product catalogue hydrostatic probes screw-in … · product catalogue hydrostatic probes screw-in...

116
PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

Upload: others

Post on 11-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

PRODUCT CATALOGUE

HYDROSTATIC PROBES

SCREW-IN TRANSMITTERS

Page 2: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

2

PRESSURE

AT THE

HIGHEST LEVEL

„Successful medium-sized

companies are not successful

because they are active in many

areas, but rather because they

concentrate on one area and do it

better than anyone else“

This is our philosophy. That´s why BD|SENSORS has

concentrated on electronic pressure measurement

technology from the beginning.

With our unremitting product and and quality stra-

tegy we have been successful in becoming a major

player on the world market for electronic pressure

sensing devices within a few years.

Page 3: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

INDEX

PROBES 5-88

PRECISION: STAINLESS STEEL PROBES

stainless steel sensor 5-20

ceramic sensor 21-24

INDUSTRY: STAINLESS STEEL PROBES

stainless steel sensor 25-40

ceramic sensor 41-68

INDUSTRY: PLASTIC PROBES

stainless steel sensor 69-72

ceramic sensor 73-88

SCREW-IN TRANSMITTERS 89-100

stainless steel sensor 89-92

ceramic sensor 93-100

SPECIAL VERSIONS 101-104

ACCESSORIES 105-113

4 ARGUMENTS 114

With 260 employees at 4 locations in Germany, the Czech

Republic, Russia and China BD|SENSORS has solutions

from 0.1 mbar to 6000 bar:

> pressure sensors, pressure transducers pressure transmitters

> electronic pressure switches

> pressure measuring devices with display and switching outputs

> hydrostatic level probes

Two pressure transmitters and a submersible probe, based

on a stainless steel silicon sensor were the beginning.

Today the range extends to more than 70 standard pro-

ducts, from economical OEM devices to high-end products

with HART® communication or field bus interface.

In addition we have developed hundreds of customer-

specific applications, underlining the competence and fle-

xibility of BD|SENSORS. The excellent price/performance

ratio of our products is proof of the fact that we are able to

meet the toughest demand: Being a problem-solver for our

customers.

For large production batches as well as for small pro-duction numbers, no matter for what medium or external factors, with almost any mechanical or electrical connec-tion - we solve your problem

flexibly, quickly and cost-efficiently.

Page 4: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

4 MATRIX

housing material

preferred areas of usecable-sensor

stai

nles

s st

eel

plas

tic

CuN

iFe

ø [m

m]

stai

nles

s st

eel s

enso

r

cera

mic

sen

sor

pres

sure

ran

ge /

le

vel [

mH

2O]

wat

er

sew

age

fuel

and

oil

aggr

essi

ve m

edia

not s

epar

able

sepa

rabl

e

cert

ifica

tes

page

precision

LMP 307i • 26.5 • 0 … 0.4 up to 0 … 200 • EX 5-8

LMP 308i • 35 • 0 … 4 up to 0 … 200 • EX 9-12

LMK 382H • 39.5 • 0 … 0.6 up to 0 … 100 • EX, HART® 13-16

LMK 458H • • 39.5 • 0 … 0.6 up to 0 … 200 •EX, HART®, DNV, GL, CCS

17-20

LMK 358H • 39.5 • 0 … 0.6 up to 0 … 100 • EX, HART® 21-24

industry

LMP 305 • 19 • 0 … 1 up to 0 … 250 • 25-28

LMP 307 • 27 • 0 … 1 up to 0 … 250 • EX, SIL 29-32

LMP 307T • 27 • 0 … 1 up to 0 … 250 • 33-36

LMP 308 • 35 • 0 … 1 up to 0 … 250 • EX, SIL 37-40

LMK 306 • 17 • 0 … 6 up to 0 … 200 • 41-44

LMK 307 • 27 • 0 … 4 up to 0 … 250 • EX, SIL 45-48

LMK 307T • 26,5 • 0 … 4 up to 0 … 250 • 49-52

LMK 382 • 39.5 • 0 … 0.4 up to 0 … 100 • EX 53-56

LMK 387 • 22 • 0 … 1 up to 0 … 100 • EX 57-60

LMK 458 • • 39.5 • 0 … 0.4 up to 0 … 200 •EX, DNV, GL, CCS

61-64

LMK 358 • 39.5 • 0 … 0.4 up to 0 … 100 • EX 65-68

LMP 808 • 35 • 0 … 1 up to 0 … 100 • SIL 69-72

LMK 806 • 21 • 0 … 6 up to 0 … 200 • 73-76

LMK 807 • 35 • 0 … 4 up to 0 … 100 • SIL 77-80

LMK 809 • 45 • 0 … 0.4 up to 0 … 100 • 81-84

LMK 858 • 45 • 0 … 0.4 up to 0 … 100 • 85-88

screw-in transmitter

LMP 331 • • 0 … 1 up to 0 … 400 EX, SIL, UL 89-92

LMK 331 • • • 0 … 4 up to 0 … 600 EX, SIL, UL 93-96

LMK 351 • • • 0 … 0.4 up to 0 … 200 EX,UL 97-100

special versions

EP 500 • • 0 … 60 mbar up to 0 … 20 bar GL, CCS 101-104

www.bdsensors.com

Page 5: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

5

BD SENSORS GmbH BD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com D - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 307i

Stainless Steel Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.1 % FSO

Nominal pressure

from 0 ... 0.4 mH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mA 3-wire: 0 ... 10 V others on request

Special characteristics

diameter 26.5 mm small thermal effect excellent accuracy excellent long term stability

Optional versions

IS-protection zone 0 cable protection via corrugated pipe different kinds of cables

different kinds of seal materials

The stainless steel probe LMP 307i is designed for continuous level measurement in water and clean or waste fluids.

Basic element is a high quality stainless steel sen-sor with high requirements for exact measurement with excellent long term stability.

Preferred areas of use are

Water / filtrated sewagedrinking water system ground water level measurement rain spillway basin pump and booster stations level measurement in container water treatment plants water recycling

Fuel / Oilfuel storage tank farm

PROBES

www.bdsensors.com

Page 6: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

6

LMP 307i Stainless Steel Probe Technical Data

pressure and level

Input pressure range1

Nominal pressure gauge [bar] 0.40 1 2 4 10 20 Level [mH2O] 4 10 20 40 100 200 Overpressure [bar] 2 5 10 20 40 80 Burst pressure [bar] 3 7.5 15 25 50 120 1 On customer request we adjust the device within the turn-down-possibility by software on the required pressure range. Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC Option Ex-protection 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC Options 3-wire 3-wire: 0 ... 10 V / VS = 14 ... 36 VDC PerformanceAccuracy nominal pressure ≥ 0.1 bar: ≤ ± 0.1 % FSO

nominal pressure < 0.1 bar: ≤ ± 0.2 % FSO Permissible load Rmax = [(VS – VS min) / 0.02 A] Ω Influence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩ Long term stability ≤ ± 0.1 % FSO / year at reference conditions 1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (Offset and Span)Tolerance band [% FSO] ≤ ± 0.2 in compensated range -20 … 80°C TC [% FSO / 10K] ≤ ± 0.02 in compensated range -20 … 80°C Permissible temperaturesPermissible temperatures medium: -10 ... 70 °C storage: -25 ... 70 °C Electrical protection 2

Insulation resistance > 100 MΩ Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 61326 2 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Electrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) black FEP4 (-10 … 70 °C) black

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)

Seals FKM others on request

Diaphragm stainless steel 1.4435 (316L) Protection cap POM Explosion protection (only for 4 ... 20 mA / 2-wire)Approvals DX19-LMP 307i

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Ga zone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 nF, Li ≈ 0 µH, the supply connections have an inner capacity of max. 27 nF to the housing

Ambient temperature range in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 bar in zone 1 or higher: -20 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/m cable inductance: signal line/shield also signal line/signal line: 1µH/m

MiscellaneousCurrent consumption max. 25 mA Weight approx. 200 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 2004/108/EC ATEX Directive 94/9/EG

LMP 307iTechnical Data

www.bdsensors.com

Page 7: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

7

LMP 307i Stainless Steel Probe Technical Data

pressure and level

Mounting flange with cable glandTechnical dataSuitable for all probes Flange material stainless steel 1.4404 (316L) Material of cable gland standard: brass, nickel plated

on request: stainless steel 1.4305 (303); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 2507 Version Size (in mm) WeightDN25 / PN40 D = 115, k = 85, b = 18, n = 4, d= 14 1.4 kg DN50 / PN40 D = 165, k = 125, b = 20, n = 4, d= 18 3.2 kg DN80 / PN16 D = 200, k = 160, b = 20, n = 8, d= 18 4.8 kg Ordering type Ordering code DN25 / PN40 with cable gland brass, nickel plated ZMF2540 DN50 / PN40 with cable gland brass, nickel plated ZMF5040 DN80 / PN16 with cable gland brass, nickel plated ZMF8016 Terminal clampTechnical dataSuitable for all probes with cable ∅ 5.5 ... 10.5 mm Material standard: steel, zinc plated

optionally: stainless steel 1.4301 (304) Weight approx. 160 g Ordering type Ordering code Terminal clamp, steel, zinc plated Z100528 Terminal clamp, stainless steel 1.4301 (304) Z100527 Display program

CIT 200Process display with LED display CIT 250Process display with LED display and contacts CIT 300Process display with LED display, contacts and analogue output CIT 350Process display with LED display, bargraph, contacts and analogue output CIT 400Process display with LED display, contacts, analogue output and Ex-approval CIT 600Multichannel process display with graphics-capable LC display CIT 650Multichannel process display with graphics-capable LC display and datalogger CIT 700 / CIT 750Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440Field display with 4-digit LC display

For further information please contact our sales department or visit our homepage: http://www.bdsensors.com

Accessories

cable gland M16x1.5 with seal insert (for cable-∅ 4 ... 11 mm)

LMP307i_E_081215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

©20

15BD

|SEN

SOR

S G

mbH

–Th

e sp

ecifi

catio

ns g

iven

in th

is d

ocum

ent r

epre

sent

the

stat

e of

eng

inee

ring

at th

e tim

e of

pub

lishi

ng. W

e re

serv

e th

e rig

ht to

mak

e m

odifi

catio

ns to

the

spec

ifica

tions

and

mat

eria

ls.

LMP 307iTechnical Data

www.bdsensors.com

Page 8: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

8

www.bdsensors.com

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

- - - - - - - - - -Pressure

4 5 04 5 1

Input [mH2O] [bar]4.0 0.40 4 0 0 010 1.0 1 0 0 125 2 2 0 0 140 4.0 4 0 0 1100 10 1 0 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output1E39 consult

Seals19 consult

Accuracystandard for PN ≥ 0.1 bar 0.1 % 1standard for PN < 0.1 bar 0.2 % B

9 consultElectrical connection

1239 consult

Cable lengthin m

Special version1 1 1

9 9 9 consult

9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

08.12.2015 © 2

015

BD

|SE

NS

OR

S G

mbH

– T

he s

peci

ficat

ions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

g at

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

FKM

Ordering code LMP 307i

LMP 307i

in mH2O

Stainless steel 1.4404 (316L)

stainless steel corrugated pipe

PUR-cable

customer

Stainless steel 1.4435 (316L)

0 … 10 V / 3-wirecustomer

customer

PVC-cable

standard

in bar

customer

cable protection with

4 … 20 mA / 2-wire

1

1

customer

customer

intrinsic safety 4 … 20 mA / 2 wire

customer

3

FEP-cable

with pipe length in m

1

01

customer

LMP 307iOrdering code

Page 9: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

9

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 308iSeparable Stainless Steel Probe Precision

Stainless Steel Sensor

accuracy according to IEC 60770: 0.1 % FSO

Nominal pressure

from 0 ... 4 mH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 10 Vothers on request

Special characteristics

diameter 35 mm cable and sensor section separable

excellent accuracy

communication connection

thermal error in compensated range-20 ... 70 °C: 0.2 % FSOTC 0.02 % FSO / 10K

Turn-Down 1:10

Optional versions

IS-version zone 0 cable protection via corrugated pipe mounting accessories as cable gland

and terminal clamp in stainless steel different kinds of cables different kinds of seal materials

The separable precision stainless steel probe LMP 308i is designed for continuous fill level and level measurement of water and liquid mediums.The signal processing of sensor signal is done by digital electronics with 16-bit analog digital conver-ter. Consequently it is possible to conduct an ac-tive compensation of sensor intrinsic deviations from normal condions like nonlinearity and thermal error.

In order to facilitate stock-keeping and mainten-ance the transmitter body is plugged to the cable assembly with a connector and can be changed easily.

Preferred areas of use are

Water / filtrated Sewageground water level measurementlevel measurement in wells and open waters / rain spillway basinlevel measurement in containerwater treatment plantswater recycling

PROBES

www.bdsensors.com

Page 10: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

10

LMP 308iPrecision Stainless Steel Probe Technical Data

pressure and level

Input pressure range 1

Nominal pressure gauge [bar] 0.40 1 2 4 10 20Level [mH2O] 4 10 20 40 100 200Overpressure [bar] 2 5 10 20 40 80Burst pressure [bar] 3 7.5 15 25 50 1201 On customer request we adjust the device within the turn-down-possibility by software on the required pressure range.Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC with RS-232 communication interfaceOption IS-protection 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC

Options 3-wire: 0 ... 10 V / VS = 14 ... 36 VDC

PerformanceAccuracyPerformance after turn-down (TD)- TD ≤ 1:5- TD > 1:5

IEC 60770 2: ≤ ± 0.1 % FSO

no change of accuracy 3formula for accuracy calculating (for nominal pressure gauge ≤ 0.40 bar see note 3):≤ ± [0.1 + 0.015 x turn-down] % FSOwith turn-down = nominal pressure range / adjusted rangee.g. follwing accuracy can be calculated for turn-down 1:10:≤ ± (0.1 + 0.015 x 10) % FSO viz. the accuracy is ≤ ± 0.25 % FSO

Permissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ωvoltage 3-wire: Rmin = 10 kΩ

Influence effects supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩLong term stability ≤ ± (0.1 x turn-down) % FSO / year at reference conditionsResponse time ca. 200 msec

Adjustabilityfollowing parameters can be adjusted (interface / software needed 4)electronic damping: 0 ... 100 secoffset: 0 ... 90 % FSO turn-down of span: max. 1:10

2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 nominal pressure gauges ≤ 0,40 bar are excluded; for these the calculation of accuracy is as follows:≤ ± (0.1 + 0.02 x turn-down) % FSO e.g. torn-down 1:3: ≤ ± (0.1 + 0.02 x 3 ) % FSO viz. the accuracy is ≤ ± 0.16 % FSO4 software, interface and cable must separate be ordered (software is compatible with Windows® 95, 98, 2000, NT from version 4.0 or higher and XP)Thermal effects (Offset and Span)Tolerance band [% FSO] ≤ ± (0.2 x turn-down) in compensated range -20 ... 70 °CTC [% FSO / 10 K] ± (0.2 x turn-down) in compensated range -20 ... 70 °CPermissible temperatures medium: -20 ... 70 °C storage: -25 ... 70 °C electronics / enviroment: -25 ... 65 °CElectrical protection 5

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613265 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 6 PVC (-5 … 70 °C) grey

PUR (-20 … 70 °C) blackFEP7 (-20 … 70 °C) black others on request

6 cable with integrated air tube for atmospheric pressure reference7 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM, EPDM, others on requestDiaphragm stainless steel 1.4435 (316L)Protection cap POMExplosion protection (only for 4 ... 20 mA / 2-wire)ApprovalsDX19-LMP 308 i

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 nF, Li ≈ 0 µH,the supply connections have an inner capacity of max. 27 nF to the housing

Ambient temperature range in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barin zone 1 or higher: -20 ... 65 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance:signal line/shield also signal line/signal line: 1µH/m

MiscellaneousCurrent consumption signal output current: max. 25 mA Weight approx. 250 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC

LMP 308iTechnical Data

www.bdsensors.com

Page 11: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

11

LMP 308iPrecision Stainless Steel Probe Technical Data

www.bdsensors.com

ATEX Directive 94/9/EGWiring diagram / connector

2-wire-system (current) 3-wire-system (voltage) Binder series 723 8 (5-pin)

Binder series 723 8 (7-pin)

Pin configuration

Electrical connection Binder series 723 8 (5-pin) / 2-wire

Binder series 723 8 (5-pin) / 3-wire

Binder series 723 8 (7-pin) / 2-wire

with communication interface

cable colours(DIN 47100)

Supply + Supply –

Signal + (for 3-wire) RxD TxD

GND

3 1 - - - -

3 4 1 - - -

3 / wh (white) 1 / bn (brown) (6) / gn (green) 4 / ye (yellow) 5 / gr (gray)

7 / gn (green)

wh (white) bn (brown) gn (green)

- - -

Shield 5 5 2 / gn/ye (green / yellow) gn/ye (green / yellow)8 in separated versionDimensions (in mm)

standard option

separated version version withcorrugated pipe

Supply +

Signal +

VS

V

p

U

Supply –

p supply +

supply –

VS

I

LMP 308iTechnical Data

www.bdsensors.com

Page 12: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

12

www.bdsensors.com

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

- - - - - - - - - -Pressure

4 4 04 4 1

Input [mH2O] [bar]4.0 0.40 4 0 0 010 1.0 1 0 0 120 2.0 2 0 0 140 4.0 4 0 0 1100 10 1 0 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output1E39 consult

Seals139 consult

Electrical connection1239 consult

Accuracy0.1 % 1

9 consultCable length

in m 9 9 9 consultVersion

1 1 11 2 1

9 9 9 consult

9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 available on request: calibration of individual pressure range higher than 400 mbar with accuracy 0.1 %3 Software, interface and cable have to be order separately (Ordering code: CIS-G; Software appropriate for Windows® 95, 98, 2000, NT Version 4.0 or newer and XP)4 stainless steel pipe is not part of the supply

Windows® is a registrated trademark of Microsoft Corporation

01.06.2013

prepared for mounting

1

1

1

2

3

4

PUR-cable

customer

standard

1 2 6

with communicaton interface

cable protection with stainless steel corrugated pipe

with pipe length in m1 2 3

Stainless steel 1.4435 (316L)

Ordering code LMP 308i

customer

with stainless steel pipe

FKM

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

Intrinsic safety 4 … 20 mA / 2-wire

EPDM

customer

PVC-cable

customer

FEP-cable

customer

4 … 20 mA / 2-wire

0 … 10 V / 3-wire

customer

in mH2Oin bar

customer

LMP 308i

consult

customer

Stainless steel 1.4404 (316L)

LMP 308iOrdering code

Page 13: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

13

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 382H

Stainless Steel Probewith HART®-communication

Ceramic Sensor

accuracy according to IEC 60770:0.1 % FSO

Nominal pressure

from 0 ... 60 cmH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 39.5 mm HART® communication (setting of

offset, span and damping) permissible temperatures up to 85 °C high overpressure resistance high long-term stability

Optional versions

IS-version zone 0 mounting with stainless steel pipe flange version diaphragm 99.9 % AI2O3

accessories e.g. assembling and probe flange, mounting clamp

The stainless steel probe LMK 382H has been designed for continous level measurement in waste water, waste and higher viscosity medi-ums.

Basic element is a robust and high overpressure capable capacitive ceramic sensor e.g. for low levels.

Preferred areas of use are

Waterground water level measurementrain spillway basin

Sewagewaste water treatmentwater recycling

Fuel / Oillevel monitoring in open tankswith low filling heightsfuel storagetank farmsbiogas plants

Page 14: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

14

LMK 382HStainless Steel Probe Technical Data

pressure and level

Pressure ranges 1

Nominal pressure [bar] 0.06 0.16 0.4 1 2 5 10 20Level [mH2O] 0.6 1.6 4 10 20 50 100 200Overpressure [bar] 2 4 6 8 15 25 35 451 On customer request we adjust the devices by software on the required pressure ranges, within the turn-down possibility (starting at 0.02 bar).

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC with HART® communication VS rated = 24 VDC

Option IS- protection 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC with HART® communication VS rated = 24 VDC

PerformanceAccuracy 2 PN ≥ 160 mbar TD ≤ 1:5 ≤ ± 0.2 % FSO

TD > 1:5 ≤ ± [0.2 + 0.03 x TD] % FSO TDmax = 1:10

PN < 160 mbar ≤ ± [0.2 + 0.1 x TD] % FSO TDmax = 1:3PN ≥ 1 bar TD ≤ 1:5 ≤ ± 0.1 % FSO

TD > 1:5 ≤ ± [0.1 + 0.02 x TD] % FSOTDmax = 1:10

Permissible load Rmax = [(VS - VS min) / 0.02 A] Ω load at HART-communication: Rmin = 250 ΩLong term stability ≤ ± (0.1 x turn-down) % FSO / year at reference conditionsInfluence effects supply: 0.05 % FSO / 10 V permissible load: 0.05 % FSO / kΩTurn-on time 850 msecMean response time 140 msec without consideration of electronic damping mean measuring rate 7/secMax. response time 380 msecAdjustability configuration of following parameters possible (interface / software necessary 3):

- electronic damping: 0 ... 100 sec- offset: 0 ... 80 % FSO- turn down of span: max. 1:10

2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 software, interface, and cable have to be ordered separately (software appropriate for Windows® 95, 98, 2000, NT Version 4.0 or higher, and XP)Thermal effects (Offset and Span)Tolerance band ≤ ± (0.2 x turn-down) % FSOTC, average ± (0.02 x turn-down) % FSO / 10 Kin compensated range -20 ... 80 °CPermissible temperatures medium: -25 … 85 °C

electronics / environment: -25 … 85 °C storage: -25 … 85 °C

Electrical protection 4

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613264 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestMechanical stabilityVibration 4 g (according to: DIN EN 60068-2-6)Electrical connectionCable outlet with sheat material5 PVC (-5 … 70 °C) grey

PUR (-25 … 70 °C) black FEP6 (-25 … 70 °C) blackTPE (-25 … 85 °C) blue

5 shielded cable with integrated air tube for atmospheric pressure reference6 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterialsHousing stainless steel 1.4404Seals FKM

FFKMEPDMothers on request

Diaphragm standard: ceramics Al2O3 96 %option: ceramics Al2O3 99.9 %

Protection cap POMMiscellaneousOption cable protection stainless steel pipe for probe in stainless steel: available as compact product (standard: stainless

steel pipe with a total length up to 2 m possible; other lengths on request)Ingress protection IP 68Current consumption max. 21 mAWeight approx. 400 g (without cable)CE-conformity EMC Directive: 2004/108/EC

LMK 382 HTechnical Data

www.bdsensors.com

Page 15: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

15

LMK 382HStainless Steel Probe Technical Data

www.bdsensors.com

IS-protectionApproval DX15A-LMK 382H IBExU 10 ATEX 1186 X

zone 0 7: II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T85 °C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 13,2 nF, Li = 0 µH,the supply connections have an inner capacity of max. 27 nF opposite the enclosure

Permissible media temperature in zone 0: -10 ... 60 °C with patm 0.8 bar up to 1.1 bar zone 1 or higher: -25 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

7 for optional stainless steel pipe following designation is valid: "II 1G Ex ia IIC T4" (zone 0)Wiring diagram2-wire-system (current) HART®

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

wh (white)bn (brown)

Shield gnye (green-yellow)Dimensions (in mm)

dimensions in mmdimen-sions

DN25 /PN40

DN40/PN40

DN50 /PN40

DN80 /PN16

D 115 150 165 200K 85 110 125 160d4 68 88 102 138b 18 18 20 20f 2 3 3 3n 4 4 4 8

d2 14 18 18 18

HART® is a registered trade mark of HART Communication Foundation;Windows® is a registered trade mark of Microsoft Corporation

flange versionthread R1"for stainless steel pipestandard

psupply +

supply –

VS

I

LMK 382 HTechnical Data

www.bdsensors.com

Page 16: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

16

www.bdsensors.com

- - - - - - - - -Pressure

5 6 55 6 6

Input [mH2O] [bar]0.60 0.06 0 6 0 01.60 0.16 1 6 0 04.00 0.40 4 0 0 010 1.0 1 0 0 120 2.0 2 0 0 150 5.0 5 0 0 1

100 10 1 0 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm2C9 consult

Output

9 consultSeals

13

FFKM 79 consult

Electrical connection123

TPE-cable 1 49 consult

AccuracyPN ≥ 1 bar 0.1 % 1PN < 1 bar 0,2 % B

9 consultCable length

in m 9 9 9Special version

0 0 0

5 1 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 stainless steel pipe is not part of the supply

HART® is a registered trade mark of HART Communication Foundation

13.01.2016

1

1

1

2

customer

HART®-communication

Ordering code LMK 382H

Stainless steel 1.4404 (316L)

in bar

customer

LMK 382H

in mH2O

PUR-cable

HART®-communication

customer

customer

© 2

016

BD

|SE

NS

OR

S G

mbH

– T

he s

peci

ficat

ions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

g at

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

Ceramics Al2O3 99.9%

EPDM

Ceramics Al2O3 96%

customer

prepared for mounting

flange versionwith stainless steel pipe

4 … 20 mA / 2-wire

Intrinsic safety 4 … 20 mA / 2-wire

FKM

H

I

customer

customer

PVC-cable

customer

2

FEP-cable

5 0

standard

LMK 382 HOrdering code

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 17: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

17

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 458HProbewith HART®-communicationfor Marine and Offshore

Ceramic Sensor

accuracy according to IEC 60770:0.1 % FSO

Nominal pressure

from 0 ... 60 cmH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

shipping approvals acc. to:Lloyd´s Register (LR), Germanischer Lloyd (GL), Det Norske Veritas (DNV)China Classification Society (CCS),American Bureau of Shipping (ABS)

diameter 39.5 mm HART® communication (setting of

offset, span and damping) high overpressure resistance high long-term stability

Optional versions

IS-version zone 0 diaphragm AI2O3 99.9 % different housing materials

(stainless steel, CuNiFe) screw-in and flange version accessories e. g. assembling and

probe flange, mounting clamp

The hydrostatic probe LMK 458H has been de-veloped for measuring level in service and stor-age tanks and is as a consequence certificatedfor shipbuilding and offshore applications.

A permissible operating temperature of up to 85°C and the possibility to use the device in in-trinsic safe areas enable to measure the pres-sure of various fluids under extreme conditions. The basis for the LMK 458H is a capacitive ce-ramic sensor element, which offers a high over-load resistance and medium compatibility.

Preferred areas of use are

WaterDrinking water abstractionDesalinization plant

Shipbuilding / OffshoreBallast tanksDraught monitoringLevel measurement in ballast and storage tanks

Page 18: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

18

LMK 458HHydrostatic Probe Technical Data

pressure and level

Pressure rangesNominal pressure 1 [bar] 0.06 0.16 0.4 1 2 5 10 20Level [mH2O] 0.6 1.6 4 10 20 50 100 200Overpressure [bar] 2 4 6 8 15 25 35 451 On customer request we adjust the devices by software on the required pressure ranges, within the turn-down possibility (starting at 0.02 bar).Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC with HART communication VS rated = 24 VDC

Option IS-version 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC with HART communication VS rated = 24 VDC

PerformanceAccuracy 2 PN ≥ 160 mbar TD ≤ 1:5 ≤ ± 0.2 % FSO

TD > 1:5 ≤ ± [0.2 + 0.03 x TD] % FSO TDmax = 1:10

PN < 160 mbar ≤ ± [0.2 + 0.1 x TD] % FSO TDmax = 1:3

PN ≥ 1 bar TD ≤ 1:5 ≤ ± 0.1 % FSOTD > 1:5 ≤ ± [0.1 + 0.02 x TD] % FSO TDmax = 1: 10

Permissible load Rmax = [(VS - VS min) / 0.02 A] Ω load at HART-communication: Rmin = 250 ΩLong term stability ≤ ± (0.1 x turn-down) FSO / year at reference conditionsInfluence effects supply: 0.05 % FSO / 10 V permissible load: 0.05 % FSO / kΩTurn-on time 850 msecMean response time 140 msec without consideration of electronic damping mean measuring rate 7/secMax. response time 380 msecAdjustability configuration of following parameters possible (interface / software necessary 3):

- electronic damping: 0 ... 100 sec- offset: 0 ... 80 % FSO- turn down of span: max. 1:10

2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 software, interface, and cable have to be ordered separately (software appropriate for Windows® 95, 98, 2000, NT Version 4.0 or higher, and XP)

Thermal effects (Offset and Span) / Permissible temperaturesTolerance band ≤ ± [0.2 x turn-down] % FSOTC, average ≤ ± [0.02 x turn-down] % FSO / 10 Kin compensated range -20 … 80 °CPermissible temperatures medium: -25 … 85 °C electronics / environment: -25 … 85 °C storage: -25 … 85 °CElectrical protection 4

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to

- EN 61326 - Germanischer Lloyd (GL) - Det Norske Veritas (DNV)4 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference availableMechanical stabilityVibration 4 g (according to GL: curve 2 / according to DNV: Class B / basis: DIN EN 60068-2-6)Electrical connectionCable shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges abso-

lute, the air tube is closed)Materials (media wetted)Housing standard: stainless steel 1.4404 (316L)

option: CuNi10Fe1Mn (resistant against sea water) others on requestCable sheath TPE -U (flame-resistant, halogen free, increased resistance against oil and gasoline,

resistant against salt, sea water, heavy oil)Seals FKM; FFKM; EPDM

others on requestDiaphragm standard: ceramics Al2O3 96 %

option: ceramics Al2O3 99.9 % Nose cone POMMiscellaneousCable protection stainless steel pipe for probe in stainless steel: available as compact product (standard: stainless

steel pipe with a total length up to 2 m possible; other lengths on request)Ingress protection IP 68Current consumption max. 21 mAWeight min. 650 g (without cable)CE-conformity EMC Directive: 2004/108/ECCategory of the environmentLloyd´s Register (LR) EMV1, EMV2, EMV3, EMV4 number of certificate: 13/20056Germanischer Lloyd (GL) D, EMC 1 number of certificate: 19 777 - 11 HHDet Norske Veritas (DNV) temperature: D humidity: B vibration: B

electromagnetic compatibility: B number of certificate: A-12144

LMK 458 HTechnical Data

www.bdsensors.com

Page 19: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

19

LMK 458HHydrostatic Probe Technical Data

www.bdsensors.com

IS-protectionApproval DX15A-LMK 458H IBExU 10 ATEX 1186 X

zone 0 5: II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T85 °C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 94,6 nF; Li = 0 µH;the supply connections have an inner capacity of max. 110 nF opposite the enclosure

Permissible temperatures for environment in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 bar zone 1 and higher: -25 ... 70 °C

Connecting cables (by factory)

cable capacity: signal line/shield as well as signal line/signal line: 160 pF/mcable inductance: signal line/shield as well as signal line/signal line: 1 µH/m

5 for optional stainless steel pipe the following designation is valid: "II 1G Ex ia IIC T4" (zone 0)Wiring diagrams Pin configuration2-wire-system (current) HART®

Electrical connection cable colours (IEC 60575)

Supply VS+Supply VS–

wh (white)bn (brown)

Shield gnye (green-yellow)

Dimensions (in mm)

probe version

stainless steel / CuNiFe prepared for mountingwith stainless steel pipe

HART® is a registered trade mark of HART Communication Foundation;Windows® is a registered trade mark of Microsoft Corporation

Dimensions (in mm)

screw-in version flange version

stainless steel / CuNiFe stainless steel / CuNiFe

psupply +

supply –

VS

I

LMK 458 HTechnical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 20: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

20

www.bdsensors.com

- - - - - - - - - -Pressure

7 6 E7 6 G consult7 6 H7 6 F

Input [mH2O] [bar]0.60 0.06 0 6 0 01.60 0.16 1 6 0 04.00 0.40 4 0 0 010 1.0 1 0 0 120 2.0 2 0 0 150 5.0 5 0 0 1100 10 1 0 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

1K9 consult

Design135

Diaphragm2C9 consult

Output

H

I

9 consultSeals

13

FFKM 79 consult

Electrical connection49

AccuracyPN ≥ 1 bar 0.1 % 1PN < 1 bar 0,2 % B

9 consultCable length

9 9 9Special version

0 0 05 0 29 9 9 consult

1 nominal pressure ranges sealed gauge and absolute from 1 bar2 mounting accessories are not part of supply and have to be ordered separately3 shielded cable with integrated air tube for atmospheric reference4 stainless steel pipe is not part of the supply

HART® is a registered trade mark of HART Communication Foundation

13.01.2016 © 2

016

BD|S

ENSO

RS

Gm

bH –

The

spe

cific

atio

ns g

iven

in th

is d

ocum

ent r

epre

sent

the

stat

e of

eng

inee

ring

at th

e tim

e of

pub

lishi

ng. W

e re

serv

e th

e rig

ht to

mak

e m

odifi

catio

ns to

the

spec

ifica

tions

and

mat

eria

ls.

Ordering code LMK 458H

LMK 458H

in bar, gauge in bar, sealed gauge 1

in bar, absolute 1

in mH2O

customer

Stainless steel 1.4404 (316L)Copper-Nickel-alloy (CuNi10Fe1Mn)

customer

Submersible transmitter 2

HART®-communicationIntrinsic safety 4 … 20 mA / 2-wire

customer

Flange transmitter 2

Screw-in transmitter 2

customer

FKM

Ceramics Al2O3 96%Ceramics Al2O3 99.9%

HART®-communication4 … 20 mA / 2-wire

customer

customer

customer

EPDM

standardprepared for mounting with st. steel pipe

3

2, 4

TPE-U-cablecustomer

in m

LMK 458 HOrdering code

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 21: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

21

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 358HSeparable Stainless Steel Probe with HART®-communication

Ceramic Sensor

accuracy according to IEC 60770:0.1 % FSO

Nominal pressure

from 0 ... 60 cmH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 39.5 mm cable and sensor section separable HART® communication (setting of

offset, span and damping) permissible temperatures up to 85 °C high long-term stability

Optional versions

IS-version zone 0 cable protection via corrugated pipe diaphragm 99.9 % AI2O3

The separable stainless steel probe LMK 358H has been designed for level measurement in waste water, waste and higher viscosity media. Basic element is a capacitive ceramic sensor.

In order to facilitate stock-keeping and mainte-nance the transmitter head is plugged to the ca-ble assembly with a connector and can be changed easily.

Preferred areas of use are

Water ground water level measurementrain spillway basin

Sewage waste water treatmentwater recyclingFuel / Oil level monitoring in open tankswith low filling heightsfuel storagetank farmsbiogas plants

Page 22: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

22

LMK 358HStainless Steel Probe Technical Data

pressure and level

Input pressure range 1

Nominal pressure gauge [bar] 0.06 0.16 0.4 1 2 5 10Level [mH2O] 0.6 1.6 4 10 20 50 100Overpressure [bar] 2 4 6 8 15 25 351 On customer request we adjust the devices by software on the required pressure ranges, within the turn-down-possibility (starting at 0.02 bar)

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC with HARTcommunication VS rated = 24 VDC

Option IS-protection 2-wire: 4 ... 20 mA / VS = 12 ... 28 VDC with HARTcommunication VS rated = 24 VDC

PerformanceAccuracy 2 PN ≥ 160 mbar TD ≤ 1:5 ≤ ± 0.2 % FSO

TD > 1:5 ≤ ± [0.2 + 0.03 x TD] % FSOTDmax = 1:10

PN < 160 mbar ≤ ± [0.2 + 0.1 x TD] % FSO TDmax = 1:3PN ≥ 1 bar TD ≤ 1:5 ≤ ± 0.1 % FSO

TD > 1:5 ≤ ± [0.1 + 0.02 x TD] % FSOTDmax = 1:10

Permissible load Rmax = [(VS – VS min) / 0.02 A] Ω load at HART-communication: Rmin = 250 ΩLong term stability ≤ ± (0.1 x turn-down) % FSO / year at reference conditionsInfluence effects supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩTurn-on time 850 msecMean response time 140 msec – without consideration of electronic damping measuring rate 7/secMax. response time 380 msecAdjustability configuration of following parameters possible (interface / software necessary 3)

- electronic damping 0 ... 100 sec - offset: 0 ... 80 % FSO

- turn-down of span: max. 1:102 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability) 3 software, interface, and cable have to be ordered separately (software appropriate for Windows® 95, 98, 2000, NT Version 4.0 or higher, and XP) Thermal effects (Offset and Span) / - permissible temperaturesTolerance band ≤ ± (0.2 x turn-down) % FSOTC, average ± (0.02 x turn-down) % FSO / 10 Kin compensated range -20 ... 80 °CPermissible temperatures medium: -25 ... 85 °C

electronic / environment: -25 … 85 °Cstorage: -25 ... 85 °C

Electrical protection 4

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613264 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Mechanical stabilityVibration 4 g (according to: DIN EN 60068-2-6)Electrical connectionCable with sheath material 5 PVC (-5 … 70 °C) grey

PUR (-25 … 70 °C) black FEP6 (-25 … 70 °C) black TPE (-25 …85 °C) blue

5 shielded cable with integrated air tube for atmospheric pressure reference 6 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Materials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM

EPDM others on request

Diaphragm standard: ceramics Al2O3 96 %option: ceramics Al2O3 99.9 %

Protection cap POMExplosion protectionApproval DX15A-LMK 358H IBExU 10 ATEX 1186 X

zone 0 7: II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T85 °C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 13,2 nF , Li = 0 µH,the supply connections have an inner capacity of max. 27 nF opposite the enclosure

Permissible media temperature in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barzone 1 or higher: -25 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

7 for optional stainless steel pipe following designation is valid: "II 1G Ex ia IIC T4" (zone 0)

LMK 358 HTechnical Data

www.bdsensors.com

Page 23: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

23LMK 358 HTechnical Data

LMK 358HStainless Steel Probe Technical Data

www.bdsensors.com

MiscellaneousOption cable protection stainless steel pipe for probe in stainless steel: available as compact product (standard: stainless

steel pipe with a total length up to 2 m possible; other lengths on request)Current consumption max. 21 mA Weight approx. 650 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current) HART® connector

Pin configurationElectrical connection Binder series 723 8 (5-pin) cable colours (IEC 60575)

Supply +Supply –

3 1

wh (white) gn (brown)

Shield 5 gnye (green-yellow)8 in separated version Dimensions (in mm)

separated version optionally with corrugated pipe

HART® is a registered trade mark of HART Communication Foundation; Windows® is a registered trade mark of Microsoft Corporation

psupply +

supply –

VS

I

Page 24: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

24

www.bdsensors.com

LMK 358 HOrdering code

- - - - - - - - - -Pressure

4 4 54 4 6

Input [mH2O] [bar]0.60 0.06 0 6 0 01.60 0.16 1 6 0 04.00 0.40 4 0 0 010 1.0 1 0 0 120 2.0 2 0 0 150 5.0 5 0 0 1

100 10 1 0 0 29 9 9 9 consult

Housing19 consult

Diaphragm2C9 consult

Output

9 consultSeals

139 consult

Electrical connection123

TPE-cable 49 consult

Accuracy PN ≥ 1 bar 0.1 % 1 PN < 1 bar 0,2 % B

customer 9 consultCable length

in m 9 9 9Special version

0 0 0

9 9 9 consult

9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 stainless steel pipe is not part of the supply

HART® is a registered trade mark of HART Communication Foundation

13.01.2016

1

H

I

1 0 6

3

1

4 … 20 mA / 2-wire

PVC-cable

1

with stainless steel pipe

Ordering code LMK 358H

HART®-communication

Stainless steel 1.4404 (316L)

customer

in barin mH2O

LMK 358H

Intrinsic safety 4 … 20 mA / 2-wire

© 2

016

BD

|SE

NS

OR

S G

mbH

– T

he s

peci

ficat

ions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

g at

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.customer

FKM

customer

Ceramics Al2O3 96%

HART®-communication

customer

cable protection with stainless steel corrugated pipe

PUR-cable

customerwith pipe length in m

FEP-cable

Ceramics Al2O3 99.9%

EPDMcustomer

customer

0

2prepared for mounting

1

standard

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 25: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

25

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 305

Slimline Probe

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure

from 0 ... 1 mH2O up to 0 ... 250 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 19 mm for cramped areas small thermal effect excellent long term stability excellent linearity

Optional versions

different kinds of cable customer specific versions

e.g. special pressure ranges

The slimline probe LMP 305 with silicon stainless steel sensor is designed for continous level mea-surement in confined space conditions. Permiss-ible media are clean or waste water and thin flu-ids.

A piezoresistiv stainless steel sensor with low thermal error, an excellent linearity and a long term stability, is basis of LMP 305.

Preferred areas of use are

Waterlevel measurement in confined space conditionsground water monitoringdepth or level measurement in wells and open watersdrinking water systemlevel measurement in container

PROBES

Page 26: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

26

www.bdsensors.com

LMP 305Technical Data

LMP 305Stainless Steel Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 1 1 1 1 3 3 6 6 20 20 60 60 100

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC

PerformanceAccuracy standard: nominal pressure > 0.4 bar: ≤ ± 0.35 % FSO

nominal pressure ≤ 0.4 bar: ≤ ± 0.50 % FSOoption: nominal pressure > 0.4 bar: ≤ ± 0.25 % FSO

Permissible load Rmax = [(VS – VS min) / 0,02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time < 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (Offset and Span)Nominal pressure PN [bar] ≤ 0.1 ≤ 0.25 ≤ 0.4 ≤ 1 > 1Tolerance band [% FSO] ≤ ± 2 ≤ ± 1.5 ≤ ± 1 ≤ ± 1 ≤ ± 0.75TC, average [% FSO / 10 K] ± 0.3 ± 0.2 ± 0.14 ± 0.1 ± 0.07in compensated range [°C] 0 ... 50 0 ... 70Permissible temperaturesPermissible temperatures medium: -10 ... 70 °C

storage: -25 ... 70 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Electrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) blackFEP4 (-10 … 70 °C) black others on request

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM / EPDM Diaphragm stainless steel 1.4435 (316L)Protection cap POMCable sheath PVC / PUR / FEPMiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

Current consumption signal output current: max. 25 mAWeight approx. 100 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current)

supply –

VS

p

I

A supply +

Page 27: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

27

www.bdsensors.com

LMP 305Stainless Steel Probe Technical Data

www.bdsensors.com

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

wh (white)bn (brown)

Shield gnye (green-yellow)Dimensions (in mm)

Protection cap removable

© 2

015

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

LMP 305Technical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Page 28: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

28 LMP 305Ordering code

- - - - - - - - -Pressure

4 0 04 0 1

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output19 consult

Seals139 consult

Accuracystandard for PN > 0.4 bar 0.35 % 3standard for PN ≤ 0.4 bar 0.5 % 5option for PN > 0.4 bar 0.25 % 2

9 consultElectrical connection

1239 consult

Cable lengthin m 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

01.06.2013

customer

FKMEPDM

customer

customer

customer

in mH2O

Stainless steel 1.4435 (316L)

Stainless steel 1.4404 (316L)customer

Ordering code LMP 305

PVC-cable

LMP 305

in bar

customer

PUR-cable

standardcustomer

customer

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

FEP-cable

1

1

1

4 … 20 mA / 2-wire

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

www.bdsensors.com

Page 29: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

29

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 307

Stainless Steel Probe

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % / 0.1 % FSO

Nominal pressure

from 0 ... 1 mH2O up to 0 ... 250 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 20 mA / 0 ... 10 Vothers on request

Special characteristics

diameter 26,5 mm small thermal effect excellent accuracy excellent long term stability

Optional versions

IS-protection zone 0 SIL 2 (Safety Integrity Level) cable protection via corrugated pipe different kinds of cables

different kinds of seal materials

The stainless steel probe LMP 307 is designed for continuous level measurement in water and clean or waste fluids.

Basic element is a high quality stainless steel sen-sor with high requirements for exact measurement with excellent long term stability.

Preferred areas of use are

Water / filtrated sewagedrinking water systemground water level measurementrain spillway basinpump and booster stationslevel measurement in containerwater treatment plantswater recycling

Fuel / Oilfuel storagetank farm

PROBES

www.bdsensors.com

Page 30: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

30

www.bdsensors.com

LMP 307Technical DataLMP 307Stainless Steel Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 0.5 1 1 2 5 5 10 10 20 40 40 80 80Burst pressure > [bar] 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Option Ex-protection 2-wire: 4 ... 20 mA / VS = 10 ... 28 VDC SIL-version: VS = 14 … 28 VDC

Options 3-wire 3-wire: 0 ... 20 mA / VS = 14 ... 30 VDC0 ... 10 V / VS = 14 ... 30 VDC

PerformanceAccuracy standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO

nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSOoption 2: for all nominal pressures: ≤ ± 0.1 % FSO

Permissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ωcurrent 3-wire: Rmax = 500 Ωvoltage 3-wire: Rmin = 10 kΩ

Influence effects supply: 0.05 % FSO / 10 Vload: 0.05 % FSO / kΩ

Long term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time 2-wire: < 10 msec; 3-wire: < 3 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (Offset and Span)Nominal pressure PN [bar] < 0.40 > 0.40Tolerance band [% FSO] ≤ ± 1 ≤ ± 0.75in compensated range [°C] 0 ... 70Permissible temperaturesPermissible temperatures medium: -10 ... 70 °C storage: -25 ... 70 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Electrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey PUR (-10 … 70 °C) black FEP4 (-10 … 70 °C) black 3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)

Seals FKMothers on request

Diaphragm stainless steel 1.4435 (316L)Protection cap POMExplosion protection (only for 4 ... 20 mA / 2-wire)ApprovalsDX19-LMP 307

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 nF, Li ≈ 0 µH,the supply connections have an inner capacity of max. 27 nF to the housing

Ambient temperature range in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barin zone 1 or higher: -20 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

MiscellaneousOption SIL5 2 application according to IEC 61508 / IEC 61511Current consumption signal output current: max. 25 mA / signal output voltage: max. 7 mAWeight approx. 200 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECATEX Directive 94/9/EG5 not in combination with the accuracy 0.1%, only for 4...20mA / 2-wire

Page 31: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

31

www.bdsensors.com

LMP 307Technical DataLMP 307Stainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagrams2-wire-system (current) 3-wire-system (current / voltage)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

Signal + (only 3-wire)

wh (white)bn (brown)gn (green)

Shield gnye (green-yellow)Dimensions (in mm)

standard option

cable protectionwith corrugated pipe

Total length of devices with accuracy 0.1 % FSO IEC 60770 increases by 35 mm!

supply +

supply –

VS

p

I

A supply +

signal +

VS

A/V

p

I / U

supply –

Page 32: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

32 LMP 307Ordering code

- - - - - - - - - -Pressure

4 5 04 5 1

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output123E1S

9 consultSeals

19 consult

Accuracystandard for PN ≥ 0.4 bar 0.35 % 3standard for PN < 0.4 bar 0.5 % 5option 1 for PN ≥ 0.4 bar 0.25 % 2option 2 0.1 % 1

9 consultElectrical connection

1239 consult

Cable lengthin m

standard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

Special version0 0 0

9 9 9 consult

9 9 9 consult

1 not in combination with SIL2 cable with integrated air tube for atmospheric pressure reference

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

01.06.2013

3

FEP-cable

with pipe length in m

ES

2

01

customer

customer

PVC-cable

in bar

customer

cable protection with

4 … 20 mA / 2-wire

2

2

customer

customer

standard

customer

customer

SIL2 4 … 20 mA / 2-wire

0 … 10 V / 3-wire

in mH2O

Stainless steel 1.4404 (316L)

SIL2 with Intrinsic safety

stainless steel corrugated pipe

4 … 20 mA / 2-wire

PUR-cable

customer

Stainless steel 1.4435 (316L)

LMP 307

0 … 20 mA / 3-wire

Intrinsic safety 4 … 20 mA / 2-wire

1

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

FKM

Ordering code LMP 307

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 33: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

33

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 307TLevel andTemperature Transmitter

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure / nominal temperature

from 0 ... 1 mH2O up to 0 ... 250 mH2O

from 0 ... 30 °C up to 0 ... 70 °C

others on request

Output signals

2-wire: 4 ... 20 mA (pressure)

2-wire: 4 ... 20 mA (temperature)

Special characteristics

diameter 26,5 mm separate output signals

for pressure and temperature ranges easy handling low maintenance and wiring costs

Optional versions

different kinds of cables

different kinds of seal materials customer specific versions

BD|SENSORS has developed the stainless steel submersible probe LMP 307T for continuous level and temperature measurement in water and in clean to lightly-soiled liquids. The advantage: simultaneous recording of level and temperature with separate independent signal ampli-fication. The maintenance and wiring costs are con-siderably reduced.

In addition to classical signal processing of the level, an additional signal circuit independent of the level which converts the temperature signal into a 4 … 20 mA analogue signal in 2-wire technology is provided.

Typical application areas are, for example, drinking water purification, monitoring of rainwater overflow basins and river courses, in addition to level meas-urement in containers or tank batteries.

Preferred areas of use are

Water / filtrated sewagee.g. drinking water system

water recycling

Fuel / Oile.g. tank farm

PROBES

Page 34: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

34

LMP 307TStainless Steel Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 25Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 0.5 1 1 2 5 5 10 10 20 40 40 80 80Burst pressure > [bar] 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120

Input temperature rangeTemperature measuring rangestandard 0 … 30 °C 0 … 50 °C 0 … 70 °C others on request11 min. temperature range: 30°C; max. temperature range: 80°C

min. temperature: -10°C; max. temperature: 70 °COutput signal / Supply2-wire (pressure) 2 4 ... 20 mA / VS = 10 ... 30 VDC

2-wire (temperature) 2 4 ... 20 mA / VS = 10 ... 30 VDC2 the circuits are galvanically isolated from each otherPerformanceAccuracy (pressure) 3 standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO

nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0,4 bar: ≤ ± 0,25 % FSO

Accuracy (temperature) 4 ≤ ± 1 °CPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time < 10 ms (for output signal 2-wire (pressure))3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 Pt 100 class B; compensation time up to 1h depending on constant temperature and environmental respectively mass conditionsThermal effects (Offset and Span)Nominal pressure PN [bar] < 0.40 > 0.40Tolerance band [% FSO] ≤ ± 1 ≤ ± 0.75in compensated range [°C] 0 ... 70Permissible temperaturesPermissible temperatures medium: -10 ... 70 °C

storage: -25 ... 70 °CElectrical protection 5

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613265 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 6 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) blackFEP7 (-10 … 70 °C) black others on request

6 cable with integrated air tube for atmospheric pressure reference7 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)

Seals FKMothers on request

Diaphragm stainless steel 1.4435 (316L)Protection cap POMCable sheath PVC, PUR, FEPMiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

Current consumption signal output current: max. 25 mA / signal output voltage: max. 7 mAWeight approx. 200 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC

LMP 307 TTechnical Data

www.bdsensors.com

Page 35: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

35LMP 307 TTechnical DataLMP 307TStainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagram

2x2-wire-system (current)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply P+Supply P–Supply T+Supply T–

wh (white)bn (brown)gy (gray)pk (pink)

Shield gnye (green-yellow)Dimensions (in mm)

I

I

+supply P+

supply P-

supply T+

supply T-

VS

Ap

TVS

A

+

www.bdsensors.com

Page 36: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

36

www.bdsensors.com

LMP 307 TOrdering code

- - - - - - - - - - -Pressure

4 5 54 5 6

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultInput temperature °C

0 … 30 0 0 0 x 3 00 … 50 0 0 0 x 5 00 … 70 0 0 0 x 7 0

9 9 9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output pressure1

Output temperature1

Seals19 consult

Accuracystandard for PN ≥ 0.4 bar 0.35 % 3standard for PN < 0.4 bar 0.5 % 5option 1 for PN ≥ 0.4 bar 0.25 % 2

9 consultElectrical connection

1239 consult

Cable lengthin m

standard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

15.04.2014

Ordering code LMP 307T

customer

customer

customer

customer

customer

LMP 307T

Stainless steel 1.4404 (316L)

in bar

4 … 20 mA / 2-wire

1

FKM

in mH2O

Stainless steel 1.4435 (316L)

PUR-cableFEP-cable

standard

4 … 20 mA / 2-wire

PVC-cable

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

1

customer

1

customer

customer

- - - - - - - - - - -Pressure

4 5 54 5 6

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultInput temperature °C

0 … 30 0 0 0 x 3 00 … 50 0 0 0 x 5 00 … 70 0 0 0 x 7 0

9 9 9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output pressure1

Output temperature1

Seals19 consult

Accuracystandard for PN ≥ 0.4 bar 0.35 % 3standard for PN < 0.4 bar 0.5 % 5option 1 for PN ≥ 0.4 bar 0.25 % 2

9 consultElectrical connection

1239 consult

Cable lengthin m

standard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

15.04.2014

Ordering code LMP 307T

customer

customer

customer

customer

customer

LMP 307T

Stainless steel 1.4404 (316L)

in bar

4 … 20 mA / 2-wire

1

FKM

in mH2O

Stainless steel 1.4435 (316L)

PUR-cableFEP-cable

standard

4 … 20 mA / 2-wire

PVC-cable

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

1

customer

1

customer

customer

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 37: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

37

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 308Separable Stainless Steel Probe

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO / 0.1 % FSO

Nominal pressure

from 0 ... 1 mH2O up to 0 ... 250 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 35 mm cable and sensor section separable excellent accuracy excellent long term stability

Optional versions

IS-version zone 0 SIL 2 (Safety Integrity Level) cable protection via corrugated pipe mounting accessories as cable gland

and terminal clamp of stainless steel different kinds of cables

different kinds of seal materials

The separable stainless steel probe LMP 308 is designed for the continually level measurement of water and thin fluids.

In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.

Preferred areas of use are

Water / filtrated sewageground water level measurementlevel measurement in wells and open watersrain spillway basinlevel measurement in containerwater treatment plantswater recycling

PROBES

Page 38: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

38

LMP 308Stainless Steel Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.10 0.16 0.25 0.40 0.60 1 1.6 2.5 4 6 10 16 25Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 0.5 1 1 2 5 5 10 10 20 40 40 80 80Burst pressure [bar] 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Option IS-protection 2-wire: 4 ... 20 mA / VS = 10 ... 28 VDC SIL-version: VS = 14 … 28 VDC

PerformanceAccuracy 1 standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO

nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSOoption 2: for all nominal pressures: ≤ ± 0.1 % FSO

Permissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time < 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Nominal pressure PN [bar] < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 1 ≤ ± 0.75in compensated range [°C] 0 ... 70Permissible temperaturesPermissible temperatures medium: -20 ... 70 °C storage: -25 ... 70 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-20 … 70 °C) blackFEP4 (-20 … 70 °C) blackothers on request

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM

EPDMothers on request

Diaphragm stainless steel 1.4435 (316L)Protection cap POMExplosion protectionApprovalsDX19-LMP 308

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0nF, Li ≈ 0µH, the supply connections have an inner capacity of max. 27 nF to the housing

Ambient temperature range in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barin zone 1 or higher: -20 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

MiscellaneousOption SIL5 2 application according to IEC 61508 / IEC 61511Current consumption signal output current: max. 25 mA Weight approx. 250 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECATEX Directive 94/9/EG5 not in combination with the accuracy 0.1%

LMP 308Technical Data

www.bdsensors.com

Page 39: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

39LMP 308Technical Data

LMP 308Stainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagram

2-wire-system (current) connector

Pin configurationElectrical connection Binder series 723 6 (5-pin) cable colours (IEC 60575)

Supply +Supply –

31

wh (white)bn (brown)

Shield 5 gnye (green-yellow)6 in separated versionDimensions (in mm)

standard option

separated version version withcorrugated pipe

Total length of devices with accuracy 0.1 % FSO IEC 60770 increases by 16 mm! (standard, Ex-protection and SIL-version)

p supply +

supply –

VS

I

www.bdsensors.com

Page 40: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

40

www.bdsensors.com

LMP 308Ordering code

- - - - - - - - - -Pressure

4 4 04 4 1

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm19 consult

Output1E

1S

9 consultSeals

139 consult

Electrical connection1239 consult

Accuracy0.35 % 3

0.5 % 50.25 % 2

0.1 % 19 consult

Cable lengthin m 9 9 9

Version0 0 0

9 9 9 consult

9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 not in combination with SIL3 stainless steel pipe is not part of the supply

15.04.2015

2

customer

3

standard

stainless steel corrugated pipewith pipe length in m

01

0

6

31cable protection with

prepared for mounting

PUR-cableFEP-cable

option 1 for PN ≥ 0.4 bar

FKM

customer

EPDMcustomer

PVC-cable

ES4 … 20 mA / 2-wirecustomer

Stainless steel 1.4435 (316L)customer

4 … 20 mA / 2-wire

1

Intrinsic safety 4 … 20 mA / 2-wireSIL2 4 … 20 mA / 2-wire

Stainless steel 1.4404 (316L)

SIL2 with Intrinsic safety

customer

in barin mH2O

customer

© 2

015

BD|S

ENSO

RS

Gm

bH -

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

g at

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

Ordering code LMP 308

LMP 308

1

1

consult

option 2customer

standard for PN ≥ 0.4 barstandard for PN< 0.4 bar

with stainless steel pipe

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 41: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

41

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 306

Stainless Steel Probe

Ceramic Sensor

accuracy according to IEC 60770: 0.5 % FSO

Nominal pressure

from 0 ... 6 mH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 17 mm suitable for hydrostatic level

measurement e.g. 3/4" pipes

excellent linearity excellent long term stability

Optional versions

different cable materials customer specific versions

e.g. special pressure ranges

The slimline probe LMK 306 with ceramic sensor has been especially designed for the continuous level measurement at confined space conditions. Permissible media are clean or slightly contami-nated water and thin fluids.

Different cable sheath materials are available in order to achieve maximum media compatibility.

Preferred areas of use are

Waterlevel measurement atconfined space conditionsground water monitoringdepth or level measurement in wellsdrinking water abstractionlevel measurement in open tanks

Page 42: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

42 LMK 306Technical DataLMK 306Stainless Steel Probe Technical Data

pressure measurement

Input pressure rangeNominal pressure gauge [bar] 0.6 1 1.6 2.5 4 6 10 16 20Level [mH2O] 6 10 16 25 40 60 100 160 200Overpressure [bar] 2 2 4 4 10 10 20 40 40Burst pressure ≥ [bar] 4 4 5 5 12 12 25 50 50

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC

PerformanceAccuracy ≤ ± 0.5 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩResponse time ≤ 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span) / Permissible temperaturesThermal error ≤ ± 0.2 % FSO / 10 K

in compensated range -25 ... 70 °CPermissible temperatures medium: -10 ... 70 °C

storage: -25 ... 70 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic protection emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) blackFEP4 (-10 … 70 °C) black

3 shielded cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKMDiaphragm ceramics Al2O3 96 %Protection cap POMMiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

Current consumption max. 25 mAWeight approx. 100 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

wh (white)bn (brown)

Shield gnye (green-yellow)

psupply +

supply –

VS

I

www.bdsensors.com

Page 43: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

43

LMK 306Stainless Steel Probe Technical Data

www.bdsensors.com

Dimensions (in mm)

Accessories

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, steel, zinc plated Z100528Terminal clamp, stainless steel 1.4301 (304) Z100527

protection cap removable

LMK306_E_011215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

LMK 306Technical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 44: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

44

www.bdsensors.com

LMK 306Ordering code

- - - - - - - - -Pressure

3 7 03 7 1

Input [mH2O] [bar]6 0.60 6 0 0 0

10 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm29 consult

Output19 consult

Seals19 consult

Accuracy0.5 % 5

9 consultElectrical connection

1239 consult

Cable lengthin m 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

1

PUR-cable

standard

customer

customer

FEP-cable

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

4 … 20 mA / 2-wire

customer

customer

customer

customerFKM

LMK 306

Ordering code LMK 306

1

1PVC-cable

customer

in mH2O

Stainless steel 1.4404 (316L)

customer

Ceramics Al2O3 96%

in bar

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 45: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

45

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 307

Stainless Steel Probe

Ceramic Sensor

accuracy accordingto IEC 60770: 0.5 % FSO

Nominal pressure

from 0 ... 4 mH2O up to 0 ... 250 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 20 mA / 0 ... 10 Vothers on request

Special characteristics

diameter 27 mm good linearity

good long term stability easy handling

Optional versions

IS-protection SIL 2 (Safety Integrity Level)

according to IEC 61508 / IEC 61511 different kinds of cables and elasto-

meres customer specific versions

e. g. special pressure ranges

The level transmitter LMK 307 is designed for continuous level measurement in water or waste water applications. Basic element is a flush mounted ceramic sensor.

Suitable for all fluids which are compatible with media wetted materials. Different cable and elas-tomer matierals can be offered according to the customer-specific operating conditions.

Preferred areas of use are

Waterdrinking water systemground water monitoringstorm water systems

Sewagewaste water treatmentwater recyclingdumpsite

Fuel / Oilfuel storagetank farmbiogas plants

Page 46: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

46

LMK 307Stainless Steel Probe Technical Data

pressure measurement

Input pressure rangeNominal pressure gauge [bar] 0.4 0.6 1 1.6 2.5 4 6 10 16 25Level [mH2O] 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 2 2 2 4 4 10 10 20 40 40Burst pressure [bar] 4 4 4 5 5 12 12 25 50 50

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Option IS-protection 2-wire: 4 ... 20 mA / VS = 10 ... 28 VDC SIL-version: VS = 14 … 28 VDC

Options 3-wire 3-wire: 0 ... 20 mA / VS = 14 ... 30 VDC0 ... 10 V / VS = 14 ... 30 VDC

PerformanceAccuracy ≤ ± 0.5 % FSOPermissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω

current 3-wire: Rmax = 500 Ωvoltage 3-wire: Rmin = 10 k Ω

Influence effects supply: 0.05 % FSO / 10 Vload: 0.05 % FSO / kΩ

Response time ≤ 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Thermal error ≤ ± 0.2 % FSO / 10 K

in compensated range -25 … 70 °CPermissible temperaturesPermissible temperatures medium: -10 ... 70 °C

storage: -25 ... 70 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic protection emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material3 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) blackFEP4 (-10 … 70 °C) black

3 shielded cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM

EPDM Diaphragm ceramics Al2O3 96 % Protection cap POMExplosion protection (only for 4 … 20 mA / 2-wire)ApprovalsDX19-LMK 307

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0nF, Li ≈ 0 µH,the supply connections have an inner capacity of max. 27 nF to the housing

Ambient temperature range in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barin zone 1: -20 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

MiscellaneousOption SIL5 2 application according to IEC 61508 / IEC 61511Current consumption signal output current: max. 25 mA

signal output voltage: max. 7 mAWeight approx. 250 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECATEX Directive 94/9/EG5 only for 4...20mA / 2-wire

LMK 307Technical Data

www.bdsensors.com

Page 47: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

47

LMK 307Stainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagrams2-wire-system (current) 3-wire-system (current / voltage)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

Signal + (only 3-wire)

wh (white)bn (brown)gn (green)

Shield gnye (green-yellow)Dimensions (in mm)

Accessories

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, steel, zinc plated Z100528Terminal clamp, stainless steel 1.4301 (304) Z100527

protection cap removable

supply +

supply –

VS

p

I

A supply +

signal +

VS

A/V

p

I/U

supply –

LMK307_E_011215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

LMK 307Technical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 48: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

48

www.bdsensors.com

LMK 307Ordering code

- - - - - - - - -Pressure

3 8 03 8 1

Input [mH2O] [bar]4.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm29 consult

Output123E1S

9 consultSeals

139 consult

Accuracy59 consult

Electrical connection1239 consult

Cable lengthin m

standard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

01.06.2013

1

customer

FKM

PUR-cable

EPDM

customer

SIL2 4 … 20 mA / 2-wire

1

1

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

in bar

4 … 20 mA / 2-wire

in mH2O

ES

Ordering code LMK 307

LMK 307

Intrinsic safety 4 … 20 mA / 2-wire

Ceramics Al2O3 96%

Stainless steel 1.4404 (316L)

customer

customer

customer

FEP-cable

standard

customer

PVC-cable

customer

0.5 %

4 … 20 mA / 2-wire0 … 20 mA / 3-wire

SIL2 with Intrinsic safety

0 … 10 V / 3-wire

customer

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 49: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

49

www.bdsensors.com

PROBES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 307TLevel andTemperature Transmitter

Ceramic Sensor

accuracy according to IEC 60770:0.5 % FSO

Nominal pressure / nominal temperature

from 0 ... 4 mH2O up to 0 ... 250 mH2O

from 0 ... 30 °C up to 0 ... 70 °C

others on request

Output signals

2-wire: 4 ... 20 mA (pressure)

2-wire: 4 ... 20 mA (temperature)

Special characteristics

diameter 26,5 mm separate output signals

for pressure and temperature ranges good lang term stability easy handling low maintenance and wiring costs

Optional versions

different kinds of cables

different kinds of seal materials customer specific versions

BD|SENSORS has developed the stainless steel submersible probe LMK 307T with flush mounted ceramic sensor for continuous level and temperature measurement in water or waste water applications.

The advantage: simultaneous recording of level and temperature with separate independent signal ampli-fication. The maintenance and wiring costs are con-siderably reduced.

In addition to classical signal processing of the level, an additional signal circuit independent of the level which converts the temperature signal into a 4 … 20 mA analogue signal in 2-wire technology is provided.

Preferred areas of use are

Watere.g. drinking water system, RÜBsground water monitoringstorm water systems

Sewagewaste water treatment, water recycling,dumpsite, waste water tanks

Fuel / Oilfuel storagetank farm, biogas plants

Page 50: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

50

www.bdsensors.com

LMK 307TStainless Steel Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0,4 0,6 1 1,6 2,5 4 6 10 16 25Level [mH2O] 4 6 10 16 25 40 60 100 160 250Overpressure [bar] 1 2 2 4 4 10 10 20 40 40Burst pressure > [bar] 2 4 4 5 5 12 12 25 50 50

Input temperature rangeTemperature measuring rangestandard 0 … 30 °C 0 … 50 °C 0 … 70 °C others on request11 min. temperature range: 30°C; max. temperature range: 80°C

min. temperature: -10°C; max. temperature: 70 °COutput signal / Supply2-wire (pressure) 2 4 ... 20 mA / VS = 10 ... 30 VDC

2-wire (temperature) 2 4 ... 20 mA / VS = 10 ... 30 VDC2 the circuits are galvanically isolated from each otherPerformanceAccuracy (pressure) 3 ≤ ± 0.5 % FSOAccuracy (temperature) 4 ≤ ± 1 °CPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.3 % FSO / year at reference conditionsResponse time < 10 ms (for output signal 2-wire (pressure))3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)4 Pt 100 class B; compensation time up to 1h depending on constant temperature and environmental respectively mass conditionsThermal effects (Offset and Span)Thermal error ≤ ± 0.2 % FSO / 10 K

in compensated range -25 … 70 °CPermissible temperaturesPermissible temperatures medium: -10 ... 70 °C

storage: -25 ... 70 °CElectrical protection 5

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613265 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 6 PVC (-5 … 70 °C) grey

PUR (-10 … 70 °C) blackFEP7 (-10 … 70 °C) black others on request

6 cable with integrated air tube for atmospheric pressure reference7 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316L)

SealsFKMEPDMothers on request

Diaphragm ceramics Al2O3 96%Protection cap POMCable sheath PVC, PUR, FEPMiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

Current consumption max. 25 mA Weight approx. 250 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC

LMK 307TTechnical Data

Page 51: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

51

www.bdsensors.com

LMK 307TTechnical DataLMK 307TStainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagram

2x2-wire-system (current)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply P+Supply P–Supply T+Supply T–

wh (white)bn (brown)gy (gray)pk (pink)

Shield gnye (green-yellow)Dimensions (in mm)

I

I

+supply P+

supply P-

supply T+

supply T-

VS

Ap

TVS

A

+

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Page 52: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

52

www.bdsensors.com

LMK 307TOrdering code

- - - - - - - - - - -Pressure

3 8 A3 8 B

Input [mH2O] [bar]4.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2

9 9 9 9 consultInput temperature °C

0 … 30 0 0 0 x 3 00 … 50 0 0 0 x 5 00 … 70 0 0 0 x 7 0

9 9 9 9 9 9 consultHousing

19 consult

Diaphragm29 consult

Output pressure1

Output temperature1

Seals139 consult

Accuracy0.5 % 5

9 consultElectrical connection

1239 consult

Cable lengthin m

standard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

22.04.2014 This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

1

customer

1

customer

customer

FEP-cable

standard

4 … 20 mA / 2-wire

PVC-cable

customer

FKM

in mH2O

Ceramic Al2O3 96 %

LMK 307T

in bar

4 … 20 mA / 2-wire

1

customer

customer

Stainless steel 1.4404 (316L)

Ordering code LMK 307T

customer

customer

EPDM

PUR-cable

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 53: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

53

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 382

Stainless Steel Probe

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure

from 0 ... 40 cmH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 … 10 Vothers on request

Special characteristics

diameter 39.5 mm especially for sewage, viscous

and pasty media

Optional versions

IS-protection zone 0 mounting with stainless steel pipe flange version diaphragm 99.9 % AI2O3

different kinds of cables different kinds of elastomers

The stainless steel probe LMK 382 has been designed for continous level measurement in waste water, waste and higher viscosity media.

Basic element is a robust and high overpressure capable capacitive ceramic sensor e.g. for low levels easily.

Preferred areas of use are

Waterdrinking water abstraction

Sewagewaste water treatmentwater recyclingFuel / Oillevel monitoring in open tankswith low filling heightsfuel storagetank farms / biogas plants

PROBES

Page 54: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

54

LMK 382Stainless Steel Probe Technical Data

pressure measurement

Input pressure range Nominal pressure gauge [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 20Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 200Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35 45 45

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC

Option IS-protection 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC

Option 3-wire 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC

PerformanceAccuracy 1 standard: ≤ ± 0.35 % FSO

option: ≤ ± 0.25 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsTurn-on time 700 msecMean response time < 200 msec measuring rate 5/secMax. response time 380 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Thermal error ≤ ± 0.1 % FSO / 10 K

in compensated range 0 ... 70 °CPermissible temperaturesPermissible temperatures medium: -25 ... 125 °C

electronics / environment: -25 ... 125 °Cstorage: -25 ... 125 °C

Electrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connection (only for 4 … 20 mA / 2-wire)Cable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-25 … 70 °C) blackFEP4 (-25 … 70°C) blackTPE (-25 … 125 °C) blue

3 shielded cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing stainless steel 1.4404 (316 L)Seals FKM

FFKMEPDMothers on request

Diaphragm standard: ceramics Al2O3 96 %Option: ceramics Al2O3 99.9 %

Nose cone POMExplosion protection Approval DX14-LMK 382 IBExU05ATEX1070 X

zone 0 5: II 1G Ex ia IIB T4 Gazone 20: II 1D Ex ia IIIC T85 °C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 27 nF, Li = 5 µHPermissible media temperature in zone 0: -10 ... 60 °C with patm 0.8 bar up to 1.1 bar

zone 1 and higher: -10 ... 70 °CConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

5 for optional stainless steel pipe following designation is valid: "II 1G Ex ia IIC T4 Ga" (zone 0)MiscellaneousCurrent consumption max. 21 mA Weight approx. 400 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC

LMK 382Technical Data

www.bdsensors.com

Page 55: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

55LMK 382Technical Data

LMK 382Stainless Steel Probe Technical Data

www.bdsensors.com

Wiring diagram2-wire-system (current) 3-wire-system (voltage)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

Signal + (only for 3-wire)

wh (white)bn (brown)gn (green)

Shield gnye (green-yellow)Dimensions (in mm)

LMK 382 standard LMK 382 with thread R1"for stainless steel pipe

LMK 382flange version

dimensions in mmdimen-sions

DN25 /PN40

DN40/PN40

DN50 /PN40

DN80 /PN16

D 115 150 165 200k 85 110 125 160

d4 68 88 102 138b 18 18 20 20f 2 3 3 3n 4 4 4 8

d2 14 18 18 18

supply +

supply –

VS

p

I

A supply +

signal +

VS

p

U

supply –

V

www.bdsensors.com

Page 56: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

56 LMK 382Ordering code

- - - - - - - - -Pressure

5 6 55 6 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm2C9 consult

Output13E9 consult

Seals13

FFKM 79 consult

Electrical connection123

TPE-cable 49 consult

Accuracystandard 0.35 % 3option 0.25 % 2

9 consultCable length

in mstandard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

special length TPE 9 9 9Special version

0 0 0

5 1 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 stainless steel pipe is not part of the supply

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

01.06.2013

0 … 10 V / 3-wire

in bar

LMK 382

Ordering code LMK 382

in mH2O

Ceramics Al2O3 99.9%Ceramics Al2O3 96%

customer

customer

Stainless steel 1.4404 (316L)customer

4 … 20 mA / 2-wire

Intrinsic safety 4 … 20 mA / 2-wire

FEP-cablePUR-cable

customer

customer

FKM

customer

customer

EPDM

2prepared for mounting

customerflange version

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

1

standard

with stainless steel pipe 0

1

1

25

PVC-cable

- - - - - - - - -Pressure

5 6 55 6 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

19 consult

Diaphragm2C9 consult

Output13E9 consult

Seals13

FFKM 79 consult

Electrical connection123

TPE-cable 49 consult

Accuracystandard 0.35 % 3option 0.25 % 2

9 consultCable length

in mstandard: 3 m PVC 0 0 3standard: 5 m PVC 0 0 5

standard: 10 m PVC 0 1 0standard: 15 m PVC 0 1 5standard: 20 m PVC 0 2 0special length PVC 9 9 9

standard: 3 m PUR 0 0 3standard: 5 m PUR 0 0 5

standard: 10 m PUR 0 1 0standard: 15 m PUR 0 1 5standard: 20 m PUR 0 2 0special length PUR 9 9 9

standard: 5 m FEP 0 0 5standard: 10 m FEP 0 1 0special length FEP 9 9 9

special length TPE 9 9 9Special version

0 0 0

5 1 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 stainless steel pipe is not part of the supply

Standard lengths 3 / 5 / 10 / 15 / 20 m are available from stock, special lengths are manufactured order-related, price per meter (see above).

14.01.2013

0 … 10 V / 3-wire

in bar

LMK 382

Ordering code LMK 382

in mH2O

Ceramics Al2O3 99.9%Ceramics Al2O3 96%

customer

customer

Stainless steel 1.4404 (316L)customer

4 … 20 mA / 2-wire

Intrinsic safety 4 … 20 mA / 2-wire

FEP-cablePUR-cable

customer

customer

FKM

customer

customer

EPDM

2prepared for mounting

customerflange version

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

1

standard

with stainless steel pipe 0

1

1

25

PVC-cable

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 57: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

57

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 387

Stainless Steel Probe

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35 % FSO option: 0.25 % FSO

Nominal pressure

from 0 ... 1 mH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 10 Vothers on request

Special characteristics

diameter 22 mm diaphragm ceramics 96% Al2O3

good long-term stability especially for waste water,

Optional versions

diaphragm ceramics 99,9% Al2O3

IS-versionEx ia = intrinsically safe for gases and dust

mounting with stainless steel tube different kinds of cable different kinds of elastomer

The stainless steel probe LMK 387 was devel-oped for level and gauge measurement in wastewater, sludge or water courses. The me-chanical robustness of the front-flush ceramic di-aphragm facilitates an easy disassembly and cleaning of the probe in case of service.

Compared to the level probe LMK 382 the out-side-diameter is only 22mm, which allows an easy installation and backfitting in 1“ tubes or in cramped fitting conditions. An IS-version is also available.

Preferred areas of use

WaterGroundwater and level monitoring

Sewagewaste water treatmentwater recycling

Fuel and oilTank batteryBiogas plants

PROBES

Page 58: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

58

LMK 387Hydrostatic probe Technical data

Pressure and level

Input pressure range Nominal pressure gauge [bar] 0,1 0,16 0,25 0,4 0,6 1 1,6 2,5 4 6 10Level [mH2O] 1 1,6 2,5 4 6 10 16 25 40 60 100Overpressure [bar] 3 4 5 5 7 7 12 20 20 20 20Berst pressure ≥ [bar] 4 6 8 8 9 9 18 25 25 30 30Permissible vacuum [bar] -0.2 -0.3 -0.5 -1

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 12 ... 36 VDC

Option IS-version 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC

Option 3-wire: 0 … 10 V / VS = 14 ... 36 VDC

PerformanceAccuracy 1 standard: ≤ ± 0.35 % FSO

option: ≤ ± 0.25 % FSO others on requestPermissible load 2-wire: Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / yearTurn-on time 450 msecMean response time ≤ 70 msecMeasuring rate 80 Hz1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Tolerance band [% FSO] ≤ 1.0% FSO in compensated range -20 ... 80 °CPermissible temperaturesPermissible temperatures medium: -40 ... 85 °C

electronics / environment: -40 ... 85 °C storage: -40 ... 85 °C

Electrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable outlet shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges

absolute, the air tube is closed)Materials (media wetted)Housing standard: stainless steel 1.4404 (316 L) others on requestCable PVC (-5 … 70 °C) gray

PUR (-25 … 70 °C) blackFEP3 (-25 … 70 °C) blackTPE (-25 …125 °C) blue others on request

Seals (O-rings) standard: FKMoption: EPDM; FFKM (min. permissible temperature from -15 °C) others on request

Diaphragm standard: ceramics Al2O3 96% option: ceramics Al2O3 99,9%Protection cap POM3 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedIS-protectionApproval DX14B-LMK 387 IBExU 15 ATEX 1066 X

zone 0: II 1G Ex ia IIC T4 Ga zone 20: II 1D Ex ia IIIC T135 °C DaSafety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 49,2 nF; Li = 0 µH; the supply connections have an inner

capacity of max. 100 nF opposite the enclosurePermissible temperatures for environment

in zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barzone 1 and higher: -25 ... 65 °C

Connecting cables (by factory)

cable capacity: signal line/shield as well as signal line/signal line: 160 pF/mcable inductance: signal line/shield as well as signal line/signal line: 1 µH/m

MiscellaneousCurrent consumption max. 22 mA Weight approx. 180 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECPin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

signal + (only 3-wire)

wh (white)bn (brown)gn (green)

Shield gnye (green-yellow)

LMK 387Technical Data

www.bdsensors.com

Page 59: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

59LMK 387Technical Data

LMK 387Hydrostatic probe Technical data

www.bdsensors.com

Wiring diagrams

2-wire-system (current) 3-wire-system (voltage)

Dimensions (in mm)

standard

with protection cap without protection cap with thread R1/2“ formounting with stainless steel tube

option: screw-in version

G3/4“ G1/2“ open

Supply +

Supply –

VS

p

I

A Supply +

Supply +

VS

p

U

Supply –

V

Page 60: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

60 LMK 387Ordering code

- - - - - - - - - -Pressure

3 6 03 6 3 consult3 6 1

Input [mH2O] [bar]1 0.1 1 0 0 0

1.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2

9 9 9 9 consultHousing

19 consult

Design1AB

Diaphragm2C9 consult

Output13E9 consult

Seals13

FFKM 7 consult9 consult

Electrical connection12

FEP-cable 349 consult

Accuracystandard 0.35 % FSO 3option 0.25 % FSO 2

9 consultCable length

9 9 9Special version

0 0 05 0 29 9 9 consult

min. permissible temperature from -15 °Ccable with integrated air tube for atmospheric pressure referencestainless steel pipe is not part of the supply

11.11.2015

PVC-cable 2

prepared for mounting with st. steel pipe 3

2

2TPE-cable

FKM

Intrinsic safety 4 … 20 mA / 2-wire

Stainless steel 1.4404 (316L)customer

Ceramics Al2O3 99.9%

screw-in version G3/4" flush

Ceramics Al2O3 96%

1

© 2

015

BD

|SE

NS

OR

S G

mbH

- Th

e sp

ecifi

catio

ns g

iven

in th

is d

ocum

ent r

epre

sent

the

stat

e of

eng

inee

ring

at th

e tim

e of

pub

lishi

ng. W

e re

serv

e th

e rig

ht to

mak

e m

odifi

catio

ns to

the

spec

ifica

tions

and

mat

eria

ls.

gauge in mH2O

gauge in bar

customer

screw-in version G1/2" open

absolute in bar

customer

LMK 387

EPDM

customer

Ordering code LMK 387

PUR-cable

customer

standard

customer

0 … 10 V / 3-wire

in m

2

customer

4 … 20 mA / 2-wire

customer

probe

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 61: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

61

BD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 458

Probe ForMarine And Offshore

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.25 % FSOoption: 0.1 % FSO

Nominal pressure

from 0 ... 40 cmH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 39.5 mm LR-certificate (Lloyd´s Register) GL-certificate (Germanischer Lloyd) DVN-certificate (Det Norske Veritas) ABS-certificate (American Bureau of

Shipping) CCS-certificate

(China Classification Society) high overpressure resistance high long-term stability

Optional versions

diaphragm Al2O3 99.9 % different housing materials

(stainless steel, CuNiFe) IS-version zone 0 screw-in and flange version accessories e.g. assembling and probe

flange, mounting clamp

The hydrostatic probe LMK 458 has been devel-oped for measuring level in service and storage tanks and is as a consequence certificated for shipbuilding and offshore applications.

A permissible operating temperature of up to 125°C and the possibility to use the device inintrinsic safe areas enable to measure the pres-sure of various fluids under extreme conditions. The basis for the LMK 458 is a capacitive ceram-ic sensor element designed by BD|SENSORS, which offers a high overload resistance and me-dium compatibility.

Preferred areas of use are

Waterdrinking water abstractiondesalinization plant

Shipbuilding / Offshoreballast tanksmonitoring of a ship´s positionand draughtlevel measurement in ballast and storage tanks

PROBES

Page 62: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

62

LMK 458Hydrostatic Probe Technical Data

pressure measurement

Pressure rangesNominal pressure 1 [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 20Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 200Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35 45 45Permissible vacuum [bar] -0.2 -0.3 -0.5 -11 available in gauge and absolute; nominal pressure ranges absolute from 1 barOutput signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC VS rated = 24 VDC

Option IS-version 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC VS rated = 24 VDC

PerformanceAccuracy 2 standard: ≤ ± 0.25 % FSO option: for PN ≥ 0.6 bar 3: ≤ ± 0.1 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsInfluence effects supply: 0.05 % FSO / 10 V permissible load: 0.05 % FSO / kΩTurn-on time 700 msecMean response time < 200 msec mean measuring rate 5/secMax. response time 380 msec2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)3 Under the influence of disturbance burst according to EN 61000-4-4 (2004) +2 kV accuracy decreased to ≤ ± 0.25 % FSO.Thermal effects / Permissible temperaturesThermal error ≤ ± 0.1 % FSO / 10 K in compensated range -20 … 80 °CPermissible temperatures medium / electronics / environment: -25 ... 125 °C storage: -40 ... 125 °CElectrical protection 4

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to

- EN 61326 - Germanischer Lloyd (GL) - Det Norske Veritas (DNV)4 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference availableMechanical stabilityVibration 4 g (according to GL: curve 2 / according to DNV: Class B / basis: DIN EN 60068-2-6)Electrical connectionCable outlet shielded cable with integrated air tube for atmospheric reference (for nominal pressure ranges sealed

gauge and absolute, the air tube is plugged)

MaterialsHousing standard: stainless steel 1.4404 (316L)

option: CuNi10Fe1Mn (resistant against sea water) others on requestSeals (media wetted) standard: FKM

options: EPDM, FFKM (min. permissible temperature from -15 °C) others on requestDiaphragm standard: ceramics Al2O3 96 % option: ceramics Al2O3 99.9 %Cable sheath TPE -U (flame-resistant, halogen free, increased resistance against oil and gasoline,

resistant against salt, sea water, heavy oil)MiscellaneousOptionally cable protection stainless steel pipe for probe in stainless steel: available as compact product (standard: stainless steel pipe

with a total length up to 2 m possible; other lengths on request)Ingress protection IP 68Current consumption max. 21 mAWeight min. 650 g (without cable)CE-conformity EMC Directive: 2004/108/ECOption Pt 100 temperature element 5Temperature range -25 ... 125°CConnection temperature element 3-wireResistance 100 Ω at 0°C Temperature coefficient 3850 ppm/KSupply IS 0.3 ... 1.0 mA DC

Category of the environmentLloyd´s Register (LR) EMV1, EMV2, EMV3, EMV4 number of certificate: 13/20055Germanischer Lloyd (GL) D, EMC 1 number of certificate: 60 481 - 09 HHDet Norske Veritas (DNV) temperature: D humidity: B vibration: B

electromagnetic compatibility: B number of certificate: A-12144IS-protectionApproval DX14A-LMK 458 IBExU 07 ATEX 1180 X zone 0: II 1G Ex ia IIB T4 Ga

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 105 nF; Li = 5 µH; the supply connections have an inner capacity of max. 140 nF opposite the enclosure

Permissible temp.for environment in zone 0 6: -20 ... 60°C with patm 0.8 bar up to 1.1 bar zone 1 and higher: -25 ... 70°C

Connecting cables (by factory)

cable capacity: signal line/shield as well as signal line/signal line: 160 pF/mcable inductance: signal line/shield as well as signal line/signal line: 1 µH/m

5 only for 4...20mA, cable lenght max. 5m6 for optional stainless steel pipe the following designation is valid: "II 1 G Ex ia IIC T4" (zone 0)

LMK 458Technical Data

Page 63: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

63LMK 458Technical Data

LMK 458Hydrostatic Probe Technical Data

www.bdsensors.com

Wiring diagrams2-wire-system (current) 2-wire-system (current) with Pt 100

Pin configurationElectrical connection cable colours (IEC 60575)

Supply VS+Supply VS–

Option Pt 100 temperature element:Supply T+ (with Pt 100)Supply T– (with Pt 100)Supply T– (with Pt 100)

wh (white)bn (brown)

ye (yellow)gy (grey)pk (pink)

Shield gnye (green-yellow)Dimensions (in mm)

probe versions screw-in version

flange version

supply VS+

supply VS

supply T+supply T

supply T

VSP

Ioption Pt 100 temperature

stainless steel / CuNiFe prepared for mountingwith stainless steel pipestainless steel / CuNiFe

stainless steel / CuNiFe

stainless steel / CuNiFe

© 2

015

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

www.bdsensors.com

Page 64: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

64

www.bdsensors.com

LMK 458Ordering code

- - - - - - - - - -Pressure

7 6 57 6 87 6 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

1K9 consult

Design135

Diaphragm2C9 consult

Output1E9 consult

Seals13

FFKM 79 consult

Electrical connection49 consult

Accuracystandard 0.25 % 2option für PN ≥0.6 bar: 0.1 % 1

9 consultCable length

9 9 9Special version

0 0 0with temperature sensor Pt 100 0 1 3

5 0 29 9 9 consult

1 nominal pressure ranges absolute from 1 bar2 mounting accessories are not part of supply and have to be ordered separately3 min. permissible temperature from -15°C4 shielded cable with integrated air tube for atmospheric reference4 stainless steel pipe is not part of the supply

11.02.2015

customer

Screw-in version

Intrinsic safety 4 … 20 mA / 2-wire

Stainless steel 1.4404 (316L)

Flange version

customer

4

Probe

Copper-Nickel-alloy (CuNi10Fe1Mn)

Ordering code LMK 458

customer

in bar, gauge

EPDM

customer

© 2

015

BD|S

ENSO

RS

Gm

bH -

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

g at

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

Ceramics Al2O3 99.9%

in bar, absolute

Ceramics Al2O3 96%

customer

in m

TPE-U-cable

customer

FKM

customer

in mH2O

LMK 458

4 … 20 mA / 2-wire

5prepared for mounting with st. steel pipecustomer

3

1

2

standard

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 65: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

65

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 358Separable Stainless Steel Probe

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure

from 0 ... 40 cmH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 … 10 Vothers on request

Special characteristics

cable and probe separable diameter 39.5 mm especially for sewage, viscous

and pasty media

Optional versions

IS-protection zone 0 cable protection via corrugated pipe diaphragm 99.9 % AI2O3

different kinds of cable different kinds of elastomers

The separable stainless steel probe LMK 358 has been designed for level measurement in waste water, waste and higher viscosity media.Basic element is a capacitive ceramic sensor.

In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.

Preferred areas of use are

Waterground water level measurementrain spillway basin

Sewagewaste water treatmentwater recycling

Fuel / Oillevel monitoring in open tankswith low filling heightsfuel storagetank farms / biogas plants

PROBES

Page 66: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

66

LMK 358Stainless Steel Probe Technical Data

pressure and level

Input pressure range Nominal pressure gauge [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC

Option IS-protection 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC

Option 3-wire 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC

PerformanceAccuracy 1 standard: ≤ ± 0.35 % FSO

option: ≤ ± 0.25 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsTurn-on time 700 msecMean response time < 200 msec measuring rate 5/secMax. response time 380 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (Offset and Span)Thermal error ≤ ± 0.1 % FSO / 10 K

in compensated range 0 ... 70 °CPermissible temperaturesPermissible temperatures medium: -25 ... 125 °C

electronic / environment: -25 ... 125 °Cstorage: -40 ... 125 °C

Electrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Electrical connectionCable with sheath material 3 PVC (-5 … 70 °C) grey

PUR (-25 … 70 °C) black FEP4 (-25 … 70 °C) blackTPE (-25 … 125 °C) blue

3 shielded cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected

Materials (media wetted)Housing stainless steel 1.4404 (316L)Seals FKM

EPDMothers on request

Diaphragm standard: ceramics Al2O3 96 %option: ceramics Al2O3 99.9 %

Nose cone POMExplosion protection (only for 4 ... 20 mA / 2-wire)Approval DX14-LMK 358 IBExU05ATEX1070 X

Zone 0 5: II 1G Ex ia IIB T4 GaZone 20: II 1D Ex ia IIIC T85 °C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 27 nF, Li = 5 µHPermissible temperature -25 ... 70 °CConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 100 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

5 for optional stainless steel pipe following designation is valid: "II 1G Ex ia IIC T4 Ga" (zone 0)

MiscellaneousCurrent consumption max. 21 mA Weight approx. 650 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC

LMK 358Technical Data

www.bdsensors.com

Page 67: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

67LMK 358Technical Data

LMK 358Stainless Steel Probe Technical Data

ww.bdsensors.com

Wiring diagram2-wire-system (current) 3-wire-system (voltage) connector

Pin configuration

Electrical connection Binder series 723 6 (5-pin) cable colours (IEC 60575)2 - wire 3 - wire

Supply +Supply –

Signal + (only for 3-wire)

31-

341

wh (white)bn (brown)gn (green)

Shield 5 5 gnye(green-yellow)

6 in separated version

Dimensions (in mm)

separated version withcorrugated pipe

p

supply +

supply –

VS

I

supply +

signal +

VS

p

U

supply –

V

standard: optional:

www.bdsensors.com

Page 68: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

68

www.bdsensors.com

LMK 358Ordering code

- - - - - - - - - -Pressure

4 4 54 4 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1

100 10 1 0 0 29 9 9 9 consult

Housing19 consult

Diaphragm2C9 consult

Output13E9 consult

Seals139 consult

Electrical connection123

TPE-cable 49 consult

Accuracystandard 0.35 % 3option 0.25 % 2

9 consultCable length

in m 9 9 9Special version

0 0 0

9 9 9 consult

9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 stainless steel pipe is not part of the supply

15.04.2015

stainless steel corrugated pipecable protection with

1

1

Ordering code LMK 358

LMK 358

in bar

3

60©

201

5 B

D|S

EN

SO

RS

Gm

bH -

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat t

he ti

me

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

0

customer

EPDM

1

2standard

customer

PUR-cable

1

Stainless steel 1.4404 (316L)

customer

in mH2O

customer

customer

Ceramics Al2O3 99.9%customer

Ceramics Al2O3 96%

4 … 20 mA / 2-wire

FKM

customerwith pipe length in m

with stainless steel pipe

FEP-cable

Intrinsic safety 4 … 20 mA / 2-wire

customer

1

1PVC-cable

consult

0 … 10 V / 3-wire

prepared for mounting

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 69: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

69

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 808

Separable Plastic Probe

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 %

Nominal pressure

from 0 ... 1 mH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 20 mA / 0 ... 10 Vothers on request

Special characteristics

diameter 35 mm cable and sensor section separable

excellent linearity small thermal effect

Optional versions

SIL 2 (Safety Integrity Level)according to IEC 61508 / 61511

mounting accessories as screw fitting and terminal clamp of stainless steel

different kinds of cables and elastomers

customer specific versionse. g. special pressure ranges

The separable plastic probe is designed for level measurement of water, waste water as well as fu-els and oils. Basic element is a piezoresistive stainless steel sensor.

In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembl with a connector and can be changed easily.

Preferred areas of use are

Water / filtrated sewageground water level measurementstorm water systemsdrinking water systemwater treatment plants

Fuel / Oilfuel storagetank farmbiogas plantsprocess water recycling

PROBES

Page 70: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

70

LMP 808Plastic Probe Technical Data

pressure measurement

Input pressure rangeNominal pressure gauge [bar] 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100Overpressure [bar] 0.5 1 1 2 5 5 10 10 20 40 40Burst pressure ≥ [bar] 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Options 3-wire 3-wire: 0 ... 20 mA / VS = 14 ... 30 VDC0 ... 10 V / VS = 14 ... 30 VDC

PerformanceAccuracy standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO

nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSO

Permissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ωcurrent 3-wire: Rmax = 500 Ωvoltage 3-wire: Rmin = 10 kΩ

Influence effects supply: 0.05 % FSO / 10 Vload: 0.05 % FSO / kΩ

Long term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time < 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Nominal pressure PN [bar] < 0.40 ≥ 0.40Tolerance band [% FSO] ≤ ± 1 ≤ ± 0.75in compensated range [°C] 0 ... 50Permissible temperaturesPermissible temperatures medium: 0 ... 50 °C

storage: -10 ... 50 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (0 … 50 °C) grey

PUR (0 … 50 °C) blackFEP4 (0 … 50 °C) black

Cable protection standard: without cable protectionoptional: prepared for mounting of a PVC pipe with diameter 25 mm

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing PVC greySeals FKM

EPDM Diaphragm stainless steel 1.4435 (316L)Protection cap POMMiscellaneousOption SIL5 2 application according to IEC 61508 / IEC 61511Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

Current consumption signal output current: max. 25 mAsignal output voltage: max. 7 mA

Weight approx. 400 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/EC5 only for 4...20mA / 2-wire

LMP 808Technical Data

www.bdsensors.com

Page 71: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

71LMP 808Technical Data

LMP 808Plastic Probe Technical Data

www.bdsensors.com

Wiring diagrams2-wire-system (current) 3-wire-system (current / voltage) connector

Pin configurationElectrical connection Binder serie 723 6 (5-pin) cable colours (IEC 60575)

Supply + Supply – (only 2-wire)Supply – (only 3-wire)Signal + (only 3-wire)

3141

wh (white)bn (brown)bn (brown)gn (green)

Shield 5 gnye (green-yellow)6 in separated versionDimensions (in mm)

standard option

standard version separate version cable protection with PVC pipe without cable protection

p supply +

supply –

VS

I

supply +

signal +

VS

A/V

p

I/U

supply –

LMP808_E_011215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 72: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

72

www.bdsensors.com

LMP 808Ordering code

- - - - - - - - -Pressure

4 1 04 1 1

Input [mH2O] [bar]1.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2

9 9 9 9 consultHousing

A9 consult

Diaphragm19 consult

Output123

1S9 consult

Seals139 consult

Electrical connection1239 consult

Accuracystandard for PN ≥ 0.4 bar 0.35 % 3standard for PN < 0.4 bar 0.5 % 5option 1 for PN ≥ 0.4 bar 0.25 % 2

9 consultCable length

in m 9 9 9Special version

0 0 01 0 69 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 PVC pipe is not part of the supply

01.06.2013

1

1

1

PVC-cablePUR-cableFEP-cable

customer

PVCcustomer

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

Ordering code LMP 808

LMP 808

in bar

standard

in mH2O

customer

4 … 20 mA / 2-wire0 … 20 mA / 3-wire

Stainless steel 1.4435 (316L)

EPDMcustomer

0 … 10 V / 3-wireSIL2 4 … 20 mA / 2-wire

customer

customer

customer

prepared for mounting with PVC pipecustomer

2

FKM

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 73: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

73

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 806

Plastic Probe for Aggressive MediaCeramic Sensor

accuracy according toIEC 60770: 0.5 % FSO

Nominal pressure

from 0 ... 6 mH2O up to 0 ... 200 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 21 mm suitable for hydrostatic level

measurement e.g. 3/4" pipes

excellent linearity excellent long term stability

Optional versions

different cable materials customer specific versions

e.g. special pressure ranges

The LMK 806 with ceramic sensor and diameterfrom only 21 mm has been especially designed for the continuous level measurement at confined space conditions. Permissible media are waste water and different aggressive media.

Basic element of the plastic submersible probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and elastomer mate-rials are available in order to achieve maximum media compatibility.

Preferred areas of use are

Sewagewaste water treatmentwater recyclingdumpsite

Aggressive medialevel measurement in most of acids and lyes

PROBES

Page 74: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

74

LMK 806Plastic Probe Technical Data

pressure measurement

Input pressure rangeNominal pressure gauge [bar] 0.6 1 1.6 2.5 4 6 10 16 20Level [mH2O] 6 10 16 25 40 60 100 160 200Overpressure [bar] 2 2 4 4 10 10 20 40 40Burst pressure ≥ [bar] 4 4 5 5 12 12 25 50 50

Output signal / Supply2-wire 4 ... 20 mA / VS = 12 ... 32 VDC

PerformanceAccuracy1 ≤ ± 0.5 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩResponse time ≤ 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span) / Permissible temperaturesThermal error ≤ ± 0.4 % FSO / 10 K

in compensated range -25 ... 70 °CPermissible temperatures medium: -10 ... 50 °C

storage: -25 ... 50 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic protection emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (-5 … 50 °C) grey

PUR (-10 … 50 °C) blackFEP4 (-10 … 50 °C) black

3 shielded cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing PVCSeals FKMDiaphragm ceramics Al2O3 96 %Protection cap POMMiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

Current consumption max. 25 mAWeight approx. 100 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

wh (white)bn (brown)

Shield gnye (green-yellow)

psupply +

supply –

VS

I

LMK 806Technical Data

www.bdsensors.com

Page 75: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

75LMK 806Technical Data

LMK 806Plastic Probe Technical Data

www.bdsensors.com

Dimensions (in mm)

Accessories

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, steel, zinc plated Z100528Terminal clamp, stainless steel 1.4301 (304) Z100527

LMK806_E_011215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

tom

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 76: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

76

www.bdsensors.com

LMK 806Ordering code

- - - - - - - - -Pressure

3 7 53 7 6

Input [mH2O] [bar]6 0.60 6 0 0 0

10 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultHousing

A9 consult

Diaphragm29 consult

Output19 consult

Seals19 consult

Accuracy0.5 % 5

9 consultElectrical connection

1239 consult

Cable lengthin m 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

15.04.2014

1

PUR-cable

standard

customer

customer

FEP-cable

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

4 … 20 mA / 2-wire

customer

customer

customer

customerFKM

LMK 806

Ordering code LMK 806

1

1PVC-cable

customer

in mH2O

PVC

customer

Ceramics Al2O3 96%

in bar

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 77: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

77

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 807Plastic Probe for Aggressive Media

Ceramic Sensor

accuracy according to IEC 60770: 0.5 % FSO

Nominal pressure

from 0 ... 4 mH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mAothers on request

Special characteristics

diameter 35 mm excellent long term stability

easy handling

Optional versions

SIL 2 (Safety Integrity Level) according to IEC 61508 / IEC 61511

different kinds of cables and elastomers

customer specific versione. g. special pressure ranges

The plastic submersible probe LMK 807 is designed for continous level measurement for waste water or and different aggressive media.

Basic element of the plastic submersible probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and elastomer mate-rials are available in order to achieve maximum media compatibility.

Preferred areas of use are

Sewagewaste water treatmentwater recyclingdumpsite

Aggressive medialevel measurement in most of acids and lyes

PROBES

Page 78: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

78

LMK 807Plastic Submersible Probe Technical Data

pressure measurement

Input pressure rangeNominal pressure gauge [bar] 0.4 0.6 1 1.6 2.5 4 6 10Level [mH2O] 4 6 10 16 25 40 60 100Overpressure [bar] 1 2 2 4 4 10 10 20Burst pressure ≥ [bar] 2 4 4 5 5 12 12 25

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

PerformanceAccuracy 1 ≤ ± 0.5 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time < 10 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Thermal error ≤ ± 0.2 % FSO / 10 K

in compensated range -25 ... 70 °CPermissible temperaturesPermissible temperatures medium: 0 ... 50 °C

storage: -10 ... 50 °CElectrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (0 … 50 °C) grey

PUR (0 … 50 °C) blackFEP4 (0 … 50 °C) black

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing PVC greySeals FKM / EPDM / FFKMDiaphragm ceramics Al2O3 96 %MiscellaneousOption SIL 2 application according to IEC 61508 / IEC 61511Connecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

Current consumption max. 25 mA Weight approx. 200 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

wh (white)bn (brown)

Shield gnye (green-yellow)

p

supply +

supply –

VS

I

LMK 807Technical Data

www.bdsensors.com

Page 79: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

79LMK 807Technical Data

LMK 807Plastic Submersible Probe Technical Data

www.bdsensors.com

Dimensions (in mm)

Accessories

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, of steel, zinc plated Z100528Terminal clamp, of stainless steel 1.4301 (304) Z100527

Accessories

LMK807_E_011215

Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.deFax +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 80: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

80

www.bdsensors.com

LMK 807Ordering code

- - - - - - - - -Pressure

3 9 03 9 1

Input [mH2O] [bar]4.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2

9 9 9 9 consultHousing

A9 consult

Diaphragm29 consult

Output1

1S9 consult

Seals1379 consult

Accuracy59 consult

Electrical connection1239 consult

Cable lengthin m 9 9 9

Special version0 0 09 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

01.06.2013

Ceramics Al2O3 96%customer

customer

4 … 20 mA / 2-wire

in bar

customer

customer

customer

LMK 807

PVC-cable

Ordering code LMK 807

customer

PVC

customer

FEP-cable

0.5 %

PUR-cable1

1

1

FKM

customer

FFKMEPDM

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

standard

SIL2 4 … 20 mA / 2-wire

in mH2O

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 81: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

81

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 809Plastic Probe For Aggressive Media

High Purity Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure

from 0 ... 0.4 mH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 10 Vothers on request

Special characteristics

diameter 45 mm chemical resistance

high overpressure resistance

especially for tank level measurement of viscous and aggressive media

diaphragm 99.9 % AI2O3

housing material PP or PVDF

Optional versions

different kinds of cable and seal materials

prepared for mounting with pipe

The plastic submersible probe LMK 809 is de-signed for continous level measurement in waste water or in most of aggressive media. Basic ele-ment is a capacitiv ceramic sensor.

Basic element of the plastic probe is the flush mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and seal materials are available in order to achieve maximum media compatibility.

Preferred areas of use are

Sewagewaste water treatmentwater recyclingdumpsite

Aggressive medialevel measurement in most of acids and lyes

PROBES

Page 82: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

82

LMK 809Plastic Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC

Option 3-wire 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC

PerformanceAccuracy1 standard: ≤ ± 0.35 % FSO

option: ≤ ± 0.25 % FSOPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsTurn-on time 700 msecMean response time < 200 msec measuring rate: 5/secMax. response time 380 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Thermal error ≤ ± 0.1 % FSO / 10 K

in compensated range 0 ... 70 °CPermissible temperaturesPermissible temperatures medium: -25 … 100 °C

electronic / environment: -25 … 100 °Cstorage: -25 … 100 °C

Electrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PUR (-25 … 70 °C) black

FEP4 (-25 … 70 °C) blackTPE (-25 … 100 °C) blue

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing standard: PP

option: PVDF Seals FKM / EPDM / FFKMDiaphragm ceramics Al2O3 99.9 %MiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1µH/m

Current consumption max. 21 mA Weight approx. 320 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram2-wire-system (current) 3-wire-system (voltage)

Pin configurationElectrical connection cable colours (IEC 60575)

Supply +Supply –

Signal + (only for 3-wire)

wh (white)bn (brown)gn (green)

Shield gnye (green-yellow)

supply +

signal +

VS

p

U

supply –

V

p

supply +

supply –

VS

I

LMK 809Technical Data

www.bdsensors.com

Page 83: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

83LMK 809Technical Data

LMK 809Plastic Probe Technical Data

www.bdsensors.com LMK809_E_011215

Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax +49 (0) 92 35 / 98 11- 11 [email protected]

Dimensions (in mm)

standard option

prepared for mounting with pipe R1"

Accessories

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, steel, zinc plated Z100528Terminal clamp, stainless steel 1.4301 (304) Z100527

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 84: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

84

www.bdsensors.com

LMK 809Ordering code

- - - - - - - - -Pressure

3 9 53 9 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2

9 9 9 9 consultHousing

EB9 consult

DiaphragmC9 consult

Output139 consult

Seals1379 consult

Accuracystandard 0.35 % 3option 0.25 % 2

9 consultElectrical connection

23

TPE-cable 1 49 consult

Cable lengthin m 9 9 9

Special version0 0 06 1 0

customer 9 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference

01.06.2013

in bar

customer

customer

customerPVDF

customer

This

pric

e lis

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

FFKM

customerCeramics Al2O3 99.9%

pipe R1"

PUR-cable

FKMEPDM

FEP-cable1

0 … 10 V / 3-wire

Ordering code LMK 809

customer

LMK 809

1

PP

standard

4 … 20 mA / 2-wire

customer

in mH2O

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 85: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

85

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.deD - 95199 Thierstein Fax +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 858Separable Plastic Submersible Probe

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % FSO

Nominal pressure

from 0 ... 40 cmH2O up to 0 ... 100 mH2O

Output signals

2-wire: 4 ... 20 mA3-wire: 0 ... 10 Vothers on request

Special characteristics

diameter 45 mm cable and probe separable

chemical resistance

housing PVC

Optional versions

cable protection via PVC pipe diaphragm 99.9 % AI2O3

different kinds of cable different kinds of seal materials

The separable plastic submersible probe LMK 858 is designed for level measurement in most aggres-sive media. Usage in more viscous media as for example sludge is possible because of the semi-flush diaphragm.

In order to facilitate stock-keeping and mainten-ance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.

Preferred areas of use are

Sewagewaste water treatmentwater recyclingdumpsite

Aggressive medialevel measurement in most of acids and lyes

PROBES

Page 86: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

86

LMK 858Plastic Probe Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC option 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC

PerformanceAccuracy

standard:option:

IEC 60770 1

≤ ± 0.35 % FSO ≤ ± 0.25 % FSO

Permissible load Rmax = [(VS – VS min) / 0.02 A] ΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsTurn-on time 700 msecMean response time < 200 msec measuring rate 5/secMax. response time 380 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span)Thermal error ≤ ± 0.1 % FSO / 10 K

in compensated range 0 ... 50 °CPermissible temperaturesPermissible temperatures medium: -10 ... 50 °C

electronic / environment: -10 ... 50 °C storage: -10 ... 50 °C

Electrical protection 2

Short-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 613262 additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on requestElectrical connectionCable with sheath material 3 PVC (-5 … 50 °C) grey

PUR (-10 … 50 °C) blackFEP4 (-10 … 50 °C) black

Cable protection standard: without cable protectionoptional: prepared for mounting of a PVC pipe with diameter 25 mm

3 cable with integrated air tube for atmospheric pressure reference4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expectedMaterials (media wetted)Housing PVC greySeals FKM / EPDM / others on requestDiaphragm standard: ceramics Al2O3 96 %

option: ceramics Al2O3 99.9 % MiscellaneousConnecting cables (by factory)

cable capacitance: signal line/shield also signal line/signal line: 160 pF/mcable inductance: signal line/shield also signal line/signal line: 1 µH/m

Current consumption max. 25 mA Weight approx. 400 g (without cable)Ingress protection IP 68CE-conformity EMC Directive: 2004/108/ECWiring diagram

2-wire-system (current) 3-wire-system (voltage) connector

supply +

supply –

VS

p

I

A supply +

signal +

VS

p

U

supply –

V

LMK 858Technical Data

www.bdsensors.com

Page 87: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

87LMK 858Technical Data

LMK 858Plastic Probe Technical Data

ww.bdsensors.com LMK858_E_011215

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

Pin configurationElectrical connection Binder series 723 5 (5-pin) cable colours (IEC 60575)

2 - wire 3 - wireSupply +Supply –

Signal + (only for 3-wire)

31-

341

wh (white)bn (brown)gn (green)

Shield 5 5 gnye(green-yellow)

5 in separated versionDimensions (in mm)

standard separated version special version for cableprotection with PVC pipe

Accessoies

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mmMaterial standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)Weight approx. 160 gOrdering type Ordering codeTerminal clamp, steel, zinc plated Z100528Terminal clamp, stainless steel 1.4301 (304) Z100527 ©

201

4 BD

|SEN

SOR

S G

mbH

–Th

e sp

ecifi

catio

ns g

iven

in th

is d

ocum

ent r

epre

sent

the

stat

e of

eng

inee

ring

at th

e tim

e of

pub

lishi

ng. W

e re

serv

e th

e rig

ht to

mak

e m

odifi

catio

ns to

the

spec

ifica

tions

and

mat

eria

ls.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 88: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

88

www.bdsensors.com

LMK 858Ordering code

- - - - - - - - -Pressure

4 1 54 1 6

Input [mH2O] [bar]0.40 0.04 0 4 0 00.60 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2

9 9 9 9 consultHousing

A9 consult

Diaphragm2C9 consult

Output139 consult

Seals13 9 consult

Electrical connection1239 consult

Accuracystandard 0.35 % 3option 0.25 % 2

9 consultCable length

in m 9 9 9Special version

0 0 01 0 69 9 9 consult

1 cable with integrated air tube for atmospheric pressure reference2 PVC pipe is not part of the supply

01.06.2013

FKM

4 … 20 mA / 2-wire

customer

customerCeramics Al2O3 99.9%

customer

Ceramics Al2O3 96%

customer

in mH2O

LMK 858

PVC-cablePUR-cable

standardTh

is p

rice

list c

onta

ins

prod

uct s

peci

ficat

ion;

pro

perti

es a

re n

ot g

uara

ntee

d. D

etai

led

info

rmat

ion

abou

t opt

ions

are

def

ined

in th

e da

tash

eet.

Subj

ect t

o ch

ange

with

out n

otic

e.

in bar

1

customer2

Ordering code LMK 858

1

customer

prepared for mounting with PVC pipe

customer

customer

EPDM

0 … 10 V / 3-wire

1FEP-cable

PVC

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 89: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

89

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax +49 (0) 92 35 / 98 11- 11 [email protected]

LMP 331

Screw-In Transmitter

Stainless Steel Sensor

accuracy according to IEC 60770:standard: 0.35 % FSOoption: 0.25 % / 0.1 % FSO

Nominal pressure

from 0 ... 100 mbar up to 0 ... 40 bar

Output signals

2-wire: 4 ... 20 mA3-wire: 0 … 20 mA / 0 … 10 Vothers on request

Special characteristics

pressure port G 3/4" flush excellent accuracy small thermal effect excellent long term stability

Optional versions

accuracy 0.1% FSO IEC 60770 IS-version: Ex ia = intrinsically safe for

gases and dusts SIL 2 application according to

IEC 61508 / IEC 61511 different electrical connections customer specific versions

e. g. special pressure ranges

The screw-in transmitter LMP 331 has been designed for continuous level measurement and is characterized by an excellent performance and a robust construction. The modular construction al-lows the user the highest possible flexibility in the adaption of LMP 331.

Optional features like e.g. an intrinsically safe version or a functionally safe version (SIL 2) in-crease the advantages when launching and realiz-ing projects for plants and systems.

Preferred areas of use are

Plant and Machine Engineering

Energy Industry

Environmental Engineering(water – sewage – recycling)

SCREW-IN TRANSMITTERS

Page 90: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

90

LMP 331Stainless Steel Screw-In Transmitter Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.10 0.16 0.25 0.40 0.60 1 1.6 2.5 4 6 10 16 25 40Level [mH2O] 1 1.6 2.5 4 6 10 16 25 40 60 100 160 250 400Overpressure [bar] 0.5 1 1 2 5 5 10 10 20 40 40 80 80 105Burst pressure ≥ [bar] 1.5 1.5 1.5 3 7.5 7.5 15 15 25 50 50 120 120 210Vacuum resistance PN ≥ 1 bar: unlimited vacuum resistance

PN < 1 bar: on request

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Option IS-version 2-wire: 4 ... 20 mA / VS = 10 ... 28 VDC SIL-version: VS = 14 … 28 VDC

Options 3-wire 3-wire: 0 ... 20 mA / VS = 14 ... 30 VDC0 ... 10 V / VS = 14 ... 30 VDC

PerformanceAccuracy1 standard: nominal pressure < 0.4 bar: ≤ ± 0.5 % FSO

nominal pressure ≥ 0.4 bar: ≤ ± 0.35 % FSOoption 1: nominal pressure ≥ 0.4 bar: ≤ ± 0.25 % FSOoption 2: for all nominal pressures: ≤ ± 0.1 % FSO

Permissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ωcurrent 3-wire: Rmax = 500 Ωvoltage 3-wire: Rmin = 10 kΩ

Influence effects supply: 0.05 % FSO / 10 Vload: 0.05 % FSO / kΩ

Long term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time 2 2-Leiter: ≤ 10 msec

3-Leiter: ≤ 3 msec1 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)2 with optional accuracy 0,1 % FSO the response time is 200 msecThermal effects (Offset and Span)Nominal pressure PN [bar] ≤ 0.40 > 0.40Tolerance band [% FSO] ≤ ± 1 ≤ ± 0.75in compensated range [°C] 0 ... 70 -20 … 85Permissible temperaturesPermissible temperatures medium: -40 ... 125 °C

electronics / environment: -40 ... 85 °Cstorage: -40 ... 100 °C

Electrical protectionShort-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27Explosion protection (only for 4 ... 20 mA / 2-wire)ApprovalsDX19-LMP 331

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0nF, Li ≈ 0 µH,the supply connections have an inner capacity of max. 27 nF opposite the housing

Permissible temperature for medium

in zone 0: -20 ... 60 °C with patm 0.8 bar bis 1.1 barin zone 1 or higher: -20 ... 70 °C

Conneting cables(by factory)

cable capacitance: signal line/shield also signal line / signal line: 160 pF/mcable inductance: signal line /shield also signal line / signal line: 1 µH/m

MaterialsPressure port stainless steel 1.4404 (316L)Housing stainless steel 1.4404 (316L)Seals standard: FKM

option: EPDM others on request

Diaphragm stainless steel 1.4435 (316L)Media wetted parts pressure port, seals, diaphragm

LMP 331Technical Data

www.bdsensors.com

Page 91: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

91LMP 331Technical Data

LMP 331Stainless Steel Screw-In Transmitter Technical Data

www.bdsensors.com

MiscellaneousOptionally SIL 2 application according to IEC 61508 / IEC 61511Current consumption signal output current: max. 25 mA signal output voltage: max. 7 mAWeight approx. 200 gInstallation position any 3

Operational life > 100 x 106 cyclesCE-conformity EMC Directive: 2004/108/ECATEX Directive 94/9/EG3 Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight

deviation in the zero point for pressure ranges PN ≤ 1 bar.Pin configuration

Electrical connections ISO 4400 Binder 723(5-pin)

M12x1 / metal(4-pin) field housing cable colours (IEC

60575)Supply +Supply –

Signal + (only for 3-wire)

123

341

123

IN +IN –

OUT +

wh (white)bn (brown)gn (green)

Shield ground pin 5 4 gnye (green-yellow)Wiring diagrams

2-wire-system (current) 3-wire-system (current/voltage)

Electrical connections (dimensions in mm)

standard option

ISO 4400 Binder Series 723 5-pin M12x1 4-pin cable outlet with PVC cable compact field housing cable outlet, cable with(IP 65) (IP 67) (IP 67) (IP 67) 4 (IP 67) ventilation tube (IP 68)5

4 standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 ... 70 °C)5 different cable types and lengths available, permissible temperature depends on kind of cableMechanical connection (dimensions in mm)

standard standard for SIL- and SIL-Ex-version 6

G3/4" flush (DIN 3852) G3/4" flush (DIN 3852)with ISO 4400 with ISO 4400

6 not in combination with the accuracy 0.1%

supply +

signal +

VS

A/V

p

I / U

supply –

p supply +

supply –

VS

I

LMP331_E_011215

Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

015

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

give

n in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Page 92: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

92

www.bdsensors.com

LMP 331Ordering code

- - - - - - - -Pressure

4 3 04 3 1

Input [mH2O] [bar]1 0.10 1 0 0 0

1.6 0.16 1 6 0 02.5 0.25 2 5 0 04 0.40 4 0 0 06 0.60 6 0 0 0

10 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2400 40 4 0 0 2

9 9 9 9 consultPressure port

19 consult

Diaphragm19 consult

Output123E

1S

9 consultSeals

139 consult

Electrical connection1 0 02 0 0T A 0T R 0M 1 0

stainless steel 1.43059 9 9 consult

Accuracy0.35 % 3

0.5 % 50.25 % 2

0.1 % 19 consult

Special version0 0 09 9 9 consult

Prices EXW Thierstein, excluding package

1 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C), others on request2 cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable3 not in combination with SIL

05.03.2015

standardcustomer

standard for PN< 0.4 baroption 1 for PN ≥ 0.4 baroption 2

customer

customer

Male and female plug ISO 4400Male plug Binder series 723 (5-pin)

customer

FKMEPDM

SIL2 with Intrinsic safety ES4 … 20 mA / 2-wire

0 … 10 V / 3-wireIntrinsic safety 4 … 20 mA / 2-wire

SIL2 4 … 20 mA / 2-wire

customer

4 … 20 mA / 2-wire0 … 20 mA / 3-wire

customer

Stainless steel 1.4404 (316L)customer

Stainless steel 1.4435 (316L)

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

Ordering code LMP 331

LMP 331

standard for PN ≥ 0.4 bar

1

Cable outlet 2

in barin mH2O

Cable outlet with PVC cable

customer

Male plug M12x1 (4-pin) / metalCompact field housing

3

08 5

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 93: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

93

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 331

Screw-In Transmitter

Ceramic Sensor

accuracy according to IEC 60770:0.5 % FSO

Nominal pressure

from 0 ... 400 mbar up to 0 ... 60 bar

Output signals

2-wire: 4 ... 20 mA3-wire: 0 … 20 mA / 0 … 10 Vothers on request

Special characteristics

pressure port G 3/4" flush for pasty and impuritied media

pressure port PVDF for aggressive media

Optional versions

IS-version (only for 4 … 20mA / 2-wire): Ex ia = intrinsically safe for gases and dusts

SIL 2 application according to IEC 61508 / IEC 61511

customer specific versions

The screw-in transmitter LMK 331 has been especially designed for level and process mea-surement and is suitable for pressure measure-ment of liquids, oils and gases. Usage in more viscous or polluted media is possible because of the semi-flush pressure sensor.

For the usage in aggressive media we recom-mended the version with PVDF pressure port. Ad-ditional features like e.g. an intrinsically safe ver-sion or a functionally safe version (SIL 2) complete the range of possibilities.

Preferred areas of use are

Plant and Machine Engineering

Energy Industry

Environmental Engineering(water – sewage – recycling)

Medical Technology

SCREW-IN TRANSMITTERS

Page 94: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

94 LMK 331Technical Data

www.bdsensors.com

LMK 331Screw-In Transmitter Technical Data

pressure and level

Input pressure rangeNominal pressure gauge [bar] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 1 60 1

Level [mH2O] 4 6 10 16 25 40 60 100 160 250 400 600Overpressure [bar] 1 2 2 4 4 10 20 20 40 40 100 200Burst pressure [bar] 2 4 4 5 7,5 12 25 30 50 50 120 250Vacuum resistance [bar] PN ≥ 1 bar: unlimited vacuum resistance

PN < 1 bar: on request1 only possible with stainless steel pressure port

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC SIL-version: VS = 14 … 28 VDC

Option IS-protection 2 2-wire: 4 ... 20 mA / VS = 10 ... 28 VDC SIL-version: VS = 14 … 28 VDC

Optionen 3-wire 3-wire: 0 ... 20 mA / VS = 14 ... 30 VDC0 ... 10 V / VS = 14 ... 30 VDC

2 IS-protection not possible with plastic pressure portPerformanceAccuracy 3 ≤ ± 0.5 % FSOPermissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω

current 3-wire: Rmax = 500 Ωvoltage 3-wire: Rmin = 10 kΩ

Influence effects supply: 0.05 % FSO / 10 Vload: 0.05 % FSO / kΩ

Response time 2-wire: ≤ 10 msec3-wire: ≤ 3 msec

Long term stability ≤ ± 0,3 % FSO / year at reference conditions3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)Thermal effects (Offset and Span) / Permissible TemperaturesThermal error ≤ ± 0.2 % FSO / 10 Kin compensated range -25 ... 85 °CPermissible temperatures medium: -40 ... 125 °C

electronics / environment: -25 ... 85 °Cstorage: -40 ... 100 °C

Electrical protectionShort-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6Shock 500 g / 1 msec according to DIN EN 60068-2-27MaterialsPressure port / housing

standard:options for PN ≤ 25 bar:

pressure port housingstainless steel 1.4404 (316L)PVDF

stainless steel 1.4404 (316L)PVDF

Option compact field housing stainless steel 1.4305 with cable gland brass nickel plated others on requestSeals standard: FKM

options: EPDM others on requestDiaphragm ceramics Al2O3 96 % Media wetted parts pressure port, seals, diaphragmExplosion protection (only for 4 ... 20 mA / 2-wire)Approval DX19-LMK 331 only for stainless steel pressure port

IBExU 10 ATEX 1068 X / IECEx IBE 12.0027Xzone 0: II 1G Ex ia IIC T4 Gazone 20: II 1D Ex ia IIIC T 85°C Da

Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci ≈ 0 nF, Li ≈ 0 µH,the supply connections have an inner capacity of max. 27 nF to the housing

Permissible temperatures for environment

in Zone 0: -20 ... 60 °C with patm 0.8 bar up to 1.1 barin Zone 1 or higher: -25 ... 70 °C

Connecting cables (by factory)

cable capacitance: signal line/shield also signal line / signal line: 160 pF/mcable inductance: signal line /shield also signal line / signal line: 1 µH/m

MiscellaneousOption SIL 2 application according to IEC 61508 / IEC 61511Current consumption signal output current: max. 25 mA signal output voltage: max. 7 mAWeight approx. 150 gInstallation position anyOperational life > 100 x 106 pressure cyclesCE-conformity EMC Directive: 2004/108/ECATEX Directive 94/9/EG

Page 95: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

95LMK 331Technical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

LMK 331Screw-In Transmitter Technical Data

www.bdsensors.com

LMK331_E_011215

Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax +49 (0) 92 35 / 98 11- 11 [email protected]

Wiring diagrams2-wire-system (current) 3-wire-system (current / voltage)

Pin configurationElectrical connections ISO 4400 Binder 723

(5-pin)M12x1 / metal

(4-pin)cable colours (IEC 60575)

Supply +Supply –

Signal + (only for 3-wire)

123

341

123

wh (white)bn (brown)gn (green)

Shield ground contact 5 4 gnye (green-yellow)Electrical connections (dimensions in mm)

standard option

ISO 4400 Binder Series 723 5-pin M12x1 4-pin cable outlet with PVC cable compact field housing cable outlet, cable with(IP 65) (IP 67) (IP 67) (IP 67) 4 (IP 67) ventilation tube (IP 68)5

universal stainless steel housing 1.4404 with cable gland M20x1.5 (ordering code 880) and other versions on request

4 standard: 2 m PVC-cable without ventilation tube ( permissible temperature: -5 ... 70°C)5 different cable types and length available, permissible temperature depends on kind of cableMechanical connection (dimensions in mm)

standard standard for SIL- and SIL-Ex-version

G3/4" flush (DIN 3852) G3/4" flush (DIN 3852)with ISO 4400 with ISO 4400

p supply +

supply –

VS

I

supply +

signal +

VS

A/V

p

I / U

supply –

© 2

015

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

Page 96: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

96

www.bdsensors.com

LMK 331Ordering code

- - - - - - - - -Pressure

4 6 04 6 1

Input [mH2O] [bar]4.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2250 25 2 5 0 2400 40 4 0 0 2600 60 6 0 0 2

9 9 9 9 consultAnalogue output

12

0 … 10 V / 3-wire 3E1S

9 consultAccuracy

0.5 % 59 consult

Electrical connection1 0 02 0 0T A 0T R 0M 1 0

stainless steel 1.43059 9 9 consult

Mechanical connection

9 9 9 consultSeals

FKM 1EPDM 3

9 consultPressure port

1for PN ≤ 25 bar PVDF B

9 consultDiaphragm

29 consult

Special version0 0 09 9 9 consult

1 only possible for pressure port of stainless steel2 Ex-protection not possible with plastic pressure port3 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C)4 cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable5 min. permissible temperature -30 °C

24.08.2015

customer

5 0

Male plug M12x1 (4-pin) / metalcompact field housing 8

Cable outlet with PVC cable 3

Cable outlet

© 2

015

BD

|SE

NS

OR

S G

mbH

- Th

e sp

ecifi

catio

ns g

iven

in th

is d

ocum

ent r

epre

sent

the

stat

e of

eng

inee

ringa

t the

tim

e of

pub

lishi

ng. W

e re

serv

e th

e rig

ht to

mak

e m

odifi

catio

ns to

the

spec

ifica

tions

and

mat

eria

ls.

Ordering code LMK 331

LMK 331

gauge in bargauge in mH2O

customer

4 … 20 mA / 2-wire0 … 20 mA / 3-wire

Intrinsic safety 4 … 20 mA / 2-wire SIL2 4 … 20 mA / 2-wireSIL2 with Intrinsic safety ES4 … 20 mA / 2-wire

customer

customer

Male and female plug ISO 4400Male plug Binder series 723 (5-pin)

0 0flush sensor K

4

customer

customer

G3/4" DIN 3852 with

standardcustomer

Stainless steel 1.4404 (316L)

customer

Ceramics Al2O3 96%

5

2

1

1

2

customer

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 97: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

97

www.bdsensors.com

BD SENSORS GmbHBD-Sensors-Straße 1 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax +49 (0) 92 35 / 98 11- 11 [email protected]

LMK 351

Screw-in Transmitter

Ceramic Sensor

accuracy according to IEC 60770:standard: 0.35% FSOoption: 0.25% FSO

Nominal pressure

from 0 ... 40 mbar up to 0 ... 20 bar

Output signal

2-wire: 4 ... 20 mA3-wire: 0 … 20 mA / 0 … 10 Vothers on request

Product characteristics

pressure port PVDF-versionfor aggressive media

pressure port G 1 ½" forpasty and polluted media

Optional versions

IS-versionEx ia = intrinsically safe for gases and dust

diaphragm 99.9 % AI2O3

customer specific versions

The screw-in transmitter LMK 351 has been de-signed for measuring small system pressure and level measurement in container. The LMK 351 is based on an own-developed capacitive ceramic sensor element. Usage in viscous and pasty me-dia is possible because of the flush mounted sen-sor.

For the usage in aggressive media a pressure port in PVDF and the diaphragm in AI2O3 99.9 % is available. An intrinsically safe version complete the range of possibilities.

Preferred areas of use are

Plant and Machine Engineering

Environmental Engineering(water – sewage – recycling)

Preferred used for

Fuel and Oil

Viscous and Pasty Media

SCREW-IN TRANSMITTERS

Page 98: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

98

LMK 351Screw-in Transmitter Technical Data

pressure and level

Pressure rangesNominal pressure [bar] 0.04 0.06 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6 10 16 20Level [mH2O] 0.4 0.6 1 1.6 2.5 4 6 10 16 25 40 60 100 160 200Overpressure [bar] 2 2 4 4 6 6 8 8 15 25 25 35 35 45 45Low pressure [bar] -0.2 -0.3 -0.5 -1

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC

Option Ex-version 2-wire: 4 ... 20 mA / VS = 14 ... 28 VDC

Option 3-wire 3-wire: 0 ... 10 V / VS = 12.5 ... 32 VDC

PerformanceAccuracy1 standard: ≤ ± 0.35 % FSO

option for PN ≥ 0.6 bar: ≤ ± 0.25 % FSOPermissible load current 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω

voltage 3-wire: Rmin = 10 kΩInfluence effects supply: 0.05 % FSO / 10 V

load: 0.05 % FSO / kΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsTurn-on time 700 msecMean measuring time 5/secResponse time mean response time: ≤ 200 msec max. response time: 380 msec1 accuracy according to IEC 60770 - limit point adjustment (non-linearity, hysterisis, repeatability)Thermal effects (Offset and Span) / -Permissible temperaturesTolerance band ≤ ±0.1 % FSO / 10 K in compensated range - 20 ... 80 °CPermissible temperatures 2 medium: -40 ... 125 °C electronics / environment:-40 ... 85 °C storage: -40 ... 100 °C2 for pressure port of PVDF the minimum permissible temperature is -30 °CElectrical protectionShort-circuit protection permanentReverse polarity protection no damage, but also no functionElectromagnetic compatibility emission and immunity according to EN 61326Mechanical stabilityVibration 10 g RMS (20 ... 2000 Hz) according to DIN EN 60068-2-6Shock 100 g / 1 msec according to DIN EN 60068-2-27Materials (media wetted)Pressure port standard: stainless steel 1.4404 (316L) option: PVDFHousing standard: stainless steel 1.4404 (316L) option: PVDFSeals FKM -40 ... 125 °C

FFKM -15 ... 125 °CEPDM -40 ... 125 °C

Diaphragm standard: ceramics Al2O3 96 %options: ceramics Al2O3 99.9 %

Media wetted parts pressure port, seals, diaphragmIS-protection (only for 4 … 20 mA / 2-wire)Approval DX14-LMK 351 IBExU05ATEX1070 X

stainless steel-pressure port with male (connector):Zone 0: II 1G Ex ia IIC T4 GaZone 20: II 1D Ex ia IIIC T85 °C Da

plastic-pressure port with male (connector):Zone 0/1 3: II 1/2G Ex ia IIC T4 Ga/GbZone 20/21 4: II 1/2D Ex ia IIIC T85 °C Da/Db

Safety technicalmaximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 27 nF , Li = 5 µH

Max. permissible temperaturefor environment

in zone 0: -20 ... 60 °C for patm 0.8 bar up to 1.1 barzone 1 and higher: -25 ... 70 °C

Connecting cables (by factory)

capacity: signal line / shield also signal line / signal line: 160 pF/minductance: signal line / shield also signal line / signal line: 1 µH/m

3 The designation depends on the used pressure range. With nominal pressure ranges ≤ 60 mbar the designation is „2G“. 4 With nominal pressure ranges > 60 mbar and < 10 bar (see item 17 of the type-examination certificate) must be attended!MiscellaneousCurrent consumption signal output current: max. 21 mA signal output voltage: max. 5 mAWeight approx. 200 gInstallation position anyOperational life > 100 x 106 loading cyclesCE-conformity EMV-directive: 2004/108/ECATEX Directive 94/9/EC

LMK 351Technical Data

www.bdsensors.com

Page 99: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

99LMK 351Technical Data

LMK 351Screw-in Transmitter Technical Data

www.bdsensors.com

Wiring diagram2-wire-system (current) 3-wire-system (current/voltage)

Pin configuration

Electrical connection ISO 4400 Binder 723(5-pin)

M12x1(4-pin)

fieldhousing

cable colours (IEC 60575)

Supply +Supply –

Signal + (only for 3-wire)

123

341

123

IN +IN –

OUT +

wh (white)bn (brown)gn (green)

Shield ground pin 5 4 gnye(green-yellow)

Electrical connections (dimensions in mm)

standard option

ISO 4400 Binder Series 723 5-pin M12x1 4-pin cable outlet with PVC cable compact field housing cable outlet, cable with(IP 65) (IP 67) (IP 67) (IP 67) 4 (IP 67) ventilation tube (IP 68)5

4 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 ... 70 °C)5 different cable types and lengths available, permissible temperature depends on kind of cable

Dimensions (in mm)

material Astainless steel ca. 3

PVDF ca. 6

6 not possible in combination with compact field housing

G1 1/2" flush (DIN 3852)stainless steel

G1 1/2" flush (DIN 3852)PVDF 6

supply +

supply –

VS

p

I

Asupply +

signal +

VS

p

U

supply –

V

LMK 351_E_011215

Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Page 100: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

100

www.bdsensors.com

LMK 351Ordering code

- - - - - - - - -Pressure

4 7 04 7 1

Input [mH2O] [bar]0.4 0.04 0 4 0 00.6 0.06 0 6 0 01.0 0.10 1 0 0 01.6 0.16 1 6 0 02.5 0.25 2 5 0 04.0 0.40 4 0 0 06.0 0.60 6 0 0 010 1.0 1 0 0 116 1.6 1 6 0 125 2.5 2 5 0 140 4.0 4 0 0 160 6.0 6 0 0 1100 10 1 0 0 2160 16 1 6 0 2200 20 2 0 0 2

9 9 9 9 consultOutput

13E9 consult

Accuracystandard 0.35 % 3

0.25 % 29 consult

Electrical connection1 0 02 0 0T A 0T R 0M 1 08 5 09 9 9 consult

Mechanical connection

9 9 9 consultSeals

1379 consult

Pressure port1

3 B9 consult

Diaphragm2C9 consult

Special version0 0 09 9 9 consult

1 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C)2 cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable3 not possible in combination witn compact field housing; min. permissible temperature -30 °C

07.05.2014

compact field housing

Ceramics Al2O3 96%

Cable outlet

Intrinsic safety 4 … 20 mA / 2-wire

1

2

customer

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

Ordering code LMK 351

in mH2O

FKM

LMK 351

in bar

EPDM

0 … 10 V / 3-wire

customer

Male and female plug ISO 4400

Cable outlet with PVC- cable

4 … 20 mA / 2-wire

customer

customerFFKM

Male plug M12x1 (4-pin) / metal

Male plug Binder series 723 (5-pin)

Ceramics Al2O3 99.9%

standardcustomer

customer

Stainless steel 1.4404 (316L)PVDF

customer

customer

customer

G1 1/2" DIN 3852 withflush sensor M 0 0

option for PN ≥ 0.6 bar:

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 101: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

101

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

Technical Data

EP 500Pressure Transmitter

Special application: level measurement via air bubbling

Characteristics: capacitive ceramic sensor nominal pressure range from

0 ... 60 mbar up to 0 ... 20 bar output signal 4 ... 20 mA / 2-wire hat rail housing programming

via integrated interface

Input pressure rangeNominal pressure PN gauge [bar] 0.06 0.16 0.4 1 2 5 10 20Nominal pressure PN abs. [bar] on requestPermissible overpresure [bar] 2 4 6 8 15 25 35 40Permissible vacuum for PNgauge [bar] -0.2 -0.3 -0.5 -1

Output signal / SupplyStandard 2-wire: 4 ... 20 mA / VS = 9 ... 32 VDC; VS Nom. = 24 VDC

Current consumption max. 21 mA PerformanceAccuracy 1 IEC 60770 2: ≤ ± 0.2 % FSO BFSL: ≤ ± 0.1 % FSOTurn-on time 700 msecPermissible load Rmax = [(VS – VS min) / 0.02 A] ΩLong term stability ≤ ± 0.1 % FSO / year at reference conditionsResponse time (10 ... 90 %) 120 msec – without consideration of electronic dampingMeasuring rate 8/sec1 for nominal pressure ranges ≤0.4 bar the accuracy is calculated as follows: ≤ ± [0.2 + 0.04 x(nominal pressure range / adjusted range)] % FSO2 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal errors (Offset and Span)/ Permissible temperaturesThermal error ≤ ± (0.02 x nominal range / adjusted range) % FSO / 10 K

in compensated range 0 … 80°CPermissible temperatures medium: -40 ... 125°C electronics / environment / storage: -40 ... 85°C

SPECIAL VERSIONS

Page 102: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

102

EP 500Pressure Transmitter Technical Data

pressure and level

Electrical protectionShort-circuit protection permanentReverse polarity protection no damage, but also no functionElectrical connectionInput terminal clamps (3-pin)Communication connector M12x1 (8-pin), metalMaterialsPressure port standard: stainless steel 1.4301

on request: brassHousing version EP 500: PA6 (housing foot: PA66)

varsion EP 500 - 500: ABSSeals (media wetted) FKMDiaphragm ceramic Al2O3 96 % Media wetted parts pressure port, seals of sensor, diaphragmCategory of the environmentLloyd´s Register (LR) EMV1, EMV2, EMV3 number of certificate: 13/20056Germanischer Lloyd (GL) C, EMC1 number of certificate: 86 482 - 09 HHMiscellaneousIngress protection IP 00Function display green SMD-LED - lights by information flow through the transmitterInstallation position anyOperational life > 100 x 106 pressure cyclesWeight approx. 200 gAdjustability configuration via programming kit CIS 700 3; following configurations are possible:

- electronic damping: 0 ... 100 sec- offset: 0 ... 67 % FSO- turn down of span: max. 1:20- configuration of pressure unit- calibration via connected pressure reference

3 programming kit has to be ordered separately (software appropriate for Windows®95, 98, 2000, NT Version 4.0 or higher, and XP)

Pin configurationElectrical connections terminal clamps M12x1 (8-polig), metal

Supply +1Supply +2Supply –

TxRx

GNDNC

1-2----

-425671

Shield 3 3Wiring diagram

p supply +

supply –

VS

I+ -+ -

EP 500Technical Data

www.bdsensors.com

Page 103: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

103EP 500Technical Data

EP 500Pressure Transmitter Technical Data

EP500_E_151213

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

Dimensions (in mm)

standard EP 500:

G1/4"

option EP 500 - 500

optionally for PN ≤ 5 bar:

hose connection for flexible hoses Ø 4 mm

optionally for PN ≤ 5 bar:

G1/4" hose connection for flexible hoses Ø 4 mm

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 104: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

104

www.bdsensors.com

EP 500Ordering code

- - - - - - - -Pressure

U P 5U P 6 consult

Input [bar]0.06 0 6 0 00.16 1 6 0 00.4 4 0 0 01.0 1 0 0 12.0 2 0 0 15.0 5 0 0 110 1 0 0 220 2 0 0 2

9 9 9 9 consultOutput

19 consult

Accuracy0.2 % B

9 consultMechanical connection

Y 0 24 0 09 9 9 consult

Seal19 consult

Pressure port2

brass M consult9 consult

Diaphragm29 consult

Special version0 0 0

option 5 0 0 consultcustomer 9 9 9 consult

1 hose connection only up to 5 bar

Ordering code EP 500

standard

customer

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. Su

bjec

t to

chan

ge w

ithou

t not

ice.

ceramics Al2O3 96%customer

4 … 20 mA / 2-wirecustomer

G1/4" EN 837

EP 500

gaugeabsolute

customer

1

customer

hose connection Ø 4.5 mm

FKMcustomer

stainless steel 1.4301 (304)

customer

01.06.2013This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

Page 105: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

105

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

KL 1

Terminal Box

Aluminium

Product characteristics

aluminium die cast case

for connecting 2-wire submersible transmitters

integrated pressure balance item

2 signal lines

Optional versions

overvoltage protection with nominal discharge current of 10 kA

Pt 100 temperature sensor for submersible pressure transmitters with built in Pt 100 sensor

The terminal box KL 1 is intended for the pro-fessional electrical connection of 2-wire trans-mitters.

It offers integrated atmospheric pressure com-pensation. Optionally with overvoltage protection and Pt 100 temperatur sensor for BD|SENSORS devices.

The terminal box KL 1 is equipped with a pres-sure balance item for equalization of atmospher-ic reference, therefore a cable without ventilation tube can be used on the supply side.

Vertical terminal clamps enable easy connection of cables inside. The terminal box has to be mounted with two fastening screws.

ACCESSORIES

Page 106: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

106

KL 1Terminal Box Technical Data

pressure measurement

General specificationsNumber of signal lines 2-wire (4 ... 20 mA)Housing aluminium die cast case, grey powder-coatingIngress protection IP 66Cable entries cable gland M16x1.5 Polyamide, seals NBR, IP 68,

diameter range: standard 5 ... 10 mmothers on request

Atmospheric pressure compensation pressure balance item with PTFE filter

Terminal clamps vertical clamps for stranded and solid wires up to 2.5 mm2

Weight approx. 550 gOptional overvoltage protectionSeries resistance 10 Ω for each wireNominal discharge current 10 kA (8/20 µs)Max. rated current 30 mAOptional Pt 100 temperature sensor 1

Temperature range standard: 0 ... 70 °Coption: Tmin ... Tmax can be in range from -40 °C up to 400 °C

Connection temperature sensor 3-wireOutput signal / Supply 2-wire: 4 … 20 mA / VS = 12 … 34 VDC

Accuracy < 0.15 %Linearity < 0.1 %Thermal effects < 0.01 % / K1 only necessary if the transmitter is equipped with a Pt 100 temperature sensorWiring diagram

Dimensions (in mm)

The ground wires of all components have to be connected!VS *

* The supply VS has to be chosen according to needs of the used transmitter.

depth of housing: 58 mm

ground 4 mm²

Pt 100 transmitter (equipped only with Pt 100 version)

cable glandM16x1.5

pressure balance item

mounting hole

equipped only with Pt 100 version

GND VS− VS+ T− T− T+ GND VT+VT−VP+VP−

pressure signalsupply +

supply – temp.-signalsupply +

supply –

KL1_E_010613

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

KL 1Technical Data

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

www.bdsensors.com

Page 107: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

107

- -Version

1 0 01 0 11 T 01 T 1

Special version0 0 09 9 9 consult

1 only necessary if the submersible transmitter is equipped with a Pt 100 temperature sensor

01.06.2013

thermo element Pt 1001

customer

over voltage protection

thermo element Pt 100 and over voltage protection

standard

This

dok

umen

ts c

onta

ins

prod

uct s

peci

ficat

ion;

pro

perti

es a

re n

ot g

uara

ntee

d. D

etai

led

info

rmat

ion

abou

t opt

ions

are

def

ined

in th

e da

tash

eet.

Subj

ect t

o ch

ange

with

out n

otic

e.

Ordering code KL 1

standard

KL 1 - ZB.601

KL 1Ordering code

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

www.bdsensors.com

Page 108: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

108

www.bdsensors.comBD SENSORS GmbHBD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 [email protected]

KL 2

Terminal Box

Plastics

Product characteristics

cost-efficient ABS case

for connecting 2-wire submersible transmitters

integrated pressure balance item

2 signal lines

Optional versions

Version for two independent 2 wire circuits

overvoltage protection

HART® connection

The terminal box KL 2 is intended for the pro-fessional electrical connection of submersible level transmitters. Thus, it is a cost-effective alternative to our well proven aluminium terminal box KL 1.

A pressure balance item is responsible for the compensation of atmospheric pressure varia-tions. On the supply side a cable without ventila-tion tube can be used.

Vertical terminal clamps enable easy connection of cables inside the case.

The KL 2 with optional overvoltage protection is additionally equipped with surge arresters with a nominal discharge current of 10 kA.

As a further option the KL 2 is available with a HART® connection.

ACCESSORIES

Page 109: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

109

www.bdsensors.com

KL 2Technical Data

KL 2Terminal Box Technical Data

pressure measurement

General specificationsNumber of signal lines 2-wire (4 ... 20 mA)Housing material plastic ABS, greyIngress protection IP 66Cable entries cable gland M16x1.5 Polyamide, seals NBR, IP 68,

diameter range: standard 5 ... 10 mmothers on request

Atmospheric pressure compensation pressure balance item with PTFE filter

Terminal clamps vertical clamps for stranded and solid wires up to 2.5 mm2

Weight approx. 220 gOptional overvoltage protectionSeries resistance 10 Ω for each wireNominal discharge current 10 kA (8/20 µs)Max. rated current 30 mAOptional HART® connectionConnections terminal clamp connectionWiring diagram

Version with 2 channels, eg. LMK 307T, LMP 307T

* The supply VS has to be chosen according to needs of the used transmitter.The ground wires of all components have to be connected!

Dimensions (in mm)

standard version with 2 channels

Version for two independent 2 wire circuits and over voltage protection, eg. for LMK 307T, LMP 307T

HART® is a registered trade mark of HART Communication Foundation

KL2_E_180814

Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.comFax: +49 (0) 92 35 / 98 11- 11 [email protected]

© 2

014

BD|S

ENSO

RS

Gm

bH–

The

spec

ifica

tions

giv

en in

this

doc

umen

t rep

rese

nt th

e st

ate

of e

ngin

eerin

gat

the

time

of p

ublis

hing

. We

rese

rve

the

right

to m

ake

mod

ifica

tions

to th

e sp

ecifi

catio

ns a

nd m

ater

ials

.

depth of housing:55 mm

Mounting hole ∅ 4.2

equipped only with HART®version

Cable gland M16x1.5

Pressure balance item

IN+ IN- GND

HART

HA

Cable gland M16x1.5

Pressure balance item

supply –

supply +

InterfaceHART RS 232 C PC

VS *

This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Page 110: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

110 KL 2Ordering code

- -Version

2 0 02 0 12 2 02 2 12 H 0

Special version0 0 09 9 9 consult

1 Version for 2 independent 2 wire circuits

HART® is a registered trade mark of HART Communication Foundation

18.08.2014

standard

standard

version with 2 channels

and over voltage protectionHART® communication interface

Ordering code KL 2

2 H 1

This

dok

umen

t con

tain

s pr

oduc

t spe

cific

atio

n; p

rope

rties

are

not

gua

rant

eed.

Det

aile

d in

form

atio

n ab

out o

ptio

ns a

re d

efin

ed in

the

data

shee

t. S

ubje

ct to

cha

nge

with

out n

otic

e.

customer

KL 2 - ZB.601

HART® communication interfaceversion with 2 channels and over voltage protection

1

1

over voltage protection

- -Version

2 0 02 0 12 2 02 2 12 H 0

Special version0 0 09 9 9 consult

1 Version for 2 independent 2 wire circuits

HART® is a registered trade mark of HART Communication Foundation

18.08.2014

standard

standard

version with 2 channels

and over voltage protectionHART® communication interface

Ordering code KL 2

2 H 1

This

doku

ment

conta

ins pr

oduc

t spe

cifica

tion;

prope

rties a

re no

t gua

rantee

d. De

tailed

infor

matio

n abo

ut op

tions

are d

efine

d in t

he da

tashe

et. S

ubjec

t to ch

ange

with

out n

otice

.

customer

KL 2 - ZB.601

HART® communication interfaceversion with 2 channels and over voltage protection

1

1

over voltage protection

This document contains product specifications; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.

www.bdsensors.com

Page 111: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

111ACCESSORIES

BD SENSORS GmbHBD-Sensors-Straße 1 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.comD - 95199 Thierstein Fax +49 (0) 92 35 / 98 11- 11 [email protected]

Mounting flange with cable glandTechnical data

Suitable for all probes

Flange material stainless steel 1.4404 (316L)

Material of cable glandstandard: brass, nickel platedon request: stainless steel 1.4305; plastic

Seal insert material: TPE (ingress protection IP 68)

Hole pattern according to DIN 2507

Version Size (in mm) Weight

DN25 / PN40 D = 115, k = 85, b = 18, n = 4, d= 14 1.4 kg

DN50 / PN40 D = 165, k = 125, b = 20, n = 4, d= 18 3.2 kg

DN80 / PN16 D = 200, k = 160, b = 20, n = 8, d= 18 4.8 kg

Ordering type Ordering code

DN25 / PN40 with cable gland brass, nickel plated ZMF2540

DN50 / PN40 with cable gland brass, nickel plated ZMF5040

DN80 / PN16 with cable gland brass, nickel plated ZMF8016

Terminal clampTechnical DataSuitable for all probes with cable ∅ 5.5 ... 10.5 mm

Material standard: steel, zinc platedoptionally: stainless steel 1.4301

Weight approx. 160 g

Ordering type Ordering code

Terminal clamp, steel, zinc plated Z100528

Terminal clamp, stainless steel 1.4301 Z100527

probe flangeTechnical dataSuitable for LMK 382, LMK 382H, LMK 458, LMK 458H

Flange material stainless steel 1.4404 (316L)

Hole pattern according to DIN 2507

Version Size (in mm) Weight

DN25 / PN40 D = 115, k = 85, b = 18, n = 4, d= 14 1.2 kg

DN50 / PN40 D = 165, k = 125, b = 20, n = 4, d= 18 2.6 kg

DN80 / PN16 D = 200, k = 160, b = 20, n = 8, d= 18 4.1 kg

Ordering type Ordering codeTransmitter flange DN25 / PN40 ZSF2540

Transmitter flange DN50 / PN40 ZSF5040

Transmitter flange DN80 / PN16 ZSF8016

Accessories

cable gland M16x1.5 with seal insert (for cable-∅ 4 ... 11 mm)

www.bdsensors.com

Page 112: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

112

www.bdsensors.com

ACCESSORIES

Description Display Input OutputHousing Dimensions

(B x H x T) in mmInterface

PA 430Plug-on Display self poweredwith Contactsand Ex-approval

4-digit LED-display 4 x 7 mm, rotatable

4 ... 20 mA, 0 ... 10 V0 / 1 / 2 PNP-outputs4 ... 20 mA, 0 ... 10 V

plastic, rotatable

47 x 47 x 68_

PA 440Field Displaywith Contactsand Ex-approval

4-digit LED-display 4 x 10 mm4-digit LCD-display 4 x 18 mm

4 ... 20 mA0 / 1 / 2 PNP- outputs4 ... 20 mA

plastic120 x 80 x 57aluminium125 x 80 x 57

_

PA 450Field Displayfor Difference Formation

4-digit LED-display 4 x 10 mm 2 inputs: 4 ... 20 mA0 / 1 / 2 PNP- outputs4 ... 20 mA

plastic120 x 80 x 57

_

CIT 200 Process Display 4-digit LED-display 4 x 13 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

front panel72 x 36 x77 (95)

RS 485 Modbus RTU

CIT 250Process Displaywith Contacts

4-digit LED-display 4 x 13 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

0 / 1 / 2 relay- outputsfront panel72 x 36 x 77

RS 485 Modbus RTU

CIT 300Process Displaywith Contacts andAnalogue Output

4-digit LED-display 4 x 20 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

0 / 2 / 4 relay- outputs0/4 ... 20 mA

front panel96 x 48 x 98

RS 485 Modbus RTU

CIT 350Process Displaywith Bargraph, Contacts and Analogue Output

4-digit LED-display 4 x 9 mm+ 20-segment-Bargraph

0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V

0 / 2 / 4 relay- outputs0/4 ... 20 mA

front panel48 x 96 x 98

RS 485 Modbus RTU

CIT 400Process Displaywith Contacts, Analogue Outputand Ex-approval

4-digit LED-display 4 x 10 mm 4 ... 20 mA2 / 4 relay- outputs0/4 ... 20 mA

front panel72 x 72 x 110hat rail 70 x 75 x 110

_

CIT 600 Multichannel Process Display (LCD) graphic LC-display 128 x 64 pixel2 / 4 / 8 inputs: 0/4 ... 20 mA,PT100 / PT500 / PT1000

2 OC- outputsfront panel96 x 96 x 100

RS 485 Modbus RTU

CIT 650Multichannel Process Display (LCD)with Datalogger

graphic LC-display 128 x 64 pixel1 / 4 / 8 inputs: 0/4 ... 20 mA,PT100 / PT500 / PT1000

2 OC- outputsfront panel96 x 96 x 100

RS 485 Modbus RTUUSB-Host Port

CIT 700Mulitchannel Process Display (TFT)with Contacts, Analogue Outputs and Datalogger

graphic 3,5“ TFT- monitor, touchscreen

max. 48 inputs: 0 ... 20 mA, 0 ... 10 Vmax. 12 inputs: PT 100 / PT 500 / PT 1000 (Ω)max. 24 inputs: thermocouple (mV)

max. 16 relay- outputs,max. 24 SSR-ouputs,max. 8 outputs 4 … 20 mA

front panel96 x 96 x 100

RS 485 Modbus RTU,RS 232, Ethernet (Modbus TCP, Java Applets)USB Host Port

CIT 750Mulitchannel Process Display (TFT)with Contacts, Analogue Outputs and Datalogger

graphic 5,7“ TFT- monitor, touchscreen

max. 72 inputs: 0 ... 20 mA, 0 ... 10 Vmax. 18 inputs: PT 100 / PT 500 / PT 1000 (Ω)max. 36 inputs: thermocouple (mV)

max. 36 relay- outputs,max. 72 SSR-outputs,max. 24 outputs 4 … 20 mA

front panel144 x 144 x 100

RS 485 Modbus RTU,RS 232, Ethernet (Modbus TCP, Java Applets)USB Host Port

Page 113: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

113

www.bdsensors.com

ACCESSORIES

Description Display Input OutputHousing Dimensions

(B x H x T) in mmInterface

PA 430Plug-on Display self poweredwith Contactsand Ex-approval

4-digit LED-display 4 x 7 mm, rotatable

4 ... 20 mA, 0 ... 10 V0 / 1 / 2 PNP-outputs4 ... 20 mA, 0 ... 10 V

plastic, rotatable

47 x 47 x 68_

PA 440Field Displaywith Contactsand Ex-approval

4-digit LED-display 4 x 10 mm4-digit LCD-display 4 x 18 mm

4 ... 20 mA0 / 1 / 2 PNP- outputs4 ... 20 mA

plastic120 x 80 x 57aluminium125 x 80 x 57

_

PA 450Field Displayfor Difference Formation

4-digit LED-display 4 x 10 mm 2 inputs: 4 ... 20 mA0 / 1 / 2 PNP- outputs4 ... 20 mA

plastic120 x 80 x 57

_

CIT 200 Process Display 4-digit LED-display 4 x 13 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

front panel72 x 36 x77 (95)

RS 485 Modbus RTU

CIT 250Process Displaywith Contacts

4-digit LED-display 4 x 13 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

0 / 1 / 2 relay- outputsfront panel72 x 36 x 77

RS 485 Modbus RTU

CIT 300Process Displaywith Contacts andAnalogue Output

4-digit LED-display 4 x 20 mm0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V,PT100 / PT500 / PT1000

0 / 2 / 4 relay- outputs0/4 ... 20 mA

front panel96 x 48 x 98

RS 485 Modbus RTU

CIT 350Process Displaywith Bargraph, Contacts and Analogue Output

4-digit LED-display 4 x 9 mm+ 20-segment-Bargraph

0/4 ... 20 mA, 0/1 ... 5 V,0/2 ... 10 V

0 / 2 / 4 relay- outputs0/4 ... 20 mA

front panel48 x 96 x 98

RS 485 Modbus RTU

CIT 400Process Displaywith Contacts, Analogue Outputand Ex-approval

4-digit LED-display 4 x 10 mm 4 ... 20 mA2 / 4 relay- outputs0/4 ... 20 mA

front panel72 x 72 x 110hat rail 70 x 75 x 110

_

CIT 600 Multichannel Process Display (LCD) graphic LC-display 128 x 64 pixel2 / 4 / 8 inputs: 0/4 ... 20 mA,PT100 / PT500 / PT1000

2 OC- outputsfront panel96 x 96 x 100

RS 485 Modbus RTU

CIT 650Multichannel Process Display (LCD)with Datalogger

graphic LC-display 128 x 64 pixel1 / 4 / 8 inputs: 0/4 ... 20 mA,PT100 / PT500 / PT1000

2 OC- outputsfront panel96 x 96 x 100

RS 485 Modbus RTUUSB-Host Port

CIT 700Mulitchannel Process Display (TFT)with Contacts, Analogue Outputs and Datalogger

graphic 3,5“ TFT- monitor, touchscreen

max. 48 inputs: 0 ... 20 mA, 0 ... 10 Vmax. 12 inputs: PT 100 / PT 500 / PT 1000 (Ω)max. 24 inputs: thermocouple (mV)

max. 16 relay- outputs,max. 24 SSR-ouputs,max. 8 outputs 4 … 20 mA

front panel96 x 96 x 100

RS 485 Modbus RTU,RS 232, Ethernet (Modbus TCP, Java Applets)USB Host Port

CIT 750Mulitchannel Process Display (TFT)with Contacts, Analogue Outputs and Datalogger

graphic 5,7“ TFT- monitor, touchscreen

max. 72 inputs: 0 ... 20 mA, 0 ... 10 Vmax. 18 inputs: PT 100 / PT 500 / PT 1000 (Ω)max. 36 inputs: thermocouple (mV)

max. 36 relay- outputs,max. 72 SSR-outputs,max. 24 outputs 4 … 20 mA

front panel144 x 144 x 100

RS 485 Modbus RTU,RS 232, Ethernet (Modbus TCP, Java Applets)USB Host Port

Page 114: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

114 4 ADVANTAGES

PRICE / PERFORMANCE

pressure measurement at the highest level

The concentration on electronic pressure transmitter has led

to extraordinary efficiency and economical pricing.

BD|SENSORS is certain to be one of the most economical

suppliers on the world market, given equal technical and

commercial conditions.

RELIABILITY

projectable delivery times and strict observance of deadlines

Short delivery times and firm deadlines, even for special

designs, make BD|SENSORS a reliable partner for our

customers.

BD|SENSORS reduces the level of your stock-keeping and

increases your profitability.

FLEXIBILITY

We have special solutions for your individual requirement.

We solve your problem in industrial pressure measurement

quickly and economically, not only with large-scale

production lines, but also for smaller requirements.

BD|SENSORS is especially flexible when technical support

and quick assistance are required in service case as well

as for rush orders.

COMPETENCE

Industrial pressure measurement technology from 0.1 mbar up to 6000 bar

> pressure transmitters, electronic pressure switches or hydrostatic level probes

> OEM or high-end products

> standard products or customized solutions

BD|SENSORS has the right pressure measuring device

at the right price.

www.bdsensors.com

Page 115: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

115

INDUSTRIES

plant and machine engineering

chemical and biochemical industry

energy industry

renewable energy

semiconducter industry /

cleanroom technology

HVAC

hydraulics

refrigeration

calibration techniques

laboratory techniques

medical technology

food and beverage

vehicles and mobile hydraulics

oil and gas industry

pharmaceutical industry

marine / shipbuilding / offshore

heavy industry

environmental industry

packaging and paper industry

MEDIA

sewage

aggressive media

colours

gases

fuels and oils

pasty and viscous media

oxygen

water

Page 116: PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN … · PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS. 2 PRESSURE AT THE HIGHEST LEVEL „Successful medium-sized companies

DISTRIBUTION WORLDWIDE

HEADQUARTERS OF BD|SENSORS GROUP

BD | SENSORS GmbH

BD-Sensors-Straße 1

95199 THIERSTEIN

GERMANY

Tel.: +49 9235 9811-0

Fax: +49 9235 9811-11

www.bdsensors.de

[email protected]

DISTRIBUTION EASTERN EUROPE

BD | SENSORS s.r.o.

Hradišt’ská 817

687 08 BUCHLOVICE

CZECH REPUBLIC

Tel.: +420 572 411-011

Fax: +420 572 411-497

www.bdsensors.cz

[email protected]

Status 01/2016 Technical changes reserved.