performance of lc3 concrete - university of cape...

31
www.LC3.ch Performance of LC 3 Concrete Manu Santhanam Department of Civil Engineering, IIT Madras Workshops on Limestone Calcined Clay Cements Cape Town, Nov 19, 2019

Upload: others

Post on 19-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

www.LC3.ch

Performance of LC3 Concrete

Manu Santhanam

Department of Civil Engineering, IIT Madras

Workshops on Limestone Calcined Clay Cements

Cape Town, Nov 19, 2019

Page 2: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Mixture variables

» Materials used

» Limestone Calcined Clay Cement (LC3)

» OPC 53 grade cement

» Fly ash – Class F

» Design Mixes

» Grades M30 (residential) and M50 (infra)

» Common mix with w/b - 0.45 and total binder - 360 kg/m3

» Target slump: 80-120 mm

Page 3: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Concrete Mix Design

Sl.

NoMix I.D. w/b

CementFly

ash

Water

content

Fine

aggregate

Coarse

aggregate

SP

dosage (% wt. of

cement kg/m3

1 OPC-M30 0.50 310 0 155 695 496 744 0.02

2 FA30-M30 0.45 217 93 140 723 491 737 0.65

3 LC3-M30 0.50 310 0 155 708 491 736 1.00

4 OPC-M50 0.40 360 0 144 703 477 716 0.65

5 FA30-M50 0.35 266 114 133 699 475 713 0.60

6 LC3-M50 0.40 340 0 136 704 488 732 0.85

7 OPC-C

0.45

360 0 162 721 463 694 0.10

8 FA30-C 252 108 162 721 463 694 0.23

9 LC3-C 360 0 162 721 463 694 0.36

LC3 compared to OPC: Similar binder content and w/b

LC3 compared to FA30: Lower binder content and higher w/b for same grade

Higher SP requirement for LC3 concrete – expected

Page 4: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Evolution of compressive strength

Strength development characteristics for LC3 concretes matched

with OPC concrete, and were better than fly ash based concrete in

the early ages

LC3-50(56)(2:1)1B

Page 5: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Shrinkage of concrete

C-Mix

Page 6: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Surface resistivity

Resistivity of LC3 concretes was an order of magnitude higher than OPC (and also

significantly higher than PPC) which suggests better resistance to corrosion

propagation.

Page 7: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

by RCPT (ASTM C1202)

• There is a marked

improvement of the

chloride resistance at

an early age

irrespective of the

different grades of

concrete, unlike fly ash

based PPC system

which requires

additional curing at

higher water-binder

ratios.

Red- 28 days Blue- 90 days

Chloride penetrability

Page 8: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

by NT BUILD 492

• Results shown for

mixture with same

binder content and w/b

• Tested at 28 days after

different curing regime

shows very low

chloride migration

coefficients – similar to

high performance

silica fume concrete!

Also, lesser

dependence on

curing…

Chloride migration

Page 9: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Influence of field curing

RC slabs subjected to field like curing

using Hessian cloth for 14 days after

which slab was exposed to environment

Binder systemSpecimen

details

Total charge

passed

(Coulombs)

Non-steady

state

diffusion

coefficient

( x 10-12

m2/s)

LC3

Field

specimens160 1.77

Lab

specimens120 1.98

PPC (Fly ash; 25 %

replacement from

Srinivasan et al.

(2013))

Field

Specimens3050 12.50

Lab

specimens1800 8.20

Page 10: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

• Tortuous pore

structure has

reduced sorptivity in

the LC3 system;

FA30 system also

has a relatively

lower sorptivity

compared to the

OPC mix

Water sorptivity

Page 11: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Water sorptivity – secondary absorption

OPC FA30 LC33.0E-04

4.0E-04

5.0E-04

6.0E-04

7.0E-04

8.0E-04

9.0E-04

Ab

so

rpti

on

rate

(m

m/s

qrt

. s

)Secondary absorption rate as a measure of moisture ingress was found to

be positively affected due to refined pore structure in LC3 binder

Page 12: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Cummulated Pore Volume Vs Pore diameter of LC3 (w/c: 0.4)

Pore Diameter ( m)

0.00 0.01 0.10 1.00 10.00 100.00

Cu

mm

ula

ted

po

re v

olu

me

(m

m3/g

)

0

50

100

150

200

250

LC3 C- 3 DAYS

LC3 S- 3 DAYS

LC3 C- 7 DAYS

LC3 S- 7 DAYS

LC3 C- 28 DAYS

LC3 S- 28 DAYS • LC3 shows lowered threshold diameter

even as early as at 3 days

• Refined pore structure major factor for

better durability performance at early

ages

Cummulated Pore Volume Vs Pore diameter of FA30 (w/c: 0.4)

Pore Diameter ( m)

0.00 0.01 0.10 1.00 10.00 100.00

Cu

mm

ula

ted

po

re v

olu

me (

mm

3 /

g)

0

50

100

150

200

250

FA30 C-3 DAYS

FA30 S -3 DAYS

FA30 C-7 DAYS

FA30 S-7 DAYS

FA30 C-28 DAYS

FA30 S-28 DAYS

Pore structure evolution in LC3

Cummulated Pore Volume Vs Pore diameter of OPC (w/c: 0.4)

Pore Diameter ( m)

0.00 0.01 0.10 1.00 10.00 100.00

Cu

mm

ula

ted

po

re v

olu

me

(m

m3/g

)

0

50

100

150

200

250

OPC- C 3 DAYS

OPC- S 3 DAYS

OPC- C 7 DAYS

OPC- S 7 DAYS

OPC- C 28 DAYS

OPC- S 28 DAYS

Page 13: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

No expansion in LC3 and FA30 mortars even after more than 70 weeks of

exposure; OPC mortars show very high expansion

Length change as per ASTM C1202 LC3-50(56)(2:1) IB

T0 = Day 7

Sodium sulphate solution Magnesium sulphate solution

Sulphate Attack

Page 14: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Progression of chloride transport characteristics with time

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

FA

30

-F

IB v

alu

e

OPC

FA30

LC3Ag

ein

g c

oe

ffic

ien

t fr

om

Dn

ssm

Ageing coefficient from Eletrical conductivity

as per Andrade et al. (2011)

OP

C -

FIB

va

lue

OPC FAF CC Slag

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Ag

ein

g c

oeff

icie

nt

A(t

)

• Ageing coefficient is important for long term assessment of chloride induced corrosion

performance – service life estimation for performance-based design approaches

• Calcined clay concrete has similar ageing to slag and lesser than fly ash concrete

Page 15: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Chloride profiles of the M30 and M50 grade of concrete

(ASTM C1556) – Error Function solution – Diffusion

coefficient

Chloride Diffusion

M30 M50 C-Mixes

Page 16: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Evolution of carbonation depth in accelerated carbonation

with respect to time in concrete grade M30 and M50

• Concrete elements cast with LC3 show lower carbonation resistance at similar

strength grade in comparison with concretes made with OPC and FA30.

• Reason for lower carbonation resistance can be attributed to the lowered buffer

capacity of calcium bearing hydrated compounds

1 % CO23 % CO2

Carbonation

Page 17: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Natural Carbonation Results – Unsheltered exposure

• After two years of exposure concrete specimens cast with LC3 showed

higher carbonation than other cementitious systems at similar strength

grades

Page 18: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Natural Carbonation Results – Sheltered exposure

• Carbonation depth in sheltered exposure is greater than unsheltered

exposure due to relatively lesser micro climate variation

Page 19: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

What does this mean for corrosion?

Corrosion Initiation

• Better chloride binding → lesser risk of chloride induced corrosion

initiation

• Greater rate of carbonation → greater risk of corrosion initiation

Corrosion propagation

• Higher resistivity → reduced ionic conductivity, therefore reduced

rate of corrosion propagation

• Better microstructure development → reduced moisture availability,

therefore reduced rate of corrosion propagation

Let us now see how the performance can be translated to service life

in a chloride environment...

But first, we also need to know the Chloride Threshold levels...

Page 20: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

»Measured by detecting the change in polarization resistance

»Test Variables

»OPC ,FA30, LC3 Cementitious System; Mortar 1:2.75

»QST Steel (8 mm dia)

»Prestressing steel- king wire (5.2 mm dia)

Lollipop

Test Specimen

00

.51

1.5

22

.53

TMT -OPC PS -OPC TMT-FA30 PS -FA30 TMT -LC3 PS -LC3

Ch

lorid

e th

resh

old

(%

bw

oc)

µ - 1.45 1.22 1.08 1.06 0.55 0.56

COV - 32.15 12.45 38.83 18.39 42.71 34.40

LC3 system has less chloride threshold when compared to OPC and

FA30 systems.

Chloride Threshold

Page 21: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Test variables Constants used

Clear cover, x 50 mm

Chloride diffusion coefficient,

DCl

M50 grade concretes

• OPC : 21.8 x 10-12 m2/s

• FA30: 7.8 x 10-12 m2/s

• LC3 : 6.6 x 10-12 m2/s

Chloride threshold, Clth • OPC : 0.44 %bwoc

• FA30 : 0.32 %bwoc

• LC3 : 0.17 %bwoc

Maximum chloride conc. at

the concrete surface, Cs, max

Cs, max = 3 % bwoc

(0.6 % by wt. of concrete)

Surface chloride concentration

build up rate (%)0.04

Time for complete hydration

(years)25

Courtesy: L&T Ramboll

% bwoc → % by weight of cement

Typical element of a bridge

girder in India

Estimation of Service Life

Page 22: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Service life ranking considering concretes of same strength grades

For M50 → FA30 > LC3 >> OPC

(Point to consider: FA30 mix has lower w/b)

Page 23: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Effects of short term heat curing

Three binder proportionsOPC

FA30 (70% OPC + 30% Fly ash)

LC3 ( 55% OPC + 45% LC2)

Two concrete mixture proportions Binder content: 360 kg/m3 and w/b –

0.45

Binder content: 400 kg/m3 and w/b –

0.40

Experiments carried outConcrete strength evolution up to 90

days

Concrete Resistivity

Pore structure alteration due to steam

curing using MIP (Paste: w/b – 0.4)

X ray diffraction for phase changes

Page 24: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

1 7 280

10

20

30

40

50

60

70

400-0.4

Co

mp

res

siv

e s

tren

gth

(M

Pa)

Age (days)

LC3 - SC

LC3 - NC

Compressive Strength

Normal cured Vs Steam cured

1 7 280

10

20

30

40

50

Co

mp

res

siv

e s

tre

ng

th (

MP

a)

Age (days)

OPC - SC

OPC - NC

360-0.45

1 7 280

10

20

30

40

50

360-0.45

Co

mp

res

siv

e s

tren

gth

(M

Pa)

Age (days)

FA30 - SC

FA30 - NC

1 7 280

10

20

30

40

50

360-0.45

Co

mp

res

siv

e s

tre

ng

th (

MP

a)

Age (days)

LC3 - SC

LC3 - NC

1 7 280

10

20

30

40

50

60

70

Co

mp

res

siv

e s

tre

ng

th (

MP

a)

Age (days)

OPC - SC

OPC - NC

400-0.4

1 7 280

10

20

30

40

50

60

70

400-0.4

Co

mp

res

siv

e s

tren

gth

(M

Pa)

Age (days)

FA30 - SC

FA30 - NC

• Early increase in strength noticed with OPC and LC3

• Difference in 28 days strength due to short term heat curing is less than

10-15% for OPC and LC3 compared to moist cured concrete

• Fly ash concrete negligible rise in early strength and limited change 28

days strength

Page 25: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Strength evolution subjected to short-term heat cured concrete

1 7 28 900

10

20

30

40

50

60

70

Co

mp

ressiv

e S

tren

gth

(M

Pa)

Age (days)

OPC - SC

FA30 - SC

LC3 - SC

360-0.45

1 7 28 900

10

20

30

40

50

60

70

400-0.4

Co

mp

ressiv

e S

tren

gth

(M

Pa)

Age (days)

OPC

FA30

LC3

• No stagnation of strength was found in OPC, FA30 and LC3 concrete

• Strength up to 7 days were similar for OPC and LC3 – the difference were

higher at later ages

Page 26: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

• Short term heat curing reduces the

pore sizes dominantly in LC3

• Fly ash have limited effect on the

pore structure due to steam curing

- Explains minimal change in

strength development

1-d pore structure alteration due to heat curing

0.001 0.01 0.1 1

0

100

200

300

400

dV

/dlo

g(D

)

Pore diameter (m)

OPC - Normal cured 1 day

OPC - Steam cured 1 day

0.001 0.01 0.1 1

0

100

200

300

400

dV

/dlo

g(D

)

Pore diameter (m)

FA30 - Normal cured 1 day

FA30 - Steam cured 1 day

0.001 0.01 0.1 1

0

100

200

300

400

dV

/dlo

g(D

)

Pore diameter (m)

LC3 - Normal cured 1 day

LC3 - Steam cured 1 day

Page 27: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Change in durability indices due to heat curing

NC SC NC SC

OPC

360-0.45 w/b 400-0.4 w/b

0

20

40

60

80

100

120

140

Su

rfa

ce

Re

sis

tiv

ity

(K

oh

m.c

m)

Mean ± 1.5 SE

Median Line

NC SC NC SC

FA30

360-0.45 w/b 400-0.4 w/b

0

20

40

60

80

100

120

140

Su

rfa

ce R

es

isti

vit

y (

Ko

hm

.cm

)

Mean ± 1.5 SE

Median Line

NC SC NC SC

LC3

360-0.45 w/b 400-0.4 w/b

0

20

40

60

80

100

120

140

Su

rfa

ce R

es

isti

vit

y (

Ko

hm

.cm

)

Mean ± 1.5 SE

Median Line

• 28 days resistivity value reduced marginally for all binders subjected to heat

curing – the difference was rather insignificant

Page 28: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Phase change due to short term heat curing

10 15 20 25

Ettr.CHEttr.

OPC - NC

2- Thetha

OPC - SC

FA30 - SC

FA30 - NC

LC3 - SC

LC3 - NC

Ettr. Mc1 days

• Ettringite and Mc phase are diminishing due to heat curing

• Acceleration of calcined clay reaction is confirmed by CH consumption

Page 29: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Summary of results on short term heat curing

Initial strength gain after steam curing followed the orderOPC>LC3>FA30

Strength development up to 90 days was not affected due to

short-term heat curingStrength development rate were different for three binders.

OPC>LC3>>FA30

Ultimate strength reduction after short-term heat cured for OPC, FA30

and LC3 were less than 15%

No stagnation of strength development due to reduced clinker content

or enhanced reactivity of calcined clay was notice in concrete

Pore structure was studied after short-term heat curing.LC3>>OPC>FA30

Resistivity as durability indices showed minor reduction. However, the

reduction was rather limited

Page 30: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Conclusions

Limestone-calcined clay ternary systems show good

strength development at early ages, and result in

superior pore structure characteristics.

Resistance to chloride penetration is much better with LC3

concretes as opposed to OPC – at long term, fly ash

concretes and LC3 concretes are similar

Carbonation of LC3 is higher than fly ash concrete, but this

is mainly because of higher replacement levels of the

cement – high resistivity and low moisture penetration

may be beneficial in restricting corrosion propagation

Possible to use LC3 in heat cured concrete without any

negative effects

Page 31: Performance of LC3 Concrete - University of Cape Townwebcms.uct.ac.za/.../images/333/Downloads/Performance-of-LC3-Concr… · Concrete Mix Design Sl. No Mix I.D. w/b Cement Fly ash

Thank you

Support from SDC is gratefully acknowledged

31