rotary positive displacement twin lobe & tri lobe …akashblowers.com/users/20160121125128_cata...

4
Rotary Positive Displacement Twin Lobe & Tri Lobe Compressors (Roots Blowers) |Product Catalog Vacuum Booster MVR System Acoustic Hood

Upload: vantruc

Post on 27-Jul-2018

270 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Rotary Positive Displacement Twin Lobe & Tri Lobe …akashblowers.com/users/20160121125128_cata design.pdf · Rotary Positive Displacement Twin Lobe & Tri Lobe Compressors (Roots

Rotary Positive Displacement Twin Lobe& Tri Lobe Compressors (Roots Blowers)

| P r o d u c t C a t a l o g

Vacuum Booster MVR SystemAcoustic Hood

Page 2: Rotary Positive Displacement Twin Lobe & Tri Lobe …akashblowers.com/users/20160121125128_cata design.pdf · Rotary Positive Displacement Twin Lobe & Tri Lobe Compressors (Roots

1

23

4

56

CASINGAll AKASH blower units are single-piece construction and precision machined cast iron, with ribs for strength and consistent thermal behavior

BEARINGSAll AKASH blower units are using SKF / FAG bearings with long life, anti-friction type very with machine.

TIMING GEARSForged steel gears with hardened and ground teeth to reduced vibrations and ensures accurate rotor to rotor timing for smooth and efcient operation.

SEALLow-wear non-contacting, labyrinth-type seals ensure performance and long life.

SHAFTSImpeller shafts are alloy steel forgings that allow higher operating pressures and rotation speeds.

ROTORSMade from cast iron or S.G. iron with stiff design or maximum life. By CNC and 3D machinery control to ensure the highest performances, providing with trouble-free performance and durability.

ABOUT AKASH :With the expertise earned from 40+ years of experience, AKASH started making a difference in manufacturing superior Industrial Machinery since 2009 by developing : High quality Two Lobe & Three Lobe Roots Type Blowers & Boosters

WE AIM TO :Ensure product stability and maintain standardized production thereby making sure that we remain at per with developments and principles.

Our hard and sincere efforts over the past years have

driven us ahead in the Indian market, earning Customer

Satisfaction and Credibility. At AKASH, we manufacture

and provide efficient & timely support to our clients with

the zeal to excel. We make a self-commitment to offer

our customers-Best Products and Services. We believe

that our reputation for Reliability, Excellent Services and

Quality Products has helped us grow very fast in India in

the area of Blowers, Boosters and Vacuum pumps.

OUR VALUES :

Passion to Win & Be-The-Best at whatever we do.

Integrity knowing what is right and acting responsibly

with our clients, colleagues and community.

Innovation anticipating our clients' needs

Dedication for unparalleled quality and proven success

Guidance serving our client with experienced guidance

regarding their actual needs

WHY AKASH :

Clients choose AKASH when they want to work in

partnership – our goodwill is based on the trust of our

clients earned by our passion to deliver the best.

Low-noise Blower

Oil Free Air

Long Life, Stable Performance

User-friendly Product

Low Maintenance

Compact Size

Having Specialization in :

We Adhere to : Competitive prices, efficiency, sturdiness,

innovation, durability and easy maintenance.

1

2

3

4

5

6

Page 3: Rotary Positive Displacement Twin Lobe & Tri Lobe …akashblowers.com/users/20160121125128_cata design.pdf · Rotary Positive Displacement Twin Lobe & Tri Lobe Compressors (Roots

Pe

rfo

rma

nce

Da

ta (

Air

Co

ole

d B

low

ers)

1200 4025 21.97 3882 37.95 3771 53.92 3678 69.89 3596 85.87 3522 101.84 3454 117.81

1440 4900 26.37 4756 45.54 4646 64.70 4553 83.87 4471 103.04 4397 122.21 4328 141.38

1000 4217 22.03 4033 39.05 3891 56.08 3772 73.10 3667 90.13 3573 107.15

1200 5149 26.43 4965 46.86 4824 67.29 4705 87.72 4600 108.15 4505 128.59

1440 6268 31.72 6083 56.23 5942 80.75 5823 105.27 5718 129.79 5623 154.30

1000 4953 25.00 4737 45.00 4571 64.99 4431 84.99 4308 104.99 4196 124.99

1200 6048 30.00 5831 53.99 5666 77.99 5526 101.99 5402 125.99

1440 7361 36.00 7145 64.79 6979 93.59 6840 122.39 6716 151.18

Note : 1. The above ra�ngs are based on inlet air temperature of 104 D F, ambient pressure 1 kg/cm2, specific gravity of 1.0.

2. Performance tes�ng as per BS 1571, part-II

3. All specifica�ons are subject to change without no�ce.

AB-1020

AB-1024

350

350

MODEL IN./OUT. SPEED

(MM) (RPM) M3/HR BHP M3/HR BHP M3/HR BHP M3/HR BHP M3/HR BHP M3/HR BHP M3/HR BHP

960 30 0.67 27 0.79 24 0.96 21 1.13

1440 50 0.76 45 0.96 41 1.20 38 1.43

960 48 0.41 39 0.67 32 0.92 26 1.18 21 1.43

1200 65 0.52 56 0.84 49 1.16 44 1.47 38 1.79

1440 83 0.62 74 1.00 67 1.39 61 1.77

1000 77 0.73 67 1.10 60 1.47 53 1.85 48 2.22 42 2.59 38 2.96

1300 108 0.95 98 1.43 90 1.92 84 2.40 78 2.88 73 3.37 68 3.85

1600 138 1.17 128 1.76 121 2.36 114 2.95 109 3.55 103 4.14 99 4.74

1000 124 0.90 114 1.45 106 1.99 99 2.54 94 3.08 88 3.63 83 4.17

1300 169 1.18 159 1.88 151 2.59 144 3.30 138 4.01 133 4.72 128 5.43

1600 214 1.45 203 2.32 196 3.19 189 4.06 183 4.93 178 5.81 173 6.68

1000 208 1.59 182 2.58 162 3.57 145 4.56

1300 290 2.07 263 3.36 243 4.64 227 5.93

1600 371 2.54 345 4.13 325 5.71

1000 181 1.82 163 2.63 150 3.45 138 4.27 128 5.09 119 5.90 111 6.72

1300 248 2.36 231 3.42 217 4.49 206 5.55 195 6.61 186 7.67 178 8.74

1600 315 2.91 298 4.22 284 5.52 273 6.83 263 8.14 253 9.45 245 10.75

1000 233 2.05 210 3.11 193 4.16 178 5.21 165 6.26 154 7.32 143 8.37

1300 320 2.67 297 4.04 279 5.40 265 6.77 252 8.14 240 9.51 229 10.88

1600 406 3.28 383 4.97 366 6.65 351 8.34 338 10.02 326 11.70 316 13.39

1000 326 2.47 295 3.95 270 5.42 250 6.89 231 8.37 215 9.84

1200 407 2.97 375 4.74 351 6.50 330 8.27 312 10.04 296 11.81

1440 504 3.56 472 5.68 448 7.81 427 9.93 409 12.05

1000 450 3.30 409 5.30 378 7.30 352 9.30 329 11.30

1200 559 3.96 519 6.36 487 8.76 461 11.16

1440 690 4.75 650 7.63 619 10.51 593 13.39

1200 291 2.46 268 3.73 251 4.99 236 6.25 223 7.52 211 8.78 200 10.04

1400 348 2.87 326 4.35 308 5.82 294 7.29 281 8.77 269 10.24 258 11.71

1600 406 3.28 383 4.97 366 6.65 351 8.34 338 10.02 326 11.70 316 13.39

1000 453 3.04 409 5.09 375 7.13 346 9.17 321 11.22 298 13.26 277 15.30

1000 MMWG 2000 MMWG 3000 MMWG 4000 MMWG 5000 MMWG 6000 MMWG 7000 MMWG

AB-57

AB-59/

AQUA-B

EXPO

40

40

40

AB-325

AB-42

AB-44

AB-47/

AQUA-A

AB-53

AB-55

AB-315

80

80

80

80

80

100

80

1300 620 3.96 576 6.61 542 9.27 514 11.92 489 14.58 466 17.24 445 19.89

1600 788 4.87 744 8.14 710 11.41 682 14.68 656 17.94 634 21.21 613 24.48

1000 605 3.73 546 6.46 501 9.19 462 11.92 429 14.65 398 17.38 370 20.11

1300 829 4.85 770 8.40 725 11.95 687 15.50 653 19.05 623 22.60 595 26.15

1600 1053 5.97 994 10.34 949 14.71 911 19.07 877 23.44 847 27.81 819 32.18

1000 1016 5.62 925 10.14 854 14.66 795 19.18 743 23.70

1300 1387 7.31 1296 13.18 1225 19.06 1166 24.93

1600 1759 8.99 1667 16.22 1597 23.45 1537 30.69

1000 795 4.34 746 7.69 707 11.03 675 14.37 647 17.72 621 21.06 598 24.40

1300 1070 5.65 1020 9.99 982 14.34 950 18.68 922 23.03 896 27.38 872 31.72

1600 1344 6.95 1295 12.30 1257 17.65 1224 23.00 1196 28.35 1171 33.70 1147 39.04

1000 994 5.18 932 9.36 884 13.54 844 17.72 809 21.90 777 26.07 747 30.25

1300 1337 6.73 1275 12.17 1228 17.60 1187 23.03 1152 28.46 1120 33.90 1091 39.33

1600 1681 8.29 1618 14.97 1571 21.66 1531 28.35 1495 35.03 1463 41.72 1434 48.41

1000 1292 6.43 1211 11.86 1149 17.29 1097 22.72 1051 28.15 1009 33.58 971 39.01

1300 1738 8.36 1657 15.42 1595 22.48 1543 29.53 1497 36.59 1455 43.65 1417 50.71

1600 2183 10.29 2103 18.97 2041 27.66 1989 36.35 1943 45.04 1901 53.72

1000 1691 8.61 1585 15.71 1504 22.82 1436 29.93 1375 37.04

1200 2080 10.33 1974 18.86 1893 27.39 1825 35.92

1500 2664 12.91 2558 23.57 2477 34.23 2409 44.89

1000 1435 9.79 1373 15.59 1324 21.38 1284 27.18 1248 32.97 1216 38.77 1186 44.56

1200 1752 11.75 1690 18.71 1642 25.66 1601 32.62 1566 39.57 1533 46.52 1504 53.48

1440 2133 14.10 2071 22.45 2023 30.79 1982 39.14 1946 47.48 1914 55.83 1884 64.17

1000 1914 11.73 1830 19.45 1766 27.18 1712 34.91 1664 42.63 1621 50.36

1200 2337 14.07 2253 23.34 2189 32.62 2135 41.89 2087 51.16 2044 60.43

1440 2844 16.89 2761 28.01 2697 39.14 2643 50.27 2595 61.39 2552 72.52

1000 2392 13.66 2288 23.32 2207 32.97 2140 42.63 2080 52.29

1200 2921 16.39 2816 27.98 2736 39.57 2669 51.16

1440 3555 19.67 3451 33.58 3371 47.48 3303 61.39

1000 2453 14.91 2346 24.81 2264 34.72 2195 44.62 2134 54.53 2079 64.44 2028 74.34

1200 2996 17.89 2889 29.77 2806 41.66 2737 53.55 2676 65.44 2621 77.32 2570 89.21

1440 3647 21.46 3539 35.73 3457 49.99 3388 64.26 3327 78.52 3272 92.79 3221 107.05

1000 3297 18.31 3153 31.62 3042 44.93 2949 58.24 2867 71.56 2793 84.87 2725 98.18

AB-713

AB-717

AB-812

AB-816

AB-67

AB-610

AB-615

AB-78

AB-710

AB-820

AB-1012

AB-1016

150

125

125

150

125

300

150

200

200

250

250

250

Page 4: Rotary Positive Displacement Twin Lobe & Tri Lobe …akashblowers.com/users/20160121125128_cata design.pdf · Rotary Positive Displacement Twin Lobe & Tri Lobe Compressors (Roots

AKASH Blowers Pvt. Ltd.

Water treatment Plated bath HumidifierCleaning of pipe

Example of usage at pressure model

Drying Sand blastDrying lineReversal washing

Spray Paper feed of print machine Transportation of particlesOxygen supply of aquafarm

Example of usage at vacuum model

Food processing Dehydration FilterHeat treatment

Paper feed of print machine

It is used for aeration and the stir in the water treatment plant.

Blower is used to clean of pipe and to supply the coating to piping.

When the electrolyte in the bath is made to circulate for making of plating high-quality, it is necessary to supply air in the bath.Blower is used as the air supply

Blower is used as an air supply of the humidier for static electricity prevention and for making of the indoor humidity constant.

Blower is used for the drying after it is washed. Blower is used to wash the lter etc by reversal ow.

Blower is used for a small-scale drying line. Blower is used as a air supply of the sand blast.

Because neither moisture nor oil are included in the exhalation air, blower is used for the air supply of the spray such as painting.

Blower is used for the Oxygen supply of aquafarm, for the stir. Blower is used also in the aquarium etc.

The exhalation air of blower helps the separation and distribution of paper.

Blower is used for the pneumatic transportation of the pellet of vinyl chloride and polyethylene etc. It is possible to use it by the vacuum method.

Opposite - BSM Company, Near - Plot No. 499, Hanuman Dharam Kanta Road,

Modern Industrial Estate, Part-A, Bahadurgarh, District-Jhajjar, Haryana, India, PIN-124507

Mobile No. : +91 9999 56 4644, 9354 57 5533 / 22 / 12 | Ofce : +91-01276 – 606600

Email : [email protected] | Website : www.akashblowers.com | www.facebook.com/akashblowers

Because neither moisture nor oil are included in the exhalation air, blower is used for the air supply of the spray such as painting.

Blower is used for the Oxygen supply of aquafarm, for the stir. Blower is used also in the aquarium etc.

The exhalation air of blower helps the separation and distribution of paper.

Blower is used for the pneumatic transportation of the pellet of vinyl chloride and polyethylene etc. It is possible to use it by the vacuum method.

When the paper printed with high-speed press is decelerated before it is piled up, the vacuum is used to hold paper in deceleration roller.

The vacuum pump is used to transport soybean, rice, wheat and particle etc.

It is used to pack the perishable foods such as vegetable and meat in the vacuum.

It is used for the vacuum drying.

Vacuum packing of food Vacuum pump for washerof water system

Transportation of particle