savier canard

Upload: sattar-al-jabair

Post on 03-Jun-2018

240 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/12/2019 Savier Canard

    1/41

    Some notes about

    Comparing GU & Savier airfoil equipped half canardIn S4 wind tunnel (France)

    Matthieu Scherrer

    Adapted from Charlie Pujo & Nicolas Gorius work

  • 8/12/2019 Savier Canard

    2/41

    Contents

    1 Test conditions 3

    1.1 S-4 Wind-tunnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

    1.2 The team . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    1.3 The tested canards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    1.4 Limitation : a comparison work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    2 Qualitative work : flow visualization 5

    2.1 Wool string visualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    2.2 Laser flow visualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    2.3 Oil flow visualization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    2.4 Visualization report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    3 Quantitative work (1/2) : polar measurements 7

    3.1 Data for comparing VariEze Canard equipped with GU and Savier airfoil . . . . . . . . . . . . . 7

    3.1.1 Canard equipped with GU airfoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    3.1.2 Canard equipped with Savier airfoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    3.1.3 Comparison of canards equipped with GU and Savier airfoil . . . . . . . . . . . . . . . . . 16

    3.2 3D visualisation of lift coefficient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    3.2.1 Canard equipped with GU airfoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    3.2.2 Canard equipped with Savier airfoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    3.3 Effect of wetted surface (rain) and transition on canard equipped with Savier Airfoil . . . . . . 25

    4 Quantitative work (2/2) : extrapolation from polar measurements 29

    4.1 Extrapolated data for airfoils alone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    4.2 Data adapted to flight condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    4.2.1 Result of in flight measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    4.2.2 Comparison of GU and Savier airfoil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    5 Conclusion 41

    2

  • 8/12/2019 Savier Canard

    3/41

    Chapter 1

    Test conditions

    1.1 S-4 Wind-tunnel

    The S-4 wind tunnel used to be a commercial low speed wind tunnel until three years ago. Now propertyof ENSICA school since two years, it is used in a pedagogic way, for studies realized by student. But themeasurement equipment is still the original high quality equipment.

    Figure 1.1: S4 wind tunnel elliptic test section.

    The main data are :

    Elliptic free test section 2x3m.

    Speed between 10 and 40m/s.

    Canard mounted on three mast, with 6 axis measurement (only 3 used).

    Laser and UV light equipment for flow visualisation or measurement.

    Camera and light for filming each test.

    3

  • 8/12/2019 Savier Canard

    4/41

    1.2 The team

    This study was conducted as a pedagogic project (PIR) for two French SUPAERO young students : Charlie

    Pujo and Nicolas Gorius. they produced a (French) report, highlighting some of the main points observethroughout this study.

    Figure 1.2: The full team within test section.

    This project was initiated by Fabrice Claudel, helped by Patrick Lefebvre. The new canard was buildaccording to Klaus Saviers work and drawings.The study was directed by Paul Claude Dufour and Matthieu Scherrer.

    1.3 The tested canards

    Full size half-canards were tested into the wind tunnel. A small flat plate was put to create a symmetry axis.

    Both GU and Savier canards were similarly intalled in the wind tunnel.

    The wind speed was set to the maximum available, that is 40m/s. this will gives correct values of Reynoldsnumber for the low speed enveloppe of the VariEze, but too low for high speed.

    1.4 Limitation : a comparison work

    Here are some limitation about the work that was done.

    Only half a canard, without fuselage influence, was tested. The symmetry plane was not a perfect one.

    It was possible to measure and then subtract only a part of drag created by the fittings and attachmentdevice.

    As a consequence, the absolute value concerningCd0 and Clmaxmight not be accurate. But the fittings andattachment system were similar for both canard.This work is then a Comparison of the two canards.

  • 8/12/2019 Savier Canard

    5/41

    Chapter 2

    Qualitative work : flow visualization

    There were many way available to visualize the airflow over the canards. We tried characterize the canards witheach of those.

    NB : this was done partly in a pedagogical objective.

    2.1 Wool string visualization

    It was possible to move a wool string all aver the canard. Then functionning of the flap gap or wing tip vortexcould be observed.

    2.2 Laser flow visualization

    Wing tip flow was through laser tomography. A laser beam was split into a plan, and smoke was send. Thenthe wing tip vortex could be studied.

    There as no qualitative difference in aspect between the vortex of the two different canard.

    2.3 Oil flow visualization

    The oil flow visualization were the most interesting qualitative testing. It was possible to visualize and analyzethe laminar to turbulent transition on the extrados, and the quality of this transition.Shortly summed up, we may say :

    GU Canard Savier canardCl 0.5, no flap defl.

    Position of transition 60-65% 40%Laminar bubble wide (10% of chord) & thick (oil) short (3-4% of chord) & thin (no oil)

    Cl 1.2, no flap defl.Position of transition - 25%

    Laminar bubble - disappearing

    Intrados was not much observed.

    It was tried to trip the laminar boundary layer to turbulent on the GU airfoil, to kill the laminar bubble.This does work with quite thick scotch tape.

    5

  • 8/12/2019 Savier Canard

    6/41

    Other visualization were made to observed the wing tip flow. The path of the vortex wing tip can be clearlyseen.

    2.4 Visualization report

    Each visualization run was fully filmed.

    A 3 minutes sequences was assembled by Charlie Pujo and Nicolas Gorius, and compressed as an *.AVIfilm. It represents the best visualization report. Indeed, photograph are too static to represents properly thosevisualisations.This *.AVI film (50 Mo) might be available on the internet or on an ftp site (to be defined).

    I will also issue a compilation of some of the photographs taken during those visualization trial.

  • 8/12/2019 Savier Canard

    7/41

    Chapter 3

    Quantitative work (1/2) : polarmeasurements

    3.1 Data for comparing VariEze Canard equipped with GU andSavier airfoil

    Here are displayed the results of measurement on the two canards. Three axis were measured :

    Lift force values.

    Drag force values.

    Pitching moment values, at 25% of chord (that aerodynamical center).

    First are presented values for GU canard, and then for Savier canard. Finally comparison are made and someconclusion drawn.

    7

  • 8/12/2019 Savier Canard

    8/41

    3.1.1 Canard equipped with GU airfoil

    Lift coefficient

    10 5 0 5 10 15 20 251

    0.5

    0

    0.5

    1

    1.5

    2

    2.5GU Airfoil

    Alpha (deg)

    Cl

    (

    )

    Flap setting27deg15deg7.5deg0 deg7.5deg15deg24deg

    Figure 3.1: Lift coefficient vs incidence. Note the tricky hysteresis behavior for high flap deflec-tion.

  • 8/12/2019 Savier Canard

    9/41

    Drag polar

    0 0.1 0.2 0.3 0.4 0.5 0.61

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    GU Airfoil

    Alpha (deg)

    Cl

    (

    )

    Flap setting27deg15deg7.5deg0 deg7.5deg15deg24deg

    Figure 3.2: Lift coefficient vs drag coefficient.

  • 8/12/2019 Savier Canard

    10/41

    Drag polar (detail)

    0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1

    0.4

    0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    GU Airfoil

    Cd()

    Cl

    (

    )

    Flap setting27deg15deg7.5deg0 deg7.5deg15deg24deg

    Figure 3.3: Lift coefficient vs drag coefficient, detailed around minimum drag.

  • 8/12/2019 Savier Canard

    11/41

    Moment coefficient (at 25% chord)

    10 5 0 5 10 15 20 250.35

    0.3

    0.25

    0.2

    0.15

    0.1

    0.05

    0

    0.05

    0.1

    GU Airfoil

    Alpha (deg)

    Cm

    (

    )

    Flap setting27deg15deg7.5deg0 deg7.5deg15deg24deg

    Figure 3.4: Moment coefficient vs incidence, detailed around minimum drag.

  • 8/12/2019 Savier Canard

    12/41

    3.1.2 Canard equipped with Savier airfoil

    Lift coefficient

    10 5 0 5 10 15 20 25 30 351

    0.5

    0

    0.5

    1

    1.5

    2

    2.5Savier Airfoil

    Alpha (deg)

    Cl

    (

    )

    Flap setting15deg10deg8deg3deg0deg15deg30deg

    40deg

    Figure 3.5: Lift coefficient vs incidence. Contrary to GU airfoil, there is no hysteresis behaviorfor high flap deflection.

  • 8/12/2019 Savier Canard

    13/41

    Drag polar

    0 0.1 0.2 0.3 0.4 0.5 0.61

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    Savier Airfoil

    Cd ()

    Cl

    (

    )

    Flap setting15deg10deg8deg3deg0deg15deg30deg40deg

    Figure 3.6: Lift coefficient vs drag coefficient.

  • 8/12/2019 Savier Canard

    14/41

    Drag polar (detail)

    0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1

    0.4

    0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    Savier Airfoil

    Cd ()

    Cl

    (

    )

    Flap setting15deg10deg8deg3deg0deg15deg30deg40deg

    Figure 3.7: Lift coefficient vs drag coefficient, detailed around minimum drag.

  • 8/12/2019 Savier Canard

    15/41

    Moment coefficient (at 25% chord)

    10 5 0 5 10 15 20 25 30 35

    0.3

    0.25

    0.2

    0.15

    0.1

    0.05

    0

    0.05

    0.1

    Savier Airfoil

    Alpha (deg)

    Cm

    (

    )

    Flap setting15deg10deg8deg3deg0deg15deg30deg40deg

    Figure 3.8: Moment coefficient vs incidence.

  • 8/12/2019 Savier Canard

    16/41

    3.1.3 Comparison of canards equipped with GU and Savier airfoil

    We shall now plot the Cl, Cd andCm values on the same graphics.

    Some results Here are the main results concerning lift :

    The Savier canard can reach the same Cl range as GU canard, including very high values for Clmax.

    This Cl range is obtained for different flap setting and incidence for GU or Savier canard. Hence theimportance of a correct setting of the rigging angle on the fuselage.

    The Savier has apparently no problem with hysteresis for high flap deflection, comparing to the GU. Itcan be hoped that Savier canard might not present tricky behavior with high loading as GU sometimedoes.

    Then some results concerning drag :

    The Savier canard has a lower minimum drag coefficient than GU canard. This corresponds to lower Cdat low loads, that is high speed configuration.

    Minimum drag for the Savier canard is reached for -3o flap defelction

    The polar for Savier canard is more rounded and closed than for GU, than is Cd gets higher for theSavier than for the GU when its load gets higher.

    My two cents about this : my impression is that Savier canard is more adapted to high speed, even if lesslaminar, and then would have less Clmax with no flap deflection.But thanks to a carefully design slat, it can reach as high Clmax as GU canard , while being more performingfor high speed.

  • 8/12/2019 Savier Canard

    17/41

    Lift coefficient

    10 5 0 5 10 15 20 25 30 35

    1

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    GU & Savier Airfoil

    Alpha (deg)

    Cl

    (

    )

    GU airfoil

    Savier airfoil

    27

    15

    7.5

    0

    7.5

    15

    24

    15

    108

    3

    0

    15

    30

    40

    Figure 3.9: Lift coefficient vs incidence. Contrary to GU, Savier airfoil has no hysteresis behaviorfor high flap deflection. Cl slope is more regular for Savier than for GU.

  • 8/12/2019 Savier Canard

    18/41

    Drag polar

    0 0.1 0.2 0.3 0.4 0.5 0.61

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    GU & Savier Airfoil

    Cd ()

    Cl

    (

    )

    GU airfoil

    Savier airfoil

    Figure 3.10: Lift coefficient vs drag coefficient. Effect of flap deflection may seem higher forSavier airfoil.

  • 8/12/2019 Savier Canard

    19/41

    Drag polar (detail)

    0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1

    0.4

    0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    GU & Savier Airfoil

    Cd ()

    Cl

    (

    )

    GU airfoil

    Savier airfoil

    Figure 3.11: Lift coefficient vs drag coefficient, detailed around minimum drag. Minimum dragis smaller for Savier than for GU airfoil.

  • 8/12/2019 Savier Canard

    20/41

    Moment coefficient (at 25% chord)

    10 5 0 5 10 15 20 25 30 35

    0.3

    0.25

    0.2

    0.15

    0.1

    0.05

    0

    0.05

    0.1

    GU & Savier Airfoil

    Alpha (deg)

    Cm

    (

    )

    24

    27

    15

    7.5

    0

    7.5

    15

    15

    10

    8

    3

    0

    15

    30

    40

    Figure 3.12: Moment coefficient vs incidence. Absolute values ofCm0 are smaller for Savier thanfor GU airfoil.

  • 8/12/2019 Savier Canard

    21/41

    3.2 3D visualisation of lift coefficient

    3.2.1 Canard equipped with GU airfoil

    Cl according to incidence and flap setting

    10 5 0

    5 10 15 20

    25 30 3520

    0

    20

    40

    1

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    Incidence (deg)

    GU Airfoil

    Flap setting (deg)

    Figure 3.13: Lift coefficient as a function of both incidence and flap setting. Tri-dimensionnalview.

  • 8/12/2019 Savier Canard

    22/41

    Cl according to incidence and flap setting

    10 5 0 5 10 15 20 25 30 3530

    20

    10

    0

    10

    20

    30

    40

    GU Airfoil

    Incidence (deg)

    Flap

    setting

    (deg)

    0.5

    0.5

    0

    0

    0

    0

    0.25

    0.25

    0.25

    0.25

    0.5

    0.5

    0.5

    0.5

    0.5

    0.5

    0.75

    0.75

    0.750.75

    0.75

    0

    .75

    1

    1

    1

    1

    1

    1.25

    1.25

    1.25

    1.25

    1.5

    1.5

    1.5

    1.5

    1.51.75

    1.751.7

    5

    1.75 1.8

    1.81.8

    2

    Figure 3.14: Lift coefficient as a function of both incidence and flap setting. Levels view.

  • 8/12/2019 Savier Canard

    23/41

    3.2.2 Canard equipped with Savier airfoil

    Cl according to incidence and flap setting

    10 5 0 5

    10 15 20 25

    30 3520

    0

    20

    40

    1

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    Incidence (deg)

    Savier Airfoil

    Flap setting (deg)

    Figure 3.15: Lift coefficient as a function of both incidence and flap setting. Tri-dimensionnalview.

  • 8/12/2019 Savier Canard

    24/41

    Cl according to incidence and flap setting

    10 5 0 5 10 15 20 25 30 3530

    20

    10

    0

    10

    20

    30

    40

    Savier Airfoil

    Incidence (deg)

    Flap

    setting

    (deg)

    0

    0

    0

    0

    0.25

    0.25

    0.25

    0.25

    0.5

    0.5

    0.5

    0.5

    0.5

    0.5

    0.75

    0.75

    0.750.75

    0.75

    0.75

    1

    1

    1

    1

    1

    1

    1

    1

    1.25

    1.25

    1.25

    1.2

    5

    1.2

    5

    1.2

    5

    1.25

    1.25

    1.5

    1.5

    1.5

    1.5

    1.5

    1.5

    1.75

    1.7

    5

    1.7

    5

    1.75

    1.8

    1.

    8

    1.

    8

    1.8

    2 2

    Figure 3.16: Lift coefficient as a function of both incidence and flap setting. Levels view.

  • 8/12/2019 Savier Canard

    25/41

    3.3 Effect of wetted surface (rain) and transition on canard equippedwith Savier Airfoil

    Artificial transition was created by carborandum located at 5% chord.

    Wetted surface referred to measurements with visualization oil on the canard.

    One conclusion is that if transition occurred early, performance is really affected. But it seems Savier airfoilis resistant to wetted surface, since wetted surface did not seem to create transition. This point should bedetailed further.

  • 8/12/2019 Savier Canard

    26/41

    Effect of rain & transition on lift coefficient

    10 5 0 5 10 15 20 25 30 35

    0.8

    0.6

    0.4

    0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    Savier Airfoil

    Alpha (deg)

    Cl

    (

    )

    Natural airfoil

    Wetted extr.

    Transition extr. 5%

    Figure 3.17: Lift coefficient vs incidence. Savier airfoil seems to be not really hurt by wettedsurface, whereas genuine transition reduced greatly maximum lift.

  • 8/12/2019 Savier Canard

    27/41

    Effect of rain & transition on drag polar

    0 0.05 0.1 0.15 0.2 0.25 0.3 0.350.8

    0.6

    0.4

    0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    Savier Airfoil

    Cd()

    Cl

    (

    )

    Natural airfoil

    Wetted extr.

    Transition extr. 5%

    Figure 3.18: Lift coefficient vs drag coefficient.

  • 8/12/2019 Savier Canard

    28/41

    Effect of rain & transition on moment coefficient

    10 5 0 5 10 15 20 25 30 35

    0.01

    0

    0.01

    0.02

    0.03

    0.04

    0.05

    0.06

    0.07

    0.08

    0.09

    Savier Airfoil

    Alpha (deg)

    Cm

    (

    )

    Natural airfoil

    Wetted extr.

    Transition extr. 5%

    Figure 3.19: Moment coefficient vs incidence.

  • 8/12/2019 Savier Canard

    29/41

    Chapter 4

    Quantitative work (2/2) :extrapolation from polar measurements

    From raw data, some calculation work can be done for extrapolating some complementary data.

    At first, the part of the airfoil within drag can be extracted.

    Then, we can look carefully the wind tunnel data on each functioning point that is encountered in steadyflight.

    29

  • 8/12/2019 Savier Canard

    30/41

    4.1 Extrapolated data for airfoils alone

    In short, drag measured for the half canard can be split into :

    Mounting drag CdMount, that is drag causes by the fitting device into the wind tunnel.

    Airfoil drag CdAirf

    Induced dragCdi

    Cd= CdMount+ CdAirf+ Cdi (4.1)

    Assuming the left plate is a correct plan of symmetry, we can say that the effective aspect ratio is about= 5. This is coherent with the Cl slope measured. Then the induced drag can be expressed as Cdi =

    1

    Cl

    2,and subtracted from the total drag coefficient.

    Then we can compare airfoil, since Mounting drag CdMount is comparable for both half canards.

    NB : so keep in mind that the minimum drag values Cd0 plotted contains CdMount, that is fittings andattachment system. So that they are not genuine airfoil Cd0.

  • 8/12/2019 Savier Canard

    31/41

    Drag polars

    0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.21

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    GU Airfoil

    Alpha (deg)

    Cl

    (

    )

    Flap setting27deg15deg7.5deg0 deg7.5deg15deg24deg

    Figure 4.1: Lift coefficient vs drag coefficient, for airfoil only.

  • 8/12/2019 Savier Canard

    32/41

    Drag polars

    0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.21

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    Savier Airfoil

    Alpha (deg)

    Cl

    (

    )

    Flap setting15deg10deg8deg3deg0deg15deg30deg40deg

    Figure 4.2: Lift coefficient vs drag coefficient, for airfoil only.

  • 8/12/2019 Savier Canard

    33/41

    Drag polars comparison

    0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.21

    0.5

    0

    0.5

    1

    1.5

    2

    2.5

    GU & Savier Airfoil

    Cd()

    Cl

    (

    )

    GU airfoil

    Savier airfoil

    Figure 4.3: Comparison of drag polars for airfoils only. Savier Airfoil has a less laminar behavior(more rounded polar), but lower Cdmin.

  • 8/12/2019 Savier Canard

    34/41

    4.2 Data adapted to flight condition

    An attempt to get the effective in flight parameters over the canards was made. Every parameter were not

    known, but this is a good start for the comparison of both canard.Indeed, wind tunnel data have to be treated to be used with the different parameters

    Measurement of flap deflection and fuselage attitude was installed into three aircraft (F-PYHR (Saviercanard), F-PYOP (GU Canard), F-PYSM (GU Canard)).

    Similar measurements were made on the three aircraft to reduce scatter effect.

    Measurements were made for aircraft wing-loadings close to each other.

    Data were collected at first on a steady, constant attitude path, for basic values of incidence and flapdeflection. Then some measurements were also made with constant bank and altitude, for higher load onthe canard.

    From measurements, calculations were made to get the effective aerodynamic incidence on the canard,influenced by the wing.

    Some interpolations of the wind tunnel results were made to get the exact functioning parameters of thecanards within the collected data.

    We should keep in mind the following points :

    A weak point of this study is that we could not get precise CG location for each aircraft. CG locationinfluences canard load, hence its performance. We supposed that empty CG location were comparable onthe different aircraft, according to the building plan.

    It is a pity we could not make the measurements of both canards on the same aircraft. This will be soon

    possible on F-PYIB (Savier & GU canard) which is currently grounded, and this study will be released.

    Reynolds number for wind tunnel data corresponds to low speed.

    Some results

    If you look only on the effective drag polar for the canard of trimmed aircraft, Savier Canard has a lowerdrag coefficient only for low Cl values.

    If you plotCd as a function of speed of the trimmed aircraft, Savier Canard has lower drag coefficient fora larger speed domain.

    If you plot value of the drag force, as a function of speed of the trimmed aircraft, Savier Canard saves

    really quite a lot drag at high speed. This is caused partly to the magnifying effect ofV2 value.

  • 8/12/2019 Savier Canard

    35/41

  • 8/12/2019 Savier Canard

    36/41

    Calculated effective Cl for the canard of trimmed aircraft according to speed(Based on in flight measurement)

    100 150 200 250 300 3500.2

    0.4

    0.6

    0.8

    1

    1.2

    1.4

    1.6

    V (km/h)

    Cl

    (

    )

    Resulting GUResulting Savier

    Figure 4.5: Cl for trimmed aircraft vs speed, on aircraft equipped with both canard.

  • 8/12/2019 Savier Canard

    37/41

    4.2.2 Comparison of GU and Savier airfoil

    EffectiveCl for the canard of trimmed aircraft

    (Calculation based on in flight measurement plus wind tunnel interpolation)

    10 5 0 5 10 15 20 25 30 350.5

    0

    0.5

    1

    1.5

    2

    Incidence (deg)

    Cl

    (

    )

    Resulting GUResulting Savier

    Figure 4.6: Cl for trimmed aircraft vs incidence and flap setting, as put on the wind tunnelmeasurement.

  • 8/12/2019 Savier Canard

    38/41

    Effective drag polar for the canard of trimmed aircraft(Calculation based on in flight measurement plus wind tunnel interpolation)

    0.05 0.1 0.15 0.2 0.250

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    1.4

    1.6

    Cd()

    Cl

    (

    )

    Resulting GUResulting Savier

    Figure 4.7: Cl vs Cd for the canard of trimmed aircraft, interpolated from wind tunnel measure-ment.

  • 8/12/2019 Savier Canard

    39/41

    Drag coefficient for the canard of trimmed aircraft according to speed(Calculation based on in flight measurement plus wind tunnel interpolation)

    100 150 200 250 300 3500.02

    0.04

    0.06

    0.08

    0.1

    0.12

    0.14

    0.16

    0.18

    V (km/h)

    Cd(

    )

    Resulting GUResulting Savier

    Figure 4.8: Cd for the canard of trimmed aircraft vs speed, interpolated from wind tunnel mea-surement. Savier airfoil equipped canard has higher drag coefficient for intermediate speed,whereas at low and high speed Cd is lower.

  • 8/12/2019 Savier Canard

    40/41

    Drag values in Newton (N) for the canard of trimmed aircraft according to speed(Calculation based on in flight measurement plus wind tunnel interpolation)

    100 150 200 250 300 35060

    70

    80

    90

    100

    110

    120

    130

    V (km/h)

    Drag(N)

    Resulting GUResulting Savier

    Figure 4.9: Drag values in Newton (N) for the canard of trimmed aircraft vs speed, interpolatedfrom wind tunnel measurement. Drag value is 1/4 lower for the Savier Canard at high speed.

  • 8/12/2019 Savier Canard

    41/41

    Chapter 5

    Conclusion

    This paper has presented the measurements made in a pedagogical project, performed by french students.In this summary, experimental parameters were described. Then presentation of raw data were performed.Some extrapolation were also made to use the raw data in in flight conditions.From those data, others work could be done.

    The measurement chain was top quality, and we are confident about the measurements that were made. Weare really happy to have benefit from S-4 wind tunnel.The main regret we have is that the wind tunnel could not produce more than 40m/s. It would have been niceto measure hinge moment on the flap, since reduction allowed by Savier Canard is a key point observed in flight.

    We hope this work will help being confident about the Savier Canard.