TECHNICAL REPORT Ultrasonic testing reinspection in the crack located in the upper case of turbine 1 Rev: 00 March 2015 Page 1 of 17 WDS INGENIERIA, S.A. Inspected by: Report by: Eng. Cuicas Wisthon Eng. Cuicas Wisthon Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panamá +507 6662 4768 / +507 68604245 [email protected] ULTRASONIC TESTING REINSPECTION IN THE UPPER CASE BELONGING TO THE TURBINE 1 March 2015

Upload: wisthon-griman

Post on 27-Sep-2015

11 views

Category:

Documents


2 download

DESCRIPTION

modelo de informe de ultrasonido segun practica recomendada asnt

TRANSCRIPT

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 1 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    ULTRASONIC TESTING REINSPECTION

    IN THE UPPER CASE BELONGING TO

    THE TURBINE 1

    March 2015

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 2 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    Panama, March 2015

    Gentlemen:

    CELSIA

    Attention. Eng. Dominguez Milagros.

    REF: Ultrasonic testing reinspection to upper case belonging to

    the turbine Cot C1503-023S

    Respected Engineer

    Attached Technical Report Ultrasonic inspection, by WDS Ingeniera, S.A.,

    Testing conducted in upper case belonging to turbine of CELSIA.

    This report contains observations and conclusions relating to the service.

    Best regard

    ENG. Daniel Rivero ASNT-TC-1A Level II PT, VT, MT.

    Level I UT, ECT AWS Member No 675950

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 3 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    REPORT CONTENTS

    1. OBJECTIVE

    2. INSPECTION DATE, PERSONNEL AND EQUIPMENTS

    3. PROCEDURE OF THE INSPECTION

    4. INPECTION RESULTS AND ANALYSIS

    5. ANNEXES

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 4 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    1. OBJECTIVE

    Evaluate by ultrasonic testing (UT) in the crack located in the upper case

    of turbine 1

    2. DATE OF INSPECTION, PERSONNEL AND EQUIPMENT

    Inspection of the unions was held on February 25th 2015 in Colon, Panama

    The staff was involved for inspection:

    - Eng Cuicas Wisthon, ASNT-TC-1A Level II: VT, PT, MT, and UT.

    EQUIPMENT USED:

    - Ultrasound Equipment Olympus EPOCH LTX.

    - Calibration block IIW Type 1.

    - Digital Camera.

    - Coupling Gel.

    - Tape Measure.

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 5 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    3. PROCEDURE OF INSPECTION

    To determine the length of the crack first of all was gotten the vertical

    distance to the crack from the bottom of the case, this value was called

    X, To get the value of D was assumed Y= 80mm, and the following

    equation was obtained:

    =

    = 80

    = 80

    The actual thickness of the case was determined randomly at certain

    points on the right, left, up and down of the nearest area to the crack to

    determine the error of the assumed value of Y=80 mm, those values

    obtained were the following:

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 6 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    LY1 = 77,40mm

    RY2 = 79,63mm

    UY1 = 76,45mm

    UY2 = 79,74mm

    UY3 = 79,34mm

    UY4 = 78,85mm

    DY1 = 78,75mm

    DY2 = 78,25mm

    DY3 = 78,13mm

    DY4 = 76,43mm

    = LY1 + RY2 + UY1 + UY2 + UY3 + UY4 + DY1 + DY2 + DY3 + DY4

    10

    = 78,35

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 7 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    4. INSPECTION RESULTS, ANALYSIS AND RECOMMENDATIONS

    During the ultrasound inspection of the crack belonging to the upper

    case of the turbine 1, for the detection of the crack on the points UP-12,

    UP-13, UP-14, UP-15, UP-16, UP-17, LEFT-1, LEFT-2, LEFT-3, DOWN-14,

    DOWN-15, DOWN-16, the gain was needed to be increased in 25Db to

    manage to see the crack, otherwise it could have not been detected

    anything, which could means that the crack is extremely thin at these

    points, but due to the high gain it is difficult to know for sure.

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 8 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    REINSPECTION REPORT ULTRASONIC FLAW DETECTOR

    EQUIPMENT USED

    Brand: Olympus Serial: SD010312 Model: EPOCH LTC

    Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz

    Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:

    TECHNICAL PARAMETERS AND INSPECTION

    Technique: Defectology Range: 150 mm Reference level: 65 dB

    DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):

    Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose

    Delay Probe delay Velocity PCS DSS

    0,0 s 6,0 s 3280 m/s N/A N/A

    Defects determination %DAC Defect type

    Result

    Weld Stamping Sector Ubicac. Length Depth (D) X 45 60 70 Acept Reject

    UP 1 33,00 47,00

    UP 2 33,28 46,72

    UP 3 37,00 43,00

    UP 4 31,31 48,69

    UP 5 28,80 51,20

    UP 6 39,25 40,75

    UP 7 35,26 44,74

    UP 8 32,10 47,90

    UP 9 33,66 46,34

    UP 10 29,85 50,15

    UP 11 37,24 42,76

    UP 12 45,57 34,43

    UP 13 46,15 33,85

    UP 14 51,62 28,38

    UP 15 51,85 28,15

    UP 16 52,26 27,74

    UP 17 51,25 28,75

    MADE BY REVIEWED BY APPROVED BY

    COMPANY

    SIGNATURE

    NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas

    DATE 03-06-2015 03-06-2015 03-06-2015

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 9 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    REINSPECTION REPORT ULTRASONIC FLAW DETECTOR

    EQUIPMENT USED

    Brand: Olympus Serial: SD010312 Model: EPOCH LTC

    Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz

    Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:

    TECHNICAL PARAMETERS AND INSPECTION

    Technique: Defectology Range: 150 mm Reference level: 65 dB

    DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):

    Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose

    Delay Probe delay Velocity PCS DSS

    0,0 s 6,0 s 3280 m/s N/A N/A

    Defects determination %DAC Defect type

    Result

    Weld Stamping Sector Ubicac. Length Depth (D) X 45 60 70 Acept Reject

    UP 18 ----- -----

    UP 19 ----- -----

    UP 20 ----- -----

    DOWN 1 43,06 36,94

    DOWN 2 45,87 34,13

    DOWN 3 39,00 41,00

    DOWN 4 27,70 52,30

    DOWN 5 27,00 53,00

    DOWN 6 25,77 54,23

    DOWN 7 33,93 46,07

    DOWN 8 35,73 44,27

    DOWN 9 34,64 45,36

    DOWN 10 38,50 41,50

    DOWN 11 39,87 40,13

    DOWN 12 36,75 43,25

    DOWN 13 39,75 40,25

    DOWN 14 ----- -----

    MADE BY REVIEWED BY APPROVED BY

    COMPANY

    SIGNATURE

    NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas

    DATE 03-06-2015 03-06-2015 03-06-2015

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 10 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    REINSPECTION REPORT ULTRASONIC FLAW DETECTOR

    EQUIPMENT USED

    Brand: Olympus Serial: SD010312 Model: EPOCH LTC

    Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz

    Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:

    TECHNICAL PARAMETERS AND INSPECTION

    Technique: Defectology Range: 150 mm Reference level: 65 dB

    DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):

    Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose

    Delay Probe delay Velocity PCS DSS

    0,0 s 6,0 s 3280 m/s N/A N/A

    Defects determination %DAC Defect type

    Result

    Weld Stamping Sector Ubicac. Length Depth (D) X 45 60 70 Acept Reject

    DOWN 15 ----- -----

    DOWN 16 ----- -----

    DOWN 17 ----- -----

    DOWN 18 ----- -----

    DOWN 19 ----- -----

    DOWN 20 ----- -----

    LEFT 1 41,57 38,43

    LEFT 2 42,67 37,33

    LEFT 3 47,46 32,54

    LEFT 4 ----- -----

    RIGHT 1 44,00 36,00

    RIGHT 2 42,60 37,40

    RIGHT 3 44,20 35,80

    RIGHT 4 46,57 33,43

    MADE BY REVIEWED BY APPROVED BY

    COMPANY

    SIGNATURE

    NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas

    DATE 03-06-2015 03-06-2015 03-06-2015

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 11 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    4. ANNEXES

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 12 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 13 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    PHOTOGRAPHIC RECORD

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 14 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 15 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 16 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]

    CALIBRATION CERTIFICATE

  • TECHNICAL REPORT

    Ultrasonic testing reinspection

    in the crack located in the

    upper case of turbine 1 Rev: 00 March 2015 Page 17 of 17

    WDS INGENIERIA, S.A. Inspected by: Report by:

    Eng. Cuicas Wisthon Eng. Cuicas Wisthon

    Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]