Scanning Transmission Electron Microscope
![Page 2: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/2.jpg)
Outline
• History• Interactions of Electrons• Background• STEM• Components• Specimen Preparation• Mode • Image formation• Comparison
![Page 3: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/3.jpg)
![Page 4: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/4.jpg)
Cont…
• The first STEM was built in 1938 by Baron Manfred von Ardenne.(distroyed in air raid)
• Not developed further until the 1970.• Then Albert Crewe at the University
of Chicago developed the field emission gun.
• Then built a STEM able to visualize single heavy atoms on thin carbon substrates
![Page 5: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/5.jpg)
Interactions of electrons
![Page 6: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/6.jpg)
Ramiz Ahmad
![Page 7: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/7.jpg)
Back ground
• Maximum resolution, d
• STEM an electron’s velocity approaches the speed of light, c
![Page 8: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/8.jpg)
STEM
• The basic principle of image formation fundamentally different from static beam TEM
• small spot size is formed on the sample surface with the condenser lenses
• This probe is scanned on the sample surface
• the signal is detected by an electron detector, amplified and synchronously displayed on CRT with the scan coils
![Page 9: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/9.jpg)
Cont…
• DETECTOR1. Small disk on the column axis
which detects the transmitted beam (BF STEM image) or diffracted beam (DF STEM image)
2. Annular detector (a plate with a hole) which detects all the diffracted beams except the transmitted one (ADF STEM)
• Resolution limited by the spot sizehave poorer resolution but better
contrast
![Page 10: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/10.jpg)
Naveed Abbas
![Page 11: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/11.jpg)
Scattered beam electrons
• In STEM signal is detected by I. back scattered electrons(BSE)II. Transmitted beam electrons scattered at
some angles• In both cases, BSE and TBE, the signal
intensity is a function of the average atomic number of the sample volume and also phase contrast that interacted with the beam
• Thus providing atomic number and phase contrast
![Page 12: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/12.jpg)
Cont…
• In STEM, the electron beam is rastered (scan coil) across the surface of a sample in a similar manner to SEM, however, the sample is a thin TEM section and the diffraction contrast image is collected on a solid-state (ADF) detector.HAADF-high angle
annular dark-field
![Page 13: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/13.jpg)
TEM =
STEM
![Page 14: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/14.jpg)
Imran Doger
![Page 15: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/15.jpg)
Components
• Source formation- Field emission• Electromagnetic Lenses - Condenser lens• Aperture• Specimen stage-1. Single-tilt 2. Double-tilt• Vacuum system• Scanning coils• Detectors-1. BF 2.ADF 3.HAADF
![Page 16: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/16.jpg)
Source formation
• The STEM consists of an emission source tungsten filament, or a lanthanum hexaboride
• High voltage source (typically 100-300kV)
• Electrons emit by field emission.
![Page 17: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/17.jpg)
Vacuum system
• STEM is evacuated to low pressure 10^ -4 Pa• It consists of multiple pumping systems and
air locks.• Low or roughing vacuum is achieved with
either rotary vacuum pump or diaphram pumps
• For low vacuum turbomolecular pumps are connected to the chamber
• Gate valve: for different vacuum levels in specific areas(10^-4 to 10^-7 Pa)
![Page 18: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/18.jpg)
V1 V2
Field emission
Electromagnetic Lenses
Aperture Specimen stage
mesh
![Page 19: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/19.jpg)
Specimen holder
![Page 20: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/20.jpg)
Sami-Ullah
![Page 21: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/21.jpg)
Specimen Preparation
• Preparation done in two steps• Pre-Thinning: Reducing the thickness to about 0.1mm• Final Thinning: Reducing the thickness to about 100nminvolveIon MillingElectrolytic ThinningUltramicrotomy
![Page 22: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/22.jpg)
Ion Milling
• Uses a beam of energetic ions to bombard specimen surfaces to reduce the thickness by knocking atoms out of a specimen
• General procedurea) Dimple grindingb) ion milling ion beam of 1–10 keV
bombarded specimen is placed in the
center at an angle of 5-30◦
![Page 23: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/23.jpg)
Electrolytic Thinning
• Reducing specimen thickness to 100nm
• General procedureA specimen placed in
an electrochemical cell as anode
A suitable reduce specimen thickness
Common technique is jet polishing
Electrolytic thinning completed in 3–15 minutes.
![Page 24: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/24.jpg)
Ione milling
Electrolytic thinning
Ultramicrotomy
![Page 25: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/25.jpg)
M Junaid Anjum
![Page 26: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/26.jpg)
Modes
• Transmitted electrons that leave the sample at relatively low angles with respect to the optic axis(bright field (BF).)
• Transmitted electrons that leave the sample at relatively high angles with respect to the optic axis(annular dark field (ADF).)
• High Angle ADF (HAADF) collects the highly scattered Z-contrast beam
![Page 27: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/27.jpg)
Image formation
• BF-STEM images are equivalent to TEM (reciprocity principle).
• Produced Bragg disks hitting the detector
• Give the bright field or phase signal
![Page 28: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/28.jpg)
Image formation
Bright field STEM image of Au particles on a carbon film
![Page 29: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/29.jpg)
ADF images
• Electrons which have scattered to high angles are collected
• Images contain Bragg diffraction
![Page 30: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/30.jpg)
HAADF images
• Two (out of several more) ways to simulate HAADF-STEM images are
• Incoherent Imaging Model:The Image is the convolution of object
potential and probe intensity.Iimage (r )= Iprob (r ) V2proj (r )
• Multiple Scattering Image Simulation:the frozen phonon approximation.
![Page 31: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/31.jpg)
HAADF better Z-contrast than BF
• HAADF is much less sensitive to local diffraction conditions than BF.
• Its sensitivity mainly to the atomic number
![Page 32: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/32.jpg)
Bright and dark field STEM image of Au particles on a carbon film
![Page 33: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/33.jpg)
Why use STEM?•For DF imaging the annular detector collects more electrons than
an aperture.
•STEM ADF images are less noisy then TEM DF images as no lenses
are used to form them.
•Contrast in STEM images is greater than standard DF images.a) b) c)
• Comparison of TEM DF and STEM ADF images of the same
sample shows clear contrast difference
![Page 34: Scanning transmission electron microscope](https://reader036.vdocuments.mx/reader036/viewer/2022081721/554a55b5b4c9054b328b4b0f/html5/thumbnails/34.jpg)
THANK YOU