sgt5-4000f gas turbine€¦ · four stages with film cooling and thermal barrier coatings:...

1
siemens.com/gasturbines SGT5-4000F gas turbine Trusted technology, achieved with permanent development Combustion Dry-Low-NO X hybrid burners, for low emission operation with gaseous and liquid fuels Homogeneous combustor outlet profile for minimized mechanical and thermal turbine stress Annular walk-in combustion chamber with individually replaceable heat shields for easy maintenance and short outages, resulting in highest availability Bearings Hydraulic Clearance Optimization (HCO) improves performance and minimizes degradation by active control of clearances at start-up and shut down Turbine High cycling capability due to fully air-cooled hot gas path without cooling air coolers Four stages with film cooling and thermal barrier coatings: Well- balanced turbine load optimizes life-cycle costs Performance Serviceability Flexibility PGGT-Y10015-01-7600 Compressor Proven 15-stage compressor: Fast cycling capability through fast acting inlet guide vane Two additional stages of fast-acting variable-pitch guide vanes (VGV) for improved part load efficiency and high load transients All rotating compressor blades replaceable without rotor lift or rotor de-stacking Rotor Robust design with internal cooling air passages for trusted long term operation and fast start-up capability Easy rotor de-stacking on site due to disc assembly with Hirth serration and central tie rod

Upload: others

Post on 16-Jul-2020

30 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: SGT5-4000F gas turbine€¦ · Four stages with film cooling and thermal barrier coatings: Well-balanced turbine load optimizes life-cycle costs Flexibility Performance Serviceability

siemens.com/gasturbines

SGT5-4000F gas turbineTrusted technology, achieved with permanent development

Combustion

Dry-Low-NOX hybrid burners, for low emission operation with gaseous and liquid fuels

Homogeneous combustor outlet profile for minimized mechanical and thermal turbine stress

Annular walk-in combustion chamber with individually replaceable heat shields for easy maintenance and short outages, resulting in highest availability

Bearings

Hydraulic Clearance Optimization (HCO) improves performance and minimizes degradation by active control of clearances at start-up and shut down

Turbine

High cycling capability due to fully air-cooled hot gas path without cooling air coolers

Four stages with film cooling and thermal barrier coatings: Well-balanced turbine load optimizes life-cycle costs

Performance ServiceabilityFlexibility PGG

T-Y

10

01

5-0

1-7

60

0

Compressor

Proven 15-stage compressor: Fast cycling capability through fast acting inlet guide vane

Two additional stages of fast-acting variable-pitch guide vanes (VGV) for improved part load efficiency and high load transients

All rotating compressor blades replaceable without rotor lift or rotor de-stacking

Rotor

Robust design with internal cooling air passages for trusted long term operation and fast start-up capability

Easy rotor de-stacking on site due to disc assembly with Hirth serration and central tie rod