SERVICE DATA SHEET 242288302 ICE & WATER - AUTOMATIC DEFROST SIDE BY SIDE - R134a CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. Diagnostic Mode Activate: Press ^ and V temperature pads for up to 10 sec. simultaneously. Press + to advance through tests. Deactivate: Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. • Tests marked with “*” may not be applicable to this unit and will not be displayed in Diagnostic Mode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. Test To activate test: Passing result -- First Screen -- All LED lights on UI illuminated -- Second Screen -- All segments on UI temperature displays illuminated -- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+” blinking on FF display side to show location. 28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released 1* Standard Compressor and Condenser Fan Press set Compressor and Condenser Fan running when “on”; stopped when “off” 2 Defrost Heater Press set Defrost limit switch must be closed; verify “CL” in test 26. Feel for heat from defrost heater when “on”. If “OP” in test 26, heater will not activate. 3 FF Light Press set With FF door open, FF lights on when “on”; off when “off” 8 Water Valve (Dispenser) Press set Be prepared to collect water at dispenser. Water dispenses when “on”; stops when “off” 9 FZ Light Press set With FZ door open, FZ lights on when “on”, off when “off” 10 Auger Motor Press set FZ door must be closed. Motor running when “on”; motor stopped when “off” 11 Cube/Crush Solenoid Press set Do not leave solenoid in activated state. Solenoid activated when “on”; deactivated when “off” 41* Perfect Temp Drawer (PTD) Press set PTD UI illuminated when “on”, off when “off” 12* VCC Condenser Fan Press set Fan running when “on”; stopped when “off” 38* VCC Compressor Press set Compressor running when “on”; stopped when “off” 15 Evaporator Fan Press set Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when “off”. Feedback failure if fan starts but runs less than 10 sec. Listen for speed change from “LO” to “HI”. 22 Damper Press set With inspection mirror, observe damper open when “OP”; closed when “CL” 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open 26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open 36 Ice Chute Door Depress ice chute door or press set “OP” on UI when manually opened; “CL” when closed. Or, using “set”, “OP” on UI when fully opened or "CL" when fully closed by the motor. 29 FF Thermistor Mid-level Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at mid-level FF thermistor location. “OP-” if open; “SH-” if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location. “OP” if open; “SH” if short 33 Ambient Thermistor @ Main Board Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short 35 FF Thermistor Upper-Level Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F of temperature measured with gauge at upper-level FF thermistor location. “OP¯” if open; “SH¯” if short 34 Ambient Thermistor @ UI Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem- perature measured with gauge at UI location. “OP” if open; “SH” if short 46 Humidity Sensor Activates automatically “OP” if open, “SH” if short AC Heater System: Displays %RH DC Heater System: “HI” – heater should be on “Lo” – heater should be off %RH is displayed when humidity is between “Lo” and “HI” values; heater could be on or off. 47* Dispenser Pocket Heater Press set AC Heater System: “--” ; test not available DC Heater System: heater on when “on”, off when “off” 0- Firmware Parameters Press set Displays digit sequence; record 2- Main Board Firmware Press set Displays digit sequence; record 4- UI Firmware Press set Displays digit sequence; record Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows: Replace Inverter Check at the connector from main control into the inverter (typically BLK and RED wires) Is Inverter receiving 10-15 VAC and 1-5 VDC from Main Control? Check at Main Control Board (BLK/WHT and RED/BLK wires) Is Main Control sending 10-15 VAC and 1-5 VDC to Inverter? no Check at the connector from the service cord into the inverter (typically PUR and WHT wires.) Is Inverter receiving 115 VAC from power supply? yes Check voltage supply. Check and repair service cord wiring and connections. no Identify and repair damaged wires or poor connections between Main Control and Inverter yes Remove inverter box from the compressor and check resistance across compressor winding pairs as shown. Is resistance across all winding pairs equal? yes Replace Compressor no Check connections from Inverter to Compressor Are connections from Inverter to Compressor intact? yes yes Identify and repair damaged wires or poor connections between Inverter and Compressor. no VCC Resistance Check Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. Replace Main Control no PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 0° F FREEZER & 37° F FRESH FOOD (2500 ++ V5) Type A with Run/ Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Variable Speed Standard Variable Speed Standard Operating Time 74 to 84% 32 to 40% 100% 55 to 65% Freezer Temperature -2° to 2° F -19° to -17° C 0° to 4° F -18° to -16° C -1° to 3° F -18° to -16° C -1° to 3° F -18° to -16° C Refrigerator Temperature 34° to 39° F 1° to 4° C 34° to 39° F 1° to 4° C 34° to 39° F 1° to 4° C 34° to 39° F 1° to 4° C Low Side Pressure (cut-in) 5 to 12 psig 43 to 83 kPa 5 to 12 psig 43 to 83 kPa N/A 5 to 12 psig 43 to 83 kPa Low Side Pressure (cut-out) -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa -2 to 2 psig -14 to 14 kPa High Side Pressure (last 1 / 3 cycle) 90 to 105 psig 621 to 724 kPa 90 to 115 psig 621 to 793 kPa 120 to 135 psig 827 to 931 kPa 130 to 155 psig 896 to 1069 kPa Wattage (last 1 / 3 cycle) 50 to 60 90 to 130 60 to 70 100 to 140 Amps (running) 0.5 to 0.9 0.7 to 1.1 0.6 to 1.0 0.8 to 1.2 Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS Cabinet Size Thermostat Heater Cut-in Cut-out Watts Ohms 23’ CD, 26’ 25° F (-4° C) 47° F (8° C) 450 30 Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running OUT 1A OUT 2A OUT 1B OUT 1B ERF-2500++ V5 REFRIGERATOR CONTROL NTC 1 - FF NTC 2 - FF NTC - FZ DEFROST HEATER DEFROST THERM. NEUTRAL CONTROL GROUND ICE FLAPPER SOLENOID +5V +5V +5V DC EVAPORATOR FAN M DAMPER MOTOR M FG VCC(+12) COM VS VCC COMPRESSOR CONDENSER FAN STANDARD COMPRESSOR M COMMON HIGH LINE AMBIENT NTC DEFROST SENSE LINE G5LE RELAY LIN E NEUTRAL AUGER MOTOR LINE CUBE/CRUSHED ICE GATE CONTROL M DOOR SWITCH NEUTRAL LINE LINE J3-16 J3-3 J3-3 J3- 7 DISPENSER VALVE PRIMARY VALVE ICE MAKER FILL VALV E ICE MAKER FILL SWITCH G8P RELAY J4-B1-6 J4-B1-1 J4-B1-2 J4-B1-3 J4-A1-9 J4-A1-3 J4-A1-10 J4-A1-4 J4-A1-11 J4-A1-5 J2- 1 J3- 2 J3-1 J2-2 J1-4 J4-B1-4 J4-A1-6 J4-A1-7 J4-B1-5 J4-A1-13 J4-A1-14 J8- 5 J8- 6 J8- 7 J8- 8 JF- 1 JF- 2 JF- 3 JF- 4 ASSY_OUT ASSY_IN +5V GROUND +5V RESET_FLASH BKGD/MSJ GROUND J9A-1 J9A-2 J9A-3 VEE (+12V) COMM GROUND ISOLATED USER INTERFACE J1-1 J2-9 J2-10 J3-13 J3-14 J3-15 J3-16 J1-3 J2-7 NEUTRAL (SERVICE CORD) NEUTRAL (CONDENSER FAN) NEUTRAL (WATER VALVE 1) NEUTRAL (NOT USED) NEUTRAL (COMPRESSOR) NEUTRAL (LED POWER SUPPLY) NEUTRAL (DISPENSER & ICE MAKER VALVE) LINE (SERVICE CORD ) LINE (Vcc COMPRESSOR) J6 -1 J6-2 J6-3 J6-4 J6-5 J6-6 J6-7 J6-8 ICE MAKER FAN POWER TWIST TRAY MOTOR DIRECTION 1 TWIST TRAY SWITCH NTC POWER ICE MAKER FAN GROUND TWIST TRAY MOTOR DIRECTION 2 TWIST TRAY SWITCH NTC FEEBACK TWIST ICE MAKER ICE & WATER DISPENSER CONTROL OPTIONAL LED POWER BOARD J3- 1 J3- 4 J3- 3 NEUTRAL FREEZER LIGHT S REFRIGERATOR LIGHTS FZR DOOR SW. SENSE J3-9 J3-10 J2-12 J3-8 J3-11 J2-6 LINE FF DOOR SW. SENSE Error Codes Special Modes Display Interpretation Mode Display Activate/Deactivate (press for up to 10 sec. simultaneously) FZ FF FZ FF -- OP- Open FF mid-level thermistor Manual Defrost d F + and -/same to deactivate -- OP¯ Open FF upper-level thermistor Display/ Showroom 77 77 ^ and -/set OP -- Open FZ thermistor Sabbath Sb Sb V and +/same to deactivate -- SH- Shorted FF mid-level thermistor Diagnostic No FF or FZ display, all UI LEDs on. ^ and V/+ to deactivate -- SH¯ Shorted FF upper-level thermistor Notes: • Always check for pin back-outs, pinched or damaged wires before replacing components. • Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board. • Refer to Service Manual for additional information. SH -- Shorted FZ thermistor SY CF UI to Main Control Board communication failure; on start up SY CE UI Main Control Board communication error; after a period in operation SY EF Evaporator fan failure INCANDESCENT LIGHTING MODELS ONLY FF DOOR SW. SENSE REFRIGERATOR LIGHTS FZR DOOR SW. SENSE FREEZER LIGHTS NEUTRAL IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

Upload: others

Post on 23-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SERVICE DATA SHEET Diagnostic Mode 0° F …manuals.frigidaire.com/prodinfo_pdf/Anderson/242288302.pdf0 F FREEZER & 37 F FRESH FOOD (2500 ++ V5) Type A with Run/ Start Capacitor 65

SERVICE DATA SHEET242288302

ICE & WATER - AUTOMATIC DEFROST

SIDE BY SIDE - R134a

CAUTIONAll electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.

Diagnostic Mode

Activate: Press ^ and V temperature pads for up to 10 sec. simultaneously. Press + to advance through tests.

Deactivate: Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm.

• Tests marked with “*” may not be applicable to this unit and will not be displayed in Diagnostic Mode.• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.

Test To activate test: Passing result

-- First Screen -- All LED lights on UI illuminated

-- Second Screen -- All segments on UI temperature displays illuminated

-- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+” blinking on FF display side to show location.

28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released

1* Standard Compressor and Condenser Fan

Press set Compressor and Condenser Fan running when “on”; stopped when “off”

2 Defrost Heater Press set Defrost limit switch must be closed; verify “CL” in test 26.Feel for heat from defrost heater when “on”.If “OP” in test 26, heater will not activate.

3 FF Light Press set With FF door open, FF lights on when “on”; off when “off”

8 Water Valve (Dispenser)

Press set Be prepared to collect water at dispenser.Water dispenses when “on”; stops when “off”

9 FZ Light Press set With FZ door open, FZ lights on when “on”, off when “off”

10 Auger Motor Press set FZ door must be closed.Motor running when “on”; motor stopped when “off”

11 Cube/Crush Solenoid

Press set Do not leave solenoid in activated state.Solenoid activated when “on”; deactivated when “off”

41* Perfect Temp Drawer (PTD)

Press set PTD UI illuminated when “on”, off when “off”

12* VCC Condenser Fan Press set Fan running when “on”; stopped when “off”

38* VCC Compressor Press set Compressor running when “on”; stopped when “off”

15 Evaporator Fan Press set Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when “off”. Feedback failure if fan starts but runs less than 10 sec. Listen for speed change from “LO” to “HI”.

22 Damper Press set With inspection mirror, observe damper open when “OP”; closed when “CL”

23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open

24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open

26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open

36 Ice Chute Door Depress ice chute door or press set

“OP” on UI when manually opened; “CL” when closed. Or, using “set”, “OP” on UI when fully opened or "CL" when fully closed by the motor.

29 FF Thermistor Mid-level

Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at mid-level FF thermistor location. “OP-” if open; “SH-” if short

30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gage at FZ thermistor location.“OP” if open; “SH” if short

33 Ambient Thermistor @ Main Board

Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short

35 FF Thermistor Upper-Level

Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within 10°F of temperature measured with gauge at upper-level FF thermistor location. “OP¯” if open; “SH¯” if short

34 Ambient Thermistor @ UI

Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-perature measured with gauge at UI location. “OP” if open; “SH” if short

46 Humidity Sensor Activates automatically “OP” if open, “SH” if shortAC Heater System: Displays %RHDC Heater System: “HI” – heater should be on “Lo” – heater should be off%RH is displayed when humidity is between “Lo” and “HI” values; heater could be on or off.

47* Dispenser Pocket Heater

Press set AC Heater System: “--” ; test not availableDC Heater System: heater on when “on”, off when “off”

0- Firmware Parameters Press set Displays digit sequence; record

2- Main Board Firmware Press set Displays digit sequence; record

4- UI Firmware Press set Displays digit sequence; record

Var

iabl

e C

apac

ity C

ompr

esso

r (V

CC

) D

iagn

ostic

s (s

elec

t mod

els)

If te

st 3

8 fa

ils, d

iagn

ose

as fo

llow

s:

Rep

lace

Inv

erte

r

→Ch

eck

at t

he c

onne

ctor

fr

om m

ain

cont

rol i

nto

the

inve

rter

(ty

pica

lly

BLK

and

RED

wire

s)

Is I

nve

rter

rec

eivi

ng

10

-15

VA

C

and

1-5

VD

C f

rom

M

ain

Con

trol

?

→Ch

eck

at M

ain

Cont

rol

Boar

d (B

LK/W

HT a

nd R

ED/B

LK w

ires)

Is M

ain

Con

trol

se

ndi

ng

10

-15

VA

C

and

1-5

VD

C t

o In

vert

er?

no

→Ch

eck

at t

he c

onne

ctor

fro

m

the

serv

ice

cord

into

the

in

vert

er (

typi

cally

PU

R a

nd

WH

T w

ires.

)

Is I

nve

rter

rec

eivi

ng

11

5

VA

C f

rom

pow

er s

upp

ly?

yes

•Ch

eck

volta

ge s

uppl

y.•

Chec

k an

d re

pair

serv

ice

cord

w

iring

an

d co

nnec

tions

.

no

Iden

tify

and

repa

ir da

mag

ed w

ires

or

poor

co

nnec

tions

bet

wee

n M

ain

Cont

rol a

nd

Inve

rter

yes

→Rem

ove

inve

rter

box

fr

om t

he c

ompr

esso

r an

d ch

eck

resi

stan

ce

acro

ss c

ompr

esso

r w

indi

ng p

airs

as

show

n.

Is r

esis

tan

ce a

cros

s al

l win

din

g pa

irs

equ

al?

yes

Rep

lace

Com

pres

sor

no

→Ch

eck

conn

ectio

ns

from

Inv

erte

r t

o Co

mpr

esso

r

Are

con

nec

tion

s fr

om I

nve

rter

to

Com

pres

sor

inta

ct?

yes

yes

Iden

tify

and

repa

ir da

mag

ed w

ires

or p

oor

conn

ectio

ns b

etw

een

Inve

rter

and

Com

pres

sor.

no

VC

C R

esis

tan

ce C

hec

kCh

eck

resi

stan

ce b

etw

een

term

inal

s 1

and

2, 2

and

3, 3

and

1.

If a

ll re

sist

ance

s ar

e eq

ual,

com

pres

sor

is o

pera

tive.

Rep

lace

Mai

n Co

ntro

ln

o

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 0° F FREEZER & 37° F FRESH FOOD (2500 ++ V5)

Type A with Run/Start Capacitor

65°F (18°C) Ambient 90°F (32°C) Ambient

Variable Speed Standard Variable Speed Standard

Operating Time 74 to 84% 32 to 40% 100% 55 to 65%

Freezer Temperature

-2° to 2° F -19° to -17° C

0° to 4° F -18° to -16° C

-1° to 3° F -18° to -16° C

-1° to 3° F -18° to -16° C

Refrigerator Temperature

34° to 39° F 1° to 4° C

34° to 39° F 1° to 4° C

34° to 39° F 1° to 4° C

34° to 39° F 1° to 4° C

Low Side Pressure (cut-in)

5 to 12 psig 43 to 83 kPa

5 to 12 psig 43 to 83 kPa

N/A5 to 12 psig 43 to 83 kPa

Low Side Pressure (cut-out)

-2 to 2 psig -14 to 14 kPa

-2 to 2 psig -14 to 14 kPa

-2 to 2 psig -14 to 14 kPa

-2 to 2 psig -14 to 14 kPa

High Side Pressure (last 1/3 cycle)

90 to 105 psig 621 to 724 kPa

90 to 115 psig 621 to 793 kPa

120 to 135 psig 827 to 931 kPa

130 to 155 psig 896 to 1069 kPa

Wattage (last 1/3 cycle) 50 to 60 90 to 130 60 to 70 100 to 140

Amps (running) 0.5 to 0.9 0.7 to 1.1 0.6 to 1.0 0.8 to 1.2

Base Voltage 115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet SizeThermostat Heater

Cut-in Cut-out Watts Ohms

23’ CD, 26’ 25° F (-4° C) 47° F (8° C) 450 30

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

Watts RPM Amps

3.1 1100 CW Opposite Shaft 0.03 Running

OU

T 1A

OU

T 2A

OU

T 1B

OU

T 1B

ERF-

2500

++ V

5RE

FRIG

ERA

TOR

CON

TRO

L

NTC

1 -

FF

NTC

2 -

FF

NTC

- F

Z

DEF

ROST

HEA

TER

DEF

ROST

TH

ERM

.N

EUTR

AL

CON

TRO

L

GRO

UN

DIC

E FL

APP

ERSO

LEN

OID

+5V

+5V

+5V

DC

EVA

PORA

TOR

FAN

M

DA

MPE

RM

OTO

RM

FG

VCC(

+12)

COM

VS

VCC

COM

PRES

SOR

CON

DEN

SER

FAN

STA

ND

ARD

COM

PRES

SOR

M

COM

MO

N

HIG

H

LIN

E

AM

BIEN

TN

TC

DEF

ROST

SEN

SE

LIN

E

G5L

E RE

LAY

LIN

EN

EUTR

AL

AU

GER

MO

TOR

LIN

E

CUBE

/CRU

SHED

ICE

GA

TE C

ON

TRO

L

M

DO

ORSW

ITCH

NEU

TRA

LLI

NE

LIN

E

J3-1

6

J3-3

J3-3

J3-

7

DIS

PEN

SER

VALV

E

PRIM

ARY

VA

LVE

ICE

MA

KER

FILL

VA

LVE

ICE

MA

KER

FILL

SW

ITCH

G8P

REL

AY

J4-B

1-6

J4-B

1-1

J4-B

1-2

J4-B

1-3

J4-A

1-9

J4-A

1-3

J4-A

1-10

J4-A

1-4

J4-A

1-11

J4-A

1-5

J2-

1

J3-

2

J3-1

J2-2

J1-4

J4-B

1-4

J4-A

1-6

J4-A

1-7

J4-B

1-5

J4-A

1-13

J4-A

1-14

J8-

5J8

-6

J8-

7J8

-8

JF-

1JF

-2

JF-

3JF

-4

ASS

Y_O

UT

ASS

Y_IN

+5V

GRO

UN

D

+5V

RESE

T_FL

ASH

BKG

D/M

SJG

ROU

ND

J9A

-1J9

A-2

J9A

-3

VEE

(+12

V)CO

MM

GRO

UN

D

ISOLATED

USERINTERFACE

J1-1

J2-9

J2-1

0J3

-13

J3-1

4J3

-15

J3-1

6J1

-3J2

-7

NEU

TRA

L (S

ERVI

CE C

ORD

)

NEU

TRA

L (C

ON

DEN

SER

FAN

)N

EUTR

AL

(WA

TER

VALV

E 1)

NEU

TRA

L (N

OT

USE

D)

NEU

TRA

L (C

OM

PRES

SOR)

NEU

TRA

L (L

ED P

OW

ER S

UPP

LY)

NEU

TRA

L (D

ISPE

NSE

R &

ICE

MA

KER

VALV

E)LI

NE

(SER

VICE

CO

RD)

LIN

E (V

cc C

OM

PRES

SOR)

J6-1

J6-2

J6-3

J6-4

J6-5

J6-6

J6-7

J6-8

ICE

MA

KER

FAN

PO

WER

TWIS

T TR

AY

MO

TOR

DIR

ECTI

ON

1TW

IST

TRA

Y SW

ITCH

NTC

PO

WER

ICE

MA

KER

FAN

GRO

UN

DTW

IST

TRA

Y M

OTO

R D

IREC

TIO

N 2

TWIS

T TR

AY

SWIT

CHN

TC F

EEBA

CK

TWIS

TIC

E M

AKE

R

ICE

& W

ATE

RD

ISPE

NSE

RCO

NTR

OL

OPT

ION

AL

LED

PO

WER

BOA

RD

J3-

1

J3-

4

J3-

3

NEU

TRA

L

FREE

ZER

LIG

HT

S

REFR

IGER

ATO

RLI

GH

TS

FZR

DO

OR

SW. S

ENSE

J3-9 J3-1

0

J2-1

2

J3-8

J3-1

1

J2-6

LIN

E

FF D

OO

R SW

. SEN

SE

Error Codes Special Modes

DisplayInterpretation Mode

Display Activate/Deactivate(press for up to 10 sec.

simultaneously)FZ FF FZ FF

-- OP- Open FF mid-level thermistor

Manual Defrost

d F + and -/same to deactivate

-- OP¯ Open FF upper-level thermistor

Display/Showroom

77 77 ^ and -/set

OP -- Open FZ thermistor Sabbath Sb Sb V and +/same to deactivate

-- SH-Shorted FF mid-level thermistor

Diagnostic No FF or FZ display, all UI LEDs on.

^ and V/+ to deactivate

-- SH¯ Shorted FF upper-level thermistor

Notes:• Always check for pin back-outs, pinched or damaged wires

before replacing components.• Determine whether failure is caused by the component, main

control board or wiring. Contact TID before replacing main control board.

• Refer to Service Manual for additional information.

SH -- Shorted FZ thermistor

SY CFUI to Main Control Board communication failure; on start up

SY CE UI Main Control Board communication error; after a period in operation

SY EF Evaporator fan failure

INCA

NDES

CENT

LIG

HTIN

G MO

DELS

ONL

Y

FF D

OOR

SW.

SENS

E REFR

IGER

ATOR

LIG

HTS

FZR

DOOR

SW.

SEN

SE

FREE

ZER

LIGH

TSNE

UTRA

L

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION

IMPORTANT SAFETY NOTEThe information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

Page 2: SERVICE DATA SHEET Diagnostic Mode 0° F …manuals.frigidaire.com/prodinfo_pdf/Anderson/242288302.pdf0 F FREEZER & 37 F FRESH FOOD (2500 ++ V5) Type A with Run/ Start Capacitor 65

242288401

ICE MAKER INFORMATIONTest Cycling

Press the momentary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle.

Water Fill Volume

The water fill can be adjusted without removing the ice maker cover. To adjust the fill size, remove the small round plug next to the On/Off Switch. Insert a #2 Phillips screwdriver into the hole about an inch or until it engages the Water Fill Adjustment Screw. Turn the screw clockwise to reduce the fill size; turn the screw counterclockwise to increase the fill size. One turn equals approx 20cc (0.68 oz). The correct fill is 85 to 95cc (2.75 to 3.25 oz). When a water valve is replaced, check the fill volume.

TUR

N MountingPlateScrews

MountingPlate

Screw

MotorGear

TimingGear

Water FillAdjustment

Ice MakerON/OFFSwitch

ICE MAKER SPECIFICATIONS

Electrical 115 vac (127 vac max)

Thermostat Opens at 48° F ( 9° C), Closes at 9° F ( -13° C)

Heater Wattage 112 watts

ICE MAKER CONNECTOR PLUG CONNECTIONS

Wire Number Wire Color Connects to:

1 Green/Yellow Ground

2 Yellow Water Valve

3 Black Line

4 Light Blue Neutral