCHES ............... 1.40 M. ABOVE FLOOR FINISH

    THE MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS :

    BALLAST. LAMP SHALL BE COOL WHITE THROUGHOUT SPECIFIED AREA OF

    D.) KILOWATTHOUR METER .......... MIN. OF 1.2 M., MAX. OF 1.8 M. ABOVE FLOOR LINE. ALL

    C.) PANEL BOARDS & CABINETS... 1.60 M. ABOVE FLR. FIN. @ CENTER OR AS REQUIRED

    OTHERWISE INDICATED. THE MINIMUM SIZE FOR POWER CABLE SHALL BE 3.5 SQ. MM.

    WIRES SHOULD BE COLOR CODED. RECOMMENDED COLOR FOR POWER FEEDERS ARE

    ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE " THWN " UNLESS

    BY THE BUREAU OF PRODUCT STANDARDS (BPS) OF THE DEPARTMENT OF TRADE AND

    ONLY BRAND NEW DEVICES, EQUIPMENT MATERIALS AND SUPPLIES (DEMS) APPROVED

    THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE

    ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH

    MOUNTING HEIGHTS SHALL BE SUBJECTED TO THE ARCHITECT'S / ENGINEER'S

    ALL FLUORESCENT FIXTURES SHALL HAVE HIGH POWER FACTOR AND PRE - HEAT

    REQUIRED, THE SUPPLIER SHOULD FURNISH PROOFS REGARDING THE QUALITY OF

    RECOGNIZED TESTING ORGANIZATION SHALL BE USED IN THE PROJECT WHEN

    INDUSTRY (DTI) OR FOREIGN MADE PRODUCTS APPROVED BY INTERNATIONALLY

    SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER / MASTER ELECTRICIAN.

    REGULATIONS OF ENFORCING LOCAL GOVERNMENT, AND UNDER THE IMMEDIATE

    FIRE CODE OF THE PHILIPPINES, THE NATIONAL BUILDING CODE, THE RULES AND

    GENERAL SPECIFICATIONS

    PRESENTED BY:

    EVSU_CAAD_BSAR 4A STUDENT

    SUBJECT: PROJECT TITLE:

    LOCATION:

    CHECKED BY:

    DATE CHECKED:

    SHEET CONTENTS: SHEET NO.

    ELECTRICAL

    SCALE

    MANAGBANAG, EMMANUEL II L.MAGALLANES, EDRALYN COMP

    413TWO - STOREY RESIDENTIAL BLDG. ARCH. HERVY G. CATILOGO, UAP

    INSTRUCTOR

    E36 20

    RISER DIAGRAM NOT DRAWN TO SCALE

    TWO - STOREY RESIDENTIAL BLDG.

    E20 24

    RISER DIAGRAM N.D.T.S.

    GENERAL SPECIFICATION N.D.T.S.

    N.D.T.S.