Q X G PHABRIX Qx Operation Manual Software Release 1.0.3 Manual Revision 4 PHABRIX ® ® broadcast excellence Copyright © PHABRIX Ltd 2017 PHQX-01, PHQX-01E

Upload: others

Post on 01-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • QX

    G

    PHABRIX Qx Operation ManualSoftware Release 1.0.3

    Manual Revision 4

    PHABRIX®®

    broadcast excellence

    Copyright © PHABRIX Ltd 2017PHQX-01, PHQX-01E

  • PHABRIX Qx Operation Manual Page II

    About this ManualNotice

    The information in this document has been produced by PHABRIX Ltd with care and is believed to be accurate. PHABRIX Ltd does not assume responsibility for loss or damage resulting from errors, omissions or inaccuracies herein. This document is subject to change and revisions may be made and issued to include such changes.

    No part of this document may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, recorded or otherwise without the prior written consent of PHABRIX Ltd.

    Copyright © PHABRIX Ltd. All rights reserved. Software products licensed are owned by PHABRIX Ltd and are protected by international treaty provisions and national copyright laws.

    HDMI ® is the registered trademark of HDMI Licensing and is used within the document for identification purposes only.

    Revision

    This manual is a revision controlled document. Any changes to any page content will be reflected in the overall revision status of the whole manual.

    Release Date Software Version Comment

    1 23 Jan 2017 1.0.0.196 First release of manual

    2 21 Mar 2017 1.0.1.227 Addition of Waveform, Vectorscope, HDMI audio and new video standards

    3 20 Jun 2017 1.0.2 Reference locking support with Output offset adjustment. Input timing against reference with Input Measurement Offset.

    4 21 Aug 2017 1.0.3 HDR Heat-map, CIE 1931 x y Chart, HDR/WCG additions for Waveform and Vectorscope, and new PQ video standards. REST API for remote control and automation. CRC Analysis frame change detection added.

    PHABRIX® Limited

    Omega House, Enterprise Way, Thatcham, Berkshire RG19 4AE United Kingdom

    phone + 44 (0)1635 873030 email: [email protected] www.phabrix.com

  • PHABRIX Qx Operation Manual Page III

    Getting StartedPackage Contents

    The shipping box should contain the following

    PHABRIX Qx unit: PHQX-01 or PHQX-01E (with Physical Layer Analysis)

    Power Supply Unit

    Mains lead

    General Safety

    Avoiding Personal Injury This instrument is designed for use by qualified personnel only.

    No user serviceable parts are provided. Units should be returned to your local PHABRIX agent for servicing.

    The Operator should NOT remove the case from the unit.

    Do not spill any liquid onto the unit or its power adaptor.

    Power SupplyMake sure that the unit is connected to the correct power supply voltage. A power supply adaptor is supplied with the unit which may be connected to any AC power supply between 100 and 240VAC at 50-60Hz. Only the supplied power adaptor should be used with the unit. Do not use a damaged AC cable with the unit as it may cause a shock or fire hazard. Replacement AC cables are available from your local PHABRIX agent.

    How to upgrade software

    New software releases will be made available regularly as the product develops.

    Software downloads are approximately 100 MB and can be found in the Support area of the PHABRIX website currently located at www.phabrix.com/support.asp

    Download the file to any FAT32 formatted USB stick.

    Make sure the unit is turned OFF before upgrading.

    Insert the USB into the front panel USB port.

    Press the start button TWICE in succession. The start button will glow pink when the upgrade procedure begins. If the button doesnt glow pink then repeat the procedure.

    The start button will flash several colours and the fans will be on full throughout the upgrade process. Please wait approximately 4 minutes as the unit upgrades. It will automatically show the menu screen when complete.

  • PHABRIX Qx Operation Manual Page IV

    Installation Environment

    Operating Temperature

    The unit should only be operated between 0 and 40 °Celsius. If the unit is operated at a higher temperature there is a possibility of a fire hazard. If the temperature is changed rapidly from a cold environment to a hot environment, moisture can be created internally which can cause malfunction or damage the unit. Allow the unit to sit for 30 minutes without power applied to reduce any possibility of condensation. If the internal temperature rises above 65°Celsius the unit will turn OFF automatically.

    Input/Output TerminalsDo not connect the input or output BNC connectors to external power as this can damage the internal circuitry and cause the unit to work incorrectly.

    The BNC connectors fitted on this unit are 75Ω type which are not compatible with 50Ω plugs.

    The use of 50Ω plugs will permanently damage the connectors on the unit. The use of 50Ω plugs is considered to be misuse of the equipment and will therefore invalidate the unit’s warranty.

    When Not In UseDisconnect the unit from the power supply and AC power source when not in use.

    MaintenanceWipe the case gently with a soft cloth, lightly dampened with a neutral cleaning agent.

    Remove the power supply from the unit and turn OFF before cleaning. Do not allow any water or other liquid to enter the unit while cleaning.

    RoHS Compliance

    PHABRIX products are designed and manufactured using only RoHS compliant components and materials. Therefore based on information provided by our suppliers, PHABRIX certifies that ALL products that it manufactures are “RoHS-5” compliant and that they do not exceed the designated levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether flame retardants (PBDE) legislated under the provisions of the “European Parliament and Council Directive” on the “Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (2011/65/EC)” and associated regulations collective known as the “RoHS Regulations”.

    Disposal of Equipment

    This product is subject to the European WEEE (Waste Electrical and Electronic Equipment) directive and should be disposed of according to the regulations of each country.

  • PHABRIX Qx Operation Manual Page V

    Contents

    Getting Started III

    Package Contents ....................................................................................................... IIIGeneral Safety............................................................................................................ III

    Avoiding Personal Injury ........................................................................................ IIIPower Supply ........................................................................................................ III

    How to upgrade software ........................................................................................... IIIInstallation Environment ............................................................................................IV

    Operating Temperature .........................................................................................IVInput/Output Terminals ..........................................................................................IVWhen Not In Use ...................................................................................................IVMaintenance .........................................................................................................IV

    RoHS Compliance.......................................................................................................IVDisposal of Equipment ...............................................................................................IVIcon display and meaning ..........................................................................................VII

    Overview 1

    Start up....................................................................................................................... 1Installation ............................................................................................................. 1Analyser SDI connections ....................................................................................... 1Generator SDI connections ..................................................................................... 2Powering up the Qx ................................................................................................ 2Menu selection ....................................................................................................... 2Instrument Launch Menu ........................................................................................ 2

    Instrument Description 5

    Generator - Configuration ............................................................................................ 6Pathological signal insertion................................................................................... 7Output offset adjustment ....................................................................................... 7

    Generator - Status ....................................................................................................... 8

    System IO (SDI) ........................................................................................................... 9Analyser - Configuration ............................................................................................ 10Stats - SDI In A, B, C, D ............................................................................................. 11

    Analyser - Picture ..................................................................................................... 12Blanking Area ...................................................................................................... 12HDR Heat-map (False Colour Overlay) ................................................................. 13Transfer Curve and Colourimetry Overrides .......................................................... 14

    Analyser - CIE Chart .................................................................................................. 14Analyser - Waveform ................................................................................................. 15Analyser - Vectorscope .............................................................................................. 16

    Eye - SDI in A (PHQX-01E only) ................................................................................. 17Jitter - SDI In A (PHQX-01E only) .............................................................................. 19

    Analyser - Dataview ................................................................................................... 20

  • PHABRIX Qx Operation Manual Page VI

    Timing and System Reference ................................................................................... 21System Reference Lock ........................................................................................ 21SDI A vs System Reference ................................................................................... 21Input Measurement Offset ................................................................................... 21SDI Co-Timing ....................................................................................................... 22

    Analyser - Ancillary Status ......................................................................................... 22Analyser - Audio Meters ............................................................................................ 23Analyser - CRC Analysis ............................................................................................. 24

    Event Logging ........................................................................................................... 24Network Status ......................................................................................................... 25

    REST API Requests ............................................................................................... 26

    Time and NTP ........................................................................................................... 26

    Specifications ............................................................................................................ 28

    On-going Development.............................................................................................. 31

    Supported SDI standards .......................................................................................... 32

  • PHABRIX Qx Operation Manual Page VII

    Icon display and meaning

    Eye - SDI In A

    Jitter - SDI In A

    System IO (SDI)

    Stats - SDI In A

    Stats - SDI In B

    Stats - SDI In C

    Stats - SDI In D

    Timing and System Reference

    Analyser - Configuration

    Analyser - Ancillary Status

    Analyser - Audio Meters

    Analyser - CIE Chart

    Analyser - CRC Errors

    Analyser - Dataview

    Analyser - Picture

    Analyser - Vectorscope

    Analyser - Waveform

    Generator - Configuration

    Generator - Status

    Event Logging

    Network Status

  • PHABRIX Qx Operation Manual Page 1

    OverviewStart up

    InstallationThe rear of the unit shown above describes the connections and interfaces of the Qx.

    Before turning on the Qx, make sure the following connections are in place:

    The XLR power cable is inserted.

    For instrument display connect a suitable 1920 x 1080 capable monitor to either the HDMI instrument output or the SDI instrument output. The monitor output can be configured for 1080p60, 1080p59.94 or 1080p50 frame rates using ‘Display Options’ submenu of the ‘Instrument Launch Menu’.

    For mouse and keyboard control, the two USB ports at the rear of the unit should be used.

    Note: The following interfaces are temporarily unavailable in this release of software:

    • SFP A and SFP B

    • LTC In

    • GPI I/O

    • AES I/O

    Analyser SDI connectionsAnalyser

    The Physical Layer connection for eye and jitter outlined in red is the furthest right BNC with a red nut. This provides the multi rate eye and jitter connection from HD-SDI to 12G-SDI.

    There are four 12G-SDI capable input BNC’s for the analyser SDI IN A, B, C, D.

    Up to four SDI inputs may be connected at any one time however the system will automatically determine the signal set to analyse be it single link, dual link or quad link based on the SMPTE ST 352 packets present. The algorithm looks to ‘SDI IN A’ first and then determines the overall standard.

    If the SMPTE ST 352 packets are known to be incorrect then the user has the option to select ‘Ignore payload identifier packets (ST 352)’ in the ‘Analyser Configuration’ window.

    Generator 12G/6G/3G/HD BNC x4

    Analyser inputs 12G/6G/3G/HD BNC x4

    (SFP+) MSA/NON-MSA 12Gbps copper or fibre, 10G Ethernet

    Networking 10/100/1000BASE-T

    2x USB 2.0 SDI instrument output

    Ref loop BNC x 2

    HDMI instrument output (to 1080p60)

    Stereo Audio out, LTC in,8x GPI I/O, 4x AES I/O

    Power 10 - 18v

    Micro USB (Factory service)

    •••••

    • • • • • • • •• •

    ••

    •• •

    12G/6G/3G/HD Eye

  • PHABRIX Qx Operation Manual Page 2

    Generator SDI connectionsThe generator provides up to four SDI output signals which must form part of the same video signal set e.g. 12G payload using four 3G-SDI outputs or 12G payload using two 6G-SDI signals.

    ‘SDI OUT A’ is always present and carries the first signal in the group. ‘SDI OUT B’ is active for dual link standards and ‘SDI OUT C’ and ‘SDI OUT D’ are active for quad link standards.

    Powering up the QxWhen the ‘Power Button’ on the Qx is first pressed, the unit fans will cycle for 20-30 seconds at high speed as the system boots then settle to their normal operating speed.

    Menu selectionThe following menu screen will be displayed after power up:

    To activate the ‘Instrument Launch Menu’ left click the PHABRIX symbol on the ‘Instrument Bar’

    To hide the ‘Instrument Bar’ left click within its blank area

    Bringing the cursor to the bottom of screen re-enables the ‘Instrument Bar’

    Instrument Launch Menu

    Power Button

    USB port

  • PHABRIX Qx Operation Manual Page 3

  • PHABRIX Qx Operation Manual Page 4

    As each instrument is selected, an icon will be placed on the ‘Instrument Bar’. The instrument and icon will be assigned a colour. Each icon will glow in the assigned colour to indicate if it is part of a ‘group’ of instruments related to analyser, generator, or system.

    Instruments automatically group by colour. If one instrument is placed next to another then the border will outline all instruments of a common group in contact with each other to aid group recognition.

    Each instrument also has a sub menu. The sub menu is activated by right clicking the mouse in the window enabling a drop down configuration menu. Click and drag on the grey bar at the top of the sub menu to move it. In addition to window specific commands, the option to ‘Close’ the instrument is provided in its sub menu.

    Double clicking within a window will cycle through a set of standard instrument sizes. In many cases the size of a window can be further adjusted to suit requirements. Click and drag on an instrument’s surface to reposition the instrument.

  • PHABRIX Qx Operation Manual Page 5

    right click mouse for additional drop down menus

    Example of drop down menu on right mouse click:

    211 mm

    249

    .3 m

    m

    44

    mm

    9.81

    5 "

    1.73

    2 "

    8.307 "

    211 mm

    249

    .3 m

    m

    44

    mm

    9.81

    5 "

    1.73

    2 "

    8.307 "

    211 mm

    249

    .3 m

    m

    44

    mm

    9.81

    5 "

    1.73

    2 "

    8.307 "

    211 mm

    249

    .3 m

    m

    44

    mm

    9.81

    5 "

    1.73

    2 "

    8.307 "

    Connect generator to

    analyser

    211 mm

    249.3 mm

    44 m

    m

    9.815 "1.732 "

    8.307 "

    SDI OUT

    (Generator)

    SDI IN

    (Analyser)

    Instrument Description

    The guide that follows is intended as an introduction to the menu selection and the tool-set. The Qx has the advantage of being a generator and an analyser so this tour of the product will be using both tool-sets simultaneously.

    For this guide we will assume that you have connected the unit to itself as shown in the following diagram.

  • PHABRIX Qx Operation Manual Page 6

    GenerationGenerator - Configuration

    The ‘Generator Configuration’ window is used to select the generator video standard and test pattern. Once selected the new test signal is loaded by pressing the ‘Generate’ pane.

    Note: In this software revision the generator takes approximately 8 seconds to load after which the eye and jitter toolset will be enabled. During this period all other analyser functions are disabled.

    Right clicking anywhere within the generator window brings up a configuration menu.

    To simplify selection the generator standards list may be filtered using the following settings:

    • Filter video standard list > Frame Rate > [No filter, 23.98, 24, 25, 29.97, 30, 47.95, 48, 50, 59.94, 60]

    • Filter video standard list > Colour Format > [No filter, YCbCr:422, YCbCrA:4444, RGBA:4444, YCbCr:444, RGB:444, YCbCrA:4224

    • Filter video standard list > Bit depth > [No filter, 10, 12]

    • Filter video standard list > Active Lines > [No filter, 720, 1080, 2160]

    • Filter video standard list > Sub Image Format > [No filter, Single Image, square division, 2 Sampl...erleave]

    • Filter video standard list > Level > [No filter, A, B]

    • Filter video standard list > Combined SDI rate > [No filter, 1.5G, 3G, 6G, 12G]

    • Filter video standard list > Source image width > [No filter, 1280, 1920, 2048, 3840, 4096]

    • Filter video standard list > Interlace > [No filter, progressive, interlaced, segmented]

    • Filter video standard list > Link Count > [No filter, 1, 2, 4]

    • Filter video standard list > Transfer Curve > [No filter, SDR-TV, PQ]

    Filters are removed by selecting in menu:

    • Filter video standard list > Clear filters

    Generator toolset border colour selection is provided for clear identification:

    • Generator tools colour select, [colour]

  • PHABRIX Qx Operation Manual Page 7

    Colour selection is via the HSV tool shown above using two cursors. The left hand colour rectangle allows selection of hue (horizontal) and saturation (vertical). The right hand vertical bar selects luminance.

    Pathological signal insertionPathological Signal Insertion is a powerful feature.

    In addition to selecting a background test pattern a pathological pattern may be added as an overlay.

    • Pathological insertion, [Enabled, Disabled]

    Three types of pattern are supported:

    • Pathological insertion, Pattern to overlay, [EQ, PLL, CheckField]

    The amount of pathological pattern may be configured to enable the user to verify how sensitive the SDI link is to pathological conditions on the interface:

    • Pathological insertion, Pairs to insert, [0 to 16384]

    This control limits at the selected formats line length.

    Note: Pathological signals are approved by SMPTE for use with HD and 3G level A standards only. For 3G level B, 6G and 12G-SDI interface formats pathological signals can still be used but are not approved by SMPTE (as of February 2017). It is believed that inserting a full line of pathological signal in these non-approved standards is too stressful a test for the SDI interface. No physical damage will occur but the interface may exhibit reduced operating performance in the form of bit errors.

    Output offset adjustmentA signal can be generated with a fixed offset relative to the system reference.

    Offsets can be entered in temporal or spatial terms:

    • Output offset adjustment > Offset Type > [Time, Lines And Pixels]

    Selecting ‘Time’ reveals a drop down field where the timing offset can be set in microseconds:

    • Output offset adjustment > Offset Type > Time > Output Time Offset > [0.00, +/- 0.01, etc...]

    Selecting ‘Lines And Pixels’ reveals drop down fields where the offset can be set in these terms:

    • Output offset adjustment > Offset Type > Lines And Pixels > Output Line Offset > [0 to +/- (Total no. of Lines for current standard -1)]

    • Output offset adjustment > Offset Type > Lines And Pixels > Output Pixel Offset >[0 to +/- (Total no. of Pixels per Line for current standard -1)]

    Generator offset is removed by selecting in menu:

    • Output offset adjustment > Clear offsets

  • PHABRIX Qx Operation Manual Page 8

    GenerationGenerator - Status

    The ‘Generator - Status’ menu shows the generator pattern selected and confirms the SDI OUT A, B, C or D presence and Sub Image mapping information. This window is status only, there are no user configurations.

  • PHABRIX Qx Operation Manual Page 9

    SystemSystem IO (SDI)

    Due to the complexity of the UHDTV standards, PHABRIX has introduced innovative ways of displaying status. This however does involve the information being displayed across several instruments. The ‘System IO (SDI)’ window has been designed as a quick view of the signal inputs and outputs attached to the Qx.

    Active SDI inputs and outputs are indicated by the coloured connectors. Greyed out connectors indicate signals not present. The colour of the connectors corresponds to the colour of the instrument borders and instrument icons to aid recognition.

    The presence of external reference and its standard is also displayed graphically with a coloured connector. If the system is set to lock to the external reference and a stable lock has been achieved, then the inner ring of the EXT REF BNC pictured will be highlighted in Grey.

    • BNC image: [Grey (reference connected), Red (error with reference), Black (no reference connected]

    Note: The EXT REF BNC shows the status of external reference only; which is not neccessarily the system reference. System reference is selectable in the ‘Timing and System Reference’ instrument.

    Below the graphical connector display is a table showing SDI input and output status, and external reference standard and status. The external reference field displays the following states:

    • EXT REF: [No Signal, Unstable, 525/59.94, 625/50, etc...]

    If external reference is not currently being used as system reference, its field text will display in yellow. When external reference is the system reference,this table field text will be white.

  • PHABRIX Qx Operation Manual Page 10

    AnalysisAnalyser - Configuration

    The ‘Analyser - Configuration’ window controls the video standard being analysed. It lists the payloads on the SDI input signals and highlights the ones used by the video standard being analysed.

    The Payloads are identified primarily by ST-352 packets, if these are missing the signal stats will be analysed and a best guess payload identifier will be listed.

    Incorrect ST 352 packets are indicated in red within the ‘Analyser - Configuration’ window.

    • Ignore Payload Identifier Packets (ST 352) > Checkbox [tick = ignore]

    ST-352 packets can be ignored such that a best guess payload identifier is always used. Select the “Ignore Payload Identifier Packets (ST-352)” option from the window’s menu.

    • Analyser tools colour select > [colour]

    Colour selection is via a HSV tool providing two cursors. The left hand colour rectangle allows selection of hue (horizontal) and saturation (vertical). The right hand vertical bar selects luminance.

  • PHABRIX Qx Operation Manual Page 11

    AnalysisStats - SDI In A, B, C, D

    ‘Stats - SDI In A’, B, C and D provide information to verify the format of the signals being analysed. A video signal may be comprised of up to four separate SDI signals hence four separate windows.

    Example 1 shows the display of data from a single 12G input on input A

    Example 2 shows the display of data from a quad 3G input hence 4 separate video status windows

  • PHABRIX Qx Operation Manual Page 12

    AnalysisAnalyser - Picture

    The picture view shows the generator pattern currently being analysed by the Qx. The picture window may default to full screen - simply right click to change the picture to SMALL or MEDIUM. Right click the mouse to select MOVE to reposition the picture anywhere on the display.

    The instrument’s right click submenu provides various setting, including the ability to confidence monitor multi-sub-image video signals:

    • Per Sub-Image Decimation > [Disabled, Enabled]

    With this setting enabled, sub-images are decimated individually and recombined, allowing detection of significant errors in individual sub-images (2SI only).

    Note: The above setting will be available soon in a future software release.

    Blanking AreaBy right clicking with the mouse the operator can also enable ‘Show Blanking’. This will offset the picture to the right revealing the blanking area.

    • Show Blanking > [Disabled, Enabled]

    Note: ‘Show Blanking’ is not available for multiple sub-image video standards as the active picture is separated from the blanking regions during active picture reconstruction.

  • PHABRIX Qx Operation Manual Page 13

    HDR Heat-map (False Colour Overlay)A false colour overlay can be applied to the picture view, to highlight areas of the image that are of particular luminance.

    The picture can be displayed in greyscale. If enabled at the same time as ‘False colour highlighting’, all image elements outside of the enabled false colour overlay luminance range(s) will be displayed in greyscale mode; leaving the false colour highlight elements to stand out more:

    • Greyscale mode > [Enabled, Disabled]

    A scale with numeric and graphic display of the luminance range(s) of the overlay in use, is available:

    • False Colour Overlay Scale > [Enabled, Disabled]

    The required luminance units for the scale can be selected:

    • Luminance Measurement > [Decimal Level, PQ Nits]

    Different types of false colour overlay may be applied to clearly visualise different image details, and a custom mode is provided to allow the creation of a modified or bespoke overlay:

    • False colour ranges > False Colour Highlighting > [Disabled, PQ HDR, SDR All Bands, SDR Shadow, SDR Skin Tones, SDR Highlights, Out of Range, Custom]

    The range(s) and colours of a selected false colour overlay can be modified by adjusting the 7 overlay bands. Up to 7 distinct ranges can be simultaneously enabled in a single overlay. If adjusted, the new or modified overlay will be designated as the ‘Custom’ overlay type.

  • PHABRIX Qx Operation Manual Page 14

    Transfer Curve and Colourimetry OverridesThere is currently no ratified SMPTE standard for HDR payload ID. As a consequence, much HDR content today will contain the SMPTE payload ID for SDR and Rec. 709 colourspace (as ‘standard’).

    Therefore, for accuracy, when analysing most known HDR and WCG content, overrides should be enabled for the appropriate HDR transfer curve, and for WCG colour space:

    • Enable Transfer Curve Override > [Enabled, Disabled]

    • Transfer curve Override > [SDR-TV, PQ]

    • Enable Colourimetry Override > [Enabled, Disabled]

    • Colourimetry Override > [ColRec709, ColUHDTV]

    All Qx HDR test signals contain the HDR payload ID and therefore do not require overrides for analysis.

    AnalysisAnalyser - CIE Chart

  • PHABRIX Qx Operation Manual Page 15

    The CIE 1931 x y chart provides signal colourimetry analysis - complete with WCG and DCI-P3 colour gamut overlays, and Illuminant D65 white point reference.

    CIE Chart setup is accesed by right clicking within the chart area:

    • Rec. 709 Triangle > [Enabled, Disabled]

    • Rec. 2020 Triangle > [Enabled, Disabled]

    • P3 Triangle > [Enabled, Disabled]

    • D65 White Point > [Enabled, Disabled]

    • Single Line Mode > [Enabled, Disabled]

    • Brightness > [slider 1..31]

    • Gamma > [slider 1..255]

    • Persistence [1..255]

    AnalysisAnalyser - Waveform

    Waveform setup is accesed by right clicking within the waveform area:

    • Parade Mode > [YCbCr, Y, Cb, Cr, RGB, GBR, YRGB, YGBR, Red, Green, Blue]

    • V Scale > [% IRE, Hex Value, Decimal Value, Millivolts, PQ Nits]

    • H Scale > [Pixels, % Line]

    • Filter > [Flat, Low Pass, Raw]

    • Single Line Mode > [Enabled, Disabled]

    • H Magnification > [x1, x2, x4]

    • H Position > [slider]

    • V Magnification > [x1, x2, x4]

    • V Position > [slider]

    • Brightness > [slider 1..31]

    • Gamma > [slider 1..255]

    • Persistence [1..255]

    • Monochrome mode [Enabled, Disabled]

  • PHABRIX Qx Operation Manual Page 16

    AnalysisAnalyser - Vectorscope

    Vectorscope setup is accesed by right clicking within the vectorscope area:

    • Targets > [Off, 75%, 100%]

    • I/Q Axes > [Off, I Only, Q Only, Both]

    • Filter > [Flat, Low Pass, Raw]

    • Centre > [Origin, Red, Green, Blue, Magenta, Cyan, Yellow]

    • Single Line Mode > [Enabled, Disabled]

    • Zoom > [slider 0.5..4.0]

    • Brightness > [slider 1..31]

    • Gamma > [slider 1..255]

    • Persistence [1..255]

  • PHABRIX Qx Operation Manual Page 17

    AnalysisEye - SDI in A (PHQX-01E only)

    One of the unique features of the Qx is the PHYSICAL layer analysis tool-set. The PHABRIX Qx contains fundamental technology developed and patented by PHABRIX which makes it unique where physical layer compliance measurements are required up to 12 Gbps.

    The Qx employs an analogue front end providing in excess of 30 GHz bandwidth (5th harmonic of the 6GHz fundamental for 12G-SDI). Featuring PHABRIX RTETM (Real Time Eye) technology the Qx is in a league of its own. More akin to expensive high end oscilloscopes, the Qx provides broadcast engineers with a reliable, instantaneous physical layer display with automatic measurements to SMPTE standards.

    The PHABRIX Qx enables measurement of both overshoot and undershoot along with amplitude, rise time, fall time and delta - compulsory when testing against SMPTE standards and a key differentiator when comparing Qx technology. Accurate measurements are obtained with seconds of connecting an SDI signal making for very fast system testing solution. Out of specification measurements are indicated in red.

    Example 1: 12G-SDI Eye pattern display with 100 kHz jitter filter

    Example 2: 3G-SDI Eye pattern display with 100 kHz jitter filter

    Note: ‘SDI In A’ has a red nut to indicate it is the SDI BNC that has the eye and jitter circuitry behind it

  • PHABRIX Qx Operation Manual Page 18

    The Physical Layer tool-set has several drop down menus selected by a right click of the mouse.

    (A table showing the SMPTE tolerances for each standard is available at the end of this manual.)

    Selections include:

    • Eyes > [1, 2, 3...20]

    • Colour > [Green, Heat, Red, Ferrara, Green-red, Blacklight]

    • Eye and jitter filter > [10Hz, 100Hz, 1kHz, 10kHz, 100kHz]

    • Infinite mode >[Enabled, Disabled]

    The display also provides:

    • Timing jitter thermometer colour coded according to analysed SDI standard

    • Alignment jitter thermometer colour coded according to analysed SDI standard

    • On screen indication of 20% and 80% levels for rise and fall time measurement

    • On screen indication of +10% and -10% levels for overshoot and undershoot analysis

    • Positive and negative amplitude values providing DC offset information

    • Horizontal histogram of eye crossing point (0mV threshold)

    • Vertical histogram providing indication of energy distribution over all samples

  • PHABRIX Qx Operation Manual Page 19

    AnalysisJitter - SDI In A (PHQX-01E only)

    The jitter tool-set is available on the ‘SDI In A’ BNC (the one with the red nut)

    The jitter instrument shows automated measurements to SMPTE standards.

    Readings for each of the filters are shown displayed as an overlay on the right hand side of the instrument.

    Any red text displayed indicates an out of specification reading.

    As with the Eye instrument, further drop down menus are available using the right click on the mouse control:

    • Scale > [sliding scale: Y graticule adjustment from +/- 0.2 UI to +/-8UI]

    • Trigger > [None, Single Line, Two Lines, Single Field, Two Fields, Frame]

    • Eye and jitter filter > [10Hz, 100Hz, 1kHz, 10kHz, 100kHz]

    • Infinite Mode > [Enabled, Disabled]

    • Jitter Colour > Waveform colour selection

    Colour selection is via a HSV tool providing two cursors. The left hand colour rectangle allows selection of hue (horizontal) and saturation (vertical). The right hand vertical bar selects luminance.

    Trigger modes are useful for correlating jitter content to line and frame rate frequencies

  • PHABRIX Qx Operation Manual Page 20

    AnalysisAnalyser - Dataview

    This instrument presents the raw data present in the signal be it HD-SDI, 3G-SDI, 6G-SDI or 12G-SDI. The data can be observed in hexadecimal, decimal or binary formats and the data is navigated by pixel and line selection. The instrument displays the entire video frame complete with active video, TRS words and blanking information.

    By right clicking using the mouse on this instrument, the following drop down menus are presented:

    • Sample > [slider 0 to max_pix_count]

    • Line > [slider 0..max_line_count]

    • Navigate > [calls up navigation pane - see below]

    • Base > [hex, decimal, binary]

    • Field > [Field 1, Field 2] (standard dependant)

    • Sub-Image > [Sub Image 1, Sub Image 2, Sub Image 3, Sub Image 4] (standard dependant]

    Data is presented with a colour coding for both text and background:

    • Foreground colour indicates video sample type: Y (white), Cb (blue), Cr (red)

    • Background colour indicates data type: TRS words (blue), Blanking (black), Active picture (green)

    Changing the window size changes the amount of data displayed.

    A navigation keypad activated by selecting ‘Navigate’ on the top bar of the instrument allows the user to quickly navigate the dataview window.

  • PHABRIX Qx Operation Manual Page 21

    AnalysisTiming and System Reference

    The upper part of the instrument view is devoted to SDI A vs System Reference timing comparision; and system reference is set in the instrument sub menu.

    The lower part displays SDI Co-timing information for elements of a quad or dual link signal.

    System Reference LockThe sub menu accessed by right clicking within the ‘Timing and System Reference’ window calls up system reference locking controls; defining the reference that the Qx system and any signal it generates will be locked to:

    • System Reference > [Free Run, External Reference, SDI]

    • Default To Freerun > [Enabled, Disabled]

    System reference status information is displayed in the upper right hand corner of the instrument, and any reference health state error will be displayed in red.

    SDI A vs System ReferenceThis section of the instrument displays the timing difference betweeen the SDI A input signal and the system reference the Qx is locked to. Both graphic and numeric (spatial and temporal) values are presented by the instrument for this measurement. A relative timing bar tool dynamically measures the timing of ‘SDI In A’ (white triangle) against the system reference (centrally fixed black vertical crosshair).

    The tool can be adjusted to display readings at frame scale, or zoom in all the way to a fraction of a line:

    • Reference Timing Meter Range > [+/- 0.1 line, +/- 0.5 line, +/- 0.5 frame]

    Input Measurement OffsetIn addition to measurement of ‘SDI In A’ against absolute system reference, a system reference offset can also be applied in the tool to measure against. The offset position is indicated on the relative timing bar tool with a black triangle.

    Offsets can be entered in temporal or spatial terms:

    • Input Measurement Offset Type > [Time, Lines And Pixels]

    Selecting ‘Time’ reveals a drop down field where the timing offset can be set in microseconds:

    • Input Measurement Offset Type > Time > Input Measurement Time Offset > [0.00, +/- 0.01, etc...]

  • PHABRIX Qx Operation Manual Page 22

    Selecting ‘Lines And Pixels’ reveals drop down fields where the offset can be set in these terms:

    • Input Measurement Offset Type > Lines And Pixels > Input Measurement Line Offset > [0 to +/- (Total no. of Lines for current standard -1)]

    • Input Measurement Offset Type > Lines And Pixels >Input Measurement Pixel Offset > [0 to +/- (Total no. of Pixels per Line for current standard -1)]

    The input measurement offset can be set to the same position as the current ‘SDI In A’ signal:

    • Set Input Measurement Offset to current

    The input measurement offset is removed by selecting in menu:

    • Clear Input Measurement Offset

    SDI Co-TimingMany of the standards associated with UHDTV are a combination of signals to form the image plane. Relative timing tools indicate that the quad or dual elements creating the single picture are correctly aligned and compared with reference. Both graphic and numeric values are presented by the instrument for this critical measurement. Any red text displayed indicates an out of specification measurement.

    Note: The Timing instrument in this software release is locked to Input A.

    AnalysisAnalyser - Ancillary Status

    The Qx has a sophisticated display to analyse ancillary data in the signal. UHDTV has a new set of rules for carrying this data. The clear graphical representation of this is required to establish compliance. Colour coded signal conditions - present, lost, and error are all available. Additional data is displayed as the instrument is resized.

    • White - Indicates ANC packets present and correct

    • Red - Indicates ANC packets present but in error

    • Yellow - indicates ANC packets present and correct but there has been a previous error

    Status is reset by selecting in menu:

    • Reset

  • PHABRIX Qx Operation Manual Page 23

    AnalysisAnalyser - Audio Meters

    The ‘Analyser - Audio Meters’ instrument displays 16 x audio meters along with peak level indication and audio pair phase indication. In addition dBFS values are indicated at the base of each meter.

    Dolby E, D and D+ streams are detected by the system with Dolby stream indication in blue.

    The HDMI instrument output carries a stereo pair of audio, the same signal is made available on the 26-way D-type at the rear of the Qx chassis.

    Stereo pair monitoring selection is provided by selecting the speaker icon above each set of audio meters. Mono channel selection is provided by selecting the appropriate solo bus located between the audio meters and the speaker icons.

    Menu options provided:

    • Input Select > [Image/Sub-Image 1 Group 1-4, Image/Sub Image 1 Group 5-8, Sub-Image 2 Group 1-4, Sub-Image 2 Group 5-8, Sub-Image 3 Group 1-4, Sub-Image 3 Group 5-8, Sub-Image 4 Group 1-4, Sub-Image 4 Group 5-8]

    • Ballistics > [PPM Type I, PPM Type II, Vu, VuFr]

    • PPM Scale Type > [dBFS, dBu -18dBFS, dBu-20dBFS, BBC, DIN45406, NordicN9]

    • Hat Hold Time > [0.00...10.00, infinity]

    • Monitor Buttons > [Enabled, Disabled]

    • Solo Buttons > [Enabled, Disabled]

    Up to two audio meter instrument windows can be enabled providing 32 simultaneous channels of audio metering. Each window is assignable to monitor groups 1 to 4 (defined in SMPTE ST 299-1) or groups 5 to 8 (defined in SMPTE ST 299-2) in any of up to 4 potential sub-image ANC areas as defined in SMPTE ST 2082-10.

    Each audio window is scalable from 1/32 to 1/4 of screen area.

  • PHABRIX Qx Operation Manual Page 24

    AnalysisAnalyser - CRC Analysis

    The ‘Analyser - CRC Analysis’ window checks for CRC errors in the signal. Dependant on the input required for the standard under test, i.e. 4 inputs or single, the Sub Image columns will show any errors in each of the inputs attached.

    The ‘Last error timer’ event shows in seconds the last CRC error event in each input.

    In addition, a separate timer indicates the time since error checking began.

    The instrument also analyses the CRC of the overall active picture to detect changes.

    • Reset errors and running time

    SystemEvent Logging

    Logging is provided on the Qx, and logs can be viewed in ‘Event Logging’. The Qx allocates 500 lines for logging detail before over writing this data. It will also recall the log data last captured if the unit is started from cold. The setting for logging data will need to be re-entered from a cold start using the right click selection. Logs can also be accessed and saved via the REST API.

  • PHABRIX Qx Operation Manual Page 25

    By right clicking the mouse on this instrument the following drop down menus are presented:

    • Record jitter Timing Logs > [Enabled, Disabled]

    • Record jitter Alignment Logs > [Enabled, Disabled]

    • Record SDI Input Standard Logs > [Enabled, Disabled]

    • Record SDI Input Rate Logs > [Enabled, Disabled]

    • Record Reference Locking Logs > [Enabled, Disabled]

    • Record REST API Request Logs > [Enabled, Disabled]

    • Clear logs

    Event logging will be significantly improved in subsequent software releases.

    SystemNetwork Status

    The Qx can be controlled remotely via REST API, which can be used for automated testing. The network will need to be DHCP enabled, as the IP address of the Qx will be automatically assigned.

    From the ‘Network Status’ window a remote connection can be established by enabling ‘REST API’ in the submenu:

    • REST API > [Disabled, Enabled]

    The ‘Network Status’ window contains all the information on the Qx that is needed in order to send it a REST request. ‘IP Address’ (or ‘mDNS Hostname’ if your client’s host supports it) should be used as the recipient of the request, and ‘REST API Port’ is the port that requests will need to be directed towards.

    The REST API supports two HTTP methods; GET and PUT.

    GET requests can be used to retrieve Qx information and navigate the submenus. PUT requests can be used to modify and control Qx behaviour and actions.

    A web browser can be used to retrieve Information from the Qx with GET requests.

    Any HTTP/1.1 compliant application can be used to control the Qx with both GET and PUT requests.

    PUT and GET requests can be scripted for automated testing.

  • PHABRIX Qx Operation Manual Page 26

    REST API RequestsFor the following REST API request examples, an example IP address (192.168.0.39) and default REST API Port (8080) are used. The base resource to aim requests at is “/api”. The base URL for requests (GET) will be in the format: http://192.168.0.39:8080/api or http://qx-020094.local:8080/api

    REST API requests can be used to:

    • Report the current analysed standard (GET): http://192.168.0.39:8080/api/v1/analyser/status

    • Report the currently generated standard (GET): http://192.168.0.39:8080/api/v1/generator/status

    • Navigate through list of available generator standards (GET): http://192.168.0.39:8080/api/v1/generator/standards. Select from tree and GET again to drill down to appropriate colour format, bit depth, level, SDR or HDR format, and test pattern.

    • Generate a standard (PUT): http://192.168.0.39:8080/api/v1/generator/standards/1920x1080p60/YCbCr%3A422%3A10/3G_A/100%25%20Bars. A pathological overlay, its type and number of pairs can be added by including a raw payload of, for example, {“action”:“start”,“pathological”:{“type”:“CheckField”,“pairs”:100}}

    • View instantaneous Eye readings (GET): http://192.168.0.39:8080/api/v1/eye/status

    • View instantaneous Jitter readings (GET): http://192.168.0.39:8080/api/v1/jitter/status

    • Retrieve the event logs (GET): http://192.168.0.39:8080/api/v1/eventlog/logs

    • Manage the event logs (PUT): http://192.168.0.39:8080/api/v1/eventlog/config/restAPI with a raw payload of {“action”:“enable”} in this example, to enable REST API event logging.

    SystemTime and NTP

    By ‘right clicking’ the time displayed on the right hand side of the menu bar, a separate window will be displayed. Use the slider control to select the required time zone:

  • PHABRIX Qx Operation Manual Page 27

    NTP can be turned off which will then provide manual control of time setting. To return to NTP use the mouse to select the ‘Automatic’ feature.

    • Time Zone > [select zone]

    • Set Time & Date > Automatic [check box]

    • Set Time & Date > Update Now [press to update]

    • NTP Server: > [eg. pool.ntp.org]

  • PHABRIX Qx Operation Manual Page 28

    Specifications

    Power

    Connector 4-pin XLR, Male

    Voltage 10-18V, 12V DC nominal DC Power adapter provided Overvolatge, undervoltage and reverse voltage protection

    External Locking Reference

    Label REF

    Input Signal Tri-level or Bi-Level (black burst) syncs 50/59.94/60Hz

    Connector 2x BNC

    Input Impedance > 10kΩ

    Input Return Loss >40dB to 6MHz (typical)

    Maximum Input voltage +/- 2V

    Specification Tri-level syncs (SMPTE 274M and SMPTE 296M) 600 mV pk-pk PAL Black Burst (ITU 624-4/SMPTE 318) 1V pk-pk, Composite NTSC (SMPTE 170M) 1V pk-pk

    SDI Instrument Output

    Label SDI OUT

    Connector BNC

    Output Impedance 75Ω

    Output Level 800mV p-p +/-10%

    Purpose 3Gbps SDI instrument output

    HDMI Instrument Output

    Label HDMI

    Connector Type A

    Video Format 1920 x 1080 RGB 4:4:4

    Audio Format 4 x PCM stereo audio at 48 KHz

    Purpose Monitor output that allows up to 16 individual instrument panels (or windows) to be displayed.

    USB

    USB USB 2

    USB Connector Type A

    Quantity 3 (1 x front mounted, 2 x rear mounted)

    Purpose Keyboard and mouse control of the HDMI® monitor output of instrument and software installation.

  • PHABRIX Qx Operation Manual Page 29

    Networking

    Ethernet IEEE 802.3 10/100/1000Mb/s (10/100/1000 base-T)

    Ethernet Connector RJ-45

    Rear panel D26

    Label: I/O Expansion

    Connector: 26-way D-type

    Purpose: 8x GPI I/O, 4x AES I/O, LTC input, stereo analogue audio out

    Pin out:

    Pin Number Pin Name Description1 AES_IO0 Bidirectional AES I/O - 75Ohm unbalanced2 AES_IO1 Bidirectional AES I/O - 75Ohm unbalanced3 AES_IO2 Bidirectional AES I/O - 75Ohm unbalanced4 AES_IO3 Bidirectional AES I/O - 75Ohm unbalanced5 LTC_RX_P LTC Receive (RX) P (RS-422 compatible)6 LTC_RX_N LTC Receive (RX) N (RS-422 compatible)7 AUDIO_R Audio Line Out - right8 AUDIO_L Audio Line Out - left9 5V0_GPIO 5V current limited GPIO supply (500mA)10, 11, 12, 13, 14, 15, 16, 17, 18

    GND 0V

    19 GPIO-0 Open drain,10k pull-up to +5V20 GPIO-1 Open drain,10k pull-up to +5V21 GPIO-2 Open drain,10k pull-up to +5V22 GPIO-3 Open drain,10k pull-up to +5V23 GPIO-4 Open drain,10k pull-up to +5V24 GPIO-5 Open drain,10k pull-up to +5V25 GPIO-6 Open drain,10k pull-up to +5V26 GPIO-7 Open drain,10k pull-up to +5V

    AES I/O

    Connector 26-way D-type

    Pins 1 (AES I/O 1), 2 (AES I/O 2), 3 (AES I/O 3), 4 (AES I/O 4)

    Input Impedance 75 Ω terminated

    Maximum Input Voltage +/- 2V

    Input Sample Rate 48kHz synchronous audio

    Input Bit Depth 20bit or 24bit

    Output Sample Rate 48kHz synchronous to system reference

    Output Bit Depth 24bit

    Specification Conforming to AES3-2003 and SMPTE-276M

    Purpose Not currently supported in software

    19

    1018

    26 19202122232425

    11121314151617

    8 7 6 5 4 3 2

  • PHABRIX Qx Operation Manual Page 30

    Longitudinal Timecode (LTC)

    Connector 26-way D-type

    Pins 5 (RX - P), 6 (RX-N)

    Format RS-422 Compatible

    Purpose Not currently supported in software

    Analogue Audio Output

    Connector 26-way D-type

    Pins 7 (Audio Line Out - Right), 8 (Audio Line Out - Left)

    Type Stereo Pair

    Level (1V peak-to-peak analogue audio, full scale 0dBFS)

    Purpose Audio Monitoring output

    GPIO

    Connector 26-way D-type

    Pins 19 (GPIO - 0), 20 (GPIO - 1), 21 (GPIO - 2), 22 (GPIO - 3), 23 (GPIO - 4), 24 (GPIO - 5), 25 (GPIO - 6), 26 (GPIO - 7)

    Format open drain with 10kΩ pull-up to +5 Volts

    Power 5 Volt (pin 9), current-limted GPIO supply for ‘open drain’ input/outputs. 0 Volt/ signal ground (pins 10 to 18)

    Purpose Not currently supported in software

  • PHABRIX Qx Operation Manual Page 31

    On-going Development

    PHABRIX is committed to developing the tool-sets on the Qx to meet the very high expectations of its customers. There will be frequent upgrades which will include improvements to existing instruments and the addition of new ones.

    Please do not hesitate to contact PHABRIX at any time to discuss your requirements for the product or to discuss the current product time-line.

    SMPTE UHDTV: SDI PHYSICAL LAYER-Data Rate 1.485 Gbps 2.97 Gbps 5.94 Gbps 11.88 Gbps

    Standard SMPTE ST292-1:2012 SMPTE ST424:2012 SMPTE ST2081-1,10 SMPTE ST2082-1,10

    Coding Scrambled NRZI Scrambled NRZI Scrambled NRZI Scrambled NRZI

    Amplitude 800 mV +/- 10% 800 mV +/- 10% 800 mV +/- 10% 800 mV +/- 10%

    DC O�set 0.0 V +/- 0.5 V 0.0 V +/- 0.5 V 0.0 V +/- 0.5 V 0.0 V +/- 0.5 V

    Rise/Fall time: < 270 ps < 135 ps < 80 ps < 45 ps

    Rise/Fall time di�erence: < 100 ps < 50 ps < 35 ps < 18 ps

    Over/Under-shoot:

  • PHABRIX Qx Operation Manual Page 32

    SMPTE StandardsLink (Content) Interface Resolution

    SamplingStructure

    PixelDepth Frame/Field Rate

    PQ HDR Available?

    ST 292 (ST 296) HD 1280 x 720 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 30p, 29.97p, 25p, 24p, 23.98p Yes

    ST 292 (ST 274) HD 1920 x 1080 4:2:2 (YCbCr) 10 60i, 59.94i, 50i Yes

    ST 292 (ST 274) HD 1920 x 1080 4:2:2 (YCbCr) 10 30p, 29.97p, 25p, 24p, 23.98p Yes

    ST 292 (ST 2048-2) HD 2048 x 1080 4:2:2 (YCbCr) 10 30p, 29.97p, 25p, 24p, 23.98p Yes

    ST 425-1 (ST 274) 3G Level A,B (1) 1920 x 1080 4:2:2 (YCbCr) 10 60p, 59.94p, 50p Yes

    ST 425-1 (ST 2048-2) 3G Level A,B (1) 2048 x 1080 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 48p, 47.95p Yes

    ST 425-1 (ST 296) 3G Level A (2) 1280 x 7204:4:4 (YCbCr/RGB)4:4:4:4 (YCbCrA/RGBA)

    10 60p, 59.94p, 50p, 30p, 29.97p _

    ST 425-1 (ST 274) 3G Level A (2) 1920 x 10804:4:4 (YCbCr/RGB)4:4:4:4 (YCbCrA/RGBA)

    1060i, 59.94i, 50i30p, 29.97p, 25p, 24p, 23.98p _

    ST 425-1 (ST 2048-2) 3G Level A (2) 2048 x 10804:4:4 (YCbCr/RGB)4:4:4:4 (YCbCrA/RGBA)

    10 30p, 29.97p, 25p, 24p, 23.98p _

    ST 425-1 (ST 274) 3G Level A (3) 1920 x 1080 4:4:4 (YCbCr/RGB) 1260i, 59.94i, 50i30p, 29.97p, 25p, 24p, 23.98p _

    ST 425-1 (ST 2048-2) 3G Level A (3) 2048 x 1080 4:4:4 (YCbCr/RGB) 12 30p, 29.97p, 25p, 24p, 23.98p _

    ST 425-1 (ST 274) 3G Level A (4) 1920 x 1080 4:2:2 (YCbCr) 1260i, 59.94i, 50i30p, 29.97p, 25p, 24p, 23.98p _

    ST 425-1 (ST 2048-2) 3G Level A (4) 2048 x 10804:2:2 (YCbCr)4:2:2:4 (YCbCrA)

    12 30p, 29.97p, 25p, 24p, 23.98p _

    ST 2081-10 M1, (ST 2036-1)

    6G-2SI 3840 x 2160 4:2:2 (YCbCr) 10 30p, 29.97p, 25p, 24p, 23.98p Yes

    ST 2081-10 M1, (ST 2048-1)

    6G-2SI 4096 x 2160 4:2:2 (YCbCr) 10 30p, 29.97p, 25p, 24p, 23.98p Yes

    ST 425-5 (ST 2036-1) Quad-link 3G-A (1) 2SI,SQ 3840 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p Yes

    ST 425-5 (ST 2048-1) Quad-link 3G-A (1) 2SI,SQ 4096 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 48p, 47.95p Yes

    ST 425-5 (ST 2036-1) Quad-link 3G-B (1) 2SI,SQ 3840 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p Yes

    ST 425-5 (ST 2048-1) Quad-link 3G-B (1) 2SI,SQ 4096 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 48p, 47.95p Yes

    ST 2081-11 M1,ST 425-5 (ST 2036-1)

    Dual-link 6G-2SI (I) 3840 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p Yes

    ST 2081-11 M1,ST 425-5 (ST 2048-1)

    Dual-link 6G-2SI (I) 4096 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 48p, 47.95p Yes

    ST 2082-10 M1,ST 425-5 (ST 2036-1)

    12G-2SI (I) 3840 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p Yes

    ST 2082-10 M1,ST 425-5 (ST 2048-1)

    12G-2SI (I) 4096 x 2160 4:2:2 (YCbCr) 10 60p, 59.94p, 50p, 48p, 47.95p Yes

    Supported SDI standards

    This version of software supports the following standards:

    Please contact PHABRIX if you required support for any standards not listed here.

    Getting StartedPackage ContentsGeneral SafetyAvoiding Personal InjuryPower Supply

    How to upgrade softwareInstallation EnvironmentOperating TemperatureInput/Output TerminalsWhen Not In UseMaintenance

    RoHS ComplianceDisposal of EquipmentIcon display and meaning

    OverviewStart upInstallationAnalyser SDI connectionsGenerator SDI connectionsPowering up the QxMenu selectionInstrument Launch Menu

    Instrument DescriptionGenerator - ConfigurationPathological signal insertionOutput offset adjustment

    Generator - StatusSystem IO (SDI)Analyser - ConfigurationStats - SDI In A, B, C, DAnalyser - Picture Blanking AreaHDR Heat-map (False Colour Overlay)Transfer Curve and Colourimetry Overrides

    Analyser - CIE ChartAnalyser - WaveformAnalyser - VectorscopeEye - SDI in A (PHQX-01E only)Jitter - SDI In A (PHQX-01E only)Analyser - DataviewTiming and System ReferenceSystem Reference LockSDI A vs System ReferenceInput Measurement OffsetSDI Co-Timing

    Analyser - Ancillary StatusAnalyser - Audio MetersAnalyser - CRC AnalysisEvent LoggingNetwork StatusREST API Requests

    Time and NTPSpecificationsOn-going DevelopmentSupported SDI standards