1 / 2 Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast Dear Our Valued Clients, We appreciate your unwavering support and cooperation rendered to our Ballast Water Treatment System businesses. As the maker of HiBllast, we have produced the trouble shooting manual, consisting of 5 major categories as below ; Elecrolysis Unit Filter Unit Neutralization Unit TRO Sensor Unit Rectifier Whenever any alarm appears on the display monitor, you can just find the same alarm tag in the Table of Alarm and turn to the corresponding page to follow the trouble shooting instructions. We also attached photos and diagrams at the later part of this manual for your easy reference. It is intended to help you become acquainted as easily as with the ins and outs of the product and use it properly. Since this manual will have been revised continuously, if you have any suggestions, other useful information or you cannot clear the problem with this trouble shooting manual, please don’t hesitate to contact Green Service Team : Centum Science Park, 79, Centum jungang-ro, Haeundae-gu, Busan 48058, Korea Tel : +82 52 204 7765 / FAX: +82 52 204 7801 / Web : http://www.hyundai-gs.com/ E-MAIL : [email protected]

Upload: others

Post on 13-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

1 / 2

Service Letter

Date : Sep 20, 2018

Ref. No.: HGS-BWTS-SL-18-0001

Subject : Trouble Shooting Manual

Type : HiBallast

Dear Our Valued Clients,

We appreciate your unwavering support and cooperation rendered to our Ballast Water

Treatment System businesses.

As the maker of HiBllast, we have produced the trouble shooting manual, consisting of 5 major

categories as below ;

Elecrolysis Unit

Filter Unit

Neutralization Unit

TRO Sensor Unit

Rectifier

Whenever any alarm appears on the display monitor, you can just find the same alarm tag in

the Table of Alarm and turn to the corresponding page to follow the trouble shooting instructions.

We also attached photos and diagrams at the later part of this manual for your easy reference. It

is intended to help you become acquainted as easily as with the ins and outs of the product and

use it properly.

Since this manual will have been revised continuously, if you have any suggestions, other useful

information or you cannot clear the problem with this trouble shooting manual, please don’t

hesitate to contact Green Service Team :

Centum Science Park, 79, Centum jungang-ro, Haeundae-gu, Busan 48058, Korea Tel : +82 52 204 7765 / FAX: +82 52 204 7801 / Web : http://www.hyundai-gs.com/ E-MAIL : [email protected]

Page 2: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

2 / 2

Green Service Team

Tel +82 52 204 7630

Email [email protected]

Faithfully yours,

J.W Chung, General Manager

Technical Warranty Department

http://www.hyundai-gs.com/

Page 3: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

[This publication or any part there of may not be reproduced or transmitted by any pr

ocess or means without prior written permission of Hyundai Heavy Industries Co., Ltd.]

TROUBLESHOOTING

MANUAL FOR

HiBallast SYSTEM

REV.01

Page 4: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

PREFACE

Dear Our Valued Clients,

We appreciate your unwavering support and cooperation rendered to our Ballast Water Treatment

System businesses.

As the maker of HiBllast, we have produced this manual, consisting of 5 major categories as below,

Elecrolysis Unit

Filter Unit

Neutralization Unit

TRO Sensor Unit

Rectifier

Whenever any alarm appears on the display monitor, you can just find the same alarm tag in the

Table of Alarm and turn to the corresponding page to follow the trouble shooting instructions. We

also attached photos and diagrams at the later part of this booklet for your easy reference. It is

intended to help you become acquainted as easily as with the ins and outs of the product and use

it properly.

If you have any suggestions, other useful information or you cannot clear the problem with this

trouble shooting manual, please don’t hesitate to contact us:

Head office

Centum Science Park, 79, Centum Jungang-ro,

Haeundae-gu, Busan 48058, Rep. of Korea

Tel +82 52 204 7600~1, Fax +82 52 204 7700

https://www.hyundai-gs.com

Thank you

Technical Division

Tel +82 52 204 7852

E-mail [email protected]

Green Service Team

Tel +82 52 204 7630

E-mail [email protected]

Page 5: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

TABLE OF ALARM

1. ALARM LIST OF ELECTROLYSIS UNIT ................................................................................................... - 7 -

1.1. TAG: [AIT-1121_HI] / [AIT-1121_HH] ........................................................................................................................................ - 7 -

1.2. TAG: [B-117A/B-F] / [B-117A/B-OFF] ...................................................................................................................................... - 7 -

1.3. TAG: [BST_S_TO_01] / [BST_P_TO_01] / [BSP_S_TO_10] / [BSP_P_TO_10] / [BLR_BOTH_F] ............. - 7 -

1.4. TAG: [CIT-1111_LO] / [CIT-1111_LL] ........................................................................................................................................ - 8 -

1.5. TAG: [FIT-1131(2131)_LO] / [FIT-1131(2131)_LL] ............................................................................................................. - 8 -

1.6. TAG: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL] .............................................................................................................. - 9 -

1.7. TAG: [BSP_S/P_TO_08] .............................................................................................................................................................. - 10 -

1.8. TAG: [LS-1111_LL] ......................................................................................................................................................................... - 10 -

1.9. TAG: [LS-1141_HI] .......................................................................................................................................................................... - 11 -

1.10. TAG: [PIT-1121_HI] ......................................................................................................................................................................... - 11 -

1.11. TAG: [PIT-1121_LO] ....................................................................................................................................................................... - 12 -

1.12. TAG: [TE-1111_HI] / [TE-1111_HH] ......................................................................................................................................... - 13 -

1.13. TAG: [TE-1111_LO] ......................................................................................................................................................................... - 13 -

2. ALARM LIST OF FILTER UNIT ................................................................................................................ - 14 -

2.1. TAG: [FUBV_OP_AL] .................................................................................................................................................................... - 14 -

2.2. TAG: [BST_S/P_TO_02] / [BSP_S_TO_06] ........................................................................................................................ - 14 -

2.3. TAG: [DST_S_TO_01] OR [DSP_S_TO_04] ....................................................................................................................... - 15 -

2.4. TAG: [FU_DP_HH] / [FU_DP_HI] ............................................................................................................................................. - 15 -

2.5. TAG: [F-121(122)-F] ....................................................................................................................................................................... - 16 -

2.6. TAG: [F-121/221-RDY] .................................................................................................................................................................. - 17 -

2.7. TAG: [FU_IN_HI] / [FU_IN_LO] / [FU_OUT_HI] / [FU_OUT_HH] ............................................................................... - 17 -

3. ALARM LIST OF NEUTRALIZATION UNIT............................................................................................. - 18 -

3.1. TAG: [LIT-1311_LO] / [LIT-1311_LL] ...................................................................................................................................... - 18 -

3.2. TAG: [P-132(232/332)-TRIP] ...................................................................................................................................................... - 18 -

3.3. TAG: [NUPD_S(P/AP)_TO] / [ NUPS_TO] / [NUPD_S(P/AP)_SP_TO] / [ NUPS_SP_TO] ............................. - 19 -

4. ALARM LIST OF TRO SENSOR UNIT .................................................................................................... - 20 -

4.1. TAG: [TRO_LL] / [TRO_LO] ....................................................................................................................................................... - 20 -

4.2. TAG: [TRO_HI] / [TRO_HH] FOR BALLASTING ...................................................................................................................... - 21 -

4.3. TAG: [TRO_HI] / [TRO_HH] FOR DE-BALLASTING ............................................................................................................... - 21 -

5. ALARM LIST OF RECTIFIER .................................................................................................................. - 22 -

5.1. TAG: [R1(2/3)_COMM_ERR] / [BSP_S/P_TO_01] / [BST_S/P_TO_14] ................................................................ - 22 -

5.2. TAG: [RF-A/B/C/D_ERR] ............................................................................................................................................................. - 22 -

Page 6: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

5.3. TAG: RF-[RF-A(B/C/D)-1002] / [REC1(2/3/4)002] ............................................................................................................ - 22 -

5.4. TAG: [RF-A(/B/C/D)-1007] / [REC-1(2/3/4)007] ................................................................................................................. - 23 -

5.5. TAG: [RF-A/B/C/D-1004] / [REC-1(2/3/4)004] .................................................................................................................... - 23 -

Page 7: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 7 -

1. Alarm List of Electrolysis Unit

1.1. TAG: [AIT-1121_HI] / [AIT-1121_HH]

Description [AIT-1121(22/23)_HI] AIT-1121/22/23 GAS DETECTOR HI

[AIT-1121(22/23)_HH] AIT-1121/22/23 GAS DETECTOR TOO HI

Information It will be activated when the density of H2 gas goes over than the set point.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. H2 ventilation pipe

blocked Check the venting pipe and the venting head N/A

2. Malfunction of the sensor 1) Check the input power of the sensor, DC24V.

2) Check the output signal, 4~20mA. N/A

3. Incorrect calibration 1) Calibration of H2 Gas Detector

T/S-H2-01

T/S-H2-02

1.2. TAG: [B-117A/B-F] / [B-117A/B-OFF]

Description E.U NO.1 BLOWER FAULT

NO.1 BLOWER BREAKER OFF

Information It will be activated when the blower meets trip condition due to overload or

Breaker is off.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Over current fault 1) Check that the EOCR for the blower in the MCC-100 is tripped.

2) Check the set value of the EOCR.

T/S-BL-01

2. Motor fail 1) Check the power line.

2) Check the resistance of winding lines, R-S, S-T, R-T phases. If

incorrect, please replace the motor.

N/A

3. Input power off Check the input power is correctly provided to the blower.

1) Check the main MCCB of MCC-100.

2) Check the sub MCCB for the blower in MCC-100.

N/A

1.3. TAG: [BST_S_TO_01] / [BST_P_TO_01] / [BSP_S_TO_10] / [BSP_P_TO_10] / [BLR_BOTH_F]

Description BLOWER START/STOP TIME-OUT

BOTH BLOWER FAIL ON BALLASTING

Information It will be activated when the magnetic contactor of the blower does not On/Off

after receiving blower START/STOP and blowers STOP during ballasting.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Magnetic Contactor

fault

Check the magnetic contactor is working itself or not by using

MANUAL operation on the HMI. If not, please replace.

T/S-BS-01

Page 8: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 8 -

1.4. TAG: [CIT-1111_LO] / [CIT-1111_LL]

Description FEED WATER SALINITY LOW

FEED WATER SALINITY TOO LOW

Information It will be activated when the salinity to electrolysis is lower than 15PSU.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Incorrect salinity range

*Low salinity: < 15PSU

*Too low salinity: < 13PSU

If the salinity of feed water is lower than 15PSU and the sensor

is normal, In this case, the salt tank unit or the dedicated

seawater tank for backup salt source shall be used in low

salinity region.

N/A

2. Contamination of the

probe

1) Disconnect the cable and disassemble the CIT sensor’s

head.

2) Check the electrode of the probe and cleaning.

3) Assemble the probe and check again.

T/S-CIT-01

3. Incorrect calibration Recalibration of CIT Sensor. T/S-CIT-02

4. Sensor Fault 1) Check the input power of the sensor.

2) Check the output signal cable.

N/A

1.5. TAG: [FIT-1131(2131)_LO] / [FIT-1131(2131)_LL]

Description NO.1/2 INJECTION FLOW RATE LOW

NO.1/2 INJECTION FLOW RATE TOO LOW

Information The injection flow rate is lower than the set points.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Drain valve OPEN Please check the drain valve of electrolysis unit. If it is

opened, close it.

N/A

2. Incorrect position of the flow

control valve

Calibration of positioner. T/S-FIT-01

3. Manual valve CLOSE Check that the manual valve open status from Sea water

feed pump to E.U. injection point.

N/A

4. Water leakage of injection

pipe

Check if there is water leakage on the pipe line. N/A

5. Malfunction of the sensor 1) Check the DC24V input power of the sensor.

2) Check the analog signal connection and signal line.

For more information, please see the ref. manual.

N/A

6. Blockage of strainer of

SWFU

Check if the strainer is blocked or not in the seawater feed

unit. If clogged, clean it.

N/A

7. Too low of main stream flow Check if the flow rate of the main ballast stream is too low,

which may lead to high pressure of the main stream and

consequently it will make low injection flow.

N/A

Page 9: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 9 -

8. Malfunction of the sensor 1) Check the DC24V input power of the sensor.

2) Check the analog signal connection and signal line.

For more information, please see the ref. manual.

N/A

9. Flow unbalance of injection

lines

If the flow deviation between starboard and port side is big,

one of two injection lines might meet the alarm.

Confirm if the pressure deviation of filters is big or not,

higher than about 1.0 bar.

N/A

1.6. TAG: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Description NO.1/2 MAIN FLOW RATE LOW

NO.1/2 MAIN FLOW RATE TOO LOW

Information The injection flow rate is lower than the set points.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Drain valve OPEN Please check the drain valve of electrolysis unit. If it is

opened, close it.

N/A

2. Incorrect position of the flow

control valve

Calibration of positioner. T/S-FIT-01

T/S-FIT-02

T/S-FIT-03

T/S-FIT-04

3. Water leakage of injection

pipe

Check if there is water leakage on the pipe line. N/A

4. Malfunction of the sensor 1) Check the DC24V input power of the sensor.

2) Check the analog signal connection and signal line.

For more information, please see the ref. manual.

N/A

5. Blockage of filter unit 1) Do back-flushing using the ballast pump.

2) Check the filter elements are contaminated or not. If

then, please do cleaning according to the trouble shooting

manual.

T/S-FU-06

6. Malfunction of the sensor 1) Check the DC24V input power of the sensor.

2) Check the analog signal connection and signal line.

N/A

7. Incorrect setting of flow-

meter

Setting correctly. T/S-FIT-07

8. Loosed cable connection Connect cable. T/S-FIT-08

9. Electrode damage Check resistance T/S-FIT-09

Page 10: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 10 -

1.7. TAG: [BSP_S/P_TO_08]

Description INJ VALVE CLOSE TIME-OUT

Information It will be activated when it takes over 120sec to close the valve.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Incorrect position of the

flow control valve

Calibration of positioner. T/S-FIT-01

2. Air vent of the

positioner

Check if the air vent line of the positioner is blocked. N/A

3. Pressure low or fail of

the air supply

1) Check if the supply pressure of the pneumatic or hydraulic

for the valve is proper or not. (Recommended Pneu. pressure:

5~7kgf/cm2)

2) Check if the air filter is filled with water/oil or not by pressing

releasing button.

N/A

4. Stuck of the Disc and

Seat

1) In case that the supply pressure and the positioner are okay,

please be aware of possibility of the stuck of the DISC and

SEAT.

2) Disassemble and check inside of the valve.

N/A

1.8. TAG: [LS-1111_LL]

Description E.U SEPARATOR LEVEL TOO LOW

Information 1) It will be activated when the level switch(LS-1111) is OFF during ballasting

operation.

2) This level switch is very important to keep safe operation. Because the output

power of the rectifiers must be only energized while the level switch is ON.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. No feed water to

electrolysis unit

1) Check the discharge pressure of the seawater feed pump is

correct.

2) Check the valves on the seawater feed line to be OPEN.

Especially manual valves from the sea chest line.

3) Check the strainer on the SWFU.

4) Check the check valve at electrolysis unit inlet works correctly.

N/A

2. Injection flow

fluctuation due to filter

back-flushing

Check when this alarm is occurred. If this alarm occurred right after

filter’s back-flushing, increase injection flow control valve’s

minimum open ratio.

T/S-LS-01

4. Malfunction of the

sensor

1) Check the input power of the sensor is DC24V.

2) Check the output signal cable and connector.

3) Disassemble of the sensor and check the probe visually.

4) If the level switch does not work well in a bottle, replace it.

N/A

Page 11: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 11 -

1.9. TAG: [LS-1141_HI]

Description E.U DRAIN TANK LEVEL HIGH

Information 1) The alarm will be activated when the level switch(LS-1141) is ON(with Time

Delay=30sec). And then, the drain pump will be start.

2) The shutdown will be activated if the level switch(LS-1141) is still ON after the

drain pump starting.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Drain pump’s fault Check if the drain pump is working well or not. There are two type

drain pumps, air driven diaphragm pump and electric driven

pump.

For air driven pump, please check the air supply line, air regulator

and filter, solenoid valve and diaphragm pump. For electric driven

pump, please check the power line, relay and the motor.

N/A

2. Contamination of level

switch

Clean fork of level switch. T/S-LS-02

3. Blockage of the

feeding line

Check whether the tubing line of the drain pump discharge is

blocked or not.

N/A

4. Blockage of the check

valve

Check if the check valve is correctly working or not at the end of

the drain pump discharge.

N/A

5. Malfunction of the

sensor

1) Check the input power of the sensor is DC24V.

2) Check the output signal cable and connector.

N/A

1.10. TAG: [PIT-1121_HI]

Description BLOWER DISCHARGE PRESS HIGH

Information It will be activated when the difference pressure before/after blower starting is

higher than the specific valve. It means that the H2 ventilation pipe is blocked or

other cases.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Blockage of H2

venting line

1) Firstly confirm that the blower is running and the valve is

OPEN.

2) Check the H2 venting pipe’s outlet is blocked or not, especially

venting head if applicable.

N/A

2. Malfunction of

pressure sensor

1) Check the analogue output signal and connector. N/A

Page 12: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 12 -

1.11. TAG: [PIT-1121_LO]

Description BLOWER DISCHARGE PRESS LOW

Information It will be activated when the difference pressure before/after blower starting is

lower than the specific value in the ALARM setting value.

Causes Troubleshooting/Corrective Action T/S Tag

No.

1. Malfunction of the

sensor

1) Check the input power of the sensor, DC24V. If not, please

check the cable, connection, and the power supply in the CC-100.

2) Check the output signal cable(4~20mA).

3) Disassemble of the sensor and check if the probe visually is

broken or not.

N/A

Page 13: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 13 -

1.12. TAG: [TE-1111_HI] / [TE-1111_HH]

Description FEEDING WATER TEMP. HIGH

Information It will be activated when the feed water for electrolysis unit is higher than 38

deg. C for the high alarm and 55 deg. C for the shutdown, respectively.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Malfunction of the

sensor

1) Check the input power of the sensor.

2) Check the output signal cable.

N/A

2. Contamination of the

probe

1) Disassemble the measuring probe of the sensor.

2) Check the electrode of the probe and cleaning.

3) Assemble the probe and check again.

T/S-CIT-01

3. Abnormal valve

arrangement for heat

exchanger

Arrange valve correctly. Heat exchanger inlet valve(XV-1731) to

be closed and heat exchanger by-pass valve(XV-1732) to be

opened.

T/S-TE-01

4. Hot source water

temperature is too high

Check hot source water temperature. If it judged hotter than

design temperature(36 deg. C), reduce hot source water flow

rate by throttling manual butterfly valve.

T/S-TE-02

1.13. TAG: [TE-1111_LO]

Description FEED WATER TEMPERATURE LOW

Information It will be activated when the feed water for electrolysis unit is lower than 10

deg. C for the low alarm and 6 deg. C for the shutdown, respectively.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Malfunction of the

sensor

1) Check the input power of the sensor.

2) Check the output signal cable.

N/A

2. Contamination of the

probe

1) Disassemble the measuring probe of the sensor.

2) Check the electrode of the probe and cleaning.

3) Assemble the probe and check again.

T/S-CIT-01

3. Abnormal valve

arrangement for heat

exchanger

Arrange valve correctly. Heat exchanger bypass valve(XV-1732)

to be closed and heat exchanger inlet valve(XV-1731) to be

opened.

T/S-TE-01

4. Hot source water

temperature is too low

Check hot source water temperature. If it judged lower than

design temperature(36 deg. C), check central cooling system.

N/A

Page 14: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 14 -

2. Alarm List of Filter Unit

2.1. TAG: [FUBV_OP_AL]

Description F.U BYPASS V/V OPEN ALARM

Information 1) It will be activated when the filter bypass valve is OPEN during operation

or stand-by.

2) It will be activated when the filter bypass valve is OPEN for too long

time(120sec) during operation.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Manual open 1) Please close the bypass valve except an emergency

case T/S-FU-01

2. Incorrect position of limit

switch

1) Check the limit switch if the alarm happens without

any operation. T/S-FU-02

2.2. TAG: [BST_S/P_TO_02] / [BSP_S_TO_06]

Description 1) F/U VALVE OPEN TIME-OUT

2) F/U VALVE CLOSE TIME-OUT

Information It will be activated when the inlet/outlet valves of the filter unit is not working

after receiving OPEN/CLOSE command during ballasting. [TIME-

OUT.120sec]

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Pressure low or fail of the

pneumatic supply for the

valve

1) Check if the supply pressure of the pneumatic or

hydraulic for the valve is proper or not. Recommended

pneumatic pressure of the regulator: 5~7kgf/cm2.

T/S-FU-03

2. Input power fail of the

solenoid valve

1) Check if the input power, DC24V, is properly provided

or not.

2) If not, please check the power supply in the control

cabinet.

T/S-FU-04

3. Manual close or open 1) Please open or close the F/U valve. T/S-FU-01

4. Incorrect position of limit

switch 1) Check the limit switch. T/S-FU-02

5. Stuck of the Disc and

Seat

1) In case that the supply pressure and the solenoid

valve are okay, please be aware of possibility of the stuck

of the “DISC and SEAT”.

2) Disassemble and check inside of the valve.

N/A

Page 15: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 15 -

2.3. TAG: [DST_S_TO_01] OR [DSP_S_TO_04]

Description 1) F/U BYPASS VALVE OPEN TIME-OUT

2) F/U BYPASS VALVE CLOSE TIME-OUT

Information It will be activated when the bypass valve of the filter unit is not working after

receiving OPEN/CLOSE command during deballasting. [TIME-OUT.120sec]

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Pressure low or fail of the

pneumatic or hydraulic

supply for the valve

1) Check if the supply pressure of the pneumatic or

hydraulic for the valve is proper or not. Recommended

pneumatic pressure of the regulator: 5~7kgf/cm2.

T/S-FU-03

2. Input power fail of the

solenoid valve

1) Check if the input power, DC24V, is properly provided

or not.

2) If not, please check the power supply in the control

cabinet.

T/S-FU-04

3. Manual close or open 1) Open or close the FU bypass valve. T/S-FU-01

4. Incorrect position of limit

switch 1) Check the limit switch. T/S-FU-02

5. Stuck of the Disc and

Seat

1) In case that the supply pressure and the solenoid

valve are okay, please be aware of possibility of the stuck

of the “DISC and SEAT”.

2) Disassemble and check inside of the valve.

N/A

2.4. TAG: [FU_DP_HH] / [FU_DP_HI]

Description 1) FILTER PRESS DP. TOO HIGH

2) FILTER PRESS DP. HIGH

Information It will be activated when the differential pressure between inlet and outlet

pressure is over than alarm set value, 0.7bar for alarm and 1.0bar for

shutdown, respectively.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Back-flushing valve

fail

1) Check if the back-flushing valve is working or not by

pressing the “TEST” button on the filter LCP(local control

panel).

2) If not, please check the supply air and its pressure,

5~7kgf/cm2, is proper or not.

3) Check the solenoid valve and control signal.

T/S-FU-05

Page 16: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 16 -

2. Back-flushing motor

fault

1) Check if the MCCB for motor is “OFF” in the Filter Panel.

If “OFF”, please turn it “ON”.

2) Check if the error lamp of KM1 contactor is on or not

inside LCP after reset. If error keeps on, please check if

there is any foreign body interrupting rotation of the back-

flushing arm inside of the filter unit

3) Check the geared motor.

T/S-FU-06

3. Blockage of the air

vent

1) Check if the air vent hole is blocked or not. If blocked,

please remove a foreign blocking material.

T/S-FU-07

4. Blocking of the back-

flushing line

1) Check if the manual valves are OPEN on the back-

flushing line.

2) Check if the check valve is working or not.

N/A

5. Broken(hole) of the

back-flushing line

1) Check if there is a broken part or a hole in the back-

flushing line at lower part of filter unit inside.

N/A

6. Pressure sensor fail 1) Check if the inlet/outlet pressure sensors is working

properly.

2) If not, please check the cable and signal.

3) if not, please replace the sensor.

T/S-FU-08

7. Clogging of the filter

elements

1) Do backflushing using the ballast pump.

2) Check the filter elements are contaminated or not. If then,

please do cleaning according to the trouble shooting

manual.

T/S-FU-09

T/S-FU-10

2.5. TAG: [F-121(122)-F]

Description NO.1(2) FILTER (F-121/122) FAULT

Information It will be activated in case of filter fault.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Filter fault 1) Check the main switch in LCP

2) Check the terminal block with buzzer multimeter T/S-FU-11

2. CPU in stop mode alarm 1) EEPROM upgrade is required

T/S-FU-12

3. CPU not responding 1) Change the baud rate

T/S-FU-13

Page 17: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 17 -

2.6. TAG: [F-121/221-RDY]

Description NO.1(2) FILTER (F-121/122) NOT READY

Information It will be activated in case that the MCCB of filter in the LCP is OFF.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. MCCB OFF Check if the MCCB of filter is OFF or not. If OFF, please

turn it on. T/S-FU-14

2.7. TAG: [FU_IN_HI] / [FU_IN_LO] / [FU_OUT_HI] / [FU_OUT_HH]

Description 1) FILTER INLET PRESS HIGH

2) FILTER INLET PRESS LOW

3) FILTER OUTLET PRESS HIGH

4) FILTER OUTLET PRESS LOW

Information It will be activated when the pressure is higher than the set point.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Valve CLOSE Check if there are CLOSE valves on the filter outlet

piping line N/A

2. Room temperature high It will be activated when the room temperature rise high

at stand-by. If then, please release the pressure due to

high temperature by OPEN valves.

N/A

3. Wrong sensor scale Check if the sensor scale is correct or not in the Mimic. N/A

4. Filter element clogging 1) Do backflushing using the ballast pump.

2) Check the filter elements are contaminated or not. If

then, please do cleaning according to the trouble

shooting manual.

T/S-FU-09

T/S-FU-10

Page 18: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 18 -

3. Alarm List of Neutralization Unit

3.1. TAG: [LIT-1311_LO] / [LIT-1311_LL]

Description 1) NU-TANK LEVEL LOW

2) NU-TANK LEVEL TOO LOW

Information It will be activated when the level of the neutralization tank goes below than

the set point.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Low level of

neutralization

1) Check the level of the neutralization tank. If low, please fill

the neutralization agent.

N/A

2. Malfunction of the

sensor

1) If tank level is normal, please check the level sensor.

2) Check the input power and feedback signal.

T/S-NU-01

3. Drain valve OPEN Check if the drain valve is OPEN or not. If open, please close

it.

N/A

4. Leakage of the tank &

piping

Check if there is a leakage of the neutralization tank or piping. T/S-NU-02

5. Damage of float Check float status. If damaged, replace it. T/S-NU-03

3.2. TAG: [P-132(232/332)-TRIP]

Description [P-132(232/332)-TRIP] NO.1 (2/3) PUMP TRIP

Information It will be activated when N.U pump motor condition is tripped

Causes Troubleshooting/Corrective Action T/S Tag No.

1. No power supply Check power supply. T/S-NU-04

2. Fuse damage Check the fuse and replace it. T/S-NU-04

3. Disconnection or bad

connection of elect. cable Check and re-tight the wire connection N/A

4. Short circuit Check insulation resistance T/S-NU-05

4. Wrong mode setting Check Auto/Manual operation mode T/S-NU-06

Page 19: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 19 -

3.3. TAG: [NUPD_S(P/AP)_TO] / [ NUPS_TO] / [NUPD_S(P/AP)_SP_TO] / [ NUPS_SP_TO]

Description [NUPD_S(P/AP)_TO] NU PUMP RUN FAIL ON DEBAL S(P/AP)

[NUPS_TO] NU PUMP RUN FAIL ON DEBAL STRIPPING

[NUPD_S(P/AP)_SP_TO]. NU PUMP STOP FAIL ON DEBAL S(P/AP)

[ NUPS_SP_TO] NU PUMP STOP FAIL ON DEBAL STRIPPING

Information It will be activated when the pump does not start or stop properly during de-

ballasting operation

Causes Troubleshooting/Corrective Action T/S Tag No.

1. No power supply Check power supply. T/S-NU-04

2. Fuse damage Check the fuse and replace it. T/S-NU-04

3. Disconnection or bad

connection of elect.

cable

Check and re-tight the wire connection N/A

4. Short circuit Check insulation resistance T/S-NU-05

4. Wrong mode setting Check Auto/Manual operation mode T/S-NU-06

Page 20: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 20 -

4. Alarm List of TRO Sensor Unit

4.1. TAG: [TRO_LL] / [TRO_LO]

Description 1) TRO LOW / TRO TOO LOW

Information 1) Too low alarm when TRO injection is lower than 5PPM for 600sec delay

time.

2) Low alarm when TRO injection is less than 5.5PPM for 600sec delay

time.

3) TRO sensor alarm code (Local)

Message Description of fault

MA 4-20mA enabled & loop open

WATER No water flowing

FAST Intake water flow too fast

SLOW Sample cuvette filling too slowly

NPGR Sample cuvette not purging

GLAS Dirty cuvette

Causes Troubleshooting/Corrective Action T/S Tag No.

1. 4-20 mA enable & loop

open (Message : MA) Check analog output signal. T/S-TRO-07

2. No water flowing

(Message : WATR)

Check water flow T/S-TRO-01

Check TRO sol. valve and clean it. T/S-TRO-05

3. Intake water flow too fast

(Message : FAST) Check water flow T/S-TRO-01

4. Intake water flow too slow

(Message : SLOW) Check water flow T/S-TRO-1

5. Sample cuvette not purging

(Message : NPRG) Check drain line of TRO sensor T/S-TRO-06

6. Dirty cuvette

(Message : GLAS) Check the cuvette and clean if needed T/S-TRO-04

7. Expired reagent life time

or no reagent

The reagent shall be replaced periodically as below.

Indicator : every 3 months / Buffer : 1 year, respectively. T/S-TRO-02

8. Check valve clogging Check the check valve and clean if needed T/S-TRO-03

Page 21: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 21 -

4.2. TAG: [TRO_HI] / [TRO_HH] for ballasting

Description 1) TRO HIGH

2) TRO TOO HIGH

Information 1) Too high alarm when TRO injection dosage is more than 10PPM for

600sec delay time.

2) High alarm when TRO injection dosage is more than 9PPM for 600sec

delay time.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Too high current value of

rectifier.

1) Check if the output current on the rectifier during

operation to electrolyzer modules is within proper range.

2) If this alarm occurs at initial startup procedure, please

reduce 10A of the initial set value of the rectifier. And

repeat.

T/S-TRO-08

4.3. TAG: [TRO_HI] / [TRO_HH] for de-ballasting

Description 1) TRO HIGH

2) TRO TOO HIGH

Information 1) Too high alarm when TRO injection dosage is more than 0.1PPM for

600sec delay time.

2) High alarm when TRO injection dosage is more than 0.08PPM for 300sec

delay time.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Solenoid vale in

neutralizer unit is clogged.

Clean solenoid valve.

T/S-TRO-09

2. Wrong manual valve

arrangement

Arrange manual valve correctly. T/S-TRO-10

3. Wrong setting of dosing

pump stroke dial.

Set dosing pump stroke correctly. T/S-TRO-11

Page 22: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 22 -

5. Alarm List of Rectifier

5.1. TAG: [R1(2/3)_COMM_ERR] / [BSP_S/P_TO_01] / [BST_S/P_TO_14]

Description NO.1(2/3) RECTIFIER COMM. ERROR

RECTIFIER STOP TIME-OUT

RECTIFIER START TIME-OUT

Information It will be activated when RS-485 communication error is occurred between

ACONIS and rectifier.

It will be activated when the rectifier does NOT stop after receiving STOP-

command from ACONIS controller. The STOP command shall be activated

by the digital output OR communication command from the PLC controller,

where the rectifier model is to be Remote mode.

It will be activated when the rectifier does NOT start after receiving START-

command from ACONIS controller thru communication. The START

command shall be activated by the digital output AND communication

command from the PLC controller, where the rectifier model is to be Remote

mode.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Disconnection or bad

connection of elect. cable Check and re-tight the wire connection T/S-REC-01

2. Wrong operation mode Check operation mode to “AUTO/REMOTE” T/S-REC-02

3. PCB malfunction Check “ID selection” and LED status on PCB T/S-REC-03

4. HiSCM card malfunction Check LED status of HiSCM and reset. T/S-REC-04

3. System freezing Off and on rectifier N/A

5.2. TAG: [RF-A/B/C/D_ERR]

Description RF-142A(B/C/D) ERROR

Information It will be activated when the rectifier meets an alarm itself.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Internal problem Check error code of local panel and contact to Hyundai

Global Service. N/A

5.3. TAG: RF-[RF-A(B/C/D)-1002] / [REC1(2/3/4)002]

Description RF-142A(B/C/D) EXTERNAL E-STOP

Information The external E-STOP comes from the ACONIS controller via the digital

signal or communication command.

Causes Troubleshooting/Corrective Action T/S Tag No.

Page 23: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 23 -

1. External Emergency stop

1) Remove emergency stop condition from rectifier

outside.

2) Reset rectifier.

T/S-REC-05

5.4. TAG: [RF-A(/B/C/D)-1007] / [REC-1(2/3/4)007]

Description RF-142A/B/C/D U.C.(UNBALANCE CURRENT) ALARM

Information It will be activated when the current difference between electrolyzer modules

is higher than the limit, 50% of a quarter of total output current. Where the

ACONIS controller will receive this information from the rectifier via

communication.

E.g., total output current=200A

Limit of U.C. = (200/4)/2 = 25A

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Loosen of output cable

connection

Check if the output power cables are loosed. Compare

actual shunt value and MIMIC value. T/S-REC-06

2. Unstable connection of

power feeder of electrolyzer

module

Check cable tightness of the power feeder.

T/S-REC-07

3. Mis-arrangement of

manual valve.

Check the manual valve of electrolyzer outlet is open. T/S-REC-08

4. Electrolyzer scale

formation

Acid cleaning of electrolyzer T/S-REC-09

5.5. TAG: [RF-A/B/C/D-1004] / [REC-1(2/3/4)004]

Description RF-142A/B/C/D OUTPUT O.V. (Over Voltage) ALARM

Information It will be activated when the output voltage of the rectifier is higher than the

hardware limit. Where the ACONIS controller will receive this information

from the rectifier via communication.

Causes Troubleshooting/Corrective Action T/S Tag No.

1. Electrolyzer scale

formation

Acid cleaning of electrolyzer T/S-REC-09

2. Elecrode’s life has

ended.

Replace electrode. Contact Hyundai Global Service. N/A

Page 24: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

APPENDIX

Page 25: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

TABLE OF TROUBLE SHOOTING

T/S-H2-01 ........................................................................................................................................................................................................... - 29 -

T/S-H2-02 ........................................................................................................................................................................................................... - 32 -

T/S-BL-01 ........................................................................................................................................................................................................... - 33 -

T/S-BS-01 ........................................................................................................................................................................................................... - 34 -

T/S-CIT-01 .......................................................................................................................................................................................................... - 35 -

T/S-CIT-02 .......................................................................................................................................................................................................... - 36 -

T/S-FIT-01 ........................................................................................................................................................................................................... - 40 -

T/S-FIT-02 ........................................................................................................................................................................................................... - 43 -

T/S-FIT-03 ........................................................................................................................................................................................................... - 44 -

T/S-FIT-04 ........................................................................................................................................................................................................... - 45 -

T/S-FIT-05 ........................................................................................................................................................................................................... - 46 -

T/S-FIT-06 ........................................................................................................................................................................................................... - 50 -

T/S-FIT-07 ........................................................................................................................................................................................................... - 52 -

T/S-FIT-08 ........................................................................................................................................................................................................... - 53 -

T/S-LS-01 ........................................................................................................................................................................................................... - 54 -

T/S-LS-02 ........................................................................................................................................................................................................... - 55 -

T/S-TE-01 ........................................................................................................................................................................................................... - 56 -

T/S-TE-02 ........................................................................................................................................................................................................... - 57 -

T/S-FU-01 ........................................................................................................................................................................................................... - 58 -

T/S-FU-02 ........................................................................................................................................................................................................... - 59 -

T/S-FU-03 ........................................................................................................................................................................................................... - 60 -

T/S-FU-04 ........................................................................................................................................................................................................... - 61 -

T/S-FU-05 ........................................................................................................................................................................................................... - 65 -

T/S-FU-06 ........................................................................................................................................................................................................... - 66 -

T/S-FU-07 ........................................................................................................................................................................................................... - 68 -

T/S-FU-08 ........................................................................................................................................................................................................... - 69 -

T/S-FU-09 ........................................................................................................................................................................................................... - 71 -

T/S-FU-10 ........................................................................................................................................................................................................... - 72 -

T/S-FU-11 ........................................................................................................................................................................................................... - 79 -

T/S-FU-12 ........................................................................................................................................................................................................... - 81 -

T/S-FU-13 ........................................................................................................................................................................................................... - 83 -

T/S-FU-14 ........................................................................................................................................................................................................... - 85 -

T/S-TRO-01........................................................................................................................................................................................................ - 86 -

T/S-TRO-02........................................................................................................................................................................................................ - 88 -

T/S-TRO-03........................................................................................................................................................................................................ - 90 -

Page 26: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

T/S-TRO-04........................................................................................................................................................................................................ - 92 -

T/S-TRO-05........................................................................................................................................................................................................ - 94 -

T/S-TRO-06........................................................................................................................................................................................................ - 95 -

T/S-TRO-07........................................................................................................................................................................................................ - 96 -

T/S-TRO-08........................................................................................................................................................................................................ - 99 -

T/S-TRO-09..................................................................................................................................................................................................... - 101 -

T/S-TRO-10..................................................................................................................................................................................................... - 103 -

T/S-TRO-11 ..................................................................................................................................................................................................... - 104 -

T/S-NU-01 ........................................................................................................................................................................................................ - 105 -

T/S-NU-02 ........................................................................................................................................................................................................ - 110 -

T/S-NU-03 ........................................................................................................................................................................................................ - 112 -

T/S-NU-04 ........................................................................................................................................................................................................ - 113 -

T/S-NU-05 ........................................................................................................................................................................................................ - 114 -

T/S-NU-06 ........................................................................................................................................................................................................ - 115 -

T/S-REC-01..................................................................................................................................................................................................... - 116 -

T/S-REC-02..................................................................................................................................................................................................... - 117 -

T/S-REC-03..................................................................................................................................................................................................... - 118 -

T/S-REC-04..................................................................................................................................................................................................... - 119 -

T/S-REC-05..................................................................................................................................................................................................... - 121 -

T/S-REC-06..................................................................................................................................................................................................... - 123 -

T/S-REC-07..................................................................................................................................................................................................... - 125 -

T/S-REC-08..................................................................................................................................................................................................... - 126 -

T/S-REC-09..................................................................................................................................................................................................... - 127 -

Page 27: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 29 -

T/S-H2-01

Alarm Tag.: [AIT-1121(1122/1123)_HI] / [AIT-1121(1122/1123)_HH]

Root Cause: Incorrect reading

Trouble Shooting: Calibration of H2 Gas Detector(Model : DA100)

1. Open the detector cover by rotating it to

counter clockwise as below.

2. Connect all calibration devices with gas

detector. (standard gas, regulator, nipple

and tube)

3. Zero Calibration.

3.-1 Press [ENT] key over 3 seconds,

Then, 'H.SC' will Be shown.

3-2. Press [Mode] key repeatedly until 'CA1'

is shown and then press [ENT] key to

save.

3-3. When 'YES' is shown on FND, Please

press

[ENT] key to complete zero calibration.

Page 28: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 30 -

4. SPAN Calibration.

4-1. Please infuse standard gas

4-2. The value of FND will be increased.

4-3. Press [ENT] key over 3 seconds, Then,

'H.SC' will be shown.

4-4. Press [Mode] key until 'CA2' is shown

and then press [ENT] key to save.

4-5. When 'ADJ' is shown, Please set the

density of standard gas by pressing

[UP] key & [DOWN] key.

Page 29: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 31 -

Caution: In case of this example, we set '50' as

the density of standard gas we use is

50%LEL.but this setting value can be different

according to the density of your standard gas

4.6

a) Please press [ENT] key to save.

b) When 'YES' is shown,

then Please press [ENT] key.

c) Then, when 'HOL' is shown,

Please press [ENT] key over 3 seconds.

d) When 'END' is shown, span calibration is

completed.

Please remove calibration devices from gas

detectors.

【END】

Page 30: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 32 -

T/S-H2-02

Alarm Tag.: [AIT-1121(1122/1123)_HI] / [AIT-1121(1122/1123)_HH]

Root Cause: Incorrect reading

Trouble Shooting: Calibration of H2 Gas Detector(Model : GTD-2000EX)

1. Procced zero calibration with fresh air.

Touch “FUC” button by using magnetic

pen.

2. Touch “” button.

Then “CALIBRA MODE” will appear.

3. When “CALIBRA MODE appears,

Touch “FUC” button.

4. As touching “FUC”, “ZERO CAL[NO]”

display will be indicated.

5. Then make “ZER CAL[YES]” by touching

“” button.

6. At last, Touch “FUC” button.

【END】

Page 31: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 33 -

T/S-BL-01

Alarm Tag.: [B-117A/B-F] / [B-117A/B-OFF]

Root Cause: Mis-setting of EOCR

Trouble Shooting: Check EOCR setting value

1. Find EOCR inside of motor control cabinet.

2. Check load(A) setting and if setting is

shorter than blower motor capacity,

increase it.

(ex. Motor capacity 4.5A, EOCR setting 5A)

【END】

Page 32: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 34 -

T/S-BS-01

Alarm Tag.: [BST_S_TO_01] / [BST_P_TO_01] / [BSP_S_TO_10] / [BSP_P_TO_10] / [BLR_BOTH_F]

Root Cause: Magnetic Contactor fault

Trouble Shooting: Check the magnetic contactor status

1. Find the matched equipment on MIMIC and

click B-117A/B. Click the MANUAL button.

2. Click the START or RUN button and wait

for the green light on the relevant box.

Need to check the actual status of the equipment.

3. Check magnetic contactor located inside of

motor control cabinet.

If magnetic contactor has defect, replace it.

4. After check, click the STOP button and

wait for the green light on the relevant

box. Then, click the AUTO button.

【END】

Page 33: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 35 -

T/S-CIT-01

Alarm Tag.: [CIT-1111_LO] / [CIT-1111_LL]

Root Cause: Contamination of salinity sensor probe

Trouble Shooting: Clean sensor part

1. Remove the back cover of transmitter.

2. Disconnect cable of transmitter.

3. Disconnect sensor part from the pipe.

4. Clean sensor part with a soft rag.

Caution : Before taking out transmitter, you should disconnect of transmitter at first.

Otherwise, the cable will be severely twisted or be alble to be damaged.

【END】

Page 34: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 36 -

T/S-CIT-02

Alarm Tag.: [CIT-1111_LO] / [CIT-1111_LL]

Root Cause: Incorrect reading

Trouble Shooting: Calibration of salinity sensor

Reference : . We recommend that our customers use 2.5% standard reagent for this manual. However,

in case you don’t have standard reagent, you can use the water from the condensate system with a

known salinity can be used. Or you can make salt-water by using salt and fresh-water.

1. Check the concentration of salt-water

using at calibration

2. Push “menu” button.

3. Push the “select” button for calibration.

4. Push the “select” button for configure

calibration.

Page 35: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 37 -

5. Insert the sensor into the center of

container and wait until the value is stable.

Please be aware that sensor shall not be

shaken. (Hands holding sensor shall not be

trembled.)

6. Push the “yes” button when the value is

stable.

7. Set the salinity value of the seawater

(which checked at STEP1.) by using

and button and push the “enter” button

8. When “SLOPE” display appear, push

“next” button.

Page 36: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 38 -

9. When “OFFSET” display appear, push

“next” button.

10. Remove the sensor from the container and

check the zero value.

11. Insert sensor to the center of container

again and shake the sensor to remove air

during 2 seconds and wait until the value is

stable.

12. Ensure that the value correspond to the

input value at STEP7.

13. If the value is corresponded, the calibration

is over.

14. Push “Next” button if the calibrated value

incorrect.

Page 37: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 39 -

15. Go to “Reset Calibration” mode by using

“Next” button. And push “Select” button.

16. When “RESET?” display appear, push

“yes” button.

17. Calibrated value has been reset and push

the “Next” button.

18. Please perform calibration procedure from

STEP1 to STEP13.

【END】

Page 38: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 40 -

T/S-FIT-01

Alarm Tag.: [FIT-1131(2131)_LO] / [FIT-1131(2131)_LL] /

[FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Incorrect position of the flow control valve

Trouble Shooting: Calibration positioner(Model No.: YT-1000)

1. a) Find the matched valve on MIMIC and

click it.

:b) Click the MANUAL button

2. a) Input “0” on manual set value.

:b) Push Enter button.

:c) Click “COMMAND”.

3. Press “4mA” button located at PCB of

positioner :for five(5) seconds.

4. a) Input “25” on manual set value.

:b) Push Enter button.

:c) Click “COMMAND”.

Page 39: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 41 -

5. Press “8mA” button located at PCB of

positioner :for five(5) seconds.

6. a) Input “50” on manual set value.

:b) Push Enter button.

:c) Click “COMMAND”.

7. Press “12mA” button located at PCB of

positioner for five(5) seconds.

8. a) Input “75” on manual set value.

:b) Push Enter button.

:c) Click “COMMAND”.

Page 40: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 42 -

9. Press “16mA” button located at PCB of

positioner for five(5) seconds.

10. a) Input “100” on manual set value.

:b) Push Enter button.

:c) Click “COMMAND”.

11. Press “20mA” button located at PCB of

positioner for five(5) seconds.

12. In case there is no improvement after

calibration, check signal from PCB.

If output signal is not fit with command,

PCB needs to be replaced.

【END】

Page 41: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 43 -

T/S-FIT-02

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Incorrect position of the flow control valve

Trouble Shooting: Calibration positioner(Model No.: YT-3300 / YT-3300EX)

1. Remove cover bolts.

2. Press the button for six(6) seconds.

3. “AUTO CAL” will appear on display.

Press the button.

4. Then “AUTO 1” will appear on display.

Press “DOWN” button.

5. “AUTO 2” will appear on display. Then

press button.

Calibration will be carried out automatically.

【END】

Page 42: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 44 -

T/S-FIT-03

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Incorrect position of the flow control valve (FCV-1131(2131))

Trouble Shooting: Calibration positioner(Model No.: YT-3400)

1. Press the button for six(6) seconds.

2. “AUTO CAL” will appear on display. Then

press button.

3. “AUTO 1” will appear on display.

Then press “ - “ button.

4. “AUTO 2” will appear on display.

Then press button.

Calibration will be carried out automatically.

【END】

Page 43: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 45 -

T/S-FIT-04

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Incorrect position of the flow control valve (FCV-1131(2131))

Trouble Shooting: Calibration positioner(Model No.: POWER GENEX)

Press “MO”button for five(5) seconds.

Calibration will be carried out automatically.

【END】

Page 44: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 46 -

T/S-FIT-05

Alarm Tag.: [FIT-3211_LO] / [FIT-3211_LL] / [FIT-3211_HI] / [FIT-3211_HH]

Root Cause: Incorrect reading of flow-meter

Trouble Shooting: Calibrate the flow-meter(Model: DTI-200)

1. Make valve line up to do ballasting by using filter by-pass valve.

(Above diagram is for reference)

2. Adjust GS pump flow rate as 130% by using pump in/out pressure transmitter and pump

discharge valve. (Above performance curve is for reference. If GS pump rated capacity is

250m3/h at 85mTH, 130% means 325m3/h at 63mTH.)

Page 45: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 47 -

3. Set the switch of “MODE” as follows on flow-meter local side.

1: ON(Normal), 2: ON(3s), 3: OFF(Limit+Error), 4: OFF(Max)

4. Set the limit value as 100%.

5. Connect ampere meter to flow-meter output and adjust potentiometer slightly to meet 20mA.

Page 46: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 48 -

6. Log in with user account on SERVER

which is placed on ship’s office.

ID : aconis2000 / PW : aconis2000

7. Click point control window icon. And input

TAG FIT-3211.

8. :Check EGU H value.

If value is not matched with 130% flow-

rate(ex. 325m3/hr) which you checked at

procedure No.2 ,change it to value as

130%.

9. Click “ACONIS” mark. Then click

“COMMAND APPLIER”.

Page 47: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 49 -

10. Click check box as above.

11. Click OK.

【END】

Page 48: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 50 -

T/S-FIT-06

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Incorrect setting of flow-meter

Trouble Shooting: Setting correctly(Maker: ABB)

1. Push button to switch to the

information level.

2. Select “Diagnostics” menu by using

or button. Push button to

confirm.

3. Check error message. Then push

button to exit from this page.

4. Push button to switch to the

configuration level.

5. Select “Advanced mode” menu by using

or button. Push button

to confirm.

6. Then “Easy Setup” menu wil appear.

Page 49: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 51 -

7. Push button several times until

“Diagnostics” page appear.

8. Push button until “Empty Pipe

Detector” page appear.

9. Push button. Then Empty pipe

detector on/off page will appear. Check

setting is “off”. If setting is “on”, change to

“off”

10. Push button. Then Empty pipe

detector on/off page will appear. Change to

“off” by using or button.

11. Push button. Then Empty pipe

detector on/off page will appear.

12. Push button until initial page appear.

【END】

Page 50: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 52 -

T/S-FIT-07

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Loosed cable connection

Trouble Shooting: Connect cable

1. Disconnect neck of flow meter. Be careful

that there is cable inside of neck.

2. Check all cable is connected well. If there

is loosed connection, connect it.

【END】

Page 51: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 53 -

T/S-FIT-08

Alarm Tag.: [FIT-1211(2211)_LO] / [FIT-1211(2211)_LL]

Root Cause: Electrode damage

Trouble Shooting: Check resistance(Maker: ABB)

1. Open the glass cover(1). Loose bolts(3)

and pull out the catridge(2).

2. Disconnect cable from PCB.

①Cable for No.1 electrode

②Cable for No.2 electrode

③Cable for earth

3. Check resistance between cables.

a) Normal value is as follows in case water

is located inside of flow-meter.

①~③ : Infinity

②~③ : Infinity

b) In case there is no water in flow-meter,

resistance will detected similarly.

①~③ & ②~③ : similar resistance value.

4. Normal value between ③ and earth

terminal is 0.

5. If the measured value judged abnormal, contact Hyundai Global Service with photo of

measurement.

Hyundai Global Service: [email protected]

BWTS service team leader: [email protected]

【END】

①②③

Earth terminal

Page 52: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 54 -

T/S-LS-01

Alarm Tag.: [LS-1111_LL]

Root Cause: Injection flow fluctuation due to filter back-flushing

Trouble Shooting: If this alarm occurred right after filter’s back-flushing, increase injection flow

control valve’s minimum open ratio.

1. :Check level low alarm is occurred right after

filter’s back-flushing. If back-flushing is

occurred, green light will coming to “Back-

flushing”.

In case filter back-flushing is occurred,

there is a possibility that E.U. injection flow

rate have fluctuation.

It needs to increase flow control valve

minimum open ratio to minimize flow

fluctuation.

2. Go to TRO control setting page.

Increase “FCV MIN” set value by 10%.

(ex. Before 20%, After 30%)

【END】

Page 53: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 55 -

T/S-LS-02

Alarm Tag.: [LS-1141_HI] / [LS-1141_HH]

Root Cause: Contamination of level switch

Trouble Shooting: Clean fork of level switch

1. Disconnect level switch from pipe line.

2. Clean fork with a soft rag.

【END】

Page 54: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 56 -

T/S-TE-01

Alarm Tag.: [TE-1111_HI] / [TE-1111_HH]

Root Cause: Abnormal valve arrangement for heat exchanger

Trouble Shooting: Arrange valve correctly.

1. In case temperature high alarm is

occurred, heat exchanger inlet valve(XV-

1731) to be closed and heat exchanger by-

pass valve to be opened.

In case temperature low alarm is occurred,

heat exchanger inlet valve(XV-1731) to be

closed and heat exchanger by-pass valve to

be opened.

2. If the valve arrangement is wrong, change

correctly.

Click matched valve.

Change to “MANUAL” and arrange

correctly.

3. If the valve position is not changed by

remote, check solenoid valve status of

valve.

4. Turn the auto/manual switch to the auto

mode on the solenoid valve installed in

pneumatic actuator.

【END】

Page 55: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 57 -

T/S-TE-02

Alarm Tag.: [TE-1111_HI] / [TE-1111_HH]

Root Cause: Hot source water temperature is too high

Trouble Shooting: Reduce hot source water flow rate

1. Check hot source temperature. Design

temperature for heat exchanger is 36.

2. If the heat exchanger inlet hot source

temperature is higher than design

temperature, reduce flow-rate by throttling

manual inlet valve.

【END】

Page 56: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 58 -

T/S-FU-01

Alarm Tag.: [FUBV_OP_AL]

Root Cause: Manual open

Trouble Shooting: Close the bypass valve

1. Check solenoid valve status of filter by-

pass valve.

2. Turn the auto/manual switch to the auto

mode on the solenoid valve installed in

pneumatic actuator.

【END】

Page 57: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 59 -

T/S-FU-02

Alarm Tag.: [FUBV_OP_AL]

Root Cause: Incorrect position of limit switch

Trouble Shooting: Check the limit switch if the alarm happens without any operation.

1. Check limit switch position at local.

2. Adjust the stop bolt to rectify the incorrect

position of limit switch.

【END】

Page 58: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 60 -

T/S-FU-03

Alarm Tag.: [BST_S/P_TO_02] / [BSP_S_TO_06] / [DST_S_TO_01] / [DSP_S_TO_04]

Root Cause: Pressure low or fail of the pneumatic supply for the valve

Trouble Shooting: Check if the supply pressure of the pneumatic for the valve is proper.

Recommended pneumatic pressure of the regulator: 5~7kgf/cm2.

1. Check the air pressure for valve actuator is

in range 5~7kgf/cm2.

2. If not, adjust regulator to supply air in range

5~7kgf/cm2.

【END】

Page 59: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 61 -

T/S-FU-04

Alarm Tag.: [BST_S/P_TO_02] / [BSP_S_TO_06] / [DST_S_TO_01] / [DSP_S_TO_04]

Root Cause: Input power fail of the solenoid valve

Trouble Shooting: 1) Check if the input power( DC24V) is properly provided or not.

2) If not, please check the power supply in the control cabinet.

1. Check the input power(DC24V) from the control cabinet and on the solenoid valve of filter

inlet/outlet/bypass valve with multi-meter. The diagram below is for reference only.

Please refer to your vessel’s final drawing.

Page 60: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 62 -

2. Login server no.1 which is located at ship’s office or CCR.

3. Click “P.C.W(Point Control Window)” on the top menu.

4. Input the tag name(‘valve no.-OP (or CL’)) and click “OK”. (ex. BA046-OP)

Page 61: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 63 -

5. Once PCW appear, change the mode to manual.

6. Click “OFF” button, then “OFF” will be changed as “ON”

7. Check the LED of channel(CH) in D.O card which is installed in control cabinet. If the LED is

ON(green color), ACONIS is sending the open (or close) DO command to the valve. But if

not D.O card or ACONIS logic shall be rectified. Above card photo is just example. So

please refer to the electrical wiring diagram which had been delivered to the vessel.

Page 62: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 64 -

8. If valve open(or close) command is given properly, check the valve color(green or not) on

the mimic and valve in local site.

【END】

Page 63: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 65 -

T/S-FU-05

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Back-flushing valve fail

Trouble Shooting:

1) Check if the back-flushing valve is working or not by pressing the TEST button on

the Filter local panel.

2) If not, please check the supply air and its pressure, 5~7kgf/cm2, is proper or not.

3) Check the solenoid valve and control signal.

1. Check if the back-flushing valve is working

or not by pressing the TEST button on the

Filter local panel.

2. If backflushing valve is not working well,

please check the supply air and its

pressure, 5~7kgf/cm2, is proper or not.

If pressure is low please regulate the

pressure with 5~7kgf/cm2.

3. a) Rotate this point clockwise and check

movement of the valves

b) If the movement of valves doesn't

change even though you rotate it

Clockwise or counterclockwise, you can

suspect the air-line condition or clogging

of the pneumatic solenoid valve. In that

case, you can try to clean it.

c) Please remember that ship’s crew shall

restore this point back again(Remote

mode)

【END】

Page 64: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 66 -

T/S-FU-06

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Back-flushing motor fault

Trouble Shooting:

1) Check if the MCCB for motor is “OFF” in the Filter Panel. If “OFF”, please turn it

“ON”.

2) Check if the error lamp of KM1 contactor is on or not inside LCP after reset. If

error keeps on, please check if there is any foreign body interrupting rotation of the

back-flushing arm inside of the filter unit

3) Check the geared motor.

1. a) Turn on the main switch on the LCP door..

:b) Open the LCP door and find out Q1 switch and KM1 contactor.

2. a) Check if the Q1 switch is on(it shall be

on).

b) If Q1 switch is on, reset the KM1

contactor

3. How to reset KM1 :

a) Open the transperent plastic cover of

KM contactor

b) Check if the “Err” lamp is on(red color).

c) If “Err” lamp is on press the reset button

for 2~3 senconds.

Page 65: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 67 -

4. Check gear motor

a) Check the cable connection of motor terminal box.

b) Check the rotation direction of motor referring to the direction mark.

c) Check the output power of motor and restart motor after cooling. If motor output is lower

than the specification it may cause unstable backflushing function. It needs to be replaced

with rated capacity.

d) If above all is fine but it keeps on diffierential alarm, filter is clogging with internal particles.

It shall be required to clean the filter element.

【END】

Page 66: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 68 -

T/S-FU-07

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Blockage of the air vent

Trouble Shooting: Check if the air vent valve is open.

Check the valve is blocked.

1. Check if the air vent valve is open.

2. If not, please open the valve and check if

inside hole is blocked or not.

3. If air vent blocked, please remove a

foreign blocking material.

【END】

Page 67: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 69 -

T/S-FU-08

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Pressure sensor fail

Trouble Shooting: 1) Check if the inlet/outlet pressure sensors is working properly.

2) If not, please check the cable and signal.

1. Check Press. Sensor

a) Check the plug and wiring.

b) Check pressure value in the mimic

displayed.

c) If plug and wiring is right but the each

pressure value is not changed during

operation or back flushing, it is required

to be cleaned.

2. The procedure befor cleaning

a) To clean or replace with new pressure transmitter sensor open the drain valve and

drain out the seawater

b) Turn off the main switch on the LCP to power off.

Page 68: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 70 -

3. How to clean pressure transmitter

a) Remove sensor connector, disassemble the sensor using the spanner and clean sensor

part.

b) Close the drain valve and turn on the main switch on the LCP.

Caution : PIT Sensor is very sensetive. Therefore, please don’t use compressed air to clean.

Especially, please don’t poke detecting hole by sharpen tool.

4. Replace the pressure transmitter

- After cleaning the pressure transmitter, if indicated pressure is not proper or isn’t changed,

please replace it with a new one

【END】

Detecting Hole

Page 69: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 71 -

T/S-FU-09

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Clogging of the filter elements

Trouble Shooting: Do back-flushing with ballast pump.

1. Arrangement

:a) Arrange the valves to sea to sea mode

b) Open Sea chest valve, filter in/out valve, FCV-1211(35%) or FCV-2211(35%), Overboard

valve

2. Manual Backflushing

a) Start ballast pump without BWTS system.

b) Click “M” button and press “FLUSHING START” as like the above mimic to do back-

flushing

c) Back flushing will stop automatically after 30 seconds

d) Press “FLUSHING START” button every 30s for 5min to remove the particles stuck on

the filter element.

e) If the DP is still high, element of filter should be checked

【END】

Page 70: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 72 -

T/S-FU-10

Alarm Tag.: [FU_DP_HH] / [FU_DP_HI]

Root Cause: Clogging of the filter elements

Trouble Shooting:

1) Check the filter elements are contaminated or not. If then, please do cleaning

according to the cleaning procedure.

2) It might be possible due to heavy duty over than rated flow capacity or heavy

load including muddy and sand. In case of heavy duty, please reduce the rated flow

capacity until back-flushing becomes normal, for instance, 50% of the rated flow

capacity.

1. The procedure befor cleaning

a) Open the drain valve and drain out the seawater

b) Turn off the main switch on the LCP to power off.

2. Untie earth wire on the cover plate.

Page 71: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 73 -

3. Untie earth wire on the lower part.

4. If the motor is not ATEX(not exproof-type) remove motor & sensor cable

5. If the motor is ATEX(Exproof-type), open the motor cover and untie the cable.

Page 72: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 74 -

6. Use the chain block and sling belt to lift the center point of the cover plate

Caution: Lift the belt alongside the center line of the cover plate to make it easy to assemble.

7. a) Loosen the bolts on the cover plate

b) Arrange the bolts & nuts for the prevention of the loss

Page 73: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 75 -

8. a) Lift the top cover plate over the 700 mm.

b) Loosen the tefron washer using the 19mm box wrench and arrange the washer in the box

to prevent the loss

9. a) Take out the upper mounting plate

b) Pull out the element and check the rubber sealing of the element.

Page 74: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 76 -

10. a) Clean the filter elements from outside to inside using the high pressure machine.

b) Start the cleaning of the element at a distance of the water jet about 1m

c) Slowly reduce the distance about 50cm

d) The Maximum water temperature should not exceed 60

e) The pressure range of the water jet should be ‘20bar<P<100bar’

(Only Fresh Water can be used)

11. Put the filter element back inside after cleaning.

:Push the element down strongly but if it is hard to insert ship’s crew can use the rubber

hammer.

Page 75: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 77 -

12. a) Put the upper mounting plate on the filter element.

b) Tighten up tefron washer using box wrench carefully. Don’t tighten strongly, it could be

borken up.

13. a) Adjust the horizontality between the housing flange and tefron washer.

b) Match the lock-pin and lock-hole

c) Match the drive shaft and intermediate shaft.

d) Put the top cover.

14. a) Assemble the bolt & nut by the hand of ship’s crew temporarily.

b) Tighten up by air impact according to the number of the left picture(repeat 2~3 times).

c) Turn along the circle(2~3 times).

Page 76: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 78 -

15. a) Reconnect the motor & earth cables

b) Close the drain valve.

c) Turn on the main switch on the LCP to power on.

【END】

Page 77: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 79 -

T/S-FU-11

Alarm Tag.: [F-121(122)-F]

Root Cause: Power switch off or circuit abnormal, etc,.

Trouble Shooting: Check the power switch or circuit in LCP

1. Please check whether the power switch on LCP is on or not, if switch is off, please turn on

the switch.

2. a) Please check the below condition when the LCP power is on

b) Disconnect the wire from the X1 terminal block no.1, 3(white color cable)

c) Check the terminal block no. 1, 3 by the multimeter with buzzer.

(connect the test probe to no.1,3 terminal block)

d) If multimeter buzzer is on, LCP has no problem, but if not, it need to replace the K3

relay K3 relay.

e) When the multimeter buzzer is on, turn off the Q1 switch. Then the multimeter buzzer will

be off. The LCP has no problem.

Page 78: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 80 -

3. The no.1 lamp led of the PLC will be on when turn off the Q1 switch. If yes, the filter LCP has

no problem and it need to check other components, not filter LCP.

4. Press “ESC” button 2times and the text display will be shown. And press “ ENTER” button

then if “NO ALARMS ACTIVE” is shown on the display, it means normal condition of the filter.

【END】

Page 79: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 81 -

T/S-FU-12

Alarm Tag.: [F-121(122)-F]

Root Cause: CPU in stop mode alarm

Trouble Shooting: EEPROM upgrade is required

1. Turn off the main switch of LCP.

2. : Pull out the cover (EEPROM connection

cover).

3. a) Install the new version EEPROM to the EEPROM connection port

EEPROM will be supplied by Hydac filter supplier.

b) Turn on the main switch of LCP.

Page 80: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 82 -

4. a) The text display shows like above photo (It will take only seconds)

b) Then turn off the main switch again

c) Remove the EEPROM, install the cover.

d) Turn on the main switch for checking and text display will show like photo below again.

It will take only few seconds after turning on the main switch.

5. If the message “ CPU stom in mode” shows on the display screen again after updating new

version. Change the PLC mode ” RUN→STOP→RUN”

6. a) Check the program version after upgrading the program

b) Push the “” button 2times. Then the display will show the program version.

(See below photo)

【END】

Page 81: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 83 -

T/S-FU-13

Alarm Tag.: [F-121(122)-F]

Root Cause: CPU not responding

Trouble Shooting: Change the baud rate

1. a) If the display shows “CPU NOT RESPONDING” message after updating program,

push the “ESC” button

b) Choice the “DIAGNOSTIC MENU” and push the “ENTER” button.

c) Choice the “BAUD RATE” and push the “ENTER” button.

d) Choice the “ TD 200 SETUP” and push the “ENTER” button.

Page 82: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 84 -

2. a) Change the baud rate to 19.2K like above photo no.1

Normally the default value is 19.2K.

b) Then push “ESC” button and display will show filter condition like No.4 photo.

c) But if display shows “CPU NOT RESPONDING” message again please try to change

baud rate like above photo no.2 & 3.

【END】

No.4

Page 83: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 85 -

T/S-FU-14

Alarm Tag.: [F-121/221-RDY]

Root Cause: MCCB “OFF”

Trouble Shooting: Check if the MCCB of filter is” OFF” or not. If “OFF”, please turn it on.

1. Check if the MCCB of filter is OFF or not. If OFF, please turn it on.

【END】

Page 84: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 86 -

T/S-TRO-01

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause:

No water flow(Local message : WATR)

Intake water flow too fast(Local message : FAST)

Intake water flow too slow(Local message : SLOW)

Trouble Shooting: Adjust intake flow rate

This trouble shooting to be checked during ballasting or de-ballasting operation.

1. Press service button.

2. Wait until “HOLd” is displayed. Then, press

the MODE button.

3. Press or button.

4. It will display one of three messages. HI,

GOOD or LO

Page 85: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 87 -

4. If message is “HI”, please turn regulating valve to

counter clock-wise(1/4 turn).

5. If message is “LO”, please turn regulating vale to

clock-wise(1/4 turn).

Conduct 1~5 until message come to “GOOD”.

7. To return to normal operation, press button.

【END】

Page 86: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 88 -

T/S-TRO-02

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: Expired reagent life time or no reagent

Trouble Shooting: Replace reagent(Buffer, Indicator)

1. Check reagent expiration date and replacement interval.

Buffer solution to be replaced every 1 year.

Indicator & DPD powder mixture to be replaced every

90 days.

2. Remove the cap of small liquid indicator

reagent and add the contents of DPD

powder bottle.

3. Cap and shake it to fully dissolve the

powder.

Buffer

DPD Powder

Indicator

Page 87: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 89 -

3. Find buffer and indicator bottle in TRO sensor.

Remove cap from each bottle and change with new one.

4. Press SERVICE button.

5. Press PRIME button. Then press

button.

【END】

5

Page 88: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 90 -

T/S-TRO-03

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: Check valve clogging

Trouble Shooting: Clean check valve

1. Press service button.

2. Then “HOLd” is displayed.

3. Remove cap from buffer and indicator bottle.

4. Prepare flushing kit (supplied as spare/tool parts).

Draw back syringe plunger to fill fresh-water.

Page 89: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 91 -

5. Insert end of syringe to end of each tubing. And push plunger to clean tubing and check

valve. Repeat 2~3 times. Check smooth water flow through tubing.

6. Re-assemble cap of each bottle.

7. Press SERVICE button.

8. Press PRIME button. Then press

button.

【END】

Page 90: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 92 -

T/S-TRO-04

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: Dirty cuvette(Local message : GLAS)

Trouble Shooting: Clean cuvette

1. Press service button.

2. Turn the knurled top on the optics system

counterclockwise until the cuvette just pops

out.

(But do not remove the top)

3. Move the retaining o-ring and push the

cuvette. The cuvette just pops out.

4. Remove the cuvette.

Clean the cuvette with dry cloth and

install again.

5. Turn the knurled top clockwise until the cuvette

is held securely.

Page 91: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 93 -

6. Press SERVICE button.

7. Press PRIME button.

Then press button.

【END】

Page 92: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 94 -

T/S-TRO-05

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: No water flow(Local message : WATR)

Trouble Shooting: Clean intake solenoid valve

1. Loose bolts which secure coil and valve

body.

2. Then plunger will be come out.

3. You can find plunger, spring and steel plate. Clean them.

4. Reassemble in reverse order of disassembly.

【END】

Page 93: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 95 -

T/S-TRO-06

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: Sample cuvette is not purged(Local Message : NPRG)

Trouble Shooting: Check drain line of TRO sensor

1. Press service button. This function will

drain the water inside cuvette.

2. Check sample water is drained properly

through drain tube.

3. At the same time, check the purge

solenoid vlave operating lamp “ON” status.

4. If purge solenoid valve is not turned “ON”

and remain “OFF” condition, check cable

connection.

5. In case abnormal is still persist, replace

the purge solenoid valve.

6. There is possibility that drain pipe which

connected with TRO sensor is clogged.

Check drain pipe status from TRO sensor

to bilge well(or independent drain tank)

【END】

Page 94: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 96 -

T/S-TRO-07

Alarm Tag.: [TRO_LL] / [TRO_LO]

Root Cause: Analog output signal is abnormal(Local Message : MA)

Trouble Shooting: Check TRO sensor’s analog output(4-20mA)

1. Press “MODE/EXIT” button.

2. 4-20mA ON/OFF page will appear. If

setting is “OFF”, change to “ON” by

pushing “” or”” button.

3. Press button until “EXTD” display is

appeared. If the setting is “OFF”, change to

“ON” by pushing “”or”” button.

4. Press button until display showing

4MA.

5. Prepare multi-meter for signal

measurement.

6. Connect multi-meter to “+” and “-“ terminal.

Page 95: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 97 -

7. If multi-meter does not indicate 4.00mA, please adjust signal by pushing “”or”” button.

8. Press button until display showing

20MA.

Page 96: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 98 -

9. If multi-meter does not indicate 20.00mA, please adjust signal by pushing “”or”” button.

10. Press button until display showing

MG/L.

【END】

Page 97: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 99 -

T/S-TRO-08

Alarm Tag.: [TRO_HI] / [TRO_HH] for ballasting

Root Cause: High current of rectifier

Trouble Shooting: Adjust rectifier current set value

1. In case [TRO_HI] or [TRO_HH] alarm activated within few minutes after ballasting operation,

please reduce initial current set value by 10A.(e.g. before : 500A, after : 490A)

Page 98: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 100 -

2. In case [TRO_HI] or [TRO_HH] alarm activated during ballasting operation,

please increase step current reduction value. (e.g. before : 2A, after : 4A)

【END】

Page 99: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 101 -

T/S-TRO-09

Alarm Tag.: [TRO_HI] / [TRO_HH] for de-ballasting

Root Cause: Solenoid valve clogging

Trouble Shooting: Clean solenoid valve

1. Disconnect N.U. solenoid valve from

discharge line.

2. Loose upper nut which secure core tube.

3. Remove O-ring from valve body.

4. Separate core tube from valve body by

using spanner.

5. Separate plunger from core tube.

6. Clean core tub, plunger and spring.

Page 100: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 102 -

7. Reassemble in reverse order of

disassembly.

【END】

Page 101: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 103 -

T/S-TRO-10

Alarm Tag.: [TRO_HI] / [TRO_HH] for de-ballasting

Root Cause: Mis-arrangement of manual valve

Trouble Shooting: Arrange manual valve correctly

1. Arrange manual valve correctly.(below diagram is reference only)

【END】

Page 102: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 104 -

T/S-TRO-11

Alarm Tag.: [TRO_HI] / [TRO_HH] for de-ballasting

Root Cause: Mis-setting of N.U. pump stroke dial

Trouble Shooting: Set N.U. pump stroke dial as 100%

1. Check N.U. pump stroke dial is set as

100%.

2. Loose dial shaft setting bolt.

3. Set main scale as 100%. Then fix dial

fastening bolt.

【END】

Page 103: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 105 -

T/S-NU-01

Alarm Tag.: [LIT-1311_LO] / [LIT-1311_LL]

Root Cause: Malfunction of level transmitter

Trouble Shooting: Calibrate level transmitter

1. Disconnect level transmitter from flange.

2. Raise two floaters to the top end

(B point)

3. Check value of local display and output

signal.

If display value over 100%, refer to No.3-1.

If output signal over 20mA, refer to No.3-2.

If display value less than 100%, refer to No.3-3.

If output signal less than 20mA, refer to No.3-4.

3-1. (Both floats position to be in B point)

Turn “SPAN3” counterclockwise slowly. If display indicates 100%, stop turning of “SPAN3”

Top end(B point)

Bottom end(A point)

Page 104: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 106 -

3-2. (Both floats position to be in B point)

Turn “SPAN1” counterclockwise slowly. If output signal indicates 20mA, stop turning of

“SPAN1”

3-3. (Both floats position to be in B point)

Turn “SPAN3” clockwise slowly. If display indicates 100%, stop turning of “SPAN3”

Page 105: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 107 -

3-4. (Both floats position to be in B point)

Turn “SPAN1” clockwise slowly. If output signal indicates 20mA, stop turning of “SPAN1”

4. Take down two floaters to the bottom

end (A point).

5. Check BWTS model. Then check minimum

display(%) and output(mA) value on above

table.

BWTS

Model

A point B point

Min.

Display

(%)

Min.

Output

(mA)

Max.

Display

(%)

Max.

Output

(mA)

HiB-1000 10.5% 5.68mA 100% 20mA

HiB-2000 14.9% 6.38mA 100% 20mA

HiB-3000 11.8% 5.88mA 100% 20mA

HiB-4000 11.8% 5.88A 100% 20mA

HiB-5000 10.7% 5.71mA 100% 20mA

HiB-6000 10.7% 5.71mA 100% 20mA

6. Check value of local display and output

signal.

If display value over minimum display value,

refer to No.5-1.

If output signal over minimum output value,

refer to No.5-2.

If display value less than minimum display

value, refer to No.5-3.

If output signal less than minimum output

value, refer to No.5-4.

Top end(B point)

Bottom end(A point)

Page 106: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 108 -

6-1. (Both floats position to be in A point)

Turn “ZERO3” counterclockwise slowly. If output signal indicates minimum display value,

stop turning of “ZERO3”

6-2. (Both floats position to be in A point)

Turn “ZERO1” counterclockwise slowly. If output signal indicates minimum output value,

stop turning of “ZERO1”

Page 107: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 109 -

6-3. (Both floats position to be in A point)

Turn “ZERO3” clockwise slowly. If output signal indicates minimum display value,

stop turning of “ZERO3”

6-4. (Both floats position to be in A point)

Turn “ZERO1” clockwise slowly. If output signal indicates minimum output value,

stop turning of “ZERO1”

【END】

Page 108: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 110 -

T/S-NU-02

Alarm Tag.: [LIT-1311_LO] / [LIT-1311_LL]

Root Cause: Leakage on N.U. tank

Trouble Shooting: Repair N.U. tank

1. Prepare tool material and tool. ①PE bar

②Drill(small) ③Torch ④Grinder

⑤Drill(big)

2. Grind crack part.

3. Make V groove by using grinder.

4. Make small hole at the end of the crack

to prevent extension of crack.

Page 109: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 111 -

5. Weld crack part by using torch and PE bar.

6. Make flat face by using grinder.

7. Reinforce welded part.

8. Completed

【END】

Page 110: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 112 -

T/S-NU-03

Alarm Tag.: [LIT-1311_LO] / [LIT-1311_LL]

Root Cause: Damage of float

Trouble Shooting: Replace float

1. Check float condition. If damaged, replace it.

【END】

Page 111: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 113 -

T/S-NU-04

Alarm Tag.: P-132(232/332)-TRIP

Root Cause: No power supply, fuse damage

Trouble Shooting: Check power supply

Check fuse condition and replace it, if needed.

1. Unscrew cover bolts.

2. Unscrew inner bolts.

3. Check source of electric power

(AC 380~480V).

4. If power source is not coming, check MCCB

status.

5. If power source is coming normally, check

fuse status. In case LED is off condition,

fuses need to be replaced.

【END】

Page 112: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 114 -

T/S-NU-05

Alarm Tag.: P-132(232/332)-TRIP

Root Cause: Short circuit

Trouble Shooting: Check insulation resistance

1. Unscrew cover bolts.

2. Unscrew inner bolts.

3. You can find power terminal.

4. Operate the test by short-circuiting the

power terminal as shown in below picture

by using 500V insulation resistance

tester.(Criteria over 100MΩ)

5. If the measured value judged abnormal, contact Hyundai Global Service with photo of

measurement.

【END】

Page 113: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 115 -

T/S-NU-06

Alarm Tag.: [NUPD_S(P/AP)_TO] / [ NUPS_TO] /

[NUPD_S(P/AP)_SP_TO] / [ NUPS_SP_TO]

Root Cause: Wrong mode setting

Trouble Shooting: Check REMOTE/AUTO mode

1. Check led on “REMOTE/AUTO” mode.

If pump is “LOCAL/MANUAL” mode,

change the mode to “REMOTE/AUTO”.

【END】

Page 114: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 116 -

T/S-REC-01

Alarm Tag.: [R1(2/3)_COMM_ERR]

Root Cause: Cable connection fault

Trouble Shooting: Check cable connection

1. Check RS-485 cable connection is correct. This terminal is located at bottom of rectifier.

【END】

Page 115: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 117 -

T/S-REC-02

Alarm Tag.: [R1(2/3)_COMM_ERR]

Root Cause: Wrong operation mode selection

Trouble Shooting: Check operation mode to “AUTO/REMOTE”

1. Check rectifier is set to “AUTO” on MIMIC.

If not, change to “AUTO”.

2. Check rectifier is set to “REMOTE” on local

panel. If not, change to “REMOTE”.

【END】

Page 116: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 118 -

T/S-REC-03

Alarm Tag.: [R1(2/3)_COMM_ERR]

Root Cause: PCB malfunction

Trouble Shooting: Check “ID selection” and LED status on PCB.

1. Unscrew cover bolts.

2. Check “ID SELECTION” dial is set

correctly.

RF-142A : DIAL 1

RF-142B : DIAL 2

RF-142C : DIAL 3

RF-142D : DIAL 4

3. ::Check RXD/TXD LED status on PCB.

Normally RXD and TXD LED to be blinkled

altenately.

If the LED status is abnormal,

contact Hyundai Global Service with

relevant photo.

【END】

Page 117: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 119 -

T/S-REC-04

Alarm Tag.: [R1(2/3)_COMM_ERR]

Root Cause: HiSCM card malfunction

Trouble Shooting: Check LED status of HiSCM card

1. Check LED status of HiSCM card.

2. HiSCM card has 8 channels for interfacing

with 3rd party system. Recitifers are

connected with each channelr. Below

photo is just for reference.

Please find channel information from final

drawing.

3. If LED Status of channel is OFF or Steady

(not flickering), reset HiSCM according to

procedure No.4.

If LED flickered with Green color, HiSCM is

in normal status but data is not coming

from rectifier.

In this case please investigate rectifier

side.

If LED flickered with Blue color,

communication is working well with

rectifier.

Page 118: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 120 -

4. Push side button of HiSCM card

5. Pull HiSCM card out.

6. Mount securely again.

【END】

Page 119: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 121 -

T/S-REC-05

Alarm Tag.: [REC1(2/3/4)002]

Root Cause: External emergency stop

Trouble Shooting: Reset rectifier

1. External emergnecy stop(Error code A16)

is come from outside of rectifier.

Remove emergency stop condition first,

then reset rectifier.

2. Click Reset button on rectifier MIMIC.

Page 120: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 122 -

3. Click Reset button on MIMIC.

【END】

Page 121: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 123 -

T/S-REC-06

Alarm Tag.: [RF-A/B/C/D-1007]

Root Cause: Loosen of output cable connection, PCB malfunction

Trouble Shooting: Check output cable, compare actual value and MIMIC value

1. Check power cable connection. If loosed,

tighten it.(Before tightening, cut the power.)

2. During ballasting operation, check actual

shunt value by using clamp meter.

3. Check MIMIC value on HMI.(Shunt #1,#2,#3 and #4)

Page 122: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 124 -

4. Check shtun valve on MIMIC.

5. If there is big devaition between local and

MIMIC, PCB need to be replaced.

【END】

Page 123: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 125 -

T/S-REC-07

Alarm Tag.: [RF-A/B/C/D-1007]

Root Cause: Loosen of power feeder cable

Trouble Shooting: Check cable tightness of the power feeder.

1. Before cable connection check,

:cut the rectifier power.

2. If there is loosed connection, tight it.

【END】

Page 124: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 126 -

T/S-REC-08

Alarm Tag.: [RF-A/B/C/D-1007]

Root Cause: Mis-arrangement of manual valve.

Trouble Shooting: Check the manual valve of electrolyzer outlet is open.

1. Check electrolyzer outlet valve is open.

(Default open)

【END】

Page 125: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 127 -

T/S-REC-09

Alarm Tag.: [RF-A(/B/C/D)-1004] / [REC-1(2/3/4)004] /

[RF-A(/B/C/D)-1007] / [REC-1(2/3/4)007]

Root Cause: Electrolyzer scale formation

Trouble Shooting: Acid cleaning of electrolyzer

1. Preparation

1) Circulation pump(Flow-rate 20m3/hr)

2) 200L Drum

3) Acid Chemical(Prepare one of below

chemical)

HCl(Hydrochloric Acid) 1% density

SAF-ACID 7% density

DESCALEX 4% density

4) Hose, Flange fitting

2. Drain electrolyzer unit by opening drain

valve(Tag No. DV-1111, DV-1121)

3. Close electrolyzer inlet valve(Tag No. XV-1121) and outlet valve(Tag No. MV-1111) to isolate.

MV-1111

XV-1121

Page 126: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 128 -

4. For cleaning module A, please close outlet valve of module B (Tag no. : MV-1113B) and C

(Tag no. : MV-1113C).

If you want clean module B, close outlet valve of module A (Tag no. : MV-1113A) and C (Tag

no. : MV-1113C).

5. Prepare 200L drum and dilute Acid

chemical with fresh-water.

HCl(Hydrochloric Acid) 1% density

SAF-ACID 7% density

DESCALEX 4% density

MV-1113C MV-1113B MV-1113A

Page 127: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 129 -

6. Prepare circulation pump and hose, connect to maintenance flange like below.

Page 128: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

- 130 -

7. Circulate the acid solution by using

cirulation pump for 2hours. And then check

pH. If pH is above 2, add 25%(vol.) of the

acid initial filling more.

8. Repeat step 7 two times more.

(Total acid cleaning time : 6 hours)

9. After cleaning, drain acid solution totally.

Then rinsing by fresh water circulation.

10. Arrange valve for normal operation.(Open

electrolyzer outlet valve and inlet valve.

Close drain valve)

【END】

Page 129: Service Lettereas.hhishipas.com/attach/2018/09/5051764501.pdf · Service Letter Date : Sep 20, 2018 Ref. No.: HGS-BWTS-SL-18-0001 Subject : Trouble Shooting Manual Type : HiBallast

Head office

Centum Science Park, 79, Centum Jungang-ro,

Haeundae-gu, Busan 48058, Rep. of Korea

Tel +82 52 204 7600~1, Fax +82 52 204 7700

https://www.hyundai-gs.com

Technical Division

Tel +82 52 204 7852

E-mail [email protected]

Green Service Team

Tel +82 52 204 7630

E-mail [email protected]