PlantPAx Distributed Control Sysytem Publication IASIMP-QR006A-EN-P – September 2017 IN1 NTP FAULT FWD HERTZ Enet LINK Sel Esc PORT MOD NET A NET B 527 Stratix 5400 Logix5585 Engineering Workstations Operator Workstations IN2 IN1 Ref Domain Controller Process Automation and Application Servers Process Automation and Application Servers 13 14 58 91 2 10/100/1000 PoE+ 100/1000 SFP 100/1000 SFP+ GPS ANT. DIG.TimeCode ANA.TimeCode Console Alarm TOD 16 17 20 21 24 25 OUT IN OUT IN 28 Disp. Mode 13 14 58 91 2 10/100/1000 PoE+ 100/1000 SFP 100/1000 SFP+ GPS ANT. DIG.TimeCode ANA.TimeCode Console Alarm TOD 16 17 20 21 24 25 OUT IN OUT IN 28 Disp. Mode IN2 IN1 Ref Com IN2 IN1 Ref NTP Logix5585 PTP NTP Com IN2 IN1 Ref Intelligent Motor Control Devices IN2 IN1 Ref Logix5585 Logix5585 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 Process Control I/O Network Com IN2 IN1 Ref Com IN2 IN1 Ref Logix5585 Intelligent Electrical Protection Devices Virtual LANs will provide the proper automation system segregation, where the critical communications should be in the subnet Management (300) Native - Trunk (301) Supervisory Network (501) MCC I/O Network (502) Process I/O Network (503) RTU I/O Network (504) IEC61850 Network (505) VLAN Segmentation Process Controllers will be responsible to handle Process I/O and Motor Control Center Routing capabilities such as Hot Standby Routing Protocol (HSRP) should be used in secondary activities The Domain Controller is responsible for propagating the system time to computers and network infrastructure devices. Network Time Protocol (NTP) source can be internal or external, the GPS source (internal) is preferable in system where the time synchronization is critical The PlantPAx Distributed Control System is a modern DCS which is scalable, flexible, and open while providing the reliability, functionality, and performance expected from a DCS. The PlantPAx System is capable of integrating control systems on process skidded equipment, process instrumentation, intelligent motor control and intelligent electrical protection devices. This drawing depicts a typical reference architecture for the PlantPAx System. Skids of electrical protection devices can now be easily integrated into the PlantPAx System providing a holistic view of your plant’s operations from power infrastructure through process control equipment.

Upload: buiphuc

Post on 27-Jul-2018

345 views

Category:

Documents


14 download

TRANSCRIPT

Page 1: PlantPAx Distributed Control Sysytemliterature.rockwellautomation.com/idc/groups/literature/documents/... · IEC 61850 to EtherNet/IP Gateway Stratix 5700 Managed Switch ControlLogix

PlantPAxDistributed Control SysytemPublication IASIMP-QR006A-EN-P – September 2017

Com

IN2

IN1Ref

NTP

FAULT

FWDHERTZ

Enet LINK

SelEsc

PORTMODNET ANET B527

Stratix 5400

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

EngineeringWorkstations

OperatorWorkstations

Com

IN2

IN1Ref

DomainController

Process Automationand ApplicationServers

Process Automationand Application

Servers

EIP

Mod

EIP

Net

Setu

pG

PSTi

meC

D3

14

2O

ut1

2

Spee

dDu

plex

PRP

DLR

PoE

Alarms PSU

12 3456 78 91 01 11 22 52 6

13

14 58 91 210/100/1000 PoE+

100/1000 SFP 100/1000 SFP+

GPS ANT. DIG.TimeCode ANA.TimeCode

Console Alarm

TOD

16 17 20 21 24 25

OUT

IN

OUT

IN

28

272421 22 232017 18 191613 14 15 28

ExpressSetup

Disp.Mode

EIP

Mod

EIP

Net

Setu

pG

PSTi

meC

D3

14

2O

ut1

2

Spee

dDu

plex

PRP

DLR

PoE

Alarms PSU

12 3456 78 91 01 11 22 52 6

13

14 58 91 210/100/1000 PoE+

100/1000 SFP 100/1000 SFP+

GPS ANT. DIG.TimeCode ANA.TimeCode

Console Alarm

TOD

16 17 20 21 24 25

OUT

IN

OUT

IN

28

272421 22 232017 18 191613 14 15 28

ExpressSetup

Disp.Mode

Com

IN2

IN1Ref

Com

IN2

IN1Ref

NTP

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

PTP

NTP

Com

IN2

IN1Ref

R

Intelligent MotorControl Devices

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

34

1625

34

1625

34

1625

34

1625

34

1625

34

1625

34

1625

34

1625

34

1625

HealthyReady

Run

SystemHealthyForce

Aux

Serial 1Serial 2

Ethernet 1Ethernet 2

Fault Reset

1715-AENTR

ADAPTER

HealthyReady

Run

SystemHealthyForce

Aux

Serial 1Serial 2

Ethernet 1Ethernet 2

Fault Reset

1715-AENTR

ADAPTER

HealthyReady

Run

Channel 01Channel 02Channel 03Channel 04Channel 05Channel 06Channe l07Channel 08

Channel 09Channel 10Channel 11Channel 12Channel 13Channel 14

Channel 15Channel 16

HealthyReady

Run

Channel 01Channel 02Channel 03Channel 04Channel 05Channel 06Channe l07Channel 08

Channel 09Channel 10Channel 11Channel 12Channel 13Channel 14

Channel 15Channel 16

HealthyReady

Run

Channel 01Channel 02Channel 03Channel 04Channel 05Channel 06Channe l07Channel 08

Channel 09Channel 10Channel 11Channel 12Channel 13Channel 14

Channel 15Channel 16

HealthyReady

Run

Channel 01Channel 02Channel 03Channel 04Channel 05Channel 06Channe l07Channel 08

Channel 09Channel 10Channel 11Channel 12Channel 13Channel 14

Channel 15Channel 16

Process Control I/O Network

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

Intelligent ElectricalProtection Devices

Virtual LANs will provide theproper automation system

segregation, where the criticalcommunications should be in the subnet

Management (300)Native - Trunk (301)Supervisory Network (501)MCC I/O Network (502)Process I/O Network (503)RTU I/O Network (504)IEC61850 Network (505)

VLAN Segmentation

Process Controllers will beresponsible to handle

Process I/O and Motor Control Center

Routing capabilitiessuch as Hot Standby

Routing Protocol(HSRP) should be usedin secondary activities

The Domain Controller isresponsible for propagating thesystem time to computers andnetwork infrastructure devices.

Network Time Protocol (NTP)source can be internal orexternal, the GPS source

(internal) is preferable in systemwhere the time synchronization

is critical

The PlantPAx Distributed ControlSystem is a modern DCS which isscalable, flexible, and open whileproviding the reliability, functionality,and performance expected from aDCS. The PlantPAx System is capableof integrating control systems onprocess skidded equipment, processinstrumentation, intelligent motorcontrol and intelligent electricalprotection devices. This drawingdepicts a typical referencearchitecture for the PlantPAx System.

Skids of electrical protectiondevices can now be easily

integrated into the PlantPAxSystem providing a holistic viewof your plant’s operations frompower infrastructure throughprocess control equipment.

Page 2: PlantPAx Distributed Control Sysytemliterature.rockwellautomation.com/idc/groups/literature/documents/... · IEC 61850 to EtherNet/IP Gateway Stratix 5700 Managed Switch ControlLogix

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

To trusted network

ProSoftIEC 61850 toEtherNet/IP

Gateway

Stratix 5700ManagedSwitch

ControlLogixController

Cisco IE2000U

ManagedSwitch

IED IED

IED IED

Electrical Distribution System Typical

The dashed box represents the IntelliCENTER Integration Unit is a configured to order product provided by Rockwell Automation to interface the plant control system with the power distribution system via the IEC 61850 standard. The integration unit is flexible and configurable based upon the needs for your powermanagement and electrical SCADA system. For more information on the configuration options for the IntelliCENTER Integration Unit please see http://literature.rockwellautomation.com/idc/groups/literature/documents/rm/3300a-rm001_-en-p.pdf or your local distributor or Rockwell Automation representative. This architecture drawing represents the IntelliCENTER Integration Unit interfacing over a trusted network to the larger control system.

The Allen-Bradley® Stratix 5700™ is a compact, scalableLayer 2 managed switch with embedded Cisco technologyfor use in applications with small isolated, to complexnetworks. With integration into Studio 5000 AutomationEngineering and Design Environment™, you can leverageFactoryTalk® View faceplates and Add-on Profiles forsimplified configuration and monitoring.By choosing a switch co-developed by RockwellAutomation and Cisco, your Operations Technology (OT)and Information Technology (IT) professionals leveragetools and technology that are familiar to them. Thiscollaboration can also help to reduce configuration timeand cost.

The ProSoft PLX82-EIP61850 is a stand alone gateway module that is capable of converting IEC 61850 traffic to EtherNet/IP traffic to be consumed by the Rockwell Automation control system. This module acts as an IEC 61850 MMS client and IEC 61850 GOOSE Subscriber. The IEC 61850 information is configured and exports Add On Instructions (AOIs) that are consumed by the controller. For sizing of the ProSoft Modules see the IntelliCENTERIntegration Unit Reference Manual. For more information on the ProSoft Gateway Module see: https://www.prosoft-technology.com/ Products/Gateways/EtherNet-IP/EtherNet-IP-Server-to-IEC- 61850-Client-Gateway

Skids of electrical protection devices can now be easilyintegrated into the PlantPAx system providing a holisticview of your plant’s operations from power infrastructurethrough process control equipment.

When designing an IEC 61850 network make surethat the network infrastructure supports the protocolswithin the standard. Rockwell Automation recommendsusing the Cisco IE 2000U as it supports an IED SmartportMacro and prioritizes IEC 61850 within its Quality ofService. More information about the IE 2000U pleasefollow: https://www.cisco.com/c/en/us/products/switches/industrial-ethernet-2000u-series-switches/index.html

IEDs or Intelligent Electrical Devices are devices that haveprotective electrical functions or metering capabilities.These devices then communicate this information via anEthernet network. This drawing represents IEDscommunicating to the IntelliCENTER Integration Unit viathe IEC 61850 standard. The PlantPAx Library for ElectricalProtection Devices hosts a variety of faceplates thatvisually represent IEDs. This library can be found athttp://literature/rockwellautomation.com/idc/groups/literature/documents/rm//process-rm011-en-p.pdf/

Stratix 5700

ProSoft PLX82-EIP61850

Page 3: PlantPAx Distributed Control Sysytemliterature.rockwellautomation.com/idc/groups/literature/documents/... · IEC 61850 to EtherNet/IP Gateway Stratix 5700 Managed Switch ControlLogix

UntrustedWide Area Network

EngineeringWorkstations

OperatorWorkstations

Remote Control Center

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

To untrusted network

Com

IN2

IN1Ref IFW

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

To untrusted network

Com

IN2

IN1Ref IFW

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

To untrusted network

Com

IN2

IN1Ref IFW

Untrusted Network Typical

In a typical untrusted Wide Area Network, the networkinfrastructure between Point A and Point B is not owned bythe user. This media is often shared with other networktraffic and therefore is known as an untrusted network.The IntelliCENTER Integration Unit can be configured tohand this network topology by adding a Stratix 5950Security Appliance as the interface between the IntegrationUnit and the untrusted network.

The IntelliCENTER Integration Unit is a configured to orderproduct provided by Rockwell Automation to interface theplant control system with the power distribution systemvia the IEC 61850 standard. The integration unit is flexibleand configurable based upon the needs for your powermanagement and electrical SCADA system. For moreinformation on the configuration options for theIntelliCENTER Integration Unit please see www.ab.com/product_name_here or your local distributor or RockwellAutomation representative. This architecture drawingrepresents the IntelliCENTER Integration Unit interfacingover an un-trusted network to the larger control system.

IntelliCENTER Integration Unit

Page 4: PlantPAx Distributed Control Sysytemliterature.rockwellautomation.com/idc/groups/literature/documents/... · IEC 61850 to EtherNet/IP Gateway Stratix 5700 Managed Switch ControlLogix

ProSoft PLX82-EIP61850

Stratix 5700

Stratix 5950

Com

IN2

IN1Ref

Com

IN2

IN1Ref

RUNP ROGREM

Logix5585

NET

LINK

SAFETY ON

To untrusted network

ProSoftIEC 61850 toEtherNet/IP

Gateway

Stratix 5700ManagedSwitch

ControlLogixController

Cisco IE2000U

ManagedSwitch

IED IED

IED IED

Com

IN2

IN1Ref

Stratix 5950SecurityAppliance

IFW

Electrical Distribution System Typical

The Allen-Bradley® Stratix® 5950 security appliancecombines several enhanced security functions into a singleappliance to help protect your industrial automationinfrastructure.

The Stratix 5950 security appliance leverages Cisco ASAFirewall technology, which provides the ability to controlnetwork traffic through configured security rules. CiscoFirePOWER™technology in the Stratix 5950 provides anIntrusion Prevention System (IPS) used to detect andcontrol application-level network communications andpotentially malicious traffic communicating through thenetwork.

The Allen-Bradley® Stratix 5700™ is a compact, scalableLayer 2 managed switch with embedded Cisco technologyfor use in applications with small isolated, to complexnetworks. With integration into Studio 5000 AutomationEngineering and Design Environment™, you can leverageFactoryTalk® View faceplates and Add-on Profiles forsimplified configuration and monitoring. By choosing a switch co-developed by Rockwell Automation and Cisco, your Operations Technology (OT) and Information Technology (IT) professionals leverage tools and technology that are familiar to them. This collaboration can also help to reduce configuration time and cost.

The ProSoft PLX82-EIP61850 is a stand alone gatewaymodule that is capable of converting IEC 61850 traffic toEtherNet/IP traffic to be consumed by the RockwellAutomation control system. This module acts as an IEC61850 MMS client and IEC 61850 GOOSE Subscriber. TheIEC 61850 information is configured and exports Add OnInstructions (AOIs) that are consumed by the controller.For sizing of the ProSoft Modules see the IntelliCENTERIntegration Unit Reference Manual. For more informationon the ProSoft Gateway Module see: https://www.prosoft-technology.com/Products/Gateways/EtherNet-IP/EtherNet-IP-Server-to-IEC-61850-Client-Gateway

Skids of electrical protection devices can now be easilyintegrated into the PlantPAx system providing a holisticview of your plant’s operations from power infrastructurethrough process control equipment.

When designing an IEC 61850 network make surethat the network infrastructure supports the protocolswithin the standard. Rockwell Automation recommendsusing the Cisco IE 2000U as it supports an IED SmartportMacro and prioritizes IEC 61850 within its Quality ofService. More information about the IE 2000U pleasefollow: https://www.cisco.com/c/en/us/products/switches/industrial-ethernet-2000u-series-switches/index.html

IEDs or Intelligent Electrical Devices are devices that haveprotective electrical functions or metering capabilities.These devices then communicate this information via anEthernet network. This drawing represents IEDscommunicating to the IntelliCENTER Integration Unit viathe IEC 61850 standard. The PlantPAx Library for ElectricalProtection Devices hosts a variety of faceplates thatvisually represent IEDs. This library can be found atwww.ab.com/processlibrary.

The IntelliCENTER Integration Unit is a configured to orderproduct provided by Rockwell Automation to interface theplant control system with the power distribution systemvia the IEC 61850 standard. The integration unit is flexibleand configurable based upon the needs for your powermanagement and electrical SCADA system. For moreinformation on the configuration options for theIntelliCENTER Integration Unit please see www.ab.com/product_name_here or your local distributor or RockwellAutomation representative. This architecture drawingrepresents the IntelliCENTER Integration Unit interfacingover an un-trusted network to the larger control system.