PERFORMANCE OF THE PERFORMANCE OF THE PHENIX SOUTH MUON ARM PHENIX SOUTH MUON ARM Kenneth F. Read Kenneth F. Read Oak Ridge National Lab Oak Ridge National Lab & University of Tennessee & University of Tennessee for the PHENIX Collaboration for the PHENIX Collaboration Quark Matter 2002 Quark Matter 2002 Nantes, France Nantes, France July 2002 July 2002

Upload: joann

Post on 06-Jan-2016

33 views

Category:

Documents


4 download

DESCRIPTION

PERFORMANCE OF THE PHENIX SOUTH MUON ARM. Kenneth F. Read Oak Ridge National Lab & University of Tennessee for the PHENIX Collaboration Quark Matter 2002 Nantes, France July 2002. PERFORMANCE. OF THE PHENIX. SOUTH MUON ARM. PHENIX MUON ARMS. North muon arm being - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

PERFORMANCE OF THEPERFORMANCE OF THEPHENIX SOUTH MUON ARMPHENIX SOUTH MUON ARM

Kenneth F. ReadKenneth F. Read

Oak Ridge National LabOak Ridge National Lab

& University of Tennessee& University of Tennessee

for the PHENIX Collaborationfor the PHENIX Collaboration

Quark Matter 2002Quark Matter 2002

Nantes, FranceNantes, France

July 2002July 2002

Page 2: PERFORMANCE OF THE PHENIX SOUTH MUON ARM
Page 3: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

PHENIX MUON ARMSPHENIX MUON ARMS

South muon identifier (MuID)5 gaps per arm filled with planes of transversely oriented Iarocci tubes

South muon tracker (MuTR)3 octagonal stations of cathode stripchambers per arm

North muon arm being

commissioned this summer

Page 4: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

MUON IDENTIFIERMUON IDENTIFIER

Small panel

Large panel

The South Muon Identifier

Page 5: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

MUON TRACKERMUON TRACKER

Installing a station 2 octant

into the south magnet

Winding anode wires

for a station 3 octant

Station 3 octants already installed

Station 2 octant under construction

Page 6: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

Cathode strips1 cm pitch

Gap 3, +11.25°

STRUCTURE OF A STATIONSTRUCTURE OF A STATION

momentum kick

Internal alignment <25 microns

Gap 2, +6.0°

Gap 1, -11.25°

Anode wire

direction

Cathode planeAnode plane

Cross Section of Station 1

98 mm

6 cathode planes

Page 7: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

NOISE PERFORMANCENOISE PERFORMANCE

Station 1 = 1.5-2.0 ADC

Station 2 = 2.0-4.0 ADC

Station 3 = 1.5-4.0 ADC

Noise goal = 2 ADC counts (indicated by )

The average noise per channel is already at this level.

Further improvement anticipated for next year.

Cathode strip charge for MIP peak ~200 ADC counts

2

2

2

2

preamp

64 cell AMU

ADC

cathode

Page 8: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

TRACKER CHAMBER ALIGNMENTTRACKER CHAMBER ALIGNMENT

Optical alignment system has 7 sets of straightness monitors per octant. Can correct for changes in alignment due to temperature or magnetic field.

Straight tracks from p+p field off data are used to accurately align chambers.

Projection errors at station 3

(for a typical half-octant) for

p+p field-off data. Precisely

centered at zero.

Note projection error includes

extrapolation over ~2 m and

does not directly indicate

intrinsic chamber resolution.

(See next page.)

Page 9: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

Performance of Production ChambersPerformance of Production Chambers

Composite chamber plus projectionerror of 131 microns is consistentwith 100 micron specification for thisproduction chamber octant.

Residuals for track stub projections within station 1 after installationusing p+p field-off data are betterthan 100 microns.

Resolution goal: 100 microns

work i

n pr

ogre

ss!

cm

work in

progress

100 m

Station 1 Track Stub Residuals

cm

Station 2 Octant Test Resolution

Page 10: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

CHANNEL-BY-CHANNEL EFFICIENCIESCHANNEL-BY-CHANNEL EFFICIENCIES

Identifier road projecting to struck

strips in tracker for cosmic ray event

interation

point

small muon

identifier panels

strips in stations 3, 2, 1.

Cosmic ray tracks are used to measure the

efficiency of each pair of muon identifier tubes. The distribution is broadened due to

insufficient statistics.

Page 11: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

ACTIVE MUON TRACKER CHANNELSACTIVE MUON TRACKER CHANNELS

Visualization of active regions of three tracking stations. Dead regions are due to problems with HV and front end modules during

2001-2 run. Majority of problems corrected for next run.

Station 3 Station 1Station 2 Interaction

point

Page 12: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

COLLISIONS!COLLISIONS!

Muon Tracker Multiplicity vs. Beam-Beam countertotal charge (a measure of multiplicity)

Au+Au data

Tracker occupancy increases with multiplicityas expected.

PHENIX sampled 24 b-1 of Au+Au data and 150 nb-1 of p+p data in Run 2 (2001-2).

Page 13: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

DIMUON CANDIDATEDIMUON CANDIDATE

Interaction point

3 stations of muon tracker

2 muon candidates penetrate muon identifier panels

Dimuon candidate from

p+p collision (rotated for

clarity with beam line

running vertically)

Page 14: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

OCCUPANCYOCCUPANCY

Hit

s/ev

ent

Muon Identifier gap

Occupancy as a function of depth in identifier

Occupancy observed in muon identifier for data agrees closely with expectations from simulation gap-by-gap. Occupancy generally decreases with depth in the identifier. The small increase for last gap is due to secondaries striking material in the square hole and is consistent with expectations from simulation.

Page 15: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

MUON IDENTIFIER LEVEL-1 TRIGGERMUON IDENTIFIER LEVEL-1 TRIGGER

NIM Logic LVL-1 Trigger used during 2001-2NIM Logic LVL-1 Trigger used during 2001-2 LVL-1 rejection is not required for Au+Au until RHIC

significantly exceeds design luminosity. LVL-1 rejection is required for lighter species, notably

p+p Used for stand-alone cosmic ray (diagnostic) trigger 4 gaps in trigger, each with 2 orientations. Trigger

required hits in 6 out of 8 gap/orientations per quadrant.

Use gaps 0,2,3,4. One MLU per quadrant.

Page 16: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

MUON LEVEL-2 TRIGGERMUON LEVEL-2 TRIGGER

Available LVL-2 requirements:Available LVL-2 requirements: minimum polar angle of muon(s) (12° or 15°) opening angle between two muons centrality of event (measured by PHENIX) For Run 3: match to station 3 of the muon tracker For Run 3: require minimum invariant mass of dimuon

pair! Efficient for muons from the vertex, good Efficient for muons from the vertex, good

rejection of hadronsrejection of hadrons

Trigger Name Rejection Factor

DiMuon 44DiMuonPeripheral 570

SingleMuon 7SingleMuonPeripheral 56

Measured rejection factors

Page 17: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

0.1

1

10

100

1000

10000

100000BBLL1

NTC

MUID1D1S

MUD1D

MUD1D-COSMIC

TR

IGG

ER

RA

TE

(H

z)

collimate beam

mis-steer

collimator out

TIME

dump yellow

blue target in

yellow target in

collimate blue

BACKGROUND STUDIESBACKGROUND STUDIES

After * = 1 m achieved, significant non-collision background observed. Studied problem with help from RHIC during p+p running by mis-steering beam and seeing panel currents remain high. Rates very sensitive to beam scrape. Collimation helps tremendously. RHIC expects to further investigate and improve this situation.

Page 18: PERFORMANCE OF THE PHENIX SOUTH MUON ARM

OUTLOOKOUTLOOK

The south muon arm performed well during its The south muon arm performed well during its first (2001-2) run and is producing physics first (2001-2) run and is producing physics results.results.

See related posters by D.-J. Kim, J. Newby, M. See related posters by D.-J. Kim, J. Newby, M. Liu, and H. Sato.Liu, and H. Sato.

For more information see www.phenix.bnl.gov.For more information see www.phenix.bnl.gov. The north muon arm will be commissioned this The north muon arm will be commissioned this

summer and fall.summer and fall.