risk experts - riskmatrix, beispieldaten · riskmatrix assessment (rating) a very low fire,...

3
2015 Advice: grey fields to be completed manually (others are computed automatically)! V150218 3 * comparison to other occupancies or benchmarking is reasonable only in case of similar risk class! *multilingual selection and weighted rating only availlable in the full version! Risk assessment category Rating Rating criteria Operational risks: occupancy hazards, high pressure, high temperature, chemical reactions A Detection: sensors (fire, gas, ignition sources), alarm management (manual, automatic) A Location: surrounding, neighborhood A Fire water supply: water source, fire water pumps, fire water mains, outdoor hydrant system D Inspections: organization, programs, procedures, mechanical / electrical D Risk management: philosophy, safety organization, safety culture, risk awareness, management KPI's C Rating criteria Warehouse risks: block storage, high rack storage, tank farms B Monitoring: process control, control rooms, server rooms, data processing B External layout: spacing between buildings and units, fire complex separation B Fixed and automatic fire suppression systems: sprinkler, deluge, foam, CO2 D Maintenance / repairs: organisation, programs, procedures, impairment handling, preventive / protective E Hazard analysis: programs (HAZOP), emergency plan, change management 0 Rating criteria Material risks: fire load, flammable liquids, combustible gases, fine dust, explosives D Security: burglary protection, intruder alarm B Internal layout: physical separation within buildings and units, fire area compartmentation E Manual fire fighting systems: hose reel boxes, indoor hydrants, fire monitors, extinguishers B Safety installations control: Inspection and maintenance of fire fighting equipment and safety features C Documentation: fire safety plan, emergency operating procedures, P&Ids C Rating criteria Utilities service risk: electricity, steam, compressed air, heating, cooling, technical gases, IT & EDP B 0 Construction: materials, insulation, fireproofing D Emergency response: Public / plant fire brigade, fulltime (24/7) / voluntary, emergency team, response time, equipment C Workforce: staffing, education, experience, training, contractors D Safety audits: inspection rounds, response to recommendations, incident investigation B Rating criteria Process risk: size of the plant, complexity of processes, capacity, utilization A 0 Leakage control: Drainage, curbing, embankments, spill protection B Isolation and interlocks: Automatic shutdown (ESD), unit isolation means, automatic interlock devices B Safe work practice: Shift handover , work permits, smoking ban, housekeeping, storage practice B Claims handling: claims handling procedures, crisis management team, crisis control room C Rating criteria 0 0 Building and equipment integrity: technical age, operating hours, design codes, state of repair A Special protection: smoke vents, explosion protection, lightning protection, oxygen reduction A Safety at work: safety management, commitment to safety, personnel protection equipment C 0 Risk assessment category Rating Rating criteria Plant configuration, complexity, operation mode C Plant configuration, complexity, operation mode E General: Annual turnover, replacement time, peak periods, market conditions C General: Annual turnover, replacement time, peak periods, market conditions A Earthquake D Earthquake D Rating criteria Proven technology (no prototype), proven parts, reliable design B Proven technology (no prototype), proven parts, reliable design D Process flow configuration, critical bottlenecks (equipment, spareparts), utilities service interruption B Process flow configuration, critical bottlenecks (equipment, spareparts), utilities service interruption B Flood exposure: river flood, flash flood, storm surge, tsunami D Flood exposure: river flood, flash flood, storm surge, tsunami E Rating criteria Physical condition of machines and equipment, technical age, corrosion A Physical condition of machines and equipment, technical age, corrosion D Interdependency within the company (IBI): units, machines, plants, subsidiaries, associated companies E Interdependency within the company (IBI): units, machines, plants, subsidiaries, associated companies B Wind exposure: extratropical storm, tropical cyclone, tornado, hurricane E Wind exposure: extratropical storm, tropical cyclone, tornado, hurricane E Rating criteria Maintenance programs, inspection and regular diagnostics D Maintenance programs, inspection and regular diagnostics D Contingent business interruption (CBI): customers, suppliers, service providers 0 Contingent business interruption (CBI): customers, suppliers, service providers 0 Extreme weather conditions: hail, lightning, freezing, snow C Extreme weather conditions: hail, lightning, freeze, snow D Rating criteria Technical safety features, emergency shutdown A Technical safety features, emergency shutdown C Business continuity management D Business continuity management A Other perils: volcanism, avalanche, landslide D Other perils: volcanism, avalanche, landslide D Rating criteria Experienced and well qualified staff C Experienced and well qualified staff C 0 0 0 0 Protection level A = Excellent (8099) B = Good (6079) C = Standard (4059) A = Very low (019) B = Low (2029) C = Typical (4059) E = Very high (8099) Hazard potential Protection level Hazard potential 0 = Not applicable D = Moderate (2039) E = Critical (019) 0 = Not applicable 33% 29% Chemicals, petrochemicals, plastics, pharma Hazard potential Protection level Protection level: Operational risk management and corporate risk control programs 25% Hazard potential Protection level Hazard potential Protection level D = High (6079) Company, site name Main occupancy 88% 57% 33% 29% 63% Fire, explosion and operational risk Machinery breakdown and technical risk Business interruption and contingency risk Corporate group Address ABC XYZ 123 Industry category Protection level: Constructional precautions and prevention measures Protection level: Technical protection systems and firefighting means Comment Fire, explosion and operational risk Risk class (14)* Date of assessment 01.01.2015 Protection level: Organizational measures and loss prevention procedures Natural hazard and external perils 75% 15% Protection level: Hazards identification and exposure monitoring Weighted rating* Nein High operational risk 56% 63% 58% 38% 15% 88% Protection level: Safety precautions and prevention measures 63% 75% Hazard potential: Exposure, hazards and risks Machinery breakdown and technical risk Hazard potential: Exposure, hazards and risks Natural hazard and external perils RiskMatrix Plastics prosessing: injection moulding, extrusion, etc. Hazard potential: Exposure, hazards and risks Protection level: Safety precautions and prevention measures Business interruption and contingency risk Protection level: Safety precautions and prevention measures Language / Sprache* Risk engineer English ABC 83% Hazard potential: Exposure, hazards and risks 25% RISK EXPERTS - RiskMatrix, Beispieldaten.xlsm 20.02.2015

Upload: tranmien

Post on 05-Jun-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

2015

Advice: grey fields to be completed manually (others are computed automatically)! V150218

3

* comparison to other occupancies or benchmarking is reasonable only in case of similar risk class!

*multi‐lingual selection and weighted rating only availlable in the full version!

Risk 

assessment 

category

Rating

Rating criteria

Operational risks: 

occupancy hazards, high 

pressure, high temperature, 

chemical reactionsA

Detection:

sensors (fire, gas, ignition 

sources), alarm management 

(manual, automatic)A

Location:

surrounding, neighborhood

A

Fire water supply: 

water source, fire water 

pumps, fire water mains, 

outdoor hydrant systemD

Inspections: 

organization, programs, 

procedures, 

mechanical / electricalD

Risk management:

philosophy, safety 

organization, safety culture, 

risk awareness, management 

KPI's

C

Rating criteria

Warehouse risks: 

block storage, high rack 

storage, tank farms B

Monitoring:

process control, control 

rooms, server rooms, data 

processingB

External layout: 

spacing between buildings 

and units, fire complex 

separationB

Fixed and automatic fire 

suppression systems: 

sprinkler, deluge, foam, CO2 D

Maintenance / repairs: 

organisation, programs, 

procedures, impairment 

handling, preventive / 

protective

E

Hazard analysis:

programs (HAZOP), 

emergency plan, change 

management0

Rating criteria

Material risks: 

fire load, flammable liquids, 

combustible gases, fine dust, 

explosivesD

Security: 

burglary protection, intruder 

alarm B

Internal layout: 

physical separation within 

buildings and units, fire area 

compartmentationE

Manual fire fighting systems: 

hose reel boxes, indoor 

hydrants, fire monitors, 

extinguishersB

Safety installations control:

Inspection and maintenance 

of fire fighting equipment and 

safety featuresC

Documentation:

fire safety plan, emergency 

operating procedures, P&Ids C

Rating criteria

Utilities service risk: 

electricity, steam, 

compressed air, heating, 

cooling, technical gases, IT & 

EDP

B

  

0

Construction: 

materials, insulation, 

fireproofing D

Emergency response:

Public / plant fire brigade, full‐

time (24/7) / voluntary, 

emergency team, response 

time, equipment

C

Workforce: 

staffing, education, 

experience, training, 

contractorsD

Safety audits:

inspection rounds, response 

to recommendations, 

incident investigationB

Rating criteria

Process risk:

size of the plant, complexity 

of processes, capacity, 

utilizationA

  

0

Leakage control: 

Drainage, curbing, 

embankments, spill 

protectionB

Isolation and interlocks:

Automatic shut‐down (ESD), 

unit isolation means, 

automatic interlock devicesB

Safe work practice:

Shift hand‐over , work 

permits, smoking ban, 

housekeeping, storage 

practice

B

Claims handling:

claims handling procedures, 

crisis management team, 

crisis control roomC

Rating criteria

  

0

  

0

Building and equipment 

integrity:

technical age, operating 

hours, design codes, state of 

repair

A

Special protection: 

smoke vents, explosion 

protection, lightning 

protection, oxygen reductionA

Safety at work:

safety management, 

commitment to safety, 

personnel protection 

equipment

C

  

0

Risk 

assessment 

category

Rating

Rating criteria

Plant configuration, 

complexity, 

operation mode C

Plant configuration, 

complexity, 

operation mode E

General: 

Annual turnover, 

replacement time, peak 

periods, market conditionsC

General: 

Annual turnover, 

replacement time, peak 

periods, market conditionsA

Earthquake

D

Earthquake

D

Rating criteria

Proven technology 

(no prototype), 

proven parts,

reliable design B

Proven technology 

(no prototype), 

proven parts,

reliable design D

Process flow configuration, 

critical bottlenecks 

(equipment, spareparts), 

utilities service interruptionB

Process flow configuration, 

critical bottlenecks 

(equipment, spareparts), 

utilities service interruptionB

Flood exposure: 

river flood, flash flood, storm 

surge, tsunami D

Flood exposure: 

river flood, flash flood, storm 

surge, tsunami E

Rating criteria

Physical condition of 

machines and equipment,

technical age,

corrosionA

Physical condition of 

machines and equipment,

technical age,

corrosionD

Interdependency within the 

company (IBI): units, 

machines, plants, 

subsidiaries, associated 

companies

E

Interdependency within the 

company (IBI): units, 

machines, plants, 

subsidiaries, associated 

companies

B

Wind exposure: 

extratropical storm, tropical 

cyclone, tornado, hurricane E

Wind exposure: 

extratropical storm, tropical 

cyclone, tornado, hurricane E

Rating criteria

Maintenance programs,

inspection and regular 

diagnostics D

Maintenance programs,

inspection and regular 

diagnostics D

Contingent business 

interruption (CBI): customers, 

suppliers, service providers 0

Contingent business 

interruption (CBI): customers, 

suppliers, service providers 0

Extreme weather conditions: 

hail, lightning, freezing, snow

C

Extreme weather conditions: 

hail, lightning, freeze, snow

D

Rating criteria

Technical safety features,

emergency shut‐down

A

Technical safety features,

emergency shut‐down

C

Business continuity 

management

D

Business continuity 

management

A

Other perils: 

volcanism, avalanche, 

landslide D

Other perils: 

volcanism, avalanche, 

landslide D

Rating criteria

Experienced and well 

qualified staff

C

Experienced and well 

qualified staff

C

  

0

  

0

  

0

  

0

Protection level

A = Excellent         (80‐99)

B = Good                 (60‐79)

C = Standard           (40‐59)

  A = Very low             (0‐19)

  B = Low                       (20‐29)

  C = Typical                 (40‐59)

  E = Very high             (80‐99)

Hazard potential

Protection level

Hazard potential

  0 = Not applicable

D = Moderate        (20‐39)

E = Critical               (0‐19)

0 = Not applicable

33% 29%

Chemicals, petrochemicals, plastics, pharma

Hazard potential

Protection level

Protection level:

Operational risk management 

and 

corporate risk control programs

25%Hazard potential

Protection level

Hazard potential

Protection level

  D = High                      (60‐79)

Company, site name

Main occupancy

88%

57%

33%

29%

63%

Fire, explosion 

and operational risk

Machinery breakdown 

and technical risk

Business interruption 

and contingency risk

Corporate group

Address

ABC

XYZ

123

Industry category

Protection level:

Constructional precautions and 

prevention measures

Protection level:

Technical protection systems 

and 

fire‐fighting means

Comment

Fire, explosion and operational risk

Risk class (1‐4)*

Date of assessment

01.01.2015

Protection level:

Organizational measures and 

loss prevention procedures

Natural hazard 

and external perils  

75%

15%

Protection level:

Hazards identification and 

exposure monitoring

Weighted rating*

Nein

High operational risk

56%63% 58% 38%

15%88%

 Protection level:

Safety precautions and 

prevention measures

63% 75%

 Hazard potential:

Exposure, hazards and risks

Machinery breakdown and technical risk

 Hazard potential:

Exposure, hazards and risks

Natural hazard and external perils

RiskMatrix

Plastics prosessing: injection moulding, extrusion, etc.

 Hazard potential:

Exposure, hazards and risks

 Protection level:

Safety precautions and 

prevention measures

Business interruption and contingency risk

 Protection level:

Safety precautions and 

prevention measures

Language  /  Sprache*

Risk engineer

English

ABC

83%

 Hazard potential:

Exposure, hazards and risks

25%

RISK EXPERTS - RiskMatrix, Beispieldaten.xlsm 20.02.2015

RiskMatrix

Assessment 

(rating)

AVERY 

LOW

Fire, Business Interruption, Machinery Breakdown, etc.: 

considerably lower than a typical risk 

in the industry peer group

NatCat: according to exposure analysis

EXCELLENT

‐ expectations exceeded

‐ no deficiencies

‐ best of class

‐ no risk improvement recommendations

‐ management strives for perfection

B LOW

Fire, Business Interruption, Machinery Breakdown, etc.: 

lower than a typical risk in the industry peer group

NatCat: according to exposure analysis

GOOD

‐ expectations met

‐ minor deficiencies

‐ exemplifies best practices standards

‐ minor risk improvement recommendations

‐ management strives for proactive compliance

C TYPICAL

Fire, Business Interruption, Machinery Breakdown, etc.: 

comparable to a typical risk in the industry peer group

NatCat: according to exposure analysis

STANDARD

‐ expectations mostly met

‐ no noteworthy deficiencies

‐ best practice standards

‐ room for improvement

‐ compliant, requirements are met

D HIGH

Fire, Business Interruption, Machinery Breakdown, etc.: 

higher than a typical risk in the industry peer group

NatCat: according to exposure analysis

MODERATE

‐ expectations partially met

‐ significant deficiencies

‐ some areas are below best practice standards

‐ considerable potential for improvement

‐ reactive, intent is to do the minimum

EVERY 

HIGH

Fire, Business Interruption, Machinery Breakdown, etc.: 

considerably higher than a typical risk 

in the industry peer group

NatCat: according to exposure analysis

CRITICAL

‐ expectations not met

‐ critical deficiencies

‐ few or none of best practice standards are met

‐ major improvements required

‐ defensive, culture of “cutting corners”  

The evaluation form is divided into four sections, each representing a specific risk:

  Fire, explosion and operational risks

  Machinery breakdown and technical risks

  Business interruption and bottlenecks

  Natural hazard and external perils

Hazard

potential:

Protection

level:

Each box is subject to an individual rating with five rating categories (plus 0 = not applicable):

Hazards potential Protection

A = Very low   A = Excellent      

B = Low   B = Good            

C = Typical    C = Standard

D = High   D = Moderate    

E = Very high   E = Critical

0 = Not applicable                           0 = Not applicable                          

Disclaimer:

The RiskMatrix provides a rough overview of the classification of hazards and risks. The prevailling evaluation is carried out based on the information and assessment rating made by the 

user. The evaluation results are to be understood as a rough estimate and as a principle cannot provide a comprehensive or complete picture of the actual risk situation. It is expressly 

stipulated that no claims can arise therefrom. All liability is excluded.

Input data cells are color‐coded "grey". 

All other cells are for information or for condition based response to the user. 

The rating can be addressed by using the computer mouse (drop‐down menu), 

or by manually typing the respective letter to the corresponding cell.

Hazard potential:

Threat of hazards and perils at the site.

Protection level:

Loss prevention measures for mitigating the impact of hazards and perils.

Each category (risk) is composed of two dimensions (spreadsheet columns) of.

The higher the likelihood and impact of a particular risk (hazard potential) 

the higher are the requirements for safety equipment and protective measures (protection level).

Threat of hazards and perils at the site. 

The evaluation indicates the exposure level compared to typical (similar) examples within an industry segment (occupancy category). 

Loss prevention measures for mitigating the impact of hazards and perils. 

The evaluation indicates the protection level compared to typical (similar) examples within an industry segment (occupancy category). 

3Dr. Michael Buser

RiskMatrix

4Dr. Michael Buser

RiskMatrix