Page 1: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

Leitz Metalworking Technology Group

Self cleaning HEPA Filter units High containment solutions

■ Highest Possible Efficiency■ Residual dust content : 0.1 – 0.0001mg/m■ Cleanest respectively contamination free

handling of the unit■ Airborne dust level during handling of the

system < 1µg/m3

Page 2: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

2

Containment at highest level, tailored for chemical andpharmaceutical production processes.A unique combination on the world market by providingnew standards in hygienic pharmaceutical manufacturingprocesses and meeting highest security requirements inproduction areas dealing with active compounds andtoxic products.These two aspects are the reason forthe takeover of ABSOLUT FiltertechnikGmbH by FETTE GmbH creating a newFETTE COMPACTING daughter com-pany the FETTE ABSOLUT GmbH.

In many branches of industry working indust free areas is an absolute must.Especially in the chemical and pharma-ceutical industry this has become neces-sary because of many aspects.On the one hand to avoid cross contami-nation with lowest possible OEL levelswith an airborne dust level during hand-ling of the system < 1 µg/m3 and highest possible filter efficiencies of 0.1 – 0.0001mg/m3

as a security for the purity of the product.On the other hand as a security for personnel working on production machines.A not less interesting aspect is recovering expensive products during production processes from the air.The necessary filter system which closes the gap betweenclean room technology and conventional dust filtration is provided by FETTE ABSOLUT.With systems linking together highest possible efficienciesand contamination free handling of the units.

Closing the gap between clean room

technology and filtration in industrial

processes.

Page 3: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

3

Customers from industrieswith highest requirements

Origin of the FETTE ABSOLUT filter system

■ The FETTE ABSOLUT filter system is based oninstalled units developed for the highest securitystandards required in the ventilation field of nuclearpower technology in order to prevent contamina-tion with radioactively charged dusts. Here greatest emphasis is laid on:– Highest possible efficiency by applying Hepa

filter cassettes– The consequent use of 2 Hepa filter stages to

guarantee security even in case a first stagefilter might leak

– Fully contamination free handling of the systemduring filter change and service intervals

– Guaranted 24 hours operation even in case ofthe failure of one module to be is isolated

■ These high safety standards in the ventilation fieldhave been transformed to the field of dust filtrationand dust recovery of even highest dust loads.

■ The FETTE ABSOLUT filter system is closing thegap between clean room technology and dustfiltration in industry and provides a state of the artsystem for even highest safety requirements.

Scientific research of the system

■ By the governmental research centre Karlsruhe,the self cleaning Hepa filter system is scientificallyresearched and evaluated1 as the state of the artsystem with a growing need in the market.

1M. Fronhöfer, H. Leibold: “Abreinigungstechnik für Schweb-stoffilter zur Entstaubung großer Volumenströme bei hohen Staub-konzentrationen”, FZKA-PEF-Berichte 135, September 1995H. Leibold, I. Döffert, J. G. Wilhelm: “Grundlagen und Technik derAbreinigung von Schwebstoffiltern durch Rückspülung”, KfK-PEF 109, August 1993

Industrial applications

■ Engineered products for high containmentsolutions in pharmaceutical production processes

■ FETTE ABSOLUT is manufacturing accordingGMP and FDA regulations and has developedtailored solutions for the special needs andrequirements of:– Pharmaceutical industry– Chemical industry– Cosmetic Industry– Food Industry.

■ Furthermore, the FETTE ABSOLUT system ishighly suitable for all branches of industries dealing with coarse to finest inhalable dustsespecially those which are hazardous to health,allergy causing, toxic or radioactively charged.

Page 4: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

4

Advantages of the FETTEABSOLUT filter system

Highest possible efficiency

■ Residual dust load of 0.1 – 0.0001mg/m3

■ Efficiency of 99,97% - 99,9997%■ Filter class H 10 to U 17 according EN 1822■ These values are reached because of:

– consequent application of self cleaning Hepafilters in stage 1

– the use of individual security Hepa filters instage 2

– highly developed machine construction– off line dedusting which makes the effective

recovery of finest dust possible.

Above:Type K 20/2.1,5 GMPMeasuring efficiency of stage 2 at DOP port.

Below:Laser particle counter to measure the efficiency of filter cassette stage 2. (Safety filter)

Page 5: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

Scanning : Particle counting in operation

■ Hepa Filters are normally only scanned afterthey have been manufactured.

■ The test protocol has practically no value, asduring packaging, transportation and installationinto the filter unit they can be damaged beforethey get in use.

■ Now it has become possible to test the securityfilter after being installed during operation.

■ Here the– Seal of the filter cassette and– The filter media are scanned.

■ A protocol documents the proper function of thecassette.

5

Automatic scanning tomeasure the efficiencyfilter cassette stage 2

Left:Type K 24/2.1,5 Scan

Below left:Measuring protocol. Unfiltered breathing air.

Below right:Measuring protocol. Quality of filtered air.

Page 6: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

6

Cleanest /contamination freehandling of the systemduring dust recovery

Standard series for machine rooms

Closing of butterfly valve at lowend of funnel.

Decoupling of can. Taking out of the closed plasticbag.

Inserting the new plastic bag. Inserting the new plastic bag. Sealing of the can to the filtersystem.

Opening of the butterfly valveat the low end of the funnel.

Closing the plastic bag with a lid.

Type MB 28/2.2 linked together with a glove box fordust recovery.

Page 7: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

7

GMP series in productionroom areas with integratedisolator.

Closing of the inner plastic bag

Decoupling the alpha port from the beta port.

Transporting the inner plastic bag into a LaCalhene valve system

Taking away the double sealed product within two bags.

GMP series for production rooms incl. integrated isolator.

Page 8: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

8

Opening of the servicing door. Pulling out of the used filtercassette.

Double sealing of the bag.

Cutting the plastic bag inbetween the two seals.

Inserting the new filter cassettewithin the new plastic bag.

Folding the new plastic bagand closing the door.

Packaging the sealed old filtercassette for disposal.

Taking out of the used filtercassette.

Cleanest/contamination freehandling of the system duringfilter change.

Filter change standard version■ According to cleanest or

contamination free dustrecovery it is possible tochange the hepa filter cas-settes accordingly in a cleanway or contamination free.

■ In multiple module machinesthis is also possible duringoperation by isolating onemodule out of the airflow.

■ This is done with the help of:– Safe change spigot and

plastic bag method.– Heat seal device

Left: Taking out used filter cassette.Above: Inserting new filter cassetteAccording DIN 25 414 (Nuclear technology)

Page 9: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

9

Filter change with additionalcomponents

Sealing of the used filter cassette. Taking away of sealed used hepa filter cassette.

Type MB 20/3.2 GMP with integrated glove box.

Trolley for filter change and heat sealing device

■ Height adjustable trolley for filter change and heat sealing of used filter cassette(s).

Wash/Wet in place

■ For additional security, cassettes can be sealedafter being washed internally (see page 10).

Page 10: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

10

Type K 20/1.1,5 WIP with integrated high pressure pump.

WIP Automatically washablefilter unit

Integrated washing system in filter module(s)

■ In order to provide a fully contained system ithas become necessary dealing with activecompounds or toxic products to integrate:

■ A low pressure wet in place system to wet:– the filter cassettes before being taken out,

and– the filter module(s) before being serviced,or

■ A high pressure wash in place system to wash:– The filter cassettes before being taken out.– the filter module(s) before being serviced:– Wash the complete system in case changing

the product to be filtered.

■ The water can be lead off automatically, orsucked away by an existing vacuum transfersystem for dust recovery.

■ Thus the centralised dust recovery system isintegrated into the washing process too.(See page 6)

Page 11: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

11

Proof of recovered product out of the air

■ In pharmaceutical production processes dealingwith hazardous to health, or dangerous products it has become a requirement to protocol and prove – How much product has been manufactured

and– How much product has been withhold not

being released ■ To state how little product has gone lost in a

process.– The weighing of the recovered product is

done automatically within the isolator.– The weighing protocol is printed within the

unit for documentation.

Weigh, automatic weighing ofthe recovered product

Type K 20/2.1,5 GMP Activating the measuring device.

Taking out the measuring protocol.

Page 12: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

12

Conventional safety devices

■ Conventional safety devices such as – Rupture discs – Automatic explosion suppression systems– Quick action flaps are installed according

customer´s requirements.

■ As a result of detailed explosion tests an additional safety feature can be provided also in case conventional suppression systems arefailing by– construction wise adapting the system to

minimize the positive pressure in case of anexplosion.

– re – enforcing the body to hold the minimizedpositive pressure.

Explosion safety in case ofdust explosions

Type K 24/1.1,5 EX

Page 13: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

13

Function of the self cleaningHepa filter system

■ Schematic function of the filter system:– the incoming dust laden air is lead decisively

into each individually operating module on itstop to create a gravimetric pre–filtration as acyclone effect.

– The down going air is lead upward again – By enlarging the inner room the speed of the

dust laden air is dropped from 20m/sec to 1-2cm/sec when reaching the filter media.

– The dust recovery system has to be adaptedto the calculated dust load reaching thesystem and according to the danger of theproduct.

– The dust laden and purified air channels areintegrated into the system.

■ Self cleaning Hepa filter cassettes stage 1 asactive filters– are designed to cope with highest dust loads

of up to 150g/m3/h– they provide a highest possibly efficiency of

finest dusts and aerosols of 0.3µm absoluteand have a residual dust load of 0.1mg/m3.

■ Safety Hepa filter cassettes stage 2 as passivefilters– each individually operating Hepa filter stage

one has its individual safety filter stage 2.– In case of a leakage in stage one only its

security filter is charged.– Guaranteed residual dust load 0.0001mg/m3.

■ Off line dedusting – the modular construction allows to isolate a

module by closing it during a dedusting cycle.Finest dusts and aerosols can only be recovered effectively off line.

– The airflow passing this module is taken overfrom the other module(s) remaining on line.

Self cleaning phaseFiltration phase

Filter system, filtration, dedusting

■ The self cleaning Hepa filter system is made insingle and two stage versions.

■ It is a multiple modular construction with a capacity ranging between 300 to 33,000 m3/h .

■ 25 standardised different module series are avail-able to provide tailored solutions when beingassembled according customer´s requirements.

Page 14: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

14

Triple Security

■ Triple seal of filter cassettes to the purified airarea.– Double seal for filter cassette stage 1– Single seal for filter cassette stage 2

■ Lowering of dust laden air area below filtercassette stage 1– Thus filter cassettes stage 1 and 2 are on the

clean air side.■ Spring pneumatic sealing device for cassettes.■ Leak control of seal and filter media

– visually or– by measuring at DOP ports, or– by scanning and particle counting

■ Sealing of the filter cassettes upward as providing the most benefits

Ways of sealing Hepa filter cassettes

Requirements a filter unit should meet*1 2

Visual control of seal and filter + -media possible

During filter change the clean area of the + -filter unit is not dirtied

During filter change the sealing frame for the + -filter cassette is not dirtied to prevent leakages

Increasing pressure differential of filter cassette + -should support the sealing mechanism*

The weight of the filter cassette should support - +the sealing mechanism*

DOP test of filter media and seal + +possible in operation

+ = Requirement is met - = Requirement is not met**Source: Kerntechnik 15. Jahrgang (1973) Nr. 9, S. 416-423

Sealing Hepa filter cassettesfrom the dust laden air - to the purified air side

Installation acc. drawing

Third seal from dust laden air topurified air side.

Filter cassette stage 2

Window

Rail for nozzle carriage

Nozzle carriage

Second seal from dust laden air topurified air side

Filter cassette stage 1

Spring pneumatic sealing deviceFirst seal from dust laden air topurified air sidePre filtration device

Funnel

Drawing 1 Drawing 2

Sealing upward

Sealing downward

Direction of airflow

Direction of airflow

Page 15: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

15

Best possible function control Examples:■ All mechanical components, drives attachment

and capacity of the system are controlled andmonitored according their function.

■ All filter modules and filter cassettes are individually controlled and monitored.

■ Filter cassette stage one:The reading of the pressure differential of onecassette shows:– The level of being dirtied of the cassette– The proper function of the dedusting mecha-

nism, shut off valves and blow valves.■ Filter cassette stage two:

The reading of the pressure differential of onecassette shows:– The level of being dirtied of the cassette– Possible leakage of media or seal of its stage 1

■ Automatic cleaning of the measuring points ofPressure differential guarantees exact measu-ring results.

■ Visual control above first and second filter stage– To control the proper function of the de-

dusting mechanism or the scanning device.– To control the seal and the filter media of the

cassette installed.

Conventional control panel for machine rooms with individualpressure differential control of each Hepa filter cassette

For machines installed in production room areas,touch screen panels providing most possible information,are available.

Visual control of the interior of the filter unit in operation.

Page 16: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

16

FETTE ABSOLUT high efficiencyHepa filter cassettes

Self cleaning Hepa filter cassettes stage 1

■ Residual dust load 0.1 mg/m3

Filter class H 13 according EN 1828■ Storage capacity for dust loads of up to 150g/m3

■ Strong construction to hold max pressure differential of 3,500 Pascals

■ Grounding of filter cassette with vibration proofplug contact– Resistance R < 106 Ohm acc VDE

■ Coated filter media for surface filtration■ Stainless steel frame according GMP guidelines.■ Capacities from 500 – 2,100m3/h per cassette

Purified air side Dust laden air side

Security Hepa filter cassette stage 2

■ Residual dust load 0.0001 mg/m3

Filter class H 14 – U 15 according EN 1828■ Storage capacity in case of leakages stage 1■ Strong construction to hold max pressure diffe-

rential of 1,500 Pascals and prevent a breakingof the filter media.

■ Grounding of filter cassette with vibration proofplug contact– Resistance R < 106 Ohm acc VDE

■ Stainless steel frame according GMP guidelines.■ Capacities from 500 – 3,500m3/h per cassette.

Self cleaning Hepa filter cassettes

Page 17: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

17

Survey of filter unit series

Series of unit types in 4 different construction levels

Machine room series

■ B FETTE ABSOLUT Basic version– Capacity from 300 to 33.000m3/h. Residual dust content 0.1 mg/m3.– Single stage self cleaning Hepa filter units with cleanest possible bag in bag out dust recovery

and filter change.– Hygienic, high efficiency filter system tailored to filter non hazardous products in chemical,

pharmaceutical, food and cosmetic industries.

■ S FETTE ABSOLUT Standard version– Capacity from 300 to 33.000m3/h. Residual dust content 0.1 - 0.0001 mg/m3.– Designed according standards in Germany in machine rooms in chemical and – pharmaceutical industries. – Single or two stage self cleaning hepa filter units with cleanest possible bag in bag out dust

recovery and filter change.– Highly sophisticated control technology with SPS controller.– Recirculation of filtered air possible

Production room series for chemical and pharmaceutical production areas

■ PH FETTE ABSOLUT Pharma version– Capacity 300 to 5.000 m3/h. Residual dust content 0.0001 mg/m3.– Designed to be installed in production room areas as close as possible to production machines.– Single sided two stage self cleaning Hepa filter units with smooth surface outside and cleanest

possible dust recovery and filter change by bag in bag out method. – Highly sophisticated control technology with SPS controller.– Recirculation of the filtered air recommended.

■ GMP FETTE ABSOLUT GMP version– Capacity 300 to 5.000m3/h. Residual dust content 0.0001 mg/m3.– Manufactured according GMP requirements.– Designed to be installed in production room areas as close as possible to production machines.– Double sided filter unit with smooth surfaces inside and outside.– Two stage self cleaning Hepa filter unit with contamination free handling of the system during

dust recovery, servicing and filter change.– Highly sophisticated control technology with touch screen panel.– Technology based on state of the art standard.– Recirculation of filtered air recommended.

Page 18: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

18

Abbreviations / unit versions

■ DOP Unit with DOP ports To measure efficiency of safety filter stage 2

■ EX Explosion protected unitsWith re-enforced body and explosion suppression devices

■ IMO Individual module operation (MB series)Individually operating modules assembled to one filter unit with one control and one fan.The modules of the filter unit are linked together with different machinesThe in going dust is recovered separately.

■ K Compact single module unitsIn one or two stage version.

■ MB Multiple module unitsIn one or two stage version.

■ Minipli Safety Hepa filter stage 2 With enlarged filter area for higher capacity

■ OSA One side access (MB series)Multiple double module units in one or two stage version assembled back to back.With one side access to filter cassettes to reduce space needed for the filter unit.

■ Scan Scanning of security filter stage 2 in operationAutomatic testing of the seal and the filter media of the security filter stage 2 with the helpof a scanning mechanism installed in the filter unit and a laser particle counter.

■ SF Single funnel (MB series)Multiple double module units with individual funnel for each double module Assembled back to back. Here height of the system is reduced remarkably.

■ TF Twin funnel (MB series)Multiple double module units with one funnel for each double module assembled back to back.

■ Twin Two stage compact unitWhereby first and second stage modules are assembled side by side to reduce height ofthe unit.

■ Weigh Fully automatic weighing systemincl. printer to protocol recovered product from the air.

■ WIP Wash in place / Wet in placeHigh pressure pump washing the system with spray heads automatically before servicing,filter change or product change.Or without high pressure pump to wet the system before opening it to avoid contamination.

Page 19: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

FETTE ABSOLUT self cleaning Hepa filter cassettes stage 1

Survey Hepa filter cassettes

Volume Type Dimensions Filter Specific Initial Final Tempe- Dustflow W x D x H surface Filter area Pressure Pressure rature ladenmax. load loss loss max. air max.

m3/h mm m2 m3/m2/h Pascal Pascal Celsius g/m3

750 HF1/10G 305x610x292 10 75 150 3.500 120 150

1.000 HF1/10GM 305x610x292 10 100 200 3.500 120 150

1.500 HF1/20G 610x610x292 20 75 150 3.500 120 150

2.000 HF1/20GM 610x610x292 20 100 200 3.500 120 150

1.800 HF1/24G 762x610x292 24 75 150 3.500 120 150

2.400 HF1/24GM 762x610x292 24 100 200 3.500 120 150

2.100 HF1/28G 915x610x292 28 75 150 3.500 120 150

2.800 HF1/28GM 915x610x292 28 100 200 3.500 120 150

19

■ Residual dust load: 0.1mg/m3

■ Efficiency: 99.97%

FETTE ABSOLUT security Hepa filter cassette stage 2

Volume Type Dimensions Filter Specific Initial Final Tempe-flow W x D x H surface FIlter area Pressure Pressure rature max. load loss loss max.

m3/h mm m2 m3/m2/h Pascal Pascal Celsius

750 HF2/10MP 305x610x150 10 75 150 1.500 120

750 HF2/10G 305x610x292 10 75 150 1.500 120

1.300 HF2/17MP 305x610x292 17 75 150 1.500 120

1.500 HF2/20MP 610x610x150 20 75 150 1.500 120

1.500 HF2/20G 610x610x292 20 75 150 1.500 120

1.800 HF2/24MP 762x610x150 24 75 150 1.500 120

1.800 HF2/24G 762x610x292 24 75 150 1.500 120

2.100 HF2/28MP 915x610x150 28 75 150 1.500 120

2.100 HF2/28G 915x610x292 28 75 150 1.500 120

2.550 HF2/34MP 610x610x292 34 75 150 1.500 120

2.850 HF2/38MP 762x610x292 38 75 150 1.500 120

3.150 HF2/42MP 915x610x292 42 75 150 1.500 120

■ Residual dust load: 0.0001mg/m3

■ Efficiency: 99.9997%

Attachments / Options

■ Grounding of filter cassettes stage 1 and 2– with vibration proof plug contact– Resistance < 106 Ohm according VDE

■ Filter frame made of stainless steel.■ Spacers made of stainless steel.

■ Plastic bag for contamination free filter change■ Rubber ring for attachment of plastic bag onto safe

change spigot■ Heat sealing device■ Height adjustable trolley for heat sealing and filter change

G =grounded stage 1 und 2filter cassette

M = membrane (Coatet filter media-stage 1 for higher air capacity)

MP = Minipli folding of filtermaterial stage 2 for higher air capacity

Page 20: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

20

Single module series K

■ Filter unit version

■ Capacity: 300 – 2.100 m3/h

■ Volume flow single module/K series

Multiple module series MB

■ Filter unit version

■ Capacity 2,000 to 33,600 m3/h and unit.(For higher airflows filter units have to beinstalled in parallel)

■ Volume flow multiple module/MB series

Survey self cleaning Hepa filter units

Volume flow Single stage Two stage[m3/h] unit type unit type

2.000 - 2.500 MB 20/2.1 MB 20/2.22.600 - 3.000 MB 24/2.1 MB 24/2.23.100 - 3.500 MB 28/2.1 MB 28/2.23.600 - 4.500 MB 20/3.1 MB 20/3.24.600 - 5.400 MB 24/3.1 MB 24/3.25.500 - 6.000 MB 20/4.1 MB 20/4.2

MB 40/2.1 MB 40/2.26.100 - 6.300 MB 28/3.1 MB 28/3.26.400 - 7.200 MB 24/4.1 MB 24/4.2

MB 48/2.1 MB 48/2.27.300 - 7.500 MB 20/5.1 MB 20/5.27.600 - 8.400 MB 28/4.1 MB 28/4.2

MB 56/2.1 MB 56/2.28.500 - 9.000 MB 20/6.1 MB 20/6.2

MB 24/5.1 MB 24/5.2MB 40/3.1 MB 40/3.2

9.100 - 10.500 MB 20/7.1 MB 20/7.2MB 28/5.1 MB 28/5.2

10.600 - 10.800 MB 24/6.1 MB 24/6.2MB 48/3.1 MB 48/3.2

10.900 - 12.000 MB 20/8.1 MB 20/8.2MB 40/4.1 MB 40/4.2

12.100 - 12.600 MB 24/7.1 MB 24/7.2MB 28/6.1 MB 28/6.2MB 56/3.1 MB 56/3.2

12.700 - 14.400 MB 24/8.1 MB 24/8.2MB 48/4.1 MB 48/4.2

14.500 - 14.700 MB 28/7.1 MB 28/7.214.800 - 15.000 MB 40/5.1 MB 40/5.215.100 - 16.800 MB 28/8.1 MB 28/8.2

MB 56/4.1 MB 56/4.216.900 - 18.000 MB 40/6.1 MB 40/6.2

MB 48/5.1 MB 48/5.218.100 - 21.000 MB 40/7.1 MB 40/7.2

MB 56/5.1 MB 56/5.221.100 - 21.600 MB 48/6.1 MB 48/6.221.700 - 24.000 MB 40/8.1 MB 40/8.224.100 - 25.200 MB 48/7.1 MB 48/7.2

MB 56/6.1 MB 56/6.225.300 - 29.000 MB 48/8.1 MB 48/8.229.100 - 29.400 MB 56/7.1 MB 56/7.229.500 - 33.600 MB 56/8.1 MB 56/8.2

Unittype

Filter surface stage1 [m2 ] per(double) module

/Amount of(double)modules

•Amount offilter stages

MB 40 5 2/ •

Unit-type

Filter sur-face stage1

[m2 ]/

Amount of dustladen air flapsand funnels

•Amount offilter stages

K 20 2 1/ •

Volume flow Single stage Two stage[m3/h] unit type unit type

300 - 750 K 10/1.1 K 10/1.1,5K 10/1.1.5 ScanK 10/1.2K 10/1. Twin

750 - 1.500 K 20/1.1 K 20/1.1,5K 20/1.1,5 ScanK 20/1.2K 20/1. Twin

1.500 - 1.800 K 24/1.1 K 24/1.1,5K 24/1.1,5 ScanK 24/1.2K 24/1. Twin

1.800 - 2.000 K 28/1.1 K 28/1.1,5K 28/1.1,5 ScanK 28/1.2K 28/1. Twin

Page 21: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

21

Self cleaning Hepa filter units

Filter cassette(s) Filter cassette(s)

Single module K series

Multiple module MB series Filter cassette size 610x610x292 mm

3.000 MB 24 / 2. 1 48 1984 970 2310 230 650

5.400 MB 24 / 3. 1 72 2896 970 2380 315 975

7.200 MB 24 / 4. 1 96 3808 970 2423 355 1300

9.000 MB 24 / 5. 1 120 4720 970 2460 400 1625

10.800 MB 24 / 6. 1 144 5632 970 2495 450 1950

12.600 MB 24 / 7. 1 168 6544 970 2525 450 2275

14.400 MB 24 / 8. 1 192 7456 970 2555 500 2600

2.500 MB 20 / 2. 1 40 1680 970 2295 200 590

4.500 MB 20 / 3. 1 60 2440 970 2355 280 885

6.000 MB 20 / 4. 1 80 3200 970 2395 315 1180

7.500 MB 20 / 5. 1 100 3960 970 2430 355 1475

9.000 MB 20 / 6. 1 120 4720 970 2460 400 1770

10.500 MB 20 / 7. 1 140 5480 970 2487 450 2065

12.000 MB 20 / 8. 1 160 6240 970 2515 460 2360

7.200 MB 48 / 2. 1 96 1984 1820 2423 355 1300

10.800 MB 48 / 3. 1 144 2896 1820 2495 450 1950

14.400 MB 48 / 4. 1 192 3808 1820 2555 500 2600

18.000 MB 48 / 5. 1 240 4720 1820 2605 560 3250

21.600 MB 48 / 6. 1 288 5632 1820 2655 630 3900

25.200 MB 48 / 7. 1 336 6544 1820 2695 710 4550

29.000 MB 48 / 8. 1 384 7456 1820 2740 800 5200

6.000 MB 40 / 2. 1 80 1680 1820 2395 315 1180

9.000 MB 40 / 3. 1 120 2440 1820 2460 400 1770

12.000 MB 40 / 4. 1 160 3200 1820 2515 450 2360

15.000 MB 40 / 5. 1 200 3960 1820 2565 500 2950

18.000 MB 40 / 6. 1 240 4720 1820 2605 560 3540

21.000 MB 40 / 7. 1 280 5480 1820 2645 630 4130

24.000 MB 40 / 8. 1 320 6240 1820 2670 650 4720

3.500 MB 28 / 2. 1 56 2290 970 2397 250 690

6.300 MB 28 / 3. 1 84 3355 970 2477 355 1035

8.400 MB 28 / 4. 1 112 4420 970 2522 400 1380

10.500 MB 28 / 5. 1 140 5485 970 2562 450 1725

12.600 MB 28 / 6. 1 168 6550 970 2597 450 2070

14.700 MB 28 / 7. 1 196 7615 970 2627 500 2415

16.800 MB 28 / 8. 1 224 8680 970 2667 560 2760

8.400 MB 56 / 2. 1 112 2290 1820 2522 400 1380

12.600 MB 56 / 3. 1 168 3355 1820 2597 450 2070

16.800 MB 56 / 4. 1 224 4420 1820 2662 560 2760

21.000 MB 56 / 5. 1 280 5485 1820 2717 630 3450

25.200 MB 56 / 6. 1 336 6550 1820 2812 710 4140

29.400 MB 56 / 7. 1 392 7615 1820 2862 800 4830

33.600 MB 56 / 8. 1 448 8680 1820 2912 830 5520

Filter cassette size 762x610x292 mm

Filter cassette size 915x610x292 mm

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of d

ust

lad

en a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Dust laden air flapFilter cassette(s)

B T

H

Symbolic drawing

300- K 10 / 1. 1 10 550 900 1580 80 150700 -125

1.200 K 20 / 1. 1 20 850 900 1780 150 200

1.800 K 24 / 1. 1 24 1002 900 1780 180 220

2.000 K 28 / 1. 1 28 1155 900 1780 200 250

Discontinuous operation With interruption of airflow during dedusting cycles for 30 seconds

Dust laden air flapFilter cassette(s)

B T

H

700- K 20 / 2. 1 20 850 900 1780 110 2001.200 -150

1.500 K 24 / 2. 1 24 1002 900 1780 160 220

1.800 K 28 / 2. 1 28 1155 900 1780 180 250

Continuous operation No interruption of airflow during dedusting cycles

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of d

ust

lad

en a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawing

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of p

urifi

ed a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawing

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of p

urifi

ed a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawing

■ Single stage FETTE ABSOLUT filter units■ Residual dust load 0.1 mg/m3

■ Self cleaning Hepa filter cassettes

Page 22: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

22

■ Two stage FETTE ABSOLUT filter units. Residual dust load 0.0001 mg/m3.

Self cleaning Hepa filter cassettes. Individual security Hepa filter in each module.

Single module K series

Filter cassette(s)

Multiple module MB series Filter cassette size 610x610x292 mm

Filter cassette(s)

3.000 MB 24 / 2. 2 48 48 1984 970 2835 230 860

5.400 MB 24 / 3. 2 72 72 2896 970 2905 315 1290

7.200 MB 24 / 4. 2 96 96 3808 970 2948 355 1720

9.000 MB 24 / 5. 2 120 120 4720 970 2985 400 2150

10.800 MB 24 / 6. 2 144 144 5632 970 3020 450 2580

12.600 MB 24 / 7. 2 168 168 6544 970 3050 450 3010

14.400 MB 24 / 8. 2 192 192 7456 970 3080 500 3440

2.500 MB 20 / 2. 2 40 40 1680 970 2820 200 800

4.500 MB 20 / 3. 2 60 60 2440 970 2880 280 1200

6.000 MB 20 / 4. 2 80 80 3200 970 2920 315 1600

7.500 MB 20 / 5. 2 100 100 3960 970 2955 355 2000

9.000 MB 20 / 6. 2 120 120 4720 970 2985 400 2400

10.500 MB 20 / 7. 2 140 140 5480 970 3012 450 2800

12.000 MB 20 / 8. 2 160 160 6240 970 3040 460 3200

7.200 MB 48 / 2. 2 96 95 1984 1820 2948 355 1720

10.800 MB 48 / 3. 2 144 144 2896 1820 3020 450 2580

14.400 MB 48 / 4. 2 192 192 3808 1820 3073 500 3440

18.000 MB 48 / 5. 2 240 240 4720 1820 3130 560 4300

21.600 MB 48 / 6. 2 288 288 5632 1820 3180 630 5160

25.200 MB 48 / 7. 2 336 336 6544 1820 3220 710 6020

29.000 MB 48 / 8. 2 384 384 7456 1820 3365 800 6880

6.000 MB 40 / 2. 2 80 80 1680 1820 2920 315 1600

9.000 MB 40 / 3. 2 120 120 2440 1820 2985 400 2400

12.000 MB 40 / 4. 2 160 160 3200 1820 3040 450 3200

15.000 MB 40 / 5. 2 200 200 3960 1820 3090 500 4000

18.000 MB 40 / 6. 2 240 240 4720 1820 3130 560 4800

21.000 MB 40 / 7. 2 280 280 5480 1820 3170 630 5600

24.000 MB 40 / 8. 2 320 320 6240 1820 3195 652 6400

3.500 MB 28 / 2. 2 56 56 2290 970 2928 250 920

6.300 MB 28 / 3. 2 84 84 3355 970 3003 355 1380

8.400 MB 28 / 4. 2 112 112 4420 970 3048 400 1840

10.500 MB 28 / 5. 2 140 140 5485 970 3088 450 2300

12.600 MB 28 / 6. 2 168 168 6550 970 3123 450 2760

14.700 MB 28 / 7. 2 196 296 7615 970 3158 500 3220

16.800 MB 28 / 8. 2 224 224 8680 970 3188 560 3680

8.400 MB 56 / 2. 2 112 112 2290 1820 3048 400 1840

12.600 MB 56 / 3. 2 168 168 3355 1820 3123 450 2760

16.800 MB 56 / 4. 2 224 224 4420 1820 3183 560 3680

21.000 MB 56 / 5. 2 280 280 5485 1820 3243 630 4600

25.200 MB 56 / 6. 2 336 336 6550 1820 3288 710 5520

29.400 MB 56 / 7. 2 392 392 7615 1820 3348 800 6440

33.600 MB 56 / 8. 2 448 448 8680 1820 3388 830 7360

Filter cassette size 762x610x292 mm

Filter cassette size 915x610x292 mm

Dust laden air flapFilter cassette(s)

B T

H

350 K 10 / 1. 1,5 10 10 550 900 2000 80 180

700 K 10 / 1. 2 10 10 550 900 2200 125 200

1.000 K 20 / 1. 1,5 20 20 850 900 2000 140 250

1.500 K 20 / 1. 2 20 20 850 900 2200 160 280

1.500 K 24 / 1. 1,5 24 24 1002 900 2000 160 260

1.800 K 24 / 1. 2 24 24 1002 900 2200 180 275

1.800 K 28 / 1. 1,5 28 28 1155 900 2000 180 280

2.000 K 28 / 1. 2 28 28 1155 900 2200 180 300

Discontinuous operation With interruption of airflow during dedusting cycles for 30 seconds

B T

H

Dust laden air flapFilter cassette(s)

700 K 20 / 2. 1,5 20 20 850 900 2000 125 210

1.200 K 20 / 2. 2 20 20 850 900 2200 150 250

1200 K 24 / 2. 1,5 24 24 1002 900 2000 150 260

1.500 K 24 / 2. 2 24 24 1002 900 2200 160 275

1.500 K 28 / 2. 1,5 28 28 1155 900 2000 160 285

1.800 K 28 / 2. 2 28 32 1155 900 2200 180 300

Continuous operation No interruption of airflow during dedusting cycles

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of d

ust

lad

en a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawingFilte

r su

rfac

e st

age2

[m2 ]

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of d

ust

lad

en a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawingFilte

r su

rfac

e st

age2

[m2 ]

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of p

urifi

ed a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawingFilte

r su

rfac

e st

age2

[m2 ]

Volu

me

flow

max

. [m

3 /h]

Typ

e /

Ser

ies

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of p

urifi

ed a

ir fla

ps

Wei

ght

kg

Filte

r su

rfac

e st

age1

[m2 ]

Am

ount

of f

ilter

sta

ges

Dia

met

er d

ust

lad

en

air

inle

t [m

m]

Wid

th

Dep

th

Hei

gt *

Measurementswithout fan

[mm]

Symbolic drawingFilte

r su

rfac

e st

age2

[m2 ]

Page 23: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

23

Dust filtration

■ Single stageself cleaningHepa filter units - Residual dust

load 0.1mg/m3

- Capacity300-33,000m3/h

■ Two stage selfcleaning Hepafilter units - Residual dust

load0.0001m/m3

- Capacity300-33,000m3/h

■ Unit series forMachine rooms: - Basic version- Standard

version

■ In Pharmaceuticalproduction rooms - Pharma version- GMP version

Product range filter units andattachments (Excerpt)

Ventilation

■ Single stageHepa filter units- Residual dust

load0.0001mg/m3

- Capacity300-64,000m3/h

■ Two stage Hepafilter unit - Residual dust

load0.0001mg/m3

- Capacity 300 –64,000m3/h

■ Unit series- Horizontal

version - Vertical version

Gas adsorption

■ Filter units as used in ventilation With activatedcarbon cassettesCapacity 300 – 16,000m3/h

■ Unit series- Horizontal

version- Vertical version

Laminar flowceilings / Personnelfloodgate

■ Laminar flowceilingsto re circulatefiltered air

■ Personal floodgate toisolate rooms toprevent crosscontamination

Glove boxes/Isolators

■ Basic gloveboxes to recoverproduct contaminationfree(Economy version)

■ Rated isolatorsleak testedAccording GMPrequirements Wip version incl. filtration

Page 24: Self cleaning HEPA Filter units High containment … cleaning HEPA Filter units High containment solutions ... GMP and FDA regulations and has developed ... – In case of a leakage

Scan Measuring ofefficiency of securityfilter in operation

■ DOP Ports and par-ticle counting stage 2

■ Scanning device fullyautomatic leak test ofseal and filter mediastage 2

Attachments/Options Filter unitsWash in Place WIP

■ Low pressure washingof system before servicing, or filter change.

■ High pressure washingof system before servicing, productchange or filter change.

Ex protected unit versions

■ New developed filtersystem and re- enfor-ced body to resistpositive explosionpressure.

■ Conventional relief /suppression systems.

Weigh Automatic weig-hing of dust recovered

■ Fully automatic weighing system toprotocol recoveredproduct.

Hepa filter cassettes

■ Self cleaning Hepa filter cassettes Stage 1 Class H 13 EN 1822

■ Security Hepa filter cassettes Stage 2 Class H14-U15 EN 1822

Spare parts / attachments (Excerpt)Activated carbon cassettes

■ Activated carbon cassettes

Contamination free filter change

■ Heat seal units■ Height adjustable trolleys for

filter replacement.

Planning and engineering

■ of turn key contain-ment solutions inpharmaceutical pro-duction processes.

ServiceService andmodernisation

■ of self cleaning Hepafilter units.

Recycling

■ of used filter cassettes

Particle counting

■ of room■ filter efficiency

Prin

ted

in G

erm

any

Nr.

(030

4e J

)

FETTE ABSOLUT GmbHHigh Containment SolutionsHauptstraße 139-141 · D-76461 MuggensturmTel.: +49 (0) 72 22 96 97-0 · Fax: +49 (0) 72 22 82 01 [email protected] · www.fette-absolut.de Leitz Metalworking Technology Group

All FETTE ABSOLUT filter units are construction wise delivered fully assembled after detailed quality and function tests

according standardised FAT protocols. There is no cost intensive assembly on customer´s site necessary.

Product range attachments /Options (Excerpt)