Solar Taurus 70 Gas Turbine Compressors - Onshore - 3-off Identical Units
Available - New and Unused
DETAIL AS FOLLOWS:
Purchased 2009 and delivered 2010. Stored as delivered from Manufacturer, Preserved and packed in secure Warehouse in Gabon West Africa. Manufacturer’s preservation undisturbed. Multi Shaft Solar Gas Turbine. Designed for Low Pressure Section of Compression Train. Continuous Rating. Gas Fuel. Digital Gauge Panel – VDU on Skid. Warranty to 2012.
JOB NO. ITEM NO. TAURUS 70
PURCHASE ORDER NO. TBD
SPECIFICATION NO.
REVISION NO. A DATE
PAGE 1 OF 10 BY COMBUSTION GAS TURBINE (API 616-4TH)
DATA SHEET, S.I. UNITS
TAURUS 70
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
APPLICABLE TO: PROPOSAL PURCHASE X AS BUILT
FOR UNIT TAURUS 70
SITE SERIAL NUMBER
SERVICE Gas Compressor NUMBER REQUIRED 3
X CONTINUOUS INTERMITTENT STANDBY DRIVEN EQUIPMENT Solar Compressors C166V, C335EL
MANUFACTURER Solar Turbines X MODEL TAURUS 70-10302 ISO RATING (3.17) 7690 kW, 10310 hp @ See line 11 RPM
NOTE: INFORMATION TO BE COMPLETED: BY PURCHASER BY MANUFACTURER BY MFR IF NOT BY PURCHASER GENERAL
CYCLE: REGEN X SIMPLE EXHAUST HEAT RECOVERY TYPE: SINGLE SHAFT X MULTI SHAFT DRIVEN EQUIPMENT: NORMAL SHAFT, kW @ RPM RATED SHAFT, kW @ RPM
OUTPUT SHAFT SPEED RANGE (4.1.5) X MIN 6000 RPM X MAX 12000 RPM
DESIRED MINIMUM SITE POWER kW @ RPM
OPERATION ATTENDED UNATTENDED X POTENTIAL MAXIMUM POWER (3.33) See line 22 kW PREDICTED PERFORMANCE LOCATION (4.1.19)
GAS TURBINE INCLUDING ALL LOSSES
SITE NORMAL SITE SITE
RATED DUTY MAX MIN
(3.45) (3.26) TEMP TEMP
DRY BULB TEMP., deg C 35 40 15
RELATIVE HUMIDITY, % 86 86 86
BAROMETER,
OUTPUT, kW 5918 5628 7115
HEAT RATE, LHV, kcal/kW-hr 2783 2845 2631
OUTPUT SHAFT SPEED, RPM 9540 9540 9540
AIR FLOW, kg/hr 81221 78502 92795
EXHAUST FLOW, kg/hr 82415 79664 94151
FIRING TEMP. (Note 3), deg C 760 760 760
GG EXHAUST TEMP.,
PT EXHAUST TEMP., deg C 527 534 502
CERTIFIED POINT (3.26)
INCLUDING STEAM WATER EFFECTS FOR
EMISSION CONTROL AUGMENTATION (4.1.9)
STEAM FLOW, kg/HR N/A N/A N/A N/A
WATER FLOW, m3/HR N/A N/A N/A N/A
INDOOR X OUTDOOR X GRADE
HEATED UNDER ROOF MEZZANINE
UNHEATED X PARTIAL SIDES
ELECRICAL AREA CLASSIFICATION (4.1.14)
NON-HAZARDOUS X HAZARDOUS
APPLICABLE CODE: NEC 500 NEC 505 IEC
CLASS: GROUP: IIA TEMP CODE:
AREA CLASSIFICATION: DIVISION X ZONE 2
THIRD PARTY CERTIFICATION REQUIRED (Note 2)
WINTERIZATION REQUIRED
TROPICALIZATION REQUIRED (5.4.6.6)
UNUSUAL CONDITIONS: DUST FUMES
CORROSIVE AGENTS (4.10.1.1)
OTHER (5.5.34)
NOISE SPECIFICATIONS: (4.1.10) (Note 1)
APPLICABLE TO MACHINE: (5.7.4.1)
SEE SPECIFICATION
APPLICABLE TO NEIGHBORHOOD: (5.7.4.2)
SEE SPECIFICATION
PAINTING:
X MANUFACTURER'S STANDARD
OTHER APPLICABLE SPECIFICATIONS:
API 616 GAS TURBINES FOR THE PETROLEUM, CHEMICAL
& GAS INDUSTRY SERVICES
GOVERNING SPECIFICATION (IF DIFFERENT)
X VENDOR HAVING UNIT RESPONSIBILITY (4.1.2) Solar
NOTE: All Data Sheets References to GG=Gas Generator
SS = Single Shaft and PT = Power Turbine
JOB NO. ITEM NO.
REVISION A DATE
PAGE 3b OF 10 BY COMBUSTION GAS TURBINE (API 616-4TH)
DATA SHEET, S.I. UNITS
TAURUS 70 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
*Power Turbine Rotor CONSTRUCTION FEATURES (NOTE 1) X SPEEDS:
MAX. CONT. RPM TRIP 12,600 RPM
X LATERAL CRITICAL SPEEDS (DAMPED)
FIRST CRITICAL 3030 (AF=3.19) RPM Turb Disk Bounce MODE
SECOND CRITICAL 6004 (AF=n/a) RPM Coupling Bend MODE
THIRD CRITICAL 19656 (AF=n/a) RPM Rotor Bend MODE
FOURTH CRITICAL RPM MODE
PROTOTYPE OR MODIFIED ROTOR SUPPORT (4.7.3.5)
TRAIN LATERAL ANALYSIS REQUIRED (D.1.3)
TRAIN TORSIONAL ANALYSIS REQUIRED (2.7.4.5)
TORSIONAL CRITICAL SPEEDS:
FIRST CRITICAL Note 1 RPM
SECOND CRITICAL Note 1 RPM
THIRD CRITICAL Note 1 RPM
FOURTH CRITICAL Note 1 RPM
VIBRATION: (4.7.4.5) (7.2.3 o) X ALLOWABLE TEST LEVEL SHAFT
50.8 micro meters P/P
CASE mm/SEC
MATERIALS OF CONSTRUCTION (4.10) COMPRESSOR ROTOR BLADES n/a
COMPRESSOR STATOR VANES n/a
SHAFT AISI 4340 BLADE/VANE COATING N/A
TURBINE WHEELS OR
STAGE NOZZLES BLADES DISCS
1
2
3
4
COMBUSTORS
COMPRESSOR CASING n/a
COMBUSTOR CASING n/a
TURBINE CASING 410SS X ROTATION, VIEWED FROM DRIVE END X CW CCW GAUGE BOARDS AND CONTROL PANELS
AIR COMPRESSOR:
STAGES MAX. TIP SPEED m/SEC
TYPE PRESSURE RATIO
CASING SPLIT (2.2.3) AXIAL RADIAL
ROTOR SOLID BUILT UP
GAUGE BOARDS
X LOCATION Digital Gauge Panel (VDU On Skid)
CONTROL PANELS (5.4.5.1.1) ON-SKID OFF SKID LOCAL
X OFF SKID REMOTE
WEATHER PROTECTION REQUIRED YES NO
SPECIFICATION
ANNUNCIATOR REQUIRED (5.4.4.8.5)
X VISUAL DISPLAY UNIT (VDU) X KEYBOARD
TURBINE:
STAGES 2 MAX. TIP SPEED 490.42 m/SEC
CASING SPLIT (4.2.3) AXIAL X RADIAL
ROTOR SOLID X BUILT UP COMBUSTORS: (4.3.2)
SINGLE MULTIPLE, NUMBER
X GAS LIQUID DUAL FUEL
MAXIMUM ALLOW TEMP. VARIATION °C
APPLICABLE PLANE
FUEL NOZZLES PER COMBUSTOR
WOBBE INDEX NO. REQD (4.3.7) MAX
MIN
CONTROL SYSTEMS TYPE (5.4.1.5)
MECH PNEU HYDRA ELECTRIC X ELECTRONIC
X MICROPROCESSOR BASED COMBINED
SIGNAL SOURCE N/A
SENSITIVITY N/A RANGE TO
TIME OF AC OUTAGE RIDEOUT N/A MIN (5.4.1.6)
SHUT OFF VALVES FOR SHUT DOWN SENSORS (5.4.4.9) N/A
STARTING SYSTEM (5.4.2.1)
MANUAL SEMI AUTOMATIC X AUTOMATIC
X PURGE (5.4.2.2) 4 minimum MINUTES (Note 2)
SEPARATE SHUTDOWN VALVE TEST DURING OPERATION N/A
MAINTENANCE INTERVALS, HOURS
X HOT GAS PATH INSPECTIONS 4000 hrs
X MAJOR OVERHAULS 30000 hrs
OTHER
GOVERNOR (5.4.3) X MFR'S STD. OTHER X MAKE A.B. X MODEL
CONSTANT SPEED X VARIABLE SPEED
ISOCHRONOUS DROOP
REMOTE SHUTDOWN SIGNAL X ELECTRIC
PNEUMATIC HYDRAULIC NONE
MANUAL SPEED CHANGER, RPM MAX.
MAINTAIN TURBINE SPEED UPON FAILURE OF CONTROL
SIGNAL OR ACTUATOR
Note 3
MIN.
NOTE (1) FOR MULTIPLE SHAFT TURBINES, COMPLETE ALL
APPLICABLE PROTIONS FOR EACH SHAFT.
JOB NO. ITEM NO.
PURCHASE ORDER NO. TBD
INQUIRY NO.
REVISION NO. C DATE
PAGE 1 OF 7 BY CENTRIFUGAL AND AXIAL COMPRESSOR
DATA SHEET (API 617-7TH Chapter 2)
S.I. UNITS 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
APPLICABLE TO: PROPOSAL PURCHASE AS BUILT
FOR UNIT Solar Compressor
SITE SERIAL NO.
SERVICE Gas Compression NO. REQUIRED 2
MANUFACTURER Solar Turbines DRIVER TYPE (1-3.1.1) Taurus 70-10302 Gas Turbine
MODEL C166V, Low Pressure (LP) Section of Compression Train DRIVER ITEM NO.
INFORMATION TO BE COMPLETED: BY PURCHASER BY MANUFACTURER MUTUAL AGREEMENT (PRIOR TO PURCHASE)
OPERATING CONDITIONS (ALL DATA ON PER UNIT BASIS)
GAS HANDLED (ALSO SEE PAGE )
GAS PROPERTIES (1-2.1.1.4)
(sm^3/h-e3)
WEIGHT FLOW, #/MIN (KG/HR) (WET) (DRY)
NORMAL OTHER CONDITIONS (1-2.1.1.1) LP Section HP Section A B C D
59.04 59.04
INLET CONDITIONS PRESSURE (kPaa)
TEMPERATURE
RELATIVE HUMIDITY (%)
MOLECULAR WEIGHT
Cp/Cv ( Kideal )
COMPRESSIBILITY (Z1 ) OR (ZAVG )
INLET VOLUME
4700 9526.6 46.5 50
1.24 1.238 0.8861 0.8005
DISCHARGE CONDITIONS PRESSURE (kPaa)
TEMPERATURE
Cp/Cv ( Kideal )
COMPRESSIBILITY (Z2 ) OR (ZAVG )
POWER REQUIRED (KW)
TRAIN POWER REQUIRED
POWER REQUIRED AT DRIVER INCL. EXT. LOSSES (GEAR, ETC.)
SPEED (RPM)
TURNDOWN (%)
POLYTROPIC HEAD (m-kgf/kgm)
POLYTROPIC EFFICIENCY (%)
CERTIFIED POINT
EXPECTED OPERATION AT EACH CONDITION (%)
PERFORMANCE CURVE NUMBER
9576.6 19483.8 110.5 116.7 1.209 1.207 0.902 0.8967 1765 1919
9540 18102
9145.7 8772.7 73.4 65.7
PROCESS CONTROL (1-3.4.2.1)
METHOD SUCTION THROTTLING VARIABLE INLET SPEED VARIATION DISCHARGE COOLED BYPASS
FROM BARA GUIDE VANES FROM 50 % BLOWOFF FROM
TO BARA (2-3.4.2.2) TO 105 % TO TO
SIGNAL SOURCE (2-3.4.2.1)
TYPE ELECTRONIC PNEUMATIC OTHER
RANGE 4 to 20 MA BARG
ANTI-SURGE SYSTEM (1-3.4.2.2) Solar's Antisurge Control System
REMARKS:
Notes:
Purchase for one or multiple units.
All items offered subject to prior sale.
Located ‘as is, where is’ Gabon West Africa.
Assistance can be offered by owners with any Export concerns.
Full Manufacturers Documentation Packages are available upon request.