septic tank
DESCRIPTION
designTRANSCRIPT
ET 1 of 3
DESIGN OF SEPTIC TANK (200 USERS)1 SEPTIC TANK( R.C.C)
Size of sump : 6x 2.9 x 2.015M depth + 0.3M Free Board
Data: 2.2222
Length 6 m
Bredth 2.9 m 2.7
Depth 2.038 m avg depth 2.0375Free Board 0.3 m
Assumed thickness of Base Slab 0.3 m
Assumed thickness of cover Slab 0.125 m
Assumed Side Wall thickness 0.2 m
Concrete grade 30
Grade of Steel 500
Unit weight of water 10
Unit weight of soil 18
Unit weight of Concrete 25
Projection of base slab Y 0.25 m
Pipes & other fixtures Load 100 Kn
SBC 80
Edge coefficient 0.1
Clear cover for Wall 0.025 m
Area of Bottom Slab 22.1 Sqm
Dia of Bars for Base Slab 10 mm
Dia of Bars for Side walls 10 mma) Design of Bottom slab( Using uncracked theory)
Load transformed to Foundation
Load from water(L x B x H x Unit Weight of water) 354.525
249.645 206.1675
54.375
156.6Pipes & other fixtures 100
Total 915.145 KN 69.185
Pressure on soil 41.40928 SAFE
i) When tank is Empty
Up ward pressure on base slab W 25.367
As a two way slab 1.91 Two way
Bending Moment Coefficient from table 22 of IS 456 16.04186
Negative ( N)
***** Enter the value from table 26 of IS 456 0.087
0.087 16.04 3.1 = 13.41 KN-M
0 16.04 3.1 = 0.00 KN-M
K=Effective depth( d') /Total depth(d) 0.92
***** As per uncracked theory = 0.3*****
13.41 x 1000 x 1000
overall thickness 0.3 x 1000 = 211.44 mm
***** Provided thickness = 0.25 m or 250 mm
Effective depth Provided = 205 mm
= 501.34
Area of Steel Required = 501.34
Spacing required = 156.58
Provided Spacing = 100 c/c safe
provide # 10@100c/c in shorter span and # 10@ 100 c/c in long span
Check for minimum reinforcement for base slab
Percentage of steel coefficients 0.24
= 50.75
Required minimum area of steel = 507.46 mm2 safe
N/mm2
N/mm2
Kn/m3
Kn/m3
Kn/m3
KN/m2
Self weight of Side Wall ( L x H x Thick x Unit wt of Concrete)Weight of cover slab (L+Y)X(B+Y) X Depth x (Unit Weight of Concrete)Weight of base slab (L+Y)X(B+Y) X Depth x (Unit Weight of Concrete)
KN/m2
KN/M2
ly/lx
Positive (P)
Mx ( + Ve)= P x W x (Lx)2
Mx ( - Ve)= N x W x (Lx)2
M/bD2
cm2
mm2
cm2
ET 2 of 3
b) Design of side wall
Ratio Breadth(b)/Depth ( a) = 2.9=
1.42
2.0375
Asper Is 3370 part IV
0.01 10.00 8.458 = 0.85 KN-M
0.041 10.00 8.458 = 3.47 KN-M
0.016 10.00 8.458 = 1.35 KN-M
0.012 10.00 8.458 = 1.02 KN-M
K=Effective depth( d') /Total depth(d) = 0.99
As per uncracked theory = 0.3
3.47 x 1000 x 1000
overall thickness 0.3 x 1000 = 107.52 mm
200.00
effective depth provided < = 155.00 mm
Provide overal Thickness = 200.00 mm
Area of Steel Required (vertical) 66.91
= 66.91
Spacing required = 1173.27 mm
Provided vertical reinforcement Spacing = 150 c/c safe
Area of Steel Required (horizontal) 171.45
= 171.45
Spacing required = 457.86 mm
Provided horizontal reinforcement Spacing = 150 c/c safe
Check for minimum reinforcement for side wall
Percentage of steel coefficients 0.24
Required minimum steel = 372.00
Provide 10mm @150c/c
Check for tension on wall
From Table 8 of 3370-Part IV
Wall coefficient = 0.59
Tension on wall = 24.493 Kn
Permissable tensile stress = 150 N/mm2
Ast = 163.289 mm2
provide 8@ 150c/c in long span
Roof Slab
Slab thickness assumed is = 125 mm
clear cover taken as = 20 mm
assumed dia of bar = 8 mm
where effective depth = 101 mm
The panel size is = 6.13 x 3.03 c/c
l/b = 2.02
Concrete Mix = M30
Density of concrete = 25
Load On slab
self weight = 3.125
Floor finish = 1.5
Live Load = 2
Total Load on Slab = 6.625 6.70
Considering the slab as discontinuous in three sides
As per code IS 456
Short span +ve moment Mx = = 7.234 KN-m
Long span +ve moment My = = 1.778 KN-m
0.118
0.029
Percentage of steel is =
% of steel is along shorter span = 0.71
% of steel is along Longer span = 0.17
From sp16 Table 1
= 0.178
= 0.07
Area of steel Required (Ast) =100
Ast along short span = 179.78 ~ 206.75
Ast along Long span = 70.70 ~ 81.31
For dia of bar = 8
spacing required along short span = 243.00 ~ 200 c/c
spacing required along Long span = 617.920 ~ 200 c/c
Mx ( + Ve)= P x W x (Lx)2
Mx ( - Ve)= N x W x (Lx)2
My ( + Ve)= P x W x (Lx)2
My ( - Ve)= N x W x (Lx)2
M/bD2
mm2
mm2
mm2
w x a2
KN/m3
KN/m2 ~ KN/m2
αxwlx2
αywlx2
where αx =
where αy =
Mu
(bxd2)
Percentage of steel for Short span (Pt)
Percentage of steel for Long span (Pt)
(Pt x b x d)
mm2
mm2
ET 3 of 3
provide #8@ 200 c/c in shorter span and # 8@ 200 c/c in long span