railways 2012 31/07/12 14:37 page1 railways … · railway division 7 t guide for intervention...
TRANSCRIPT
Railways applications
Bahnanwendungen
Electrical safety equipment
Ausrüstung für elektrische Sicherheit
SICAME GROUP Railway division
railways 2012 31/07/12 14:37 Page1
CATU, The world of electrical safety
CATU is the European Leader in Electrical Safety Equipment for Electricity Networks and Installations ; with more than 60 years of experience in this field,we export today more than 45 % of our production to over 120 countries.
CATU is a subsidiary of SICAME GROUP.
Our constant efforts to be the specialist in this field of engineering, naturally broughtus a few years ago to create a Railway Products Division : CEGERS.
Our product range involves the following applications :- Intervention on Catenaries- Intervention on Tramways, Trolleys and Subways- Intervention on Lines, Substations and Installations
This guide shows our range of products for all applications :• Voltage Detectors and Phasing Testers• Short-Circuiting & Earthing Systems• Insulating Sticks• Personal Protective Equipment• Padlocks & Warning Signs• and General Tools
Our catalogue is available on our website www.catuelec.com.
CATU, die Sicherheitsorientierte Welt derElektrizität
CATU ist der europäische Marktführer von Ausrüstung für elektrische Sicherheit imStromnetze und Elektroanlagen. Wir haben mehr als 60 Jahre Erfahrung in diesemBereich und exportieren heutzutage mehr als 45% unseres Jahresumsatzes inüber 120 Ländern.
CATU ist eine Filiale der SICAME GROUP.
Unsere stetige Bemühungen, der Spezialist auf diesem Gebiet der Technik zu sein,hat natürlich uns vor ein paar Jahren, eine „Bahn Products Division“ zu erstellen:CEGERS.
Unser Sortiment umfasst die folgenden Anwendungen:- Einsatz an Oberleitungen - Einsatz an Straßenbahn, S- und U-Bahn - Einsatz an Freileitungen, Umspannwerke und Elektroanlagen
Dieser Leitfaden zeigt unser Produktsortiment für alle Anwendungen:• Spannungsprüfer und Phasenvergleicher • Erdungs- und Kurzschließvorrichtungen• Isolierstangen • persönliche Schutzausrüstung • Vorhängeschlösser & Warnzeichen • allgemeine Werkzeuge
Bitte finden Sie den Katalog auf www.catuelec.com.
railways 2012 31/07/12 14:37 Page2
SUMMARY / INHALTSVERZEICHNIS
Equipment guide for intervention on catenaries
Ausrüstungsleitfaden für den Einstaz an Oberleitungen
Equipment guide for intervention on tramway & trolley installations
Ausrüstungsleitfaden für den Einstaz an Straßen- und S-Bahn -Anlagen
4
6
Equipment guide for intervention on subway installations
Ausrüstungsleitfaden für den Einstaz an U-Bahn -Anlagen8
Equipment guide for lines, substations and installations
Ausrüstungsleitfaden für Freileitungen, Umspannwerke und Elektroanlagen
10
Golden safety rules
Sicherheitsregeln13
Railway division
railways 2012 31/07/12 14:37 Page3
Railway division4
Short-circuitingand earthing
systems
Erdungs- undKurzschließvor-
richtungenVoltage detectorsSpannungsprüfer
EQUIPMENT G
AUSRÜS T
3
2
5
6
6
24C
4C
4A
1
6
9
6
4B
Find these products inthe catalog RAILWAYS
Diese Produkte sind imKatalog RAILWAYS
railways 2012 31/07/12 14:37 Page4
Cables with connections / Kabel mit Anschlüssen
A.C D.C
15 kV 25 kV 1500 V 3000 VReference / Artikelbezeichnung: M-24-35-S - 8 kA/1s, Section / Querschnitt : 35 mm2
Reference / Artikelbezeichnung: M-24-40-S - 10 kA/1s, Section / Querschnitt : 40 mm2
Reference / Artikelbezeichnung: M-24-50-S - 12 kA/1s, Section / Querschnitt : 50 mm2
Accessories / Zubehör : earth flag / Warnzeichen „Erde“ Reference / Artikelbezeichnung : AL-58, AL-60
Reference / Artikelbezeichnung: M-24-70-S - 16 kA/1s, Section / Querschnitt : 70 mm2
Reference / Artikelbezeichnung: M-24-95-S - 20 kA/1s, Section / Querschnitt : 95 mm2
Voltage detectors / Spannungsprüfer *
A.C D.C
15 kV 25 kV 1500 V 3000 V
Electronic voltage detectorElektronischer Spannungsprüfer15 kV 16 Hz 2/3Reference / Artikelbezeichnung :CC-578-15
Electronic voltage detectorsElektronische Spannungsprüfer25 kV 50/60 HzReferences / Artikelbezeichnung :CC-875-25-CCC-875-25-K
Railway detector / Spannungsprüferfür die Bahn 25 kV 50 HzAlternative current catenaryWechselstrom-OberleitungReference / Artikelbezeichnung :ZVATDAC 25 SNCF
Electronic voltage detectorElektronischer Spannungsprüfer600/2000 VReference / Artikelbezeichnung :CC-1515-100
Electronic voltage detectorElektronischer Spannungsprüfer750/1500 VReference / Artikelbezeichnung :ZVATDC 750/1500 W
Electronic voltage detectorElektronischer Spannungsprüfer750/3000 VReference / Artikelbezeichnung :CL6-3000
Bipolar voltage detector with discrimination of induced voltageZweipoliger Spannungsprüfer(ausgeblendete induzierte Span-nungen) : 750/3000 VReference / Artikelbezeichnung :ZVAT DC IND
T GUIDE FOR INTERVENTION ON CATENARIES
S TUNGSLEITFADEN FÜR DEN EINSTAG AN OBERLEITUNGEN
5Railway division* For other voltages, please consult us / Für andere Spannungen bitte melden Sie sich bei uns.
1
Insulating sticks for voltage detectors and short-circuiting systems / Isolierstangen für Spannungsprüfer und Kurzschließvorrichtungen
Insulating sticks with connectable elements Isolierstangen mit anschließbaren TeilenReferences / Artikelbezeichnung :CM-42…. serie CM-4615.. serieCM-43…. serie CM-4620.. serieCM-4610.. serie CM-4625.. serie
Insulating telescopic sticks / Isolier-TeleskopstangenReferences / Artikelbezeichnung : CE-5-50-C, CE-5-50-K, ZPTVZCR 5603 M, ZPTVZCR 5603 B, ZRAVZC 200
Accessories / ZubehörStick bags References / Transporttaschen für Isolierstangen Artikelbezeichnung : CM-1.., CM-2.., CM-3.. series
Short circuiting and earthing systems / Erdungs- und Kurzschließvorrichtungen
Clamps / Klemmen
Universal clamps / UniversalklemmenReferences / Artikelbezeichnung : ZCCVZC 25, ZCCVZC 25 B, ZCCVZC 25 1
Clamps for flat and round conductors / Klemmen für Flachschienen undRundleiterReferences / Artikelbezeichnung : MT-128, MT-815-E
Clamps with or without fuse contact wire / Klemmen mit oder ohne Fahrdraht-SicherungReferences / Artikelbezeichnung : MT-128, ZEMRC 200 B, ZEMRC 201 B
Clamps for single or double catenary / Klemmen für Einzel-oder DoppelOberleitungReference / Artikelbezeichnung : ZEMCC-3162-BC, ZEMRC 300 B,ZEMRC 301 B
Earth clamps / Erdungsklemmen
Earthing rail clamps / Klemmen für ErdungsschienenReferences / Artikelbezeichnung : MT-848, ZSMT-848/100, ZETMRTOP, ZET-62042
Earth clamps for fixed ball points References / Erdungsklemmen für kugelförmige Festpunkte Referenzen : MT-1911, MT-1921, for roundand flat conductor / für Rundeleiter und Flachschienen : MT-843 forclamping on pole / zum Stecken auf Gittermasten Z-EMCT847 SNCF
2
4A4B
4C
5
6 9
3
railways 2012 31/07/12 14:37 Page5
Short-circuiting and earthing systemsErdungs- und Kurzschließvorrichtungen
EQUIPMENT G
6 Railway division
Voltage detectorsSpannungsprüfer
1
4
2
5
3
6
Voltage detectors / Spannungsprüfer Short circuiting and earthing systems / Erdungs- und Kurzschließvorrichtungen
D.C Clamps / Klemmen
750/1500 VAutoclamping contact clamp / Selbst sichernde KlemmenReference / Artikelbezeichnung : ZEMCC 2160
Bipolar electronic voltage detector / Zweipoliger SpannungsprüferReference / Artikelbezeichnung : ZVATDC 750/1500 W
Cables with connections / Kabel mit Anschlüsse
Copper cable with connection / Kupferkabel mit Anschluss - Length /Länge: 2 m, Section / Querschnitt : 35 mm2
Reference / Artikelbezeichnung : ZCESS 35/05 MR
Insulating sticks / Isolierstangen Earth clamps / Erdungsklemmen
For voltage detector / Für SpannungsprüferReference / Artikelbezeichnung: ZPTVZCR 4603 W
For short-circuiting system / Für Erdungs- und Kurzschließvorrich-tungen. Reference / Artikelbezeichnung : ZPL7R 120N
Automatic earth clamps / Selbst sichernde ErdungsklemmenReferences / Artikelbezeichnung : ZETMR 35, ZETRT 35, ZETMR 41,ZETMR RG29, ZETMR UNIV
14
5
6
2
3
railways 2012 31/07/12 14:37 Page6
7Railway division
T GUIDE FOR INTERVENTION INSTALLATIONS
AUSRÜSTUNGSLEITFADEN FÜR DEN EINSTAZ
ON TRAMWAY & TROLLEY
AN STRASSEN- UND S-BAHN -ANLAGEN
Voltage detectorsSpannungsprüfer
Short-circuiting systemsErdungsvorrichtungen
Voltage detectors / Spannungsprüfer Short circuiting / Erdungsvorrichtungen
D.C Clamps / Klemmen
750 VAutoclamping contact clamp / Selbst sichernde KlemmenReference / Artikelbezeichnung : ZCCVZC 25
Bipolar electronic voltage detector / Zweipoliger SpannungsprüferReference / Artikelbezeichnung : ZVDCAL 750 TROL
Cables with connections / Kabel mit Anschlüsse
Copper cable with connection / Kupferkabel mit Anschluss,For instance / Zum Beispiel : Length / Länge: 2 m, Section / Querschnitt :50 mm2
Reference / Artikelbezeichnung : M2450SInsulating sticks / Isolierstangen
For voltage detector / Für SpannungsprüferReference / Artikelbezeichnung : ZPTVZCR 5603 B
For short-circuiting system / Für Erdungsvorrichtungen Reference / Artikelbezeichnung : ZPTVZCR 5603
14
5
2
3
Find these products inthe catalog RAILWAYS
Diese Produkte sind imKatalog RAILWAYS
4
5
3
2
1
railways 2012 31/07/12 14:37 Page7
EQUIPMENT GUIDE F
AUSRÜS T
8 Railway division
* For special specification, please consult us / Für besondere Spezifikation, bitte melden Sie sich bei uns.
Short-circuiting and earthing systemsErdungs- und Kurzschließvorrichtungen2
43
5
1Voltage detectorsSpannungsprüfer
Find these products inthe catalog RAILWAYS
Diese Produkte sind imKatalog RAILWAYS
railways 2012 31/07/12 14:37 Page8
9Railway division
E FOR INTERVENTION ON SUBWAY INSTALLATIONS
S TUNGSLEITFADEN FÜR DEN EINSATZ AN U-BAHN-ANLAGEN
Voltage detectors / Spannungsprüfer Short circuiting and earthing systems / Erdungs- und Kurzschließvorrichtungen
D.C Clamps / Klemmen
750 VClamp for side conductor / Klammer für SeitenleiterReference / Artikelbezeichnung : MT-1921
Bipolar electronic voltage detector / Zweipoliger SpannungsprüferReference / Artikelbezeichnung : CL-1607/1, CL-1607/ML
Cables with connections / Kabel mit Anschlüsse
Copper cable with connection / Kupferkabel mit Anschluss - For instance /Zum Beispiel : Length / Länge : 3 m, Section / Querschnitt : 50 mm2
Reference / Artikelbezeichnung : M2450S
Earthing equipement / Erdungsvorrichtung Earth clamps / Erdungsklemmen
Earthing clamp for connection to the third rail / Erdungsklemme zurVerbindung mit der dritten SchieneReference / Artikelbezeichnung : ZET 3R
Earthing rail equipment for third rail configuration / Erdungsschiene-Ausrüstung für die dritte Schiene Konfiguration 85kA/30ms Reference / Artikelbezeichnung : MT-300
Earth clamp for rail / Schienen-ErdungsklemmenReferences / Artikelbezeichnung : ZSMT 848/100
12
4
3
5
6
1
6 5
railways 2012 31/07/12 14:37 Page9
EQUIPMENT G U
AUSRÜSTUNGSLEITFADE N F
Railway division10
Substation with bare conductorsUmspannwerk mit blanken Leitern
1513 1
1015
12
15
15
16
9
6
4
7
Short-circuiting and earthing systems
Erdungs- und Kurzschließvorrichtungen
Voltage detectorsSpannungsprüfer
Phase comparatorPhasenvergleicher
Voltage detectors and phase comparatorsSpannungsprüfer und Phasenvergleicher
Short circuiting and earthing systemsErdungs- und Kurzschließvorrichtungen
Voltage detectors for indoor use / Innenraum-Spannungsprüfer 5-40 kV Reference / Artikelbezeichnung : CL-4, CL-2 series
Voltage detector for separable connectors / Spannungsprüfer fürSteckendverschlüsseReference / Artikelbezeichnung : CC-151-K
Phase comparators, two poles or single pole / Einpoliger oder zweipoliger PhasenvergleicherReference / Artikelbezeichnung : CL-5, CL-8, CL-7 series
Permanent luminous voltage indicator / Permanenter SpannungsanzeigerReference / Artikelbezeichnung : CL-40010
Integrated systems VIS VDS / Integriertes SpannungsprüfsystemReference / Artikelbezeichnung : CL-495, CL497, CL-498
Short-circuiting system for MV substations / Erdungs- und Kurzschließvorrichtungen für MS-Schaltanlagen :- And for installation on permanent fixed points / Und für Festpunkte Reference / Artikelbezeichnung : MT-1910/MT-1920
- Or for installation on bare conductors / Oder für blanke LeiterReference / Artikelbezeichnung : MT-5805/MT-9801
Fixed points / Festpunkte Reference / Artikelbezeichnung : MT-2950/MT-3950 series
1
2
3
4
5
6
7
3
railways 2012 31/07/12 14:37 Page10
131
1015
12
16
11
2
Voltage detectorsSpannungsprüfer
14
5
Railway division 11
G UIDE FOR LINES, SUBSTATIONS AND INSTALLATIONS
E N FÜR FREILEITUNGEN, UMSPANNWERKE UND ELEKTROANLAGEN
Substation with semi-automatic switchgear and metalclad switchgearUmspannwerk mit halbautomatischer Schaltanlage und Metalclad Schaltgeräte
15
Insulating sticks / Isolierstangen Protective equipment / Persönliche Schutzausrüstung
Voltage detectors for MV separable connectors & stick for indoor use5-40 kV / Innenraum Spannungsprüfer für Steckendverschlüsse undStange Nennspannung 5-40 kVReference / Artikelbezeichnung : CC-151-K, CC45K
Insulating sticks for subsations use IEC-61235 / Isolierstangen nach IEC-61235 für SchaltanlagenReference / Artikelbezeichnung : CF-5-40/CE-4-21...
Insulating rubber gloves 26.5 kV with storage box / IsolierendeGummihandschuhe 26,5 kV mit AufbewahrungsboxReference / Artikelbezeichnung : CG-30/CG-35/2
Insulating Platform 24 kV / Isolierhocker 24 kVReference / Artikelbezeichnung : CT-7-25/1
Insulating mat 26.5 kV / Isoliermatte 26,5 kVReference / Artikelbezeichnung : MP-42/11
Rescue stick 45 kV / Rettungsstange 45 kVReference / Artikelbezeichnung : CS-45
Warning signs and accessories / Warnschilder und Zubehör
Warning signs in aluminium / Warnzeichen aus AluminiumReference / Artikelbezeichnung : AM-49/1, AM-344-GB
Specialised signs / SonderzeichenReference / Artikelbezeichnung : AP-510-GB/AM-20-GB
Fuse holder / WandsicherungshalterReference / Artikelbezeichnung : CI-23
8
9
14
15
16
10
11
12
13
Find these products inthe catalog RAILWAYS
Diese Produkte sind imKatalog RAILWAYS
8
9
railways 2012 31/07/12 14:37 Page11
EQUIPMENT G UID E FOR LINES, SUBSTATIONS AND INSTALLATIONS
AUSRÜSTUNGSLEITFADEN FÜR FREILEITUNGEN, UMSPANNWERKE UND ELEKTROANLAGEN
Railway division12
Short-circuiting and earthing systemsErdungs- und
Kurzschließvorrichtungen
25
4
9
1
6
7
8
Earth Clamps, rod and flags / Erdungsklemmen, Stab und Warnzeichen Protective equipment / Persönliche Schutzausrüstung
Earth Clamps / ErdungsklemmenReference / Artikelbezeichnung : MT-847, MT-843
Earth Flags / Warnzeichen „Erde“ Reference / Artikelbezeichnung : AL-58, AL-60
IEC Insulating Sticks for short-circuiting systems and Voltage detectors / Erdungs- und Betätigungsstangen nach IECReference / Artikelbezeichnung : CM-4000 serie
Insulating sticks for short circuiting and earthing systemIsolierstangen für Erdungs- und KurzschließvorrichtungenReference / Artikelbezeichnung : CM-6 serie
Connection adaptors / AnschlussadapterReference / Artikelbezeichnung : CI-.. serie
Insulating platform / Isolierhocker
Insulating platform outdoor use Freiluft-IsolierhockerReference / Artikelbezeichnung : CT-9-63
4
5
9
6
7
8
Voltage detectors and phase comparatorsSpannungsprüfer und Phasenvergleicher
Short circuiting and earthing systems / Erdungs- und Kurzschließvorrichtungen
Electronic voltage detectors IEC or standard / Elektronischer Spannungsprüfer nach IEC oder anderen NormenReference / Artikelbezeichnung : CC-245 serie
Phase clamps / PhasenklemmenReference / Artikelbezeichnung : MT-730 serie
Cables (copper) / Kabel (Kupfer)Reference / Artikelbezeichnung : M-24-... series
1
Find these products inthe catalog RAILWAYS
Diese Produkte sind imKatalog RAILWAYS
HV substation line (work from ground)Umspannwerk-Freileitung (Arbeit vomBoden aus)
2
3
3
Voltage detectorsSpannungsprüfer
railways 2012 31/07/12 14:43 Page12
SHOWN, WARN OTHERS AND LIMIT THEWORK AREA even during the most simpletemporary maintenance operation.
BENACHBARTE, UNTER SPANNUNG STEHENDE TEILE ABDECKEN ODER ABSCHRANKEN.
5
13Railway division
GOLDEN SAFETY RULESSICHERHEITSREGELN
SEPARATE THE WORK AREA FROM ALLPOSSIBLE SOURCES OF POWER-SUPPLYby opening circuit-breakers, switches.
FREISCHALTEN.
1
LOCK THE LINKS IN THE OPEN POSITION.
GEGEN WIEDEREINSCHALTEN SICHERN.
2
CHECK THE ABSENCE OF VOLTAGE atsource and on site, on each conductorand apparatus involved.
SPANNUNGSFREIHEIT FESTSTELLEN.
3
APPLY APPROPRIATE SHORT-CIRCUIT AND EARTHING SYSTEMS in sufficient numberson the conductors of your network whereoperation is taking place.
ERDEN UND KURZSCHLIESSEN.
4
FIRST, SELECT THE RIGHTEQUIPMENT.
DER ANWENDER HAT DIE FORDERUNGEN DER BG UNDDIN VDE 0105 TEIL 100 ZUBEACHTEN (persönliche Schutzausrüstung).
railways 2012 31/07/12 14:38 Page13
VOLTAGE DETECTORS for l ines and catenar ies
SPANNUNGSPRÜFER FÜR Frei le i tungen und Ober le i tungen
Railway division
railways 2012 31/07/12 14:38 Page14
Find these products in
the catalog rAiLWAYS
Diese Produkte findenSie auf dem Katalog
RAILWAYS
Join us on / MeldenSie sich bei uns auf :
www.catuelec.com
© 2012 CATU S.A. BAGNEUX
All rights of reproduction (in full or part), adaptation and translation reserved for any country. Alle Rechte der Reproduktion (vollständig oder teilweise), Anpassung und
Übersetzung für alle Länder vorbehalten. PriNTEd iN FrANCE / IN FRANKREICH GEDRUCKT.
Conception : ComST
Scan
qr /
Sca
nnen
QR
railways 2012 31/07/12 14:38 Page15