product catalogue for operation spares

214
PRODUCT CATALOGUE FOR OPERATION SPARES TELECOMMUNICATION SYSTEM Vendor Omega Integration Pte Ltd PO Number 6500009213 Ref Doc MM-ZTK-1A-ZPQ-T001-LIS-0006 Rev 4 Incoterm DAP Ranong

Upload: vivianpmp

Post on 26-Oct-2015

591 views

Category:

Documents


6 download

DESCRIPTION

Product Catalogue for Operation Spares

TRANSCRIPT

Page 1: Product Catalogue for Operation Spares

PRODUCT CATALOGUE FOR

OPERATION SPARES

TELECOMMUNICATION SYSTEM

Vendor Omega Integration Pte Ltd

PO Number 6500009213

Ref Doc MM-ZTK-1A-ZPQ-T001-LIS-0006 Rev 4

Incoterm DAP Ranong

Page 2: Product Catalogue for Operation Spares

Table of Contents1.0 DNH B-650(T)2.0 DNH B-406(T)3.0 DNH HS-8EExmN(T)4.0 DNH DSP-15EExmN(T)5.0 MEDC XB156.0 ELEMEC PLUS7.0 CLASS D AUDIO AMPLIFIER8.0 RW2000 B-series9.0 RW-7100 IDU-E Series10.0 ME3400E Switch11.0 Nexans N423.540N12.0 AUTELDAC 413.0 VoIP AUTELDAC 414.0 MEDC DB315.0 AVAYA 160816.0 AVAYA 161617.0 MMC VG504xM18.0 SG12-06B2A Grounding kit19.0 Tetra BHR21 IS20.0 Etelm Tetra Amplifier21.0 Pelco KBD500022.0 Pelco IPSXM3023.0 SAILOR_630124.0 Sailor 6080 PSU25.0 Sailor N163S26.0 Sailor SP353027.0 Sailor 6080 PSU28.0 SAC SA25 50 10029.0 SAC PC1000C30.0 PACIFIC 6W SPLITTER31.0 ENTERTAINMENT SYSTEM32.0 DTRS SYSTEM

3579

1114202332345457606366697276798183869398

102104165169172174176206

Page 3: Product Catalogue for Operation Spares

1.0 DNH B-650(T)

Page 4: Product Catalogue for Operation Spares

DNH AS Phone................... + 47 35 98 56 00 Fax………............. + 47 35 98 56 10 E-mail...………............ [email protected] Web-Site…………….. www.dnh.no

DNH WW Ltd Phone……. + 44 1908 275 000 Fax.............+ 44 1908 275 100 E-mail…[email protected]

DNH Speakers Inc Phone........... + 1 484 494 5790 Fax…........... .+ 1 484 494 5793 [email protected]

DNH GmbH Phone… + 49 040 6569 30-0 Fax....... + 49 040 6569 30-30 E-mail...........…. [email protected] ISO 9001 CERTIFIED

DNH reserves the right to alter specifications without notice

HEAD OFFICE, NORWAY ENGLAND GERMANY USA

T:\Dataark\DOC-format\CEILING\CeilingPlastic\B650T.doc Rev. 11.12.2012

B-650(T)

Sound pressure levels at 1W/1m w/P-6/15B Specifications Material / Color ABS grille, Polystyrene box / White Mounting 3 screws Termination Spring clamps Weight w/ transformer 1,1 kg IP-rating 42 Max. / min. amb. temp 90°C / -20°C Rated / max. power 6 W / 15 W SPL 1W/1m 90 dB SPL rated power 97 dB Effective freq. range 120 – 18000 Hz Dispersion (-6dB) 1kHz / 4kHz 130° / 50° Directivity factor, Q Options Impedances, colors, labels

Installation, Operation and Maintenance Procedures

Install box by turning 3 screws clockwise and the 3 hooks will keep loudspeaker in position. Lead cable in to the box, connect to terminal (70V or 100V) and select required tapping in to the transformer. Screw loudspeaker grill clockwise into fixed position For optimum performance, always use the correct voltage / power and operate within the frequency limits as

stated. Do not open loudspeaker when energized. This loudspeaker is supplied with a 2 year warranty against defective workmanship.

70/100 Volt combined transformer

Primary connections White : Green 70 V White : Red 100 V

Secondary nominal tappings

C : 6W 6,0 WC : 3W 3,0 WC : 1,5W 1,5 WC : 0,5W 0,5 W

Page 5: Product Catalogue for Operation Spares

2.0 DNH B-406(T)

Page 6: Product Catalogue for Operation Spares

DNH AS Phone................... + 47 35 98 56 00 Fax………............. + 47 35 98 56 10 E-mail...………............ [email protected] Web-Site…………….. www.dnh.no

DNH WW Ltd Phone……. + 44 1908 275 000 Fax.............+ 44 1908 275 100 E-mail…[email protected]

DNH Speakers Inc Phone........... + 1 484 494 5790 Fax…........... .+ 1 484 494 5793 [email protected]

DNH GmbH Phone… + 49 040 6569 30-0 Fax....... + 49 040 6569 30-30 E-mail...........…. [email protected] ISO 9001 CERTIFIED

DNH reserves the right to alter specifications without notice

HEAD OFFICE, NORWAY ENGLAND GERMANY USA

http://companyweb/teknisk/Dataark/Cabinet/B-406(T).doc Rev. 15.03.2013

B-406(T)

Installation, Operation and Maintenance Procedures

Remove backplate by bending back two sides of cabinet. Screw the backplate to wall or ceiling. Lead cable through a cable entry, connect to terminal (70V or 100V) and select required tapping in to the

transformer. Clip on the cabinet into the backplate. For optimum performance, always use the correct voltage / power and operate within the frequency limits as

stated. Do not open loudspeaker when energized. This loudspeaker is supplied with a 2 year warranty against defective workmanship.

Sound pressure levels at 1W/1m w/P6-15B Specifications Material / Color ABS / Light grey Mounting Screws and keyhole Termination Spring clamps Weight w/transformer 1,1 kg IP-rating Max. / min. amb. temp 90°C / -20°C Rated / max. power 6 W / 8 W SPL 1W/1m 92 dB SPL rated power 98 dB Effective freq. range 230 – 20000 Hz Dispersion (-6dB) 1kHz / 4kHz 170° / 50° Directivity factor, Q Options Impedances, colors, labels

70/100 Volt combined transformer

Primary connections White : Green 70 V White : Red 100 V

Secondary nominal tappings

C : 6 6,0 WC : 3 3,0 WC : 1,5 1,5 WC : 0,5 0,5 W

Page 7: Product Catalogue for Operation Spares

3.0 DNH HS-8EExmN(T)

Page 8: Product Catalogue for Operation Spares

DNH AS Phone................... + 47 35 98 56 00 Fax………............. + 47 35 98 56 10 E-mail...………............ [email protected] Web-Site…………….. www.dnh.no

DNH WW Ltd Phone……. + 44 1908 275 000 Fax.............+ 44 1908 275 100 E-mail…[email protected]

DNH Speakers Inc Phone........... + 1 484 494 5790 Fax…........... .+ 1 484 494 5793 [email protected]

DNH GmbH Phone… + 49 040 6569 30-0 Fax....... + 49 040 6569 30-30 E-mail...........…. [email protected] ISO 9001 CERTIFIED

DNH reserves the right to alter specifications without notice

HEAD OFFICE, NORWAY ENGLAND GERMANY USA

http://companyweb/teknisk/Dataark/Ex_EEx/Aluminum horns/HS-8EExmN(T) doc

Rev. 16.05.2013

HS-8EExmNT

Installation, Operation and Maintenance Procedures Unscrew lid, lead cable through cable gland and connect to terminal. If the Ex-loudspeaker is to be earthed, it must be done correctly using the specially marked screws. Tighten cable gland and screw lid back on with 2-3 Nm to assure IP grade. Fasten the bracket with 3 screws and ensure to use all washers in the intended position. (To isolate the main

body from the bracket). To change the position of the loudspeaker, please adjust the bracket (by loosening / tightening the screws) as

required. Use only certified/specified cable glands and blanking plugs. The aluminum surface of the loudspeaker should be regularly treated with paint at the same interval as with other

similar outdoor equipment. For optimum performance, always use the correct voltage / power and operate within the frequency limits as

stated. Do not open loudspeaker when energized. This loudspeaker is supplied with a 2 year warranty against defective materials and workmanship.

Sound pressure levels at 1W/1m

100V line Primary

nominal tappings Red : Yellow 8,0 W Red : Green 4,0 W Red : Blue 2,0 W

II 2G Ex d e mb IIC T6 Gb -50°C ≤ Ta +50°C

II 2G Ex d e mb IIB+H2 T6 Gb -50°C ≤ Ta +50°C

Certification: NEMKO 10ATEX1051

Specifications IIB IIC Material / Color Aluminum alloy SS4263 / RAL7035 Mounting Bracket Termination e-chamber, screw terminals Weight w/transformer 2,0 kg IP-rating 66 / 67 Max. / min. amb. temp 50C / -50C Rated / max. power 8 W / 8 W SPL 1W/1m 100 dB 94 dB SPL rated power 108 dB 102 dB Effective freq. range 550 – 7000 Hz 650-7000 Dispersion (-6dB) 1kHz / 4kHz 160 / 45 105 / 35Directivity factor, Q Options Impedances, colors, labels

Page 9: Product Catalogue for Operation Spares

4.0 DNH DSP-15EExmN(T)

Page 10: Product Catalogue for Operation Spares

DNH AS Phone................... + 47 35 98 56 00 Fax………............. + 47 35 98 56 10 E-mail...………............ [email protected] Web-Site…………….. www.dnh.no

DNH WW Ltd Phone……. + 44 1908 275 000 Fax.............+ 44 1908 275 100 E-mail…[email protected]

DNH Speakers Inc Phone........... + 1 484 494 5790 Fax…........... .+ 1 484 494 5793 [email protected]

DNH GmbH Phone… + 49 040 6569 30-0 Fax....... + 49 040 6569 30-30 E-mail...........…. [email protected] ISO 9001 CERTIFIED

DNH reserves the right to alter specifications without notice

HEAD OFFICE, NORWAY ENGLAND GERMANY USA

http://companyweb/teknisk/Dataark/Ex_EEx/Aluminum horns/HS-15EExmN(T) doc

Rev. 05.03.2013

HS-15EExmN(T)

Installation, Operation and Maintenance Procedures

Unscrew lid, lead cable through cable gland and connect to terminal according required power. If the Ex-loudspeaker is to be earthed, it must be done correctly using the specially marked screws. Tighten cable gland and screw lid back on with 2-3 Nm to assure IP grade. Fasten the bracket with 3 screws and ensure to use all washers in the intended position. (To isolate the main

body from the bracket). To change the position of the loudspeaker, please adjust the bracket (by loosening / tightening the screws) as

required. Use only certified/specified cable glands and blanking plugs. The loudspeaker should be checked on a regular basis to avoid any build up of debris. The aluminum surface of the loudspeaker should be regularly treated with paint at the same interval as with other

similar outdoor equipment. For optimum performance, always use the correct voltage / power and operate within the frequency limits as

stated. Do not open loudspeaker when energized. This loudspeaker is supplied with a 2 year warranty against defective workmanship.

Sound pressure levels at 1W/1m IIB version

Primary nominal tappings 100V

From loudspeaker White to black

Red Yellow 15,0 W Red Green 10,0 W Red Blue 7,5 W

White to white Red Yellow 4,0 W Red Green 2,6 W Red Blue 2,0 W

Specifications IIB IIC Material / Color Aluminum alloy / RAL7035 Mounting Bracket Termination e-chamber, screw terminals Weight w/transformer 2,8 kg IP-rating (UL equivalent) 67 Max. / min. amb. temp 60C / -50C Rated / max. power 15 W / 15 W SPL 1W/1m 105 dB 101 dB SPL rated power 116 dB 113 dB Effective freq. range 410 – 7000 Hz 420-7000 Dispersion (-6dB) 1kHz / 4kHz 140 / 40 105 / 35Directivity factor, Q Options Impedances, colors, labels

II 2 G D Certified by / Certification code / Number:NEMKO / EEx de IIB+H2 T5 / 98 ATEX 201 Certified by / Certification code / Number:NEMKO / EEx de IIC T5 / 98 ATEX 201

Page 11: Product Catalogue for Operation Spares

5.0 MEDC XB15

Page 12: Product Catalogue for Operation Spares

15 JOULE XENON BEACONSEExd, WeatherproofXB15 Range

IntroductionThese certified beacons have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required.

The housings are manufactured completely from a U.V. stable, glass reinforced polyester. Stainless steel screws and mounting bracket are available ensuring a totally corrosion-free product.

The model XB15 contains a supervisory diode and four wire lead connections for alarm applications.

Units can be painted to customer specification and supplied with identification labels.

H Zone 1 and Zone 2 use.H EExd IIC, T4/T5/T6.H ATEX approved, Ex II 2GD.H UL listed for USA and Canada – Hazardous locations: Class I, Div. 2, Groups A, B, C & D. Class II, Div 2 Groups F & G Class I, Zone 1, AExd IIC T4/T5/T6. – Ordinary locations: Visual-Signal Device. – Marine listed.H GOST 'R' & 'K' Certified.H Brazilian (Inmetro) Certified.H IEC-Ex Approved.H IP66 & 67.H Certified temperature –55°C to +70°C.H Pipe mount or direct mount enclosure.H Corrosion-free GRP.H Four wires and supervisory diode.H Optional stainless steel backstrap.H Various lens colours.H Optional relay or telephone initiate.H Optional cast or wire lens guard.H Up to 3 x M20 or 3 x M25 entries.H Filament version available (100W max). See data sheet for FB15.

XB15 Direct Mount (with backstrap and wire guard)

Cooper MEDC Ltd, Colliery Road, Cooper MEDC (USA) 3413 North Sam Houston Parkway, Pinxton, Nottingham NG16 6JF, UK. West, Houston, Texas 77086, USA. Tel: +44 (0)1773 864100 Tel: +1 (713) 937 9772 Fax: +44 (0)1773 582800 Fax: +1 (713) 937 9773

Sales Enq. Fax: +44 (0)1773 582830 Sales Orders Fax: +44 (0)1773 582832E-Mail: [email protected] Web: www.medc.com

6DS120/J

ATEX

XB15Pipe Mount

Note: UL only(with cast guard)

Now GOST

‘R’ & ‘K’

Certified

GOST

Page 13: Product Catalogue for Operation Spares

Finish Code Natural Black N Red R Blue B Yellow Y Green G White W Special Finish S

Color Code Red R Blue B Green G Amber A Yellow Y Clear C

Fpm Code 60 06 80 08 120 12

Voltage Code 24V d.c. 024 48V d.c. 048 110V a.c. 110 120V a.c. 120 230V a.c. 230 240V a.c. 240 254Va.c. 254

Guard Code None N Cast C Wire W

All the above specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

11/09

Ordering RequirementsThe following code is designed to help in the selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available for immediate shipping – contact sales office for details.

Lens Lens Unit Unit Model Certification Voltage Flashrate Color Guard Fixing Options Finish

XB15

Unit Fixing Code Pipe mount P*† Direct mount D† Direct w/backstrap B†

Option Code None N Tag label T Duty label D Relay initiate* R Telephone initiate† I Blanking Plug P

SpecificationCertification: CENELEC EN50014 & EN50018. ATEX Cert. No. Baseefa 04ATEX0009X. BASEEFA EExd IIC T4/T5. UL Listed for USA and Canada: – Hazardous locations Class I, Div 2, Groups A, B, C & D. Class II, Div 2 Groups F & G Class 1, Zone 1, AExd IIC T4/T5/T6. UL listing No. E187894. – Ordinary locations: Visual Signal Device. – Marine Listed UL listing No. S8128 GOST 'R' Certification: 1 Exd IIC T4/T5 Russian Fire alarm (VNIIPO) approved GOST 'K' Certification: Exd IIC T4/T5 Brazilian (Inmetro) Certified: BR-Ex d IIC T3/T4/T5/T6 IEC-ex ApprovedMaterial: Body: Glass reinforced polyester. Lens: Glass. Backstrap: stainless steel 316. Wire Guard (optional): Stainless steel wire. Cast Guard (optional): Aluminium LM25M.Finish: Natural black or epoxy painted to customer specification.Models: XB15 ATEX – Available in direct mount version only. XB15 UL – Available in pipe and direct mount versions.Voltage: 24, 48V d.c. 110, 120, 230, 240, 254V a.c.Tube Energy: 15 Joules.Tube Life: >1 x 106 flashes.Flash Rate: 60, 80, 120 fpm.Certified -55°C to +40°C (T6).Temperature: -55°C to +55°C (T5). -55°C to +70°C (T4).Weight: Pipe mount: 2.6kg; Direct mount: 3.0kg.Ingress IP66 & IP67.Protection:Entries: ATEX version: Supplied as 2 x M20 entries as standard – Up to 3 x M20 or 3 x M25 entries. Contact sales office to order. UL version: Supplied as 2 x ¾" NPT (direct mount) or ¾" (pipe

mount) as standard. Other options available: Up to 3 x ½" NPT or 3 x ¾" NPT (direct mount); ½" NPT (pipe mount) – contact sales office to order.Terminals: Direct mount: 12 x 2.5mm2. Pipe mount: 8 x 2.5mm2.

Multiplying Factor for Coloured Lenses:

Red Blue Amber Green Yellow

0.15 0.12 0.51 0.49 0.86

Certification Code ATEX B UL UL UL (ordinary UW location) UL Marine U GOST 'R'* G GOST 'K' K Inmetro DM IEC Ex J *VNIIPO approved as standard.

*Only available on UL Listings.

†Contact MEDC if ½" NPT is required.

*Suitable for 24V d.c. supplies only.

†Not available on UL/UW versions.

Relay Initiate: Available on all versions - operates with 24V d.c. initiate supplies only.

Labels: Tag/Duty label option.

Electrical Ratings: d.c a.cVoltage 24 48 110 120 230 240 254Current (A) 0.99 0.73 0.4 0.4 0.2 0.2 0.17Effective Candlepower (Cd) – 330 at 60 flashes per min.Peak Candlepower – 520,000 (Peak candlepower is the maximum light in-

tensity generated by a flashing light during its light pulse)

Page 14: Product Catalogue for Operation Spares

6.0 ELEMEC PLUS

Page 15: Product Catalogue for Operation Spares

GAI-Tronics Systems Elemecplus

Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets

The Elemecplus is a digitally controlled Public Address and General Alarm System (PA/GA). Designed principally for life critical installations in the Oil and Gas market, it is also suitable for many industrial communications requirements.

The Elemecplus high integrity Public Address & Alarm System is commonly used on Oil & Gas Platforms, FPSO's, Power Stations & Oil Refineries, Chemical Plants & Industrial Complexes Worldwide where the safety of all personnel is of immense importance.

The equipment is specifically and fundamentally designed for failsafe operation, with extensive system and fault status monitoring for maximum availability at all times.

In addition to General Paging and Emergency Broadcasts, Alarms can be automatically initiated, e.g. from fire and gas alarm and emergency shut down systems. Alarm tones or pre-recorded digital voice evacuation messages can be broadcast.

• 600W Intelligent Power Amps

• Up to 19.2 kW (64 amplifiers) of Audio Power per system

• Fully duplicated, duplicated or single configuration

• Compliant to UKOOA, PFEER, IMO, SOLAS, DNV, NORSOK requirements / guidelines

• Multiple Hot Standby power amplifiers

• Plug and socket construction for easy maintenance

• Up to 16 fully monitored full featured microphone access panels over 3-pair cable

• Message storage and replay up to 2 mins

• Auto access panel lockout on panel failure (time-configurable)

• System status and fault log monitoring via Ethernet link

• Emergency Access fallback operation

• Intrinsically Safe (I.S.) ATEX microphone panels to Group IIB

• Auxiliary Audio Input e.g. music

• CE Compliant

• PABX Telephone & Page/Party® Access

• Engineers Test Panel provision

• Fibre Optic link to remote amplifiers

• Auto alarm override feature

• Supports Alarm Zoning requirements

• Amplifier Sub-Zoning

• Two priority levels for routine speech

• Beacon Cable Monitoring

• Ultrasonic Loudspeaker Network Monitoring

Page 16: Product Catalogue for Operation Spares

GAI-Tronics Systems Elemecplus

Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets

PA Controller

The centre of the Elemecplus PA/GA system is the Controller Unit. Designed for 19" Equipment cabinet mounting, this unit is microprocessor controlled and software configurable.

The Controller Unit provides continuous monitoring functions for up to 16 Microphone Access Panels and sends/receives data from the Elemecplus Power Amplifiers, to provide complete high integrity system monitoring, from microphone panel to loudspeaker. Integral Alarm Tone Generator circuits are also monitored.

A backlit LCD provides instant status information of system activity and faults; a major advantage to operator and maintenance personnel. To increase security, a watchdog circuit allows Emergency fallback to increase the integrity. This allows manual initiation of Emergency

Speech and audible alarms in the event of processor failure.

For ease of installation and maintenance all cabinet internal connections are on a plug/socket basis. The software control is designed to be as flexible as possible, and can easily be downloaded to the Controller.

As a security measure, Alarm Tone types can only be changed by replacing an I.C. (EPROM) on the main PCB within the Controller.

Hot standby Amplifier Control is provided whereby a powered spare amplifier/s is automatically connected to the loudspeaker network of a failed amplifier/s. PABX access and page/party access is configured so that telephone/intercom inputs are digitally stored and replayed to completely eliminate the possibility of acoustic feedback between telephone/intercom & local loudspeaker.

Eight individually programmed beacon control outputs are available to operate beacon relays during emergency speech/alarm broadcasts. A numerical keypad enables certain test and setup functions to be implemented e.g. Amplifier Tick Tone, Alarm & PABX broadcast levels.

The controller can be supplied in duplicated format for additional redundancy.

Web Server Board

The unique IP address of each web server board enables remote monitoring of the system. The board may be LAN or WAN, or in turn connected to the Internet giving world-wide access to system monitoring without dedicated viewer software.

System monitoring is divided into web pages, with the web server opening a general introductory page.

Control unit input and output functions are monitored by selecting the Control Unit and Signals.

From this page the real time state of the systems alarm and beacon outputs, together with the control inputs can be monitored.

This enables the user to monitor all inputs from other devices such as the fire & gas system, therefore extending the monitoring capacity of the web server connection.

Additionally, it allows the user to have a remote mimic display of all current messages seen on the control unit LCD within the main Elemecplus equipment cabinet/s.

The access panel monitoring page mimics the layout and operation of access panels connected to the Elemecplus control unit being viewed.

As key functions are operated the monitoring panel mimics the LEDs indicating the selection of functions and/or alarms.

A drop-down menu located at the top of the page permits the selection of one or all access panels.

Page 17: Product Catalogue for Operation Spares

GAI-Tronics Systems Elemecplus

Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets

Intelligent Power Amplifier

At the heart of all GAI-Tronic Public Address Systems is the D600i Class D Power Amplifier (2x300W). The D600i is designed for use in GAI-Tronics high integrity Elemec, NOVA and Advance public address and alarm systems. GAI-Tronics designs and manufactures sophisticated public address and alarm systems to suit specific markets and applications. The NOVA system addresses multiple zones, multiple networks and multiple speech path applications such as large petrochemical facilities. Elemecplus addresses self-contained applications such as platforms and FPSOs. ADVANCE combines public address with multi-station intercom capability.

The field proven D600i amplifier is designed for performance in a range of applications, from continuous 300W RMS rated outputs for Alarm Systems to high quality music reproduction. Each amplifier comprises 2 x 300W channels, each capable of independent operation. To reduce the risk of single point failure, on AC systems the Amplifier has its own internal power supply. Fault protection and ultrasonic load sensing are contained within the Amplifier. Load sensing is easily configured by use of pushbuttons on the front of each amplifier. This load sensing facility allows loudspeaker monitoring and automatically detects changes in the load of the connected loudspeakers. Thermostatically controlled fans, integral to each unit, provide forced air cooling to the output power devices only during high temperature operation. System expansion is easily achieved by simply adding more amplifiers without the need to change controller hardware.

Local/Remote Access Panel

Several types of access panel are available for use with the Elemecplus PA/GA system.

The panels are available in six formats - 19" console mounted, desktop mounting and indoor/outdoor IP66 bulkhead mounting. All are available for use in 'safe areas' weatherproof enclosures or I.S. panels can be supplied for hazardous areas to Zone 1 as ATEX certified EEx ib IIB T4. To standardise equipment supply each variant uses the same panel insert.

Either a single set of data control and audio outputs are provided connected to the Central Equipment via only a 3 pair cable, or fully duplicated circuits (from dual segregated switch contacts to dual panel outputs) are also available for use with dual A/B systems.

The access panel insert assembly comprises a mild steel plate pierced to accommodate up to 30 pushbuttons, with a textured polycarbonate overlay with 'secret until lit' status LED's.

All pushbuttons can be individually programmed by software to perform any of the microphone panel functions.

Up to 8 zone select pushbuttons and 8 alarm pushbuttons can be fitted. Emergency Speech and

Alarm pushbuttons are fitted behind a Perspex cover to prevent accidental operation. 'All call' and Sleeping Quarter zone pushbuttons can similarly be fitted behind the cover if required.

Gooseneck or fist microphone options are available with LED “VU” indication. LED's adjacent to the pushbuttons illuminate only when the switch press has been accepted by the Central Equipment to provide added confidence to the operator. Pushbutton legends are easily interchangeable.

Up to 16 fully fitted microphone panels can be connected to the Elemecplus PA/GA system. During Emergency Speech broadcasts the audible Alarms can be programmed to attenuate (typically 12dB) or completely mute.

Both routine and Emergency Speech access are standard with two routine speech priority levels. This is used to allow routine speech to be heard over some alarms but not other alarms. This is in addition to the priority between individual panels.

Page 18: Product Catalogue for Operation Spares

GAI-Tronics Systems Elemecplus

Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets

TECHNICAL SPECIFICATIONS Controller Unit Three keyswitches are provided - functionality is as follows: Keyswitch 1 - Used for duplicated A/B systems. Either system A or B can be set on master to source audible alarms or voice recorded messages. Keyswitch 2 - Used to select either local or remote Power Amplifiers to be driven by the controller. Keyswitch 3 - Used to inhibit Auto Alarm inputs e.g. to prevent false alarms during F & G system commissioning.

Mechanical Dimensions: 483W x 177H x 390D (mm) Material: Mild Steel Electrical • Power 24V DC +/-10% <100mA (unit itself)

• 100mA fused outputs provided for Access Panels, Beacon Relays etc.

• Microphone Panel Audio Input 2.2V p.p. 600Ω • Microphone Panel Data, RS485 semi-duplex • Page/Party interface Input Level 1.5V rms • Control Inputs e.g. Auto Alarms Up to 16 Dry contact or

24V DC • Amplifier Audio Output 2.2V p.p. • Amplifier Data Link RS485 semi-duplex • A/B System interlink 6 pair connection Audio 2.2V p.p.

Data RS485 Fully-duplex • Auxiliary Input e.g. background music 2.2V p.p. 600Ω

Class ‘D’ Amplifier LCD Indicator Panel on the front of the amplifier displays the following information: • High Temperature Operation • Output Overload Condition • Amplifier Shutdown Protection Active • Power Healthy • Amplifier Enabled / Disabled • Fuse Failure • Zone Allocation • Bargraph at output level

Electrical • Output power: 2x300W • Line output voltage: 70V or 100V rms (or client spec) • Input sensitivity: 0dBm (0.775V rms) for rated output • Frequency response: 50Hz - 18kHz (-3dB points) • Total harmonic distortion: <2% at 1kHz, full load

• Operating Voltage Options: 48V DC, Mains 120V or 230V AC

• Operating Temperature: -20°C to +50°C • Efficiency: 80% (typ) • Signal to Noise ratio: 60dB (A)

Mechanical • Dimensions: 390D x 483W x 88H, DIN standard 2U • Mounting: 19" Standard Rack (Shelf or Slider) • Material: Welded Steel Tray with Vented Lid • Finish: Black Textured Stoved Enamel • Output Audio Connectors: WAGO 5 way connector • AC Power: IEEE Standard, 3 pin • DC Power: Molex 2 way 100mm Mini Fit connector • Audio / Data Comms (RS485): IDC • Weight: 24Kg max

Access Panel • Up to 30 pushbuttons • System Status LEDs • 300mm gooseneck or fist noise cancelling microphone • 3 pair connection cable

Electrical • Power 24V DC nominal (15-30V DC) <65mA • Audio Pair, uni-directional, 2.2V pp • Data pair, RS485 semi-duplex • Audio Conditioning 2:1 compression • VU Meter LEDs in 6dB steps • S/N Ratio >60dB • Environmental -20°C to +50°C RH95%

Mechanical

Dimensions Mounting Material Connections

Resist-ance

19" Console

Panel

483W x 177H x

135D (mm)

19" Console Mild Steel

2.5mm² screw

terminal

Desktop Panel

269W x 90H x 230D

(mm) Desktop Mild Steel

15 way 'D'

connector

Indoor Bulkhead

Panel

450W x 324H x

173D (mm)

Wall Mount Mild Steel

2.5mm² screw

terminal

Outdoor Bulkhead

Panel

400W x 300H x

210D (mm)

Wall Mount

Stainless Steel

2.5mm² screw

terminal

IP66 (door

closed)

I.S. GRP 280W x 280H x

170D (mm)

Wall Mount

Glass Reinforced Polycarbon-

ate

2.5mm² screw

terminal IP66

Page 19: Product Catalogue for Operation Spares

GAI-Tronics Systems Elemecplus

Digitally Controlled PA and Alarm System PA/GA With Class ‘D’ Amplifier, for Oil and Gas Markets

GAI-Tronics® - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - www.gai-tronics.co.uk GAI-Tronics® (Corporate) - USA - Tel: +1(610) 777 1374 - Toll Free: 800 492 1212 - Fax: +1(610) 796 5954 - www.gai-tronics.com GAI-Tronics® S.r.l - Italy - Tel: +39 02 48601 460 - Fax: +39 02 4585 625 - www.gai-tronics.co.uk GAI-Tronics® - Malaysia - Tel: +60 3 8945 4035 - Fax: +60 3 8945 4675 - www.gai-tronics.co.uk GAI-Tronics® Austdac - Australia - Tel: 011 61 28 851 5000 - Fax: 011 61 29 899 2490 - www.austdac.com.au An ISO 9001, ISO 14001, OHSAS 18001 Registered Company The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.

B191-2-1112B/CN37346-001

DU

PLIC

ATED

AT E

ACH

PO

INT

ExLO

UD

SPEA

KERS

UP

TO 8

BRO

AD

CAST

ZON

ES

LOCA

LLO

UD

SPEA

KERS

MU

TE

Ex B

EACO

NS

24 R

ELAY

O/P

’S

PABX

ACCE

SS

RS23

2FA

ULT

/EVE

NT

LOG

ExPA

GE

PART

YA

CCES

S

ALA

RMAC

CESS

RACK

‘A’

RACK

‘B’

3PA

IR

UP

TO 1

6 IN

TRIN

SICA

LLY

SAFE

REM

OTE

ACCE

SSPA

NEL

S

6PA

IR

SERI

AL

SYST

EM IN

TERL

INK

PA CON

TRO

LLER

19”A

CCES

SPA

NEL

POW

ERA

MPL

IFIE

R

Page 20: Product Catalogue for Operation Spares

7.0 CLASS D AUDIO AMPLIFIER

Page 21: Product Catalogue for Operation Spares

GAI-Tronics Systems Class D Audio Power Amplifier

D600i, dual 300W channels for Elemecplus PA/GA System

Efficiency 80% (240VAC 100V Line) Class D Operation

LCD Status Indication Dual Channel (300W per) split amp

Comprehensive fault monitoring 600W 2U Modular Design

User-friendly Set up & Commissioning At the heart of all GAI-Tronic Public Address Systems is the D600i Class D Power Amplifier (2x300W). The D600i is designed for use in GAI-Tronics high integrity Elemec, NOVA and Advance public address and alarm systems. GAI-Tronics designs and manufactures sophisticated public address and alarm systems to suit specific markets and applications. The NOVA system addresses multiple zones, multiple networks and multiple speech path applications such as large petrochemical facilities. Elemecplus addresses self-contained applications such as platforms and FPSOs. ADVANCE combines public address with multi-station intercom capability. The field proven D600i amplifier is designed for performance in a range of applications, from continuous 300W RMS rated outputs for Alarm Systems to high quality music reproduction. Each amplifier comprises 2 x 300W channels, each capable of independent operation. To reduce the risk of single point failure, on AC systems the Amplifier has its own internal power supply.

Fault protection and ultrasonic load sensing are contained within the Amplifier. Load sensing is easily configured by use of pushbuttons on the front of each amplifier. This load sensing facility allows loudspeaker monitoring and automatically detects changes in the load of the connected loudspeakers. Thermostatically controlled fans, integral to each unit, provide forced air cooling to the output power devices only during high temperature operation. System expansion is easily achieved by simply adding more amplifiers without the need to change controller hardware.

Page 22: Product Catalogue for Operation Spares

GAI-Tronics Systems Class D Audio Power Amplifier

D600i, dual 300W channels for Elemecplus PA/GA System

GAI-Tronics® - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - www.gai-tronics.co.uk GAI-Tronics® (Corporate) - USA - Tel: +1(610) 777 1374 - Toll Free: 800 492 1212 - Fax: +1(610) 796 5954 - www.gai-tronics.com GAI-Tronics® S.r.l - Italy - Tel: +39 02 48601 460 - Fax: +39 02 4585 625 - www.gai-tronics.co.uk GAI-Tronics® - Malaysia - Tel: +60 3 8945 4035 - Fax: +60 3 8945 4675 - www.gai-tronics.co.uk GAI-Tronics® Austdac - Australia - Tel: 011 61 28 851 5000 - Fax: 011 61 29 899 2490 - www.austdac.com.au An ISO 9001, ISO 14001, OHSAS 18001 Registered Company The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.

B192-1-1009B/CN34766-001

SPECIFICATIONS

LCD Indicator Panel on the front of the amplifier displays the following information: • High Temperature Operation • Output Overload Condition • Amplifier Shutdown Protection Active • Power Healthy • Amplifier Enabled / Disabled • Fuse Failure • Zone Allocation • Bargraph at output level

Electrical • Output power: 2x300W • Line output voltage: 70V or 100V rms (or client spec) • Input sensitivity: 0dBm (0.775V rms) for rated output • Frequency response: 50Hz - 18kHz (-3dB points) • Total harmonic distortion: <2% at 1kHz, full load • Signal to Noise ratio: 60dB (A) • Operating Voltage Options: 48V DC, Mains 120V or

230V AC • Operating Temperature: -20°C to +50°C • Efficiency: 80% (typ)

Mechanical • Mounting: 19" Standard Rack (Shelf or Slider) • Material: Welded Steel Tray with Vented Lid • Finish: Black Textured Stoved Enamel • Output Audio Connectors: WAGO 5 way connector • AC Power: IEEE Standard, 3 pin • DC Power: Molex 2 way 100mm Mini Fit connector • Audio / Data Comms (RS485): IDC • Weight: 24Kg max

Power Consumption in Full Power Mode • 230V = 3.18A Consumption 731.0 Watts • 120V = 6.57mA Consumption 793.0 Watts • 48V = 17.01A Consumption 817.0 Watts

Power Consumption in Idle Mode • 230V = 150mA Consumption 34.5 Watts • 120V = 300mA Consumption 36.0 Watts • 48V = 600mA Consumption 28.8 Watts

DIMENSIONS

• 390D x 483W x 88Hmm, DIN standard 2U GAI-TRONICS®

APPROVALS

This mark indicates compliance with the following directives: Radio & Telecommunications Terminal Equipment Directive 1999/5/EC (R&TTE)

ORDER INFORMATION For order codes and details, please contact: T: 01283 500500, F: 01283 500400, E: [email protected]

Page 23: Product Catalogue for Operation Spares

8.0 RW2000 B-series

Page 24: Product Catalogue for Operation Spares

RADWIN 2000 product portfolio

RADWIN 2000 PORTFOLIO CARRIER-CLASS POINT-TO-POINT SOLUTIONSRADWIN 2000 carrier-class SUB-6 GHz Point-to-point portfolio is ideal for carriers and a variety of vertical markets that require high capacity backhaul and access connectivity

Page 25: Product Catalogue for Operation Spares

The RADWIN 2000 portfolio offers sub-6 GHz licensed and unlicensed wireless broadband products that deliver high throughput of up to 200 Mbps, long range and unmatched robustness. Supported bands include 2.3-2.7 GHz, 3.3-3.8 GHz, 4.4-6.0 GHz and 5.9-6.4 GHz. Compact and robust, RADWIN 2000 products provide Ethernet and native TDM (up to 16 E1s/T1s), thus enabling seamless migration from TDM to all-IP networks.

RADWIN 2000 radios incorporate state-of-the-art technologies including MIMO and OFDM. Unique air interface capabilities secure performance optimization, enabling high spectral efficiency and robust performance in dense radio environments and multipath conditions. In addition, RADWIN 2000 radios support advanced networking features such as QoS, VLAN and Q in Q.

RADWIN 2000 radios can be deployed in point-to-point and multiple point-to-point topologies and support intra- site and inter-site TDD synchronization to maximize network capacity. To ensure maximum service availability, RADWIN radios incorporate built-in 1+1 redundancy and ring protection functionality.

RADWIN’s products comply with worldwide regulations and standards and are deployed globally by leading carriers, service providers and public and private networks requiring high-capacity connectivity.

RADWIN 2000 PORTFOLIOCARRIER-CLASS POINT-TO-POINT SOLUTIONS

Page 26: Product Catalogue for Operation Spares

RADWIN 2000 Portfolio Highlights

» Up to 200 Mbps net aggregate throughput

» Native TDM (up to 16 E1s/T1s) + Ethernet

» Long range - up to 120 Km/75 miles

» Telco-grade, extremely robust in harsh conditions

» Advanced OFDM & MIMO technologies for operation in nLOS/NLOS and dense radio environments

» Multi-band radio supports multiple frequency bands on same platform

» QoS and VLAN capabilities

» Ethernet service protection through 1+1 and ring topologies

» Extremely simple to install and maintain

Page 27: Product Catalogue for Operation Spares

HIGH-CAPACITY RADIOS FOR IP & TDM BACKHAUL

RADWIN 2000 C-Series

Deliver up to 200 Mbps net aggregate throughput and up to 16 E1s/T1s.

RADWIN 2000 B-Series

RADWIN 2000 B-Series radios deliver up to 50 Mbps net aggregate throughput and up to 8 E1s/T1s. The radios come with an extremely small form factor antenna and include built-in connectors for optional external antenna. This unique configuration enables greater installation flexibility and reduces inventory burden.

RADWIN 2000 B and C-Series radios are ideal for operators seeking carrier-class solutions for IP and TDM backhaul, as well as for private networks requiring IP connectivity with high availability and guaranteed QoS. Delivering IP and TDM over the same link enables seamless migration from legacy TDM to all-IP networks.

RADWIN 2000 B and C-Series radios operate in symmetric and adaptive asymmetric modes whereby uplink and downlink capacity is dynamically allocated based on traffic loads and air-interface conditions. Extremely simple to install and maintain, these solutions operate flawlessly in the most challenging surroundings, including non line-of-sight scenarios, dense environments and extreme temperatures.

For operators who want to break the capacity barrier and meet the skyrocketing demand for broadband,RADWIN’s radios are the right choice.

0

0 10 20 30 40 50 60 70 80 90 100 110 120 Km

Mbps

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

210

RADWIN 2000 C-Series Total Throughput@ 40 MHz Channel BW

* 28 dBi antenna * 28 dBi antenna

RADWIN 2000 B-Series Total Throughput@ 20 MHz Channel BW

1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101

105

109

113

117

121

0

10

20

30

40

50

60Mbps

Km

Page 28: Product Catalogue for Operation Spares

RADWIN 2000 C-Series & RADWIN 2000 B-Series Highlights

» 50-200 Mbps net aggregate throughput

» Native TDM (up to 16 E1s/T1s) + Ethernet

» Long range - up to 120 Km/75 miles

» Asymmetric capacity; fixed or dynamic channel allocation

» Extremely robust in harsh weather conditions

» Operating in nLOS/NLOS and dense environments

» Telco-grade, with advanced OFDM & MIMO technologies

» QoS and VLAN capabilities

» Ethernet service protection through 1+1 and ring topology

» GBE support

» Low latency (typical) < 3msec

» Extremely simple to install and maintain

“RADWIN 2000 is robust and durable enough to withstand the toughest outdoor conditions, and is very simple to install and maintain.” Jim MakepeaceDirector of Network Engineering Revol WirelessUSA

“RADWIN’s links have exceeded our expectations in terms of capacity, security and robustness.

The bandwidth provided by the wireless network has been phenomenal and we are able to transfer massive amounts of data files and x-ray images in seconds.”Dr I Hansrod Medical Director Jackpersad Radiology CenterSouth Africa

ODU with Integrated Antenna

IDU-C

Ethernet + 4, 8, 16 E1s/T1s indoor unit

IDU-E

Ethernet + 2 E1s/T1s indoor unitIDU-C

IDU-E

IDU-H

Ethernet aggregation unit for 6 ODUs

Page 29: Product Catalogue for Operation Spares

* 5.x Ghz, 28 dBi antenna

* 5.x Ghz, 28 dBi antenna

RADWIN 2000 A-SERIES FOR IP & TDM ACCESS

RADWIN 2000 A-Series radios are available in two models:• Supporting 25 Mbps net Ethernet throughput and up to 4 E1s/T1s• Supporting 10 Mbps net throughput. The unit capacity can easily be upgraded to 25 Mbps via a software key. This enables low initial investment while securing further capacity growth.

RADWIN 2000 A-Series radios are ideal for carrier access applications thatrequire SLAs and for private networks seeking carrier-class solutions.Incorporating the RADWIN 2000 advanced features, RADWIN 2000 A-Seriesradios enable optimal spectrum utilization using MIMO and OFDM technologies,combined with RADWIN’s field-proven interference mitigation techniques critical for operation in dense urban environments.

Housed in compact, extremely small form factor units, the RADWIN 2000A-Series radios are ideal for deployments where a small equipment footprintis required.

“We chose RADWIN 2000 because we liked the throughput of 100 Mbps which was the perfect fit for our requirements. The installation was easy and fast, and connectivity was easily achieved even in a difficult 5.8 GHz band where the spectrum is very tight.”Kevin KlugePlanning EngineerBug Tussel Wireless CarrierWisconsin, USA

“What really sets RADWIN’s systems apart is that they are exceptionally robust and transmit video from mega-pixel cameras with crystalline image quality. Thanks to RADWIN’s surveillance network, the Maserà municipality is providing a safe city environment for its citizens.”Lorenzo ZanfardinDirector SAIV (SI)Italy

RADWIN 2000 A-Series 25 Mbps - Total Throughput

Channel Bandwidth - 20 MHz

Channel Bandwidth - 10 MHz

Channel Bandwidth - 5 MHz

Channel Bandwidth - 20 MHz

Channel Bandwidth - 10 MHz

Channel Bandwidth - 5 MHz

RADWIN 2000 A-Series 10 Mbps - Total Throughput

Mbps12

10

8

6

4

2

0Km1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 10

010

511

011

512

0

Mbps

30

25

20

15

10

5

0Km

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

105

110

115

120

Page 30: Product Catalogue for Operation Spares

RADWIN 2000 Specifications

Configuration

Architecture ODU: Outdoor Unit with Integrated Antenna, Embedded Antenna or Connectorized Unit for External AntennaIDU: Indoor Unit or PoE device

IDU to ODU Interface Outdoor CAT-5e cable; Maximum cable length: 100m for 100BaseT and 75m for 1000BaseT

Max Throughput

Total Throughput TDM E1/T1 Trunks

RADWIN 2000 C-Series 200 Mbps Aggregated 16

RADWIN 2000 B-Series 50 Mbps Aggregated 8

RADWIN 2000 A-Series25 Mbps Aggregated 4

10 Mbps Aggregated -

Radio

C-Series B-Series A-Series (25 Mbps) A-Series (10 Mbps)

Range Up to 120km/75 miles

2.297-2.482 2.496-2.700 GHz 3.300-3.800 GHz 4.390 - 5.010 4.800-6.060 GHz 5.890-6.410 GHz

2.402-2.482 GHz2.499-2.690 GHz4.800-6.060 GHz 5.890-6.410 GHz

2.402-2.482 GHz

4.890-5.960 GHz

2.402-2.482 GHz

4.890-5.960 GHz

Channel Bandwidth 5/10/20/40 MHz 5/10/20/40 MHz 5/10/20 MHz 5/10/20 MHz

Maximum Tx Power 25 dBm @ 2.49-2.7 GHz, 3.3-3.8 GHz, 4.4-6.4GHz26 dBm @ 2.3-2.47 GHz

Adaptive Modulation & Coding Supported

Automatic Channel Selection Supported

Bandwidth Allocation Symmetric or Asymmetric

Diversity Polarization and Spatial Diversity supported

Spectrum View Built-in Spectrum Analyzer

Duplex Technology TDD

Radio Modes MIMO/Diversity/Single

Encryption, US Security AES 128, FIPS-197

TDD Synchronization Intra-site and inter-site using GPS ( C-Series & B-Series)

Maximum Information Rate Configurable in steps of 1Kbps

Radio Parameters at 20 MHz Channel Bandwidth

Modulation 2x2 MIMO-OFDM

BPSK QPSK 16QAM 64QAM

Forward Error Correction(FEC) Rate 1/2 1/2 3/4 1/2 3/4 2/3 3/4 5/6

Air Rate [Mbps] 13 26 39 52 78 104 117 130

Sensitivity (dBm) @ BER <10E-11, 20MHz Chbw -88 -86 -83 -81 -80 -72 -70 -67

Page 31: Product Catalogue for Operation Spares

The RADWIN name is a registered trademark of RADWIN Ltd. Specifications are subject to change without prior notification. © All rights reserved, February 2013

RADWIN LtdCorporate [email protected]

www.radwin.com

Ethernet Interface

Ports PoE Device: 1 port 10/100/1000BaseT IDU-C and IDU-E: 2 ports 10/100BaseT and 10/100/1000BaseT in IDU-C E0 IDU-H: 6 PoE ports, 10/100/1000BaseT 2 LAN ports, 10/100/1000BaseT, 2 SFP ports GbE

Connector RJ-45SFP Port Supported in IDU-C type FE and IDU-H type GbEService Protection Built in support: 1+1 and Ring topologyEthernet BridgingVLAN 802.1Q, 802.1P and QinQ TaggingQoS 4 levels supportedMaximum Frame Size 2048 bytesLatency < 3msecTDM InterfaceNumber of Ports Up to 16 E1s/T1s in IDU-C; 2 E1s/T1s in IDU-EType E1/T1 configurable by RADWIN ManagerFraming Unframed (transparent)Timing Independent timing per port, Tx and RxConnector RJ-45Standards Compliance ITU-T G.703, G.826Line Code E1: HDB3 @ 2.048 Mbps; T1: B8ZS/AMI @ 1.544 MbpsLatency Configurable: 5-20 msec (default: 8 msec)Impedance E1: 120Ω, balanced; T1: 100Ω, balancedJitter & Wander According to ITU-T G.823, G.824Service Protection Monitored Hot Standby (MHS) 1+1 (using IDU-C )ManagementLink Management Application RADWIN ManagerProtocol SNMP and TelnetNMS Application RADWIN NMS (RNMS)Web- based Management Web access via browser Mechanical

Dimensions and Weight

C & B-Series: ODU with Integrated Antenna: 37.1cm(w) x 37.1cm(h) x 11cm(d); 3.5 kg / 7 lbs C & B-Series: ODU Connectorized: 19.5cm(w) x 27.0cm(h) x 8.0cm(d); 1.8 kg / 3.6 lbsA-Series: ODU with integrated Antenna: 21.4(w)x19.7(h)x7.7(d)cm; 1.3kg / 2.8lbsA-Series Connectorized ODU: 17.1(w)x19.6(h)x7.2(d)cm; 1.1kg / 2.4lbsIDU-C: 43.6cm(w) x 4.4cm(h) x 21cm(d); 1.5 kg / 3.3 lbsIDU-E: 22cm(w) x 4.4cm(h) x 17cm(d); 0.5kg / 1.1 lbsIDU-H: 1U Half 19” width, 1.5kg / 3.3 lbs

PowerPower Feeding -20 to -60 VDC (dual feed in IDU-C); 100-240 VAC, 50/60 Hz

Power Consumption C&B-Series: 20-35W (ODU+IDU); 5-15W (ODU+PoE device)A-Series: 15W (ODU+IDU); 10W (ODU+PoE device)

EnvironmentalOperating Temperatures ODU: -35°C to 60°C / -31°F to 140°F; IDU: 0°C to 50°C / 32°F to 122°F

Humidity ODU: 100% condensing, IP67 (totally protected against dust and immersion up to 1m); IDU-C: 90% non-condensing

Shock and Vibration EN 300 019-2-4 IEC 60068-2 Class4M5

HazLoc ANSI/ISA: Class I and II, division 2 and Class III, Division 1 and 2 CAN/CSA: Class I, Division 21

Radio Regulations

FCC 47CFR, Part 15 Subparts C&E; Part 90 Subpart Y 47CFR, Part 27 (C & B-Series)1

IC (Canada) RSS-210, RSS-111 RSS 192, issue-3 (C & B-Series)EN (ETSI) 300 328; 301 893; 302 502, 302_326-2, (C & B-Series)WPC (India) GSR-38MII (China) 5.8 GHz Band RegulationSafetyFCC/IC (cTUVus) UL 60950-1, UL 60950-22, CAN/CSA C22.2 60950-1, CAN/CSA C22.2 60950-22ETSI EN/IEC 60950-1, EN/IEC 60950-22EMCFCC 47CFR Class B, Part15, Subpart BETSI EN 300 386, EN 301 489-1, EN 301 489-4CAN/CSA CISPR 22-04 Class BAS/NZS CISPR 22:2004 Class B

RADWIN 2000 Specifications

1 HazLoc in RADWIN 2000 C-Series 4.800-6.060 GHz FCC model only

Page 32: Product Catalogue for Operation Spares

9.0 RW-7100 IDU-E Series

Page 33: Product Catalogue for Operation Spares

Product Specifications

TDM Interface

Number of Ports 2 ports or no TDM ports

Type E1/T1; configurable by RADWIN Manager

Framing Unframed (transparent)

Timing Independent timing per port, Tx and Rx

Connector RJ-45

Standards Compliance ITU-T G.703, G.826

Line Code E1: HDB3 @ 2.048 Mbps; T1: B8ZS/AMI @ 1.544 Mbps

Latency Configurable 5-20 ms (default: 8 ms at 20 MHz Channel

Bandwidth)

Impedance E1: 120Ω, balanced; T1: 100Ω, balanced

Jitter & Wander According to ITU-T G.823, G.824

Ethernet Interface

Number of Ports Two Ethernet ports

Type 10/100 BaseT Auto-Negotiation (IEEE 802.3u); Framing/Coding IEEE 802.3

Connector RJ-45

Impedance 100Ω

VLAN Support 802.1Q, QinQ Tagging

Maximum Frame Size 2048 Bytes

Bridge Layer 2, self-learning of up to 1024 MAC addresses Hub/Bridge selectable

Latency 3 msec (typical at 20 MHz Channel Bandwidth)

ODU Interface

Connector RJ-45

Cable Outdoor CAT-5e cable; Maximum cable length: 100 m

Dry Contact Alarms

4 Outputs + 4 Inputs; configurable by RADWIN Manager

Mechanical

Dimensions 22cm(W) x 17cm(D) x 4.4cm(H)

Weight 0.5 kg/1.1 lbs

Power

Power Feeding 110 – 240 VAC*; -20 to -60 VDC

Power Consumption <5W

Environmental

Operating Temperatures 0°C to 50°C / 32°F to 122°F

Humidity Up to 90% non-condensing

Safety

TUV UL 60950-1, CAN/CSA-C22.2 No.60950-1

EN/IEC 60950-1

EMC

FCC 47 CFR Class B, Part15, Subpart B

ETSI EN 300 386, EN 301489-4

CAN/CSA CISPR 22-04 Class B

AS/NZS CISPR 22:2006 Class B

Ordering Information

RW-7102-2000 IDU-E with 2 TDM ports, 2 Ethernet interfaces and external alarms interfaces

RW-7100-2000 IDU-E with 2 Ethernet interfaces

*AC power adapters with plugs for various countries can be ordered separately (see product RW-9921-

003X in RADWIN Product Catalog).

IDU-E RW-71XX-2000

Corporate Headquarters

T. +972.3.766.2900

E. [email protected]

www.radwin.com

RW-71XX-2000 is part of the RADWIN Indoor Units Portfolio. The IDU-E product line

comprises of carrier grade half 19’’ indoor devices providing two E1/T1 interfaces

(configurable) and two Ethernet ports. Supporting independent clock per each

TDM port and wide range DC feed, IDU-E is a scalable, easy-to-use solution that is

compatible with both the RADWIN 2000 and WinLink 1000 radio portfolio.

The RADWIN name is a registered trademark of

RADWIN Ltd. Specifications are subject to

change without prior notification. © All rights

reserved, August 2010

DS RW-9924001X/01/08.10

Page 34: Product Catalogue for Operation Spares

10.0 ME3400E Switch

Page 35: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 19

Data Sheet

Cisco ME 3400E Series Ethernet Access Switches

Cisco® ME 3400E Series Ethernet Access Switches are next-generation Layer 2 and Layer 3 customer-located devices for service providers. Their design is based on the widely deployed Cisco ME 3400 Series Ethernet Access Switches. The Cisco ME 3400E Series helps service providers deliver four key attributes that are essential to next-generation Carrier Ethernet service: availability, flexibility, manageability, and security.

Product Overview

With service-provider-friendly features, the Cisco ME 3400E Series is the second-generation Cisco access switch

optimized for Ethernet-to-the-Business (ETTB) VPN services. It provides both high availability and service

flexibility for Carrier Ethernet business access deployments. The Cisco ME 3400E Series comes by default with

advanced Layer 2 VPN service features and the option to upgrade to Layer 3 VPN services, giving service

providers an out-of-the-box business VPN solution that can be scaled to meet future needs.

The Cisco ME 3400E Series (Figure 1) includes the following configurations:

Cisco ME 3400EG-12CS chassis (part number ME-3400EG-12CS-M) with 12 dual-purpose (10/100/1000

and Small Form-Factor Pluggable [SFP]) ports, four SFP uplinks, and two slots for field-replaceable

modular power supply and fan unit

Cisco ME 3400EG-2CS chassis (part number ME-3400EG-2CS-A) with two dual-purpose (10/100/1000

and SFP) ports, two SFP uplinks, and an integrated AC power supply

Cisco ME 3400E-24TS chassis (part number ME-3400E-24TS-M) with 24 Ethernet 10/100 ports, two dual-

purpose (10/100/1000 and SFP) uplinks, and two slots for field-replaceable modular power supply and fan unit

Figure 1. Cisco ME 3400E Series

The Cisco ME 3400E Series offers two different Cisco IOS® Software feature images. The METROACCESS image

offers advanced quality of service (QoS), rate limiting, robust multicast control, and comprehensive security

features. In addition, the METROACCESS image includes a rich set of Carrier Ethernet access features including

802.1Q Tunneling, Layer 2 Protocol Tunneling (L2PT), and Flexlink. The METROIPACCESS image adds

advanced Layer 3 features such as support for advanced IP routing protocols, Multi-VPN Routing and Forwarding

Customer Edge (Multi-VRF CE), and Policy Based Routing (PBR).

Page 36: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 2 of 19

The SFP-based Gigabit Ethernet ports accommodate a wide range of 100BASE, 1000BASE, coarse wavelength-

division multiplexing (CWDM), and dense wavelength-division multiplexing (DWDM) SFP transceivers. These

ports also support the Cisco Catalyst® 3560 SFP Interconnect Cable for establishing a low-cost Gigabit Ethernet

point-to-point connection.

Service-Provider-Friendly Hardware

Because Carrier Ethernet access switches are typically deployed in small spaces in office buildings or apartments,

the Cisco ME 3400E Series offers a compact form factor and flexible mounting options. In addition, the Cisco ME

3400E Series has all front-accessed connectors to simplify field installation and troubleshooting. To help ensure

compliance with industry standards, the Cisco ME 3400E Series has obtained both Network Equipment Building

Standards Level 3 (NEBS3) and ETSI certifications.

Industry-Standard Services

Carrier Ethernet is a huge growth area for emerging connectivity services. It is a comparatively simple, cost-

effective, and familiar technology whose migration to the WAN will lead to more flexible network connectivity while

reducing overall IT costs. The Cisco ME 3400E Series is certified to Metro Ethernet Forum (MEF) 9 and 14 to

support industry-standard Layer 2 services and QoS features.

Gigabit Ethernet

With more and more applications demanding higher bandwidth, both enterprise and residential customers want

access speeds greater than 100 Mbps. To address this requirement, the Cisco ME 3400E Series offers wire-

speed Gigabit Ethernet with all the Carrier Ethernet functions. At speeds of 1000 Mbps, Gigabit Ethernet provides

the bandwidth to meet new and evolving network demands, alleviate bottlenecks, and boost performance while

protecting the investment in existing infrastructure.

Carrier Ethernet-Specific Software

The Cisco ME 3400E Series software is designed specifically for the Carrier Ethernet market. Numerous new

features make the Cisco ME 3400E Series the optimal access switch for service providers. Many default behaviors

of the Cisco ME 3400E Series are different from those of traditional Ethernet switches, making the Cisco ME

3400E Series easier to configure, manage, secure, and troubleshoot.

UNI/ENI/NNI

The Cisco ME 3400E Series software introduces the concept of User-Network Interface/Enhanced Network

Interface/Network-Node Interface (UNI/ENI/NNI) for Ethernet access switches. Because the software can identify

the application of each port, it can provide many powerful default behaviors. Table 1 lists some of the primary

behaviors and benefits of UNI/ENI/NNI.

Table 1. UNI/ENI/NNI Default Behaviors

Default Behaviors Benefits

UNI/ENI default: down Ports must be activated by the service provider before customers can receive service.

UNI/ENI default: no local switching Circuit-like behavior protects customers from each other.

UNI/ENI default: configurable control plane security enabled

Control-plane packets ingressing from the UNI/ENI are dropped in hardware to protect against denial-of-service (DoS) attacks by default. Unlike UNI ports, ENI ports give service providers the flexibility to selectively discard or peer with customer’s control plane traffic on a per-port, per-protocol basis for the following Layer 2 protocols: Cisco Discovery Protocol, Link Layer Discovery Protocol (LLDP), Link Aggregation Control Protocol (LACP), Port Aggregation Protocol (PAgP), and Spanning Tree Protocol.

NNI default: up Enables automated configuration of the switch through a Dynamic Host Configuration Protocol (DHCP) or BOOTP server.

Page 37: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 3 of 19

Flexible Deployment Options for Software Features

The Cisco ME 3400E Series offers two different Cisco IOS Software feature images, METROACCESS and

METROIPACCESS, providing cost-effective, “pay-as-you-grow” upgrade options for service providers deploying

multiple services. The service providers do not have to pay for the features they do not need today and still have

the option in the future to receive those features with a simple software upgrade.

Support for multiple software feature images allows service providers to standardize on the Cisco ME 3400E

Series, save on the operating expense of stocking multiple products, simplify training of support technicians, and

alleviate the complication of supporting different products for different services.

Table 2 lists the key features in the Cisco IOS Software images for the Cisco ME 3400E Series.

Table 2. Key Features in Cisco IOS Software Images for Cisco ME 3400E Series

METROACCESS METROIPACCESS

UNI/ENI/NNI 802.1Q Tunneling, L2PT All METROACCESS features plus:

Internet Group Management Protocol (IGMP) Filtering and Throttling

Ethernet OAM (802.1ag, 802.3ah, E-LMI) Static routing

Multicast VLAN Registration (MVR) Y.1731 Fault Management and Performance Monitoring (Delay Measurement)

Multi-VRF CE (VRF-lite)

Advanced QoS Configurable per VLAN MAC Learning PBR

Configurable control plane security Flexlink RIP Versions 1 and 2

Configuration file security Dynamic ARP Inspection, IP Source Guard EIGRP, OSPF, and IS-IS

DHCP snooping Per-Port, Per-VLAN Ingress Policing BGPv4

Private VLAN Link-State Tracking NNI configurable on all ports

Configuration rollback Resilient Ethernet Protocol (REP) Source Specific Multicast

DHCP-based auto configuration and image update

Ethernet IP SLA TWAMP Source Specific Multicast mapping

Configurable Control Plane Queue Assignent Embedded Event Manager Multicast support for VRF (mVRF-Lite)

MAC address learning and aging notifications VRF-aware services (ARP, ping, SNMP, HSRP, uRPF syslog, traceroute, FTP, and TFTP)

Solutions for Next-Generation Business Access Services

The Cisco ME 3400E Series is designed to help service providers provide service availability, service flexbility,

service manageability, and service security for advanced Carrier Ethernet business access.

Service Availability

Increased service availability is a critical requirement for service provider networks because most enterprise

customers expect the same level of availability from Carrier Ethernet as they have from leased-line networks. The

Cisco ME 3400E Series supports redundant field-replacable integrated power supply and fan modules. To quickly

activate and troubleshoot services, the Cisco ME 3400E Series offers traffic loopback capabilities so service

providers can remotely verify and monitor services. Four external alarm inputs allow service providers to respond

quickly to changes in the switch’s environmental condtions before failure occurs.

To further increase service availability on a networkwide level, Cisco ME 3400E offers Flexlink for sub-50-ms

failover, Resilient Ethernet Protocol (REP), Link-State Tracking, IEEE 802.1w Rapid Spanning Tree Protocol

(RSTP), per-VLAN Rapid Spanning Tree Plus (PVRST+), and the Cisco Hot Standby Router Protocol (HSRP).

These capabilities help to create redundant, failsafe topologies. Strong, built-in security in three tiers―network,

Page 38: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 4 of 19

switch, and subscriber – helps prevent the device and the network from succumbing to malicious attacks, thereby

enhancing network uptime.

Resilient Ethernet Protocol (REP) is a Cisco proprietary protocol that provides an alternative to Spanning Tree

Protocol to control network loops, handle link failures, and improve convergence time. REP enables fast and

predicable reconvergence for Layer 2 networks. In addition, REP supports VLAN load balancing to enable efficient

utilization of redundant links.

Service Flexibility

As more enterprises adopt Carrier Ethernet technology, the demand on service providers’ abilities to offer new

services increases. The Cisco ME 3400E Series offers 1:1 VLAN translation which allows end customers the

flexibility of choosing their own internal VLANs without affecting the core service provider’s network. In some

instances, service providers need to provide multiple EPL (Ethernet Private Line) services on a single UNI (User

Network Interface). With the Selective QinQ feature, the Cisco ME 3400E Series helps service providers to offer

multiple Ethernet Virtual Private Line (EVPL) services on a single UNI. To support the need for next-generation

enterprise services, customers are lookings for more QoS functionalities to support differenty types of applicatoins.

To meet the need for ever stringent QoS requirements from customers, the Cisco ME 3400E Series offers 2-rate

3-color policer with byte-level statistics at ingress ports and inner-to-outer CoS mapping to help service providers

offer differentiated services with high profit margins.

Service Manageability

With today’s sophiscated networks, service providers are always looking for ways to reduce operational expenses

(OpEx) and increase profit margins. The Cisco ME 3400E Series provides the following tools to help service

providers simplify the management of their Ethernet services.

Traffic loopback capabilities to help service providers activate and troubleshoot new and existing services without

expensive truck rolls. The “dying gasp” alert for loss of power and four external alarm inputs to detect changes in

remote sites further help service providers to manage the health of their equipment. And an Ethernet management

port provides dedicated access for service providers to monitor and provision the switch.

In addtion, the Cisco ME 3400E Series includes Generic Online Diagnostics (GOLD) and Onboard Failure Logging

(OBFL) to help service providers avoid potential problems before they occur and troubleshoot and diagnose

issues once they happened. With features such as Embedded Event Manager (EEM), Ethernet Operations,

Administration, and Management (OAM), and Time-Domain Reflectometer (TDR), the Cisco ME 3400E Series

provides a comprehensive set of tools to help service providers to manage Ethernet services.

Service Security

As Carrier Ethernet networks expand, it is a challenge to provide the same level of security as other access

technologies. Cisco ME 3400E Series switches provide a comprehensive security solution for Ethernet access

networks by providing service security in three areas: subscriber, switch, and network.

Subscriber security helps create protection among customers. A major concern in using a shared device for

multiple customers is how to prevent customers from affecting each other. The Cisco ME 3400E Series addresses

this concern with several different features. The UNI/NNI feature creates a circuit-like behavior to separate

customers’ traffic from each other. DHCP Snooping, Dynamic ARP Inspection, and IP Source Guard help service

providers identify each customer based on MAC, IP address, and port information to help prevent malicious users

from spoofing fake addresses and launching man-in-the-middle attacks.

Page 39: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 5 of 19

Switch security is about protecting the switch itself from attacks. The Cisco ME 3400 Series offers features to protect

CPU and configuration files from attacks. CPU is a critical component of an Ethernet switch that is responsible for

process-control protocols and routing updates; under DoS attack, the CPU could drop those control packets, resulting

in network outage. Other features such as Configurable Control Plane Security and Storm Control protect the CPU

against malicious attacks. The Port Security feature allows service providers to control the number of MAC addresses

each subscriber is allowed, offering protection against overwhelming the switch memory.

Network security features filter all incoming traffic to help ensure that only valid traffic is allowed through the

switch. Cisco ME 3400E Series switches have features such as access control lists (ACLs) and IEEE 802.1x

authentication to identify the users and packets that are allowed to transmit traffic through the switch.

Table 3 lists these and other key features of the security solution.

Table 3. Key Features for Each Area of Comprehensive Security Solution

Subscriber Security Switch Security Network Security

UNI/ENI default: no local switching Configurable control plane security ACLs

DHCP Snooping and IP Source Guard Storm Control IEEE 802.1x

Dynamic ARP Inspection Port security UNI/ENI default: port down

Private VLAN Configurable per-VLAN MAC learning Configuration file security

Switch Management Options

The Cisco ME 3400E Series offers a superior command-line interface (CLI) for detailed configuration. In addition,

the switches support CiscoWorks and Simple Network Management Protocol (SNMP) for networkwide

management. Service providers can integrate the Cisco ME 3400 Series transparently into their operations

support systems (OSSs) and enable improved flow-through provisioning.

Service providers can also manage the Cisco ME 3400E Series using SNMP Versions 2 and 3. A comprehensive

set of MIBs is provided for service providers to collect traffic information in the Cisco ME 3400E Series.

Ethernet Operations, Administration, Maintenance, and Provisioning

The advent of Ethernet as a metropolitan and wide-area networking technology has accelerated the need for a

new set of operations, administration, maintenance, and provisioning (OAM&P) protocols. Service provider

networks are large and complex with a wide user base, and they often involve different operators that must work

together to provide end-to-end services to enterprise customers. To answer enterprise customer demands, service

providers must reduce the mean time to repair (MTTR) and increase service availability. Ethernet OAM&P features

address these challenges and enable service providers to offer carrier-grade services.

The Cisco ME 3400E Series supports industry-standard OAM&P tools including IEEE 802.1ag Connectivity Fault

Management, IEEE 802.3ah Ethernet First Mile, and Ethernet Local Management Interface (E-LMI) protocol. IEEE

802.1ag tools to monitor and troubleshoot end-to-end Ethernet networks allow service providers to check

connectivity, isolate network issues, and identify customers affected by network issues. E-LMI protocol, developed

by the MEF, enables service providers to communicate service configuration and status information to the

customer-edge device. In addition, the Cisco ME 3400E Series supports the IEEE 802.3ah Ethernet in the First

Mile standard for monitoring, remote failure indication, loopback, and OAM discovery on the link between the

customer equipment and the service provider network.

Page 40: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 6 of 19

Furthermore, the Cisco ME 3400E Series supports the ITU-T standard Y.1731, which provides fault management

and complements the IEEE 802.1ag functionality. In addition, Cisco ME3400E Series also supports Y.1731 Delay

Measurement for performance monitoring.

Applications

Cisco ME 3400E Series switches help service providers offer a portfolio of profitable, differentiated services,

including Layer 2 and Layer 3 VPN services for the ETTB market.

Intelligent Ethernet Demarcation

As Ethernet circuits replace TDM circuits inside of enterprise wiring closets, a replacement for the demarcation

device is also needed. Service providers have traditionally relied on this type of device to separate the

management responsibility. A demarcation device allows service providers to monitor and troubleshoot circuits all

the way into the customer’s wiring closet. The Cisco ME 3400EG-2CS Switch offers the same function for an

Ethernet-based network. With support for industry-standard Ethernet OAM&P features and traffic loopback, the

Cisco ME 3400EG-2CS allows service providers to monitor and troubleshoot Ethernet circuits remotely. These

features greatly reduce operating expense for service providers by reducing the numbers of site visits needed to

troubleshoot network problems. In addition, the Cisco ME 3400EG-2CS provides the same intelligent features

such as QoS, Ethernet security, and Multicast as other switches in the Cisco ME 3400E Series.

Layer 2 VPN Service

Layer 2 VPN services allow customers to connect remote offices together through a service provider network

without requiring private connections. The Cisco ME 3400E Series is suited for Carrier Ethernet access

deployments because it offers features such as 802.1Q Tunneling and L2PT. The Cisco ME 3400E Series helps

service providers offer Layer 2 VPN services to their enterprise or commercial customers (Figure 2). Typically,

these switches are installed in a office building basement serving multiple customers as customer located

equipment (CLE).

Figure 2. Layer 2 VPN Service

Layer 3 VPN Service

Layer 3 VPN is another popular offering from service providers. Its benefits include a single control plane over

different transport technologies, advanced QoS, and high security. With the Multi-VPN Routing and Forwarding

Page 41: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 7 of 19

Customer Edge (Multi-VRF CE) feature, the Cisco ME 3400E Series provides a separate routing-table function for

each customer to help ensure separation of customers’ routing information (Figure 3).

Figure 3. Layer 3 VPN Service

Mobile Backhaul Service

With the explosion of mobile data traffic, service providers need more bandwidth in their mobile networks.

Ethernet, with attributes such as simplicity, scalability, and low cost, has become the mobile backhaul solution that

many service providers have turned to in order to provide the required capacity for data traffic. The Cisco ME

3400E Series provides features such as +24V DC, redundant power supplies, and an extended temperature range

(up to 65°C depending on the model and configuratio n (see Table 9 for more details), which are critical for mobile

backhaul deployments. In addition, the Cisco ME 3400E Series includes Ethernet OAM and traffic loopback, which

help service providers to remotely monitor and troubleshoot traffic at distant cell stations. The Cisco ME 3400E

Series also helps service providers to deliver flexible Layer 2 SLAs with advanced QoS features.

Figure 4. Mobile Backhaul Service

Page 42: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 8 of 19

Key Features and Benefits

Table 4 lists the features and benefits of the Cisco ME 3400E Series.

Table 4. Features and Benefits

Feature Benefit

Next-generation Ethernet access switches for Carrier Ethernet market

All-front access provides ease of deployment and troubleshooting in the field.

Compact form factor allows for deployment in space-limited areas.

Support for dual-speed SFP transceivers (100BASE and 1000BASE) provides flexible downlink/uplink options.

Both AC and DC power options are available.

Software is optimized for Carrier Ethernet access.

Two software feature images help enable support for breadth of services.

Software upgrade options allow service providers to purchase only the features needed today while retaining the option to obtain other features through simple software upgrades.

Upgrade options reduce operating expense by lowering the support costs for different products and by reducing the number of different products needed for sparing.

METROACCESS software feature image is designed for Layer 2 VPN services.

METROIPACCESS software feature image is designed for Layer 3 VPN services.

Service Breadth

Intelligent Ethernet demarcation Industry-standard OAM&P 802.1ag (CFM) feature supports end-to-end network monitoring and troubleshooting. This reduces operating expense by reducing the site visits needed to troubleshoot network problems.

E-LMI enables service providers to communicate service configuration and status information to the customer-edge device. Ethernet in the First Mile OAM&P (802.3ah) provides support for monitoring, remote failure indication, loopback, and OAM discovery on the link between the customer equipment and service provider network.

Traffic loopback allows quick service activation and verification.

Carrier-class redundancy features (Flexlink, RSTP, REP) support both hub-and-spoke and ring networks.

Layer 2 VPN service Standard 802.1Q Tunneling creates a hierarchy of 802.1Q tags, helping service providers use a single VLAN to support customers who have multiple VLANs while preserving customer VLAN IDs and segregating traffic from different customers within the service provider infrastructure.

2-rate 3-color policer allows service providers to provide more flexible control on incoming traffic rate.

1:1 VLAN mapping gives service providers the flexibility to translate customer VLAN ID into a service provider VLAN ID to support overlapping customer VLAN IDs.

Selective QinQ (1:2 VLAN mapping) enables service providers to multiplex multiple services on a single UNI (MEF EVPL for example).

Inner-to-outer CoS value propagation for QinQ helps ensure that customer QoS setting is honored in the service provider network.

L2PT allows for transport of the customer’s control protocols, thereby allowing for transparency across the service provider’s shared infrastructure.

Layer 3 VPN service Multi-VRF CE (VRF-lite) forms virtual packet-forwarding tables by associating one or more Layer 3 interfaces with each VRF, allowing the creation of multiple Layer 3 VPNs on a single Cisco ME 3400 Series switch. Interfaces in a VRF could be either physical, as in an Ethernet port, or logical, as in a VLAN switch virtual interface (SVI), requiring the METROIPACCESS feature image.

IP Multicast support in Multi-VRF CE allows customers to migrate to VRF-lite without affecting application and services that depend on IP Multicast.

VRF-aware services (ARP, ping, SNMP, HSRP, uRPF syslog, traceroute, FTP, and TFTP) help in managing individual VRFs.

Support for multiple IP routing protocols (RIPv1/v2, EIGRP, OSPF, IS-IS, and BGPv4) offers flexible options for peering between customers and service providers.

Page 43: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 9 of 19

Feature Benefit

Availability and Scalability

Superior redundancy for fault backup

Field-replaceable integrated power supply and fan module increases network uptime.

IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) provides rapid spanning-tree convergence independent of spanning-tree timers and offers the benefit of distributed processing.

Per-VLAN Rapid Spanning Tree (PVRST+) allows rapid spanning-tree reconvergence on a per-VLAN spanning-tree basis, without requiring the implementation of spanning-tree instances.

Cisco Hot Standby Router Protocol (HSRP) is supported to create redundant, fail-safe routing topologies.

Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD allow unidirectional links caused by incorrect fiber-optic connections or port faults to be detected and disabled on fiber-optic interfaces.

Flexlink provides fast failover of ports without overhead of control protocols such as the Spanning Tree Protocol.

Switch-port autorecovery (errdisable) automatically attempts to reactivate a link that is disabled because of a network error.

Equal-cost routing provides for load balancing and redundancy.

Bandwidth aggregation up to 8 Gbps through Cisco EtherChannel technology enhances fault tolerance and offers greater aggregated bandwidth between switches and to routers and individual servers.

Link-State Tracking helps accelerate Layer 3 reconvergence by taking UNI down when the associated NNI is down.

Resilient Ethernet Protocol (REP) provides fast Layer 2 reconvergence in a ring network and offers an alternative to Spanning Tree Protocol.

High-performance IP routing Cisco Express Forwarding hardware routing architecture delivers extremely high-performance IP routing.

Basic IP Unicast routing protocols (static and RIP versions 1 and 2) are supported for small-network routing applications.

Advanced IP Unicast routing protocols (OSPF, EIGRP, IS-IS, and BGPv4) are supported for load balancing and constructing scalable LANs.

HSRP provides dynamic load balancing and failover for routed links; up to 32 HSRP links are supported per unit.

Inter-VLAN IP routing provides for full Layer 3 routing between two or more VLANs.

Protocol Independent Multicast (PIM) for IP Multicast routing is supported, including PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), and PIM sparse-dense mode. The Metro IP Access image is required.

Cisco recommends 128 switch virtual interfaces (SVIs). A maximum of 1000 are supported (depending on the number of routes and multicast entries).

IPv6 improves the scalability of IP networks by supporting the growing number of users, applications and services. The functionalities supported include ACLs, DHCP, routing (Unicast routing, RIP, OSPFv3, static routes), MLD snooping, stateless autoconfig, default router preference, HTTP/HTTPS.

Multicast

Efficient multicast distribution Multicast VLAN Registration provides efficient multicast distribution in ring networks by dedicating a single VLAN for multicast traffic, thereby removing duplicate multicast traffic in other VLANs.

PIM-SM provides efficient routing of multicast traffic by establishing distribution trees across WANs.

Source Specific Multicast (SSM) reduces the need for IP Multicast address management and prevents DoS attacks against receivers.

SSM mapping provides a mapping of source to group, which allows listeners to find/connect to multicast sources dynamically, reducing dependencies on the application.

Robust multicast control IGMP Snooping helps enable intelligent management of multicast traffic by examining IGMP messages.

IGMP Fast Leave provides a fast channel-changing capability for IPTV services.

IGMP filtering provides control of groups each user can access.

IGMP Throttling controls the maximum number of multicast groups each user can access.

IGMP Proxy allows users anywhere on a downstream network to join an upstream sourced multicast group.

Page 44: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 10 of 19

Feature Benefit

QoS and Control

Advanced QoS The Cisco Modular QoS CLI provides a modular and highly extensible framework for deploying QoS, by standardizing the CLI and semantics for QoS features across all platforms that are supported by Cisco IOS Software.

2-rate 3-color policer enables service provider to provide more flexible QoS offerings.

Standard 802.1p class of service (CoS) and differentiated services code point (DSCP) field classification are provided, using marking and reclassification on a per-packet basis by source and destination IP address, source and destination MAC address, VLAN ID, or Layer 4 TCP/UDP port number.

Cisco control-plane and data-plane QoS ACLs on all ports help ensure proper marking on a per-packet basis.

Shaped Round Robin (SRR) scheduling helps ensure differential prioritization of packet flows by intelligently servicing the queues.

Weighted Tail Drop (WTD) provides per QoS class congestion avoidance at the queues before a disruption occurs.

Strict priority queuing helps ensure that the highest-priority packets are serviced ahead of all other traffic.

Priority queue rate limiting provides optional protection against lower-priority queue starvation.

Configurable control plane queue assignment allows service providers to assign control plane traffic to specific egress queue.

Prioritization of control plane traffic enables service providers to set QoS markings globally for CPU-generated traffic so these protocol packets will receive priority in the network.

There is no performance penalty for advanced QoS functions.

Advanced traffic control 1:1 VLAN mapping allows service providers to translate same VLAN IDs from different customers into different service provider VLAN IDs to separate customer traffic in the service provider network.

Selective QinQ (1:2 VLAN mapping) gives service providers the ability to multiplex multiple Ethernet Private Line (EPL) services on a single UNI.

Inner-to-outer CoS value propagation for QinQ honors customer QoS setting in the service provider network.

Upstream and downstream traffic flows from the end station or the uplink are easily managed using ingress policing and egress shaping.

Ingress policing provides bandwidth monitoring in increments as low as 8 kbps.

Ingress policing is provided based on CoS, VLAN ID, DSCP, and QoS ACLs (IP ACLs or MAC ACLs) which can include source and destination IP address, source and destination MAC address, Layer 4 TCP/UDP information, or any combination of these fields.

Egress Weighted Fair Queuing helps guarantee the Committed Information Rate (CIR) between traffic flows and queues.

Egress shaping for each queue provides smooth traffic control of available bandwidth.

Egress port rate limiting allows the service provider to control the traffic rate that is transmitted out of the port.

Network Security

Comprehensive security solutions

Subscriber security:

IEEE 802.1x allows dynamic, port-based security by providing user authentication.

IEEE 802.1x with VLAN assignment allows a dynamic VLAN assignment for a specific user regardless of where the user is connected.

IEEE 802.1x and port security are provided to authenticate the port and manage network access for all MAC addresses.

IEEE 802.1x readiness check simplifies deployment by generating a report for end hosts capable of 802.1x.

An absence of local switching behavior provides security and isolation between UNIs, helping ensure that users cannot monitor or access other users’ traffic on the same switch.

DHCP Snooping prevents malicious users from spoofing a DHCP server and sending out bogus addresses. This feature also prevents numerous other attacks such as Address Resolution Protocol (ARP) poisoning.

Dynamic ARP Inspection helps ensure user integrity by preventing malicious users from exploiting the insecure nature of the ARP protocol.

IP Source Guard prevents a malicious user from spoofing or taking over another user’s IP address by creating a binding table between client’s IP and MAC address, port, and VLAN.

Switch security:

Control Plane Security prevents DoS attacks on the CPU.

Configurable control plane security on ENI gives service providers the flexibility to selectively discard or peer with customer’s control plane traffic on a per-port, per-protocol basis.

Secure Shell (SSH) Protocol, Kerberos, and SNMPv3 provide network security by encrypting administrator traffic during Telnet and SNMP sessions. SSH, Kerberos, and the cryptographic version of SNMPv3 require a special cryptographic software image because of U.S. export restrictions.

Port security secures the access to an access or trunk port based on MAC address. After a specific timeframe, the aging feature removes the MAC address from the switch to allow another device to connect to the same port.

Page 45: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 11 of 19

Feature Benefit Multilevel security on the console access prevents unauthorized users from altering the switch configuration.

TACACS+ and RADIUS authentication facilitate centralized control of the switch and restrict unauthorized users from altering the configuration.

Configuration File Security helps ensure that only authenticated users have access to the configuration file.

MAC address learning and aging notifications allow administrators to keep track of subscriber activities.

Network security:

Cisco security VLAN ACLs on all VLANs prevent unauthorized data flows from being bridged within VLANs.

Cisco standard and extended IP security router ACLs define security policies on routed interfaces for control-plane and data-plane traffic.

Port-based ACLs for Layer 2 interfaces allow for application of security policies on individual switch ports.

MAC address notification allows administrators to be notified of users added to or removed from the network.

Network monitoring:

Loopback allows service provider to test end-to-end traffic condition in the network.

Remote Switched Port Analyzer (RSPAN) allows for remote monitoring of the user interface.

Bidirectional data support on the Switched Port Analyzer (SPAN) port allows the Cisco intrusion detection system to take action when an intruder is detected.

Manageability

Superior manageability The Cisco IOS CLI provides a common user interface and command set with all Cisco routers and Cisco Catalyst desktop switches.

Cisco Service Assurance Agent (SAA) provides service-level management throughout the network. IEEE 802.1ag Connectivity Fault Management provides standard support for transport fault management. It

allows for discovery and verification of path for Layer 2 services. Ethernet Local Management Interface enables service providers to communicate service configuration and

status information to the customer-edge device IEEE 802.3ah Ethernet in the First Mile provides standard support for monitoring, remote failure indication, loopback, and OAM discovery on the link between the customer equipment and service provider network.

ITU-T Y.1731 introduces the support for fault management functions, including alarm indication signal (AIS), remote defect indication (RDI) and locked signal (LCK) to detect and signal a failure in the service path.

The Cisco ME 3400E Series supports ITU-T Y.1731 Performance Monitoring function to measure frame delays in the network.

Switching Database Manager templates for Layer 2 and Layer 3 deployment allow administrators to easily optimize memory allocation to the desired features based on deployment-specific requirements.

VLAN trunks can be created from any port, using standards-based 802.1Q tagging. Up to 1005 VLANs per switch and up to 128 spanning-tree instances per switch are supported.

4096 VLAN IDs are supported. RSPAN allows administrators to remotely monitor ports in a Layer 2 switch network from any other switch in

the same network. For enhanced traffic management, monitoring, and analysis, the embedded Remote Monitoring (RMON)

software agent supports four RMON groups (history, statistics, alarms, and events). Layer 2 traceroute eases troubleshooting by identifying the physical path that a packet takes from source to

destination. All nine RMON groups are supported through a SPAN port, permitting traffic monitoring of a single port, a

group of ports, or the entire stack from a single network analyzer or RMON probe. Domain Name System (DNS) provides IP address resolution with user-defined device names. Trivial File Transfer Protocol (TFTP) reduces the cost of administering software upgrades by downloading

from a centralized location. Network Timing Protocol (NTP) provides an accurate and consistent time stamp to all intranet switches. The Cisco ME 3400 Series supports the Cisco CNS 2100 Series Intelligence Engine and SNMP for

networkwide management. Cisco ISC applications help reduce administration and management costs by providing automated resource

management and rapid profile-based provisioning capabilities. Configuration Rollback helps in error recovery by providing the capability to replace the current running

configuration with any saved Cisco IOS configuration file. Embedded Events Manager (EEM) offers the ability to monitor events and take user-defined action when the

monitored events occur or a threshold is reached. Dynamic Host Configuration Protocol (DHCP)-based auto configuration and image update simplifies

management of large number of switches by automatically downloading specified configuration and image. Service Diagnostics automates a set of network diagnostic procedures derived from the vast troubleshooting

experiences of Cisco network experts. These diagnostic tools help customers increase network uptime, reduce time to repair and improve service levels.

Digital optical monitoring (DOM) support enable service providers to perform in-service transceiver monitoring and troubleshooting operations. DOM threshold functions allow the monitoring of real time optical parameters on DOM SFPs and the comparison against factory-reset values, generating alarm and warning thresholds.

Page 46: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 12 of 19

Feature Benefit

CiscoWorks support CiscoWorks network management software provides management capabilities on a per-port and per-switch basis, providing a common management interface for Cisco routers, switches, and hubs.

SNMP Versions 1, 2c, and 3 and Telnet provide comprehensive in-band management, and a CLI-based management console provides detailed out-of-band management.

Cisco Discovery Protocol Versions 1 and 2 help enable automatic switch discovery for a CiscoWorks network management station.

CiscoWorks 2000 LAN Management Solution is supported.

Product Specifications

Table 5 lists product specifications for Cisco ME 3400E Series Ethernet Access Switches.

Table 5. Product Specifications

Description Specification

Performance Forwarding bandwidth: Cisco ME 3400EG-12CS AC or DC: 32 Gbps Cisco ME 3400EG-2CS AC: 8 Gbps Cisco ME 3400E-24TS, AC or DC: 8 Gbps

Forwarding rate: Cisco ME 3400EG-12CS, AC or DC: 26 mpps Cisco ME 3400EG-2CS AC: 6.5 mpps Cisco ME 3400E-24TS, AC or DC: 6.5 mpps

128 -MB DRAM and 32 MB flash memory

Configurable up to 8000 MAC addresses

Configurable up to 5000 unicast routes

Configurable up to 1000 IGMP groups and multicast routes

Configurable maximum transmission unit (MTU) of up to 9000 bytes, for bridging on Gigabit Ethernet ports, and up to 1998 bytes for bridging and routing on Fast Ethernet ports

Connectors and cabling 10/100 Ports:

10/100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 unshielded twisted pair (UTP) cabling

SFP Ports:

1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling, 10/100/1000BASE-T operation in host systems with SGMII interface

100BASE-FX and -LX: Duplex LC receptacle fiber connectors (multimode and single-mode)

100BASE-BX: Single-fiber LC receptacle connector (single-mode fiber)

1000BASE-EX: Single Mode Fiber with DOM support

100BASE-EX: SFP module for 100 Mb port, 1310 nm wavelength, 40 km over single-mode fiber

100BASE-ZX: SFP module for 100 Mb port, 1550 nm wavelength, 80 km over single-mode fiber

1000BASE-BX: Single-fiber LC receptacle connector (single-mode fiber)

1000BASE-SX, -LX/LH, and -ZX and CWDM and DWDM: Duplex LC receptacle fiber connectors (multimode and single-mode fiber)

Cisco Catalyst 3560 SFP Interconnect Cable

Management console port: RJ45-to-DB9 cable for PC connections

Indicators Per-port status LEDs: Link integrity, port disabled, and activity indications

System-status LED

Dimensions (H x W x D) Cisco ME 3400EG-12CS-M,: 1.75 x 17.5 x 12.0 in. (4.45 x 44.5 x 30.5 cm)

Cisco ME 3400EG-12CS-M with AC or DC: 1.75 x 17.5 x 12.5 in. (4.45 x 44.5 x 31.8 cm)

Cisco ME 3400EG-2CS AC: 1.73 x 10.6 x 7.2 in. (4.4 x 26.9 x 18.3 cm)

Cisco ME 3400E-24TS-M: 1.75 x 17.5 x 9.3 in. (4.45 x 44.5 x 23.6 cm)

Cisco ME 3400E-24TS-M with AC or DC: 1.75 x 17.5 x 9.8 in. (4.45 x 44.5 x 24.9 cm)

Page 47: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 13 of 19

Description Specification

Weight Cisco ME 3400EG-12CS-M: 8.5 lb (3.9 kg)

Cisco ME 3400EG-2CS AC: 3.4 lb (1.5 kg)

Cisco ME 3400E-24TS-M: 6.4 lb (2.9 kg)

Cisco ME 3400E AC field-replaceable unit with two integrated fans: 1.7 lb (0.77 kg)

Cisco ME 3400E DC field-replaceable unit with two integrated fans: 1.8 lb (0.82 kg)

Cisco ME 3400E field-replaceable unit slot cover: 0.3 lb (0.14 kg)

Mean time between failure (MTBF)

Cisco ME 3400EG-12CS with one AC or one DC: 196,391 hours

Cisco ME 3400EG-2CS AC: 526,490 hours

Cisco ME 3400E-24TS with one AC or one DC: 245,917 hours

Power Specifications

Table 6 gives power specifications for the Cisco ME 3400E Series.

Table 6. Power Specifications

Description Specification

Power consumption Cisco ME 3400EG-12CS-M, one AC: 50W (typical), 80W (maximum), 171 Btus per hour (typical)

Cisco ME 3400EG-12CS-M, two AC: 60W (typical), 95W (maximum), 205 Btus per hour (typical)

Cisco ME 3400EG-12CS-M, one DC: 60W (typical), 99W (maximum), 205 Btus per hour (typical)

Cisco ME 3400EG-12CS-M, two DC: 70W (typical), 115W (maximum), 239 Btus per hour (typical)

Cisco ME 3400EG-2CS AC: 22W (typical), 30W (maximum), 75 Btus per hour (typical)

Cisco ME 3400E-24TS-M, one AC: 36W (typical), 40W (maximum), 123 Btus per hour (typical)

Cisco ME 3400E-24TS-M, two AC: 38W (typical), 54W (maximum), 130 Btus per hour (typical)

Cisco ME 3400E-24TS-M, one DC: 38W (typical), 48W (maximum), 130 Btus per hour (typical)

Cisco ME 3400E-24TS-M, two DC: 48W (typical), 72W (maximum), 164 Btus per hour (typical)

AC input voltage and frequency

Cisco ME340X-PWR- AC: 100 to 240 VAC (+/- 10% autoranging), 1.5 to 0.7A, 50 to 60 Hz

DC input voltages Cisco ME340X-PWR- DC: 18 to 72 VDC, 8 to 4A (18 to 36V), 4 to 2A (36 to 72V)

Management and Standards

Table 7 provides management and standards support information for the Cisco ME 3400E Series.

Table 7. Management and Standards

Description Specification

Management BRIDGE-MIB (RFC1493)

BGP4-MIB (RFC1657)

CISCO-CABLE-DIAG-MIB

CISCO-BULK-FILE-MIB

CISCO-CDP-MIB

CISCO-CONFIG-COPY-MIB

CISCO-CONF-MAN-MIB

CISCO-DATA-COLLECTION-MIB

CISCO-ENVMON-MIB

CISCO-ERR-DISABLE-MIB

CISCO-ETHERNET-ACCESS-MIB

CISCO-FLASH-MIB

CISCO-FTP-CLIENT-MIB

CISCO-HSRP-MIB

CISCO-HSRP-EXT-MIB

CISCO-IETF-DOT3-OAM-MIB

CISCO-IGMP-FILTER-MIB

CISCO-IPLSA-ETHERNET-MIB

CISCO-UDLDP-MIB

CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB

CISCO-VLAN-MEMBERSHIP-MIB

ENTITY-MIB (RFC2737)

ETHERLIKE-MIB

IEEE8021-PEA-MIB

IEEE8023-LAG-MIB

IF-MIB (RFC 1573)

IGMP-MIB

IPMROUTE-MIB

OLD-CISCO-CHASSIS-MIB

OLD-CISCO-FLASH-MIB

OLD-CISCO-INTERFACES-MIB

OLD-CISCO-IP-MIB

OLD-CISCO-SYS-MIB

OLD-CISCO-TCP-MIB

OLD-CISCO-TS-MIB

OSPF-MIB (RFC 1253)

Page 48: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 14 of 19

Description Specification CISCO-PAGP-MIB

CISCO-PAE-MIB

CISCO-PING-MIB

CISCO-PRIVATE-VLAN-MIB

CISCO-PROCESS-MIB

CISCO-PORT-QOS-MIB

CISCO-PORT-SECURITY-MIB

CISCO-PORT-STORM-CONTROL-MIB

CISCO-IMAGE-MIB

CISCO-LAG-MIB

CISCO-L2L3-INTERFACE-CONFIG-MIB

CISCO-MAC-NOTIFICATION-MIB

CISCO-MEMORY-POOL-MIB

CISCO-RTTMON-MIB

CISCO-STACK-MIB

CISCO-STP-EXTENSIONS-MIB

CISCO-SYSLOG-MIB

CISCO-TCP-MIB

PIM-MIB

RFC1213-MIB (MIB-II)

RMON-MIB (RFC 1757)

RMON2-MIB (RFC 2021)

SNMP-FRAMEWORK-MIB (RFC2571)

SNMP-MPD-MIB (RFC 2572)

SNMP-NOTIFICATION-MIB (RFC 2573)

SNMP-TARGET-MIB (RFC 2573)

SNMPv2-MIB (RFC 1907)

SNMP-USM-MIB (SNMP-USER-BASED-SM-MIB) (RFC2574)

SNMP-VACM-MIB (SNMP-VIEW-BASED-ACM-MIB) (RFC2575)

TCP-MIB (RFC 2012)

UDP-MIB (RFC 2013)

Standards and protocols IEEE 802.1s

IEEE 802.1w

IEEE 802.1x

IEEE 802.3ad

IEEE 802.3ah

IEEE 802.1ag

IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports

IEEE 802.1D Spanning Tree Protocol

IEEE 802.1p CoS classification

IEEE 802.1Q VLAN

IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-T

IEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-X

IP routing: Static, RIP versions 1 and 2, EIGRP, OSPF, BGPv4, PIM-SM, and PIM-DM (metro IP access only)

IPv6: MLD Snooping v1 and v2

IPv6: RIP, OSPFv3, static routes

Management: SNMP versions 1, 2, and 3

Safety and Compliance

Table 8 gives safety and compliance information for the Cisco ME 3400 Series.

Table 8. Safety and Compliance

Type Standards

Electromagnetic emissions compliance

FCC Part 15 Class A

EN 55022 Class A (CISPR22 Class A)

EN 55024

EN 300 386

GR-1089 CORE Issue 4

GR-63 CORE Issue 3

VCCI Class A

AS/NZS 3548 Class A or AS/NZS CISPR22 Class A

KCC

CE Marking

Page 49: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 15 of 19

Type Standards

Safety UL 60950-1, First Edition

CUL to CAN/CSA 22.2 No.60950-1, First Edition

TUV/GS to EN 60950-1

CB report/certificate to IEC 60950 with all country deviations

NOM to NOM-019-SCFI (through distributors)

CE Marking

NEBS GR-63-CORE and GR-1089-CORE: Level 3, Type 2

CLEI Coding

ETSI EN 300 019: Storage Class 1.2, Transportation Class 2.3, In-Use Class 3.2

Noise specifications Cisco Office Product Specification: 48 dBA (sound pressure) 4.8 bels (sound power)

EN 300 753

Operating environment Temperature: 0 to 65ºC (See table 9 for more details on model and configuration requirements. Temperature versus altitude curve follows NEBS specifications)

Altitude: Up to 13,000 ft (4000m)

Relative humidity: 10 to 95% noncondensing

Storage environment Temperature: –40 to 70ºC

Altitude: 15,000 ft (4570 m)

Table 9 gives operating termpature information for the Cisco ME 3400E Series. Temperature range is dependent

on the SFPs used and the number of field replaceable units operating in the switch.

Table 9. ME3400E Series Temperature Range

Operating Temperature 0ºC to 55ºC 0ºC to 60ºC 0ºC to 65ºC

PID

ME-3400EG-2CS-A

ME-3400E-24TS-M with 1 FRU

ME-3400EG-12CS-M with 1 FRU

ME-3400EG-2CS-A

ME-3400E-24TS-M with 1 FRU

ME-3400EG-12CS-M with 1 FRU

ME-3400EG-2CS-A

ME-3400E-24TS-M with 2 FRUs

ME-3400EG-12CS-M with 2 FRUs

100M SFP

GLC-FE-100FX Yes Yes Yes Yes Yes Yes No Yes Yes

GLC-FE-100LX Yes Yes Yes Yes Yes Yes No Yes Yes

GLC-FE-100EX Yes Yes Yes Yes Yes Yes No Yes Yes

GLC-FE-100ZX Yes Yes Yes Yes Yes Yes No Yes Yes

GLC-FE-100BX-D Yes Yes Yes Yes Yes Yes No Yes Yes

GLC-FE-100BX-U Yes Yes Yes Yes Yes Yes No Yes Yes

1000M SFP

GLC-SX-MM Yes Yes Yes No Yes Yes No No No

GLC-LH-SM Yes Yes Yes No Yes Yes No No No

GLC-ZX-SM Yes Yes Yes No Yes Yes No No No

GLC-BX-D Yes Yes Yes No Yes Yes No No No

GLC-BX-U Yes Yes Yes No Yes Yes No No No

GLC-T Yes Yes Yes No Yes Yes No No No

CWDM-xxxx-SFP Yes Yes Yes No Yes Yes No No No

DWDM-xxxx-SFP Yes Yes Yes No Yes Yes No No No

SFP-GE-S Yes Yes Yes Yes Yes Yes No Yes Yes

SFP-GE-L Yes Yes Yes Yes Yes Yes No Yes Yes

SFP-GE-T Yes Yes Yes Yes Yes Yes No Yes Yes

Page 50: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 16 of 19

Operating Temperature 0ºC to 55ºC 0ºC to 60ºC 0ºC to 65ºC

PID

ME-3400EG-2CS-A

ME-3400E-24TS-M with 1 FRU

ME-3400EG-12CS-M with 1 FRU

ME-3400EG-2CS-A

ME-3400E-24TS-M with 1 FRU

ME-3400EG-12CS-M with 1 FRU

ME-3400EG-2CS-A

ME-3400E-24TS-M with 2 FRUs

ME-3400EG-12CS-M with 2 FRUs

CAB-SFP-50CM Yes Yes Yes Yes Yes Yes No Yes Yes

No SFP Installed Yes Yes Yes Yes Yes Yes No Yes Yes

Ordering Information

Table 10 lists the ordering information for the Cisco ME 3400E Series. To place an order, visit the Cisco Ordering

Home Page at: http://www.cisco.com/en/US/ordering.

Table 10. Ordering Information

Part Number Description

ME-3400EG-12CS-M 12 dual-purpose (10/100/1000 and SFP) ports

4 SFP-based Gigabit Ethernet and 100BASE-X ports

Slots for field-replaceable power supplies and fan modules

Ethernet management console

4 external alarm input contacts

26-mpps forwarding rate

1-RU multilayer switch

Gigabit Ethernet access switch for the Carrier Ethernet market

2 Cisco IOS Software feature image options (METROACCESS and METROIPACCESS)

ME-3400EG-2CS-A 2 dual-purpose (10/100/1000 and SFP) ports

2 SFP-based Gigabit Ethernet and 100BASE-X ports

One fixed AC power supply

Ethernet management console

4 external alarm input contacts

6.5-mpps forwarding rate

1-RU small form-factor multilayer switch

Intelligent Ethernet demarcation switch

2 Cisco IOS Software feature image options (METROACCESS and METROIPACCESS)

ME-3400E-24TS-M 24 Ethernet 10/100 ports

2 SFP-based Gigabit Ethernet and 10/100/1000 dual-purpose ports

Slots for field-replaceable power supplies and fan modules

Ethernet management console

4 external alarm input contacts

6.5-mpps forwarding rate

1-RU multilayer switch

Ethernet access switch for Carrier Ethernet market

2 Cisco IOS Software feature image options (METROACCESS and METROIPACCESS)

ME34X-PWR-AC AC power supply and fan module for ME-3400E-24TS-M and ME-3400EG-12CS-M

ME34X-PWR-DC DC power supply and fan module for ME-3400E-24TS-M and ME-3400EG-12CS-M

S340XA-12244EY Cisco ME 3400E Series METROACCESS software feature image

Enhanced Layer 2 feature images targeted for premium triple-play services and Layer 2 VPN services

Advanced Layer 2 Tunneling: 802.1q tunneling and L2PT

Industry-standard Layer 2 management: 802.1ag (CFM), 802.3ah (EFM), and E-LMI

Fast convergence: Flexlink, Link-State Tracking, Resilient Ethernet Protocol

S340XI-12244EY Layer 3 feature images targeted for Layer 3 VPN services

IP routing (RIP versions 1 and 2, EIGRP, OSFP, IS-IS, and BGPv4)

Secured Layer 3: Multi-VRF CE

Page 51: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 17 of 19

Part Number Description Enhanced routing: Policy Based Routing

CD-ME3400-A2I= METROIPACCESS image upgrade kit for Cisco ME 3400 Series Switches with METROACCESS image

R-CD-ME3400-A2I= E-delivery METROIPACCESS image upgrade kit for Cisco ME 3400 Series Switches with METROACCESS image

RCKMNT-1RU= Spare rack-mount kit for the Cisco ME 3400EG-12CS-M and Cisco ME 3400E-24TS-M

RCKMNT-REC-1RU= 1-RU recessed rack-mount kit for the Cisco ME 3400EG-12CS-M and Cisco ME 3400E-24TS-M

RCKMNT-ETSI-1RU= ETSI rack-mount kit for Cisco ME 3400EG-12CS-M and Cisco ME 3400E-24TS-M

RCKMNT-19IN-1RU= 19-in. NEBS rack-mount kit for all the Cisco ME3400 Series products, except the Cisco ME 3400EG-2CS

RCKMNT-19-CMPCT= 19-in. NEBS rack-mount kit for the Cisco ME 3400EG-2CS

RCKMNT-23IN-1RU= 23-in. NEBS rack-mount kit for Cisco ME 3400EG-12CS-M and Cisco ME 3400E-24TS-M

RCKMNT-23-CMPCT= 23-in. NEBS rack-mount kit for the Cisco ME 3400EG-2CS

GLC-LH-SM= Gigabit Ethernet SFP, LC connector, and LH transceiver

GLC-LH-SMD Gigabit Ethernet SFP, LC connector, and LH transceiver

GLC-SX-MM= Gigabit Ethernet SFP, LC connector, and SX transceiver

GLC-SX-MMD Gigabit Ethernet SFP, LC connector, and SX transceiver

GLC-ZX-SM= Gigabit Ethernet SFP, LC connector, and ZX transceiver

GLC-T= Gigabit Ethernet SFP, RJ-45 connector, and 10/100/1000BASE-T transceiver

GLC-BX-D= 1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX/1310-nm RX wavelength

GLC-BX-U= 1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX/1490-nm RX wavelength

GLC-EX-SMD= 1000BASE-EX SFP

GLC-FE-100FX= 100BASE-FX SFP for Fast Ethernet port

GLC-FE-100LX= 100BASE-LX SFP for Fast Ethernet port

GLC-FE-100EX= 100BASE-EX SFP for Fast Ethernet port

GLC-FE-100ZX= 100BASE-ZX SFP for Fast Ethernet port

GLC-FE-100BX-U= 100BASE-BX10-U SFP

GLC-FE-100BX-D= 100BASE-BX10-D SFP

GLE-GE-100FX= 100BASE-FX (multimode fiber) (works in “multispeed” Gigabit Ethernet SFP ports of other Cisco platforms such as the Cisco Catalyst 3560, Catalyst 3750 [non-metro], and Catalyst 2970 Series)

GLC-FE-100FX24 24 units of GLC-FE-100FX

GLC-FE-100FX48 48 units of GLC-FE-100FX

GLC-FE-100LX48 48 units of GLC-FE-100LX

GLC-FE-100BX-D48 48 units of GLC-FE-100BX-D

SFP-GE-S= 1000BASE-SX SFP (DOM)

SFP-GE-L= 1000BASE-LX/LH SFP (DOM)

CWDM-SFP-1470= Cisco CWDM SFP, 1470 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (gray)

CWDM-SFP-1490= Cisco CWDM SFP, 1490 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (violet)

CWDM-SFP-1510= Cisco CWDM SFP, 1510 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (blue)

CWDM-SFP-1530= Cisco CWDM SFP, 1530 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (green)

CWDM-SFP-1550= Cisco CWDM SFP, 1550 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (yellow)

CWDM-SFP-1570= Cisco CWDM SFP, 1570 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (orange)

CWDM-SFP-1590= Cisco CWDM SFP, 1590 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (red)

CWDM-SFP-1610= Cisco CWDM SFP, 1610 nm; Gigabit Ethernet and 1-/2-GB Fibre Channel (brown)

DWDM-SFP-6061= Cisco DWDM SFP 1560.61 nm (100 GHz ITU grid)

DWDM-SFP-5979= Cisco DWDM SFP 1559.79 nm (100 GHz ITU grid)

DWDM-SFP-5898= Cisco DWDM SFP 1558.98 nm (100 GHz ITU grid)

Page 52: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 18 of 19

Part Number Description

DWDM-SFP-5817= Cisco DWDM SFP 1558.17 nm (100 GHz ITU grid)

DWDM-SFP-5655= Cisco DWDM SFP 1556.55 nm (100 GHz ITU grid)

DWDM-SFP-5575= Cisco DWDM SFP 1555.75 nm (100 GHz ITU grid)

DWDM-SFP-5494= Cisco DWDM SFP 1554.94 nm (100 GHz ITU grid)

DWDM-SFP-5413= Cisco DWDM SFP 1554.13 nm (100 GHz ITU grid)

DWDM-SFP-5252= Cisco DWDM SFP 1552.52 nm (100 GHz ITU grid)

DWDM-SFP-5172= Cisco DWDM SFP 1551.72 nm (100 GHz ITU grid)

DWDM-SFP-5092= Cisco DWDM SFP 1550.92 nm (100 GHz ITU grid)

DWDM-SFP-5012= Cisco DWDM SFP 1550.12 nm (100 GHz ITU grid)

DWDM-SFP-4851= Cisco DWDM SFP 1548.51 nm (100 GHz ITU grid)

DWDM-SFP-4772= Cisco DWDM SFP 1547.72 nm (100 GHz ITU grid)

DWDM-SFP-4692= Cisco DWDM SFP 1546.92 nm (100 GHz ITU grid)

DWDM-SFP-4612= Cisco DWDM SFP 1546.12 nm (100 GHz ITU grid)

DWDM-SFP-4453= Cisco DWDM SFP 1544.53 nm (100 GHz ITU grid)

DWDM-SFP-4373= Cisco DWDM SFP 1543.73 nm (100 GHz ITU grid)

DWDM-SFP-4294= Cisco DWDM SFP 1542.94 nm (100 GHz ITU grid)

DWDM-SFP-4214= Cisco DWDM SFP 1542.14 nm (100 GHz ITU grid)

DWDM-SFP-4056= Cisco DWDM SFP 1540.56 nm (100 GHz ITU grid)

DWDM-SFP-3977= Cisco DWDM SFP 1539.77 nm (100 GHz ITU grid)

DWDM-SFP-3898= Cisco DWDM SFP 1538.98 nm (100 GHz ITU grid)

DWDM-SFP-3819= Cisco DWDM SFP 1538.19 nm (100 GHz ITU grid)

DWDM-SFP-3661= Cisco DWDM SFP 1536.61 nm (100 GHz ITU grid)

DWDM-SFP-3582= Cisco DWDM SFP 1535.82 nm (100 GHz ITU grid)

DWDM-SFP-3504= Cisco DWDM SFP 1535.04 nm (100 GHz ITU grid)

DWDM-SFP-3425= Cisco DWDM SFP 1534.25 nm (100 GHz ITU grid)

DWDM-SFP-3268= Cisco DWDM SFP 1532.68 nm (100 GHz ITU grid)

DWDM-SFP-3190= 1000BASE-DWDM 1531.90 nm (100 GHz ITU grid)

DWDM-SFP-3112= 1000BASE-DWDM 1531.12 nm (100 GHz ITU grid)

DWDM-SFP-3033= Cisco DWDM SFP 1530.33 nm (100 GHz ITU grid)

CSS5-CABLX-LCSC= Cisco CSS 11500 Series Content Services Switch, 10m single-mode fiber, LX LC-to-SC connectors

CSS5-CABSX-LC= Cisco CSS 11500 10m multimode fiber, SX LC connectors

CSS5-CABSX-LCSC= Cisco CSS 11500 10m multimode fiber, SX LC-to-SC connectors

CAB-SFP-50CM= Cisco Catalyst 3560 SFP Interconnect Cable (50 cm)

CAB-SM-LCSC-1M 1m single-mode fiber, LC-to-SC connectors

CAB-SM-LCSC-5M 5m single-mode fiber, LC-to-SC connectors

CAB-MCP-LC= Mode-conditioning patch cable; LC connector

Service and Support

Cisco offers a wide range of services programs to accelerate customer success. These innovative services programs

are delivered through a unique combination of people, processes, tools, and partners, resulting in high levels of

customer satisfaction. Cisco services help you protect your network investment, optimize network operations, and

prepare your network for new applications to extend network intelligence and the power of your business. For more

information about Cisco services, refer to Cisco Technical Support Services or Cisco Advanced Services.

Page 53: Product Catalogue for Operation Spares

© 2012 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 19 of 19

Cisco is committed to minimizing your total cost of ownership. Cisco offers a portfolio of technical support services to

help ensure that Cisco products operate efficiently, remain highly available, and benefit from the most up-to-date

system software. The services and support programs described in Table 11 are available as part of the Cisco Carrier

Ethernet Switching Service and Support solution, and are available directly from Cisco and through resellers.

Table 11. Service and Support

Service and Support Features Benefits

Advanced Services

Cisco Total Implementation Solutions (TIS), available directly from Cisco

Cisco Packaged TIS, available through resellers

Project management

Site survey, configuration, and deployment

Installation, text, and cutover

Training

Major moves, adds, and changes

Design review and product staging

Supplement existing staff

Help ensure functions meet needs

Mitigate risk

Cisco SP Base Support and Service Provider-Based Onsite Support, available directly from Cisco

Cisco Packaged Service Provider-Based Support, available through resellers

24-hour access to software updates

Web access to technical repositories

Telephone support through the Cisco Technical Assistance Center (TAC)

Advance Replacement of hardware parts

Facilitate proactive or expedited problem resolution

Lower total cost of ownership by taking advantage of Cisco expertise and knowledge

Minimize network downtime

Printed in USA C78-495220-06 11/12

Page 54: Product Catalogue for Operation Spares

11.0 Nexans N423.540N

Page 55: Product Catalogue for Operation Spares

ContactCabling SolutionsPhone: +32 2 363 38 [email protected]

European Mounting Hardware for LANmarkLANmark EU style angled 45 x 45 module 2 Snap-In white

Generated 10/23/13 - http://www.nexans.be Page 1 / 2All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of

Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

Nexans ref.: N423.540N

Kit of 45x45 back module with Snap-In front module•Accomodates 2 Snap-In connectors•Suitable for both copper and fibre•Installation benefit thanks to angled design•Colour white (RAL 9010)•Also available in ivory (RAL 9002)•Also available in 1 port version (N423.520)•

StandardsInternational Manufacturer specification

Description

ApplicationThe European style 45x45 angled module can accommodate 2 LANmark Snap-In connectors.

It is also designed to hold fibre Snap-In adaptors, LC or SC, duplex or simplex.•For detailed information on Nexans Snap-In connectors, please refer to the corresponding datasheets.

GuaranteesThe plastic material is UL 94V0•

InstallationThe Snap-In connectors easily clip in the shuttered front module, which then is mounted into the 45x45 module without the need for any tools.

Thanks to the angled position of the connectors, the minimum bend radius of the cables is maintained, even in situations where depth is restricted.

The inclined faceplate also protects the patch cords and prevents dust entry when the shutters are left open.

The 45x45 angled module fits into a wide range of international frames, surface mount boxes and trunking.

Features:Labelling window for easy management and port identification.•Compatible with all Nexans Snap-In format connectors and adaptors•Compatible with all Nexans 45x45 structural hardware•Allows vertical and horizontal mounting in cable ducts•Side clips can be easily removed if necessary•Shuttered front module can be inserted in 2 different positions•

Labelling window•Shutters•

Included in the kit:

Optional:

Page 56: Product Catalogue for Operation Spares

ContactCabling SolutionsPhone: +32 2 363 38 [email protected]

European Mounting Hardware for LANmarkLANmark EU style angled 45 x 45 module 2 Snap-In white

Generated 10/23/13 - http://www.nexans.be Page 2 / 2All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of

Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.

Coloured shutters (bag of 100):

red - ref. N421.701RED•blue - ref. N421.701BLU•green - ref. N421.701GRE•yellow - ref. N421.701YEL•orange - ref. N421.701ORA•dark grey - ref. N421.701DGR•black - ref. N421.701BLA•

Characteristics

Construction characteristicsColour White RAL 9010

Dimensional characteristicsDepth 36 mmWidth 45 mmHeight 45 mm

Page 57: Product Catalogue for Operation Spares

12.0 AUTELDAC 4

Page 58: Product Catalogue for Operation Spares

GAI-Tronics Telephony Auteldac 4

ATEX Approved Hazardous Area Telephone

Ex II 2 GD & Ex II 2 G ATEX Certified telephone for Gas and Dust

Zone 1 & 2, Zone 21 & 22 Compliant

(R&TTE Directive 1999/5/EC and ATEX Product Directive 94/9/EC)

IEC Ex certified GOST-R & INMETRO Approved for Gas Fully compliant with TBR21 / TBR38 Full keypad with 3 programmable

memory buttons, or CB variant Headset Option 90dB sounder (adjustable) Secondary beacon / external sounder

actuator Robust and weather resistant (IP66

with curly cord, IP54 with steel cord) Industry standard robust handset c/w

curly cord or armoured stainless steel Noise cancelling versions available Dual purpose design for wall or desk

mounting, simple installation

The Auteldac 4 (A4) telephone has secured ATEX and IEC approval to provide a tough, weather resistant unit, built to withstand arduous industrial atmospheres and environmental extremes.

Certified for safe operation in hazardous areas, the Auteldac 4 body is made from carbon loaded glass filled polyester to eliminate rust and corrosion.

The elimination of moving parts maintains a high level of reliability to industrial and weather resistant telephones.

Features such as 'electronic on-hook sensing' and 'electronic tone ringer' enable an enclosure protection up to IP66. Should the handset be left off-hook, the A4 will automatically revert to on-hook state after a period of 6-8 minutes (this option can be disabled).

Auteldac 4 telephones come complete with an integral ringer with volume control and secondary beacon / external sounder actuator as standard. An inductive coupler is fitted to aid the hard of hearing. For hands-free telephone use, the Auteldac 4 has the option of a headset.

Connectivity: Standard Analogue The standard analogue unit provides basic telephone functions and can be connected to any standard two-wire telephone line, including FXS ports, analogue PABX lines and PSTN.

Options: The handset has a choice of armoured stainless steel or curly cords.

Keypad Options: 18 button Full Keypad Included in the 18 button version, are 3 direct dial buttons for fast one touch dialling of pre-stored numbers or accessing low cost call facilities. Includes: M1- M3 Memory buttons, S ‘Store’, R ‘Recall’, LR ‘Last number redial’

0 button CB This can be used to initiate a PABX 'hotline' or lift handset and wait for reply, where the PABX does the call routing/dialling. Autodial on handset lift also available.

Page 59: Product Catalogue for Operation Spares

GAI-Tronics Telephony Auteldac 4

ATEX Approved Hazardous Area Telephone

GAI-Tronics® - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - [email protected] - www.gai-tronics.co.uk GAI-Tronics® (Corporate) - USA - Tel: +1(610) 777 1374 - Toll Free: 800 492 1212 - Fax: +1(610) 796 5954 - www.gai-tronics.com GAI-Tronics® S.r.l - Italy - Tel: +39 02 48601 460 - Fax: +39 02 4585 625 - www.gai-tronics.co.uk GAI-Tronics® - Malaysia - Tel: +60 3 8945 4035 - Fax: +60 3 8945 4675 - www.gai-tronics.co.uk GAI-Tronics® Austdac - Australia - Tel: 011 61 28 851 5000 - Fax: 011 61 29 899 2490 - www.austdac.com.au An ISO 9001, ISO 14001, OHSAS 18001 Registered Company The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.

B169-2-0711B/CN336306-001

TECHNICAL SPECIFICATIONS (please refer to technical manual for full product details) Enclosure: Carbon loaded glass-filled polyester (colour: black) Surface resistance: <109 ohms Handset: Conductively coated polycarbonate handset with coiled cord or stainless steel spiral cord. Noise cancelling options. Extended cord lengths available. Keypad: Weathersealed tactile digital keypad Hookswitch: Electronic with no mechanical moving parts Weather Ingress protection: IP66 curly cord, IP54 steel cord Ringing: Shrill warble tone >90 dBA @ 1 metre typical. Internal volume control. Power Supply: Drawn from telephone line Integral Ring Detector: Contact closure following the ringing cadence, rated at 250Vac, 5A. Isolated hookswitch sensor: Additional contact rated at 250Vac, 150mA Parallel Terminal Block: Duplicated line terminals allows connection to a parallel device without an additional junction box. Time Out: Enforces a fixed call maximum time limit to 6-8 minutes from lifting of the handset. User selectable. Dialling system: LD or DTMF (switchable) Recall Button: Internally switchable from Earth Loop Recall (600ms pulse) and Timed Break Recall 98ms, 250ms or 604ms. Certified Operating Temperature: -20° C up to +55° C (-40° C to +50° C for GOST-R) Relative Humidity: Up to 95% (non-condensing) Weight: approx. 3.1 kg

APPROVALS This mark indicates compliance with the following

directives; R&TTE Directive 1999/5/EC, ATEX Product Directive 94/9/EC, Tested to TBR21 / TBR38 The GAI-Tronics Quality Management System has been approved by LRQA to ISO9001:2008 & ISO 14001:2004 Certificate No. 861888 and OHSAS 18001:2007 Certificate No. 4004472 Telephone compliance Baseefa03ATEX0617

II 2 GD (curly cord, no headset) Ex ibD tb IIIC T180°C, Ex e ib mb IIC T4 Gb (-20°C to +55°C) T5 Gb (-20°C to +50°C)

II 2 G (steel cord and/or headset versions) Ex e ib mb IIC T4 Gb (-20°C to +55°C) T5 Gb (-20°C to +50°C) IECEx BAS 05.0060 Ex e mb ib IIC T4 (-20°C to +50°C), Ex e mb ib IIC T5 (-20°C to +50°C) GOST-R Approval (Russia) РОСС GB.ГБ06.В00825 (-40°C to +50°C) INMETRO Approval (Brazil) CEPEL-EX-2016/11 BR-Ex e ib mb IIC T5 Gb (-20°C to +50°C) BR-Ex e ib mb IIC T4 Gb (-20°C to +55°C) Headset compliance

II 2 G EEx ib IIC T4 (-20°C to +40°C) TUV03ATEX2124 GOST-R Approval РОСС GB.ГБ06.В00825 (-40°C to +40°C)

DIMENSIONS:

ORDER CODE

Auteldac 4 Curly Cord 18btn standard unit 18btn + headset socket* CB standard unit CB + headset socket*

212-02-2008-031 212-02-2008-231 212-02-2000-031 212-02-2000-231

Dust & Gas Gas Dust & Gas Gas

Auteldac 4 Stainless Steel Cord

18btn standard unit 18btn + headset socket* CB standard unit CB + headset socket*

212-02-2008-020 212-02-2008-220 212-02-2000-020 212-02-2000-220

Gas Gas Gas Gas

Headset & Plug for Auteldac 4 *Headset and plug 100-02-0598-001 Gas

Extension Cord for Headset 610-35-2036-001

CONNECTION OPTIONS

Page 60: Product Catalogue for Operation Spares

13.0 VoIP AUTELDAC 4

Page 61: Product Catalogue for Operation Spares

GAI-Tronics Telephony VoIP Auteldac 4

VoIP IECEx and ATEX Approved Hazardous Area Telephone

World’s First IEC/ATEX Zone 1 VoIP telephone

Ex II 2 GD & Ex II 2 G ATEX Certified for Gas and Dust, IEC Ex certified

Zone 1 & 2, Zone 21 & 22 Compliant GOST-R & INMETRO Approved for Gas Power over Ethernet VoIP SIP Protocol (RFC3261) Web Page configuration Real time alarm reporting via e-mail Full keypad with 3 programmable

memory buttons, or CB variant Operating Temperature -20°C to +50°C Adjustable Sounder Configurable relay output Robust and weather resistant (IP66 with

curly cord, IP54 with steel cord) Industry standard robust handset with

curly cord or armoured stainless steel Headset option

Compliant

The VoIP Auteldac 4 (A4) is the world’s first ATEX and IEC Zone 1 & Zone 21 approved telephone. Providing simple network connection without the need for analogue convertors, extending VoIP access to arduous industrial atmospheres and environmental extremes.

With only one voice and data infrastructure to install and maintain, VoIP telephony saves time, money and call costs.

Certified for safe operation in hazardous areas, the VoIP A4 body is made from carbon loaded glass filled polyester. The elimination of moving parts ensures a high level of reliability in industrial and hazardous environments and enables ingress protection up to IP66.

The VoIP A4 telephone has a configurable relay output fitted as standard, which may be used for ring strobe activation or local speaker mute. An inductive coupler is fitted to aid the hard of hearing. For hands-free telephone use, the Auteldac 4 has the option of an ATEX approved headset.

Options: The VoIP A4 is offered with a choice of armoured stainless steel or curly handset cords.

18 button Full Keypad Included in the 18 button version, are 3 direct dial buttons for fast one touch dialling of pre-stored numbers. Includes: M1- M3 Memory buttons, plus S ‘Silence’ and LR ‘Last number redial’ 0 button This can be used to initiate a 'hotline'. Autodial on handset lift also available.

Easy configuration: password protected intuitive web pages held within the telephone can be accessed using a browser such as Internet Explorer to view, monitor and change settings within the telephone. 24/7 Availability: telephones with memory buttons have an automatic call divert facility so that if a number or URI is not available then up to 20 alternatives can be dialled automatically. W

OR

LD’S

FIR

ST IE

C/A

TEX

ZON

E 1

VOIP

TEL

EPH

ON

E

Page 62: Product Catalogue for Operation Spares

GAI-Tronics® - United Kingdom - Tel: +44 (0)1283 500500 - Fax: +44 (0)1283 500400 - [email protected] - www.gai-tronics.co.uk GAI-Tronics® (Corporate) - USA - Tel: +1(610) 777 1374 - Toll Free: 800 492 1212 - Fax: +1(610) 796 5954 - www.gai-tronics.com GAI-Tronics® S.r.l - Italy - Tel: +39 02 48601 460 - Fax: +39 02 4585 625 - www.gai-tronics.co.uk GAI-Tronics® - Malaysia - Tel: +60 3 8945 4035 - Fax: +60 3 8945 4675 - www.gai-tronics.co.uk GAI-Tronics® Austdac - Australia - Tel: 011 61 28 851 5000 - Fax: 011 61 29 899 2490 - www.austdac.com.au An ISO 9001, ISO 14001, OHSAS 18001 Registered Company The policy of GAI-Tronics is one of continuous improvement; therefore the company reserves the right to change specifications without notice.

B193-3-0711B/CN336306-001

TECHNICAL SPECIFICATIONS (please refer to technical manual for full product details) Enclosure: (Wall mounted) Black carbon loaded glass-filled polyester Handset: Polycarbonate handset with conductive coating, with coiled cord or stainless steel spiral cord (extended cord lengths available). Keypad: Weathersealed tactile digital keypad Certified Operating Temperature: -20°C to +50°C (-4°F to +122°F) for GOST-R -40° C to +50° C (-40°F to +122°F) Relative Humidity: Up to 95% (non-condensing) Weather Ingress protection: IP66 Curled cord, IP54 Steel Cord Connection type: Spring loaded cage clamps Network: 100BaseT Power Supply: External 24V min, 53Vmax dc or IEEE Compliant Power-Over-Ethernet (PoE). NOTE: over the spare pairs only. Draws up to 7W. Call set-up Protocol: Session Initiation Protocol (SIP) (RFC 3261 compliant) Codes & Audio: G.711 A-Law G.711 μ-Law G.722 G.729 G.723.1 MP-MLQ G.723.1 ACELP Codec preference sequence, DTMF in band/out of band (RFC2883), Configurable comfort tones (nation specific) Security: Password protected Quality of Service: Priority of IP Packets according to TOS and DiffServ VLAN Priority according to IEEE8021.p/802.1q Reliability: MTBF 60,000 hours. Redundancy: Supports up to 4 SIP proxys Configuration: Via configuration file or on board password protected web page server. Static IP address or DHCP. Monitoring: Automatic fault reporting via email or Syslog messaging. Real-time over TCP/IP proprietary Syslog application. Update Server: Configuration and Firmware update via TFTP NAT: Network Address translation traversal via STUN server IP Address: Static IP provisioning or Dynamic Host Configuration Protocol (DHCP) ICMP: Internet Control Message Protocol for inbuilt ping test Memory Dialling: Numbers or URIs (with comfort tones) Configurable Call Lists: Max 20 entries which divert to next in list if the call fails External I/O: Single Relay contact pair rated for external beacon or sounder. Configurable activation e.g. on ringing cadence. Contact rating 5Amps @250Vac max. Call Records: Via call description reports

Time/Date: Simple Network time Protocol with time zone and daylight saving. Date format – European / US Ringing: Configurable via configuration file or web page. 90db @ 1 metre typical. Configurable volume

Time Out: Enforces a fixed call maximum time limit (variable) from lifting of the handset. User selectable.

Weight: approx. 3.5 kg (7.7lb) DIMENSIONS: H292 x W190 x D140 mm (H11.5 x W7.5 x D5.5 inch) Fixing: H270 x W145 mm (H10.6 x W5.7 inch)

M20 GLANDS AND CABLE ENTRY

ORDER CODE

VoIP Auteldac 4 Curly Cord

18btn standard unit CB standard unit

212-02-7008-031 212-02-7000-031

Dust & Gas Dust & Gas

VoIP Auteldac 4 Stainless Steel Cord

18btn standard unit CB standard unit

212-02-7008-020 212-02-7000-020

Gas Gas

For headset version order codes, contact GAI-Tronics

APPROVALS This mark indicates compliance with the following

directives; ATEX Product Directive 94/9/EC The GAI-Tronics Quality Management System has been approved by LRQA to ISO9001:2008 & ISO 14001:2004 Certificate No. 861888 and OHSAS 18001:2007 Certificate No. 4004472 Telephone compliance Baseefa09ATEX0261

II 2 GD (curly cord, no headset) Ex e ib mb IIC T4 Gb (-20°C to +50°C) Ex ibD tb IIIC T180°C

II 2 G (steel cord and/or headset versions) Ex e ib mb IIC T4 Gb (-20°C to +50°C) IECEx BAS 09.0126 :Ex e ib mb IIC T4 Gb (-20°C to 50°C) GOST-R Approval (Russia) РОСС GB.ГБ06.В00825 (-40°C to +50°C) INMETRO Approval (Brazil) CEPEL-EX-2017/11 BR-Ex e ib mb IIC T4 Gb (-20°C to +50°C) Headset compliance

II 2 G EEx ib IIC T4 (-20°C to +40°C) TUV03ATEX2124 GOST-R Approval РОСС GB.ГБ06.В00825 (-40°C to +40°C)

Page 63: Product Catalogue for Operation Spares

14.0 MEDC DB3

Page 64: Product Catalogue for Operation Spares

Sales Enq. UK: +44 (0)1623 444 445 Sales Enq. USA: +1 (713) 937- 9772 E-Mail: [email protected] Web: www.coopermedc.com

Features Zone 1, Zone 2 and non-Ex use.

Ex de IIC T4/T5.

ATEX approved, EEx II 2GD.

Optional Exe terminal chamber.

IECEx certified Gb, Db.

UL Listed for USA and Canada:

– Hazardous locations:

Class I, Div 2, Groups A-D.

Class II, Div 2, Groups F & G.

Class I, Zones 1 & 2, AExd IIC T5.

– Ordinary locations: Audible-Signal Device.

GOST ‘R’ & ‘K’ certified.

Chinese (CQST) certified.

Brazilian (Inmetro) certified.

IP66 and IP67.

SIL 1 Certified.

Designed in accordance with EN54-3.

*Certified temperature: –55°C to +70°C.

All GRP corrosion free flamepaths.

Up to 118dB(A) output.

Integral volume control.

27 tones, user selectable.

Tones comply with UKOOA/PFEER guidelines.

Two tones may be switched via the external voltage supply – now available in a.c. and d.c. versions.

Tones may be programmed to customer specification.

d.c. version accepts any voltage between12V d.c. and 48V d.c.

End of line resistor option.

Sounder/Beacon Combination Unit available.

*Depending on version.

IntroductionThis range of lightweight all GRP, flameproof sounders is intended for use inpotentially explosive gas and dust atmospheres and has been designedwith high ingress protection to cope with the harsh environmental conditionsfound offshore and onshore in the oil, gas and petrochemical industries.

The flamepaths, flare and the body, are manufactured completely from a UVstable glass reinforced polyester.

Stainless steel screws and sinter are incorporated thus ensuring a corrosionfree product. A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths.

An optional Exe terminal chamber is available.

An uncertified version is available for use in non-explosive atmospheres.

6DS094/U

Exd(e), Weatherproof

DB3 Range - SOUNDERS - Up to 118 dB(A)

Cooper MEDC Limited, Unit B, Sutton Parkway,Oddicroft Lane, Sutton in AshfieldNG17 5FB, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212Houston, TX 77086, USA

Page 65: Product Catalogue for Operation Spares

Exd Exde UL GOST R Exde Chinese Exd

DB3 & DB3P –20°C to +70°C –20°C to +70°C –55°C to +70°C –20°C to +40°C –20°C to +55°C

DB3L & DB3LP* –55°C to+70°C –50°C to +70°C n/a –55°C to +55°C n/a

* DB3L & DB3LP IECEx Min Temp - 40ºC

Ordering RequirementsThe following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available for immediate shipping - contact sales office for details.

CertificationModel

Voltage Code12V - 48V d.c. 048110V a.c. 110120V a.c. 120220V a.c. 220230V a.c. 230240V a.c. 240254V a.c. 254

Voltage

Finish CodeNatural Black NRed RSpecial S*

Finish

Option CodeNone NEnd of line E*resistorSpecial tone S

Options

Entries Code1 x M20 (Exd) 1B2 x M20 (Exd/Exde) 2B1 x 1/2" NPT (UL only) 1C2 x 1/2" NPT (UL only) 2C

Entries

Model DetailsDB3 Standard unitDB3P Two stageDB3L*† Low temp.

standard unitDB3LP*† Low temp.

two stage

* State value.

* Please specify.

* Available unpainted only.† Min IECEx temp - 40ºC.

* Not all options are available UL listed.

Ø170±2

2xM20 ENTRIES MAX(Exd UNIT)

36±1

FOR Exd UNIT, POSITION 2 IS USEDIF ONLY 1 x M20 ENTRY REQUIRED

30±1 CRS

30±1 CRS

22.5°(Exd)

22.5°(Exd)

60°(Exe)

1

3

2

193±2

FIXING HOLESØ9±1 (2 POS.)

322±3271±3 WITHOUT Exe CHAMBER

FIXING HOLEØ13±1

2xM20 ENTRIES(Exe UNIT)

OPTIONALExe CHAMBER

ALL DIMENSIONS IN MILLIMETRES

Ø117.5±2

Two Stage Unit DB3P: Switchable between two tones:D.C. (i) Reversing the polarity of the supply, or

(ii) by a 3 wire common +ve system, switching between thetwo –ve lines.

A.C. (iii) Closing/opening connection between 2 terminals e.g.by using a volt free relay contact at the panel. 2 tones must be specified at time of order.

3 & 4 Tone unit: Remote 3 & 4 tone unit available – contact sales office for details.

V I12V d.c. 760mA24V d.c. 380mA48V d.c. 190mA110V a.c 135mA120V a.c. 124mA

Current ConsumptionV I

220V a.c. 68mA230V a.c. 65mA240V a.c. 62mA254V a.c. 59mA

*Nominal Output dB(A) Input Current mA93 50105 100108 150111 200112 250114 300115 350

*Output measured with 24V input voltage. Tone set to 970Hz continuous.

Volume Control

To specify certifiedplug, suffix appropriatecode with 'P', e.g. 2BPis 2 x M20 entries withone certified plug.

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/13

Certified Temperature:

Label CodeDuty D*Tag T*None N

Labels

* Please specify wording.

SpecificationCertification: Certified to IEC60079-0, IEC60079-1, IEC60079-7, IEC60079-31.

Certified to EN50014, EN50018, EN50019.ATEX EEx d Cert. No. BAS00ATEX2097X.Ex II 2GD, EEx d IIC T4/T5.ATEX EEx de Cert. No. BAS00ATEX2098X.Ex II 2GD, EEx de IIC T4/T5.Zones 1 and 2.IECEx Exd Cert. No. IECEx BAS 11.0083X.Ex d IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db.IECEx Exe Cert. No. IECEx BAS 11.0084X.Ex de IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db.UL Listed for USA and Canada.– Hazardous locations:

Class I, Div 2, Groups A-D.Class II, Div 2, Groups F & G.Class I Zones 1 & 2, AExd IIC T5.

Listing No: E203310.– Ordinary locations: Audible-Signal Device.Listing No. S8116.Refer to UL data sheet at rear of catalogue for complete information.GOST ‘R’ Certification: 1Exd IIC T4 & 1Exde IIC T4.Russian Fire Approval.GOST ‘K’ Certification: Exd IIC T4 & Exde IIC T4.Chinese (CQST) Certification: Exd IIC T4.Brazilian (Inmetro) Certification: Ex d IIC T5/T4/Gb.Ex de IIC T5/T4/Gb.SIL 1 Certification. Cert. No. Sira FSP12003.Designed in accordance with EN54-3.

Material: Body & horn in anti-static, UV stable, glass reinforced polyester.Swivel bracket & captive cover screws in stainless steel.

Finish: Body and horn, natural black or painted to customer colour requirements.

Voltage: Up to 48V d.c. Up to 254V a.c.Weight: 6.0kg approx. dependent on model (+0.5kg for Exe).Ingress Protection: IP66 & 67.Entries: Up to 2 x M20 Exd 2 x M20 Exe.

Up to 2 x 1/2" NPT UL.Note: ATEX/UL Dual Listed version up to 2 x 1/2".NPT or 2 x M20 via adapter (fitted).

Terminals: 4 x 2.5mm2 (a.c.), 6 x 2.5mm2 (d.c.).Output: Long Flare: 115dB(A) ± 3dB(A) (tone dependent).

Short Flare: 108dB(A) ± 3dB(A) (tone dependent).Fire Retardancy: GRP is fire retardant to ISO 1210.Mounting: Stainless steel bracket with ratchet facility.Earth Continuity: Included on Exde version.Labels: Duty and tag labels optional.Tone Selection: 27 user selectable tones available.Sounder/Beacon Unit: The DB3 may be combined with an MEDC beacon to create a

combined audio/visual alarm.Contact MEDC for price and specification.

Certification CodeUncertified WExd DExde EIECEx Exd DJIECEx Exde EJUL Listed UL*UL (Ordinary Locations) UWATEX/UL Dual Listed AUGOST ‘R’ Exd DGGOST ‘R’ Exde EGGOST ‘K’ Exd DKGOST ‘K’ Exde EKChinese (CQST) QInmetro Exd DMInmetro Exde EM

ALL DIMENSIONS IN MILLIMETRES

Page 66: Product Catalogue for Operation Spares

15.0 AVAYA 1608

Page 67: Product Catalogue for Operation Spares

Avaya one-X Deskphone Value

Edition is a family of cost effective

IP Telephones that deliver familiar

features at an attractive price

point for the customer with basic

communications needs.

Designed with the reliability you expect

from Avaya, one-X Deskphone Value

Edition telephones provide critical

features and capabilities not often

found in competitively priced models.

Avaya one-X Deskphone Value Edition

combines traditional telephone

features such as LED lights and fixed

feature buttons (e.g. conference,

transfer, hold) with the latest in

user experience features such

as softkeys, a navigation wheel

and a context sensitive user

interface in select models.

It also offers as a standard:

2-way speakerphones, backlit

displays and multi-line capabilities.

Avaya one-X Deskphone Value Edition

models feature a stylish design and

are a sharp addition to any retail store,

branch, or corporate office.

The Avaya 1608 IP Telephone is

designed for the Everyday user.

Everyday users typically rely on several

forms of communication including

voice and email – and while they

require a quality telephone, they rarely

receive more that five or six calls per

day. Cubicle workers and sales staff

within a retail store are examples of

Everyday users for whom the 1608

delivers a productivity-enhancing

telephone.

The Avaya 1608 supports 8 line

appearances / feature keys. Each of

the buttons includes dual LED’s (red,

green) providing explicit status for the

user. For a familiar look and feel, the

1608 includes several fixed feature

keys for common telephone tasks

including conference, transfer, drop,

hold, mute. In addition, the 1608

includes a high quality full duplex

speakerphone, and supports a broad

portfolio of Avaya wired and wireless

headsets through its integrated

headset jack.

The 1608 features a context sensitive

user interface along with three softkeys

and a four-way navigation cluster

– ideal for scrolling through the local

contacts list or call logs. The display

on the 1608 measures three lines by

24 characters and is backlit for easier

viewing in all lighting conditions.

Avaya one-X® Deskphone Value Edition1608, 1608-I* IP Telephones

Avaya one-X is a portfolio of communications solutions that deliver

a powerful and consistent communications experience for the

end user – across a variety of devices and interfaces. Avaya one-X

solutions provide Intelligent Access to communications driving

enhanced productivity and competitive advantage.

PRODUCT BRIEF

avaya.com

Page 68: Product Catalogue for Operation Spares

And keep in mind:

Security and reliability: With enhanced

protection against denial of service attacks as

well as improved VLAN separation, the 1608

delivers the high level of security and quality

that you’ve come to expect from Avaya.

Key Features

Hardware:

• Backlit display – 3.5” diagonal,

3 rows by 24 characters

• Ergonomic hearing aid compatible

handset – supporting TTD acoustic

coupler

• 8 line appearance/feature key buttons

– with dual LED’s (red, green)

• 2-way speakerphone**

• Message waiting indicator

• Dual position flip stand

• Four-way navigation cluster button

• Three contextual softkey buttons

• Volume button – (separate volume levels in

the handset, headset, speaker, and ringer)

• Quick-access Voicemail Message button

• Telephony application button – to return

to main telephone screen

• Avaya Menu button – (options and

settings access)

• Contacts button

• Call log button

• Redial button

• Speaker button

• Mute button

• Headset button

• Hold button

• Conference button

• Transfer button

• Drop button

• Ethernet (10/100) line interface with

a secondary 10/100 port for collocated

laptop or PC

• PoE 802.3af class 2 device, also

supports a local power supply

• Headset interface

• Wall mount kit available

• Optional Gigabit Adapter for Gigabit

connectivity to a PC

Software:

• Contacts application – supports up to

100 entries

• Call log – contains last 100 calls

• H.323 protocol support

• Standards-based codec support: G.711,

G.726, G.729A/B

• Supports the following languages:

English, French, Spanish, German,

Italian, Dutch, Portuguese, Russian,

Japanese (half width Katakana).

• Additional language support available on

the 1608-I: Traditional Chinese, Simplified

Chinese, Korean, Hebrew and Arabic.

Requirements:

• Avaya Communication Manager 3.0

or greater

• Avaya IP Office 4.2 (11) or greater

• Local or centralized electrical power.

Through an 802.3af switch, or local

power supply.

• HTTP file server

Learn More

For more information about how Avaya

IP Telephone solutions may be leveraged to

help grow revenue and reduce costs, contact

your Avaya Client Executive, Avaya Authorized

BusinessPartner or visit avaya.com and click

on IP Telephony.

* 1608-I supported on Avaya Communication Manager (available in China, Taiwan, Korea, Israel and the Arabic speaking Middle East countries)

** Full Duplex speakerphone supported on Avaya Communication Manager

© 2011 Avaya Inc. All Rights Reserved. Avaya and the Avaya Logo are trademarks of Avaya Inc. and are registered in the United States and other countries. All trademarks identified by ®, ™, or SM are registered marks, trademarks, and service marks, respectively, of Avaya Inc. All other trademarks are the property of their respective owners. Avaya may also have trademark rights in other terms used herein. References to Avaya include the Nortel Enterprise business, which was acquired as of December 18, 2009.07/11 • LB3383-04

About Avaya

Avaya is a global provider of business collaboration and communications

solutions, providing unified communications, contact centers, data solutions

and related services to companies of all sizes around the world. For more

information please visit www.avaya.com.

avaya.com

Page 69: Product Catalogue for Operation Spares

16.0 AVAYA 1616

Page 70: Product Catalogue for Operation Spares

Avaya one-X Deskphone Value

Edition is a family of cost effective

IP Telephones that deliver familiar

features at an attractive price

point for the customer with basic

communications needs.

Designed with the reliability you

expect from Avaya, one-X Deskphone

Value Edition telephones provide

critical features and capabilities not

often found in competitively priced

models. Avaya one-X Deskphone

Value Edition combines traditional

telephone features such as LED

lights and fixed feature buttons (e.g.

conference, transfer, hold) with the

latest in user experience features

such as softkeys, a navigation

wheel and a context sensitive

user interface in select models.

It also offers as a standard:

2-way speakerphones, backlit

displays and multi-line capabilities.

Avaya one-X Deskphone Value Edition

models feature a stylish design and

are a sharp addition to any retail store,

branch, or corporate office.

The Avaya 1616 IP Telephone is

designed for the Navigator user.

Receptionists, assistants, and

managers are examples of Navigator

users – people who answer incoming

calls, transfer customers to different

departments or extensions, and

monitor several line appearances

throughout a typical day. For the

Navigator user, the 1616 provides the

most one-touch line/feature/speed-

dial buttons without the need to scroll

through on-screen lists.

The Avaya 1616 supports 16 line

appearances/feature keys on the phone

itself – and a 32 button expansion

model provides access to a total of

48 feature keys or speed dial buttons.

Each of the buttons features a dual

LED (red, green) providing explicit

status for the user. For a familiar

look and feel, the 1616 includes

several fixed feature keys for common

telephone tasks including conference,

transfer, drop, hold, and mute. In

addition, the 1616 includes a high

quality 2-way speakerphone, and

supports a broad portfolio of Avaya

wired and wireless headsets through

its integrated headset jack.

The 1616 features a context sensitive

user interface along with three

softkeys and a four-way navigation

cluster – ideal for scrolling through

the local contacts list or call logs.

The viewing angle of the display on

the 1616 is adjustable and measures

four lines by 24 characters. Additional

Avaya one-X® Deskphone Value Edition1616, 1616-I* IP Telephones

Avaya one-X is a portfolio of communications solutions that deliver

a powerful and consistent communications experience for the

end user – across a variety of devices and interfaces. Avaya one-X

solutions provide Intelligent Access to Intelligent Communications

driving enhanced productivity and competitive advantage.

produCt brIef

avaya.com

Page 71: Product Catalogue for Operation Spares

caller related information is displayed with

active appearances for easier call handling.

The display is backlit for easier viewing in

all lighting conditions.

And keep in mind:Security and reliability: With enhanced

protection against denial of service attacks as

well as improved VLAN separation, the 1616

delivers the high level of security and quality

that you’ve come to expect from Avaya.

Key FeaturesHardware:

• Backlit display – 3.5” diagonal, 4 rows by

24 characters with adjustable display angle

• Ergonomic hearing aid compatible handset

– supporting TTD acoustic coupler

• 16 line appearance/feature key buttons

– with dual LED’s (red, green)

• 2-way speakerphone**

• Message waiting indicator

• Dual position flip stand

• Four-way navigation cluster button

• Three contextual softkey buttons

• Volume button – (separate volume levels in

the handset, headset, speaker, and ringer)

• Message button

• Telephony application button – to return

to main telephone screen

• Avaya Menu button – (options and

settings access)

• Contacts button

• Call log button

• Redial button

• Speaker button

• Mute button

• Headset button

• Hold button

• Conference button

• Transfer button

• Drop button

• Ethernet (10/100) line interface with

a secondary 10/100 port for collocated

laptop or PC

• Module interface – for 32 button

expansion module

• PoE 802.3af class 2 device, also

supports a local power supply

• Headset interface

• Wall mount kit available

• Optional Gigabit Adapter for Gigabit

connectivity to a PC

Software:

• Contacts application – supports up

to 100 entries

• Call log – contains last 100 calls

• H.323 protocol support

• Standards-based codec support:

G.711, G.726, G.729A/B

• Supports the following languages:

English, French, Spanish, German,

Italian, Dutch, Portuguese, Russian,

Japanese (half width Katakana).

• Additional language support available on

the 1616-I: Traditional Chinese, Simplified

Chinese, Korean, Hebrew and Arabic.

Requirements:• Avaya Communication Manager 3.0

or greater

• Avaya IP Office 4.2 (11) or greater

• Local or centralized electrical power.

Through an 802.3af switch, or local

power supply.

• HTTP file server

Learn MoreFor more information about how Avaya

IP Telephone solutions may be leveraged to

help grow revenue and reduce costs, contact

your Avaya Client Executive, Avaya Authorized

BusinessPartner or visit avaya.com and click

on IP Telephony.

* 1616-I supported on Avaya Communication Manager (available in China, Taiwan, Korea, Israel and the Arabic speaking Middle East countries)

** Full Duplex speakerphone supported on Avaya Communication Manager

© 2009 Avaya Inc. All Rights Reserved. Avaya and the Avaya Logo are trademarks of Avaya Inc. and may be registered in certain jurisdictions. All trademarks identified by ®, TM or SM are registered marks, trademarks, and service marks, respectively, of Avaya Inc All other trademarks are the property of their respective owners.01/09 • LB3384-04

About Avaya

Avaya is a global leader in enterprise communications systems. The company

provides unified communications, contact centers, and related services directly

and through its channel partners to leading businesses and organizations

around the world. Enterprises of all sizes depend on Avaya for state-of-the-art

communications that improve efficiency, collaboration, customer service and

competitiveness. For more information please visit www.avaya.com.

avaya.com

Page 72: Product Catalogue for Operation Spares

17.0 MMC VG504xM

Page 73: Product Catalogue for Operation Spares

www.multimedia-connect.com

This document is confidential, and is the property of TKH Group. TKH Group owns the copyright, and thedocument must not be copied or changed in any form, wholly or in part without written permission from TKHGroup. The contents of this document must be disclosed to any other person or persons.The characteristics related to this document are not contractual, and can be modified without warning.

PRODUCT INFORMATIONS

REF : VG504xMUTP 4 pairs RJ45 Patch cord Category 6 – 10G

Ed. 1.0 02/10

Page 74: Product Catalogue for Operation Spares

www.multimedia-connect.com

This document is confidential, and is the property of TKH Group. TKH Group owns the copyright, and thedocument must not be copied or changed in any form, wholly or in part without written permission from TKHGroup. The contents of this document must be disclosed to any other person or persons.The characteristics related to this document are not contractual, and can be modified without warning.

REF : VG504xMUTP 4 pairs RJ45 Patch cord Category 6 – 10G

Ed. 1.0 02/10

General characteristics

• Patch cord with moulded boots U/UTP – 4 pairs – Category 6 10G – 500 MHz• Each patch cord is delivery in individual polybag.• The patch cords are available in 5 colours ( Grey – Blue – Yellow – Red – Green ), and 5 lengths ( 1m – 2m – 3m –

5m – 10m )• Colour code : TIA/EIA 568 B• Plug : UTP : RJ45 8P 8C for round cable – contact : 15 µinch gold.• The conductors are shifted on 2 levels to ensure a better cross talk (NEXT).

Standards / Performances

Performances of cable comply with the limits defined by the following standards:

Characteristics Colour code

Code EIA/TIA 568 B

1 WHITE/ORANGE2 ORANGE3 WHITE/GREEN4 BLUE5 WHITE/BLUE6 GREEN7 WHITE/BROWN8 BROWN

COMPONENT SYSTEMEIA/TIA 568-B.2-1 Category 6 EIA/TIA TSB155 10G over Category 6

ISO TR24750 10G over CLASS E

Fire beahaviour : IEC 60332-1 / NF C 32070 C2

Temperature range : - 20° C / + 70°C

Minimum bending radius: 8 x cable diameter

Conformity with RoHS directive

Page 75: Product Catalogue for Operation Spares

www.multimedia-connect.com

This document is confidential, and is the property of TKH Group. TKH Group owns the copyright, and thedocument must not be copied or changed in any form, wholly or in part without written permission from TKHGroup. The contents of this document must be disclosed to any other person or persons.The characteristics related to this document are not contractual, and can be modified without warning.

REF : VG504xMUTP 4 pairs RJ45 Patch cord Category 6 – 10G

Ed. 1.0 02/10

Values

FREQUENCY(MHz)

NEXT(dB/100 m)

RETURN LOSS(dB/100 m)

1 m 2 m 5 m 10 m 1 m 2 m 5 m 10 m1 65.0 65.0 65.0 65.0 19.80 19.80 19.80 19.80

4 65.0 65.0 65.0 65.0 21.61 21.61 21.61 21.61

10 65.0 65.0 64.5 62.9 22.80 22.80 22.80 22.80

16 62.6 62.0 60.5 59.0 23.41 23.41 23.41 23.41

20 60.7 60.1 58.6 57.2 23.70 23.70 23.70 23.70

31.25 56.9 56.2 54.9 53.6 23.05 23.05 23.05 23.05

62.5 51.0 50.4 49.2 48.1 20.04 20.04 20.04 20.04

100 47.0 46.4 45.3 44.4 18.00 18.00 18.00 18.00

250 39.2 38.8 38.1 37.6 14.00 14.00 14.00 14.00

500 25.2 25.1 25.1 25.0 9.00 9.00 9.00 9.00The installation & environmental requirements can modify the values above.Multimedia Connect reserves the right to modify the present characteristics without preliminary notification

Ordering informations

Designation Length

VG 504 x M Grey x = 1 / 2 / 3 / 5 / 10 m individualx : lengths of patch cords : 1 m - 2 m – 3 m – 5 m – 10 m

Page 76: Product Catalogue for Operation Spares

18.0 SG12-06B2A Grounding kit

Page 77: Product Catalogue for Operation Spares

SG12SG12--06B2A06B2A SureGround® Grounding Kit for 1/2 in coaxial cable

Dimensions Nominal Size 1/2 in Bonding Conductor Length 609.6 mm | 24 in Cable Jacketing Removal Length, maximum 38.1 mm | 1 1/2 in Cable Jacketing Removal Length, minimum 38.1 mm | 1 1/2 in Compatible Diameter, maximum 16.510 mm | 0.650 in Compatible Diameter, minimum 15.494 mm | 0.610 in

Electrical Specifications Current Handling Tested to withstand 100,000 amps peak current surge Current Handling Test Method MIL­STD­1757 Grounding, Bonding and Shielding Test Method MIL­STD­188­124A Lightning Protection Test Method IEC 1024­1

General Specifications Cable Type Corrugated | Smoothwall Grounding Kit Type SureGround™ Grounding Kits Brand SureGround™ Color Black Bonding Conductor Material Copper Bonding Conductor Wire Size 6 gauge Bonding Conductor Jacketing Material PE Grounding Strap Material Tinned copper Includes Grounding kit | Hardware | Lug | One roll of 2 in PVC tape | One

roll of 24 in butyl rubber tape Locking Bail Material Stainless steel Lug Attachment Factory attached Lug Type Two­hole lug Package Quantity 1 Rivet Material Tinned copper Weatherproofing Method Butyl and electric tape

Mechanical Specifications Blowing Rain Test Method MIL­STD­810, Method 506 Corrosion Test Method MIL­STD­1344, Method 1001 Freezing Rain/Icing Test Method MIL­STD­810, Method 521 Humidity Test Method MIL­STD­1344, Method 1002 Immersion Test Method IEC 60529:2001, IP68

Product SpecificationsProduct Specifications

©©2013 CommScope, Inc. All rights reserved. All trademarks identified by 2013 CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: August 6, 2013All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: August 6, 2013

page 1 of 2page 1 of 2October 22, 2013October 22, 2013

Page 78: Product Catalogue for Operation Spares

Operating Temperature ­40 °C to +85 °C (­40 °F to +185 °F) Storage Temperature ­40 °C to +80 °C (­40 °F to +176 °F) Thread Size 3/8 in UV Resistance Test Method MIL­STD­810, Method 505 Vibration Test Method MIL­STD­202, Method 214

Packed Dimensions Height 447.0 mm | 17.6 in Length 177.8 mm | 7.0 in Shipping Weight 0.59 kg | 1.30 lb Width 395.2 mm | 15.6 in

Regulatory Compliance/CertificationsAgency ClassificationISO 9001:2008 Designed, manufactured and/or distributed under this quality management system

Included Products

9905­71 — Black 2 in PVC Tape, 20 ft

42615­10 — Butyl Rubber Tape, 24 in

* Footnotes

Grounding, Bonding and Shielding Test Method Military Standard for Grounding, Bonding, and Shielding: Bond Resistance Requirement of a Maximum dc resistance of 0.001 ohm

Lightning Protection Test Method Protection Against Lightning Electromagnetic Impulse, Table 1—Protection Level III–IV, 1995­02

Product SpecificationsProduct SpecificationsSG12SG12--06B2A06B2A

©©2013 CommScope, Inc. All rights reserved. All trademarks identified by 2013 CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: August 6, 2013All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: August 6, 2013

page 2 of 2page 2 of 2October 22, 2013October 22, 2013

Page 79: Product Catalogue for Operation Spares

19.0 Tetra BHR21 IS

Page 80: Product Catalogue for Operation Spares

*Edition 03/2008 Note: The right to make technical changes without notice is reserved. The performance is dependent on the given infrastructure.

ATEX-TETRA Hand-held Radio BHR 21 ISFor working in hazardous areas according to II 2 G EEx ib IIC T4 & II 3 D T130°C IP54

FOR operation in explosive-prone areas radios must meet specific safety requirements.The BHR 21 IS is certified for use in areas where explosive materials (gases, dust) are to be expected such as the oil and gas industry, refineries and refuelling stations, gasworks and the petrochemical industry.Apart from a very high degree of safety the BHR 21 IS also offers exceptional performance.This radio has been designed for professional radio networks and complies with the TETRA Standard. The user is offered the full extent of the TETRA features.

PMRS GmbH

Tränkeweg 5

D-15517 Fürstenwalde

BRANCH OFFICE

Köpenicker Straße 325

House 201

D-12555 Berlin

T +49 (0)30 2000 362 0F +49 (0)30 2000 362 27

[email protected]

Internetwww.pmrs-gmbh.com

60 mm

145 mm

Audio-interface

General

dimensions (H x W x D):! 145 x 60 x 33 mmweight:! ! ! approximately 325 g incl. battery packbattery-capacity:! ! 3.000 mAh Li-Ion 3,7 V Akku (rechargeable)

operating time: up to 14 hrs (5% TX / 35% RX / 60% idle)

special feature:! ! changing battery in endangered environment is possible! ! ! ATEX grade: EExib IICT4, robust impact resistant housing

Handling

display:" " " 1,8“ RGB Colour-Display, 120x160 Pixel, 4096 Colourskeypad:! ! ! lighted, 12 alphanumeric and 6 function keys, 4 sidewise function

! ! keys (1x free choice programmable), 2 rotary-switches (group ! ! select and volume select), emergency button on top side

circuit points:! ! audio-interface on top side, I/O-Connector for data transmission ! ! and battery recharge, recharging female on bottom side, additionally antenna female ! ! for car equipment

illuminated ring:! ! LED on top side with different colours for different statusdisplay languages:! ! German, English, French, Spanish, Dutch, Russian, Greekgroups TMO/DMO:! ! preprogrammed groups and multigroups phonebook:! ! preassigned telephone numbers and namesstatus calls/text:! ! alphanumeric generation of short data telegrams via key-pad ! ! ! (predefined or manual status)! ! !

Environmental conditions

operating temperature: " From -20°C to +55°Cstorage/ transport temperature:" From -20°C to +60°C

protection class: IP 54

Radio applications

wave band: 360 – 380 / 380 – 400 MHz; 380 – 400 / 406 – 430 MHz; 406 – 430 / 450 – 470 MHz

operating mode:! ! trunked mode (TMO), direkt mode (DMO) transmitting power:! ! 1 Watt (class 4), automatic transmission power controlreceiving class:! ! A (standard: TU 50, HT 200)speech mode:! ! simplex (trunking mode), duplex (phone mode)

Upgrading/ Extention

position and movement sensorTETRA Air Encryption Class 1/ Class 2Dead-Man-Switch (position related) optional

Furthermore please notice our large offer.

Pe

rfo

rma

nc

e f

ea

ture

s a

nd

te

ch

nic

al d

eta

ils

Produced in

Germany

! Quality Management System Zertifi ziert nach ISO 9001 : 2000 ZELM 06 ATEX 1292

Page 81: Product Catalogue for Operation Spares

20.0 Etelm Tetra Amplifier

Page 82: Product Catalogue for Operation Spares

POWER AMPLIFIER TETRA BANDS

CIV

IL AN

D M

ILITAR

Y C

OM

MU

NIC

ATIO

NS

C/Santa Leonor, 61 28037 Madrid

www.infacom.es [email protected]

Specification subject to change without notice

‐Innovation ‐Quality ‐Reliability

81

184

20

20

30

Ø3,2

9047

2,2

5

Features

◊ Cover all TETRA bands. ◊ High output power. ◊ High linearity. ◊ Excellent IP3 figure. ◊ High gain. ◊ Robust and reliable. ◊ Operating temperature -40/+75 ºC. ◊ Optional IP68.

Dimensions in mm

Specifications

Parámetros Valores Unidades

Operating frequency 380‐450 MHz

Max input power no damage ‐19 dBm

Small signal gain 65 dB

Output power at 1 db compression 45 W

Saturation power 50 W

Gain flatness +/‐1 dB

Harmonics ‐45 dbc

Spurious ‐80 dbc

IP3 +57 dBm

Impedance 50 Ω

Return loss at input/output. 12 dB typ

Conectorization. N (f)

Power supply. +24 / 5 VDC / A

Hermeticity level IP 66

Baseplate temperature. ‐40 /+75 ºC

Storage temperatura. ‐45 / +85 ºC

Size. 130x 80 x 30 mm

Weight. 0.4 Kg

74

Description.

The model IF-AMP-110 / N has been designed for intensive use in civil TETRA bands either emergency or everyday use. It can provide 50W output power with a gain of 65 db. The technology used allows to achieve high performance and high linearity value throughout the operating band, so that is recommended for all applications whether analog and/or digital. The IP66 hermeticity level allows use both indoors and outdoors applications. The output port is protected by an isolator, so that allows to work in extreme conditions, as short circuit and open circuit. The amplifier requires a suitable heat sink for proper operation. Custom solutions in power, gain, hermeticity and size.

Page 83: Product Catalogue for Operation Spares

21.0 Pelco KBD5000

Page 84: Product Catalogue for Operation Spares

PRODUCT SPECIFICATION

video management solutions

KBD5000 KeyboardFULL FUNCTIONALITY, MODULAR CONTROLS, PAN/TILT/ZOOM CONTROL

Product Features • Controls Located on 3 Modules in the Keyboard

• Modules Can Be Rotated to Suit User Preference

• 1 Keyboard Can Control All System Cameras Through a VCD5202 Interface

• Built-in USB Hub for Connection of Export Devices

• Variable Speed, Vector-Solving Joystick for Precise Pan/Tilt/Zoom (PTZ) Control

• Jog/Shuttle for Playback Control and Menu Navigation

• Keypad Call-Up of Cameras, Presets, and Patterns

• Built-in Speaker

The KBD5000 keyboard is optimized for surveillance requirements incontrolling virtual matrix cameras. User feedback is provided throughthe VCD5202’s head-up display and built-in LED lighting on thekeyboard. It is compatible with the Endura®-distributed IP videosurveillance system and Endura-based DVRs. Limited functionality isavailable for the DS ControlPoint user interface and the EnduraWS5200 client interface.

The KBD5000 is configured with three control modules that can berotated individually to provide ergonomic comfort for the operator.These modules include:

• A variable speed, vector-solving joystick with keys for lens iris andfocus control. The barrel-type joystick provides precise pan and tiltcontrol of fixed speed and variable speed positioning systems.Twisting the joystick zooms the lens in and out. The joystick andcontrol buttons are used for navigating the on-screen configurationmenus of the compatible VCD5202.

• A jog dial/shuttle ring for playback and menu navigation. Thejog/shuttle contains four illuminated function keys. Each key’s colorcorresponds to the color of the icons displayed on the monitorslinked to the user interface. This intuitive color matching design letsusers navigate the on-screen menus without taking their eyes off ofthe video to read keyboard text labels.

• A keypad for camera and monitor control. Keys select cameras andmonitors and the number of cameras to view.

The KBD5000 contains a built-in wrist support for added comfort.The context-sensitive Help key is another unique feature of thiskeyboard. In addition, easy export is accomplished using theKBD5000’s USB port.

The KBD5000 can be logically configured so any number ofkeyboards can be added to the system. When combined with Pelco’sEndura IP video management system, the KBD5000 deliversCCTV-style control for virtual matrix applications.

C1620 / REVISED 10-14-10

International StandardsOrganization Registered Firm;

ISO 9001 Quality System

Page 85: Product Catalogue for Operation Spares

TECHNICAL SPECIFICATIONS

Pelco, Inc. Worldwide Headquarters:3500 Pelco Way, Clovis, California 93612-5699 USAUSA & Canada Tel: (800) 289-9100 • FAX: (800) 289-9150International Tel: +1 (559) 292-1981 • FAX: +1 (559) 348-1120www.pelco.com

MODELKBD5000 Desktop keyboard with control pods for full

switching and configuration capabilities, plus joystick control of PTZ functions and jog/shuttle playback control

SUPPLIED ACCESSORIES1 external power supply3 power cords (1 USA standard, 1 UK standard, and 1 European standard)

POWER SUPPLYInput Voltage 100 to 240 VAC, 50/60 HzOutput Voltage 12 VDCPower Output 20 WInput Connector Type UniversalOutput Connector Type 2.5 mm screw-on barrel

KEYBOARD BASEKeyboard Interface USB 2.0Cable USB, captive, 16.4 ft (5.0 m)Input Voltage 12 VDCInput Current 1.3 A (maximum)Upstream Port USB 2.0 (USB type B connector)Downstream Port 2, USB 2.0 high/full/low speed (USB type A

connector)Audio Output Embedded speaker or plug-in headset, 0.5 W

into 8-ohm load per channelAudio Input* Plug-in microphone, mono, (30 to 350 mVp-p);

or line input, stereo (0.35 to 2.0 Vp-p)

*Reserved for future use.

KEYBOARD MODULESKeyboard Keypad 0 to 9 keys, camera, monitor, and multiple

view keysJoystick Fully proportional pan/tilt, variable speed;

with zoom, iris, and focus controlsJog/Shuttle Proportional, fast forward, reverse, and video

transport; menu navigation on VCD5202 video console display

GENERALDimensions

Without Wrist Support 7.86" D x 14.78" W x 4.6" H (19.96 x 37.54 x 11.68 cm)

With Wrist Support 9.94" D x 16.88" W x 4.6" H (25.25 x 42.88 x 11.68 cm)

WeightsUnit Weight

Without Wrist Support 2.68 lb (1.22 kg)With Wrist Support 3.32 lb (1.51 kg)

Shipping Weight 5 lb (2 kg)

ENVIRONMENTALOperating Temperature 32° to 104°F (0° to 40°C) at unit air intakeStorage Temperature –40° to 149°F (–40° to 65°C)Operating Humidity Up to 96%

CERTIFICATIONS/RATINGS/PATENTS• CE, Class B• FCC, Class B• UL/cUL Listed• C-Tick• S Mark for Argentina• U.S. Patents #D525,262 S; D515,580 S; D516,073 S

IMPORTANT NOTE: PLEASE READ. The network implementation is shown as generalrepresentation only and is not intended to show a detailed network topology. Your actual network willdiffer, requiring changes or perhaps additional network equipment to accommodate the system asillustrated. Please contact your local Pelco Representative to discuss your specific requirements.

KBD5000 KEYBOARD

VIDEOCONSOLEDISPLAY

Pelco, the Pelco logo, and other trademarks associated with Pelco products referredto in this publication are trademarks of Pelco, Inc. or its affiliates. All other

product names and services are the property of their respective companies.Product specifications and availability are subject to change without notice.

©Copyright 2010, Pelco, Inc. All rights reserved.

Page 86: Product Catalogue for Operation Spares

22.0 Pelco IPSXM30

Page 87: Product Catalogue for Operation Spares

PRODUCT SPECIFICATION

camera solutions

ExSite® Series Explosionproof Positioning SystemPAN/TILT SYSTEM WITH IOP CAMERA AND OPTIONAL WIPER

Product Features • Electropolished 316L Stainless Steel Construction

• Upright or Inverted Operation

• Receiver, Pan/ Tilt, and Enclosure with an Integrated Optics Package (IOP)

• 2 Autofocus, High Resolution Integrated Optic Packages

– 23X Day/Night, 80X Wide Dynamic Range, Motion Detection, and 540 TVL Horizontal Resolution

– Color 22X EXview HAD™

• Multilingual On-Screen Menus

• Password Protection

• Programmable Camera Settings

• On-Screen Compass, Tilt, and Zoom Display

• Variable Speed Pan: 0.1° to 40°/second with Proportional Pan

• 360° Continuous Pan Rotation

• Tilt Range of +90° to -90° from Horizontal

• Preset Positioning, Patterns, Multiple Scan Modes

• Designed for Minimal Maintenance

• Built-in System Memory

• Software Update and Setup Through Remote Data Port (IPS-RDPE-2)• Password Protection to Prevent Unauthorized Changes to the System

• On-Board Connector for– Pelco VC-UTP Video Converter– Pelco TXB Series Translator Boards for Use with Hernis and Other

Protocols– Pelco FS85011A and Third-Party Fiber Optic Transmitters

The ExSite® Series are innovative integrated positioning systems thatmeet stringent explosionproof requirements. The ExSite Series notonly combine a receiver, pan/tilt, and enclosure in a single, easy-to-install system, but also includes an Integrated Optics Package (IOP). TheIntegrated Optics Package contains an autofocus camera and lensmodule with programmable features.

For a wide range of applications, the ExSite Series feature a choice oftwo different IOP cameras: a high resolution camera with LowLight™

color technology and 22X zoom lens (22X optical, 12X digital), and a highresolution day/night camera with a removable infrared cut filter and23X zoom lens (23X optical, 12X digital).

The electropolished 316L stainless steel construction makes theExSite Series ideal for all kinds of environmental conditions includingmarine applications. The system has an absolute operatingtemperature range of -76° to 140°F (-60° to 60°C). Within two hoursafter power-up, the entire unit can de-ice and be operational from atemperature of -13°F (-25°C).

The ExSite Series include an optional window wiper. The wiper iscompletely integrated into the enclosure and does not interfere with theviewing range of the system. The wiper can be programmed to delay

between wipes and to automatically shut off after a specified period.A built-in heater, window defroster/defogger, sun shroud, and blowerare standard features on the ExSite Series. All units also include threeauxiliary output relays that can be programmed for a variety of uses.

The ExSite Series variable pan and tilt speeds range from0.1 to 40 degrees per second in manual pan, tilt, and preset mode.The ExSite Series is capable of 360 degrees of continuous panrotation. The t i l t range al lows for horizontal v iewing of-90 to +90 degrees. There are 80 preset positions with a presetaccuracy of ±0.1 degree.

The systems are available with an input voltage of 24 VAC or with apower source of 100 to 240 VAC. The ExSite Series also have a power-up recovery mode that allows the user to specify what operation thesystem will resume whenever the power is cycled.

ExSite Series feature built-in system memory in the power module tostore camera and location-specific pan/tilt settings, including labels,presets, patterns, and zones. These settings are automatically down-loaded if a new pan and tilt body is installed.

SHOWN WITH WXM100 WALL MOUNT(NOT SUPPLIED)

C1300 / REVISED 8-19-09

International StandardsOrganization Registered Firm;

ISO 9001 Quality System

Page 88: Product Catalogue for Operation Spares

TECHNICAL SPECIFICATIONS

PRODUCT FEATURES• Integral Multiprotocol Receiver/Driver• 360° Continuous Pan Rotation, Tilt Range ±90°• Quick and Easy Installation• Designed for Minimal Maintenance, No Gears to Adjust• 2-Year Continuous-Duty Warranty• Upright or Inverted Installation

SOFTWARE/HARDWARE• Programmable Power-up Mode• Programmable Park• Sun Shroud, Heater/Window Defroster, and Blower All Standard• 80 Presets with Custom Camera Settings and Labels• ±0.1° Preset Accuracy• Multilingual Menus (English, Spanish, Portuguese, Italian, French,

German, Russian, Polish, Turkish, and Czech)• On-Screen Compass, Tilt, and Zoom Display• Password Protection• 8 Zones (programmable in size) Can Be Labeled with Up to 20 Characters

Each or Set to Output Blank Video• Programmable Locations of Labels and On-Screen Displays• 7 Alarm Inputs• 3 Relay Outputs• Action on Alarm: Alarms can be individually programmed for 3 priority

levels, to initiate a stored pattern, or to go to an associated preset when received

• Resume After Alarm: Allows the pan/tilt to return to a previously programmed state after alarm acknowledgement or to its previous position before alarm

• Patterns: Up to 4, on-screen, user-defined programmable patterns. Includes pan, tilt, zoom, and preset functions

• Proportional Pan/Tilt: Continually decreases pan and tilt speeds in proportion to depth of zoom

• Variable Scan Speed: Scan speed can be programmable between 1° and 40°/sec

• Programmable Limit Stops for Auto/Random/Frame Scan Modes• Autosensing Protocol (Coaxitron®, RS-422 P and D); Accepts Competitive

Control Protocol with Optional Translator Card• Built-in Menu System for Setup of Programmable Functions

ALL CAMERAS• Autofocus with Manual Override• Auto Iris with Manual Override• Programmable Settings• AC Line Lock• NTSC/PAL

ELECTRICALInput Voltage 24 VAC or 100 to 240 VAC, 50/60 HzInput Voltage Range ±10%Power Consumption Maximum 60 W (120 VA) per systemHeater and Defroster Microprocessor controlled Electrical Connections 6-foot pigtail wire harness with connections

for power, video, data control, alarm inputs, and auxiliary outputs

Auxiliary Outputs 3 N/O or N/C relays, 32 VDC, 0.5 A. Relay 3 is allocated specifically for an external washer (not supplied by Pelco).

Alarm Inputs 7

MECHANICALCable Entry One 0.75-inch (1.91 cm) NPT threaded

opening; one explosionproof sealable fitting supplied

Pan Movement 360° Continuous pan rotationVertical Tilt Unobstructed +90° to -90°Variable Pan/Tilt Speed

Pan 0.1° to 40°/sec variable-speed operationTilt 0.1° to 40°/sec variable-speed operation

Preset SpeedsPan 40°/secTilt 40°/sec

5.54(14.07)

16.54(42.01)

11.5 (29.21)

7.12(18.08)

4.91(12.47)

5.13(13.03)

13.14 (33.37)

0.75 NPT(1.91)

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;ALL OTHERS ARE INCHES.

4 PLCS. TYP.10MM - 1.5MM X 14MMON A 4.75-INCH DIA. B.C.EQUALLY SPACED

3.354(8.52)

Page 89: Product Catalogue for Operation Spares

TECHNICAL SPECIFICATIONS

GENERALConstruction 316L stainless steelFinish ElectropolishViewing Window 0.50-inch (12.7 mm) thick, soda-lime

tempered glassOperating Temperature -76° to 140°F (-60° to 60°C)Unit Weight 55 lb (25 kg)Shipping Weight 73 lb (33 kg) Effective Projected Area (EPA) 40.8 square inches

CERTIFICATIONS/RATINGS• UL/cUL Listed • UL/cUL Hazardous Locations Listed per NEC Division and Zone

requirementClass I, Groups A, B, C, and DClass II, Groups E, F, G, T5Class I, Zone 1, AEx d IIC, Ex d IIC, T5

• 04/UL-BRAE-0027BR-Ex d IIC, T5, IP66

• IECEx UL 04.0010XEx d IIC, T5

• DEMKO 04 ATEX 0413858 0539 II 2 G Ex d IIC, T5 II 2 D Ex tD A21 IP66 T105°C

• Tamb -60°C to 60°C• NEPSI-China, Ex d IIC, T5, Cert No. GYJ05584• C-Tick• S Mark for Argentina• Meets NEMA Type 4X standards• Lloyd’s Register Type Approval: Marine, offshore, and industrial

installations for use in environmental categories ENV1, ENV2, and ENV5; Certificate No. 06/60001

CAMERA/OPTICSDay/Night (23X) Color, LowLight™ (22X)

Signal Format NTSC, PAL NTSC, PAL

Scanning System 2:1 Interlace 2:1 Interlace

Image SensorEffective pixelsNTSCPAL

1/4-inch Progressive Scan CCD

768 (H) x 494 (V)752 (H) x 582 (V)

1/4-inch EXview HAD™ CCD

768 (H) x 494 (V)752 (H) x 582 (V)

Horizontal ResolutionNTSCPAL

540 TV lines540 TV lines

>470 TV lines>460 TV lines

Lens f/1.6 (focal length, 3.6~82.8 mm optical) f/1.6 (focal length, 4~88 mm optical)

Zoom 23X optical, 12X digital 22X optical, 12X digital

Programmable Zoom Speed (Optical Range)

2.9/4.2/5.8 seconds 2.4/3.9/6.3 seconds

HorizontalAngle of View

Focus

54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoomAutomatic with manual override

47° at 4.0 mm wide zoom; 2.2° at 88 mm telephoto zoomAutomatic with manual override

Maximum Sensitivity at 35 IRE

NTSC 0.025 lux at 1/2 sec shutter (color)0.1 lux at 1/60 sec shutter (B-W)0.004 lux at 1/2 sec shutter (B-W)

0.02 lux at 1/2 sec shutter

PAL 0.025 lux at 1/1.5 sec shutter (color)0.1 lux at 1/50 sec shutter (B-W)0.004 lux at 1/1.5 sec shutter (B-W)

0.02 lux at 1/1.5 sec shutter

Sync System Internal/AC line lock, phase adjustable using remote control, V-Sync*

Internal/AC line lock, phase adjustable using remote control, V-Sync*

White Balance Automatic with manual override* Automatic with manual override*

Shutter SpeedNTSCPAL

Automatic (electronic iris)/Manual1/2~1/30,000*1/1.5~1/30,000*

Automatic (electronic iris)/Manual1/2~1/30,000*1/1.5~1/30,000*

Iris Control Automatic Iris Control with manual override* Automatic Iris Control with manual override*

Gain Control Automatic/OFF* Automatic/OFF*

Video Output 1 Vp-p, 75 ohms 1 Vp-p, 75 ohms

Video Signal to Noise >50 dB >50 dB

*Manual control of camera setup functions can be done with CM6700, CM6800, CM9760, CM9770, CM9780, KBD200A, KBD300A, and MPT9500 controllers. Manual control of cameras cannot be done with CM7500, MPT9000, or KBD9000 controllers.

Page 90: Product Catalogue for Operation Spares

MOUNTING ACCESSORIES

MODELSWXM100 Wall mount designed to mount the

ExSite Series system directly to a load-bearing vertical surface

PXM100 Pedestal mount designed to mount an ExSite Series system directly to a horizontal surface in either an upright or inverted position

CMXM100 Corner adapter for use with the WXM100 to mount an ExSite Series system to the corner of a structure

PAXM100 Pole adapter for use with the WXM100 to mount a system to a vertical pole or with a PXM100 to mount a system to a horizontal pole; recommended pole diameter is 4 to 9 inches (10.16 to 22.86 cm)

GENERALConstruction

Mounts Electropolished 304 stainless steelPAXM100 Mounting Straps 316 stainless steel

Maximum LoadWXM100 73 lb (33 kg)CMXM100 85 lb (38.50 kg)PAXM100 88 lb (40 kg)PXM100 79 lb (35.83 kg)

Unit WeightWXM100 12.4 lb (5.62 kg)CMXM100 7.6 lb (3.45 kg)PAXM100 9.2 lb (4.17 kg)PXM100 1.3 lb (0.60 kg)

Shipping Weight (approximate)WXM100 17 lb (7.71 kg)CMXM100 13 lb (5.89 kg)PAXM100 14 lb (6.35 kg)PXM100 4 lb (1.81 kg)

MECHANICAL

* Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with lock washers are supplied with the CMXM100 and PAXM100 to be used with the WXM100 wall mount or PXM100 pedestal mount.

Mounting Method RecommendedMounting Surface Recommended Hardware

WXM100, CMXM100*, and PXM100

Solid concrete with therecommended strength of 3,600 psi or 25 Mpa

Five 3/8-16 x 1-9/16-inch long stainless steel drop-in anchors and five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers (not supplied)

Steel I beam with a minimum of 1/8-inch wall

Five 3/8-16 x 1.0-inch thread length, stainless steel hex head bolts with stainless steel lock washers and 3/8-16 stainless steel nuts (not supplied)

PAXM100* Steel pole with a diameter of 4 to 9 inches (10.16 to 22.86 cm)

Four 5/8-inch wide x 40-inch (101.6 cm) long stainless steel straps to attach the adapter to a pole (supplied)

5X Ø 0.422

7.00(17.78)

3.50(8.89)

8.00(20.32)

14.95(37.97)

8X 0.433 THRU EQ SPON A 4.75 B.C.

Ø

5.74(14.58)

WXM100 WALL MOUNT

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.

Page 91: Product Catalogue for Operation Spares

MOUNTING ACCESSORIES

87)

14.9(37.8)

8.15(20.7)

5.5(14.1)

5X THREADED HOLESFOR 3/8-16 SS BOLTS (SUPPLIED)

9.25(23.5)

10.00(25.4)

3.28(8.33)

11 X THREADED HOLESFOR 3/8-16 SS BOLTS (SUPPLIED)

3.5(8.9)

8.50(21.6)

4X 0.413 THRU EQ SPON A 7.00 B.C.

ØØ

4X 0.433 THRUEQ SP ON A 4.75 B.C.

ØØ

8.00(20.3)

Ø 5.68(14.42)

Ø 6.25(15.87)

0.53(1.3

0.60(0.15)

4X 0.433 THRUEQ SP ON A 7.00 B.C.

ØØ

4X 0.433 THRUEQ SP ON A 7.25 B.C.

ØØ

CMXM100 CORNER ADAPTER

PAXM100 POLE ADAPTER

PXM100 PEDESTAL MOUNT

Note: Designed for use with a WXM100 wall mount.

Note: Designed for use with a WXM100 to mount a system to a vertical pole or a PXM100 to mount the system to a horizontal pole. Recommended pole diameter is 4 to 9 inches (10.16 to 22.86 cm).

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.

Page 92: Product Catalogue for Operation Spares

MODEL NUMBERS

Pelco, Inc. Worldwide Headquarters:3500 Pelco Way, Clovis, California 93612-5699 USAUSA & Canada Tel: (800) 289-9100 • FAX: (800) 289-9150International Tel: +1 (559) 292-1981 • FAX: +1 (559) 348-1120www.pelco.com

SYSTEM MODEL NUMBERS

COMPONENT MODEL NUMBERS

OPTIONAL ACCESSORIESTXB Series* Translator boards for AD Manchester, Hernis,

Bosch® (Philips®, Burle), Sensormatic®, TASS, Vicon™, and NTCIP™ protocols.

IPS-RMK Remote monitor kit. Includes TFT-LCD monitor, PDA handheld, cables, and carrying case. Allows viewing of camera video, local PTZ control, and system setup.

IPS-CABLE Remote monitor cable and software kit.IPS-RDPE-2* Remote data port. 24 VAC, wall/pole mount

video/data breakout box. Allows ground-level control/programming when used with the IPS-RMK.

VC-UTP Converts video for use with unshielded twisted pair (UTP); cannot be used simultaneously with TXB translator boards.

FS85011A Series* Factory-installed fiber transmitter sends one unidirectional composite video channel and one bidirectional data channel over on multimode or single-mode fiber optic cable.

EXAC Factory-installed increased safety (Ex e) potted cable interface and junction box with screw-down terminal for quick connection and easy installation.

*If TXB or FS85011A boards are installed, remote upload of system software will not be possible.

Model Format 24 VAC 100-240 VAC

22XColor

StandardNTSCPAL

IPSXM30C22-2IPSXM30C22-2X

IPSXM30C22-7IPSXM30C22-7X

With WiperNTSCPAL

IPSXM31C22-2IPSXM31C22-2X

IPSXM31C22-7IPSXM31C22-7X

23XDay/Night

StandardNTSCPAL

IPSXM30CBW23-2IPSXM30CBW23-2X

IPSXM30CBW23-7IPSXM30CBW23-7X

With WiperNTSCPAL

IPSXM31CBW23-2IPSXM31CBW23-2X

IPSXM31CBW23-7IPSXM31CBW23-7X

Pelco, the Pelco logo, B.O.S.S., and Coaxitron are registered trademarks of Pelco, Inc.LowLight is a trademark of Pelco, Inc.

All product names and services identified throughout this document are trademarks or registeredtrademarks of their respective companies. The absence of a trademark or registered trademark

from this document does not constitute a waiver of intellectual property rights.Product specifications and availability subject to change without notice.

©Copyright 2009, Pelco, Inc. All rights reserved

Power Module PTZ Camera Module

IPSXM-2 24 VACIPSXM-7 100 to 240 VAC

IPSXMPT30No Wiper

IPSXM30C22 Color (NTSC) camera (264X) no wiperIPSXM30C22X Color (PAL) camera (264X) no wiperIPSXM30CBW23 Day/Night (NTSC) camera (276X) no wiperIPSXM30CBW23X Day/Night (PAL) camera (276X) no wiper

IPSXMPT31With Wiper

IPSXM31C22 Color (NTSC) camera (264X) with wiperIPSXM31C22X Color (PAL) camera (264X) with wiperIPSXM31CBW23 Day/Night (NTSC) camera (276X) with wiperIPSXM31CBW23X Day/Night (PAL) camera (276X) with wiper

0.22

(0.5

5)

6.95

(17.

65)

6.16

(15.

65)

3.58

(9.0

9)

9.31 (23.65)

8.52 (21.65)

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.

0.31

(0.8

0)

Ø 0.28 (0.70)

0.91

(2.3

0)

0.10 (0.25)0.98 (2.50)

0.49 (1.25)

1.59 (4.05)

0.57 (1.45)

0.39 (1.00)

1.71

(4.3

5)

0.28

(0.7

0)

EXAC MOUNTING BRACKET

EXAC JUNCTION BOX

Page 93: Product Catalogue for Operation Spares

23.0 SAILOR_6301

Page 94: Product Catalogue for Operation Spares

SAILOR® 6300 MF/HFFor when it really counts

• Unique, next generation radiotelex software• Multiple control units• 150W-250W-500W versions• ThraneLINK

Instead of connecting the SAILOR 6300 MF/HF to an external GPS, the GPS input can be taken from the SAILOR 6110 mini-C GMDSS via ThraneLINK. Therefore, no additional cabling is needed.

More than GMDSSThe new SAILOR 6300 MF/HF is a high-end communications system in its own right. It complies with the requirement for MF/HF DSC Class A, which is part of the mandatory requirements for SOLAS vessels in all sea areas, and many national GMDSS requirements. It is developed and designed to meet the needs of professional mariners ensuring clear and powerful communication for a wide variety of vessels including high seas fishing vessels, merchant/offshore ships and workboats.

New ConnectionsThe SAILOR 6300 MF/HF can be quickly and easily connected to other critical GMDSS systems such as the SAILOR 6103 Alarm Panel. The SAILOR 6300 MF/HF features the new, user-friendly radiotelex software with a state-of-art MMI that works in combination with the new SAILOR 6006 Message Terminal. External loudspeakers, keyboards and printers can also be added easily.

Based on the same foundation of high reliability, ease of use and leading-edge functionality that has positioned SAILOR as the leading product in maritime communications, the SAILOR 6300 MF/HF DSC Class A offers much more than just a way to meet mandatory GMDSS requirements. In addition to being part of the innovative SAILOR 6000 GMDSS series, it is an integral part of a vessels communication system and a crucial tool when in distress and rugged, reliable, easy to use communications are a must.

The SAILOR 6300 MF/HF provides several unique new features such as message replay functionality – a first for MF/HF radios, and the ability to connect two control units. A highly efficient power amplifier with control hardware ensures high performance and reliable communication in the marine bands from 1.6 to 30 MHz in TX mode, and ensures constant and full output power on all ITU channels.

• SAILOR Replay – 240 seconds – First MF/HF to offer this feature• High quality graphical display - perfect night and day vision• 6W internal loudspeaker for excellent sound quality• Improved, intuitive and easy to operate menu structure

Page 95: Product Catalogue for Operation Spares

124

mm

107

mm

241 mm

273 mm 99 mm

38 mm

107 mm

Handset

SAILOR 630x MF/HF Control Unit

Handset

SAILOR6270

SAILOR 6208Connection Box

MF/HF DSCTelex Aerial

MF/HF

Switch Box

SAILOR 6103Alarm Panel SAILOR 6006 SAILOR H1252B

Keyboard

Telex optionGPS option

2182 select option

Other AlarmDistress Alarm

SAILOR636x

250W MF with 6 ch. ScanningDSC Watch Receiver

SAILOR638x

HF AerialCoupler

SAILOR 608xPower Supply

226

mm

62 mm

150W/250W 500W

6 x Ø6.50

200

164

164

12

145

76.5

271

75

4 x Ø8

1

350

360

430

391

238

200

400.5390.5

28310

224.

522

4.5

13.5

476

332360

350

3441

7

392

479

28

238

200

400.5390.5

28310

224.

522

4.5

13.5

476

332360

350

3441

7

392

479

28

6 x Ø6.50

200

164

164

12

145

76.5

271

75

4 x Ø8

1

350

360

430

391

Page 96: Product Catalogue for Operation Spares

GENERALOperating Modes Simplex and semi-duplex SSB telephony and DSC, TELEX AM broadcast receptionOperating temperature range -15°C to +50°CSupply voltage Nominal 24V DC floating With optional external AC power supply: 115/230V AC 50/60 Hz. Automatic changeover to DC in the absence of AC supplyPower consumption Rx, 60W (approx. at 24V DC) 150W 250W Tx, SSB speech: 175W 300W Tx, SSB two-tone: 300W 550W Tx, DSC/TELEX: 420W 600W Complies with ETSI 300-373 or better.User-programmable channels 199 frequency pairs with mode (1-199)User-programmable stations 40 stations with name, MMSI and station channel

RECEIVERFrequency range 150 kHz to 30 MHzAerial impedance 50Ω automatically matched by the aerial tuning unitSensitivity Aerial input for 10 dB SINAD, 50Ω aerial: SSB tel.: 0.7 µV AM tel.: 4 µV DSC/Telex: 0.7 µV Complies with ETSI 300-373 / 300 338.Audio output power 6W with less than 10% distortion

TRANSMITTEROutput power 150W PEP +/-1.4 dB into 50Ω voice. Reduction to 80W when continuously keyed single tone, with duty cycle greater than 55% during 1 min. Automatic power recovery after 1 min.

250W PEP +/-1.4 dB into 50Ω voice. Reduction to 100W when continuously keyed single tone, with duty cycle greater than 55% during 1 min. Automatic power recovery after 1 min.

500W 1.6 to 3.999 MHz 400W PEP +0/-1,4 dB into 50Ω voice. 4.0 to 29.999 MHz 500W PEP +/- into 50Ω voice. 3 dB reduction when continuously keyed single tone, with duty cycle greater than 55% during 1 min. Automatic power recover after 1 min. Power reduction Low approx.: 10WFrequency range ITU marine bands from 1605 kHz to 30 MHz

DSC-TELEX MODEMDSC Equipment class Class A

Protocols: DSC ITU-R M. 493.13, M. 541-6, and M. 1082.Telex ITU-R M. 625-2 (incl. M. 476-4), M. 490, M. 491-1, and 492-5 NBDP telex in ARQ, FEC and SEL FEC modes

Ship’s identity: DSC 9-digit identity numberTelex 5- and/or 9-digit identity numbers

Interfaces: Alarm DSC distress alarm interfaceNMEA NMEA 0183 interface for GPS equipmentIndustrial ethernet Line, Key Transceiver AF line input/output and external key interface. -10 to +10 dBm, 600ΩAUX alarm 2 Telex and non-distress/urgency DSC alarm output

DSC WATCH RECEIVERFrequency range Scanning: 2187.5 KHz, 4207.5 kHz, 6312.0 KHz, 8414.5 kHz, 12577.0 KHz, 16814.5 kHzAerial impedance 50Ω Complies with ETSI 300-373 or better.

AERIAL COUPLERFrequency range 1.6 MHz - 27.5 MHzAerial requirements 8-18 m wire and/or whip aerialAerial tuning Fully automatic with no presettingTuning speed 0.1 - 8 sec TypicalPower capability 330W PEP in 50Ω

DIMENSIONS AND WEIGHT 150W/250W 500WTransceiver Unit Width: 392 mm (15.4”) 392 mm (15.4”) Height: 445 mm (17.5”) 507 mm (20”) Depth: 127 mm (5”) 217 mm (5”) Weight: 19 Kg (41.9 lbs) 28 Kg (61.7”)Antenna Tuning Unit Width: 290 mm (11.4”) 401 mm (15.3”) Height: 500 mm (19.7”) 617 mm (24.3”) Depth: 80 mm (3.1”) 356 mm (14”) Weight: 3.3 Kg (7.3 lbs) 17 mm (37.5”)Control Unit Width: 240 mm (9.5”) 240 mm (9.5”) Height: 105 mm (4.1”) 105mm (4.1”) Depth: 100 mm (3.7”) 100mm (3.7”) Weight kg: 3.3 Kg (7.3 lbs) 3.3 Kg (7.3 lbs)

ThraneLINKThraneLINK is a sophisticated communication protocol that con-nects the SAILOR products in a network, offering important new opportunities to vessels. It provides facility for remote diagnostics and enables access to all the SAILOR products from a single point for service. This results in optimized maintenance and lower cost of ownership because less time is needed for troubleshooting and service. Installation is made easier as ThraneLINK automatically identifies new products in the system. The uniform protocol is an open standard which provides a future proof solution for all vessels.

Technical Data 150W, 250W and 500W

Page 97: Product Catalogue for Operation Spares

Thrane & Thrane A/S • [email protected] • www.thrane.com

A passion for innovation, proud traditions and our

legacy in maritime communication equipment provides

a unique platform for the development of reliable and

technologically advanced products for seafarers all over

the world.

Thus, Thrane & Thrane is the world’s leading manu-

facturer of global satellite and radio communications

equipment and we are proud to be able to offer a com-

plete selection of reliable, innovative and user-friendly

solutions for use at sea.

THE SAILOR® OF THE WORLDThe renowned SAILOR brand in itself represents more

than 50 years of experience in developing and refining

maritime communication. We are matching the

communication needs of the biggest ocean

going vessels, fish- and workboats of any kind and

exclusive leisure yachts and sailboats in every spot

of the world.

The portfolio includes maritime products from portable

radios, VHF and MF/HF, Inmarsat C terminals,

to complete GMDSS systems including LRIT and SSAS

solutions, and a full range of maritime satcom products

including Iridium, Fleet, FleetBroadBand, VSAT and

Satellite TV.

WORLDWIDE ON BOARD SERVICE Thrane & Thrane is famous for its World Class Service

program. A network of On Board Service Centers offers

on board service and repair all over the world.

Every measure is taken to provide efficient first-time-fix

support. We know that time is crucial for ship

management, and we are proud to be your reliable

service partner in any harbor at any time.

WORLD LEADER IN MARITIME COMMUNICATION

71-1

3217

8-A0

0 0

9.10

MBU

Subj

ect t

o ch

ange

with

out f

urth

er n

otic

e.

Page 98: Product Catalogue for Operation Spares

24.0 Sailor 6080 PSU

Page 99: Product Catalogue for Operation Spares

INSTALLATION & USER MANUAL

SAILOR 6081 Power Supply Unitand Charger

Page 100: Product Catalogue for Operation Spares

Appendix A: Technical specificationsAAAA

Tech

nica

l spe

cific

atio

ns

SAILOR 6080 Power Supply

The following table shows the electrical and environmental specifications of the Power Supply.

Specifications Value

Output power at 100 VAC - 240 VAC 300 W continuous370 W peak (2 min.)

Output power at 90 VAC - 100 VAC 270 W continuous333 W peak (2 min.)

DC output (nominal), without control, if not used in SAILOR 6081 with up to 4 SAILOR 6080.

31.2 VDC at 0 A29.3 VDC at 10 A28.7 VDC at 13 A

AC input voltage 115-230 VAC nominal, 100-240 VAC operating

Alarm in case of AC power failure

IP rating in high voltage (>42 V) IP 3X

IP rating in other areas IP 2X

IP rating when mounted vertically on a wall IP X2

Operating temperature -15° to +55° C

Storage temperature -40° to +80° C

Cooling No forced cooling required.

SAILOR 6080 Power Supply 39

Page 101: Product Catalogue for Operation Spares

Appendix A: Technical specifications

Survival temperature (power on) -40° to +80° C

Dimensions H: 46.5 mm, L: 354 mm, W: 265 mm

Weight Approx. 3.7 kg

Compass safe distance 30 cm

Specifications Value

40 SAILOR 6080 Power Supply

Page 102: Product Catalogue for Operation Spares

25.0 Sailor N163S

Page 103: Product Catalogue for Operation Spares

PARTS LIST (Fused for 220V from factory)

N163S, AC/DC Power supply T&T A/S N163S 801194xx

POS DESCRIPTION MANUFACTOR TYPE PART NO.

C5 CAPACITOR MKT 680nF 10% 63V ERO MKT 1818-468/065 11.186F2 FUSE 1AT 250V 5x20mm LITTELFUSE 218001 45.506R2 RESISTOR CONSTANTAN wire ø1.2 501194S1 Rocker Switch w. lamp, 10A/250VAC DPST Light Country/Legion LECR9Y2KDFT7F 43.057T1 TRANSFORMER MAINS 220V - 19V/7AAC Ulveco 6-0-28731A Art.Nr: EI-96-1001 22.120V4 DIODE BRIDGE 100V/25A SILITEK KBCP25-01(02,04,06,08,10) 27.110

Rectifier Board N163S T&T A/S 5-6-22605E / 4-0-22605D 622605

POS DESCRIPTION MANUFACTOR TYPE PART NO.

C1 Capacitor Electrolytic 4m7F 20% 40VDC Panasonic ECEC 1H P 472 C A 14.747C2 Capacitor Electrolytic 4m7F 20% 40VDC Panasonic ECEC 1H P 472 C A 14.747C3 Capacitor Electrolytic 4m7F 20% 40VDC Panasonic ECEC 1H P 472 C A 14.747C4 Capacitor Electrolytic 2200uF 20% 40VDC BC Components 2222 056 57222 14.748K1 RELAY DPDT 24VDC/1ADC TAKAMISAWA RY-24W-OH-K 78000044K2 RELAY 12VDC 1SH. 16A. relpol RM85-1011-25-1012 (35-1012) 21.012R1 RESISTOR PMF 100 OHM 5% 2W PHILIPS 2322 194 13101 04.175V1 DIODE Rectifier 100V/6A ON SEMICONDUCTORS MR751(752, 754, 756, 760)RL 25.220V2 DIODE BRIDGE 400VDC 1.5A G.I. 2KBP04/06/08/10 27.103V3 Diode Rectifier 100V/6A ON SEMICONDUCTORS MR751(752, 754, 756, 760)RL 25.220X1 Terminal Block 3 Poles 2.5mm2, CC=10mm SAURO MSM03002 81.190X2 Terminal Block 3 Poles 4.0mm2, CC=7.5mm SAURO MSQ03003 81.191X3 SOLDER LUG PCB VERSION VOGT AG 01015/Bz-Sn 82.005X4 Terminal Block 3 Poles 4.0mm2, CC=7.5mm SAURO MSQ03003 81.191X5 Terminal Block 3 Poles 4.0mm2, CC=7.5mm SAURO MSQ03003 81.191X6 Terminal Block 3 Poles 2.5mm2, CC=10mm SAURO MSM03002 81.190X7 SOLDER LUG PCB VERSION VOGT AG 01015/Bz-Sn 82.005X8 SOLDER LUG PCB VERSION VOGT AG 01015/Bz-Sn 82.005X9 SOLDER LUG PCB VERSION VOGT AG 01015/Bz-Sn 82.005F1 Fuse 10AF ATO BLADE RED PUDENZ 162.6185.5102 45.663XF1 Fuseholder 1POL ATO. 30A Littelfuse 178.6165.0001(.0002) 78.499

4-0-38423B

DIMENSIONS AND DRILLING PLAN

Technical specificationsINPUT: 110/127V AC Fuse T2A

220/237V AC Fuse T1A160VA 50/60Hz

OUTPUT: 24V DC 170W

Operating Temperature Range:-15°C to +55°C 93% Relative humidity.Storage Temperature:-20°C to +70°C 93% Relative humidity.

Power Supply wires110V AC - 2 x 1.5mm2

220V AC - 2 x 0.7mm2

24V DC - 2 x 6.0mm2

Absolute maximum voltage allowed on the batteryinput is 32V.

Weight 5 kg

Mains Voltage/Fuse Rating(Wired and fused for 230V from factory)

110V

5

110V

6

127V

7

0V

4

0V

3

slow

110V/2A

5

110V

6

127V

7

4

3

slow

127V/2A

5

110V

6

127V

7

4

3

slow

230V/1A

5

110V

6

127V

7

4

3

slow

237V/1A

0V

0V

110V

0V

0V

110V

0V

0V

110V

168mm 140mm

125mm

150mmFixing hole

4mm screws

centers for

Drilling plan

37mm

97mm

245mm

225mm

22901E

Solder strip on transformer

SAILOR N163S AC/DC Power Supply

TECHNICAL MANUAL

Thrane & Thrane A/S • [email protected] • www.thrane.com

Doc. no. M163SGB Issue: K/0952

Page 104: Product Catalogue for Operation Spares

26.0 Sailor SP3530

Page 105: Product Catalogue for Operation Spares

SAILOR SP3530 ATEX VHF

USER MANUAL

Page 106: Product Catalogue for Operation Spares

Emergency procedure

• Turn the knob at the top of the radio clockwise. The display lights up showing the last used channel and the battery level.

• Select channel 16 (Distress or Safety), press the 16/C key.

• Press the PTT and say: — “MAYDAY, MAYDAY, MAYDAY”, — “This is”..... ships name repeated three times — — “MAYDAY” — “This is”..... ships name and call sign, — The ship’s position in latitude and longitude or other reference to a known geographical location, — The nature of distress and assistance wanted, — Any other information which might facilitate the rescue. — “OVER”• Release PTT and listen for answer.

Page 107: Product Catalogue for Operation Spares

IMPORTANT INFORMATION

Safe use of ATEX equipment:

• Do not change the battery in wet or humid environments.

• Always keep battery connectors dry and clean.

• Use only with Sailor ATEX approved accessories. Alternatively ATEX approved accessories in compliance

with the accessory connector ATEX specification may beused.

• Do not change accessories in wet or humid enviroments.

• Do not charge the battery in hazardous area.

• For charge of battery use Part no: 403505A - ATEX CH3505 Compact Charger, Part no: 403507B - ATEX CH3507 Single Position Charger or Part no: 403508B - ATEX CH3508 Dual Position Charger

• Use only battery type Sailor B3503 or B3504.

• Do not use a mechanically damaged radio.

• Unpacking of the radio and accessories and the removal ofthe protective film in front of the display window must nottake place in the ATEX protected area.

99-127722-B0850

Page 108: Product Catalogue for Operation Spares
Page 109: Product Catalogue for Operation Spares

i

SP3530 ATEX VHF

Document number: TT 98-124306-D

Release date: December, 2009

Copyright: © 2009 Thrane & Thrane A/S. All rights reserved.

Trademark Acknowledgements

• SAILOR is a registered trademark of Thrane & Thrane A/S.

• Other product and company names mentioned in this manual may be trademarks or trade names of their respective owners.

Warranty limitation

IMPORTANT - The radio and batteries are sealed waterproof units. To create and maintain the waterproof integrity they were assembled in a controlled environment using special equipment. The radio and batteries are not user maintainable units, and under no circumstances should the units be opened except by authorized personnel. Unauthorized opening of the units will invalidate the warranty.

Disclaimer

Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies.

Manuals issued by Thrane & Thrane are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from the Thrane & Thrane Extranet at: http://extranet.thrane.com.

Thrane & Thrane is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source.

0952

Page 110: Product Catalogue for Operation Spares

ii

Precautions

Avoid water and salt in the I/O connector and keep it clean frequently.

Only use original Thrane & Thrane battery packs. Make sure they are clean and dry before attaching the transceiver. Be careful not to damage any gaskets.

Only use the original Thrane & Thrane charger for the rechargeable battery.

Be very careful when handling the Lithium batteries. With correct use they are safe but any misuse might cause dangerous situations.

Never short circuit the battery terminals, never expose the transceiver and the batteries to extreme temperature or fire and never use any kind of violence.

Avoid close contact between the antenna and parts of the human body. The top of the antenna must never be closer than 5 cm to the body when transmitting.

Do not submerge the transceiver more than 1 m for 30 minutes.

Keep the transceiver at least 0.3 m away from the magnetic compass.

0845

Page 111: Product Catalogue for Operation Spares

Training information

SAILOR SP3530 ATEX VHF is designed for "occupational use only". It must be operated by licensed personnel only.

The SP3530 complies with the FCC RF exposure limits for "Occupational Use Only".

• FCC OET Bulletin 65 Supplement C, evaluating compliance with FCC guidelines for human exposure to radio frequency electromagnetic fields.

• American National Standards Institute (C95.1) IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz.

• American National Standards Institute (C95.3) IEEE recommended practice for the measurement of potentially hazardous electromagnetic fields - RF and microwaves.

Correct use

For best performance, hold the radio vertically and 10 cm away from the head when talking into the microphone.

Warning! Your Thrane & Thrane VHF radio generates electromagnetic RF (radio frequency) energy when transmitting. To ensure that you are not exposed to excessive amounts of energy and thus to avoid health hazards from excessive exposure to RF energy, all persons must be at least 5 cm away from the antenna when the radio is transmitting.

iii

0845
Page 112: Product Catalogue for Operation Spares

iv

Page 113: Product Catalogue for Operation Spares

Chapter Introduction

Your ATEX VHF .....................................................................1

Performance ....................................................................... 2

Channels ............................................................................. 2

Chapter Operation

Controls ............................................................................... 5Keys and buttons ................................................................5The display .........................................................................7

Using the VHF ..................................................................... 8Basic functions ...................................................................8Other functions .................................................................. 11

Chapter BatteriesBattery level indication ......................................................15Removing and inserting the battery pack ...........................15The battery charger ...........................................................16Installing the charger ........................................................16Recharging the battery ......................................................17

Chapter Configuring the radio

Configuration mode ........................................................... 19Entering and using configuration mode ............................19List of configuration settings .............................................20

1

0845
Page 114: Product Catalogue for Operation Spares

Chapter Equipment and accessories

External equipment ............................................................27List of equipment .............................................................. 27Connecting external equipment ........................................ 27Impact on radio operation ................................................ 28Accessorie connector ........................................................ 28

Accessories ....................................................................... 29List of accessories ............................................................. 29Attaching and removing the belt clip .................................31Attaching the lanyard ........................................................31

Chapter TroubleshootingDisplaying errors .............................................................. 33

App. Technical specifications

Technical data SP3530 .......................................................35General ............................................................................ 35Transmitter ....................................................................... 36Receiver ........................................................................... 36

Battery life guidelines ........................................................38

Dimensional drawing, transceiver .....................................39

Dimensional drawing, chargers ........................................ 40

Declaration of Conformity ................................................. 42TÜV Certificate................................................................... 43

App. Attention

Goretex Membran ..............................................................47

2

0929
Page 115: Product Catalogue for Operation Spares

Chapter 1

Introduction

Your ATEX VHF

The SP3530 ATEX VHF is designed for flexibility in daily use. It connects easily to external equipment like headsets and fist mikes, making the SP3530 suitable for any noisy environment.

Main features:

Unique man machine interface, an excellent grip even with gloves, and large tactile buttons.

Display with red adjustable backlight which makes the display visible even at night.

Built-in “sleep” function, minimizing power consumption and improving battery lifetime.

Selectable 12.5 kHz narrow band or 25 kHz wide band operation.

Scrambling function for privacy calls.

CTCSS function for selective opening of Squelch.

A lanyard and belt clip included.

A huge accessory program comes with the SAILOR SP3500 series.

Please find the nearest SAILOR distributor on www.thrane.com.

10845

Page 116: Product Catalogue for Operation Spares

Introduction

Performance

For best performance of the transceiver keep the following in mind:

• Keep clear of metal environment.

• Hold the transceiver vertically and 10 cm from lips and push the PTT when transmitting.

• In receive mode carry the transceiver vertically with belt clips.

• To preserve battery power, adjust squelch to close the loudspeaker when there is no signal.

• If you are in a lifeboat keep the antenna as high as possible.

Channels

This radio operates default with the following channel designators (see also ITU-R M.1084-4), depending on the configuration (see the notes on the next pages):

1 9 17 25 60 68 77 85 US W-ch. CA W-ch.

2 10 18 26 61 69 78 86 W1 W8 W1

3 11 19 27 62 71 79 87 W2 W9 W2

4 12 20 28 63 72 80 88 W3 W10 W3

5 13 21 64 73 81 W4

6 14 22 65 74 82 W5

7 15 23 66 75 83 W6

8 16 24 67 76 84 W7

2

0845
Page 117: Product Catalogue for Operation Spares

Introduction

Channel modes

The notes in the following sections list the channel restrictions that apply for each channel mode.

For information on how to select a channel mode, see Entering and using configuration mode on page 19 and CHAN on page 20.

National frequency regulations shall always be respected and might restrict operation for this type of equipment.

International channels

Note:Tx power is limited to 1 W on channels 75 and 76.

US channels

Notes:

• Tx power is limited to 1 W on channels 13, 67 and 77.

• The channels 2, 4, 60, 61, 62, 75 and 76 cannot be selected.

• The Weather channels (US W-ch. in the channel table) can only be used in Rx direction.

• Channel 15 can only be used in Rx direction. Tx direction is blocked.

• The channels 1, 3, 5, 7, 18, 19, 21, 22, 23, 63, 64, 65, 66, 78, 79, 80, 81, 82 and 83 may only be used as simplex channels (and is marked A). Channel 20 may be used as semi-duplex and simplex as 20A.

3

0845
Page 118: Product Catalogue for Operation Spares

Introduction

Canadian channels

Notes:

• Tx power is limited to 1 W on channels 15, 17, 20, 65, 66 and 77.

• The channels 19, 22, 63, 75, 76 and 81 cannot be selected.

• The Weather channels (CA W-ch. in the channel table) can only be used in Rx direction.

• The channel 21 can only be used in Rx direction, marked 21B. Tx direction is blocked.

• The channels 4, 5, 7, 18, 19, 21, 22, 61, 62, 64, 65, 66, 78, 79, 80, 81 and 82 may only be used as simplex channels (and marked A). Channel 83 may be used as semi-duplex and simplex as 83A.

Inland Waters (BI) channels

Notes:

• Tx power is limited to 1 W on channels 15 and 17.

• ATIS function is enabled on all channels.

• Dual watch and Scanning modes are disabled.

ATIS is automatically transmitted after each transmission in Inland Waters. See ATIS on page 22 for information on how to program the call sign.

4

0845
Page 119: Product Catalogue for Operation Spares

Chapter 2

Operation

Controls

Keys and buttons

1. On/off/volume

2. Light/Lock

3. Push To Talk (PTT)

4. Up key

5. Down key

6. Hi/Lo output power

7. Squelch

8. Scan

9. Priority channel (16)/ Call channel

10. Loudspeaker/microphone

1

2

3

4

5

6

7

8

9

10

50845

Page 120: Product Catalogue for Operation Spares

Operation

Key presses

Pressing and holding certain keys gives access to additional functions, shown in the table below.

KeyShort press

(1 beep)Long press(2 beeps)

Extra long press

(3 beeps)

Show next available item in the list (up or down).

Default: Channel selection

Run through available items, or select tagged channels A ( ) or B ( ).

Run through available items if an A or B channel is tagged

Activate Squelch control (Adjust with up/down arrows).

Monitor function. Open Squelch completely. Set period of time in configuration mode.

1 press: Activate/terminate Dual/Triple watch.

2 presses: Activate memory scan.

Add/Delete channel from memory scan.

Toggle between high and low transmitter power.

Select channel 16. Select programmed Call channel.

Program Call channel.

6 0845

Page 121: Product Catalogue for Operation Spares

Operation

The display

The display holds various fields of information, explained below.

1. Current working channel.

2. Current channel mode.

3. “Lo”: Reduced transmitter power. Full transmitter power is not shown in display.

4. Dual/Triple watch activated.

5. Current working channel is marked for scanning.

6. Keypad is locked.

7. Battery level indicator.

8. Transmitting (Tx) /Receiving (Rx).

9. Accessory is connected.

10. Service line for various purposes. In this example the volume level.

11. Semi-duplex channel.

1

3

4 5 6

7

8

9

10

2

11

70845

Page 122: Product Catalogue for Operation Spares

Operation

Using the VHF

Basic functions

Switching the radio on and off

• To switch the radio on, turn the knob at the top of the radio clockwise. The display lights up showing the last used channel and the battery level.

• To switch the radio off, Turn the knob back counter-clockwise until it clicks.

Selecting the working channel

• To select channel 16 (Distress or Safety), press the 16/C key.

• To select the Call channel, use a long press on 16/C.

• To select among all available channels, press or on the keypad. For fast selection, press and hold or .

The display shows the currently selected channel. The bottom left corner of the display shows “Dup” if the channel is a semi-duplex channel.

Note Before using the radio, mount the antenna at the top of the radio. The antenna is delivered with the radio.

Note Long press on or can also be used to select preferred channels. For information on how to program preferred channels, see Configuring the radio on page 19.

8

0845
Page 123: Product Catalogue for Operation Spares

Operation

Activating a call

To activate a call to the selected channel, press and hold the PTT button on the side of the radio.

The radio transmits as long as the PTT button is pressed. A small Tx sign next to the channel num-ber indicates when the radio is in transmit mode.

Adjusting the volume

• To increase the volume, turn the on/off knob at the top of the radio clockwise.

• To decrease the volume, turn the knob counter-clockwise.

The display shows the level of the volume, e.g. “VOL 5”, while it is adjusted.

Using Squelch control

• To activate Squelch control, press the SQ key.

• To set the Squelch level, press (closing) or (opening). The display shows the Squelch level while it is adjusted, e.g. “SQ 5”.

Adjusting the display backlight

• To turn on the backlight, press the Light/Lock button on the side of the radio.

• To adjust the backlight level, press or within 3 seconds after turning on the light.The display shows the level while it is adjusted, e.g. “DIM MED”.

9

0845
Page 124: Product Catalogue for Operation Spares

Operation

Using Dual/Triple watch

• To activate Dual/Triple watch, press the SCN key.The display shows “Dual” or “Tri” at the top and “16” at the bottom right. The radio toggles between the selected channel and channel 16 in Dual watch. In Triple watch, the radio shifts between channel 16, the call channel and the selected channel.To select whether the SCN key should activate Dual or Triple watch, refer to Configuring the radio on page 19.

• To terminate Dual watch, press SCN again.

Scanning channels

• To activate scanning memory, press 2 times SCN within 2 seconds. During scanning, the display shows “SC” in the channel field. The radio toggles between channel 16 and each of the channels marked for scanning.

• To terminate scanning, press SCN once.

Changing the transmitter power

To change the transmitter power, press the Hi/Lo key. The display shows “Lo” when power is set to low. Otherwise maximum power is used.

Locking the keypad

• To lock the keypad, press and hold the Light/Lock button. The display shows a key symbol when the keypad is locked.

• To unlock the keypad, press and hold the Light/Lock button again.

10

0845
Page 125: Product Catalogue for Operation Spares

Operation

Other functions

Programming the Call channel

To program the Call channel, do as follows:

1. Press and hold 16/C until the current Call channel number is flashing.

2. Select the channel with or .

3. Press 16/C to confirm within 3 seconds.

Programming the scanning memory

To add a channel to the scanning memory, select the channel and then press and hold the SCN key until the display shows MEM at the top.

To remove a channel from the scanning memory, select the channel and then press and hold the SCN key until the MEM sign disappears from the display.

Low power operation

The radio can be operated in low power mode. In this mode battery life time is dramatically increased. Up to the first second of a received call might be lost if this mode is selected. Refer to SLEEP on page 21.

Continuous Tone Coded Squelch System

Selective squelch opening by sub-tone detection (CTCSS) can be enabled, using the configuration mode (see CTCSS on page 24). Please note that if the radio is operating with CTCSS on a channel, and a carrier is received, it may not be recognized in the loud speaker if the matching sub-tone is not detected. For this reason, be very careful not to use CTCSS programmed channels in emergency situations. For the same reason

110845

Page 126: Product Catalogue for Operation Spares

Operation

transmitting is prohibited (reporting "BUSY") if a (silent) carrier containing any sub-tone is active on the channel while pressing PTT.Channels programmed with CTCSS will have a clear identification in the service field, e.g. "CTCSS 22", while selected. Not all channels are allowed for CTCSS use.

In maritime channel modes CTCSS is automatically disabled when

• Product is turned off

• A new channel is selected

For private channels and ALT channel mode, the feature will remain until manually removed.

Scrambler

On channels where it is allowed, you can set up voice scrambling, using configuration mode (see SCRM on page 25).

Please note that if the radio is operating with scrambling on a channel, it is impossible to communicate with other radios that are not programmed with the same scrambler code. For this reason, be very careful not to use scrambled channels in emergency situations. Scrambled channels will have a clear identification in the service field, e.g. "SCRM 3", while selected. Not all regions allow the use of voice scrambling.

In maritime channel modes scrambling is automatically disabled when

• Product is turned off

• A new channel is selected

For private channels and ALT channel mode, scrambling will remain until manually removed.

12

0845
Page 127: Product Catalogue for Operation Spares

Operation

Narrow band operation

The radio is prepared for narrow band operation. If narrow band operation is selected (see BAND on page 25), the number of channels are doubled in the maritime channels, according to international recommendations. Refer to the channel table in Channels on page 2. Channels are clearly identified with a preceding 4- or 2-digit, while operating in narrow band mode. Narrow band radios will not always be completely compatible with wide band operating radios.

For single narrow band configured private channels or "ALT" channels, an “n” is displayed next to the channel designator.

Note Prior to any initiation of scrambling, the operator must always identify the calling station in clear voice (unscrambled) on that channel. Use of scrambling may also be restricted by national laws.

130845

Page 128: Product Catalogue for Operation Spares

Operation

14 0845

Page 129: Product Catalogue for Operation Spares

Chapter 3

Batteries

Battery level indication

When the battery level is low, you should recharge the battery.

The radio display shows the battery status. When the battery symbol is empty and flashing, the battery should be recharged as soon as possible.

Removing and inserting the battery pack

To remove the battery pack, do as follows:

1. Open the safety lock as shown.

2. Remove the battery.

To insert the battery pack, attach the battery and then close the safety lock.

If the radio is not used for several weeks it is recommended to store the radio and battery separated to reduce self discharge of the battery.

1

2

15

0845
Page 130: Product Catalogue for Operation Spares

Batteries

The battery charger

The chargers has two compartments.

CH3505

• A compartment for recharging the battery alone or while attached to the radio.

CH3507

• A rear compartment only for storing a spare battery. It does not have a charger function.

• A front compartment for recharging the battery alone or while attached to the radio.

CH3508

• It is possible to charge a battery in rear compartment simultaneously with the radio/battery in front.

Installing the charger

Mounting the charger

There are several options for mounting one or more chargers on a table or a wall.

For information on dimensions and screw positions, refer to Dimensional drawing, charger on page 40.

16

0845
Page 131: Product Catalogue for Operation Spares

Batteries

When mounting the charger, make sure it is placed in a dry place and away from direct sunlight. The charger is not waterproof.

Connecting to power

The charger can be supplied from DC or from AC using an AC/DC converter.

DC: Connect the 12-24VDC Connection Cable between the DC supply and the connector on the underside of the charger.

AC: Connect the AC/DC converter to the connector on the underside of the charger. Then connect the AC/DC converter to the AC outlet.

Recharging the battery

To recharge the battery, place the radio with battery or the battery alone in the front position of the charger cradle.

If the radio cannot turn on due to complete discharged battery, then turn of the radio and place it in the charger or charge the battery alone.

The light indicators on the charger cradle show the status as follows:

• Green light: Power is connected to the charger.

• Slow red flash: Charging in progress.

• Quick red flash (twice per second): Charging error, e.g. battery defect or temperature out of range.

• Steady red light: Charging completed. Trickle charge mode.

17

0845
Page 132: Product Catalogue for Operation Spares

Batteries

Charging time with emtpy battery: VHF off approx. 4 hours, VHF on: approx. 5 hours.

The battery indicator on the radio display indicates if the radio is placed in the charger while radio and charger are both powered.

18

0845
Page 133: Product Catalogue for Operation Spares

Chapter 4

Configuring the radio

Configuration mode

Entering and using configuration mode

• To enter configuration mode, press and hold the Light/Lock button while turning on the radio.The bottom line of the display shows the current menu item/setting.

• To exit configuration mode, turn off the radio or press any key except , and the Light/Lock button.

Using the PTT button or leaving the radio inactive for 10 seconds also causes the radio to exit configuration mode.

• To change a setting, press or .

• To confirm the current setting and go to the next menu item, press the Light/Lock button.

Note The radio is not operational in configuration mode.

190845

Page 134: Product Catalogue for Operation Spares

Configuring the radio

List of configuration settings

The following settings are available in configuration mode.

Name Values Description

LIGHT MAN Only Light/Lock button activates the backlight.

KEY All keys and buttons, except PTT and volume control, activate the backlight.

CHAN INT International channels.

US US channels.

CA Canadian channels

BI Inland waterways. ATIS and ATIS killer is enabled. All multiple watch is disabled.

ALT Custom defined.

BEEP MAX Status click/beep sound on key press, long press (settings/programming saved) and battery alarm. Maximum level.

MIN Status click/beep sound on key press, long press (settings/programming saved) and battery alarm. Minimum level.

OFF All beeps off.

VER X.XX.XX Software version. Read-only.

BAT X.XX Battery voltage (V). Read-only.

TEMP XX.X Temperature (°C). Read-only.

20 0845

Page 135: Product Catalogue for Operation Spares

Configuring the radio

SLEEP ON Enable sleep mode (to minimize power consumption).

Sleeps for periods of 1 second after 15 seconds of idle mode. Idle mode is: no signal detected and no operation of the radio.

OFF Disable sleep mode.

CONTRST 1, 2, 3, 4, 5 Contrast. 1 = lowest and 5 = highest.

SHANG OFF Off. Resumes scanning when signal disappears.

4, 6, 8, 10 Scan hang time (in seconds) on an active receiving working channel. The time is measured from signal detected - remains on channel even if signal disappears.

RESCN OFF Automatic resume deactivated.

3, 6, 10, 15, 20, 25, 30

Scanning/watch can be automatically resumed after this time (seconds) if previously terminated with PTT.

WTCH DUAL Single press on the SCN key activates Dual watch.

TRI Single press on the SCN key activates Triple watch. If no CALL channel is programmed, “Dual” watch is activated.

Name Values Description

210845

Page 136: Product Catalogue for Operation Spares

Configuring the radio

SQ TIME A long press on SQ opens squelch. The squelch level resumes to setting 3 seconds after SQ is released.

MAN A long press on SQ opens squelch. The squelch level resumes to setting as soon SQ is released.

WORK ON If the distress or call channel is selected using the 16/C key, any push on or will select the working channel active when 16/C was pushed.

OFF If on a distress or call channel, any push on or will select the channel next to the

displayed channel.

ATIS NONE Default state if not programmed.

Push to go into programming mode.

READ The ATIS call sign is programmed and available for read-out.

Push to read the programmed ATIS value.

DDDADDDD ATIS Call sign read-out. Read-only after programming once. Changing or clearing the Call sign after programming is only possible via the service interface.

Name Values Description

22

0845
Page 137: Product Catalogue for Operation Spares

Configuring the radio

1 _ _ _ _ _ _ _ _ 0-9 In ATIS programming mode:

• Select the digit position with the Light/Lock button.

• Select the digit with or .

1 2 _ _ _ _ _ _ _ 0-9

1 2 3 _ _ _ _ _ _ 0-9

1 2 3 A _ _ _ _ _ A-Z

1 2 3 A 5 _ _ _ _ 0-9

1 2 3 A 5 6 _ _ _ 0-9

1 2 3 A 5 6 7 _ _ 0-9

1 2 3 A 5 6 7 8 _ 0-9

1 2 3 A 5 6 7 8 Press to confirm programming.

Note: All digits must be programmed.

PREFA OFF Remove tag “A” for current working channel.

ON Tag current working channel with “A”. If another channel was previously tagged “A”, this is overruled.

• The working channel can now be selected with a long press on .

PREFB OFF Remove tag “B” for current working channel.

ON Tag current working channel with “B”. If another channel was previously tagged “B”, this is overruled.

• The working channel can now be selected with a long press on .

Name Values Description

23

0845
Page 138: Product Catalogue for Operation Spares

Configuring the radio

SUBC OFF SUBC disabled. Squelch opens on all received signals.

1, 2, ..., 38 Sub-tone carrier ID.

Squelch opens if the received signal contains the desired subtone. During transmission the sub-tone with the corresponding ID is generated.

Two radios on the same channel and with the same sub-tone ID, can reduce unwanted incoming traffic from other users on the same channel.

CTCSS OFF CTCSS disabled.

ON Activate CTCSS on working channel. Two radios on the same channel and with SUBC enabled, can have a certain level of privacy.

Note that if you choose this option, the radio immediately exits configuration mode and starts CTCSS on the working channel.

GROUP SEL Selective Mode. Squelch opens only if the programmed sub-tone is received in the signal.

ANY Squelch opens on reception of any of the 38 sub-tones.

Name Values Description

24

0845
Page 139: Product Catalogue for Operation Spares

Configuring the radio

SCODE OFF No scrambler code is assigned to the channel (selecting “ON” in the SCRM setting will have no effect).

1, 2, 3, 4, 5, CC

A selection between 5 fixed sets of scrambler characteristics, and a custom code (CC), can be assigned to the channel.

Note that the custom code can be defined in the service interface.

SCRM OFF Scrambler disabled.

ON Activate scrambling on working channel. Two radios on the same channel and with scrambling enabled, can have a certain level of privacy.

Note that if you choose this option, the radio immediately exits configuration mode and starts scrambling on the working channel.

BAND 25.0 Wide band operation selected.

12.5 Narrow band operation selected.

• Intercepted channels will be denoted 2XX.

• Standard maritime channels will be denoted 4XX.

Name Values Description

25

0845
Page 140: Product Catalogue for Operation Spares

Configuring the radio

26

Page 141: Product Catalogue for Operation Spares

Chapter 5

27

Equipment and accessories

External equipment

List of equipment

The following equipment can be connected to the radio:

• SAVOX C400AV Push-To Talk unit

• SAVOX C500 Fist Mike

• SAVOX NC/400 Noise-com

• SAVOX HC-E Helmet-com

• SAVOX K53004 Helmet unit

• Peltor MT7H79 Headset

We recommend to remove all accessories during emergency use.

All accessories listed might be used when body worn.

Connecting external equipment

Connect the dedicated interface cable between the external equipment and the top connector on the radio.

Interface cable Order number

SAVOX C400AV 403500-942

SAVOX C500 403500-944

Peltor FL5261 403500-952

0952

Page 142: Product Catalogue for Operation Spares

Equipment and accessories

28

When external equipment is connected to the radio, the right side of the display will show a headset.

Impact on radio operation

The external equipment can have a built-in PTT button, speaker and microphone. Thus a connection has per default the following impact on the radio operation:

• If a speaker or earpiece is built into the detected external equipment, the sound device of the external equipment is used, and the internal radio speaker is disabled.

• The external accessory microphone is selected as audio input device, when the external PTT button is pressed. The transceiver microphone is used as audio input device when the transceiver PTT button is pressed.

• This behaviour can be changed in the service tool.

Accessorie connector

Pin 1. Loudspeaker,

minimum 8 ohm impedance.

Pin 2. Accessory power,

3.5V maximum 13mA.

Pin 3. Microphone input,

Ri = 2.2kohm, 3V phantom power.

Pin 4. GND

0945

Page 143: Product Catalogue for Operation Spares

Equipment and accessories

29

Accessories

List of accessories

The following accessories are delivered with your radio:

Batteries, charger, AC/DC Converter and 12VDC Connection are described in Batteries on page 15.

To mount the antenna, simply screw it into the threaded bush at the top of the radio.

Use of lanyard is only for hand held operation. Put it around the wrist to prevent dropping the radio.

Accessory Part number

ATEX Secondary battery (blue, rechargeable), B3504 403504A

ATEX Compact Charger, CH3505 403505A

AC/DC converter, length 150cm (100-240V~ /12VDC out) 88-125538

12-24VDC Connection cable, length 150cm 37-124381

Belt clip 62-124320

Antenna 88-124370

Lanyard 41-124375

User Manual (this manual) TT 98-124306

0945

Page 144: Product Catalogue for Operation Spares

Equipment and accessories

Accessories you may buy

Leather Case

Warning!

The display must always be kept away from the body to reduce the RF explosure when body worn.

Accessory Part number

ATEX Charger, CH3507 403507B

ATEX Dual Position Charger CH3508 403508B

ATEX Leather Case with shoulder strop 403500-207

30 0845

Page 145: Product Catalogue for Operation Spares

Equipment and accessories

Attaching and removing the belt clip

To attach the belt clip, slide the belt clip upwards into the rails at the back of the radio until it locks.

To remove the belt clip, press the projection at the top of the belt clip to release the lock and slide the belt clip downwards out of the rails.

Attaching the lanyard

Do as follows:

1. Take the lanyard through the eye at the top of the radio.

2. Put one end of the lanyard through the loop at the other end of the lanyard and pull to tighten.

Release lock

Top view

31

0845
Page 146: Product Catalogue for Operation Spares

Equipment and accessories

32

0845
Page 147: Product Catalogue for Operation Spares

Chapter 6

Troubleshooting

Displaying errors

Some errors result in an error message in the display. These error messages are listed below.

Display text Problem Type Actions

ErrEMPTY BAT

The battery voltage is below a critical level, where further operation would damage the battery.

Severe. Radio is non-functional.

Change/recharge the battery.

ErrHW ERR

Hardware error. Severe. Radio is non-functional.

Service required.

ILLEGAL

Context fails operation. This text will appear on the following occasions:

• Multiple watch is selected on channel 16, or in channel regions where it is not allowed.

• High power is selected on a channel where it is prohibited.

• Transmission on blocked channels

Fail operation

Consider operation in a different context.

330845

Page 148: Product Catalogue for Operation Spares

Troubleshooting

34 0845

Page 149: Product Catalogue for Operation Spares

Appendix A

Technical specifications

Technical data SP3530

General

Item Specification

Rx frequency range, landmobile 148.000 - 174.000 MHz

Tx frequency range, landmobile 148.000 - 174.000 MHz

Rx frequency range, maritime 155.000 - 163.425 MHz

Tx frequency range, maritime 155.000 - 161.450 MHz

Modulation

25 kHz

12.5 kHz

16K0G3E

8K50G3E

Power supply 7.2 VDC Li battery

Current drain at 2 W Tx 1 A

Current drain at 0.4 W Tx 0.7 A

Current drain Rx max audio 0.25 A

Antenna port 50 ohm

Battery Lithium-Ion, 1800 mAh rechargeable

Operating temperature -20°C to +55° C

350845

Page 150: Product Catalogue for Operation Spares

Technical specifications

Transmitter

Receiver

Water ingress protection IP67

Frequency stability Better than ±0.7 kHz

Weight with emergency battery 370g

Item Specification

RF output power 2 W /1 W

RF output power, Canada 1.7 W ±0.7 dB / 0.8 W ±1 dB

Max deviation

25 kHz

12.5 kHz

±5 kHz

±2.5 kHz

Spurious emission < 0.25 uW

Adjacent channel power

25 kHz

12.5 kHz

> 70 dB

> 60 dB

Item Specification

Sensitivity (20 dB SINAD) -117 dBm typical

Item Specification

36

0740
Page 151: Product Catalogue for Operation Spares

Technical specifications

Intermodulation

25 kHz

12.5 kHz

> 68 dB

> 65 dB

Spurious response > 70 dB

Adjacent channel selectivity

25 kHz

12.5 kHz

> 70 dB

> 60 dB

Audio output, internal 0.25 W at 10% dist.

Audio output, external 0.25 W/8 ohm

Item Specification

370740

Page 152: Product Catalogue for Operation Spares

Technical specifications

Battery life guidelines

During daily use, always keep the battery fully charged and away from hot areas.

Keep the battery terminals dry and clean.

Never discharge beyond the specifications of the battery.

Operation/Standby time depends on usage. Generally, the more the radio is transmitting, the faster it will drain the battery. Also, the “Hi” power setting will drain the battery faster than the “Lo” setting.

Approximate figures are:

• A battery can be stored for 4 to 6 month at 25°C if charged to 40%.

• The battery will normally last for 5 to 9 hours of use on a fully charged battery.

Note New batteries should be placed in the charger CH3505, CH3507 or CH3508 for minimum 12 hours first time.

38

0929
Page 153: Product Catalogue for Operation Spares

Technical specifications

Dimensional drawing, transceiver

280

5566

390845

Page 154: Product Catalogue for Operation Spares

Technical specifications

Dimensional drawing, chargers

CH3505

37

40

4422

46.8

30.5

Mounting Possibillities

Desktop mounting, top view Wall mounting, rear view

70.4

87

80

40 0845

Page 155: Product Catalogue for Operation Spares

Technical specifications

Mounting Possibillities

Desktop mounting, top view Wall mounting, rear view

CH3507 and CH3508

410845

Page 156: Product Catalogue for Operation Spares

Technical specifications

42 0845

Page 157: Product Catalogue for Operation Spares

Technical specifications

R&TTE

Doc. no TT99-128497-B

Thrane & Thrane A/SDeclaration of Conformity with R&TTE Directive

The undersigned of this letter declares that the following equipment complies with thespecifications of EC directive 1999/5/EC concerning Radio & Telecommunications TerminalEquipment.

Equipment included in this declarationSAILOR SP3530 ATEX Portable maritime VHF radiotele- PN = 623530A

phone (non GMDSS) orATEX Portable VHF radiotelephonefor landmobile use

SAILOR B3503 ATEX Primary Battery PN = 403503ASAILOR B3504 ATEX Rechargeable Li-Ion Battery PN = 403504ASAILOR CH3505 Battery Compact Charger for ATEX PN = 403505ASAILOR CH3507 Battery Charger for ATEX PN = 403507BSAILOR CH3508 Dual Battery Charger for ATEX PN = 403508B

AC/DC Adapter PN = 88-125538

Equipment ApplicabilitySAILOR SP3530 is a simplex/semi-duplex handheld VHF radiotelephones designed formaritime and landmobile communication within the frequency range 148 MHz to 174 MHz.

DeclarationSAILOR SP3530 conforms to the RTTE directive with respect toArticle 3(1)(a) the protection of health and safetyArticle 3(1)(b) electromagnetic compatibility requirementsArticle 3(2) effective use of the spectrum and avoidance of harmful interference

Which is shown by conforming to EU harmonized standard EN 301 178-2, EN 60945-Ed.4.0, EN 60950-1, EN 300 698-3 and EN 300 086-2.

ManufacturerThrane & Thrane A/S Lundtoftegårdsvej 93D, DK-2800 Kgs. Lyngby, Denmark

Porsvej 2, DK-9200 Aalborg SV, Denmark

Place and DateAalborg, 23. January 2009

Chief Financial OfficerSvend Åge Lundgaard Jensen

Page 1 of 1

Thrane & Thrane A/S · Lundtoftegårdsvej 93D · DK-2800 Kgs. Lyngby · Denmark

T +45 39 55 88 00 · F +45 39 55 88 88 · [email protected] · www.thrane.com

Bank: Danske Bank · Comp. reg.: 65 72 46 18 · VAT: DK-20 64 64 46

Declaration of Conformity

430929

Page 158: Product Catalogue for Operation Spares

Technical specifications

44 0929

Page 159: Product Catalogue for Operation Spares

Technical specifications

450929

Page 160: Product Catalogue for Operation Spares

Technical specifications

46 0929

Page 161: Product Catalogue for Operation Spares

Appendix B

Attention

Goretex Membran

To keep the ATEX VHF watertight, is it very important that the goretex membran behind the label under no circumstances must be damaged or removed.

470929

Page 162: Product Catalogue for Operation Spares

Attention

48 0845

Page 163: Product Catalogue for Operation Spares
Page 164: Product Catalogue for Operation Spares

TT-98-124306-D Issue: D/0952

Thrane & Thrane A/S • [email protected] • www.thrane.com

Page 165: Product Catalogue for Operation Spares

27.0 Sailor 6080 PSU

Page 166: Product Catalogue for Operation Spares

INSTALLATION & USER MANUAL

SAILOR 6081 Power Supply Unitand Charger

Page 167: Product Catalogue for Operation Spares

Appendix A: Technical specificationsAAAA

Tech

nica

l spe

cific

atio

ns

SAILOR 6080 Power Supply

The following table shows the electrical and environmental specifications of the Power Supply.

Specifications Value

Output power at 100 VAC - 240 VAC 300 W continuous370 W peak (2 min.)

Output power at 90 VAC - 100 VAC 270 W continuous333 W peak (2 min.)

DC output (nominal), without control, if not used in SAILOR 6081 with up to 4 SAILOR 6080.

31.2 VDC at 0 A29.3 VDC at 10 A28.7 VDC at 13 A

AC input voltage 115-230 VAC nominal, 100-240 VAC operating

Alarm in case of AC power failure

IP rating in high voltage (>42 V) IP 3X

IP rating in other areas IP 2X

IP rating when mounted vertically on a wall IP X2

Operating temperature -15° to +55° C

Storage temperature -40° to +80° C

Cooling No forced cooling required.

SAILOR 6080 Power Supply 39

Page 168: Product Catalogue for Operation Spares

Appendix A: Technical specifications

Survival temperature (power on) -40° to +80° C

Dimensions H: 46.5 mm, L: 354 mm, W: 265 mm

Weight Approx. 3.7 kg

Compass safe distance 30 cm

Specifications Value

40 SAILOR 6080 Power Supply

Page 169: Product Catalogue for Operation Spares

28.0 SAC SA25 50 100

Page 170: Product Catalogue for Operation Spares

SA Series 25/50/100

SA25, 50 and 100 NDB Transmitter Series With Auto-tuning Coupler for:

Airports using Non-Directional Beacons for instrument approach.

Aviation Authorities such as FAA, CAA, Military, etc.

Offshore platforms requiring helicopter and/or crew boat navigation.

DGPS Reference Station Transmitter.

Bringing your pilots in safely for more than forty-fi ve years . . .

Southern Avionics Company

P.O. Box 5345Beaumont, TX 77726-5345 U.S.A.

Phone: (409) 842-1717 • Toll Free: 1-800-648-6158 • Fax: (409) 842-2987Email: [email protected]

www.SouthernAvionics.com

SAC Services:

On-site or telephone Technical SupportInstallation SupervisionFactory or on-site TrainingSite Planning AssistanceSite CommissioningSite Acceptance Test

••••••

Page 171: Product Catalogue for Operation Spares

SA

Series

Why buy from Southern Avionics? . . . Because we’ve been recognized as the foremost manufacturer of

NDBs in the world for more than 45 years of superior quality production and relentless commitment to

long-term customer satisfaction.

SA 25, 50, 100 Specifi cations (Meets applicable requirements of ICAO, FCC and FAA.)

Type of Emission NON, A2A, A3E (Optional) or any combination. GID (with optional GPS beacon modulator)

Frequency 190-535 kHz, (optionally 190 to 1800 kHz in three system bands of 190 to 535 kHz, 520 to 1250 kHz, and 1500 to 1800 kHz). Synthesized (fi eld programmable), no additional parts needed within the band.

Power Output 5 to 100 watts models

Radiated Harmonics Radiated harmonics are better than 63 dB below carrier (100 watt model).

Modulation Switching modulator / regulator, 0-95%, internal 400 or 1020 Hz, eight baud Keyer, 7 WPM.

Input Power 115/230V +/-15%, single phase 50 - 60 Hz. or optional 24VDC or both with switch over to batteries. Nominal input power is 180W at 100W carrier and keying at 95% modulation.

Load Center / Battery Charger

Optional item provides AC and DC mains circuit breaker, 10 Amp fast/fl oat charge battery charger, and AC convenience outlet. Two (2) each 12VDC deep cycle marine type batteries will operate the SA100 at 85% power for 12 hours.

Metering Power output, refl ected power, PA voltage, PA current, percent modulation, audio input level.

Working Conditions Continuous unattended operation, -50° to +70°C, 0-100% non-condensing humidity. Dimensions 32”H, 21”W and 15”D.

Monitoring Automatic shutdown if tone, modulation, power or VSWR drift beyond a user adjustable level. With a dual system, a shutdown signal initiates a transfer from the primary transmitter to the secondary transmitter.

Dimensions SA Dual: 31.75” H x 21” W x 15” D (80.6cm x 53.3cm x 38.1cm)SA Single: 24.12” H x 21.12” W x 16.5” D (61.1cm x 53.6cm x 41.9cm)

PC-10002 Auto-tuning Antenna Coupler

SA Series Antennas & Optional EquipmentOffshore Options:

34’ / 10m Mast34” / 10m WhipHelipad

Land OptionsLand OptionsLand Opt :34’ / 10m Mast50” / 15m, 60’ / 18m, 90’/ 27m Guyed Mast60’ / 18m, 90’ / 27m Symmetrical TAnti-ice InsulatorsObstruction Lights

•••

•••••

Input Impedence 50 ohms

Load Impedence 2 to 25 ohms resistance, 200 to 1500 pF capacitance

Frequency 190 to 625 kHz (up to 1800kHz depending on model), with a 200 to 1500 pF load

Power Input Up to 500 watts peak, 100 watts carrier

Metering Antenna current and tuning. Single meter with four position switch for OFF, TUNE, HIGH and LOW tuning

Tuning Large coil with coarse taps, fi ne taps and a rotating shorted ring controlled by the autotune system

Lightning Protection Lightning gap at the antenna terminal. Special pas-sive circuit that protects the transmitter fi nal amplifi er from lighting transients.

Working Conditions Continuous unattended operation, -50° to +70°C, 0 to 100% humidity. Designed for outdoor mounting.

Dimensions 24.37” H x 21” W x 17.5” D(61.9cm x 53.3cm x 44.4cm)

25/50/100

H

FUEL

Technical Support Packages Available

Input ImpedenceLoad Impedence

Frequency

Power InputMetering

Tuning

Lightning Protection

Working Conditions

Dimensions

SA Series Enhancement OptionsMonitor Alarm Receivers -provides off the air monitoring of the NDB signal from a remote location

24VDC Load Center/Battery Chargers (see text on brochure)

DGPS MSK Interface PCB -provides the interface between the NDB and the DGPS modulator. The MSK signal from the DGPS Beacon Modulator contains the main carrier and differential GPS correctiondata. The MSK signal is used to generate the RF signal in low frequency (283.5 - 325 kHz) Radio Beacons. The MSK signal has no effect on normal NDB operation (Morse code identifi er, generated by amplitude modulating the carrier).

Serial Converter Kit -converts the SA serial protocol to standard RS232 protocol and allows the user to connect the SA through other RS232 devices like modems or the SLF81014 Fiber extender

Multi-Mode fi ber Optic Link allows the extension of remote control capabilities up to 2.5 miles (3.25 km).

Page 172: Product Catalogue for Operation Spares

29.0 SAC PC1000C

Page 173: Product Catalogue for Operation Spares

BOX 5345, BEAUMONT, TEXAS 77726-5345 USA; PHONE (409) 842-1717; IN USA 1-800-648-6158; FAX (409) 842-2987

Southern Avionics Company's PC1000C/IP66 Autotuning Antenna Coupler.

PC1000C/IP66 Autotuning Antenna Coupler

Input Impedance: 50 ohms. Load Impedance: 2 to 25 ohms resistance, 200 to 1500 pF capacitance. Frequency: 190 to 625 kHz with a 200 to 1500 pF load. Power Input: Up to 500 watts peak, 200 watts continuous. Metering: Antenna current and tuning. Single meter with a four position switch for OFF, TUNE, HIGH and LOW tuning. Tuning: Large coil with coarse taps, fine tapes and a rotating shorted ring controlled by the autotune system. Lightning Protection: Lightning gap at the antenna terminal. Special passive circuit that protects the transmitter final amplifier from lighting transients. Working Conditions: Continuous unattended operation, -50° to +70°C, 0-100% noncondensing humidity. Designed for outdoor mounting. Dimensions 25"H, 21"W and 16"D. Enclosure is IP66 certified.

Page 174: Product Catalogue for Operation Spares

30.0 PACIFIC 6W SPLITTER

Page 175: Product Catalogue for Operation Spares

PACIFIC POWER PASS SPLITTER* All ports with Power Pass* Frequency : 5-2400MHz* Impedance : 75 ohms all ports* Power pass : Max. 1A, 3.0V* Grounding Terminal Provided* RF Shielded Zinc Die Cast Housing, Nickel-Plated

Item Insertion Loss (dB) Mutual Isolation (dB) Return Loss (dB)(MHz) 5 - 40 - 1000 - 2050 - 5 - 40 - 1000 - 2050 - 5 - 40 - 1000 - 2050 -Model 40 1000 2050 2400 40 1000 2050 2400 40 1000 2050 24004202AP 4.0 4.5 5.8 6.5 14.0 22.0 22.0 22.0 12.0 15.0 14.0 12.04203AP 7.0 8.0 10.0 11.0 22.0 22.0 20.0 20.0 10.0 12.0 12.0 12.04204AP 8.0 8.5 11.0 11.8 23.0 22.0 22.0 22.0 10.0 12.0 12.0 12.04206AP 11.0 11.5 14.0 16.5 24.0 22.0 22.0 22.0 10.0 14.0 12.0 12.04208AP 12.0 12.5 16.0 18.0 25.0 24.0 22.0 22.0 10.0 12.0 12.0 12.0

PDF created with pdfFactory trial version www.softwarelabs.com

Page 176: Product Catalogue for Operation Spares

31.0 ENTERTAINMENT SYSTEM

Page 177: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1000

Digital Modular Headend Bank

PDM-1000 is a series of Digital Modular Headend, which could be configured by users to be a variety of combination for different by install different modules. These modules has covered professional MPEG-2 SD IRD with IP I/O, professional H.264 HD IRD with IP I/O, H.264 Encoder/Transcoder, MPEG-2 Encoder, Re-Multiplexer and QAM/COFDM Trans-Modulator in a space saving 4Ux19” chassis with 8 slots, and more and more new modules with different features are coming. By these modules, PDM-1000 could meet almost every kind of requirement in the movements from analog to digital TV broadcasting. Each module could be controlled via a portable programmer independently or by HDMS (network Headend Management System) via LAN.

Features DVB-S2/-S/-C/-T reception optional on professional IRD and Transmodulator modules MPEG-2 SD and MPEG-4 AVC/H.264 HD/SD decoding on professional IRD modules QAM or COFDM modulation RF output optional on Transmodulator modules IP output support UDP, RTP Multicast protocol suite Up to 32 Multicast channel output on professional IRD module SNMP based Network Management Highly integrated, supporting 8 modules in 4U*19” chassis Hot-swappable modules Dual power supply with Redundancy unit Easy-to- swappable power supply unit Intelligent cooling system on the basic station Each module work independently Control via network or programmer unit locally Cost-saving by backward compatible with new modules Easily software upgrade via LAN

Page 178: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1000M Basic Station

Providing 8 slots for different PDM-1000 modules in a 4Ux19” chassis, the PDM-1000MF is playing a role of depot ship to supply power, housing and cooling to each PDM-1000 module, no data connection between the PDM-1000MF and PDM-1000 modules. Standard equipped with dual independent power supply units which are hot backup for each other, via which the PDM-1000 could accept two independent power supply system and ensure the headend continue working without disturb in case of one power supply system goes down. With the mounting kit, PDM-1000MF could be easily mounted into wall or rack. Standard 8 slots for modules (could be extended to 9 slots by removing a power supply unit) Standard dual power supply with redundancy unit Easy-to-swappable power supply unit, no need to switch off headend during replacement Intelligent cooling system Wall mount and rack mount available Backward compatible with new modules

PDM-1000CU Programmer Unit PDM-1000CU is a hot-plug ‘keypad + display’ programmer unit and is designed to connect to the PDM-1000 module through a 15-pin D-Sub Connector. This connection provides the powering and signaling paths. Six keys with 2 x 20 characters LCD display let user to perform all necessary accesses to the connected module. 6 keys design and 2 x 20 LCD display. No external power or battery needed. Compatible with future module Connector type: D-Sub, 15pins, Female 170 × 70 x 22 mm, 0.27kg.

PDM-1200P/-1400P Professional MPEG-2 SD IRD Module series

The PDM-1200P/-1400P IRD module could support various optional of reception for DVB-S2/S, or DVB-C, or DVB-T, or TS-over-IP (PDM-1400P), and ASI Input as a standard configuration. Each PDM-1200P/-1400P module has two CI slots for descrambling, and multi-descramble could be achieved by working with a professional CAM module. The descrambled stream could be delivered to the ASI output port, or the built-in re-multiplexer, or the IP Output* port, and meantime one of the inputted services can be decoded by the integrated MPEG-2 SD decoder and output analog CVBS video and stereo audio via a mini 2.5mm phone jack or output digital video via SDI embedded with digital audio. User could take full control and surveillance via Webpage or HDMS (SNMP based network management software) or via the programmer unit locally.

Page 179: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Model List

Input & Process Output Module

Tuner ASI

Input IP Input* CI

Built-in Re-mux

ASI Output

IP Output* Analog

AV

PDM-1200P-S -S

PDM -1200P-S2 -S2

PDM -1200P-T -T

PDM -1200P-C -C

PDM -1400P-S -S 10/100M 6x Multicast

PDM -1400P-S2 -S2 10/100M 6x Multicast

PDM -1400P-T -T 10/100M 6x Multicast

PDM -1400P-C -C 10/100M 6x Multicast

PDM -1400P-44S -S 10/100M 32xMulticast

PDM -1400P-44S2 -S2 10/100M 32xMulticast

PDM -1400P-44T -T 10/100M 32xMulticast

PDM -1400P-44C -C 10/100M 32xMulticast

Note*: the IP interface is half duplex and could be configured to be Input or Output by user.

Technical Specifications Input Interface

DVB-S2 8PSK demodulation Compatible DVB-S, DVB/DSS standard

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F type, Female

Symbol Rates 5~45MBauds for QPSK;10~31MBauds for 8PSK

Roll-off factor 0.35 for QPSK;0.2 for DSS;0.35,0.25,0.2 for

DVB-S2

FEC puncture rate 1/2,2/3,3/4,4/5,5/6,8/9,8/10 for S2 QPSK

2/3,3/4,3/5,5/6,8/9,9/10 for S2 8PSK

1/2,2/3,3/4,5/6,6/7,7/8 for QPSK

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

DVB-S QPSK Demodulation

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F Female

Symbol Rates 2~45MBauds

Roll off factor 0.35

FEC puncture rate 1/2,2/3,3/4,5/6,7/8

Interleave I=12

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

Page 180: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

DVB-C QAM Demodulation

Input frequency range 48~860MHz

Symbol Rates 2~7MS/s

Constellation 64/128/256 QAM,J.83 Annex A or B

Decoding Rates for FEC 1/2,2/3,3/4,5/6,7/8

Input Level -15~15dBmV

Input Interface IEC Female

Input Impedance 75Ω

DVB-T COFDM Demodulation

Input frequency range 174~230MHz(VHF);470~860MHz(UHF)

Input Level -20~-70dBm

Constellation QPSK,16-QAM,64-QAM

Carrier bandwidth 6/7/8 MHz

FTT Mode 2K/8K

Guard Interval 1/4,1/8,1/16,1/32,off

FEC puncture rate 1/2,2/3,3/4,5/6,7/8

Input Interface IEC Female

Input Impedance 75Ω

ASI Input

Connector BNC Connector, 75Ω

Input Bit Rates 100Mbps(Max)

Input Data format Byte

Package Length 188 or 204 Bytes

Common Interface

Type double-deck PCMCIA

Output Interface

ASI Output

Interface BNC Connector, 75Ω

Output Bit Rates 99Mbps(Max)

Output Data format Byte

Package Length 188 or 204 Bytes

Output Signal level 800mVpp±10%

TSoIP Interface (available on 1400P series)

Ethernet Connector RJ45,10/100M

Maximum valid data rate 70Mbps

Protocol UDP/RTP,IGMPv2,ARP

Output Unicast or Multicast

A/V Output

Analog Video Audio output 1x 2.5mm phone jack for CVBS + stereo audio

Digital Video Audio output SDI with digital audio embedded

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP, TCP/IP, HTTP

D-sub 15-pin D-sub connector for programmer unit

Page 181: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1500P Professional H.264 HD/SD IRD Module series

As the latest generation of PDM-1000 professional IRD modules, PDM-1500P series provide a high-level operation experience on H.264 HD video processing to meet the requirement from the Digital broadcasting market that is transferring from MPEG-2 SD to H.264 HD. The integrated decoder complies with MPEG-2 (MP@ ML&MP@HL), MPEG-4 (AVC high profile level 4.1)

standards, and support Dolby® Digital audio decoding to stereo or down-mix and passes through over HD-SDI embedded simultaneously. PDM-1500P support various optional of reception for DVB-T2*

1, DVB-S2/S, or DVB-C, or DVB-T, or TS-over-IP, and ASI Input as a standard

configuration. Each PDM-1500P module has two CI slots for descrambling, and multi-descramble could be achieved by working with a professional CAM module. The descrambled stream could be delivered to the ASI output port, or the built-in re-multiplexer, or the IP Output port. The

decoded video and audio could be outputted via HDMI with Dolby® Digital audio pass-through or

down-mixed PCM audio, or via HD-SDI with Dolby® Digital audio and down-mixed embedded, or via YPbPr component interface, or via CVBS plus stereo audio output. User could take full control and surveillance via Webpage or HDMS (SNMP based network management software) or via the programmer unit locally. Note*

1: DVB-T2 option is coming soon.

Model List

Input & Process Output Module

Tuner ASI

Input IP Input* CI

Built-in Re-mux

ASI Output

IP Output* HDMI HD-SDI

YPbPr CVBS

PDM-1500P-10T2 -T2

PDM -1500P-10S2 -S2

PDM -1500P-10T -T

PDM -1500P-10C -C

PDM -1500P-20T2 -T2 10/100M 6x Multicast

PDM -1500P-20S2 -S2 10/100M 6x Multicast

PDM -1500P-20T -T 10/100M 6x Multicast

PDM -1500P-20C -C 10/100M 6x Multicast

PDM -1500P-30T2 -T2

PDM -1500P-30S2 -S2

PDM -1500P-30T -T

PDM -1500P-30C -C

PDM -1500P-44T2 -T2 10/100M 32xMulticast

PDM -1500P-44S2 -S2 10/100M 32xMulticast

PDM -1500P-44T -T 10/100M 32xMulticast

PDM -1500P-44C -C 10/100M 32xMulticast

Note*: the IP interface is half duplex and could be configured to be Input or Output by user.

Page 182: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications Input Interface

DVB-S2 8PSK demodulation Compatible DVB-S, DVB/DSS standard

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F type, Female

Symbol Rates 5~45MBauds for QPSK;10~31MBauds for 8PSK

Roll-off factor 0.35 for QPSK;0.2 for DSS;0.35,0.25,0.2 for

DVB-S2

FEC puncture rate 1/2,2/3,3/4,4/5,5/6,8/9,8/10 for S2 QPSK

2/3,3/4,3/5,5/6,8/9,9/10 for S2 8PSK

1/2,2/3,3/4,5/6,6/7,7/8 for QPSK

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

DVB-C QAM Demodulation

Input frequency range 48~860MHz

Symbol Rates 2~7MS/s

Constellation 64/128/256 QAM,J.83 Annex A or B

Decoding Rates for FEC 1/2,2/3,3/4,5/6,7/8

Input Level -15~15dBmV

Input Interface IEC Female

Input Impedance 75Ω

DVB-T COFDM Demodulation

Input frequency range 174~230MHz(VHF);470~860MHz(UHF)

Input Level -20~-70dBm

Constellation QPSK,16-QAM,64-QAM

Carrier bandwidth 6/7/8 MHz

FTT Mode 2K/8K

Guard Interval 1/4,1/8,1/16,1/32,off

FEC puncture rate 1/2,2/3,3/4,5/6,7/8

Input Interface IEC Female

Input Impedance 75Ω

ASI Input

Connector BNC Connector, 75Ω

Input Bit Rates 100Mbps(Max)

Input Data format Byte

Package Length 188 or 204 Bytes

Common Interface

Type double-deck PCMCIA

Output Interface

ASI Output

Interface BNC Connector, 75Ω

Output Bit Rates 99Mbps(Max)

Output Data format Byte

Package Length 188 or 204 Bytes

Page 183: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Output level 800mVpp±10%

TSoIP I/O*

Ethernet Connector RJ45,10/100M

Maximum valid data rate 70Mbps

Protocol UDP/RTP,IGMPv2,ARP

Input / Output Unicast or Multicast

A/V Output

Analog Video Audio output 1x 2.5mm phone jack for CVBS + stereo audio, 1x YPbPr

Digital Video Audio output 1x HDMI 1.3, HD-SDI with digital audio embedded*

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP, TCP/IP, HTTP

D-sub 15-pin D-sub connector for programmer unit Note*: the option may not available on different models.

PDM-1300TM Digital Transmodulator Module series

PDM-1300TM series are full-band adjacent agile DVB QAM or COFDM transmodulators, which providing a wide-range of signal reception including DVB-S2/S/T/C over the air or cable. The input signal can be MPEG-2 SD or H.264 HD/SD format. Via the built-in re-multiplexer, users are able to make re-multiplex the transport streams come from tuner and ASI, and make their own customized streams by regenerating and inserting DVB tables, for example NIT, SDT or specify PIDs for their network. And then the customized streams could be delivered to the integrated QAM or COFDM modulator and outputted in RF or outputted via ASI port for further processing or monitoring. User can monitor and configure all parameters on a PC by HDMS via LAN easily. User could take full control and surveillance via HDMS (SNMP based network management software) or via the programmer unit locally. Model List

Input & Process Output Module

Tuner ASI Input Built-in Re-mux

QAM COFDM ASI Output

1300TM-S2C -S2

1300TM-S2T -S2

1300TM-TC -T

1300TM-TT -T

1300TM-CC -C

1300TM-CT -C

1300TM-AC

1300TM-AT

Page 184: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications Input

DVB-S2 8PSK demodulation Compatible DVB-S, DVB/DSS standard

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F type, Female

Symbol Rates 5~45MBauds for QPSK;10~31MBauds for 8PSK

Roll-off factor 0.35 for QPSK;0.2 for DSS;0.35,0.25,0.2 for

DVB-S2

FEC puncture rate 1/2,2/3,3/4,4/5,5/6,8/9,8/10 for S2 QPSK

2/3,3/4,3/5,5/6,8/9,9/10 for S2 8PSK

1/2,2/3,3/4,5/6,6/7,7/8 for QPSK

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

DVB-S QPSK Demodulation

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F Female

Symbol Rates 2~45MBauds

Roll off factor 0.35

FEC puncture rate 1/2,2/3,3/4,5/6,7/8

Interleave I=12

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

DVB-C QAM Demodulation

Input frequency range 48~860MHz

Symbol Rates 2~7MS/s

Constellation 64/128/256 QAM,J.83 Annex A or B

Decoding Rates for FEC 1/2,2/3,3/4,5/6,7/8

Input Level -15~15dBmV

Input Interface IEC Female

Input Impedance 75Ω

DVB-T COFDM Demodulation

Input frequency range 174~230MHz(VHF);470~860MHz(UHF)

Input Level -20~-70dBm

Constellation QPSK,16-QAM,64-QAM

Carrier bandwidth 6/7/8 MHz

FTT Mode 2K/8K

Guard Interval 1/4,1/8,1/16,1/32,off

FEC puncture rate 1/2,2/3,3/4,5/6,7/8

Input Interface IEC Female

Input Impedance 75Ω

Page 185: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

ASI Input

Connector BNC Connector, 75Ω

Input Bit Rates 100Mbps(Max)

Input Data format Byte

Package Length 188 or 204 Bytes

Output

QAM Modulation

Constellation J.83 Annex A:16/32/64/128/256QAM;

J.83 Annex B:64/256QAM

Symbol Rate 3~7.2MBauds

I/Q Amplitude Error < 0.3%

I/Q Phase Error < 0.3°

Phase jitter < 0.5°RMS

MER > 35dB

Output freq. range 48~860MHz agile, step by 10KHz

Output level 97 to 110dBµV,step by 1dB

Spurious Rejection > 55dBc

Output Interface 75Ω,F type female

Output return loss > 12dB

COFDM modulation

Constellation QPSK/16QAM/64QAM

FFT mode 2K

Guard Interval 1/4,1/8,1/16,1/32,off

Output freq. range 48~860MHz agile, step by 10KHz

Output level 97~110dB V ,step by 1dB

Spurious Rejection > 55dB

Output Interface 75Ω,F type female

Output return loss > 12dB

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP

D-sub 15-pin D-sub connector for programmer unit

Page 186: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1300MX Re-multiplexer Module PDM-1300MX is an 8 ASI inputs DVB re-multiplexer with redundancy ASI outputs. With the powerful DVB table regenerator supported by HDMS, DMM-1300MX provides users a very flexible and user-friendly interface to customize the input TS and regenerate a new output TS. User could take full control and surveillance via programmer unit locally or via HDMS (SNMP based network management software) over LAN network.

Technical Specifications

ASI Input

Input Interface 8* BNC Connectors,75Ω

Maximum Input data rate 160Mbps

Data transfer clocking BYTE or BURST mode auto-detective

Packet Length 188 /204 bytes, auto-detective

ASI Output

Output Interface 2* BNC,75Ω

Maximum data rate 99Mbps

Data transfer clocking Byte

Packet Length 188 or 204 Bytes

Signal Level 800mVpp±10%

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP

D-sub 15-pin D-sub connector for programmer unit

Page 187: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1300EC Professional MPEG-2 SD Encoder Module

PDM-1300EC is a real time MPEG-2 SD Encoder, could support analog CVBS and stereo audio input or digital video input with audio embedded via SDI interface. User could specify service name, service ID, Video PID, Audio PID, and TSID for the new encoded stream. And the GOP, Encoding bit rate, 4:3/16:9 picture aspect ratio, and other picture parameters such as luminance and contrast could be also easily configured by user. User could take full control and surveillance via HDMS (SNMP based network management software) or via the programmer unit locally.

Technical Specifications

Encoding

video input format NTSC,PAL or SECAM, 4:3/16:9 aspect ratio selectable

Video compression MPEG-2 MP@ML

Audio compression MPEG1 Layer1,Layer2

Video output Bit rate 1.5~15Mbps

Audio Sample rate 32,44.1,48 KHz

Audio output Bit rate 32,64,128,192,256,384 Kbps

Input Interface

A/V Input

Audio Interface RCA female,Stereo L/ R

CVBS Video Interface RCA female,75Ω

SDI Video Interface BNC female,75Ω

SDI embed audio Stereo or Dual sound, group 1 to 4 selectable

Output interface

ASI Output

ASI output Interface BNC Female,75Ω

Effective data rate Byte

Packet Length 188 / 204 Bytes

Signal Level 800mVpp±10%

Return loss > 15dB

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP

D-sub 15-pin D-sub connector for programmer unit

Page 188: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDM-1500EC Professional H.264 HD/SD Encoder/Transcoder and

Re-Multiplexer Module

Integrated with H.264 HD/SD Encoder, MPEG-2 to H.264 Transcoder and DVB-TS re-multiplexer, PDM-1500EC provide users a high-level operation experience to meet the requirement from the Digital broadcasting market that is transferring from MPEG-2 SD to H.264 HD. PDM-1500EC could support various analog or digital video audio inputs via CVBS, YpbPr, HD-SDI with embedded audio for encoding, and TSoIP, ASI input for transcoding. PDM-1500EC could support one pair of analog stereo audio encoding, and Dolby® Digital audio can be looped through and re-inserted into the transcoded H.264 stream when transcoding. User can create their own services by specifying the service name, service ID, Video PID, Audio PID, and TSID etc. Via the built-in re-multiplexer, the new generated H.264 stream could be re-multiplexed with other transport streams inputted from ASI or IP Input* and then delivered to ASI output or IP Output* port. User could take full control and surveillance via HDMS (SNMP based network management software) or via the programmer unit locally. Note*: the IP interface is half duplex and could be configured to be Input or Output by user.

Technical Specifications

Video input and compression

HD-SDI BNC Connector

YPbPr 2.5mm phone jack port

CVBS 2.5mm phone jack port

Compression format H.264, High Profile Level 4.0

Video Encoding bit rate 2Mbps-20Mbps

Audio input and compression

Input HD-SDI embedded, Analog audio (2.5mm phone jack port)

Compression format MPEG1 Layer II(MPEG-2AAC,AC-3 selectable)

Sampling rate 48KHz

Audio compression bit rate 16~256Kbps

ASI Input

Interface BNC Connector, 75Ω

Maximum Data rate 170Mb/s

Data format Byte

Packet Length 188/204 Bytes

Signal Level 800mV

ASI Output

Interface 75Ω,BNC port

Data transfer rate 170Mb/s

Data format Byte

Packet Length 188/204 Bytes

Signal Level 800mV

Bit Rate 1.5~67Mbps adjustable

TS over IP I/O

Ethernet Connector RJ45,10/100M

Maximum valid data rate 70Mbps

Protocol UDP/RTP,IGMPv2,ARP

Input / Output Unicast or Multicast

Page 189: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP

D-sub 15-pin D-sub connector for programmer unit

Page 190: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-3000P

Professional Digital IRD

PDH-3000P-S/C/T series are high performance-to-price ratio IRDs. User can insert up to two PCMCIA CA modules to decrypt various conditional access systems, such as Conax, CryptoWorks, Irdeto, NDS and Viaccess etc. Easy to use, low maintain cost and flexible factory optional make the PDH-3000P the best choice for CATV digital headend system.

Features Factory optional for DVB-S/C/T reception

MPEG-2(MP@ML)decoding

Up to 2 Common Interface slots (PCMCIA) can support various CAM modules

ASI Input (optional)

TS loop through output for further decrypting

CVBS video and balanced stereo audio XRL output

Transparent decrypted or non-decryption switch

Auto network or transponder search function and dynamic update following

stream changing

Support OSD, Teletext (DVB ETS 300 706) and Subtitile display

EPG function, support PIG (Picture in Graphics) display

256 color OSD, support various languages

Software upgrade via RS-232 interface

Automatic last channel memory

Page 191: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications QPSK Demodulation((((Comply with DVB-S、、、、MPEG2、、、、ETSI 300421 standard))))

Input frequency range 950~2150MHz

Input level -25~-65dBm

Input impedance 75Ω F-type female

Symbol rate 2~45MBauds(SCPC or MCPC)

Rolling off factor 0.20 or 0.35

Punctured rates 1/2,2/3,3/4,5/6,6/7,7/8

Reed-Solomon decode 204,188,T=8 & I=12

DVB-C QAM Demodulation

Input symbol rate range 1~7MS/s(PAL),1~6MS/s(NTSC)

Demodulation 16/32/64/128/256QAM

Bandwidth 6MHz/7MHz/8MHz

FEC code rate 1/2,2/3,3/4,5/6,7/8;K=7

Input frequency range 48~860MHz

Input level -15~15dBmV

Input impedance 75Ω,IEC

DVB-T COFDM Demodulation((((comply with DVB-T&MPEG2 standard))))

Input code rate 4.98~31.67Mbps(8MHz bandwidth)

Constellation QPSK,16-QAM,64-QAM

Tuner bandwidth 8MHz

FFT mode 2K/8K

Guard interval 1/4,1/8,1/16,1/32,off

FEC code rate 1/2,2/3,3/4,5/6,7/8

Input frequency 470~862MHz, 174~230MHz

Input level -20~-70dBmV

Input impedance 75Ω,F-type

DS3 Input

Input impedance 75Ω

Connector BNC

Max. input rate 44.736Mbit/s

Format Unframed or framed Framing according to G.804/G.752

(DS3)

DS3 Loop through

Impedance 75Ω

Max. output code rate 44.736Mbit/s

Connector BNC

Format Unframed or framed Framing according to G.804/G.752

(DS3)

Front Panel

Digital LED display 4×LED to display current channel number

CI PCMCIA module slots 2×JEIDA 4.0 PCMCIA type II type,suppoert various CAS

Control button 8 buttons for full operation

LED 3×LED for simple status monitoring

Page 192: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Rear Panel

Tuner input and output Signal input and loop through output

Power supply AC 90~240V,50/60Hz

RS-232 for software update

ASI 1×input(optional)

2×output (optional)

XRL output 2×XRL

CVBS output 1×BNC

RCA output 1×RCA

General Operating temperature 0~45

Storage temperature -20~70

Dimension 44mm×483mm×240mm Weight 3Kg

Model List Function PDH-3000P-DS3 PDH-3000P-30x PDH-3000P-20x PDH-3000P-18x PDH-3000P-10x

-30S -30C -30T -20S -20C -20T -18S -18C -18T -10S -10C -10T

DS3 input/loop DVB-S input DVB-C input DVB-T input

PCMCIA slot(×2)

ASI input ASI output CVBS output RCA output XRL output *Simulcrypt Compliant ASI cascade connection Last channel memory Support NTSC/PAL/AUTO RS-232 *Multiple Decryption CAM is needed.

Page 193: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-3000EC-30/40

Professional Standard Definition MPEG-2 Encoder and Multiplexer

PDH-3000EC is a single program MPEG-2 real-time encoder with an internal re-

multiplexer which accepts the SPTS generated by itself and an external DVB-ASI TS as inputs. This flexible arrangement saves the costly external re-MUX and could be

adopted by many applications with its high quality, stable video and audio compression. The re-multiplexed TS output is available as ASI output and Streaming IP (option). User

can take full control and management via front panel or HDMS the network management software on PC.

Model

PDH-3000EC-30

PDH-3000EC-40 (IP streaming output)

Features

* S-Video, SDI and Composite PAL/NTSC/Secam video input

* Balance audio input * MPEG-2 MP@ML compliant

* Video encoding 1.5Mbps-10Mbps

* MPEG-1 Layer1 and Layer2 audio encoding * Configurable GOP

* Internal two-way Re-Multiplexer

* Support PAT, PMT and SDT generation * Support NIT insertion

* SNMP based remote control system

* SDI input embedded digital audio * LCD display and user friendly operation menu

* Supports up to 6 multicast IP streams (option 40)

Page 194: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications

Video input and compression

Input Composite video,S-Video,SDI(embedded audio)

Video format PAL, NTSC, SECAM

Compression format MPEG-2 MP@ML(ISO/IEC13818-2)

Video encoding Bit rate 1.5Mbps-10Mbps

Resolution Full D1,Half D1,SIF,QSIF

Audio input and compression

Input interface 600Ω, balance XRL female

SDI embedded audio One pair stereo or dual sound, Group 1 to 4 selectable

Compression format MPEG1 Layer I, II

Signal sampling rate 32K,44.1K,48K

Compression bitrate 32,64,128,192,256,384Kbps

MPEG-2 TS Re-multiplexer

ASI Input

Connector BNC connector, 75Ω

Input data rate 100Mb/s

Data mode Byte mode

Packet length 188/204 Bytes

Signal level 800mV

TS input SPTS/MPTS

ASI Output

Connector BNC connector, 75Ω

Output data rate 100Mb/s

Data mode Byte mode

Packet length 188/204 Bytes

Signal level 800mV

Output Bit rate 1.5Mbps~67Mbps adjustable

PSI/SI Auto/manual Automatic PAT,PMT,SDT generation,SI insertion

IP output

Interface RJ45, 10/100M

Maximum output bit rate 70Mbit/S

Transport protocol UDP/RTP, up to 6 multicast /unicast

Multicast output protocol IGMPv2

Rear panel

CVBS In 1× BNC connector

XLR In 2× XLR balanced

S-Video In 1× S-video connector

SDI In 1× BNC connector

ASI I/O 1×input;2×output

Power supply AC 90~260V,50~60Hz

RS-232 D-Sub 9-pin interface

Page 195: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Ethernet RJ45, 10M/100M, for management and software upgrade

TS/IP(optional for -40) 10/100Mbps

General

Operating Temperature 0~45

Storage Temperature -20~70

Humidity <85%

Dimensions 44mm×483mm×240mm

Net weight 3Kg

Function PDH-3000EC-10 PDH-3000EC-30 PDH-3000EC-40 PDH-3000EC-41

AV/S video

ASI input

SDI input

Re-mux

IP Output

ASI input

Network control

Standard function

Page 196: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-3000EC-41

Quad Standard Definition MPEG-2 Encoder

PDH-3000EC integrated four SD MPEG-2 Encoders into one unit, which is

able to compress and encode 4x CVBS videos with 4x pairs of stereo audios

into 4x MPEG-2 SPTS, and then remux the 4x SPTS into one MPTS via the

built-in re-multiplexer with editable PSI/SI generator. User can take full

control and management easily via front panel or via network management

software on PC.

Features

MPEG-2(MP@ML)(ISO/IEC14496-2)and MPEG-1(ISO/IEC11172-2)

standards compliant

4:3/16:9 image aspect ratio configurable

High quality audio pre-processing technology, unbalance stereo input

2x ASI redundant outputs

CBR/VBR encoding mode configurable

PID display and setting,support SDT, NIT editing and insertion

Adopts 10-bit ITU-R BT.656 video encoding and PCM audio encoding

Local configuration or remote control via network management software

Page 197: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Video input and compression

Input composite video,power level 1.0Vp-p

Video format PAL, NTSC

Compression MPEG-2 MP@ML(4:2:0), follow ISO/IEC 14496-2

standard,

Video encoding Bit rate 1.5Mbps-15Mbps

Resolution PAL:720×576

NTSC:720×480

Audio input and compression

Compression format MPEG-1 Layer I, II

Sampling rate 32K,44.1K,48K

Compression bit rate 128, 256, 384Kbps

Output

DVB-ASI x 2

Connector BNC connector, 75Ω

Packet length 188/204 Bytes

Signal level 800mV

Output bit rate 1.5Mbps-99Mbps adjustable(minimum step 1Kbps)

PSI/SI Editable by network management software

Front panel

LCD display 2×20 characters LCD display

Button up,down,left,right,enter,menu,lock

LED 1x power indicator; 1x alarm indicator

Rear panel

AV input(RCA) 4× CVBS

4× Stereo (L/R)

Power supply AC 90~240V,50~60Hz,25W

ENTHERNET 10/100Mbps

Others

Operating Temperature 0~45

Storage Temperature -20~70

Humidity < 85%

Dimensions 44mm×483mm×330mm

Net weight 3.6Kg

Page 198: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-4000P

Professional Digital TV Processor

PDH-4000P series is the most successful PBI’s professional IRD receiver so far. With a variety of reception options including ASI, TSoIP*, DVB-S2/S, DVB-C, DVB-T, DS3, and flexible output (CVBS, SDI, ASI, DS3 and IP) combinations, PDH-4000P could be deployed in many applications, such as digital TV signal reception and processing, distribution and so on. PDH-4000P has two CI slots for descrambling, and multi-descramble could be achieved by working with a professional CAM module. The descrambled stream could be delivered to the ASI output port, or the built-in re-multiplexer, or the IP Output* port, and meantime one of the inputted services can be decoded by the integrated MPEG-2 SD decoder and output analog CVBS video and stereo audio or digital video via SDI embedded with digital audio. User could take full control and surveillance via Webpage or HDMS (SNMP based network management software) or via front panel locally. Since the day launched in the market, PDH-4000P has won the praise from the customers with its stability and excellent performance. Note*: the IP interface is half duplex and could be configured to be Input or Output by user.

Features

MPEG-2, MP@ ML decoding

DVB-S2/S /-T/-C reception options

10/100M TSoIP Interface, upgradeable to GbE IP* (optional)

UDP/RTP protocol suite compliant

Multicast and Unicast support on IP interface (optional)

Two CI slots, supports various Conditional Access systems

Webpage, HDMS, and Front panel operation

SDI video output with digital audio embedded

Two groups of ASI outputs, can output different TS from different signal sources.

Dynamic PMT changing detection and automatic update output correspondingly

DS3 I/O for TS (optional)

Teletext VBI, EBU subtitle and DVB subtitle

Upgradable through LAN

Note*: the GbE IP board is coming soon.

Page 199: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications Tuner

DVB-S2 8PSK Demodulation (Compatible DVB-S, DVB/DSS standard)

Input frequency range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Input Interface F type, Female

Symbol Rates 5~45MBauds for QPSK;10~31MBauds for 8PSK

Roll-off factor 0.35 for QPSK;0.2 for DSS;0.35,0.25,0.2 for DVB-S2

FEC puncture rate 1/2,2/3,3/4,4/5,5/6,8/9,8/10 for S2 QPSK

2/3,3/4,3/5,5/6,8/9,9/10 for S2 8PSK

1/2,2/3,3/4,5/6,6/7,7/8 for QPSK

LNB power supply 0,13V,18V optional

0/22K Switch 0/22KHz optional

QPSK Demodulation (DVB-S, ETSI 300421 standard compliant)

Input frequency range 950~2150MHz

Input level -25~-65dBm

Input impedance 75Ω,F-type female

Symbol rate 2~45MBauds(SCPC or MCPC)

Rolling off factor 0.20 or 0.35

Punctured rates 1/2,2/3,3/4,5/6,6/7,7/8

Reed-Solomon decoding 204,188,T=8 & I=12

DVB-C QAM Demodulation

Input symbol rate range 1~7MS/s

Demodulation 16/32/64/128/256

Bandwidth 6/7/8MHz

FEC decode 1/2,2/3,3/4,5/6,7/8

Input frequency 50~860MHz

Input level -15~15dBmV

Input impedance 75Ω,IEC Female

DVB-T COFDM Demodulation

Demodulation QPSK,16-QAM,64-QAM

Bandwidth 6MHz/7MHz/8MHz

Guard interval 1/4,1/8,1/16,1/32,off

FFT mode 2K/8K

FEC code rate 1/2,2/3,3/4,5/6,7/8

Input level -20~-70dBm

Input frequency 174-230MHz(VHF),470-862MHz(UHF)

Input impedance 75Ω

DS3 I/O

Input impedance 75Ω

Max. input bit rate 44.736Mbit/s

Format Unframed or framed Framing according to G.804/G.752(DS3)

Connector BNC

Page 200: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

TS over IP I/O

Ethernet Connector RJ45, 10/100M

Max. bit rate 70Mbits/s

Protocol UDP/RTP; support unicast or multicast

Management protocol IGMPv2

ASI Input

Connector BNC Connector, 75Ω

Input Bit Rates 100Mbps(Max)

Input Data format Byte

Package Length 188 or 204 Bytes

Common Interface

Type double-deck PCMCIA

Output Interface

ASI Output

Interface BNC Connector, 75Ω

Output Bit Rates 99Mbps(Max)

Output Data format Byte

Package Length 188 or 204 Bytes

Output Signal level 800mVpp±10%

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP, TCP/IP, HTTP

Front panel control LCD display and keypad

Page 201: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-5000P

Multi-Format professional HDTV Processor

Note*

1: DVB-T2 option is coming soon.

Features

Factory optional for DVB-T2, DVB-S2/S, DVB-C, DVB-T reception

MPEG-2(MP@ ML& MP@HL)and MPEG 4 Part 10 (AVC high profile level 4.1) standards compliant

and decoding

Wide choice of I/O interfaces, including ASI input/output, CVBS output, YPbPr output, HDMI output,

SD/HD-SDI output (embedded 2 pairs stereos audio), AES/EBU output, 10/100M or 100/1000M TS over IP

input/output (optional), DS3 interface (optional)

DS3 in/out interface is compatible with Barco, Huawei protocols

Built-in re-multiplexer

BISS 1 or BISS E decryption

Dynamic PMT detection and automatic update

VBI TELETEXT, EBU/ DVB SUBTITLE support

WSS support

Closed caption support

10/100M Ethernet TSoIP I/O, compatible for future Gigabit Ethernet daughter board

UDP and RTP for TS over IP I/O

DVB and IPTV mode IP output

Unicast and Multicast support

Control and surveillance over WEB or HDMS software remotely

Selectable 2x PCM (Down-mixed AC3) audio output over HDMI or AES-EBU or SDI embedded

AC3 audio pass-through over HDMI or AES-EBU or SDI embedded (SDI support 2x AC3 audio

embedded)

Two DVB-CI slots, support multiple programs decryption

Page 202: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Technical Specifications

DVB-S2 Demodulation

Input Frequency Range 950~2150MHz

Input Level -25~-65dBm

Input Impedance 75Ω

Connector F-type female

Symbol rate 2~45MBauds for QPSK

2~45MBauds for 8PSK

Rolling off factor 0.35 for QPSK

0.35,0.25,0.2 for DVB-S2

Punctured rates DVB-S QPSK:1/2,3/5,2/3,3/4,4/5,5/6,8/9,8/10

DVB-S2 8PSK:3/5,2/3,3/4,5/6,8/9,9/10

LNB Level 0,13V,18V adjustable

0/22K 0/22KHz selectable

DiSEqC DiSEqC 1.0

DVB-C QAM Demodulation

Tuner input symbol rate 1~7MS/s(PAL),1~6MS/s(NTSC)

Demodulation 16/32/64/128/256QAM

Bandwidth 6MHz or 7MH or 8MHz

Input frequency 48~860MHz

Input level -15~15dBmV

Input impedance 75Ω,IEC female

DVB-T COFDM Demodulation

Demodulation QPSK,16-QAM,64-QAM

Bandwidth 6MHz/7MHz/8MHz

FFT mode 2K/8K

Guard interval 1/4,1/8,1/16,1/32,off

FEC code rate 1/2,2/3,3/4,5/6,7/8

Input frequency 174-230MHz(VHF),

470-862MHz(UHF)、

Input level -20~-70dBm

Input impedance 75Ω,IEC female

TS over IP I/O

Ethernet Connector RJ45, 10/100M

Max. bit rate 70Mbits/s

Protocol UDP/RTP,

Support Multicast or Unicast

Multicast control protocol IGMPv2

Other I/O Interface

Common Interface

Type double-deck PCMCIA

Input interface

Page 203: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Tuner IN 1×input, 1×loop through output

ASI OUT 2× BNC Female,75Ω

Output interface

ASI OUT 2×2 BNC Female,75Ω

SDI OUT 2×BNC Female,75Ω; supports HD-SDI/SD-SDI,(one for back-up)optional

HDMI 1x HDMI 1.3 interface

YPbPr 1

CVBS 1×RCA,1xBNC

AES/EBU 2×9-pins D-sub connector,AES/EBU and XRL audio output ports

Serial Port 1×RS-232 9-pin D-sub

Ethernet Connector 1×RJ45, 10/100M, for network management

1×RJ45, 10/100M, for TS over IP (optional)

Output Video format

SDI 1080ix60, 1080ix50, 576ix50, 480ix60

HDMI 1080ix60, 1080ix50, 1280x720px60, 1280x720px50,

720x480p60,720x576p50,576ix50,480ix60

YPbPr 1080ix60, 1080ix50, 1280x720px60, 1280x720px50

720x480p60, 720x576p50, 576ix50, 480ix60

CVBS port 576ix50, 480ix60

Management

Ethernet Connector RJ45,10/100M, for NMS and software upgrade

Protocol SNMP, TCP/IP, HTTP

Front panel control LCD display and keypad

General

Dimensions 44mm×483mm×255mm

Weight 5Kg

Power supply AC90V~260V,50/60Hz,30W

Operating temperature 0~45

Humidity <95%

Page 204: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

PDH-5000EC

DVB (H.264) Encode & TranscoderDVB

PDH-5000EC is the latest successive version of H.264/AVC Encoder plus

the MPEG-2 to H.264/AVC Transcoder. Integrated with the TSoIP board,

the 5000EC accepts TS over IP or ASI input for transcoding, or alternatively

accepts HD-SDI, HDMI or YPbPr input for encoding, the final output is

available in IP or ASI format. With extraordinary picture quality and

significant bandwidth liberation, PDH-5000EC is the best choice for higher

performance encoding and migration from MPEG-2 to H.264.

Features

* H.264/AVC (MPEG-4 part 10), High profile, Level 4.0, 4:2:0

Chrominance sampling

* TS to TS Transcoding MPEG-2 HD to H.264 HD/SD, or MPEG-2 SD to H.264 SD

* MPEG-1 Audio Layer1 & Layer2 encoding

* 1x Dolby Digital (AC-3) or 1x MPEG-1 audio pass through transcoding * Supports full HD 1080i encoding

* Extensive video pre-processing solutions * Best possible picture quality from 2.0 Mbit/s to 20 Mbit/s * 1x Stereo pair analogue XRL Balance audio input, or digital AES/EBU audio input

option * HD-SDI, HDMI, YPbPr/RGB video input interface

* Full-Duplex TS over IP I/O, RTP protocol ready for Unicast and Multicast (does not

require external encoder) * ASI input and output

* SNMP Ethernet Management

Page 205: Product Catalogue for Operation Spares

SKYCOM SATELLITE SYSTEMS PTE LTD

68 Kallang Pudding Road #07-01 SYH Logistics Building, Singapore 349327

Tel: (65) 67494111 Fax: (65) 67428030

Website: http://www.skycomsatellite.com

DIGITAL HEADEND SYSTEM

Specifications Video Input and Compression Video input interface HD-SDI, HDMI, YPbPr, RGB

Video Compression H.264 High Profile / Level 4.0 Half-Duplex Codec Bit rate 20Mbps (max.)

Frame rate 1fps-25/30fps Resolution 1920×1080×60i/50i, 1440×1080×60i/50i,

1280×720×60p/50p, 720×480×60i, 720×576×50i

Audio Input and Compression Audio input Interface Stereo RCA female, 600 ohm

MPEG-1 Audio Layer 1&Layer2 encoding Audio Compression Format

Dolby Digital(AC-3) pass-through TS I/O

ASI Input BNC×1, 75ohm MPEG over IP 10/100Mbps T-base, RJ45, RTP over UDP/TCP, Unicast or Multicast ASI output BNC×1, 75ohm

Operation Environment Operating Temperature 0~45

Humility < 85%, Non-condensed Power supply AC 90~260V 50Hz/60Hz 15W Dimensions 240mm×440mm×44mm

Net weight 3Kg Storage Temperature -20~70

Page 206: Product Catalogue for Operation Spares

32.0 DTRS SYSTEM

Page 207: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

130/137

11.4 COM card

INDICATORS:

Green indicator: Power present

Yellow ACT indicator: Flashing card active

Yellow RX indicator: On physical layer active on

both sides of the link:

Synchronisation OK

Green B1 indicator: On during communications

channel B1 occupied

Green B2 indicator: On during communications

channel B2 occupied

Description:

The COMS card gives the possibility of having a S0

or T0 type phone connection.

This type of link carries 1 signal channel (D) and 2

phone channels 'B).

This card is therefore adapted to a small network

wishing to limit resources dedicated to phone

communications (max. 2) and the cost of the access

to the phone network.

The T0 or S0 access is processed in compliance with

the VN4 and VN5 specifications of the EURO-RNIS

network

Page 208: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

131/137

11.5 COM3 card

INDICATORS:

Green indicator:5V present

Yellow ACT indicator: slow flashing

*Cyclic ON/OFF ratio: 50% Card operating in direction A of a ring network

*Cyclic ON/OFF ratio: 25%

Card operating in direction B of a ring network

Yellow RXA indicator: On. If link (G703, V11) connected in direction A of a ring or

star network

Red ERRA indicator: Always off

Yellow RXB indicator: on. If link (G703, V11) connected in direction B of a ring or

star network

Red ERRB indicator: Always off

Description:

Management of the G703/V11 link between two sets

The 'act' indicator located on the front face:

Does not light if a local problem is detected on the card.

Flashes at about 3 Hz if the card is operational but is not controlled by the CPU

card.

Flashes at about 1 Hz if the card is operating under the control of the CPU card.

G703 Use:

The card permanently transmits on the two G703 junctions; The signals received on

these junctions are analysed and the indicators on the front face show the state of these

junctions:

'ERR’ indicator: red indicator lighting when a line error is detected on the

junction or if there is no 2Mb/s signal (disconnection for example).

Yellow 'Rx’ indicator: flashes when a G704 synchronisation is detected; stays

on when a synchronisation is detected and the link with the switch is

established.

Page 209: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

132/137

11.6 DCTR card

INDICATORS:

ALIM indicator: 5V present

Yellow ACT indicator: One second flashes

Yellow MFR indicator: On (CTR3)

Red rouges D1, D2 , D3 indicators: Off if BS inactive

Fast flashes during communication

D1, D2: received field level

D3: decoding of received radio frames

PLL indicators: indicates that both PLLs are in slave

mode

Page 210: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

133/137

11.7 SUPIP card

INDICATORS:

Green indicator: Power present

Yellow ACT indicator: slow flashing

Red INT indicator: fast flashing (PC interruption)

Description

This card is unique in a switch, it is similar to a CPU card. Its

role is to ensure the mixing of the phone channels and the

interfacing of IP dispatching.

Only the connection port to a local network is used; it only

conveys voice over IP traffic for dispatching.

Page 211: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

134/137

11.8 UCM card

INDICATORS:

1 Red led indicating power supply

2 Yellow led (EF/) indicating arrival of

3 Yellow led (ALC) indicating that power regulation is active

and corresponds to the set point. If this led flashes it indicates that

it is at the limit of losing slave mode In this state, the status

transmitted to the CPU card is ALC off.

4 Yellow led (COR) indicating that linearity regulation is active

5 Yellow led (PLL) indicates that both PLLs are in slave mode

6 Red led (CTX) indicates that transmission power is activated

Test button:

6 The continuous activation of this button produces a

Tetra modulation composed only of '1's. The result is a

carrier at frequency F0 + 2.25 kHz.

7 Pushing and releasing this button 3 times in a row

resets the card. The microcontroller and the Xilinx are

reset.

Page 212: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

135/137

11.9 UCM2 card

INDICATORS:

1. Green led indicating power supply

2. 28V Led indicating that the PA is supplied

3. Red led (CTX) indicates that transmission power is

activated

4. Yellow led (PLL) indicates that both PLLs are in slave

mode

5. Yellow led (IO) indicating that the card is receiving data

from the CPUBDT card

6. Yellow led (ALC) indicating that power regulation is active

and corresponds to the set point. If this led flashes it

indicates that it is at the limit of losing slave mode In this

state, the status transmitted to the CPU card is ALC off .

7. yellow LINE led corresponding to signal linearity correction

of the broadcast signal

8. Red LOWP led indicates the presence of the low power

alarm (sent by the PA)

a. No problem if off

9. Red VSWR led indicates presence of TOS alarm (sent by

the PA) Adaptation of antenna output Not a problem if off

10. Red Temp led indicates the presence of the temperature

alarm (sent by the PA)

a. PA Temperature

b. No problem if off

Test button:

The continuous activation of this button produces a Tetra

modulation composed only of '1's. The result is a carrier at

frequency F0 + 2.25 KHz.

Pushing and releasing this button 3 times in a row resets the card.

The microcontroller and the Xilinx are reset.

Page 213: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

136/137

11.10 Power amplifier (PA)

This module amplifiers the RF signals sent by the CPU module in order to deliver 10 Watts RF.

It is powered by +28 volts and can be checked on the front face of the UCM2. The PA alarms

are present on the front face of the UCM2. The PA provides a set point for the regulation of its

output power.

The amplifier has an internal blocking mechanism if it does not receive the transmission

command from the UCM. No measurements can be made if the BS is not in TETRA

transmission.

The module has an integrated circulator which protects it from accidental load disconnections

and considerably minimises the risks of intermodulation with neighbouring transmitters.

The power amplifier is mounted on the rear face of the BS.

Page 214: Product Catalogue for Operation Spares

NeTIS Maintenance assistance guide – Version1.0

137/137

RF Amplifier

output

PA power supply

RF input

Ventilator

power supply

* Tx PA commands

* Power regulation

* PA alarms

Ventilator power by

+12V Radiator