relay v23003

Upload: aussamayounis8848

Post on 29-May-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/9/2019 Relay v23003

    1/10

    Cradle Relay P

    The Best Relaytion

    108-98015

    Rev. BEC-JM00-0009-03

    ECOC: JM10

    1. Aug. 04

  • 8/9/2019 Relay v23003

    2/10

    Features

    Primarily intended for impulse operation

    highly reliable

    Multi purpose relay

    great variety of contact arrangements and materials to

    meet specific applications

    Sockets for easy and quick mounting of relays (see data

    sheet Accessories)

    Contacts for signal loads and currents up to 5 A

    Typical applications

    For applications where the switching status must

    be maintained

    Measuring systems

    Cradle Relay P V23003

    Hand solder and plug-in relays,

    for DC operation,

    polarized, non-latching

    Versions

    Size I or II, depending on contact set

    Standard contact sets with max. 4 changeover, 2 break or

    2 make contacts, special configurations on request

    Single or bifurcated contacts

    Hand solder terminals also for plug-in connection with

    screw fixing

    Dust-protected

    Page 2 (10) 108-98015 Rev. B

    European Directive conformance:

    Cradle P relay product conformance according to:

    - Directive 2000/53/EC: ELV (End of Life of Vehicles)

    - Directive 2002/95/EC: ROHS (Restrictions of the

    use of certain hazardous substances in electrical and

    electronic equipment)

    Compliance is evidenced by written declaration from all raw

    material suppliers.

    Tyco Electronics AXICOM only has responsibility for the properprocessing of these materials.

    Confirmation is valid for date codes 0501

  • 8/9/2019 Relay v23003

    3/10

    Dimension drawing (in mm)

    Cradle Relay P V23003

    Version V23003-A0xxx Size I and

    V23003-B0xxx Size II

    Hand solder terminals, silver-plated

    Also for plug-in connection

    and screw fixing

    With earth terminal

    Dust-protected

    Size I Size II

    Page 3 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    4/10

    single contacts

    F 104

    single

    contacts

    B104

    B604

    bifurcated

    contacts

    C104

    C404

    F105 F107 F106

    1 break

    1 make contact

    Cradle Relay P V23003

    Ordering code block 3

    Type of contact

    Contact assembly

    Contact material

    Max. switching voltage

    Max. switching current

    Max. switching capacity

    Max. continuous current at

    max. ambient temperature2 A

    silver,

    gold-flashed

    150 Vdc

    125 Vac

    2 A

    35 to 70 W

    see load limit

    curve page 7

    50 VA

    gold F

    36 Vdc

    30 Vac

    0.2 A

    5 W

    5 VA

    silver,

    gold-flashed

    150 Vdc

    125 Vac

    2 A

    35 to 70 W

    see load limit

    curve page 7

    50 VA

    gold F

    36 Vdc

    30 Vac

    0.2 A

    5 W

    5 VA

    silver,

    gold-flashed

    250 Vdc

    250 Vac

    5 A

    50 to 140 W

    see load limit

    curve page 7

    500 VA

    5 A

    Contact DataB104/B110/ B604/B610/ C104/C110 C404/C410 F104 ... F107

    max. 4 changeover contacts, 2 break contacts or 2 make contacts

    single contacts bifurcated contacts single contacts

    single contacts

    B110

    B610

    bifurcated contacts

    C110

    C410

    Number of contacts and type

    Symbols with base conncections

    Contacts in release condition,

    coil polarity to set the relay

    Contact assembly

    Contact material silver, gold-flashed

    Ordering code block 3

    Contact material gold F

    Ordering code block 3

    4 changeover contacts 2 changeover contatcs

    Size II

    Contact sets

    Number of contacts and type

    Symbols with base conncections

    Contacts in release condition,

    coil polarity to set the relay

    Contact assembly

    Contact material silver, gold-flashed

    Ordering code block 3

    Contact material gold F

    Ordering code block 3

    2 changeover contacts 2 make

    contacts

    single contacts

    Size I

    2 break

    contacts

    3 2 4 1

    - I + - II +

    3 2 4 1

    - I + - II +

    Page 4 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    5/10

    Coil number

    Ordering

    code block 2

    026

    025

    037

    064

    044

    24.5 2.5

    24.5 2.5

    100 10

    100 10

    400 60

    340 34

    1400 210

    1400 210

    2400 360

    2400 360

    3 2

    4 1

    3 2

    4 1

    3 2

    4 1

    3 2

    4 1

    3 2

    4 1

    6

    12

    24

    48

    60

    from 6 Vdc to 60 Vdc

    1.5 W

    1

    max. 73% of the nominal voltage

    Cradle Relay P V23003

    Operating voltage range at 20 C

    Minimum voltage UI

    Maximum voltage UII

    Vdc Vdc

    Nominal

    voltage

    Unom

    Vdc

    Terminals

    Start End

    Resistance

    at 20 C

    Coil Data

    UI tamb

    = UI

    20 C k

    I tamb

    UII tamb

    = UIl 20 C kII tamb

    tamb

    = Ambient temperature

    UI tamb

    = Minimum voltage at ambient temperature, tamb

    UII tamb

    = Maximum voltage at ambient temperature, tamb

    kI

    and kII

    = Factors

    Coil version

    Nominal voltage

    Typical nominal power consumption, at 20C

    Class of the operative range

    acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201

    Operating voltage (according to the coil type)

    Win-

    ding

    With continuous operation only one winding at a time may be energized

    within the specific voltage range.

    The minimum voltage UI

    and the maximum voltage UII

    depends on the

    ambient temperature.

    4.0

    4.0

    8.0

    8.0

    16.5

    16.5

    33.5

    33.5

    44

    44

    6.7

    6.7

    13.5

    13.5

    26.5

    25

    49

    49

    65

    65

    I

    II

    I

    II

    I

    II

    I

    II

    I

    II

    Operate - negative potential at start of winding Release - plus potential at start of winding

    Page 5 (10) 108-98015 Rev. B

    Ambient temperature [C] Ambient temperature [C]

  • 8/9/2019 Relay v23003

    6/10

    Cradle Relay P V23003

    Instructions for impulse operation

    Cradle relay P is primarily intended for impulse operation. The maximum voltage stated in the table (page 5) can

    be increased for impulse operation as follows:

    UII Impuls

    = UII tamb

    . q

    UII tamb

    = Maximum continuous voltage at ambient temperature tamb

    q = Factor

    The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or 3.3 times

    at ambient temperature = 20 C and 2.3 times at ambient temperature < 20 C the value of the maximum volta-

    ge listed in the table (page 5).

    Examples of various periodic pulse trains (energizing side)

    IftED

    = Pulse width

    t2

    = Cycle time

    If tED

    = > 3 s the value of q must be obtained from the nomograph (cradle relay N datasheet page 10).

    1. Periodic recurrence of one energizing pulse

    IftED

    3 s then q =

    tED

    = tI+ t

    II

    tI

    = Pulse width of the positive pulse at the start of the winding

    tII

    = Pulse width of the negative pulse at the start of the winding

    tI + t

    II= Pulse widths within one cycle

    2. Periodic recurrence of two unequal energizing pulses

    Page 6 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    7/10

    4 ms

    4 ms

    20 operations/s

    -40 C ... +70 C

    50 K/W

    100 C

    1.6 W

    dust-protected IP 30

    approx. 107 operations

    any

    approx. 25 g

    approx. 30 g

    Cradle Relay P V23003

    Load limit curve

    Safe breaking, no stationary arc

    Contact material silver, gold-flashed

    500 Vacrms

    500 Vacrms

    500 Vacrms

    500 Vacrms

    1000 Vacrms

    1000 Vacrms

    B1xx B6xx C1xx C4xx F1xxOrdering code block 3

    Test voltage (1 min)

    winding / frame

    contact / contact

    contact / frame

    Operating time at Unom

    and 20 C, typical

    Release time, typical

    Maximum switching rate without load

    Ambient temperature range

    acc. to EN 61810-1 / IEC 61810-1 and

    VDE 0435 part 201

    Thermal resistance

    Maximum temperature

    Continious thermal load

    Degree of protection acc. to EN 60529 /

    IEC 60529 / VDE 0470 part 1

    Mechanical endurance

    Mounting position

    Weight

    Size I

    Size II

    General data

    Insulation

    Contact sets F1xxContact sets B1xx and C1 xx

    Page 7 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    8/10

    Cradle Relay P V23003

    Basic type number of cradle relay P

    Relay type

    A0 = Size I

    B0 = Size II

    Coil numberVersions see page 5

    Contact set / type of contact

    see page 4

    Ordering example:V23003-B0037-F104

    Cradle relay P, size II, dust-protected, coil 24 Vdc, 2 changeover contact set, single contacts, con-

    tact material silver, gold-flashed

    Note:

    The ordering scheme enables a multitude of variations. However, not all variations are defined as construc-

    tion specifications (ordering code) and thus in the current delivery program.

    Special design can be carried out to customer specifications. Please contact your local representative.

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Digit

    Block 1 Block 2 Block 3

    V 2 3 0 0 3

    V23003A 44B104 1-1393817-8

    V23003B 37B110 3-1393817-9

    V23003B 37C110 4-1393817-1

    V23003B 37F104 4-1393817-5V23003B 64B110 6-1393817-3

    Relay Code Tyco

    Part Number

    Ordering Information

    Page 8 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    9/10

    IM Relays4th generation slim line low profile polarized 2 c/o telecom relay with

    bifurcated contacts, available as non latching or latching relay with

    1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption

    of 140... 200 mW, latching relays with 1 coil 100 mW. The IM relay

    is available as through hole and surface mount type (J-Legs and Gull

    Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric

    strength fulfills the Bellcore requirements according GR 1089 (2,5 kV

    2 / 10 s) and FCC part 68 (1,5 kV 10 / 160 s). The IM relay is

    CECC/IECQ approved and certified in accordance with IEC/EN 60950

    and UL1950. Dimensions approx. 10 x 6 mm board space and

    5.65 mm height.

    P2 Relays3rd generation polarized 2 c/o telecom relay with bifurcated contacts,

    available as non latching or latching relay with 1 or 2 coils. Nominal

    voltage range from 3 ... 24 V, coil power consumption 140 mW,

    latching relays with 1 coil 70 mW. The P2 Relay is available as through

    hole or surface mount type and capable to switch currents up to 5

    A. Dielectric strength fulfills the Bellcore requirements according GR

    1089 (2,5 kV 2 / 10 s) and FCC part 68 (1,5 kV 10 / 160 s).Dimensions approx. 15 x 7,5 mm board space and 10 mm height.

    FX Relays3rd generation polarized 2 c/o telecom relay with bifurcated contacts,

    available as non latching or latching relay with 1 coil. Nominal voltage

    range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the

    high sensitive version, 140... 300 mW for the standard version, latching

    relays with 1 coil 100 mW. The FX2 relay is available as through hole

    type and capable to switch loads up to 60 W/62,5 VA. Dielectric

    strength fulfills the Bellcore requirements according GR 1089 (2,5 kV

    2 / 10 s) and FCC part 68 (1,5 kV 10 / 160 s). The FX2 is CECC/

    IECQ approved and certified in accordance with IEC/EN 60950 and

    UL1950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm

    height.

    FT2 / FU2 Relays3rd generation non polarized, non latching 2 c/o telecom relay with

    bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power

    consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as

    through hole and surface mount type. Dielectric strength fulfills the

    Bellcore requirements according GR 1089 (2,5 kV 2 / 10 s) and FCC

    part 68 (1,5 kV 10 / 160 s). The FT2/FU2 is CECC/IECQ approved

    and certified in accordance with IEC/EN 60950 and UL1950.

    Dimensions approx. 15 x 7,5 mm board space and 10 mm height.

    FP2 Relays3rd generation polarized 2 c/o telecom relay with bifurcated contacts,

    available as non latching or latching relay with 1 or 2 coils. Nominalvoltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW

    for the high sensitive version, 140... 300 mW for the standard version,

    latching relays with 1 coil 100 mW.. The FP2 Relay is available as

    through hole type and capable to switch loads up to

    30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV 10 /

    160 s). The FP2 is CECC/IECQ approved. Dimensions approx.

    14 x 9 mm board space and 5 mm height.

    MT2 / MT42nd generation non polarized, non latching 2 c/o and 4 c/o telecom and

    signal relay with bifurcated contacts. Nominal voltage range from 4.5 ...

    48 V, coil power consumption 150/200/300/400 and

    550 mW, and 300 mW (MT4). Dielectric strength fulfills the

    requirements according FCC part 68 (1,5 kV 10 / 160 s) for both

    and the Bellcore requirements according GR 1089 (2,5 kV 2 / 10 s)

    the MT4 only.

    Dimensions MT2 approx. 20 x 10 mm board space and 11 mm height,

    MT4 approx. 20 x15 mm board space and 11 mm height.

    D2n Relays2nd generation non polarized 2 c/o relay for telecom and various

    other applications. Nominal voltage range from 3 ... 48 V, coil power

    consumption from 150 .... 500 mW. The D2n relay is capable to

    switch currents up to 3 A. Dielectric strength fulfills the requirements

    according FCC part 68 (1,5 kV 10 / 160 s). Dimensions approx.

    20 x10 mm board space and 11,5 mm height.

    P1 RelaysExtremely sensitive, polarized 1 c/o relay with bifurcated contacts for

    a wide range of applications, available as non latching or latching relay

    with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power

    consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay

    is available as through hole or surface mount type and capable to

    switch currents up to 1 A. Dielectric strength fulfills the requirements

    according FCC part 68 (1,5 kV 10 / 160 s). Dimensions approx.

    13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for

    SMT version.

    W11 RelaysLow cost, non polarized 1 c/o relay for various applications. Nominalvoltage range from 3 ... 24 V, coil power consumption 450 mW,

    sensitive versions 200 mW. The W11 relay is capable to switch

    currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx.

    15,6 x 10,6 mm board space and 11,5 mm height.

    Reed RelaysHigh sensitive, non polarized relay for telecom and various other

    applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal

    voltage range from 5 ... 24 V, coil power consumption 50...280 mW

    for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays

    are available in DIP or SIL housing and capable to switch currents up to

    0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric

    strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and

    5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm

    height for SIL version.

    Cradle RelaysExtremely reliable and mature relay family of 1st generation for various

    signal switching applications. Available as non polarized, polarized

    / latching and relay with AC coil. The benefit is the possibility of

    combining various contact sets from 1 up to 6 poles, single and

    bifurcated contacts, different contact materials with a coil voltage

    range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust

    protected and hermetically sealed versions, with plug in or solder

    terminals and are capable to switch currents up to 5 A. Forcibly

    guided (linked) contact sets optional. Dielectric strength 500 Vrms.

    Dimensions from approx. 19 x 24 to 19x35 mm board space and

    30 mm height.

    Other RelaysWe offer a variety of different relay families for maintenance and

    replacement purposes. These relays are up to 60 years old now, such

    as Card Relay SN (V23030 / V23031 series), Small General Purpose

    Relay (V23006 series), Small Polarized Relay (V23063 ... V23067

    and V23163 ... V23167 series). Accessories like sockets, hold down

    springs, etc. optional.

    HF3 RelayHigh performance low cost RF relay with excellent RF characteristics.

    Available with an impedance of 50 and 75 Ohm. Suitable for frequen-

    cies up to 3 GHz. Actually smallest RF relay available combining small

    size, excellent RF performance and SMD solderability. Available as non

    latching or latching relay with 1 or 2 coils and a nominal coil voltage

    range from 3 ... 24 V, coil power consumption 140 mW, latching relays

    with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.

    Cradle Relay P V23003

    Page 8 (10) 108-98015 Rev. B

  • 8/9/2019 Relay v23003

    10/10

    Tyco Electronics AXICOM Ltd.

    Seestrasse 295 - P.O. Box 220

    CH-8804 Au-Wdenswil / Switzerland

    Phone +41 1 782 9111Fax +41 1 782 9080

    E-mail: [email protected]

    Tyco Electronics CorporationPOB 3608,Harrisburg, PA 17105, USAPhone +001 800-522-6752

    Tyco Electronics EC Trutnov s.r.o.

    Komenskho 821

    CZ-541 01 Trutnov / Czech Republic

    E-mail: [email protected]

    Tyco Electronics

    Paulsternstrasse 26

    D-13629 Berlin / Germany

    Phone +49 30 386 38573

    Fax +49 30 386 38575

    E-mail: [email protected]

    Page 8 (10) 108-98015 Rev. B