RT Operations RF Power Sources Linac Systems System Operation Ivan Konoplev, JAI Oxford University Peter McIntosh, STFC ASTeC

Upload: others

Post on 24-Mar-2020

6 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

RT Operations

RF Power SourcesLinac Systems

System Operation

Ivan Konoplev, JAI Oxford UniversityPeter McIntosh, STFC ASTeC

Page 2: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Introduction & Goals

• Accelerator technologies:– RF Sources– Linacs– Operational Experiences

• Quality• Reliability• Size/Modularity• Servicing/Maintenance• Costs

• Questions issued (non-exhaustive), collate feedback, try to converge on an optimum RT approach.

• What are technology development opportunities:– efficiency, robustness, simplicity, stability

Page 3: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Session Programme

13:45 – 14:00 Introduction & Goals

14:00 – 15:45 RF Sources & Linacs (I Konoplev, P McIntosh)

Affordable Linacs (U Amaldi)

• Quality

• Reliability

• Size/Modularity

15:45 – 16:15 Coffee

16:15 – 17:45 Operational Experience (J Van Dyk)

• Service/Maintenance

• Operability

• Costs

Page 4: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Klystron – based on inertial bunching mechanism of RF generation

• Efficiency - up to 85% (research) and 60% (commercial) –running cost savings

• Commercial availability in broad frequency range operating range from 0.1GHz up to 15GHz

• Versatile, reliable they are operating at 100s (A) beam current and 10s (kV)

• Can be high average power up to 1MW

• However they are more expensive Basic schematic of two cavity klystron

Technical drawings of a multi-cavity cavity klystron

Page 5: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Example of typical operation data

Page 6: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Example of absolute rating

Page 7: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

What to expect from vendors

• The tube price is about £100k and can be negotiated with up to 15% reduction if one buys 10 of them.

• Spec. for life time is 5000 hours (sure can run > 10 000 but not specified as such in official offers).

• Tube can be repaired (new cathode) for 30% of initial price. • New tube as compared to existing tubes with similar peak power should save

>30% of modulator cost (low voltage, no oil tank) and it is very compact (1/3 of standard modulator in volume).

Page 8: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Magnetron – M-type tube generates RF if electrons are losing “potential” energy

• It is an Oscillator and cannot be used as an amplifier

• Not expensive (1/3rd of klystron price) but not as reliable, life time is an issue for HP devices

• Power up to 3MW (peak power) good for low energy LINCAS (up to 6MeV)

• Operating frequency range 0.1GHz to high 10s GHz

• Versatile but not stable and operating frequency

may walk around

The cathode in a magnetron is harder to cool than

in a klystron and gets additional heating from back

bombardment so the maximum output is far less

than a klystron

Page 9: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Magnetron

Schematic view of the magnetron and its operation

Cathode is heated to generate the electrons but it is also heated by the electrons coming back –erosion of the cathode

Magnetrons are cheap to manufacture but it cannot be controlled to the level of the klystron

Page 10: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Example of magnetron controls

Page 11: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Magnetron and Klystron

Cost

Page 12: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Solid state RF power supply

• Efficiency - comparable with klystron but less

• Water cooling is required

• Modular

• High power (1MW level) will be available at 750MHz soon

• At frequencies above 1 GHz the high power will be available in the next 3-5 years

• Expensive but relatively easy to run

Typical table from one of the vendors

Klystron SSA-1 SSA-NIOT

Page 13: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Example of SSA RF power supplies

One of the most complicated parts are power combiner and cooling

Page 14: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Vacuum Tubes vs SSA

Page 15: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Just to make it more complex the following subsystems are needed

Regardless of the power supply chosen to drive the accelerator

Page 16: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Klystron vs Magnetron vs SSA Klystron Magnetron SSA

Efficiency 50%-70% Up to 90% 50%-70%

Frequency (GHz) 0.1 – 15 0.1 – 15 up to 1

Peak Power (MW) Up to 10 Up to 3 <1

Stability high low high

Life expectancy high low high

Cooling yes yes yes

Maintenance complex complex simple

Size compact compact large

Mobility yes yes yes

Modularity partial partial yes

Capital Cost high intermediate high

Run Cost intermediate intermediate intermediate

SSA is a good solution for the future but klystron is the answer to have reasonable cost/quality ratio

Page 17: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Accelerator technology standing wave and traveling wave

LINACs

Standing wave LINAC

Traveling wave LINAC

VariabilitiesFrequency, gradient, phase velocity, geometry, shunt impedance, Q Factor

Page 18: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Standing wave LINAC

More compact c.f. TW structures (particularly when optimally coupled)Typically utilised for heavy ion, proton or short pulse electron linacs

Page 19: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Traveling wave LINAC

Electron bunch propagates with the wave in accelerating phase

Short fill time structures c.f SW structuresNormally utilised for short beam pulse machines, linear colliders or SR injectors

Page 20: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

TW vs SWIncr. loss Incr. Trans-time

SW Side-Coupled optimised to reach >100M/m with small beam-pipe (6mm)Resonant coupling – maximise group velocity

Comparison of Standing-Wave and Travelling-Wave Structures, R Miller (SLAC), Linac86

SW

TW

Dominated by RF source costs

Page 21: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

S-Band SW Structures (SAMEER)

Compton X-Ray Source

Parameter Value

Frequency (MHz) 2998

# Cells 24

Coupling Mode Side /2

Effective Shunt Impedance (M/m) 87

Q Factor 15000

Length (m) 1.12

RF Input Power (MW) 5.5

Energy (MeV) 15

Page 22: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

S-Band TW Structures (TTX)

Parameters Units

Length 1.5m

Mode 3/4π

Cell length 39.3mm

Number of cells 38(with coupler)

f ~2856MHz

a 10.6mm-8.1mm

vg/c 0.83%~0.3%

Rs 64.6MΩ/m~71.8MΩ/m

Filling Time 960ns

Eacc(Pin=30MW) 30MV/m

Page 23: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

C-Band SW Structures (Tsinghua U/Nuctech)

Parameter Value

Frequency (MHz) 5712

# Cells 12

Coupling Mode On-axis

Effective Shunt Impedance (M/m) 130

Q Factor 10500

Length (m) 0.29

Eacc (MV/m) 21

RF Input Power (MW) 2.16

Energy (MeV) 6

Page 24: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

C-Band TW Structures (SwissFEL)• Structures are machined “on tune”, no

provisions for dimple tuning!

• Cup manufacturing with micron precision at VDL ETG Switzerland

• Coupler manufacturing at VDL ETG

• Stacked by robot at PSI

• Vacuum-brazed at PSI

• Production rate: 1-2 / week

• Production finished August 2016

• High power results for first structure: Conditioned to 52 MV/m Break-down rate at 52 MV/m

≈ 2 x 10-6

At nominal 28MV/m, break-down rate negligible (well below the specified threshold of 10-8)

R. Zennaro et al., “Measurement and High Power Test of the First C-Band Accelerating Structure for SwissFEL”, Proceedings of LINAC2014, Geneva, Switzerland

Page 25: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

X-Band SW Structures (SLAC & BIEVT)

• Performance of two of them was limited to gradients lower than 55 MV/m by breakdowns in the couplers.

• Breakdowns may be related to the high RF magnetic and moderate RF electric fields on the sharp edges at the waveguide-to-coupler cell opening.

SLAC BIEVT

Page 26: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

X-Band TW Structures (CLIC)

25 cmMicron–precision disk

• 11.994 GHz, X-band• 100 MV/m accelerating gradient• Input power ≈50 MW• Pulse length ≈200 ns• Repetition rate 50-400 Hz

Page 27: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Linac Comparison

S-Band C-Band X-Band

SW(SAMEER)

TW(TTX)

SW(TU/Nuctech)

TW(SwissFEL)

SW (SLAC)

SW(BIEVT)

TW (CLIC)

Frequency (MHz) 2998 2856 5712 5712 11400 9300 11994

Operating Mode Side /2 3/4 On-axis /2 2/3 On-Axis

On-Axis/2

2/3

Eff. Shunt Impedance (M/m) 87 71.8 130 80 81.9 133 112

# Cells 24 38 12 113 15 11 24

Q Factor 15000 16566 10500 10000 8600 7100 6265

Length (m) 1.12 1.5 0.29 2 0.2 0.15 0.23

RF Input Power (MW) 5.5 31 2.16 28 6 1 63.8

Eacc (MV/m) 17 30 21 28 50 14 100

Energy (MeV) 15 45 6 56 10 2 23

Page 28: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Acknowledgements

RF Sources LinacsI Syratchev (CERN) W Wuensch (CERN)G Burt (Lanc U) G Burt (Lanc U)A Dexter (Lanc U)A Wheelhouse (STFC)

Affordable Linacs, U Amaldi (TERA Foundation)

RF Questions

Page 29: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Accelerator Technologies

RF Sources• Linacs can potentially be driven by Magnetron, Klystron or Solid state

devices - do you have any preferences? Why?• Which accelerator technology is most commonly used?

Linacs• Which accelerator technology is most commonly used • Pro’s/Con’s of the accelerators used for the treatments, what is the most

annoying part of working with the accelerator• List the electron beam energies needed for a cancer treatment• List electron beam current needed for a cancer treatment• Can current generation of LINAC available in hospitals deliver the required

parameters• Linacs based on Travel Wave/Standing waves do you have any

preferences? Why?

Page 30: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Quality

• Electron beam quality i.e. beam dimensions and dispersion?

• Accuracy of beam delivery to the target?

• Electron beam stability over the treatment time?

• Which accelerator technical parameters are the most important for a cancer treatment?

Page 31: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Reliability

• Accelerator stability i.e. how stable it should be and what are the acceptable boundaries of parameters variations?

• Change of the environment and reliability: how stable environment conditions can be provided i.e. cost of running environment stable conditions against the cost of environment robust accelerator?

Page 32: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Size

• Favourable preferable dimensions for the accelerator?

• What is more preferable compact but more expensive accelerator or capital cost to upgrade the hospital available rooms to accommodate the facility?

Page 33: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Second Session – 16:15 – 17:45

16:15 RT Technology Operation Experience, J Van Dyk (Western Univ, London, Canada)

Servicing/Maintenance

Operability

Costs

Page 34: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Services/Maintenance

• Availability of technical personal?

• Availability of mechanical and electrical workshops to fix things locally?

• Stable water and electricity supplies?

• What are servicing requirements, capability available, how modular does system need to be?

Page 35: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Operability

• What is important efficiency criteria – initial costs or operating costs, (is it important to reduce energy consumption by 10% or it would be important to reduce the initial cost of the equipment by 10%)?

• What cooling configurations are deemed appropriate (additional water cooling or well-conditioned room)?

• What level of controls needed – cost implications? Manual but cost reduced system or fully automated but more expensive?

• What are stability requirements – which components need tight control?

Page 36: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Costs

• Capital vs Operating?

• Technology drivers?

• Manufacturing techniques?

Page 37: RF Power system for LINAC · • However they are more expensive Basic schematic of two cavity klystron Technical drawings of a multi-cavity cavity klystron . ... • It is an Oscillator

Combined Session Summary

• Capture of key points raised– Energy– Frequency– Size– Source technology– Staffing – expertise and training needed– Operability constraints – local infrastruture

• Opportunities for development of RT concepts:– Scope?– Market research?– Technology R&D?