079 ETA POWER CATALOG BOOK 2009 OB series ET series Product Lineup Ordering Information Features New TESLA Converter technology system Ultra small and light : open-frame type : amazing compactness as chassis mount type : W56 × L86 × H30 [mm], approx. 200 [g] : 20% or less in volume compared to equivalent ETA product (ETD05SC48/300) Super high efficiency : 94.5% (typical) at 5V output (ETD-SC48/300) : 95% (typical) at 5V output (ETF and ETG series) : 96.5% (typical) at 12V and 15V output (ETF12SC300/ETF15SC300) Safety standard : UL60950-1, CSA60950-1, EN60950-1 certified, CE (LV directive) compliant Environmental compliance : complied with RoHS directive Series name Output power (D : 100W class, F : 300W class, P : 450W class, G : 600W class) DC output voltage No. of output (S (single) : single output) DC input DC rated input voltage 300[V] DC200(220) to 400[V] 48[V] DC36 to 72[V] Safety standard certified 60950-1 safety standard certified General Description * "TESLA Converter"is a US patented and internationally patented (PCT) product. ETA Electric Industry Co., Ltd. is licensed to use the product. ( DC/DC ) Switching power supplies SERIES Super high efficiency 94.5 to 96.5% (typical) Notes for use of AC/DC-type synchronous rectification system Forward Type · No parallel connection is allowed. However, connecting two units using diode OR connection for the purpose of redundant operation is possible. · No series connection is allowed. However, series operation will be available if entry of current into the power supply is prevented by way of inserting diodes in series-parallel to output terminal of the power supply. · Capacity of external connection is not limited unless otherwise specified in overcurrent protection function (OCP) specifications. Please contact us for details in individual case. "TESLA Converter" (next-generation power supply) adopted : ultra small size and super high efficiency.Chassis module/open-frame type 1. Input Voltage Range DC36 to 72V(ET*-**SC48) DC200/220 to 380/400 (ET*-**SC300) 2. Output Voltage Range ±10% MAX 3. Operating Temperature -10 to +71 without thermal shock, derating required at 50˚C or above 4. Humidity 20 to 90 [ % R H](non-condensing) 5. Withstanding Voltage Input-Output : AC2000V Input-Case : AC2000V Output-Case : AC1000 for 1 minute each (DC48V input) Input-Output : AC3000V Input-Case : AC2000V Output-Case : AC1000 for 1 minute each (DC300V input) 6. Function Overcurrent protection, overvoltage protection, remote control, remote sense 7. Efficiency 95/96/96.5 [%] (typical (at rated input/output)

Upload: lyanh

Post on 21-Aug-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

079ETA POWER CATALOG BOOK 2009

OBseries

ETseries

Pro

du

ct Lineu

p

■ Ordering Information

■ Features●New TESLA Converter technology system●Ultra small and light : open-frame type : amazing compactness as chassis mount type : W56 × L86 × H30 [mm], approx. 200 [g] : 20% or less in volume compared to equivalent ETA product (ETD05SC48/300)●Super high efficiency : 94.5% (typical) at 5V output (ETD-SC48/300) : 95% (typical) at 5V output (ETF and ETG series) : 96.5% (typical) at 12V and 15V output (ETF12SC300/ETF15SC300)●Safety standard : UL60950-1, CSA60950-1, EN60950-1

certified, CE (LV directive) compliant●Environmental compliance : complied with RoHS directive

Seriesname

Output power (D : 100W class, F : 300W class, P : 450W class, G : 600W class)

DC output voltage

No. of output (S (single) : single output)

DC input

DC rated input voltage 300[V] DC200(220) to 400[V] 48[V] DC36 to 72[V]

Safety standard certified60950-1 safety standard certified

■ General Description

* "TESLA Converter"is a US patented and internationally patented (PCT) product. ETA Electric Industry Co., Ltd. is licensed to use the product.

(DC/DC)

Switching power supplies

SERIES

Super high efficiency

94.5 to 96.5% (typical)

Notes for use of AC/DC-type synchronous rectification system Forward Type· No parallel connection is allowed. However, connecting two units using diode OR connection for the purpose of redundant operation is possible.· No series connection is allowed. However, series operation will be available if entry of current into the power supply is prevented by way of inserting diodes in

series-parallel to output terminal of the power supply.· Capacity of external connection is not limited unless otherwise specified in overcurrent protection function (OCP) specifications. Please contact us for details in

individual case.

"TESLA Converter" (next-generation power supply) adopted : ultra small size and super high efficiency.Chassis module/open-frame type

1. Input Voltage Range DC36 to 72V(ET*-**SC48) DC200/220 to 380/400 (ET*-**SC300)2. Output Voltage Range ±10% MAX3. Operating Temperature -10 to +71 without thermal shock, derating required at 50˚C or above4. Humidity 20 to 90 [% R H](non-condensing)5. Withstanding Voltage Input-Output : AC2000V

Input-Case : AC2000VOutput-Case : AC1000 for 1 minute each (DC48V input)Input-Output : AC3000VInput-Case : AC2000VOutput-Case : AC1000 for 1 minute each (DC300V input)

6. Function Overcurrent protection, overvoltage protection, remote control, remote sense7. Efficiency 95/96/96.5 [%] (typical (at rated input/output)

Page 2: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

080 ETA POWER CATALOG BOOK 2009

ET SERIES (DC/DC)

ET Series (DC/DC)

[Input voltage : DC48V (36 to 72V) / DC300V (200/220 to 380V)]

100W/300W/600W Class, Single output

■ Product Lineup [Single output]

<Energy-saving and Space-saving>

New power supply system configuration achieved by chassis mount type productRecent DC/DC converters with large output capacity are more commonly provided as power-module type

units with higher component density, having compactness of brick size, half-brick size, and other smaller

sizes. However, such units are accompanied by a demerit that they require external components such as large

aluminum heatsink, cooling fan, and electrolytic capacitor.

On the other hand, 100W ET Series products do not need an additional heatsink despite their amazing

compactness, due to their high efficiency resulting in small self-loss (5.8W for 5V output product).

Furthermore, no external capacitor is needed due to a built-in output electrolytic capacitor they have.

Considering the above, as a way of configuring multi-output power supply system with large output, ETA

Electric is proposing a new method of mounting the ET Series product to a chassis, which has higher flexibility

over the method of mounting a power module on a printed circuit board for the above reasons.

Wattage Type Models Input voltage Output voltage Output current Efficiency

100W

ETD-SC48

ETD2.5SC48-U1

36 to 72V

2.5V 25V 92.5%ETD3.3SC48-U1 3.3V 25V 92.2%ETD05SC48-U1 5V 20V 94.5%ETD12SC48-U1 12V 8.4V 94.5%ETD15SC48-U1 15V 6.7V 94.5%ETD24SC48-U1 24V 4.2V 94.5%ETD48SC48-U1 48V 2.0V 94.5%

ETD-SC300

ETD1.8SC300-U1

200 to 380V

1.8V 25V 90.5%ETD2.5SC300-U1 2.5V 25V 92.5%ETD3.3SC300-U1 3.3V 25V 92.2%ETD05SC300-U1 5V 20V 94.5%ETD12SC300-U1 12V 8.4V 94.5%ETD15SC300-U1 15V 6.7V 94.5%ETD24SC300-U1 24V 4.2V 94.5%ETD48SC300-U1 220 to 380V 48V 2.0V 94.5%

300W ETF-SC300

ETF3.3SC300-U1

200 to 380V

3.3V 60V 94.0%ETF05SC300-U1 5V 60V 95.0%ETF12SC300-U1 12V 25V 96.0%ETF15SC300-U1 15V 20V 96.5%ETF24SC300-U1 24V 12.5V 96.0%ETF48SC300-U1 48V 6.3V 96.0%

450WETP-SC300

ETP24SC300 200 to 380V 24V 19V 95.5%

600WETG-SC300

ETG3.3SC300

200 to 380V

3.3V 120V 94.0%ETG05SC300-U1 5V 120V 95.0%

ETG12SC300 12V 50V 95.0%ETG24SC300 24V 25V 95.0%

NEW

NEW

NEW

Page 3: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

082 ETA POWER CATALOG BOOK 2009

ET SERIES (DC/DC)

Conditions: *1 : Inrush current varies depending on input/output conditions, such as output impedance of input power supply, input connection

line, power input circuit impedance. *2 : At rated input/output *3 : Measured by a bayonet probe with 100 [MHz] bandwidth oscilloscope at the end of a pair of 150 [mm] long output wires

terminated with a 100 [μF] electrolytic capacitor and a 0.1 [μF] film capacitor, giving no impact on exogenous noise *4 : Within operating temperature range *5 : For 8 hour period after 1 hour warm-up at rated input/output *6 : When output current changed between 25% and 75% of rated output current rapidly at rated input voltage *7 : The wire between the power supply and load should have an enough margin. Keep the line drop within 0.3 [V]. *8 : Inflowing current (IC) = 10 [mA] (maximum) when RC terminal voltage is applied

◎Caution *In order to protect you from possible electrification, do not attempt to touch any components inside the case while the power

supply product is operated. Since the case will also be heated, please be careful when you handle it *The power supply product should be started up after ensuring that the product has 0 [V] output voltage. It should not be restarted

while some output voltage still remains (only for 1.8, 2.5, 3.3, and 05). *In the event that reverse current may flow from the input of the product to input power supply, a blocking diode should be added to

the input line * The safety standard certification of this product is granted under the condition that DC voltage after rectifying/smoothing AC

(ripple voltage 30 [V] or less) is provided to the input side.

■ ETD ** SC300 Series (100W), Single output

ModelSpecifications

ETD1.8SC300-U1

ETD2.5SC300-U1

ETD3.3SC300-U1

ETD05SC300-U1

ETD12SC300-U1

ETD15SC300-U1

ETD24SC300-U1

ETD48SC300-U1

Input CharacteristicsRated Input Voltage [V] DC200 to 380Rated Input Current [A] DC0.28 to 0.15 DC0.37 to 0.20 DC0.48 to 0.25 DC0.48 to 0.25 DC0.50 to 0.28Inrush Current *1 Not specifiedEfficiency [%] (typical) *2 90.5 92.5 92.2 94.5 94.5 94.5 94.5 94.5

Output CharacteristicsOutput Voltage [V] 1.8 2.5 3.3 5 12 15 24 48Output Current [A] 25 25 25 20 8.4 6.7 4.2 2.0Voltage Adjust Range ±10% of rated output voltageRipple And Noise [mVp-p] (maximum) *3 150 150 150 150 220 250 340 580Regulation

a. Static Line Regulation [mV] (maximum) 15 20 26 40 100 120 120 120

b. Static Load Regulation [mV] (maximum) 16 23 30 45 110 135 135 135

c. Temperature Coefficient [mV/ ˚C] (maximum) *4 0.54 0.75 1.0 1.5 3.6 4.5 7.5 15d. Drift [mV] (maximum) *5 24 28 32 32 75 90 135 260e. Dynamic Load Regulation [mV] (maximum) *6 200 200 250 250 600 750 1200 1200

Rise Time 500 [mS] (maximum)Hold Up Time Not specified

Optional Functions

Overcurrent Protection 105% (minimum) of the rated current [A]

Output shutdown when voltage drops to 50% of rated output voltage (60% for 1.8 [V] product). Turn on at least 1 minute after the input voltage shutdown to restart.

Overcurrent protection function shuts down output when output voltage drops to 90% of rated output voltage or below. Turn on at least 1 minute after the input voltage shutdown to restart.

Overvoltage Protection 115% (minimum) of the rated voltage [V] Turn on 1 minute after the input voltage shutdown to restart

Remote Sense *7 Available (with load line form output terminal, connect + and - sensing terminals to + and - terminals of load line, respectively)Remote Control *8 Available (output OFF between RC terminals when 5 to 12 [V] is applied; output ON between RC terminals at open or 0 [V])

Environmental SpecificationOperating Temperature -10 to +71 [˚C] without thermal shock (see output derating table)Operating Humidity 20 to 90 [%RH] (non-condensing)Storage Temperature -20 to +85 [˚C] without thermal shockStorage Humidity 20 to 90 [%RH] (non-condensing)Withstanding Voltage Primary - Secondary AC3000V for 1 minute without defect, faradic current=20 [mA] Primary - Case AC2000V for 1 minute without defect, faradic current=20 [mA] Secondary - Case AC1000V for 1 minute without defect, faradic current=20 [mA]Isolation Resistance Primary - Secondary - Case 100 [MΩ] each

Vibration 5 to 10Hz : 10 [mm] double amplitude, 10 to 55Hz : acceleration 19.6 [m/s2]along X, Y, Z axes (non-operating)

Shock Impact force : 196 [m/s2]Cooling Convection cooling

Safety UL60950-1, CSA60950-1, EN60950-1 certified

CE (LV directive) compliant

Appearance/Weight Open-frame type / approx. 200 [g]Ref. MTBF [H] 270,000 270,000 270,000 270,000 264,000 264,000 289,000 288,000Ref. Frequency [kHz] (typical) 110Fix. 130Fix. 130Fix. 130Fix. 160Fix. 160Fix. 130Fix. 100Fix.

Page 4: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

086 ETA POWER CATALOG BOOK 2009

ET SERIES (DC/DC)Block Diagram

■ ETD ** SC48 Series (100W), Single output

SwitchingNoisefilter

Outputfilter

OCPsensing

Control

Sensing

OVPsensing

Switching

Control

Rectifying/Smoothing

Control

Synchro-nousrectifying

■ ETD ** SC300 Series (100W), Single output

SwitchingNoisefilter

Outputfilter

OCPsensing Control

Sensing

OVPsensing

Switching

Control

Rectifying/Smoothing

Control

Synchro-nousrectifying

■ ETF ** SC300 Series (300W), Single output

SwitchingNoisefilter

Output voltagesensing

OCPsensing Control

Sensing

OVPsensing

Switching

Control

Rectifying Rectifying

RectifyingRectifying

Control

Page 5: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

089ETA POWER CATALOG BOOK 2009

ETseries

ET SERIES (DC/DC)

Sensing

Output(-)

Output(+)

Remote control

Unit

Acceptable connectors

M3 countersink

Application Acceptable Housing Acceptable ContactConnector No.

Input

Remote sense

Remote control

Manufacturer: JST Mfg. Co., Ltd.

Connector joint

Pin No. Pin No. Pin No.

Output voltagesetting VR Label on the side

2-M3, maximum depth 6mm

2-M3 countersink

4-M3, maximum depth 3mm

Dimension Diagram■ ETD ** SC300 Series (100W), Single output

Dim

ensio

n Diag

ram

Page 6: SERIES (DC/DC) - your partner for Power Solutions · 086 ETA POWER CATALOG BOOK 2009 ET SERIES (DC/DC) Block Diagram ETD ** SC48 Series (100W), Single output Switching Noise filter

094 ETA POWER CATALOG BOOK 2009

ET SERIES (DC/DC)E

ffici

ency

[%]

Out

put

vol

tage

[V]

Output current [A]

DC300VDC5V25˚C

Input voltage Output voltage Ambient temperature

Output current [A]

DC300VDC5V25˚C

Input voltage Output voltage Ambient temperature

*Output will latch (=output shutdown) above here. For recovery, reducing the load to the rated current or below and reentering input are required.

· The power supply unit should be placed/mounted in the direction shown above.· If the power supply unit is used in the direction other than the above, forced air

cooling should be implemented (to discharge excess heat from inside of the unit).· When multiple power supply units are operated side by side, make sure that the

temperature around each unit is within the specified operating temperature range on the specifications before using the units.

Characteristics■ ETD ** SC300 Series (100W), Single output

■ Output current and efficiency curve ■ Overcurrent protection (OCP) curve

● Placing/mounting direction

■ Derating curve

Load

[%]

Ambient temperature [˚C]

When ambient temperature goes above 50 [˚C], an output should be lowered to the degree that the derating curb shown above is satisfied (by 5% per degree C when the ambient temperature is between 50 and 61 [˚C])

ETD48SC300-U1

Load

[%]

Ambient temperature [˚C]

This product is safety-standard certified subject to ambient temperature of 40 [˚C]. If you intend to have your finished product be safety-standard certified, please ensure to keep ambient temperature of the power supply unit at maximum of 40 [˚C]. If you are not applying for the certification, use the unit under the temperature condition as shown by the dotted line on the above derating curve.

ETD05SC300-U1