page 1 of 5 test report · 3) test standard: iso 20653-2013 4) test condition: 1. protection test...
TRANSCRIPT
![Page 1: Page 1 of 5 TEST REPORT · 3) Test Standard: ISO 20653-2013 4) Test Condition: 1. Protection test for dangerous parts: Use a rigid steel rod (1 mm diameter) push against any openings](https://reader033.vdocuments.mx/reader033/viewer/2022041704/5e43c544f097c0448b562fe7/html5/thumbnails/1.jpg)
Page 1 of 5
TEST REPORTClient : SHENZHEN GOTRON ELECTRONIC CO.,LTD
Address : 518,5F,R&D building,Tsinghua Hi-Tech Park, Nanshan district, Shenzhen
Sample Name : Mobile Phone
Sample Model : Armor 3T
Brand Name : Ulefone
Sample Quantity : 2PCS
Sample Received Date : Sep.05, 2018
Sample Tested Date : Sep.05, 2018-Sep.11, 2018
Test Standard : ISO 20653-2013
Test Result : IP69K Pass
Tested by
Guanyu Chen( Chen Guanyu) Sep.12, 2018
Reviewed by
KyleXiong(Xiong Zhi) Sep.12, 2018
Approved by
TaylorChen(ChenMeng)Authorized Officer
Sep.12, 2018
Attestation of Global Compliance(Shenzhen) Co., Ltd.
CAUTION:
The test report is effective only with both signature and specialized stamp. The result(s) shown in thisreport refer only to the sample(s) tested. Without written approval of AGC, this report can’t be reproducedexcept in full.
![Page 2: Page 1 of 5 TEST REPORT · 3) Test Standard: ISO 20653-2013 4) Test Condition: 1. Protection test for dangerous parts: Use a rigid steel rod (1 mm diameter) push against any openings](https://reader033.vdocuments.mx/reader033/viewer/2022041704/5e43c544f097c0448b562fe7/html5/thumbnails/2.jpg)
Report No:AGC004367180901SR01Report Version:V1.0
Page 2 of 5
TEST REPORTTest Item: IPX9K Test
1) Environment Conditions:
Temperature: 26.2℃ Humidity: 54% RH
2) Sample Information:
Sample No. Sample Name Sample Model Sample Quantity Remark
001 Mobile Phone Armor 3T 1PC /
3) Test Standard: ISO 20653-2013
4) Test Condition:
1. Distance between sample and nozzle: 150 mm;
2. Water temperature: 80℃;
3. Water flow: 15 L/min;
4.water pressure: 10000 kPa
5. Turntable speed: 5 r/min;
6. Hydraulic position: 0℃ and 30℃, 60℃ and 90℃;
7. Water spraying time: spray water at each position for 30 s, a total of 120 s.
5) Test Equipment:
Sequence Equipment Name Equipment No. Calibration DateNext Calibration
Date
1Box rain testchamber
IP-XK00-06 Apr. 13 , 2018 Apr. 12 , 2018
6) Test Results:
Sample No. TestResults Description Judgment
001After the test, the sample can be switched on normally, and there is no
water in the sample.Pass
![Page 3: Page 1 of 5 TEST REPORT · 3) Test Standard: ISO 20653-2013 4) Test Condition: 1. Protection test for dangerous parts: Use a rigid steel rod (1 mm diameter) push against any openings](https://reader033.vdocuments.mx/reader033/viewer/2022041704/5e43c544f097c0448b562fe7/html5/thumbnails/3.jpg)
Report No:AGC004367180901SR01Report Version:V1.0
Page 3 of 5
TEST REPORTSample Photos Before Test:
Sample Photos During Test:
Sample Photos After Test:
![Page 4: Page 1 of 5 TEST REPORT · 3) Test Standard: ISO 20653-2013 4) Test Condition: 1. Protection test for dangerous parts: Use a rigid steel rod (1 mm diameter) push against any openings](https://reader033.vdocuments.mx/reader033/viewer/2022041704/5e43c544f097c0448b562fe7/html5/thumbnails/4.jpg)
Report No:AGC004367180901SR01Report Version:V1.0
Page 4 of 5
TEST REPORTTest Item: IP6X Test
1) Environment Conditions:
Temperature:23℃ Humidity: 50%RH
2) Sample Information:
Sample No. Sample Name Sample Model Sample Quantity Remark
002 Mobile Phone Armor 3T 1PC /
3) Test Standard: ISO 20653-2013
4) Test Condition:
1. Protection test for dangerous parts:
Use a rigid steel rod (1 mm diameter) push against any openings of the enclosure, the test force is 1N
2. Dust test:
1) The sample is pumped at negative pressure, the volume of air is <40 times the volume of the shell per hour,
the pressure inside the sample shell and the pressure outside the shell are not more than 2KPa
2) The amount of talcum powder: 2kg/m3
3) The size of talcum powder: The talcum powder used shall be able to pass through a square-meshed sieve the
nominal wire diameter of which is 50 micron and the nominal width of a gap between wires 75 micron
4) Test duration: 8H
5) Test Equipment:
SequenceEquipmentName
Serial No.EquipmentModel
Calibration DateNext
Calibration Date
1 Dust Tester AGC-RE-E018 KXT1410 Jul.27, 2018 Jul.26, 2019
6) Test Results:
Sample No. TestResults Description Judgment
002After testing, the sample can be switched on normally, and no dust is detected
inside the sample.Pass
![Page 5: Page 1 of 5 TEST REPORT · 3) Test Standard: ISO 20653-2013 4) Test Condition: 1. Protection test for dangerous parts: Use a rigid steel rod (1 mm diameter) push against any openings](https://reader033.vdocuments.mx/reader033/viewer/2022041704/5e43c544f097c0448b562fe7/html5/thumbnails/5.jpg)
Report No:AGC004367180901SR01Report Version:V1.0
Page 5 of 5
TEST REPORTSample Photos Before Test:
Sample Photos During Test:
Sample Photos After Test:
*** End of Report ***
Testing laboratory address:1F., Building C West,Qinyu Industrial Park, Nanchang Community, Baoan Road, Xixiang