[email protected] @ EPFL, 14.10.05

Design and first Prototype

for

a

Beam Pipe Distance Monitoring Safety Switch

[email protected] @ EPFL, 14.10.05

Requirements :

• Reliability of the system

„Fail-safe“ system

Simple principle of operation

• As little as possible additional material

As a careful touching of the beam pipe is permitted ....

[email protected] @ EPFL, 14.10.05

Beam Pipe Distance Monitoring both during installation and data taking

Top- and BottomBoxes

Side Boxes

Minimum distance : 7 mm !!

[email protected] @ EPFL, 14.10.05

First switch activated at 7 mm distance from the beam pipe signalSecond switch activated at 6.5 mm distance from the beam pipe alarm

Three switches under & at the front of the detector box

Three switches on top & at the front of the detector box

One switch at the side of the detector box

Each switch consistsOf two mettalic blades,Allowing a distance-Dependent signal

[email protected] @ EPFL, 14.10.05

Metall blade („finger strip“) :

Thickness 500 micronsBeryllium CopperSwitching precision < 0.250 mm

Foil around the beam pipe :

Thickness 100 micronsCopper

[email protected] @ EPFL, 14.10.05

Safety Switch for side boxes

Metallic foil

Stesalite piece & non magnetic blade

[Design model]

[email protected] @ EPFL, 14.10.05

Safety switch for top (and bottom) boxes

Metallic foil

Stesalite piece & non magnetic blade

[Design model]

[email protected] @ EPFL, 14.10.05

Next steps ...

Furhter tests with different finger strips

Detailed studies on electrical connection possibilities

Studies on optimal fixation points (on the detector boxes)