protector series standby generators protector

of 11/11
1 of 11 INCLUDES: • Two-Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position. • Capability to be installed with 18" (457mm) of a building* • True Power™ Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible. Standby Power Rating Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz PROTECTOR ® SERIES Standby Generators Liquid-Cooled Gaseous Engine Protector ® Series Protector ® Series Meets EPA Emission Regulations 25, 30 & 45 kW CA/MA emissions compliant 36 & 60 kW not for sale in CA / MA ¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TEST CRITERIA: aPROTOTYPE TESTED aNEMA MG1-22 EVALUATION aSYSTEM TORSIONAL TESTED aMOTOR STARTING ABILITY ¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. FEATURES *Assembled in the USA using domestic and foreign parts ISO 9001: 2008 *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only.

Post on 05-Nov-2021

6 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

• Capability to be installed with 18" (457mm) of a building*
• True Power™ Electrical Technology
• 5 Year Limited Warranty
• UL 2200 Listed
Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible.
Standby Power Rating
Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz
PROTECTOR® SERIES Standby Generators
Protector® Series
Meets EPA Emission Regulations 25, 30 & 45 kW CA/MA emissions compliant
36 & 60 kW not for sale in CA / MA
¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
¡ TEST CRITERIA: a PROTOTYPE TESTED a NEMA MG1-22 EVALUATION a SYSTEM TORSIONAL TESTED a MOTOR STARTING ABILITY
¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
FEATURES
ISO 9001: 2008
*Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only.
2 of 11
GENERATOR SPECIFICATIONS Type Synchronous
Rotor Insulation Class H
Stator Insulation Class H
Alternator Output Leads 1-Phase 4 wire
Alternator Output Leads 3-Phase 6 wire
Bearings Sealed Ball
Coupling Flexible Disc
Excitation System Direct
Battery Charge Alternator 12 Volt 15 Amp - 25 & 30 kW
12 Volt 30 Amp - 36, 45 & 60 kW
Static Battery Charger 2 Amp
Recommended Battery (battery not included) Group 26, 525CCA
System Voltage 12 Volts
GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated All models fully prototyped tested
ENCLOSURE FEATURES
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractive Makes for an easy, eye appealing installation.
SAE Sound attenuated enclosure ensures quiet operation.
ENGINE SPECIFICATIONS: 25 & 30 kW Make Generac
Model In-line
Cylinders 4
Lifter Type Hydraulic
Model In-line
Cylinders 4
Turbocharged/Aftercooled (60 kW)
Lifter Type Hydraulic
Crankcase Capacity (qt/l) 4/3.8 - 25, 30, 36 & 45 kW
5.25/4.96 - 60 kW
Water Pump Belt driven
22/558.8 (36, 45 & 60 kW)
Fan Mode Pusher (25 & 30 kW) or
Puller (36, 45 & 60 kW)
FUEL SYSTEM Fuel Type Natural gas, propane vapor
Carburetor Down Draft
Operating Fuel Pressure 5-14" water column/9-26 mm HG
LP Fuel Pressure 11 - 14" Water Column
NG Fuel Pressure 5 - 14" Water Column (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
P ro
te ct
or ® S
er ie
25 • 30 • 36 • 45 • 60 kW operating data
GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)
RG025
120/240 V, 1Ø, 1.0 pf 25 104 25 104 125
120/208 V, 3Ø, 0.8 pf 25 87 25 87 100
120/240 V, 3Ø, 0.8 pf 25 75 25 75 90
RG030
120/240 V, 1Ø, 1.0 pf 30 125 30 125 150
120/208 V, 3Ø, 0.8 pf 30 104 30 104 125
120/240 V, 3Ø, 0.8 pf 30 90 30 90 100
RG036
120/240 V, 1Ø, 1.0 pf 36 150 36 150 175
120/208 V, 3Ø, 0.8 pf 36 125 36 125 150
120/240 V, 3Ø, 0.8 pf 36 108 36 108 125
277/480 V, 3Ø, 0.8 pf 36 54 36 54 60
RG045
120/240 V, 1Ø, 1.0 pf 45 188 45 188 200
120/208 V, 3Ø, 0.8 pf 45 156 45 156 175
120/240 V, 3Ø, 0.8 pf 45 135 45 135 150
277/480 V, 3Ø, 0.8 pf 45 68 45 68 80
RG060
120/240 V, 1Ø, 1.0 pf 60 250 60 250 300
120/208 V, 3Ø, 0.8 pf 60 208 60 208 250
120/240 V, 3Ø, 0.8 pf 60 180 60 180 200
277/480 V, 3Ø, 0.8 pf 60 90 60 90 100
SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf
15% 30%
RG030
RG036
RG045
RG060
ENGINE FUEL CONSUMPTION Natural Gas Propane
(ft³/hr) (m³ /hr) (gal/hr) (l/hr) (ft³/hr)
RG025
25% of rated load 220 6.3 2.9 9.1 88
50% of rated load 297 8.4 3.3 12.3 119
75% of rated load 362 10.3 4 15 145
100% of rated load 430 12.2 4.7 17.8 172
RG030
25% of rated load 240 6.8 2.6 10 96
50% of rated load 320 9.1 3.5 13.3 128
75% of rated load 400 11.4 4.4 16.6 160
100% of rated load 492 14 5.4 20.4 197
RG036
25% of rated load 210 6 2.3 8.6 83
50% of rated load 380 10.8 4.2 15.7 151
75% of rated load 545 15.5 5.9 22.4 216
100% of rated load 730 20.7 8 30.1 290
RG045
25% of rated load 210 6 2.3 8.6 83
50% of rated load 380 10.8 4.2 15.7 151
75% of rated load 545 15.5 5.9 22.4 216
100% of rated load 730 20.7 8 30.1 290
RG060
25% of rated load 267 7.6 2.7 10.5 101
50% of rated load 483 13.7 5 19 183
75% of rated load 672 19.1 7 26.5 255
100% of rated load 862 24.5 9 33.9 327
P ro
te ct
or ® S
er ie
s
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG)
For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.
4 of 11
P ro
te ct
or ® S
er ie
Temperature Deration ...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (25, 30, 36 & 45 kW) ...............................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (60 kW) ................................................................................................ 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
CONTROLLER FEATURES
Programmable start delay between 10-30 seconds .................................................................................................................................................10 sec Standard Engine Start Sequence ..................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up ..................................................................................................................................................................................................................... 5 sec Engine Cool-Down ..................................................................................................................................................................................................................1 min Starter Lock-out ................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger ........................................................................................................................................................................................................ Standard Automatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................ Standard Automatic Low Oil Pressure Shutdown ............................................................................................................................................................................... Standard Overspeed Shutdown .............................................................................................................................................................................................. Standard, 72 Hz High Temperature Shutdown ............................................................................................................................................................................................... Standard Overcrank Protection .......................................................................................................................................................................................................... Standard Safety Fused ...................................................................................................................................................................................................................... Standard Failure to Transfer Protection .............................................................................................................................................................................................. Standard Low Battery Protection ........................................................................................................................................................................................................ Standard 50 Event Run Log ............................................................................................................................................................................................................... Standard Future Set Capable Exerciser .............................................................................................................................................................................................. Standard Incorrect Wiring Protection ................................................................................................................................................................................................. Standard Internal Fault Protection ..................................................................................................................................................................................................... Standard Common External Fault Capability ...................................................................................................................................................................................... Standard Governor Failure Protection ................................................................................................................................................................................................ Standard
ENGINE COOLING
25 kW 30 kW 36 kW 45 kW 60 kW
Air flow (inlet air including alternator and combustion air in cfm/cmm) 2490/70.5 2490/70.5 2725/77.2 2725/77.2 3280/92.9
System coolant capacity (gal/liters) 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5
Heat rejection to coolant (BTU per hr/MJ per hr) 112,000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9
Maximum operation air temperature on radiator (°C/°F) 60/140
Maximum ambient temperature (°C/°F) 50/122
COMBUSTION REQUIREMENTS
Flow at rated power (cfm/cmm) 62/1.8 72/2 144/4.1 144/4.1 180/5.1
SOUND EMISSIONS
Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 59 59 61 61 65
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 72 73 70 73 72
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
EXHAUST
Exhaust flow at rated output (cfm/cmm) 203/5.7 237/6.7 300/8.5 420/11.9 494/14
Exhaust temperature at muffler outlet (°C/°F) 593/1100 610/1130 579/1075 593/1100 566/1050
ENGINE PARAMETERS
P ro
te ct
or ® S
er ie
Model # Product Description
G006463-4 Mobile Link™
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only.
G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™.
G006175-0 - 25 & 30 kW
G005630-1 - 36, 45 & 60 kW Cold Weather Kit
If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap.
G006174-0 - 25 & 30 kW
G005616-0 - 36, 45 & 60 kW Extreme Cold Weather Kit
Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only.
G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris.
G005703-0 - Bisque Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure.
G006176-0 - 25 & 30 kW
G006172-0 - 36 & 45 kW
G006171-0 - 60 kW
Scheduled Maintenance Kit
The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators.
G006664-0 Local Wireless Monitor
G006665-0 Wireless Remote Extension Harness
Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater.
G006873-0 Smart Management Module (50 Amps)
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system.
G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.
G007005-0 Wi-Fi LP Fuel Level Monitor
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank’s fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill.
6 of 11
P ro
te ct
or ® S
er ie
14 90
[5 8.
7] T
Y P
P ro
te ct
or ® S
er ie
8 of 11
P ro
te ct
or ® S
er ie
75 8
[2 9.
8] D
O O
R T
Y P
44 3
[1 7.
P ro
te ct
or ® S
er ie
10 of 11
35 7
[1 4.
60 kW installation layout
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0L0037SBY-L 9/25/17
17 33
[6 8.