prex issues

22
PREX Issues

Upload: fausta

Post on 06-Jan-2016

41 views

Category:

Documents


1 download

DESCRIPTION

PREX Issues. Outline. New issue: souce systematics and Aug. 07 run. Update on old issues. Progress at SU. Running With Other Halls. Helicity-correlations with beam position much worse with high current operation in other halls. Possible causes: Cathode (Hall B and C). - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PREX Issues

PREX Issues

Page 2: PREX Issues

Outline

• New issue: souce systematics and Aug. 07 run.

• Update on old issues.

• Progress at SU

Page 3: PREX Issues

Running With Other Halls

• Helicity-correlations with beam position much worse with high current operation in other halls.

• Possible causes:– Cathode (Hall B and C).– Cross-talk in the linac (Hall C only)

• Depends on Laser set-up.• Need realistic test to dermine of PREX

must run alone

Page 4: PREX Issues

10 Day test run in Aug07

• Study cross-talk issues.

• Compton tests (Integration)

• Noise test with LUMI, 18 bet ADC’s, etc.

• Detector (Use Moller spectrometer as test beam.

Page 5: PREX Issues

Compton-Biggest Issue

• New Hardware– Green laser– New photon and electron detectors

• Data analysis– Rewrite code in C++ style– Understand systematics

• Integration and Low energy– Achieve good systematics (<1) with

integration.

Page 6: PREX Issues

Recent Compton Progress

• See later talks

• Observed Compton peak with FADC.

• Work at SU (see below).

Page 7: PREX Issues

Integration test with IR light

• Need to take extended Compton data with electron analysis, conventional photon analysis, and integrated Compton analysis and ahcieve agreement better than 1%.

Page 8: PREX Issues

Plan for 850 MeV Compton

• Assume that some of the time the electron analysis will work: need to get near enough beam to get half of spectrum

• Demonstrate linearity of photon detector response with coincidence data.

• Compute linearity with MC-effect of GDR neutron production?

• Show that integral and electron agree on good days.

Page 9: PREX Issues

Warm Septum

• Plan A– NSF MRI: Request submitted to SU, approved

at Smith (Smith and SU will build the magnets).

• Plan B– Build at JLab if proposal not funded.

Open issue: Can the new magnet use the oldVacuum system?? Other issues? NeedsFocus at JLab.

Page 10: PREX Issues

Need 100 ppm pair noise

• 18 bit ADC’s have arrived.

• Can/should we use Qweak electroncs?

• Do we have difficult ground-loop problems?

• What is our pedestal noise with the new setup?

• Critical test: <100 ppm noise with LUMI.

Page 11: PREX Issues

Target

• This spring, a 1/3 thickness Pb target with diamond cooling will be used in a Hall A experiment.

• This will test radiation damage of diamond cooling, radiation, etc.

• Is this a good opportunity for a LUMI test?

• Check cavity-stripline agreement?

Page 12: PREX Issues

Detector

• Only option: thin quartz. Same as Qweak.

• Need to show narrow response to single electrons: earlier test failed.

• Quartz PMT? More light, less neutrons.

Page 13: PREX Issues

Other Issues (see memo)

• High Field Moller (Compton Cross-check) –Eugene

• Detector Linearity

• Pole-tip Monte Carlo

• Management of large transverse beam asymmetry

• Angle measurement

• Low current running issues

Page 14: PREX Issues

Compton analysis at SU

• Fix bugs

• Understand goofy runs

• Study line-shape systematics

Page 15: PREX Issues

Fits to spectra look good

Tails now under control

Page 16: PREX Issues

Difference between polyand dual exponential

Spike shows up whereDual exponentialHas discontinuity in2nd derivative

Page 17: PREX Issues

Noise in FADC

• To integrate, we must add 6x106 samples without adding too much noise.

• Following data looks promising, but issue is not trivial.

• Is there more noise running in the hall?

Page 18: PREX Issues

Bin half of one window

Pedestal noiseIs not statistical.The χ2 getsWorse the longer The window

Page 19: PREX Issues

Fanout adds noise

Page 20: PREX Issues

Cavity Monitors: Work in Progress

• Show great promise: Resolution at least as good as stripline. (Redundancy).

• Gossip: G0 had excellent performance;10 ppm pulse pair width??

• Problems isolated– Cross talk– Oscillation

Page 21: PREX Issues

Difference between cavity and stripline position for one slug

See oscillationIn time (beatFrequency)

See the sameIn the current

Page 22: PREX Issues

Frequency of noise not stablePlot every fourth point to slow observed frequency and see long times