qma2030 process moisture analyzer - michell instruments• electronic gases • air separation...

4
www.michell.com Process Moisture Analyzers QMA2030 Process Moisture Analyzer A high-precision, fast-responding analyzer with automatic calibration for a wide range of applications from high purity industrial gases to catalyst bed protection. The QMA2030 Moisture Analyzer uses Advanced Quartz Crystal Microbalance technology for drift-free measurements with low sensitivity to contamination. Highlights • High accuracy 5% in the range 0.5 to 500 ppm V Wide operating range 0.1 to 2000 ppm V • Extremely fast less than 2 minutes for 63% response to a step change in either direction Quartz Crystal Microbalance technology for drift-free measurements with low sensitivity to contamination • Automatic calibration for measurement confidence • Intuitive touch-screen easy to use front panel display Low cost of ownership simple maintenance Applications High purity gas production Industrial gas production Electronic gases Air separation plants Catalyst bed protection Semiconductor grade gases Cylinder gases Specialty gases Process dryers Hydrocarbon gases And many more...

Upload: others

Post on 08-Mar-2021

36 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QMA2030 Process Moisture Analyzer - Michell Instruments• Electronic gases • Air separation plants • Catalyst bed protection • Semiconductor grade gases • Cylinder gases •

www.michell.com

Process Moisture Analyzers

QMA2030Process Moisture AnalyzerA high-precision, fast-responding analyzer with automatic calibration for a wide range of applications from high purity industrial gases to catalyst bed protection.

The QMA2030 Moisture Analyzer uses Advanced Quartz Crystal Microbalance technology for drift-free measurements with low sensitivity to contamination.

Highlights• High accuracy

5% in the range 0.5 to 500 ppmV

• Wide operating range0.1 to 2000 ppmV

• Extremely fastless than 2 minutes for 63% response to a step change in either direction

• Quartz Crystal Microbalance technology for drift-free measurements with low sensitivity to contamination

• Automatic calibration for measurement confi dence

• Intuitive touch-screen easy to use front panel display

• Low cost of ownershipsimple maintenance

Applications• High purity gas production

• Industrial gas production

• Electronic gases

• Air separation plants

• Catalyst bed protection

• Semiconductor grade gases

• Cylinder gases

• Specialty gases

• Process dryers

• Hydrocarbon gases

• And many more...

Page 2: QMA2030 Process Moisture Analyzer - Michell Instruments• Electronic gases • Air separation plants • Catalyst bed protection • Semiconductor grade gases • Cylinder gases •

www.michell.com

Process Moisture Analyzers

QMA2030 Process Moisture AnalyzerThe QMA2030 Process Moisture Analyzer is designed to provide a highly reliable, fast and accurate measurement of trace levels of moisture content (ppbV and ppmV) in a wide variety of industrial applications where the direct measurement of true concentration of water molecules is of concern. The applied quartz crystal microbalance technology can directly measure the volume concentration of water as an impurity in a process gas.

For self-verifi cation and diagnostics the analyzer incorporates automatic calibration using an internal reference source. The intuitive touch screen control panel provides easy operation. In addition, live measurement data and system information is always on view and the analyzer also has a data logging facility that allows trend data to be downloaded to an external storage device via USB, for analysis. On-screen alarms can be set at user defi ned levels. Alarm contacts, and a 4-20mA analog output are provided for connection to external monitoring.

FeaturesWide operating range helps control processes

The wide operating range – from 0.1 to 2000 ppmV – and fast response of the QMA2030 helps users to monitor and protect processes. A high moisture event can damage processing tools or fi nished products. It can indicate a failure upstream in air and gas separation plants. The QMA2030 can track high moisture events in real time and help quantify the size and duration of a moisture excursion, provide important information on gas delivery systems and even help prevent moist gas from reaching critical parts of the process.

Outstanding accuracy

Michell’s advanced quartz crystal technology, developed and refi ned over many years, provides a highly reproducible and linear response to changes in moisture content. This allows the QMA2030 to deliver class-leading accuracy of 5% of measured value in the range 0.5 to 500 ppmV.

Excellent response speed through innovative engineering

Traditional sensor technologies are slow to respond in the trace moisture region. The QMA2030 is different. The highly responsive sensor, coupled with a volume-optimized internal sampling system means that the QMA2030 will give a 63% response to a step change in moisture in less than 2 minutes. This is more than twice the speed of comparable QCM analyzers. 95% response is achieved in less than 5 minutes, as the graph below left demonstrates.

Advanced quartz crystal microbalance technology

Michell’s engineers have spent many years developing and optimizing the performance of the Michell QCM sensor. This new generation sensor provides improved response, reproducibility and lower sensitivity to contamination than other available trace moisture analyzers. Water molecules are adsorbed into

the moisture sensitive layer deposited on the crystal surface and the resulting change in mass modifi es, in a very precise and repeatable manner, the frequency of oscillation. The design and manufacturing quality of the Michell QCM sensor is the key to the high performance level of the QMA2030.

Automatic calibration for complete measurement confi dence

The QMA2030 incorporates a fully automatic, self-contained calibration system for complete user confi dence. The internal gas handling circuit comprises a gas dryer, moisture generator,

sensor block sample housing and sensor cell, along with capillary fl ow control, fl ow meter and solenoid valves. The critical components – moisture generator, sensor and fl ow parts – are accurately temperature-controlled. Periodic

1

6

7

8 8 8IN

V1 V2 V3

OUT25

3

4

1 Dryer 2 Flow meter 3 Quartz crystal sensor 4 Quartz crystal reference 5 Oven

KEY 6 Moisture generator 7 Sensor block 8 Capillary V1, V2, V3 Solenoid valves

0

1

2

3

4

7

8

9

10

11

0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00

ppm

v

Time (min)

QMA2030 Response Speed

T63 in 1 min 5 sec

T63 in 1 min 20 sec

6

5

Page 3: QMA2030 Process Moisture Analyzer - Michell Instruments• Electronic gases • Air separation plants • Catalyst bed protection • Semiconductor grade gases • Cylinder gases •

www.michell.com

Process Moisture Analyzers

Ordering information

Order code Description

QMA-2030 QMA2030 base unit with LCD display and inbuilt data logging

Accessories

Order code Description

QMA-BFM Flow meter calibration kit (for optimum measurement accuracy)

QMA-VCR-8th Inlet adapter: ¼ VCR to ⅛” adapter

QMA-IPR Inlet pressure regulator

calibration checks of sensor performance can be initiated automatically (at user defi ned intervals and time of day) or manually on demand, providing a zero and span verifi cation of instrument performance and automatically adjusting out any change. The moisture generator is calibrated traceable to NIST or other National Standards.

User friendly operation – precision made easy

Michell Instruments continues to stretch the boundaries in moisture measurement technology, providing innovative

solutions that improve process effi ciency and are simple to use. The QMA2030 touch-sensitive LCD display has been tested and endorsed by leading industrial gas manufacturers who value the easy set-up, control, display and data logging features of the instrument. Not only can users view live data and graphical trends on screen, but up to 14,000 measurement points, with varying time intervals, can be logged and downloaded to a PC via USB for further analysis.

Simple maintenance – reduced lifetime cost

Sophisticated instruments are often complicated and require experience and special care in use, increasing cost of ownership. Michell Instruments focuses not only on ease of operation, but ease and cost-effectiveness of maintenance. The QMA2030 is designed such that the

integrated sensor block, shown here, can be replaced in just a few simple steps, even by less experienced staff, in the event that it needs to be factory calibrated to maintain traceability to NIST or other national standards.

QMA solutions for hazardous area and specialist applications

Specifi c applications require specialized analyzer solutions. The QMA2020 provides all the functionality and performance of the QMA2030 and is approved for operation in hazardous area applications. Other specialist solutions are available – consult your Michell representative for further information.

Page 4: QMA2030 Process Moisture Analyzer - Michell Instruments• Electronic gases • Air separation plants • Catalyst bed protection • Semiconductor grade gases • Cylinder gases •

Michell Instruments adopts a continuous development programme which sometimes necessitates specifi cation changes without notice.Issue no: for layout purposes only. QMA2030_97148_V3_US_1209

© 2010 Michell Instruments

Michell Instruments, Inc, 319 Newburyport Turnpike, Suite 207, Rowley, MA 01969Tel: 978 484 0005, Fax: 978 843 7669, Email: [email protected], Web: www.michell.com/us

Process Moisture Analyzers

Technical Specifi cationsPerformanceMeasurement technology

Quartz Crystal Microbalance

Range 0.1 to 2000ppmV. Calibrated range 0.5 to 500ppmV with trend indication above and below calibration range

Accuracy ±5% for 0.5 to 500 ppmV or 0.1 ppmV whichever is greater

Repeatability ±5% of the reading from 0.5 to 1000ppmV

Sensitivity 0.1ppmV or 1% of the reading, whichever is the greater

Response time <2 minutes for 63% response to a step change in either direction<5 minutes for 95% response to a step change in either direction

Automatic calibration

Internal moisture generator source calibrated traceable to NIST

Electrical output/inputAnalog output 4–20mA for moisture (max load 500Ω) User-confi gurable

range

Analog output resolution

16 bit

Supply voltage 110V (90 to 115) or 240V (220 to 245) switch selectable, 50-60Hz

Alarms 3 Alarms: Volt free contact, rating 3A@250 VAC

27/04/09RLS

PMA 2030

N/A

90434SHEET 1 OF 2

1:1SCALE

SIGN

A2

DATEMOD. No.ISSUEDRAWING NUMBER

TOLERANCES: UNLESS OTHERWISE STATED

FINISH

DIMENSIONS:

MATERIAL

TITLE

USED ON

APPROVEDCHECKED

DATEDATE

DRAWN

DATEMICHELL INSTRUMENTS LTD. 18/05/07 DOF02

mmTHIS DOCUMENT IS THE PROPERTY OF MICHELL INSTRUMENTS LTD.

AND MUST NOT BE COPIED NOR DISCLOSED TO A THIRD PARTYWITHOUT THE CONSENT OF MICHELL INSTRUMENTS.

PMA 2030 GENERAL ASSEMBLY

3rd ANGLEPROJECTION

N/A

DRAWINGUNITS

4 Inches

100mm

ANGLES: ±0.5°

HOLE Ø:+0.1-0.1

0 DEC. PLACE: ± 0.51 DEC. PLACE: ± 0.22 DEC. PLACE: ± 0.1

A ------- 27/04/09 RLS

MICHELL INSTRUMENTS LTD. ELY © 2007

01 ------- 25/06/09 RMS

18.5"/470 mm8.

4"/2

14 m

m15.7"/400 mm

6.8"/172 mm

5.1"/1

29 m

m

Dimensions

27/04/09RLS

PMA 2030

N/A

90434SHEET 1 OF 2

1:1SCALE

SIGN

A2

DATEMOD. No.ISSUEDRAWING NUMBER

TOLERANCES: UNLESS OTHERWISE STATED

FINISH

DIMENSIONS:

MATERIAL

TITLE

USED ON

APPROVEDCHECKED

DATEDATE

DRAWN

DATEMICHELL INSTRUMENTS LTD. 18/05/07 DOF02

mmTHIS DOCUMENT IS THE PROPERTY OF MICHELL INSTRUMENTS LTD.

AND MUST NOT BE COPIED NOR DISCLOSED TO A THIRD PARTYWITHOUT THE CONSENT OF MICHELL INSTRUMENTS.

PMA 2030 GENERAL ASSEMBLY

3rd ANGLEPROJECTION

N/A

DRAWINGUNITS

4 Inches

100mm

ANGLES: ±0.5°

HOLE Ø:+0.1-0.1

0 DEC. PLACE: ± 0.51 DEC. PLACE: ± 0.22 DEC. PLACE: ± 0.1

A ------- 27/04/09 RLS

MICHELL INSTRUMENTS LTD. ELY © 2007

01 ------- 25/06/09 RMS

18.5"/470 mm

8.4"

/214

mm

15.7"/400 mm

6.8"/172 mm

5.1"/1

29 m

m

Operating conditionsInlet pressure 15 psig (Adjusted to achieve the correct exhaust fl ow, up

to 1500 psig with optional pressure regulator)

Outlet pressure Atmospheric

Sample fl ow requirement

3.6 in³/hr or 300ml/min

Sample gas temperature

0°C to 100°C / 32°F to 212°F

Operating environment

15°C to 40°C / 59°F to 104°F , 90%RH max

Mechanical specifi cationDisplay 8.4 inch LCD touch-screen

Dimensions (WxHxD)

18.5 inches x 8.4 inches x 15.7 inches – allow extra 7.5 inches for clearance at back (w x h x d)470mm x 214mm x 400mm – allow extra 200mm for clearance at back (w x h x d)

Net weight 33lbs / 15kg