15PC 18 Right to alterations reserved ii

Dampers .......................................................................................................................................................01

Circular Cut-Off Damper CFD ................................................................................................................02

Rectangular Cut-Off Damper RFD .......................................................................................................03

Automatic Fire Dampers FDA ...............................................................................................................04

Cut-Off Damper COD ...............................................................................................................................06

Cut-Off Dampers GFD ..............................................................................................................................07

Noise Damping Fan Sockets NDS ........................................................................................................08

Smoke Dampers SD ..................................................................................................................................09

FDA Fire Damper Adaptor Pieces ........................................................................................................10

Non-Return Flaps NRV .............................................................................................................................11

Diffuser Louvre Damper ADR ................................................................................................................12

FDB2 ...............................................................................................................................................................13

General FDB2 Module Assembly .........................................................................................................15

FDB2 ...............................................................................................................................................................16

FDO .................................................................................................................................................................17

FDO-PNR Pneumatic Diagram ..............................................................................................................23

UTG Shut Off, Balancing And Gas Damper .......................................................................................24

UTK, UTT Airflow Dampers ....................................................................................................................26

INDEX

Page 3: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 01

DAMPERSDampers

Page 4: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 02

CIRCULAR CUT-OFF DAMPER CFDCIRCULAR CUT-OFF DAMPER CFD

Page 5: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 03

RECTANGULAR CUT-OFF DAMPER RFDRECTANGULAR CUT-OFF DAMPER RFD

Page 6: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 04

AUTOMATIC FIRE DAMPERS FDAAUTOMATIC FIRE DAMPERS FDA

Page 7: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 05

AUTOMATIC FIRE DAMPERS FDAAUTOMATIC FIRE DAMPERS FDA

Page 8: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 06

CUT-OFF DAMPER CODCUT-OFF DAMPER COD

Page 9: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 07

CUT-OFF DAMPERS GFDCUT-OFF DAMPERS GFD

Page 10: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 08

NOISE DAMPING FAN SOCKETS NDSNOISE DAMPING FAN SOCKETS NDS

Page 11: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 09

SMOKE DAMPERS SDSMOKE DAMPERS SD

Page 12: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 10

FDA FIRE DAMPER ADAPTOR PIECESFDA FIRE DAMPER ADAPTOR PIECES

Page 13: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 11

NON-RETURN FLAPS NRV

NON-RETURN FLAPS NRV

Page 14: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 12

DIFFUSER LOUVRE DAMPER ADRDIFFUSER LOUVRE DAMPER ADR

Page 15: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 13

3

FDB2 - A0(A60) Fire And Gas Damper

Halton FDB2 fire dampers are type-approved class

A0(A60) fire and gas dampers for use in offshore, marine

and navy ventilation systems. The FDB2 can be installed

in rectangular or circular ducts. All fire dampers have a

fusible link and they prevent the spread of fire and gases

within the ventilation ductwork. When the blades are in

the open position, the device does not cause significant

pressure loss, noise or flow disturbance. Fire dampers

are set from outside and can be installed in any position.

An open-closed indicator is visible on the outside of the

damper. Fire dampers with non-standard dimensions

can be supplied on request.

•Type-approved by most recognized classification

societies: class A0 without insulation, A15-A60 when

suitably insulated

•Available as ATEX approved. Shock tested.

•Blades contain silicone (effective up to 300 ºC)

for low leakage in normal conditions and thermal

expansion graphite seals (effective from 150 ºC) to

increase tightness even up to 50% in a case of fire.

Closed damper fulfills the requirement of leakage

class 3 (EN1751:1998). Tested size 1000x1000 mm.

•Nominal fuse release temperature 50 ºC, 74 ºC

or 100 ºC. Other temperatures available.

•Low weight due to patented double skin blade

structure

•Automatic electrical, pneumatic or spring operation

system available

•Maximum duct pressure for damper construction

5000 Pa and maximum air velocity 15 m/s

PART MATERIAL FINISHING

Frame Carbon steel Painted or galvanised

Frame Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) -

Blades Steel Galvanized

Blades Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) -

Maintenance-free bearings Stainless steel EN 1.4404 (AISI316L) / Option: bronze bearings available -

Shafts Stainless steel EN 1.4404 (AISI316L) -

FDB2A0(A60) Fire And Gas Damper

This FDB2 has been customized with the following options: NORSOK flanges, control enclosure, ATEX certified components and steel tubing

FDB2

Page 16: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 14

4

FDB2 - A0(A60) Fire And Gas Damper

ACTUATOR DIMENSIONS

R A

Electrical GGA 326.1E 100 H<300 = 300 H>300 = H

Pneumatic PNL

Linear actuator 245/300 N

170 H<500 = 500 H>500 = H

Pneumatic PNR

Pneumatic rotating actuator AT100

170 H<300 = 300 H>300 = H

Pneumatic PNR

Pneumatic rotating actuator AT200

190 H<350 = 350 H>350 = H

Spring Spring 140 H

FDB2 DIMENSIONS AND MATERIAL THICKNESS

FDB2 fire dampers meet international standards for

both rectangular (width B 100-1200 mm and height

H 100-1600 mm, 1 mm division) and circular ducts

(Ø100-1250 mm). Modular constructions are available

for bigger sizes (as an example 2400x3200 mm). Non-

standard dimensions and flange drilling available on

request. Standard flange width 27 mm. Flanges and

drilling also available according to ISO 15138 standards.

Frame thickness 3-5 mm according to SOLAS. Also

6, 8 and 10 mm frame thicknesses are available on

request.

ø12

10

MIN. 50

H+5

8

B+58

150

n*15

0n*

150

150

150

n*150n*150

150

10

10

10B+4

H+4

R30

MIN

. 50

18

A

AC

TUAT

OR

GENERAL FDB2 DRAWING

Actuator effect in dimensions

GENERAL FDB2 DRAWING, TOP

S, A

CCO

RDIN

GTO

SO

LAS

215,

S=5

212,

S=4

210,

S=3

160

240,

BLA

DES

IN O

PEN

PO

SITI

ON

FDB2 CIRCULAR CONNECTIONS

361, S=3

S, A

CC

ORD

ING

TO

SO

LAS

365, S=4

370, S=5

ØD

DIMENSIONS S L

If B or H > 100, but < 449 3 210

If B or H > 450, but < 649 4 212

If B or H > 650 5 215

Frame thickness according to SOLAS

The above table contains only some examples of actuators and their effect on dimensions.

367, S=3

373, S=4

380, S=5

S, ACC

ORDI

NG TO

SOLA

S

ØD

FDB2 CIRCULAR, WITH CONNECTION FLANGES

FDB2

Page 17: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 15

5

FDB2 - A0(A60) Fire And Gas Damper

V5M

07Y

2013

/Hal

ton

Mar

ine

rese

rves

th

e ri

gh

t to

alt

er p

rod

uct

s w

ith

ou

t n

oti

ce.

H/Height B / Width (mm)

mm 100 200 300 400 500 600 700 800 900 1000 1100 1200 D2 ØD Weight100 5 (5) 7 (7) 9 (9) 10 (10) 12 (13) 14 (15) 15 (22) 17 (25) 19 (27) 20 (30) 22 (32) 24 (35) mm kg200 7 (7) 9 (9) 11 (11) 12 (12) 14 (16) 16 (18) 18 (26) 20 (28) 22 (31) 23 (34) 25 (36) 27 (39) 100 8 (8)300 9 (9) 11 (11) 13 (13) 15 (15) 17 (19) 19 (21) 21 (30) 23 (32) 25 (35) 27 (38) 29 (41) 31 (43) 125 8 (8)400 11 (11) 13 (13) 15 (15) 17 (17) 20 (22) 22 (24) 24 (33) 26 (36) 28 (39) 30 (42) 32 (45) 34 (48) 160 12 (12)500 13 (16) 16 (19) 18 (22) 21 (25) 23 (27) 25 (30) 28 (38) 30 (41) 32 (44) 35 (47) 37 (50) 39 (54) 200 13 (13)600 15 (18) 18 (21) 20 (24) 23 (27) 25 (30) 28 (33) 30 (41) 33 (45) 35 (48) 38 (51) 40 (55) 43 (58) 250 19 (19)700 18 (25) 21 (28) 23 (32) 26 (35) 29 (39) 32 (42) 34 (46) 37 (50) 40 (53) 42 (57) 45 (60) 48 (64) 315 20 (20)800 20 (27) 23 (31) 25 (35) 28 (38) 31 (42) 34 (46) 37 (50) 40 (53) 43 (57) 46 (61) 49 (64) 51 (68) 400 27 (27)900 22 (31) 25 (35) 28 (39) 32 (42) 35 (46) 38 (50) 41 (54) 44 (58) 47 (62) 50 (66) 53 (70) 56 (74) 500 35 (43)

1000 24 (33) 27 (37) 31 (41) 34 (45) 37 (50) 40 (54) 44 (58) 47 (62) 50 (66) 53 (70) 57 (74) 60 (78) 630 46 (62)1100 26 (36) 30 (41) 33 (45) 37 (49) 40 (54) 44 (58) 47 (62) 51 (67) 54 (71) 58 (75) 61 (79) 65 (84) 800 62 (89)1200 28 (39) 32 (44) 36 (48) 39 (52) 43 (57) 46 (61) 50 (66) 54 (70) 57 (75) 61 (79) 65 (84) 68 (88) 1000 83 (118)1300 31 (42) 35 (47) 38 (52) 42 (56) 46 (61) 50 (66) 54 (70) 58 (75) 62 (80) 65 (84) 69 (89) 73 (94) 1250 113 (162)1400 32 (45) 37 (50) 41 (55) 45 (59) 49 (64) 53 (69) 57 (74) 61 (79) 65 (84) 69 (88) 73 (93) 77 (98)

(Frame thickness

according to SOLAS)1500 35 (48) 39 (53) 43 (58) 48 (63) 52 (68) 56 (73) 60 (78) 65 (83) 69 (89) 73 (94) 77 (99) 82(104)1600 36 (51) 41 (56) 45 (61) 50 (66) 54 (72) 59 (77) 63 (82) 67 (87) 72 (92) 76 (98) 81 (103) 85 (108)

FDB2 PRODUCT OPTIONS

Halton FDB2 is available with following actuators:

•FDB2-EL: Electrical spring return motor; standard

actuators being 24 V or 230 V or 120 V. The motor

contains built-in open-closed limit switches. Separate

junction box included in the EL-model. A wide range

of eex-proof actuators available, including a one

second closing time function as an option.

•FDB2-PNL: Pneumatic linear actuator,

material stainless steel

•FDB2-PNR: Pneumatic rotating actuator

•FDB2-SP: Manual spring-actuated damper with

fusible link

DOT: manual override function available for PNL, PNR

and EL models. A wide range of accessories available.

OPERATION PRINCIPLE

In the event of a temperature rise in ductwork:

•FDB2-EL: fusible link releases and cuts off operating

voltage to the spring return motor, allowing the

spring to close the damper blades. The fire damper

opens automatically when the fuse has been

changed and the operating voltage to the motor is

re-established.

•FDB2-PNL, FDB2-PNR: fusible link releases and cuts

off operating pressure to the spring return actuator,

allowing springs to close the damper blades. The

fire damper opens automatically when the fuse

has been changed and the pneumatic air supply is

re-established.

•FDB2-SP: fusible link releases allowing the spring to

close the damper blades. When the fuse has been

changed, the fire damper must be reset into open

position manually.

WEIGHTS OF STANDARD HALTON MARINE FDB2 DAMPERS (KG) without an actuator

Examples of actuator weights: FDB2-EL GGA 326.1E 2,3 kg, GNA 326.1E 1,3 kg, BF230 +3,2 kg, BLF230 +1,7 kg, ExMax/Redmax +3,5 kg, CSQP +3 kg , FDB2-PNL Roder +4 kg, FDB2-PNR AT100 +2,1 kg, AT100 as AISI316 4,4 kg, AT200 +3,2kg, AT200 as AISI316 +6,2 kg, FDB2-SP +1 kg. Control enclosure +4 kg.

BOLTED FROM

DETAIL I

BOTH SIDES

B+58 FDB2

H+5

8 FD

B2

10.0 FDB2

10.0

FD

B2

9.0 FDL

9.0

FDL

B+56 FDL

H+5

6 FD

L

max. FDB2 1200

max. FDL 1300

max

. FD

B2

1600

max

. FD

L 12

00

AC

TUAT

OR

AC

TUAT

OR

AC

TUAT

OR

AC

TUAT

OR

S

L

I

FLAT BAR STEEL

FLAT BAR CROSS STEEL

2.0

M10*20 8.8

FLAT BARS TO BE SEALED WITH PYROCRYL SEALANTØ 12.0

GENERAL FDB2 MODULE ASSEMBLY

GENERAL FDB2 MODULE ASSEMBLY

Page 18: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 16

6

FDB2 - A0(A60) Fire And Gas Damper

FDB2-EL WIRING DIAGRAMS FDB2-PNR/PNL PNEUMATIC DIAGRAM

SPRING RETURNACTUATOR

VALVESQUICK EXHAUST

VALVEFUSIBLE LINK

3 PORT/2 WAY

1

2

4

8

6

6

6

3

3

9

3 PORT/2 WAYSOLENOID VALVE

PNEU. INLET (5 - 8 BAR)

PIPELINES:POLYAMIDE

OPTION:5

6

6

3

6

6

10

3 PORT/2 WAYMANUAL VALVE

3

LIMIT SWITCHES

OPTION:

3

21 13

22 14 1422

21 13 OPENCLOSED

7

OPTION:

PRESSURE REGULATOR

24/220 V

8

8

8

6

6

FOR A PLASTIC TUBEØ6 MM

SPEED CONTROLLER

1. SPRING RETURN VALVE

2. QUICK EXHAUST VALVE

3. SILENCER

4. FUSIBLE LINK VALVE

5. OPTION: SOLENOID VALVE

6. MALE CONNECTOR

7. DOUBLE NIPPLE

8. PLASTIC TUBE. OPTION: STAINLESS STEEL

9. OPTION: OPEN / CLOSED SWITCHES

10. OPTION: MANUAL VALVE

11. PRESSURE REGULATOR

12. SPEED CONTROLLER

11

12

85°

109

24....230 VAC/DC

OPTION: 50/74/100°CFUSIBLE LINK

Schischek

(+)(-)

IP 665°

JUNCTION BOX

1211 13

~ ~

BLA

CK

BLU

E

BR

OW

N

2 3 5 1 4PE S1 S3S2 S5 S6S4

PE

(BARTEC)

1

M20M20

M20 M20

PE

CLOSED AND OPENEDINFORMATION OUT

1486 732 4 5

PE 32 15 S14 S5S3S2 S4 S6BK BE BN

M20

151 2 3 4 5 6 7 8

S6S5S4S3S2

M 87°

109

THERMAL FUSESM-072-A0-2A (72°C)

OPTION: 50/74/100°CFUSIBLE LINK

AC24V

(+)(-)

IP 54

S1

JUNCTION BOX

11

DC24...48VDAMPERCLOSED

DAMPEROPEN

M16 M16 M16

M20 M16

(+)

(-)

S6S5S4S3S2S1

1 2 3 4

1 2 3 4

2(4)

1(3)

2(4)

1(3)

SIEMENSGGA.126.1E/HAGGA226.1E/HAGGA326.1E/HAGNA126.1E/HAGNA326.1E/HA

AC120VAC230V

1 2 3 4 5 6 7 8

S6S5S4S3S2

M 87°

109

THERMAL FUSESM-072-A0-2A (72°C)

OPTION: 50/74/100°CFUSIBLE LINK

AC24V

(+)(-)

IP 543°

S1

JUNCTION BOX

11

DC24...48VDAMPERCLOSED

DAMPEROPEN

M16 M16 M16

M20 M16

(+)

(-)

S6S5S4S3S2S1

1 2 3 4

1 2 3 4

1 2

1 2

BELIMOBF24 / BF120 / BF230BLF24 / BLF230

AC120VAC230V

FDB2

Page 19: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 17FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

.

Halton FDO fire dampers are type-approved class A0(A60)

fire dampers for use in marine and offshore ventilation

systems. The FDO can be installed in circular ducts. All

fire dampers have a fusible link and they prevent the

spread of fire within the ventilation ductwork. When the

blade is in the open position, the device does not cause

significant pressure loss, noise or flow disturbance. Fire

dampers are set from outside and can be installed in

any position. An open-closed indicator is visible on the

outside of the damper.

•Type-approved by most recognized classification

societies, class A0 - A60 fire damper when suitably

insulated

•Fixed frame of painted, galvanized or stainless

steel. Blades stainless or galvanized steel. Flanges

available as an option.

•Blade contains seals (effective up to 270 ºC)

•Nominal fuse release temperature 50 ºC, 74 ºC

or 100 ºC. Other temperatures available.

•Very low leakage

•Automatic electrical, pneumatic or spring operation

system available

•Maximum duct pressure for damper construction

5000 Pa and maximum air velocity 15 m/s

FDOA0(A60) Fire Damper

PART MATERIAL FINISHING

Frame Carbon steel Painted or galvanised

Frame Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) -

Blades Steel Galvanized

Blades Stainless steel EN 1.4301 (AISI304), EN 1.4404 (AISI316L), EN 1.4432 (AISI316L) -

Maintenance-free bearings Stainless steel EN 1.4404 (AISI316L) -

Shafts Stainless steel EN 1.4404 (AISI316L) -

FDO in picture with flanges (available as an option)

FDO

Page 20: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 18

A

B

I

C

ØDE

I

F GG

T

3

Damper BladeAlt. positionof the actuator

H

A

C

I

I

FG G

T

Alt. Positionof the actuator

H

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

. FDO DIMENSIONS AND MATERIAL THICKNESS

FDO fire dampers meet international standards for

circular ducts (Ø100-500 mm). Sizes Ø100 and Ø125

are not available of stainless steel. Sizes starting from

GENERAL FDO DRAWING (without flanges)

FDO DRAWING (with flanges)

Ø160 can be manufactured with 1 mm division. Flanges

and drilling available as an option and according to ISO

15138 standards. Special flanges and drilling available on

request. Frame material thickness according to SOLAS.

FDO

Page 21: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 19

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

.

FDO weight without flanges

Size ØD (mm) KG

100 4125 5160 4,5200 7,5250 9315 12400 17500 22,5

WEIGHTS OF STANDARD HALTON MARINE FDO DAMPERS (KG) without an actuator

Weights stated above do not include flanges or any actuator.Examples of actuator weights: FDO-EL CSQP +3,5 kg, BF230 +3,2 kg, BLF230 +1,7 kg, ExMax or RedMax or InMax +3,5 kg, FDO-PNR AT100 (AISI) +6,2 kg, AT50 (AISI) +3 kg, FDO-SP +1 kg.

FDO Dimensions with flanges (as an option)FDO-EL FDO-PNR FDO-SP

Dampersize

Inside dimensions

Bolt circle

Outside dimensions

Material thickness

Bolt holes

Bolt holes Qty

Housing Lenght

Blade Elodrive CSQP/Schischek

Belimo BF

Air Torque AT 50

Spring

Ø A B C T D E F G H I H I H I H I100 100,8 120 200 3,6 8,5 4 206 - 150 200 115 200 135 105 150 115125 125 150 225 4 8,5 4 206 - 150 200 115 200 135 105 150 115160 160 185 260 3 8,5 4 206 - 150 200 115 200 135 105 150 115200 200 225 300 3 8,5 4 326 - 150 200 115 200 135 105 150 115250 250 280 350 3 12 4 326 - 150 200 115 200 135 105 150 115315 315 355 415 3 12 8 326 - 150 200 115 200 135 105 150 115400 400 450 500 3 12 8 326 40 150 200 115 200 135 105 150 115500 500 560 600 3 12 12 326 90 150 200 115 200 135 105 150 115

FDO Dimensions without flanges (standard)FDO-EL FDO-PNR FDO-SP

Dampersize

Inside dimensions

Outside dimensions

Materialthickness

Housing Lenght

Blade Elodrive CSQP/Schischek

Belimo BF

Air Torque AT50

Air Torque AT100

Spring

Ø A C T F G H I H I H I H I H I100 100,8 108 3,6 200 - 150 200 115 200 145 215 165 215 150 115125 125 133 4 200 - 150 200 115 200 145 215 165 215 150 115160 160 166 3 200 - 150 200 115 200 145 215 165 215 150 115200 200 206 3 320 - 150 200 115 200 145 215 165 215 150 115250 250 256 3 320 - 150 200 115 200 145 215 165 215 150 115315 315 321 3 320 - 150 200 115 200 145 215 165 215 150 115400 400 408 4 320 43 150 200 115 200 145 215 165 215 150 115500 500 508 4 320 93 150 200 115 200 145 215 165 215 150 115

FDO weight with flanges

Size ØD (mm) KG

100 5125 6,5160 6200 9,5250 11315 14,5400 17500 22,5

FDO

Page 22: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 20

qv [dm³/s]

pst

[Pa]

3 5 1010 20 30 50 100100 2005

1010

2030

50

100100

200300

50017 33 50 67 83

100

30

40

50

60

FDO 100

qv [dm³/s]

pst

[Pa]

5 1010 20 30 50 100100 2005

1010

2030

50

100100

200300

50017 33 50

67

83100

30

40

50

60

FDO 125

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

.

FDO PRESSURE DROP AND SOUND LEVELS

Size ØD (mm) Closed blade leakage Casing leakage

100 2 C125 2 C160 3 C200 3 C250 3 C315 3 C400 3 C500 3 C

FDO LEAKAGE CLASS ACCORDING TO STANDARD EN1751

FDO PRODUCT OPTIONS

Halton FDO is available with following actuators:

•FDO-EL: Electrical spring return motor; standard

actuators being 24 V or 230 V or 120 V. The motor

contains built-in open-closed limit switches. Separate

junction box included in the EL-model. A wide range

of eex-proof actuators available, including a one

second closing time function as an option.

•FDO-PNR: Pneumatic rotating actuator

•FDO-SP: Manual spring-actuated damper with fusible

link

DOT: manual override function available for PNR models.

A wide range of accessories available.

OPERATION PRINCIPLE

In the event of a temperature rise in ductwork:

•FDO-EL: fusible link releases and cuts off operating

voltage to the spring return motor, allowing the

spring to close the damper blades. The fire damper

opens automatically when the fuse has been

changed and the operating voltage to the motor is

re-established.

•FDO-PNR: fusible link releases and cuts off

operating pressure to the spring return actuator,

allowing springs to close the damper blades. The

fire damper opens automatically when the fuse

has been changed and the pneumatic air supply is

re-established.

•FDO-SP: fusible link releases allowing the spring to

close the damper blades. When the fuse has been

changed, the fire damper must be reset into open

position manually.

FDO

Page 23: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 21

qv [dm³/s]

pst

[Pa]

10 20 30 50 100100 200300 500 10005

1010

2030

50

100100

200300

50017 33 50 67

83

100

30

40

50

60

FDO 160

qv [dm³/s]

pst

[Pa]

10 20 30 50 100100 200300 500 10005

1010

2030

50

100100

200300

50017 33 50 67

83

100

30

40

50

60

FDO 200

qv [dm³/s]

pst

[Pa]

10 20 30 50 100100 200300 500 10005

1010

2030

50

100100

200300

50017 33 50 67

83

100

40

50

60

FDO 250

qv [dm³/s]

pst

[Pa]

20 30 50 100100 200300 500 10001000 20005

1010

2030

50

100100

200300

50017 33 50 67

83

100

40

50

60

FDO 315

qv [dm³/s]

pst

[Pa]

50 100100 200 300 500 10001000 200030005

1010

2030

50

100100

200300

50033 50 67

83

100

40

50

60

FDO 400

qv [dm³/s]

pst

[Pa]

100 200 300 500 10001000 20003000 50003

5

1010

2030

50

100100

200300

33 50 67

83

100

40

50

60

FDO 500

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he r

ight

to

alte

r pr

oduc

ts w

ithou

t no

tice.

FDO

Page 24: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 22

FDO-EL WIRING DIAGRAM with Belimo actuator

FDO-EL WIRING DIAGRAM with ExMax or RedMax

actuator

3 x 0,75 mm²

WHEN DAMPER IS NOT ENERGIZEDCONTACTS S1-S2, S4-S6 ARE CLOSED

6 x 0,5 mm² 6 x 0,5 mm²

M20 M20

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

PE -E

ART

HIN

G R

AIL

EN

D C

LA

MP

EN

D C

LA

MP

BK GY BN 2 3 5 1 4 1 2 3 4 5 6PE

(+) (-)(PE) 1 2 3 4

POWER SUPPLY24-230V AC/DCL/+ N/- PE

M20M20M20

FUS

IBLE

LIN

K

BK

GY

BN

DAMPERCLOSED

DAMPEROPEN

2 3 41

PE 2 3 45 1 4 31 2

5 6

85°IP 66

ExMax-15-SF

HEATER

RedMax-15-SF

FUSI

BLE

LIN

K 50

/74/

100°

C

14

13

1 2 3 4

EN

D C

LA

MP

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

PE2 3 5

1 2 3 4 5 6

PE 1 2 3 4

PE

PE

1

1

1 4

EN

D C

LA

MP

(+) (-)

13 14

PE(+) (-)~ ~

PE 2 3 45 1 4 31 2

5 6

85°IP 66

InMax-15-SF

HEATERWHEN DAMPER IS NOT ENERGIZEDCONTACTS S1-S2, S4-S6 ARE CLOSED

6 x 0,5 mm² 6 x 0,5 mm²

M16 M16

M20

M16

M16

SIHF2 x 0,75 mm²

DAMPERCLOSED

DAMPEROPEN24-230 V AC/DC

FDO-EL WIRING DIAGRAM with InMax actuator

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

.

M16

S2 S3 S4 S5 S6S113 14

M20

M16M16

1 2 3 4

M16

EN

D C

LA

MP

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

1

1

11

11

EN

D C

LA

MP

1 2 3 4(-)(+)

(+) (-)

FUSIBLE LINK 74°C14

13

SIHF2 x 0,75 mm²

12

IP 545° 80°

S1 S2 S3 S4 S5 S6BELIMO

21BF24BF230BF120BLF24BLF230

DAMPERCLOSED

DAMPEROPEN

POWER SUPPLY120 V AC

MWHEN DAMPER IS NOT ENERGIZEDCONTACTS S1-S2, S4-S5 ARE CLOSED

2 x 0,75 mm² 6 x 0,75 mm²

FDO-EL WIRING DIAGRAM with Elodrive CSQP

13 14

EN

D C

LA

MP

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

1

1

11

11

EN

D C

LA

MP

NL

L N

32 1

FUS

IBLE

LIN

K14

13

SIHF

2 x 0

,75

mm

²

M16 M16M16

M16

M20

IP66

ELODRIVE CSQP-15A1E

21 3

N L1

T-

~+

15A2E10A1E10A2E05A2E05A2E

POWER SUPPLY120/230 V AC

3 x 0,75 mm²

FDO

Page 25: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 23

FDO-PNR PNEUMATIC DIAGRAM

FDO - A0(A60) Fire Damper

V1/

M01

Y20

15. H

alto

n M

arin

e re

serv

es t

he

rig

ht

to a

lter

pro

du

cts

wit

ho

ut

no

tice

.

SPRING RETURNACTUATOR

VALVESQUICK EXHAUST

VALVEFUSIBLE LINK

3 PORT/2 WAY

1

2

4

8

6

6

6

3

3

9

3 PORT/2 WAYSOLENOID VALVE

PNEU. INLET (5 - 8 BAR)

PIPELINES:POLYAMIDE

OPTION:5

6

6

3

6

6

10

3 PORT/2 WAYMANUAL VALVE

3

LIMIT SWITCHES

OPTION:

3

21 13

22 14 1422

21 13 OPENCLOSED

7

OPTION:

PRESSURE REGULATOR

24/220 V

8

8

8

6

6

FOR A PLASTIC TUBEØ6 MM

SPEED CONTROLLER

1. SPRING RETURN VALVE

2. QUICK EXHAUST VALVE

3. SILENCER

4. FUSIBLE LINK VALVE

5. OPTION: SOLENOID VALVE

6. MALE CONNECTOR

7. DOUBLE NIPPLE

8. PLASTIC TUBE. OPTION: STAINLESS STEEL

9. OPTION: OPEN / CLOSED SWITCHES

10. OPTION: MANUAL VALVE

11. PRESSURE REGULATOR

12. SPEED CONTROLLER

11

12

85°

109

24....230 VAC/DC

OPTION: 50/74/100°CFUSIBLE LINK

Schischek

(+)(-)

IP 665°

JUNCTION BOX

1211 13

~ ~

BLA

CK

BLU

E

BR

OW

N

2 3 5 1 4PE S1 S3S2 S5 S6S4

PE

(BARTEC)

1

M20M20

M20 M20

PE

CLOSED AND OPENEDINFORMATION OUT

1486 732 4 5

PE 32 15 S14 S5S3S2 S4 S6BK BE BN

M20

151 2 3 4 5 6 7 8

S6S5S4S3S2

M 87°

109

THERMAL FUSESM-072-A0-2A (72°C)

OPTION: 50/74/100°CFUSIBLE LINK

AC24V

(+)(-)

IP 54

S1

JUNCTION BOX

11

DC24...48VDAMPERCLOSED

DAMPEROPEN

M16 M16 M16

M20 M16

(+)

(-)

S6S5S4S3S2S1

1 2 3 4

1 2 3 4

2(4)

1(3)

2(4)

1(3)

SIEMENSGGA.126.1E/HAGGA226.1E/HAGGA326.1E/HAGNA126.1E/HAGNA326.1E/HA

AC120VAC230V

1 2 3 4 5 6 7 8

S6S5S4S3S2

M 87°

109

THERMAL FUSESM-072-A0-2A (72°C)

OPTION: 50/74/100°CFUSIBLE LINK

AC24V

(+)(-)

IP 543°

S1

JUNCTION BOX

11

DC24...48VDAMPERCLOSED

DAMPEROPEN

M16 M16 M16

M20 M16

(+)

(-)

S6S5S4S3S2S1

1 2 3 4

1 2 3 4

1 2

1 2

BELIMOBF24 / BF120 / BF230BLF24 / BLF230

AC120VAC230V

FDO-PNR PNEUMATIC DIAGRAM

Page 26: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 2425

UTG equipped with pneumatic actuator, junction box and solenoid valve

UTG - Shut-off, Balancing And Gas Damper

UTG

Shut-off, Balancing And Gas Damper

Halton UTG dampers are used to shut-off and balance

airflow rates in high pressure ductwork. Dampers meet

international standards for rectangular and round ducts.

In the open position, the blades face the direction of

flow and do not cause a significant pressure loss.

The UTG is used as a shut-off, gas and balancing damp-

er in applications where tightness and reliability are im-

portant.

•For shut-off and balancing of air intake and exhaust

•ATEX approved. Shock tested

•Closed damper fullfils the leakage requirement of

NORSOK. Leakage class of closed damper according

to prEN 1751 class 3 (tested size 1000x1000 mm

VTT test report no. RTE4302/04)

•Outer frame of galvanized, painted or stainless steel.

Blades of galvanized or stainless steel with double

sheet construction, silicon sealings. Maintenance-

free stainless steel bearings and shafts

•Electrical, pneumatical or manual operation system

available

•UTG dampers can be supplied with connection

pieces for round duct

•Maximum duct pressure for damper construction

5000 Pa and maximum air velocity 15 m/s. In case of

high duct pressure, contact Halton Marine for finding

the most suitable solution.

PART MATERIAL FINISHING NOTE

Frame Carbon steel Painted or galvanized -

Frame Stainless steel - -

Blades Steel Galvanized -

Blades Stainless steel - -

Maintenance-free bearings Stainless steel - Bronze bearings available as option

Shafts Stainless steel - -

UTG SHUT OFF, BALANCING AND GAS DAMPER

Page 27: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 2526

UTG - Shut-off, Balancing And Gas Damper

UTG DIMENSIONS AND MATERIAL THICKNESS

UTG shut-off, gas and balancing dampers meet

international standards for both rectangular (width

B 100-1200 mm and height H 100-1600 mm, 1 mm

division) and circular ducts (Ø100-1250 mm). Non-

standard dimensions are available on request.

Standard flange width 27 mm. Flanges and drilling also

available according to ISO 15138 standards. Modular

construction sizes available up to 2400X3200 mm.

Frame thickness 3 mm.

Ø12

10

MIN. 50

H+5

8

B+58

150

n*15

0n*

150

150

150

n*150n*150

150

10

10

10

B+4

H+4

R30

MIN

. 50

18

A

AC

TUAT

OR

GENERAL UTG DRAWING

Actuator effect on dimensions

GENERAL UTG DRAWING, TOP

3

210

160

240,

BLA

DES

IN O

PEN

PO

SITI

ON

UTG CIRCULAR CONNECTIONS

361

ØD

WEIGHTS OF STANDARD HALTON MARINE UTG DAMPERS (KG) without an actuator

367

ØD

UTG CIRCULAR, WITH CONNECTION FLANGES

H / Height B / Width (mm)

mm 100 200 300 400 500 600 700 800 900 1000 1100 1200 D2 ØD Weight100 4 6 7 9 10 12 13 15 16 17 19 20 mm kg200 6 8 9 11 13 14 16 17 19 21 22 24 100 7300 8 10 12 14 15 17 19 21 22 24 26 28 125 8400 10 12 14 16 18 20 22 23 25 27 29 31 160 11500 13 15 17 19 21 23 25 28 30 32 34 36 200 12600 15 17 19 21 24 26 28 30 33 35 37 39 250 17700 17 20 22 25 27 29 32 34 37 39 42 44 315 19800 19 22 24 27 29 32 35 37 40 43 45 48 400 26900 21 24 27 30 33 36 38 41 44 47 50 53 500 34

1000 23 26 29 32 35 38 41 44 47 50 53 56 630 441100 26 29 32 35 38 42 45 48 51 55 58 61 800 591200 27 31 34 37 41 44 48 51 54 58 61 64 1000 801300 30 33 37 41 44 48 51 55 58 62 66 69 1250 1101400 32 35 39 43 47 50 54 58 61 65 69 731500 34 38 42 46 50 54 58 62 66 70 74 771600 36 40 44 48 52 56 60 65 69 73 77 81

Examples of actuator weights: UTG-EL GGA 326.1E 2,3 kg, GNA 326.1E 1,3 kg, BF230 +3,2 kg, BLF230 +1,7 kg, ExMax /Redmax +3,5 kg, UTG-PNR AT100 +2,1 kg, AT100 as AISI316 4,4 kg, AT50 1,2 kg, UTG-PNL Roder +4 kg, UTG-MAN + 1 kg.

ACTUATOR DIMENSIONS

R A

Manual Handle 95 H

Electrical GGA 326.1E 100 H<300 = 300H>300 = H

Pneumatic PNL

Linear actuator 245/300 N

170 H<500 = 500H>500 = H

Pneumatic PNR

Pneumatic rotating actuator AT100

170 H<300 = 300H>300 = H

The above table contains only some examples of actuators and their effect on dimensions.

UTG SHUT OFF, BALANCING AND GAS DAMPER

Page 28: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 2627

UTK, UTT - Airflow Dampers

V4M

05Y

2010

/Hal

ton

Mar

ine

rese

rves

th

e ri

gh

t to

alt

er p

rod

uct

s w

ith

ou

t n

oti

ce.

UTK, UTT

•Temperature operation range up to +100°C,

optionally up to +200°C.

•Classification of casing leakage EN 1751 class B

UTK

•Shut-off, adjustment, balancing, adjustment or control

damper with opposed blade construction

•Tightness in closed position fulfills EN 1751 class 1

requirements

UTT

•Shut-off and balancing damper for outdoor air intake

and exhaust air with opposed blade design

•Damper blades comprise thermal insulation

•Tightness in closed position fulfills EN 1751 class 4

requirements (tested size 600x600 mm)

Product models and Accessories

•Model with stainless steel (AISI 316) design

•Model with mineral wool (20 mm) insulated casing

•Model with heat-proof design

•Circular duct connections

•Several actuator options

PART MATERIAL NOTE

Casing Galvanised steel Stainless steel AISI 316 also available

Blades (sandwich design) Galvanised steel Stainless steel AISI 316 also available

Blade insulation (only UTT) Polyurethane CFC free

Blade gaskets Silicon Heat-proof model: LTE rubber

Gasket inside the casing (only UTT)

Silicon Fixed in an aluminium profile, Heat-proof model: LTE rubber

Duct gasket Rubber compound Circular connections

Slide bearings Alloy of polyamide and molybdenum sulphide

Self-lubricated Heat-proof model stainless steel AISI 316 also available

Drive shaft Galvanised steel Rectangular (15x15 mm) bar

UTK, UTT Airflow Dampers

UTK, UTT AIRFLOW DAMPERS

Page 29: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 27

28 29

UTK, UTT - Airflow Dampers

ØD WxH

100 150x150

125 150x150

160 200x200

200 200x200

250 250x250

315 300x300

400 400x400

500 500x500

630 600x600

800 800x800

1000 1000x1000

1250 1250X1250

DIMENSIONSCircular connections

UTK and UTT dampers are manufactured for both

rectangular (width B 100-2400 mm and height H

100-2400 mm, 1 mm division) and circular ducts

(Ø100-1250 mm). Special non-standard dimensions

and flange drilling available on request. Modular

construction sizes up to 4900x4900 mm are available.

Standard frame material thickness 1 mm.

GENERAL UTK, UTT DRAWING

GENERAL UTK, UTT DRAWING, CIRCULAR CONNECTIONS

8

20

H+4

H+4

4

B+44

B+4 210

15x1

5

26

100

B+20

H+2

0

14x10

ø12 UTT+D1UTT+D2

H+4

4

B+44

B+20

H+2

0

320 265

Page 30: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 28

28 29

UTK, UTT - Airflow Dampers

V4M

05Y

2010

/Hal

ton

Mar

ine

rese

rves

th

e ri

gh

t to

alt

er p

rod

uct

s w

ith

ou

t n

oti

ce.

THE ADJUSTMENT AND CONTROL OPTIONS

ADJUSTMENT & CONTROL OPTIONS CODE NOTE

Manual handle adjustment MO = MA

Manual extension bar adjustment AC = BA Handle extension arrangement

Flexible coupling bar AC = FS For remote actuator coupling

Actuator operation MO= A wide range of actuators available

UTK, UTT DRAWING, FLANGE CONNECTION

GENERAL UTK, UTT MODULE ASSEMBLY

27

H+4

H+5

8

B+58

B+4 210

15x1

5

19

100

B+40

H+4

0

14x10

210

15x1

5

100

27

B+58B+4

H+4

H+5

8

96

27

96

Page 31: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 29

30 31

UTK, UTT - Airflow Dampers

Function, UTK and UTT

The UTK dampers are used to shut off, adjust or

control airflow in ductwork in applications where

damper leakage does not have significant importance.

In the closed position the UTK damper leakage class is

1 in accordance with the EN1751 standard.

The UTT dampers are used to shut off or control

airflow in ductwork where tightness, thermal

insulation and reliability are important. In the closed

position the UTT damper leakage class is 4 in

accordance with the EN1751 standard (tested size

600x600 mm).

In the open position the blades are turned in the

direction of flow and do not cause significant pressure

losses.

Damper sizes conform with the international standards

EN 1505, EN1506 and ISO 1707 for rectangular and

circular ducts.

Heat transmission of the damper is 6 W/(m2K).

UTK UTT

Main parts

CODE DESCRIPTION

1 Casing

2 Blade

3 Gasket

4 manual adjustment handle / actuator platform

Install the damper in the ductwork with the blades

in horizontal or vertical position. Fasten the damper

in the ductwork using slip joints. Optional models

enable fastening the damper to duct flange by using

bolts. Drill holes in the damper flange if necessary.

Use a seal between the flanges in order to tighten the

seam. Fasten the circular connections by riveting or

screwing.

Installation

2000

1000

500

200

100

501 3 10 30 100 300 500 1000 2000

4 3 2 1

DIN 1946/4UTTUTSUTK

CLASS

Damper tightness

1

2

4

1

2

34

l/s/m2

Page 32: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 30

30 31

UTK, UTT - Airflow Dampers

V4M

05Y

2010

/Hal

ton

Mar

ine

rese

rves

th

e ri

gh

t to

alt

er p

rod

uct

s w

ith

ou

t n

oti

ce.

H/Height B / Width (mm)

mm 100 200 300 400 500 600 700 800 900 1000 1100 1200200 3 3 4 5 6 6 7 8 8 9 10 16300 4 5 6 6 7 8 9 9 10 11 12 18400 5 5 6 7 8 9 10 10 11 12 13 20500 5 6 7 8 9 10 11 12 13 14 15 21600 6 7 8 9 10 11 12 13 14 15 17 23700 7 8 9 9 11 12 13 15 16 17 18 25800 7 9 10 11 12 14 15 16 18 19 20 27900 8 9 11 12 13 15 16 18 19 20 22 291000 9 10 12 13 15 16 18 19 21 22 24 311100 9 11 13 14 16 17 19 20 22 24 25 321200 10 12 14 15 17 19 20 22 24 25 27 351300 11 13 14 16 18 20 22 23 25 27 29 361400 12 14 16 17 19 21 23 25 27 29 31 381500 12 14 161 18 20 22 24 26 28 30 32 401600 13 15 17 20 22 24 26 28 30 32 34 421700 14 16 18 20 23 25 27 29 31 34 36 441800 15 17 19 22 24 26 29 31 33 35 38 461900 15 18 20 22 25 27 30 32 34 37 39 472000 16 19 21 24 26 29 30 34 36 39 41 492100 17 19 22 25 27 30 32 35 38 40 43 512200 18 20 23 26 28 31 34 37 39 42 45 532300 18 21 24 27 29 32 35 38 41 44 46 552400 19 22 25 28 31 34 37 40 42 45 48 57

WEIGHTS OF STANDARD HALTON MARINE UTK DAMPERS (KG) without an actuator

H/Height B / Width (mm)

mm 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400200 17 17 18 21 21 22 23 25 26 27 27 28300 20 20 21 24 25 26 26 29 30 31 32 32400 21 22 23 26 27 27 28 31 32 33 34 35500 23 24 25 28 29 30 31 34 35 36 37 38600 25 26 27 31 32 33 34 37 38 39 40 41700 27 28 29 33 34 35 36 40 41 42 43 44800 29 31 32 35 37 38 39 43 44 45 47 48900 31 33 34 38 39 40 42 45 47 48 50 511000 34 35 37 40 42 43 45 49 50 52 53 551100 35 37 39 42 44 46 47 51 53 54 56 581200 38 40 41 45 47 49 51 54 56 58 60 621300 40 41 43 47 49 51 53 57 59 61 63 651400 42 44 46 50 52 54 56 60 62 64 66 681500 44 46 48 52 54 56 59 63 65 67 69 711600 46 48 51 55 57 59 62 66 68 70 73 751700 48 50 53 57 59 62 64 69 71 73 76 781800 50 53 55 60 62 65 67 72 74 77 79 821900 52 55 57 62 65 67 70 74 77 79 82 852000 55 57 60 65 67 70 73 78 80 83 86 882100 56 59 62 67 70 72 75 80 83 86 89 912200 59 62 65 70 73 76 78 83 86 89 92 952300 61 64 67 72 75 78 81 86 89 92 95 982400 63 66 69 75 78 81 84 89 92 95 99 102

UTK D1 UTK D2

D1 ØD Weight D2 ØD Weightmm kg mm kg160 4 160 4200 4 200 5250 5 250 6315 7 315 9400 9 400 11500 12 500 15630 16 630 21800 23 800 301000 32 1000 421250 51 1250 66

Page 33: PC 18 Fire Dampers and Shut o Dampers - AF Gruppen

15PC 18 Right to alterations reserved 31

32

UTK, UTT - Airflow Dampers

H/Height B / Width (mm)

mm 100 200 300 400 500 600 700 800 900 1000 1100 1200200 3 3 4 5 6 7 7 8 9 9 10 16300 4 5 6 7 7 8 9 10 11 11 12 19400 5 6 6 7 8 9 10 11 12 13 13 20500 5 6 7 8 9 10 11 12 13 14 15 22600 6 7 8 9 11 12 13 14 15 16 17 24700 7 8 9 10 11 13 14 15 16 18 19 26800 8 9 10 12 13 14 16 17 18 20 21 28900 8 10 11 12 14 15 17 18 20 21 23 301000 9 11 12 14 15 17 18 20 22 23 25 321100 10 11 13 15 16 18 20 21 23 25 26 341200 11 12 14 16 18 19 21 23 25 27 28 361300 11 13 15 17 19 21 22 24 26 28 30 381400 12 14 16 18 20 22 24 26 28 30 32 401500 13 15 17 19 21 23 25 27 30 32 34 421600 14 16 18 20 22 25 27 29 31 34 36 441700 14 16 19 21 23 26 28 30 33 35 38 461800 15 17 20 22 25 27 30 32 35 37 40 481900 16 18 21 23 26 28 31 34 36 39 41 502000 16 19 22 25 27 30 33 35 38 41 43 522100 17 20 23 25 28 31 34 37 39 42 45 542200 18 21 24 27 30 33 36 38 41 44 47 562300 19 22 25 28 31 34 37 40 43 46 49 582400 20 23 26 29 32 35 38 42 45 49 51 60

WEIGHTS OF STANDARD HALTON MARINE UTT DAMPERS (KG) without an actuator

H/Height B / Width (mm)

mm 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400200 17 17 18 21 21 22 23 25 26 27 27 28300 20 20 21 24 25 26 26 29 30 31 32 32400 21 22 23 26 27 27 28 31 32 33 34 35500 23 24 25 28 29 30 31 34 35 36 37 38600 25 26 27 31 32 33 34 37 38 39 40 41700 27 28 29 33 34 35 36 40 41 42 43 44800 29 31 32 35 37 38 39 43 44 45 47 48900 31 33 34 38 39 40 42 45 47 48 50 511000 34 35 37 40 42 43 45 49 50 52 53 551100 35 37 39 42 44 46 47 51 53 54 56 581200 38 40 41 45 47 49 51 54 56 58 60 621300 40 41 43 47 49 51 53 57 59 61 63 651400 42 44 46 50 52 54 56 60 62 64 66 681500 44 46 48 52 54 56 59 63 65 67 69 711600 46 48 51 55 57 59 62 66 68 70 73 751700 48 50 53 57 59 62 64 69 71 73 76 781800 50 53 55 60 62 65 67 72 74 77 79 821900 52 55 57 62 65 67 70 74 77 79 82 852000 55 57 60 65 67 70 73 78 80 83 86 882100 56 59 62 67 70 72 75 80 83 86 89 912200 59 62 65 70 73 76 78 83 86 89 92 952300 61 64 67 72 75 78 81 86 89 92 95 982400 63 66 69 75 78 81 84 89 92 95 99 102

UTT D1 UTT D2

D1 ØD Weight D2 ØD Weightmm kg mm kg160 4 160 4200 4 200 5250 5 250 6315 7 315 9400 9 400 11500 12 500 15630 17 630 21800 24 800 301000 33 1000 431250 52 1250 67