proporcional _control valve _air _datasheet

8
317-335-2602 P.O. Box 218 McCordsville, Indiana 46055 www.proportionair.com THE FUTURE OF CONTROL TM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

Upload: william-roa

Post on 10-Sep-2015

5 views

Category:

Documents


1 download

DESCRIPTION

Válvulas de Control de Aire

TRANSCRIPT

  • 317-335-2602 P.O. Box 218 McCordsville, Indiana 46055 www.proportionair.com

    THE FUTURE OF CONTROLTM

    MM1/MM2CONTROL VALVESCLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

  • PROPORTION-AIR 317-335-2602

    BENEFITS

    FEATURES PERFORMANCE CHARACTERISTICSAPPLICATIONS UniversalMountingDinRail,PanelMount,orSub-baseManifoldMount

    Smallandcompact Fastandaccurate Mountsinanyposition Unaffectedbysupplypressurechanges Non-airconsuminginsteadystate

    Takesuplessspace Reducesplumbing Simplifiesdesign Easytuningofsystemstability

    ManufacturingandAutomation Instrumentation Medical ProcessControl Robotics TestandMeasurement

    Commonsupplyportonsub-basemanifold Fieldserviceable Jumperselectablecommand0-10VDC,4-20mA Adjustablehysteresisband Interfaceswithavarietyofcontrolleroutputs 0-10VDCand4-20mAanalogoutput

  • 317-335-2602 PROPORTION-AIR

    FEATURES

    FUNCTIONAL DESCRIPTION

    PERFORMANCE CHARACTERISTICS

    APPLICATIONS

    TheMMseriesproportionalcontrolvalvesutilizeProportion-Airs unique closed loop controltechnology for superior control of pressurizedgases and fluids. The MM is designed to haveUniversal Mounting capabilities which includeDinRail, panelmount, ormanifoldmounting foruse on sub-base for multiple unit applications.Sub-baseconfigurationsareavailable from2-12units.Thesub-baseoffersacommonsupplyandexhaust port with individual controlled outletportstominimizeplumbingconnections.

    The MM series units can be built as singleclosedloopordualclosedloop(cascadingloop)control valves. The MM1 and MM2 deliverpressurecontrolwhich is linearlyproportional toeither a DC current or DC voltage commandinput.The MM1 uses two solenoid valves to controlsystempressure.Onevalvefunctionsasaninletcontrol,theotherasanexhaustcontrol.Astraingaugepressuretransducermeasuresthesystempressure and provides a feedback signal to theelectronic controls. This feedback signal iscompared against the command signal. Any difference between the two signals causes one of the solenoid valves to open allowing pressure in or out of the system.

    Closed loop proportional control of pressure ismaintainedinthismanner.

    The MM2 is similar to the MM1 but uses adouble loop control scheme. In addition to theinternal pressure transducer, the MM2 alsoreceivesafeedbacksignal(0-10VdcStandard)fromanexternalsensingdevice.

    The external signal functions as the primaryfeedback and is compared to the commandsignal. This comparison is summed with theinternal pressure transducer signal. A difference between the two comparisons causes one of the two solenoid valves to open allowing flow in or out of the system.

    Since the secondary feedback is an electricalsignal,manytypesofsensorsmaybeusedasafeedback such as force, position, pressure,vacuum,etc.Ananalogoutput isalsostandardonboththeMM1andMM2tobeusedfordataacquisition or to a panel meter for display.The analog monitor signal is taken from theinternalpressuresensoronMM1sandfromthesecondaryfeedbackontheMM2.

    LINEARITY RESPONSE TO STEP INPUT

    Fig.1ThischartshowslinearcharacteristicsofMM products when given a ramp signal from0-10volts.Characteristicswouldbesimilar for4-20mAunits.

    Fig. 2 Times for MM to fi ll/exhaust a closedchamber. Step command signal issuperimposed over pressure trace. Time isdetermined by difference between commandsignalandpressureachieved.

  • PROPORTION-AIR 317-335-2602

    NOTES:Dimensionsareinches(mm)DimensionsareforreferenceuseAllportsare1/8-27NPTF

    MANIFOLD MOUNT

    DIMENSIONS

    PANEL MOUNT

    TYPICAL SUB-BASE APPLICATION

    GENERAL SPECIFICATIONSDIN RAIL MOUNT

  • 317-335-2602 PROPORTION-AIR

    DIMENSIONS

    TYPICAL SUB-BASE APPLICATION

    GENERAL SPECIFICATIONSELECTRICALSupplyVoltage15-24VDCSupplyCurrent250mAmax(perunit)CommandSignal

    Voltage0-10VDCCurrent4-20mAdifferential

    2ndLoopInput0-10VDC MonitorSignal0-10or 4-20mA CommandSignalImpedance

    Voltage4700Current100

    2ndLoopSignalImpedance4700 MonitorSignal0-10VDC@10mA PHYSICALOperatingTemp32-158F[0-70C] Weight7lb[.3kg]*

    *Weightisperunitnotincludingsub-basemanifold.

    MECHANICALPressureRanges29.9in.Hg(VAC)-175psig(12barg)**[760mmHg(VAC)-1207kPa]OutputPressure0-100%ofrangeFlowRate

    Standard1.2SCFM@100psig(6.9barg)inlet[[email protected]]HighFlow(S938)3.5SCFM@100psig(6.9barg)inlet[[email protected]]

    CvCapacityStandard0.04HighFlow(S938)0.13

    Min.ClosedEndVolume1in3FiltrationRecommended40micronminimal LinearityHysteresis+-0.2%F.S.BFSL(Adjustable) Repeatability+/-0.02F.S.Accuracy+/-0.2%F.S.TemperatureEffect+/-25C=+/-0.7%FSWettedPartsElastomers-Fluorocarbon;Manifold-BrassValves-Polyamide,AluminaCeramic,Epoxy,Silicon,GlassandSolderPortSizes1/8inch**Pressurerangesarecustomerspecified.***Othermanifoldmaterialsareavailable.ConsultFactory.

  • PROPORTION-AIR 317-335-2602

    MaxINPressure:200psig(20.6bar)MaxOUTPressure:175psig(12bar)TypicalAccuracy:+/-0.2%(FullScaleofsensor) Regulators:nonePowerSupply:15VDC,24VDC,12VDC(OptionP1)

    MM SERIES ORDERING INFORMATION

    1=OpenLoop2=ClosedLoop B=Brass

    D=DINRailMount(PortsonFace)M=ManifoldMount(PortsonBottom)P =PanelMount(PortsonFace)

    H=ManifoldMount(NoThreads) N=NPTP=BSPP(Non-Standard)

    MMSeries

    EMonitorSignalRange

    2Type

    BManifoldMaterial

    DMountType

    NThreadType

    EInputSignalRange

    N= 0% Pressure Starts Below AtmosphereP=0% Pressure Starts Above AtmosphereZ=0% Pressure Starts at ZeroE=0to10VDC

    I =4to20mADC K=0to5VDC V=1to5VDC

    X=NoMonitorSignalC=4to20mADCSinkingE=0to10VDCK=0to5VDC1S=4to20mADCSourcingV=1to5VDC11OnlyavailableifthesameInputSignalRangeisselected

    MM SERIES ACCESSORIESPower Connector

    H14612

    Mounting Kits

    DINRail DRMKT-01PanelMount PMK-MMManifoldMount SeeHARDWAREKIT

    Station Plug

    H316

    MM SERIES SUB BASE MANIFOLD

  • 317-335-2602 PROPORTION-AIR

    14.7=Startingat14.71,2,3,41Example2Maximum10%ofFullScalePressureifZeroOffsetisPressureType3LeftblankifZeroOffsetZ4PressureAvailableuptohundrethofaunit

    N=0%PressureStartsBelowAtmosphereP=0%PressureStartsAboveAtmosphereZ=0%PressureStartsatZero

    X = No Monitor SignalC = 4 to 20 mADC

    Sinking

    E = 0 to 10 VDCK = 0 to 5 VDC1S = 4 to 20 mADC

    Sourcing

    V = 1 to 5 VDC11Only available if the same InputSignal Range is selected

    DYNAMICLISTDR=InstallDINRailMountingKit DV=DifferentialVoltageInputFA=FailToAtmosphereHE=HighFlowExhaustValveHI =HighFlowInletValveHQ=HighFlowInlet&ExhaustValvesNC=NoMatingConnectorShippedwithUnitP1=12VDCPower*Consultthefactoryifmorethan4optionsrequired

    A=AbsolutePressure*G=GagePressure*MustbeAifPressureUnitofMeasureTypeisTR

    PS =psiMB =mbarBR =barKP =kPaMP =MPaMH =mmHgIH =in.HgIW =in.H2OMW=mmH2OKG =kg/cmTR =TorrCW=cmH2O

    120.55=Endingat120.551,2,31Example2175psig(12barg)Maximum3Pressureavailableuptohundredthofaunit

    N=100%PressureEndsBelowAtmosphereP=100%PressureEndsAboveAtmosphereZ=100%PressureEndsatZero

    5ZeroOffset

    Pressure

    NZeroOffsetPressureType

    APressureTypeUOM

    00Option

    MBPressureUnit

    120.55FullScalePress

    PFullScalePressureType

    MM SERIES SUB BASE MANIFOLDSBM-Series

    2NumberofStations

    2Stations3Stations4Stations5Stations6Stations7Stations8Stations9Stations10Stations11Stations12Stations

    HK-Series

    2NumberofStations

    2Stations3Stations4Stations5Stations6Stations7Stations8Stations9Stations10Stations11Stations12Stations

  • Proportion-Airproductsarewarrantedtotheoriginalpurchaseronlyagainstdefectsinmaterialorworkmanshipforone(1)yearfromthedateofmanufacture.TheextentofProportion-Air'sliabilityunderthiswarrantyislimitedtorepairorreplacementofthedefectiveunitatProportion-Air'soption.Proportion-Airshallhavenoliabilityunderthiswarrantywhereimproperinstallationorfiltrationoccurred.

    Allspecificationsaresubjecttochangewithoutnotice.THISWARRANTYISGIVENINLIEUOF,ANDBUYERHEREBYEXPRESSLYWAIVES,WARRANTIESORLIABILITIES,EXPRESS,IMPLIEDORSTATUTORY,INCLUDINGWITHOUTLIMITATIONANYOBLIGATIONOFPROPORTION-AIRWITHREGARDTOCONSEQUENTIALDAMAGES,WARRANTIESOFMERCHANTABILITY,DESCRIPTION,ANDFITNESSFORAPARTICULARPURPOSE.

    .............................................................................................................................................................................................................................................................WARNING:Installationanduseofthisproductshouldbeunderthesupervisionandcontrolofproperlyqualifiedpersonnelinordertoavoidtheriskofinjuryordeath.

    CATALOGNO.BRMM0113

    PROPORTION-AIR, INC. 8250 N. 600 West, P.O. Box 218 McCordsville, Indiana USA 46055

    Phone 317-335-2602 Fax 317-335-3853www.proportionair.com [email protected]

    ONE PRODUCT THOUSANDS OF WAYS

    Proportion-Airofferyouthetechnicalknowledge,expertiesandcapabilitiesthathavedevelopedconceptsintotheformostcontrolproductsinoperationaroundtheworld.